the introduction for rf diathermy device

36
THE INTRODUCTION for RF DIATHERMY DEVICE JAN. 12, 2009

Upload: glenna

Post on 01-Feb-2016

78 views

Category:

Documents


7 download

DESCRIPTION

THE INTRODUCTION for RF DIATHERMY DEVICE. Lavatron LVT-250 LVT-100. JAN. 12, 2009. What is RF diathermy?. Over 100KHz (High Frequency Current, HFC) Same as Radio Frequency Range → Radio Frequency → RF. Lavatron 420KHZ. RF diathermy History. 1886 Development of Radio Frequency Device. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: THE INTRODUCTION for  RF DIATHERMY DEVICE

THE INTRODUCTION for RF DIATHERMY DEVICE

JAN. 12, 2009

Page 2: THE INTRODUCTION for  RF DIATHERMY DEVICE

What is RF diathermy?

Over 100KHz (High Frequency Current, HFC)

Same as Radio Frequency Range → Radio Frequency → RF

Lavatron 420KHZ

Page 3: THE INTRODUCTION for  RF DIATHERMY DEVICE

RF diathermy History

1886 Development of Radio Frequency Device

1897 Approve the effect of Radio Frequency for Diabetes, Obesity

1899 Report the generating of heat in body tissues by passing RF

1906 Study for the break of tumor tissue by RF

1930 RF diathermy device development

Page 4: THE INTRODUCTION for  RF DIATHERMY DEVICE

RF Tumor Coagulation RF Lesion Generator

Short wave(10MHz) Diathermy device Physiotherapy Diathermy Treatment

Various RF Device

Page 5: THE INTRODUCTION for  RF DIATHERMY DEVICE

RF diathermy Principle

Patient plate

Monopolarelectrode

Transformation of Over 100KHz inside body Activation of Ion movement inside of body

Collision between Ion

Generate Core body temperature 40~50°C and 3~5CM depth

→ →

Page 6: THE INTRODUCTION for  RF DIATHERMY DEVICE

- Pole

420 KHZ = Ion inside of body moves 420,000 times movement / sec

+ Pole

Monopolar Type - Lavatron

•Current flows between two poles (Electrode and Patient plate).

Electrode is “+ Pole” and Patient plate is “– Pole”. Current flow from Electrode(+ Pole) to Patient Plate(- Pole).

In the mono polar, heat is generated in the deepest side of body comparing bipolar and tripolar type.

RF diathermy Principle

Page 7: THE INTRODUCTION for  RF DIATHERMY DEVICE

• It needs separate patient plate and electrode (one is electrode (+pole) and the other is patient plate (-pole)) and current flows between two poles. So the depth of penetration is the deepest among three type of RF.

• The generated heat damages the old collagen and accelerates the regeneration of new collagen by improved metabolism and supplying new nutrition on the body through RF treatment.

• Heat penetrates to the demise area so it melts the cellulite. It is effective to remove fat inside of the body as well.

• With this strong effect on body and face, you can expect visible result right after treatment in your body and face.

Monopolar Type - Lavatron

Page 8: THE INTRODUCTION for  RF DIATHERMY DEVICE

•+ pole and – pole are in one electrode.

•RF current flows between two poles like above picture. So the patient plate is not required.

• The depth of penetration is fixed and limited to approximately half of the distance between the two poles.

• This means, less energy of sufficient density reaches the deeper skin layers, rendering a more superficial effect regardless of the emitted energy level.

•It is effective on face to remove wrinkle and tightening but it can not touch the fat cell so it is not effective on body.

Bipolar Type

Page 9: THE INTRODUCTION for  RF DIATHERMY DEVICE

•One + pole and two – poles are in one electrode.

•RF current flows between 3 poles. So current flows between three poles and the penetration depth is a little bit deeper than bi-polar but its depth of penetration is shallower than mono polar RF.

•It touch on superficial area on the skin like bi polar RF. Its basic electricity principle is same with bipolar. With this reason, its result is also similar with bi polar. It is effective on face treatment but it is hard to expect good effect on the body especially removing cellulite.

Tripolar Type

Page 10: THE INTRODUCTION for  RF DIATHERMY DEVICE

HYPERTHERMIA

Capacitive Electrode Transfer

Lavatron CETLavatron CET

RETRET Resistive Electrode Transfer

Non conductive electrode

INDUCED CURRUNT –Guaranty the Safeness

Go into 3 to 5cm depth deep and wide part,

Good for skin and body care, pain relief

Conductive electrode

Direct CURRUNT – Go into deep but narrow part

Dangerous for burn and damage organ.

