EIncorrect Crimp Quality Good Crimp Quality Test
Training
TE APPLICATION TOOLING: LITEALUM
CRIMP QUALITY GUIDELINES
Correct Incorrect Test Training
Crimp heights and tolerances
Insulation fixation
according to application specification 114-94204
For crimp height tolerances for any given contact, please refer to the relevant application specification.
Bending test according to application specification 114-94204
Digital crimp height micrometer (0.001 mm increments) according to DIN ISO 9001 Part number: 547203-1
CB2m: Insulation crimp widthCB1m: Conductor crimp width
CH2: Insulation crimp heightCH1: Conductor crimp height
Examples
Contact Order-No P/N
Wire Range
Conductor CH1
Insulation CH2
JPT LITEALUM 2-2177894-1 2.5 mm2 ±0.04 mm ±0.1 mm
SPT LITEALUM 2-1862001-1 4.0 mm2 ±0.04 mm ±0.1 mm
AMP MCP 6.3/4.8K LITEALUM
2-2177840-1 6.0 mm2 ±0.04 mm ±0.1 mm
Training schedule information in English or German:
Telephone: +49 6151 607 1518 E-mail: [email protected]
or contact your local TE Connectivity representative for information in your language.
CR
IMP
HEI
GH
T M
EASU
REM
ENT
AN
D T
OLE
RA
NC
ESIN
SULA
TIO
N F
IXA
TIO
NTR
AIN
ING
In the event of large imper-fections, as shown here, the position of the sectioning layer should be checked.
Terminal asymmetrically positioned over the anvil
Terminal asymmetrically positioned over the anvil
Cracking in the bottom of the front cover crimp
Axial misalignment of crimp flanks
Cover crimp flanks are visible outside crimp
Asymmetrical imprintConductors are visible outside crimp
Locking lance
Insulation barrel with grips
Filler deposit
Carrier strip
Front cover wings
Transition zone
Conductor crimp barrel with serrations, covered with additive
Terminal body
Uniform shape along length, entire seam closed, funnel- shaped expansion between wire and insulation crimps.
Seam is closed and no insulation is seen in the seam.
A: Front cover crimp B: Wire crimp C: Insulation crimp D: Longitudinal section
110°
110°
Wire tip position setup is important to proper termination. Refer to appropriate application specification for instructions. After setup, verify with longitudinal cross section.
CH
1
CB1m
CH
2
CB2m
Stripping length
Front strands flush with reference line
3x
1
1
2
2
3
3
4
4
5
5
6
6
7
7
AMP MCP, LITEALUM, TE Connectivity and TE connectivity (logo) are trademarks.© 2015 TE Connectivity. All rights reserved.
The above images of crimp failures are only shown as examples and are by no means exhaustive of all possible failures. In every case, relevant product and application specification take precedence.
Where specified by TE Connectivity, Automotive users within EMEA have to meet TE Application Specification 114-94204 when processing open crimp barrels.
www.tooling.te.com1-1654337-5 Revised 04-2015
Housing
Filler deposit
Crimp barrel
Front cover crimp may have different crimp height than wire crimp. Refer to applica-tion specification.
Anvil side footprint is symmetrical. Clear anvil impression on both sides of insulation crimp.