submittal register

33
SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 1 OF 33 PAGES Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI 01 11 00 SD-01 Preconstruction Submittals 1.5.2.2 G RO Progress Schedule 1.11 G RO Electronic Security Memorandum 1.10.1 G RO Utility Outage Requests 1.10.1 G RO Utility Connection Requests 01 33 00 SD-01 Preconstruction Submittals 1.8 G RO Submittal Register 01 35 27.00 SD-01 Preconstruction Submittals 1.5.2 G RO Construction Safety Plan 1.5.2 G RO Construction Safety Plan 1.6.1 G RO Work Plan 1.5.1 G RO Quality Control Plan 1.5.1 G RO Quality Control Plan 1.6 G RO Infection Control Plan 3.5 G RO Interim Life Safety Measures (ILSM) SD-03 Product Data 2.1 G RO Plastic Sheet Barrier 3.5 G RO Plastic Sheet Barrier 3.6 G RO Plastic Sheet Barrier 3.6 G RO HEPA Filters 2.1 G RO Sticky Walk-off Mats 3.5 G RO Sticky Walk-off Mats 3.6 G RO Sticky Walk-off Mats SD-06 Test Reports 3.2 G RO Negative Pressure Test Reports SUBMITTAL REGISTER CONTRACT NO. TITLE AND LOCATION CONTRACTOR CONTRACTOR: SCHEDULE DATES CONTRACTOR ACTION APPROVING AUTHORITY A C T I V I T Y N O T R A N S M I T T A L N O S P E C S E C T DESCRIPTION ITEM SUBMITTED P A R A G R A P H # C L A S S I F I C A T I O N G O V T O R A / E R E V W R SUBMIT APPROVAL NEEDED BY MATERIAL NEEDED BY A C T I O N C O D E DATE OF ACTION DATE FWD TO APPR AUTH/ DATE RCD FROM CONTR DATE FWD TO OTHER REVIEWER DATE RCD FROM OTH REVIEWER A C T I O N C O D E DATE OF ACTION MAILED TO CONTR/ DATE RCD FRM APPR AUTH REMARKS (a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r) VA241-12-R-0716 Project Number 650-07-115

Upload: others

Post on 29-May-2022

13 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 1 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

01 11 00 SD-01 Preconstruction Submittals1.5.2.2 G ROProgress Schedule1.11 G ROElectronic Security Memorandum1.10.1 G ROUtility Outage Requests1.10.1 G ROUtility Connection Requests

01 33 00 SD-01 Preconstruction Submittals1.8 G ROSubmittal Register

01 35 27.00 SD-01 Preconstruction Submittals1.5.2 G ROConstruction Safety Plan1.5.2 G ROConstruction Safety Plan1.6.1 G ROWork Plan1.5.1 G ROQuality Control Plan1.5.1 G ROQuality Control Plan1.6 G ROInfection Control Plan3.5 G ROInterim Life Safety Measures

(ILSM)SD-03 Product Data

2.1 G ROPlastic Sheet Barrier3.5 G ROPlastic Sheet Barrier3.6 G ROPlastic Sheet Barrier3.6 G ROHEPA Filters2.1 G ROSticky Walk-off Mats3.5 G ROSticky Walk-off Mats3.6 G ROSticky Walk-off Mats

SD-06 Test Reports3.2 G RONegative Pressure Test Reports

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 2: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 2 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

01 35 27.00 3.5 G RONegative Pressure Test Reports3.2 G ROInfection Control Compliance

Daily Checklist3.10 G ROInfection Control Compliance

Daily Checklist3.10 G ROInfection Control Compliance

Daily Checklist01 35 29 SD-01 Preconstruction Submittals

1.7 G AAccident Prevention Plan (APP)1.8 G AActivity Hazard Analysis (AHA)1.7.1 G ACrane Critical Lift Plan1.5.1.2 G ACrane Operators

SD-06 Test Reports1.12Reports1.12.1Accident Reports1.12.3Monthly Work-hour Reports1.12.4Crane Reports