For physical therapy, need high power

Page 11: THE INTRODUCTION for  RF DIATHERMY DEVICE

Body Fat

combustion

Body Fat

combustion

Collagen

Re composition

Collagen

Re composition

Obesity Care Obesity Care

↓ ↓ ↓

Increasing blood flow rate

Expansion of artery and capillary

Increasing core body temperature up to 40~50℃

Biological effect of RF Diathermy

Increase in

O2 supply

Increase in

O2 supply

Increase in

Nutrition supply

Increase in

Nutrition supply

Stimulation of

Immune system

Stimulation of

Immune system

Increase in

Metabolism

Increase in

Metabolism

Removal of

Waste material

Removal of

Waste material

Treatment good for Beauty as well as Health

Page 12: THE INTRODUCTION for  RF DIATHERMY DEVICE

MAIN APPLICATIONS

FAT CONTROL

PAIN CONTROLWRINKLE REMOVING

HAIR RESTORTION BODY SHAPING

LIFTING

Page 13: THE INTRODUCTION for  RF DIATHERMY DEVICE

RF Diathermy Body care part

Body Fat Decomposition

Cellulite Dissolving

Size Decreasing

Lifting

Remove Stretch Marks

Abdominal fat care

Size decreasing

Abdominal fat care Before

Abdominal fat care After

Page 14: THE INTRODUCTION for  RF DIATHERMY DEVICE

Treatment Way -BODY

Lavatron

Meso-therapy

Endermology

Cool Pack

Synergy effect: Lifting, Sliming,

Page 15: THE INTRODUCTION for  RF DIATHERMY DEVICE

RF Diathermy treatment - Skin care Part

Skin Reproduction

Improvement Wrinkle removing

Relaxing stressed facial muscle

Stimulating Collagen lay

Dissolving Melanin pigment

Acne treatment by sebaceous glands

Facial size decreasing

Dark circle treatment

Crow’s feet removing

Collagen structure before treatment

Collagen structure after treatment

Page 16: THE INTRODUCTION for  RF DIATHERMY DEVICE

Collagen re composition

SKIN

Lavatron

Treatment

Lavatron

Treatment Aging Aging

Page 17: THE INTRODUCTION for  RF DIATHERMY DEVICE

Treatment Way - FACE

Lavatron

Meso-therapy

Vitamin C

Cool Pack

Synergy effect: Lifting, Sliming, Anti Aging

Synergy effect: Whitening, Anti Aging

Page 18: THE INTRODUCTION for  RF DIATHERMY DEVICE

Improvement of Crow’s feet

Lavatron Effect (Before & After) for Face

Improvement of Acne

Improvement of Age spot Improvement of Nasal folds

Page 19: THE INTRODUCTION for  RF DIATHERMY DEVICE

After 1 session treatment for 10 min. – 40 times magnified image

Crow’s Feet

Page 20: THE INTRODUCTION for  RF DIATHERMY DEVICE

After 1 session treatment for 10 min. – 40 times magnified image

Forehead

Page 21: THE INTRODUCTION for  RF DIATHERMY DEVICE

Medical application of RF Diathermy

Shoulder pain

Lumbar pain

Rheumatology

Heat’s deep penetration into tissue

Relaxing stressed muscle by overwork and bad position

Pain Relief

*Chronic arthritis *Muscle pain *Lumbar pain

*Rheumatic arthritis *Frozen shoulder

Application

Page 22: THE INTRODUCTION for  RF DIATHERMY DEVICE

RF Diathermy treatment - Hair Care Part

Before After

Supplying Oxygen to scalp

Stimulating hair root

Sterilization

Application

• Prevent alopecia, Hair growth, Seborrheic scalp care

Page 23: THE INTRODUCTION for  RF DIATHERMY DEVICE

Demodex

Hair scarp

Damage hair root, Eat the nutrient material

Hair and Demodex

Page 24: THE INTRODUCTION for  RF DIATHERMY DEVICE

Special feature of Diathermy Device Lavatron

Auto temperature control function(Patent number: 20-397295)

Auto temperature control function(Patent number: 20-397295)

Treatment lesion monitoring function(Patent number: 20-397295)

Treatment lesion monitoring function(Patent number: 20-397295)

Timer functionTimer function

Various electrode for each treatmentsVarious electrode for each treatments

Guaranty the most safe and effective treatment with below unique feature

Page 25: THE INTRODUCTION for  RF DIATHERMY DEVICE

Standard ACCESSARIES

100mm 80mm 70mm 60mm 50mm 40mm 30mm 20mm

Page 26: THE INTRODUCTION for  RF DIATHERMY DEVICE

Optional ACCESSARIES

Pain Relief Electrode-Put the ceramic electrode on the body

without moving.

