supra bridge installation guide - lumishore€¦ · www .lumishore.com lumishore uk unit 3,...
TRANSCRIPT
www.Lumishore.comLumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
45-0156 - Rev 1
SUPRA BRIDGEInstallation Guide
Please read the following pages before attempting installation to ensure completeunderstanding of the LUMISHORE Lumi-Link SUPRA Bridge
PARTS INCLUDED
1 x FIELD INSTALL RJ45 IP67 COVER KIT(39-0235)
www.Lumishore.comLumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
MFD COMPATABILITY
- Garmin (OneHelm Enabled)- Raymarine - Axiom (Lighthouse Partner App)- Navico - Simrad (NSO EVO3 and EVO2, NSS EVO3 and Go**), B&G (Zeus3 Glass Helm, Zeus3 and Vulcan)- Furuno (Models TBC)
Lumi-Link SUPRA Bridge Installation Instructions
Before you start…
• Alwaysensurethatthevessel’spowersourceandbatteryaredisconnectedorisolatedpriorto installation.
• Aqualifiedprofessionalshouldcarryoutboththeelectricalandmechanicalinstallation.
• TheSUPRAlightingsystemshouldbefullyinstalledbeforeconnectingthe Lumi-LinkSUPRABridge.
• TheLumi-LinkSUPRABridgemustbemountedinadrylocationandonaflat(notcurved) surfaceawayfromanysourcesofheatorvibration
• TheLumi-LinkSUPRABridgeworkswiththeLumi-LinkDisplayandorcompatible Multi-functionDisplays(MFD).-checkthecompatibilityofyourMFDpriortoinstallingthe Lumi-LinkSUPRABridge.TheMFDmayrequireasoftwareupdate.
• TheLumi-LinkSUPRABridgehasanaccessibleSDcardslotforfuturesoftwareupgrades. Whenmounting,futureaccesstothisSDcardslotshouldbetakenintoconsideration.
Connection Options…
TheLumi-LinkSUPRABridgeisacrossplatformdevice.Viaethernet,itcanconnecttoasingleormul-tipleMFDnetwork,connecttoaLumishoreLumi-linkdisplayorbecontrolledbyasmartPhone/tablet(viaWi-Fi).
CompatibleMFD’sincludethefollowing…
TheLumi-linkDisplaycanbeusediftherearenoMFD’sonthevesselorifadditionalaccesspointsarerequiredaroundthevessel.ForfulldetailsoftheLumi-linkDisplayseeLumi-LinkDisplayinstallationinstructions.
Viaanon-boardWi-Finetwork(eitherthroughtheMFDWi-FiorthroughtheLumi-LinkDisplayon-boardWi-Fi)theLumi-linkappcanbecontrolledfromasmartdevice.FullinstructionsforthisareincludedintheLumi-LinkSUPRABridgeusermanual.
www.Lumishore.comLumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
Note: use a MFD manufacturer specific Network expansion port - consult with your MFD installation guide or contact a dealer for further advice
Single MFD Connection Lumi-Link Display Connection
Multiple MFD Connection
www.Lumishore.comLumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
PLEASE REFER TO RJ45 IP67 ASSEMBLY INSTRUCTIONS SUPPLIED WITH RJ45
COVER KIT (39-0235)
Connecting the Lumi-Link SUPRA Bridge to the Lumi-Link Display or MFD
FordirectconnectiontotheLumishoreLumi-LinkDisplayanystandardethernetnetworkcablecanbeused.ConnectiontothevariousbrandsofMFD’sarebrandspecific.ThefollowingdiagramsshowthecomponentsrequiredtoconnecttheLumi-LinkSUPRABridgetoeachbrand.
ThelengthofnetworkcabledependsonwheretheLumi-linkSUPRABridgehasbeeninstalledrelativetotheDisplayorMFD.EachMFDmanufactureroffersdifferentlengthsofnetworkcable,checkyourinstallationlengthbeforeordering.
LumishoresuppliesaFieldinstallRJ45IP67covertomakeyourconnectionstotheLumi-LinkSUPRABridgewaterproof.Thecovershouldbeusedonallinstallations.Note:TheinternalsupportmayormaynotberequireddependingonthetypeofEthernetconnectormolding.
Field install IP67 RJ45 Cover Assembly
Lumi-Link Display - Use standard Ethernet Cat5e cable
www.Lumishore.comLumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
Raymarine MFD Install - Use Raynet to RJ45 Cable - Raymarine PN: A80151
Garmin MFD Install - Use Garmin Conversion Cable PN: 60-0372 and Garmin Network Cable.
(Note: The Garmin Conversion cable MUST be installed - only use Garmin network cables)
www.Lumishore.comLumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
Simrad & B&G MFD Install - Use Navico Conversion Cable PN: 60-0373
Furuno MFD Install - Use Standard Ethernet Cat5e cable
www.Lumishore.comLumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
Lumi-Link SUPRA Bridge Connections
TheSUPRABridgeusesproprietarydatamessagestocommunicatebetweenthelightsandcontroller.TheLumi-LinkSUPRABridgecanonlybeusedtocontrolLumishoreSUPRAproducts.
TheLumi-LinkSUPRABridgeispluggedintotheDataINportontheSUPRAHub(seeexamplediagramsonthefollowingpages).
• TheLumi-LinkSUPRABridgeisfor12/24voltDCoperation(10-31voltinput).Underno circumstancesshouldtheBridgebeconnecteddirectlytoMainsACvoltage.
• AlwaysuseasuitablefuseorcircuitbreakertoprotecttheLumi-LinkSUPRABridge andeachelementofthesystem.
3PinM12Lumi-LinkDataoutconnector:
Plugthe3-PinM12ConnectordirectlyintotheDataINportoftheSUPRAHub.Thecablescanbeex-tendedusingLumi-Linkextensioncables.
Pre-moldedLumi-linkDMXcablesareavailablein1meter,5meterand15meterlengthsasrequired.Multiplecablescanbecombinedifafurtherdistanceisrequired.
LENGTH PART NUMBER1m 60-04035m
15m60-040460-0405
www.Lumishore.comLumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
SUPRA Underwater Light installation Example diagrams:
www.Lumishore.comLumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
Lumi-Link SUPRA Bridge - Status LED’s
IfpowertotheLumi-LinkSUPRABridgeislosttemporarilythenthesystemmaynotfullyfunctionuntilyouexittotheHomescreenontheMFD,andthenre-selecttheLumi-LinkScreen.
IftherearemultipleMFDsinuse,andoneoftheMFDsisusedtoaccessaset-upmode(e.g.LightSet-Up),thentheotherMFDswillbelockedoutandwilldisplayamessage.Ifthismessageisseen,exittothehomescreen.Oncetheset-upiscompletedthesystemcanbeusedasnormal.
Warranty
LUMISHORELtdwarrantsthe Lumi-Link SUPRA Bridgetobefreefromdefectsinworkmanshipandmaterialsforaperiodoftwoyears,startingfromthedateoforiginalpurchase.Misuse,abuse,improp-erinstallation,neglect,impropershipping,damagecausedbydisasterssuchasfire,flood,andlight-ning,installationbyunqualifiedpersonnel,unauthorizedrepairormodificationwillvoidthiswarranty.Fortheavoidanceofconfusionanddoubt,non-compliancewithallinstallation,maintenanceandoperatinginstructionsinthisdocumentconstitutenon-conformancewithwarrantyterms.
www.Lumishore.comLumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
Lumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
LED Status Power LED
Solid ON Healthy
OFF
Flashing
No Power
N/A
Data LED
Healthy - Data Being Received
No Power
Healthy - Ready For Data