Regulatory Citations andViolations

SD-07 Certificates1.9Confined Space Entry Permit1.9Hot work permit1.12.5Certificate of Compliance

01 57 20 SD-01 Preconstruction Submittals1.7 G ROEnvironmental Protection Plan

01 78 00 SD-11 Closeout Submittals

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 3: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 3 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

01 78 00 1.2.1 G DOAs-Built Drawings1.3Final Clean-Up

02 41 00 SD-01 Preconstruction Submittals1.6.1 G ROExisting Conditions

SD-07 Certificates1.9 G AEDemolition Plan1.9 G AEDeconstruction Plan1.4.1 G RONotifications

SD-11 Closeout Submittals1.4.2 G ROReceipts

02 82 16.00 20 SD-03 Product Data3.1.4 G AELocal exhaust equipment3.1.5 G AEVacuums3.1.1.1 G AERespirators3.1.4 G AEPressure differential automatic

recording instrument1.2.2 G AEAmended water3.1.7 GGlovebags1.3.8 G AEMaterial Safety Data Sheets

(MSDS) for all materials2.1 G AEEncapsulants

SD-06 Test Reports1.5.5 G AEAir sampling results1.5.6 G AEPressure differential recordings

for local exhaust system3.3.3.2 G AEAsbestos disposal quantity report

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 4: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 4 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

02 82 16.00 20 G AEEncapsulation test patches3.2.6.3 G AEClearance sampling

SD-07 Certificates1.3.9 G AEAsbestos hazard abatement plan1.3.10 G AETesting laboratory1.5.1 G AEPrivate qualified person

documentation1.5.4 G AEContractor's license1.5.2 G AECompetent person1.5.3 G AEWorker's license1.3.11 G AELandfill approval1.3.3 G AEEmployee training1.3.12 G AEMedical certification1.3.11 G AEWaste shipment records1.3.6 G AERespiratory Protection Program1.3.11 G AEDelivery tickets3.1.5 G AEVacuums3.1.2.3 G AEWater filtration equipment3.1.5 G AEVentilation systems3.1 G AEEquipment used to contain

airborne asbestos fibers2.1 G AEEncapsulants1.3.4 G AENotifications1.3.4 G AENotifications

SD-11 Closeout Submittals1.3.4 G AENotifications

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 5: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 5 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

02 82 16.00 20 1.3.4 G AENotifications1.6.1 G AERental equipment1.3.6.1 G AERespirator program records1.3.4 G AEPermits

02 83 13.00 20 SD-01 Preconstruction Submittals1.5.2.3 G AEOccupational and Environmental

Assessment Data Report1.5.2.2 G AELead Compliance Plan1.5.1.1 G AECompetent Person1.5.1.2 G AETraining Certification1.5.2.8 G AELead Waste Management Plan3.5.2.1 G AEWritten Evidence1.5.2.4 G AEMedical Examinations

SD-06 Test Reports1.5.2.3 G AESampling Results1.5.2.3 G AEOccupational and Environmental

Assessment Data ReportSD-07 Certificates

1.5.1.3 G AETesting LaboratorySD-11 Closeout Submittals

3.5.2.1 G AEHazardous Waste Manifest3.5.2.1 G AETurn-in Documents or Weight

Tickets04 20 00 SD-02 Shop Drawings

G AEDetail DrawingsSD-03 Product Data

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 6: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 6 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

04 20 00 1.5.2 G AECold Weather InstallationG AEFlashing

SD-04 Samples2.2 G AEClay or Shale Brick

G AEAnchors, Ties, and BarPositioners

SD-05 Design Data2.3.3 G AEPre-mixed Mortar

G AEUnit Strength MethodSD-08 Manufacturer’s Instructions

2.3 G AEMasonry Cement05 40 00 SD-02 Shop Drawings

1.4.1 G AEFraming ComponentsSD-03 Product Data

2.1 G AEStuds, Joists05 50 13 SD-02 Shop Drawings

G AEFabrication DrawingsG AEInstallation Drawings

SD-03 Product DataG AEBoltsG AENuts and WashersG AEConnecting HardwareG AEExpansion or Other Anchors

