tests & modeling (pt bonded two-way slab)

40
BEHAVIOR OF GROUT-BONDED VS. UNBONDED PT CONCRETE STRUCTURES University of Oklahoma Civil Engineering and Environmental Science May 3 rd 2011 Thomas Kang Ph.D., P.E. Assistant Professor

Upload: trinhnga

Post on 13-Feb-2017

237 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: TESTS & MODELING (PT Bonded Two-way Slab)

BEHAVIOR OF GROUT-BONDED VS.

UNBONDED PT CONCRETE STRUCTURES

University of Oklahoma

Civil Engineering and Environmental Science

May 3rd 2011

Thomas Kang Ph.D., P.E.

Assistant Professor

Page 2: TESTS & MODELING (PT Bonded Two-way Slab)

ACKNOWLEDGEMENTS

1. Substantial input from K.R. Chung & J.W. Park

( , Seoul, Korea)

2. Finite element analysis assistance of Y. Huang,

Ph.D. Student, University of Oklahoma

• Reference No. 1: PTI Journal (Next issue)

• Reference No. 2: Int. Journal of Theoretical & Applied

Multiscale Mechanics (Dec. 2010)

3. Funding support for student and faculty (U.S. DOT-RITA)

4. On-going industry collaboration: C. Hayek ( , USA)

Page 3: TESTS & MODELING (PT Bonded Two-way Slab)

BONDED PT SYSTEM (PT Transfer Girder)

Courtesy of C. Hayek

Page 4: TESTS & MODELING (PT Bonded Two-way Slab)

BONDED PT SYSTEM (PT Transfer Girder)

Courtesy of C. Hayek

Page 5: TESTS & MODELING (PT Bonded Two-way Slab)

BONDED PT SYSTEM (VSL Bonded Tendon System for Flat Plate)

Page 6: TESTS & MODELING (PT Bonded Two-way Slab)

BONDED PT SYSTEM (VSL Bonded Tendon System for Flat Plate)

Page 7: TESTS & MODELING (PT Bonded Two-way Slab)

BONDED PT SYSTEM (Freyssinet Bonded Tendon System for Flat Plate)

Page 8: TESTS & MODELING (PT Bonded Two-way Slab)

PT BLDG. IN DUBAI (Bonded PT Flat Plate)

Dubai, Arab Emirates

Residential & Office Building

24 Floors + 2 Basement Floors

Structural Design:

Dongyang (Korea)

Page 9: TESTS & MODELING (PT Bonded Two-way Slab)

Typical Module:

11.3 m x 9.6 m

(37 x 31.5 ft)

Drop Panel

Thickness:

350 mm (13.8 in.)

PT BLDG. IN DUBAI (Bonded PT Flat Plate)

Page 10: TESTS & MODELING (PT Bonded Two-way Slab)

Courtesy of K.R. Chung

PT BLDG. IN DUBAI (Bonded PT Flat Plate)

Page 11: TESTS & MODELING (PT Bonded Two-way Slab)

PT BLDG. IN SEATTLE (Unbonded PT Flat Plate)

Courtesy of J. Brink

Page 12: TESTS & MODELING (PT Bonded Two-way Slab)

PT BLDG. IN D.C. (Unbonded PT One-way Beam)

Courtesy of C. Hayek

Page 13: TESTS & MODELING (PT Bonded Two-way Slab)

RESEARCH NEEDS

Objectives

Review of prior experimental data

Developing FE models (both bonded and unbonded PT)

Comparison with the data and codes

PT slab-column connections

experienced punching damage

during Northridge EQ (1994).;

Four Seasons Bldg., Sherman

Oaks, CA – demolished (2005)

Page 14: TESTS & MODELING (PT Bonded Two-way Slab)

TESTING OF BONDED PT STRUCTURES

Mattock et al. (1971)

Seven simply supported PT

single-span beams and three

continuous two-span beams with

bonded or unbonded tendons

Cooke et al. (1981)

Twelve simply supported PT one-

way slabs with bonded or

unbonded tendons

Warnitchai et al. (2004)

Two PT bonded interior slab-

column connections with and

without drop panel

Simply supported PT one-way beam

(Mattock et al., 1971)

Page 15: TESTS & MODELING (PT Bonded Two-way Slab)

TESTS & MODELING (PT Bonded Beams)

Mattock et al. (1971)

One bonded PT beam and two unbonded PT beams; same prestressing

Page 16: TESTS & MODELING (PT Bonded Two-way Slab)

Cooke et al. (1971)

Three bonded and three unbonded PT one-way slabs; same other conditions

TESTS & MODELING (PT Bonded One-way Slabs)

Page 17: TESTS & MODELING (PT Bonded Two-way Slab)

Warnitchai et al. (2004)

A bonded PT interior two-way slab-column connection (unbonded not tested)

TESTS & MODELING (PT Bonded Two-way Slab)

Bonded PT slab-column

connection tested in Thailand

(Warnitchai et al., 2004)

Page 18: TESTS & MODELING (PT Bonded Two-way Slab)

Warnitchai et al. (2004)

A bonded PT interior two-way slab-column connection (unbonded not tested)

TESTS & MODELING (PT Bonded Two-way Slab)

Page 19: TESTS & MODELING (PT Bonded Two-way Slab)

TESTS & MODELING (PT Bonded Beams)

Mattock et al. (1971)

Page 20: TESTS & MODELING (PT Bonded Two-way Slab)