-Effective for

1) Muscle Relaxation, Pain Relief

2) Promote blood Circulation

3) Increase the metabolism

4) Mind Relaxation

5) Discharge toxin and body wastes

6) Make the skin shining with health

7) Save the labor for rubbing

Page 27: THE INTRODUCTION for  RF DIATHERMY DEVICE

Optional ACCESSARIES

Hair Electrode- Press the hair electrode around 5 seconds

on the hair scalp. It is the unique electrode

for hair scalp

-Effective for

1) Accelerate blood circulation

2) Increase air supply on the hair scalp

3) Increase hair cream absorption rate

4) Kill the demodex

5) Physical massage effect

6) Evenly supply RF on the hair scalp in

between of hair with 24 points

Page 28: THE INTRODUCTION for  RF DIATHERMY DEVICE

Size(Diameter)

Appling part Effect Picture

20 ㎜ Wrinkle under eyes, nose, around mouth

Improve wrinkle

30 ㎜ Face, around Cheek and JawImprove wrinkle and skin

care

40 ㎜ Face, Neck, back of neck, arm Skin care and pain relief

50 ㎜ Arm, Calf, Shoulder, ChestBody care, Skin care, Pain

relief

60 ㎜ Calf, Thigh, Back, Chest Body care, Pain relief

70 ㎜ Back, Thigh, abdomenObesity, Body care, Pain

relief

80 ㎜ Back, Thigh, abdomenObesity, Body care, Pain

relief

100 ㎜ Back, Abdomen Obesity, Body care, Pain

relief

Various electrodes

Page 29: THE INTRODUCTION for  RF DIATHERMY DEVICE

SPECIFICATION

420KHZ

Page 30: THE INTRODUCTION for  RF DIATHERMY DEVICE

Accessories

LVT-100

Page 31: THE INTRODUCTION for  RF DIATHERMY DEVICE

Benefit:

-No pain, no side effects

-Remarkably safe and effective for all skin types

-No aftercare service required

Application: Stimulates collagen layer -> Remove fine wrinkle, Increase skin elasticity, Reduce pore size, Lifting

Reduce acne scar and remove acne

Reduce age spot

LVT-100

Page 32: THE INTRODUCTION for  RF DIATHERMY DEVICE

Special feature of Diathermy Device LVT-100

Auto temperature control function(Patent number: 20-397295)

Treatment lesion monitoring function

Timer function

Five kinds of electrode for treatments

(Patent number: 20-397295)

Temperature setting: 37℃~45℃

Page 33: THE INTRODUCTION for  RF DIATHERMY DEVICE

Special feature of Diathermy Device LVT-100

Error message be displayed in the LCD window

when the below case is occurred

Page 34: THE INTRODUCTION for  RF DIATHERMY DEVICE

SPECIFICATION LVT-100

ITEM Description

Main Power 100~240 V auto select

Output Power Max. 70W, Load 500Ω

Output Wave 470kHZ ± 10% Sine wave

Output Power adjust(Auto adjustable and Manual adjustable)

Auto

1 ~ 70 W Auto control

Manual

1 ~100 %(1%/step)

Output time Max. 30 Min.(1min/step)

Active electrodes Ф20 mm, Ф30 mm, Ф40 mmФ50 mm, Ф60 mm

Temperature adjust Auto: 37°C ~ 45°C (1°C step)

Page 35: THE INTRODUCTION for  RF DIATHERMY DEVICE

RF conductive cream

RF Face care cream

- Retinol: Wrinkle improve

- Adenoisine: Increase elasticity of collagen fiber

- Aloe liquid: High Skin Moisture effect`

RF body cream

- Caffeine: Body fat combustion, Body care

- Aloe liquid: High Skin Moisture effect, Increase metabolism

Page 36: THE INTRODUCTION for  RF DIATHERMY DEVICE

EuropeEurope

*Italy*Italy

*Spain*Spain

*Portugal*Portugal

*Poland*Poland

*Turkey*Turkey

*Russia*Russia

*Slovenia*Slovenia

*U.S.A*U.S.A

*Mexico*Mexico

*Canada*Canada

*Guatemala*GuatemalaMiddle EastMiddle East

*Iran*Iran

*Egypt*Egypt

U.A.EU.A.E

AsiaAsia

*Hong Kong*Hong Kong

*Thailand*Thailand

*Myanmar*Myanmar

SingaporeSingapore

MalaysiaMalaysia

JapanJapan

ChinaChina

IndonesiaIndonesia

TaiwanTaiwan

KazakhstanKazakhstan

Export 20 countries

Under Process

*: Exclusive Distributor