06 20 00 SD-02 Shop Drawings1.3 G AEDetail Drawings

07 54 19 SD-02 Shop Drawings

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 7: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 7 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

07 54 19 1.3.2 G AERoofing SystemSD-03 Product Data

3.2 G AEInstallation3.5 G AEProtection of Finished Roofing3.6 G AEInspection

SD-07 Certificates1.3.1 G AEMaterials1.3.5 G AEQualifications

07 60 00 SD-02 Shop Drawings3.10 G AEBase flashing3.10 G AECounterflashing3.11 G AEFlashing at roof penetrations

SD-11 Closeout Submittals3.15 G AEQuality Control Plan

07 84 00 SD-02 Shop Drawings2.1 G AEFirestopping Materials

SD-07 Certificates2.1 G ROFirestopping Materials1.5 G ROInstaller Qualifications3.3 G ROInspection

07 92 00 SD-03 Product Data2.1 G AESealants2.1.5.1 G AEPrimers

SD-07 Certificates3.3.2 G ROSealant

08 14 00 SD-02 Shop Drawings

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 8: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 8 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

08 14 00 2.1 G AEDoorsSD-03 Product Data

2.1 G AEDoors2.2 G AEAccessories1.4 G AEWarranty

G AESound transmission class ratingG AEFire resistance rating

SD-06 Test Reports2.4 G ROSplit resistance2.4 G ROCycle-slam2.4 G ROHinge loading resistance

08 71 00 SD-02 Shop Drawings1.3 G AEHardware schedule2.2.5 G AEKeying system

SD-03 Product Data2.2 G AEHardware items

SD-08 Manufacturer’s Instructions3.1 G ROInstallation

SD-10 Operation and MaintenanceData

1.3 G ROHardware ScheduleSD-11 Closeout Submittals

1.4 G ROKey Bitting08 81 00 SD-02 Shop Drawings

3.2.1 G AEInstallationSD-03 Product Data

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 9: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 9 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

08 81 00 1.6.1 G AEInsulating Glass2.2 G AESetting and Sealing Materials

G AEPlastic Glazing2.2.2 G AEGlazing Compound1.3 G AEGlazing Accessories

SD-07 Certificates1.6.1 G ROInsulating Glass

G AEPlastic Glazing09 29 00 SD-03 Product Data

2.1 G AECementitious backing units1.3.2 G AEGypsum Board2.1.4 G AEAdhesives2.1.5 G AEAccessories

SD-07 Certificates2.1 G ROAsbestos Free Materials

SD-08 Manufacturer’s Instructions2.1 G ROMaterial Safety Data Sheets

SD-10 Operation and MaintenanceData

2.1 G ROManufacturer maintenanceinstructions

G ROWaste Management09 51 00 SD-02 Shop Drawings

1.3 G AEApproved Detail DrawingsSD-03 Product Data

3.1.3 G AEAcoustical Ceiling Systems

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 10: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 10 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

09 51 00 SD-04 Samples2.1 G ROAcoustical Units

SD-06 Test Reports1.3.1 G ROCeiling Attenuation Class and

TestSD-07 Certificates

2.1 G ROAcoustical Units09 65 00 SD-02 Shop Drawings

2.7 G AEResilient Flooring andAccessories

SD-03 Product Data2.7 G AEResilient Flooring and

Accessories2.3 G AEAdhesives2.1Vinyl Composition Tile

SD-04 Samples2.7 G ROResilient Flooring and

AccessoriesSD-06 Test Reports

3.3 G ROMoisture, Alkalinity and BondTests

SD-08 Manufacturer’s Instructions3.2 G ROSurface Preparation3.1 G ROInstallation

SD-10 Operation and MaintenanceData

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 11: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 11 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