TESTS & MODELING (PT Bonded Beams)

Mattock et al. (1971)

Page 21: TESTS & MODELING (PT Bonded Two-way Slab)

TESTS & MODELING (PT Bonded Beams)

Mattock et al. (1971)

One bonded PT beam and two unbonded PT beams; same prestressing

Page 22: TESTS & MODELING (PT Bonded Two-way Slab)

Cooke et al. (1971)

TESTS & MODELING (PT Bonded One-way Slabs)

Page 23: TESTS & MODELING (PT Bonded Two-way Slab)

Cooke et al. (1971)

TESTS & MODELING (PT Bonded One-way Slabs)

Page 24: TESTS & MODELING (PT Bonded Two-way Slab)

Warnitchai et al. (2004)

TESTS & MODELING (PT Bonded Two-way Slab)

Page 25: TESTS & MODELING (PT Bonded Two-way Slab)

Warnitchai et al. (2004)

TESTS & MODELING (PT Bonded Two-way Slab)

Page 26: TESTS & MODELING (PT Bonded Two-way Slab)

Warnitchai et al. (2004)

TESTS & MODELING (PT Bonded Two-way Slab)

Page 27: TESTS & MODELING (PT Bonded Two-way Slab)

Warnitchai et al. (2004)

TESTS & MODELING (PT Bonded Two-way Slab)

Page 28: TESTS & MODELING (PT Bonded Two-way Slab)

Warnitchai et al. (2004)

TESTS & MODELING (PT Bonded Two-way Slab)

Analytical result

of tensile stress pattern

(under monotonic lateral loading) Observed crack pattern

(under reversed cyclic loading)

Page 29: TESTS & MODELING (PT Bonded Two-way Slab)

Warnitchai et al. (2004)

TESTS & MODELING (PT Bonded Two-way Slab)

Page 30: TESTS & MODELING (PT Bonded Two-way Slab)

Warnitchai et al. (2004)

TESTS & MODELING (PT Bonded Two-way Slab)

Strains in bonded tendon

(Exp. vs. FEA)

Shear stress distribution

at the critical section

(FEA)

Page 31: TESTS & MODELING (PT Bonded Two-way Slab)

Warnitchai et al. (2004)

TESTS & MODELING (PT Bonded Two-way Slab)

Strains in bonded tendon

(Exp. vs. FEA)

Shear stress distribution

at the critical section

(FEA)

Page 32: TESTS & MODELING (PT Bonded Two-way Slab)

BONDED VS. UNBONDED (Constructability Issues)

Tendon

Bonded

Unbonded

Slab

20

1

3

20

53.5

mm

Bonded rebar

Slab soffit

Duct

12.7 mm strands (dia.: 12.7mm or ½ in.)

16

1

6

20

44 m

m

Slab soffit

12.7mm strands

(dia.: 6mm, incl. cover)

c.g.s.

1~2 cm difference

For 200~250 mm thick

slab, unbonded is better

Reduced

effective depth

No change in

effective depth

Page 33: TESTS & MODELING (PT Bonded Two-way Slab)

Bonded Unbonded

New post-

tensioning

unnecessary

New post-

tensioning

necessary

If broken, tendon at other locations is okay. Once tendon is broken, no force exists.

BONDED VS. UNBONDED (Rehabilitation Issues)

Page 34: TESTS & MODELING (PT Bonded Two-way Slab)

Bonded Unbonded

No horizontal curve Horizontal curve

BONDED VS. UNBONDED (Constructability Issues)

Page 35: TESTS & MODELING (PT Bonded Two-way Slab)

Bonded Unbonded

Push strands into the duct Extruded tendons

BONDED VS. UNBONDED (Constructability Issues)

Page 36: TESTS & MODELING (PT Bonded Two-way Slab)

BONDED VS. UNBONDED (Constructability Issues)

Bonded Unbonded

Hard to fix, once grouted Adjustment on site is easy.

Page 37: TESTS & MODELING (PT Bonded Two-way Slab)

BONDED VS. UNBONDED (Constructability Issues)

Unbonded

250

Obstruction with column

longitudinal bars

Minimal obstruction by

column longitudinal bars

Bonded

Page 38: TESTS & MODELING (PT Bonded Two-way Slab)

BONDED VS. UNBONDED (Constructability Issues)

Bonded Type Unbonded Type Misc.

Cost regarding

tendons

Cost for Duct and Grouting,

Tendon Max Spacing Cost for anchorages

Unbonded is

better for thinner

members

Bonded

reinforcement

No req’t for minimum bonded

reinforcement (except for Mcr)

Minimum bonded

reinforcement

Cost/Area

Thickness

Bonded

Unbonded

Depends on the number of ducts

Not influenced by tendon layout and spacing

Page 39: TESTS & MODELING (PT Bonded Two-way Slab)

SUMMARY

1. For flat plates, unbonded PT systems dominate in the

U.S. (while there are some bonded PT projects in the

east coast)

2. For transfer girders and bridges, bonded PT systems are

more popular.

3. Structural performance is similar (while drift capacity of a

bonded PT slab-column connection may be lower than

that of unbonded PT connection)

4. Constructability issues – depends on the market and

project.

Page 40: TESTS & MODELING (PT Bonded Two-way Slab)

Thank You!

Any Questions? Kang’s research

on steel FRC

beams in shear

at U of Oklahoma

Kang’s research

on RC T-joints

under cyclic loads

at U of Oklahoma