09 65 00 2.7 G ROResilient Flooring andAccessories

09 90 00.00 40 SD-03 Product Data2.1 G AEAcrylic Latex

SD-04 Samples2.1 G ROManufacturer's Standard Color

ChartsSD-07 Certificates

3.1 G ROSafety PlanSD-08 Manufacturer’s Instructions

G ROManufacturer's instructions13 48 00.00 10 SD-02 Shop Drawings

3.1 G AECoupling and Bracing3.3 G AEFlexible Couplings or Joints1.3 G AEEquipment Requirements1.2.4 G AEContractor Designed Bracing

SD-03 Product Data3.1 G AECoupling and Bracing1.3 G AEEquipment Requirements1.2.4 G AEContractor Designed Bracing

SD-07 Certificates2.2Flexible Ball Joints

13 48 00 SD-02 Shop Drawings3.1 G AEBracing3.4 G AEResilient Vibration Isolation

Devices

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 12: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 12 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

13 48 00 1.3 G AEEquipment RequirementsSD-03 Product Data

3.1 G AEBracing1.3 G AEEquipment Requirements

SD-06 Test Reports3.3 G AEAnchor Bolts

21 13 13.00 10 SD-02 Shop Drawings1.4.3 G AEShop Drawings3.7 G AEAs-Built Drawings

SD-03 Product Data1.4.1 G AEFire Protection Related

Submittals2.2 G AEMaterials and Equipment1.6Spare Parts3.6Preliminary Tests3.7Final Acceptance Test1.4.1 G ROFire Protection Specialist1.4.2Sprinkler System Installer

SD-05 Design Data1.4.3 G AESway Bracing

SD-06 Test Reports3.7 G ROPreliminary Test Report3.7 G ROFinal Acceptance Test Report

SD-07 Certificates3.3 G ROInspection by Fire Protection

Specialist

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 13: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 13 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

21 13 13.00 10 SD-10 Operation and MaintenanceData

3.8 G ROOperating and MaintenanceInstructions

22 00 00 SD-02 Shop Drawings3.4.1 G AEPlumbing System

SD-03 Product Data2.3 G AEValves2.5 G AEDrains

SD-06 Test Reports3.4 G AETests, Flushing and Disinfection

SD-07 Certificates1.3 G AEMaterials and Equipment

SD-10 Operation and MaintenanceData

3.4.1 G ROPlumbing System23 00 00 SD-02 Shop Drawings

1.4.5 G AEDetail DrawingsSD-03 Product Data

2.1 G AEStandard Products2.9.1.1 G AEMetallic Flexible Duct2.9.1.2 G AEInsulated Nonmetallic Flexible

Duct Runouts2.9.1.2 G AEDuct Connectors2.9.2.1 G AEDuct Access Doors2.9.2.2 G AEFire Dampers

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 14: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 14 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

23 00 00 2.9.2.3 G AEManual Balancing Dampers2.9.2.4 G AEAutomatic Smoke-Fire Dampers2.9.5.1 G AEDiffusers2.9.5.2 G AERegisters and Grilles2.11 G AEAir Handling Units2.12.1 G AERoom Fan-Coil Units

G AETest Procedures1.2.1 G AEDiagrams3.14 G AEOperation and Maintenance

TrainingSD-06 Test Reports

3.12 G AEPerformance Tests3.14 G AEPerformance Tests3.10 G AEDamper Acceptance Test

SD-08 Manufacturer’s Instructions3.2 G AEManufacturer's Installation

Instructions3.14 G AEOperation and Maintenance

TrainingSD-10 Operation and MaintenanceData

3.14 G ROOperation and MaintenanceManuals

2.11 G ROAir Handling Units2.12.1 G RORoom Fan-Coil Units

23 05 15 SD-01 Preconstruction Submittals

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 15: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 15 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

23 05 15 1.2 G AEMaterial, Equipment, and FixtureLists

SD-02 Shop Drawings1.2 G AERecord Drawings1.2 G AEConnection Diagrams1.2 G AECoordination Drawings1.2 G AEFabrication Drawings3.1 G AEInstallation Drawings

SD-03 Product Data2.1 G AEPipe and Fittings2.2 G AEPiping Specialties2.3 G AEValves2.4 G AEMiscellaneous Materials2.5 G AESupporting Elements1.2 G AEEquipment Foundation Data

SD-04 Samples1.2 G ROManufacturer's Standard Color

ChartsSD-05 Design Data

2.1 G ROPipe and Fittings2.2 G ROPiping Specialties2.3 G ROValves

SD-06 Test Reports3.1 G ROHydrostatic Tests3.1 G ROAir Tests3.1 G ROValve-Operating Tests

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 16: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 16 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

23 05 15 3.1 G RODrainage Tests3.1 G ROPneumatic Tests3.1 G RONon-Destructive Electric Tests3.1 G ROSystem Operation Tests

SD-07 Certificates1.2 G ROListing of Product Installations1.2 G RORecords of Existing Conditions3.1 G ROSurface Resistance3.1 G ROShear and Tensile Strengths3.1 G ROTemperature Ratings3.1 G ROBending Tests3.1 G ROFlattening Tests3.1 G ROTransverse Guided Weld Bend

TestsSD-10 Operation and MaintenanceData

3.10 G ROOperation and MaintenanceManuals

23 05 48 SD-02 Shop Drawings1.2 G AEInstallation Drawings1.2 G AEOutline Drawings

SD-03 Product Data1.2 G AEEquipment and Performance

Data2.1.2 G AEMountings2.1.3 G AEBases

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 17: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 17 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

23 05 48 2.3 G AEIsolators2.3.1 G AEFloor-Mounted Piping2.3.2 G AEVertical Piping

SD-06 Test Reports2.1 G ROType of Isolator2.1 G ROType of Base2.1 G ROAllowable Deflection2.1 G ROMeasured Deflection

23 05 93 SD-01 Preconstruction Submittals1.3 G AERecords of Existing Conditions1.3.3 G AERecords of Existing Conditions1.2 G ROTAB Firm1.5.3.1 G ROTAB Firm1.2 G ROTAB team assistants1.2 G ROTAB team engineer1.2 G ROTAB team field leader1.5.3.2 G ROTAB Specialist

SD-02 Shop Drawings1.3.3 G ROTAB Schematic Drawings and

Report FormsSD-03 Product Data

1.3 G ROEquipment and PerformanceData

1.5.3.4 G ROTAB Related HVAC Submittals1.5.2 G ROTAB Procedures1.5.2 G ROCalibration

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 18: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 18 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

23 05 93 1.3.3 G ROSystems Readiness Check1.5.4 G ROTAB Execution1.5.4.3 G ROTAB Verification

SD-06 Test ReportsG ROTAB Work Execution ScheduleG AETAB Procedures Summary

1.7.2 G AEPre-final TAB Report1.7.2Final TAB Report1.5.5.1 G AETAB report for Season 1

SD-07 Certificates1.2 G ROTAB Firm1.5.3.1 G ROTAB Firm1.5.1 G ROIndependent TAB Agency and

Personnel Qualifications1.3.3 G RODesign review report1.7.2.1 G RODesign review report

23 07 00 SD-02 Shop Drawings2.3 G AEPipe Insulation Systems3.2 G AEPipe Insulation Systems3.3 G AEDuct Insulation Systems3.4 G AEEquipment Insulation Systems

SD-03 Product Data2.3 G AEPipe Insulation Systems3.2 G AEPipe Insulation Systems3.3 G AEDuct Insulation Systems3.4 G AEEquipment Insulation Systems

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 19: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 19 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

23 07 00 SD-04 Samples2.2.1.3 G ROThermal Insulation

SD-08 Manufacturer’s Instructions2.3 G ROPipe Insulation Systems3.2 G ROPipe Insulation Systems3.3 G RODuct Insulation Systems3.4 G ROEquipment Insulation Systems

23 08 00.00 10 SD-02 Shop Drawings1.5.2.2 G AECommissioning Plan

SD-03 Product Data3.2.1 G AEPre-Functional Performance Test

Checklists3.2.2 G AEFunctional Performance Tests

SD-06 Test Reports3.3 G ROCommissioning Report

SD-07 Certificates1.5.1 G ROCommissioning Firm1.5.2 G ROCommissioning Specialist

23 09 23.13 20 SD-02 Shop Drawings1.4.1.1 G AEControl system drawings title

sheet1.4.1.2 G AEList of I/O Points1.4.1.3 G AEControl System Components List1.4.1.4 G AEControl system schematics1.4.1.5 G AEHVAC Equipment Electrical

Ladder diagrams

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 20: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 20 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

23 09 23.13 20 1.4.1.6 G AEComponent wiring diagrams1.4.1.7 G AETerminal strip diagrams1.4.1.8 G AEBACnet communication

architecture schematicSD-03 Product Data

2.1.1 G AEDirect Digital Controllers2.1.1.12 G AEBACnet Gateways3.4.8 G AEBACnet Protocol Analyzer2.2 G AESensors and Input Hardware2.3 G AEOutput Hardware2.4.2 G AESurge and transient protection2.6 G AEIndicators2.7 G AEVariable frequency (motor) drives2.1.2DDC Software

SD-05 Design Data3.4.2 G AEPerformance Verification Testing

Plan3.4.4 G AEPre-Performance Verification

Testing ChecklistSD-06 Test Reports

3.4.11 G ROPerformance Verification TestingReport

SD-07 Certificates1.6.6 G ROContractor's Qualifications

SD-09 Manufacturer’s FieldReports

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 21: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 21 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

23 09 23.13 20 3.4.1 G ROPre-PVT ChecklistSD-10 Operation and MaintenanceData

1.4 G ROBACnet Direct Digital ControlSystems

3.3 G ROControls System OperatorsManuals

2.7.2 G ROVFD Service ManualsSD-11 Closeout Submittals

3.5.1 G ROTraining documentation23 21 13.00 20 SD-02 Shop Drawings

1.3.1 G AEHot water heating systemSD-03 Product Data

2.3.1 G AEPumps2.3.2 G AEExpansion tanks2.3.4 G AEBackflow preventers2.3.3 G AEExternal air separation tanks2.1.1 G AEHot water heating pipe

SD-06 Test Reports3.3.1Hydrostatic test of piping system3.3.2Auxiliary equipment and

accessory testsSD-07 Certificates

1.5.4 G ROBackflow preventer certification1.5.2.1 G ROReport of prior installations1.5.2.2 G AEWelding procedures

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 22: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 22 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

23 21 13.00 20 1.5.2.3 G ROWelder's qualifications23 31 13 SD-01 Preconstruction Submittals

1.5 G AEMaterial, Equipment, and FixtureLists

1.5 G AERecords of Existing ConditionsSD-02 Shop Drawings

1.6 G AERecord Drawings1.3 G AEConnection Diagrams1.6 G AEConnection Diagrams

SD-03 Product Data1.2 G AEEquipment and Performance

Data2.1.1 G AEGalvanized Steel Ductwork

Materials2.2.1 G AERound Sheet Metal Duct Fittings2.2.4 G AETurning Vanes2.2.9 G AEFlexible Duct Materials2.2.11 G AEPower Operated Dampers2.2.6 G AEFlexible Connectors2.2.12 G AEFire Dampers and Wall Collars2.2.10 G AEManual Volume Dampers

SD-06 Test Reports1.2 G RODesign Analysis and Calculations1.3 G RODesign Analysis and Calculations3.4.2 G RODuctwork Leakage Tests3.4.1 G ROOperational Tests

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 23: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 23 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

23 31 13 SD-07 Certificates3.2 G ROListing of Product Installations2.1.1 G ROGalvanized Steel Ductwork

Materials2.2.1 G RORound Sheet Metal Duct Fittings2.2.4 G ROTurning Vanes2.2.5 G RODampers

SD-10 Operation and MaintenanceData

2.2.11 G ROPower Operated Dampers2.2.12 G ROFire Dampers and Wall Collars

23 37 13 SD-01 Preconstruction Submittals2.1 G AEMaterial, Equipment, and Fixture

Lists2.1 G AERecords of Existing Conditions

SD-02 Shop Drawings3.1 G AEInstallation Drawings

SD-03 Product Data1.3 G ROEquipment and Performance

DataSD-10 Operation and MaintenanceData

2.2.1 G ROType DP Supply Diffuser2.2.2 G ROType GR Return Grilles2.2.3 G ROType RR Return Register

23 64 10 SD-03 Product Data

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 24: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 24 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

23 64 10 3.1 G AEWater Chiller3.1 G AEWater Chiller3.4.1 G AEWater Chiller3.4.1 G AEWater Chiller3.4.2 G AEWater Chiller3.4.2 G AEWater Chiller3.6 G ROPosted Instructions1.5.1 G AEVerification of Dimensions1.7 G AEManufacturer's Multi-Year

Compressor Warranty2.8 G ROFactory Tests3.5 G ROSystem Performance Tests3.6 G RODemonstrations

SD-06 Test Reports3.4 G ROField Acceptance Testing3.1 G ROWater Chiller3.4.1 G ROWater Chiller3.4.2 G ROWater Chiller2.8 G ROFactory Tests3.5 G ROSystem Performance Tests

SD-07 Certificates3.1.2 G RORefrigeration System

SD-08 Manufacturer’s Instructions3.1 G ROWater Chiller3.4.1 G ROWater Chiller3.4.2 G ROWater Chiller

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 25: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 25 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

23 64 10 SD-10 Operation and MaintenanceData

3.6 G ROOperation and MaintenanceManuals

23 64 26 SD-03 Product Data2.2.2.4 G AEGrooved Mechanical

Connections For Steel2.10 G AECalibrated Balancing Valves2.11 G AEAutomatic Flow Control Valves2.12 G AEPump Discharge Valve2.13 G AEWater Temperature Mixing Valve2.14 G AEWater Temperature Regulating

Valves2.15 G AEWater Pressure Reducing Valve2.16 G AEPressure Relief Valve2.20.9 G AEExpansion Joints2.21 G AEPumps2.20.3 G AECombination Strainer and Pump

Suction Diffuser2.22 G AEExpansion Tanks2.23 G AEAir Separator Tanks2.23 G AEWater Treatment Systems

SD-06 Test Reports3.1.1.3 G ROPiping welds NDE report3.4.2 G ROPressure tests reports

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 26: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 26 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

23 64 26 3.6 G ROOne-Year Inspection Report ForCooling Water

SD-07 Certificates3.1.1.1 G ROEmployer's Record Documents

(For Welding)3.1.1.2 G ROWelding Procedures and

Qualifications1.7.2 G ROFittings2.2.2.1 G ROUnions2.2.2.2 G ROFlanges2.2.2.2 G ROGaskets

SD-08 Manufacturer’s Instructions3.5 G ROLesson plan for the Instruction

CourseSD-10 Operation and MaintenanceData

2.23 G ROWater Treatment Systems2.10 G ROCalibrated Balancing Valves2.11 G ROAutomatic Flow Control Valves2.12 G ROPump Discharge Valve2.13 G ROWater Temperature Mixing Valve2.14 G ROWater Temperature Regulating

Valves2.15 G ROWater Pressure Reducing Valve2.16 G ROPressure Relief Valve2.20.9 G ROExpansion Joints

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 27: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 27 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

23 64 26 2.21 G ROPumps2.20.3 G ROCombination Strainer and Pump

Suction Diffuser2.22 G ROExpansion Tanks2.23 G ROAir Separator Tanks

23 81 00.00 20 SD-02 Shop Drawings1.4.2 G AEControl System wiring diagrams

SD-03 Product DataG AERoom Air ConditionersG AEThermostats

SD-06 Test ReportsSalt-Spray Tests

3.5.3Start-up and Initial OperationalTests

SD-08 Manufacturer’s InstructionsRoom Air ConditionersFiltersThermostatsRefrigerant Piping andAccessories

SD-10 Operation and MaintenanceDataRoom Air ConditionersFiltersThermostats

SD-11 Closeout Submittals

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 28: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 28 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

23 81 00.00 20 1.4.4Posted Operating Instructions23 82 19 SD-01 Preconstruction Submittals

1.3 G AEMaterial, Equipment, and ProductInstallation Lists

SD-02 Shop Drawings3.1 G AEInstallation Drawings

SD-03 Product Data1.3 G AEEquipment and Performance

Data2.5 G AECoils2.3 G AECasing2.8 G AEMotors2.4 G AEFan2.7 G AEFilters2.9 G AEControls1.3 G AEVibration Isolation

SD-07 Certificates1.3 G ROListing of Product Installations2.5 G ROCoils2.3 G ROCasing2.8 G ROMotors2.4 G ROFan2.7 G ROFilters2.9 G ROControls

SD-10 Operation and MaintenanceData

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 29: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 29 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

23 82 19 3.3 G ROOperation and MaintenanceManuals

26 05 00.00 40 SD-01 Preconstruction Submittals3.1 G AEConduits, Raceway sand Fittings2.2 G AEWire and Cable2.3 G AESplices and Connectors2.4 G AESwitches2.5 G AEReceptacles3.4.1 G AEReceptacles2.6 G AEOutlets, Outlet Boxes, and Pull

Boxes2.8 G AECircuit Breakers2.7 G AEPanelboards3.7 G AEPanelboards2.9 G AELamps and Lighting Fixtures3.6 G AELamps and Lighting Fixtures

SD-03 Product Data3.1 G AEConduits, Raceway sand Fittings2.2 G AEWire and Cable2.3 G AESplices and Connectors2.4 G AESwitches2.5 G AEReceptacles3.4.1 G AEReceptacles2.6 G AEOutlets, Outlet Boxes, and Pull

Boxes2.8 G AECircuit Breakers

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 30: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 30 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

26 05 00.00 40 2.7 G AEPanelboards3.7 G AEPanelboards1.3 G AESpare Parts

SD-06 Test Reports3.9 G ROContinuity Test3.9 G ROInsulation Resistance Test

SD-08 Manufacturer’s Instructions1.5 G ROManufacturer's Instructions

26 05 19.00 10 SD-03 Product Data3.1Installation Instructions

SD-06 Test Reports3.2Tests, Inspections, and

Verifications26 05 71.00 40 SD-01 Preconstruction Submittals

2.4 G AEFusesSD-02 Shop Drawings

3.1 G AEControl Devices3.1 G AEProtective Devices

SD-03 Product Data2.1 G AEMotor Control2.2 G AEEnclosures2.3 G AECircuit Breakers3.1 G AEControl Devices

SD-07 Certificates2.5Circuit Tests

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 31: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 31 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

26 05 71.00 40 SD-10 Operation and MaintenanceData

2.1.1 G ROManual Motor Controllers2.1.2 G ROMagnetic Motor Controllers2.1.3 G ROCombination Motor Controllers2.3 G ROCircuit Breakers

26 24 16.00 40 SD-02 Shop Drawings1.2 G AEDetail Drawings1.2 G AEOutline Drawings

SD-03 Product Data2.1Panelboards2.3Directory Card and Holder

SD-04 Samples2.1Keys

SD-06 Test Reports3.2 G ROContinuity Tests3.2 G ROInsulation Tests

SD-07 Certificates1.2 G ROStatements

SD-08 Manufacturer’s Instructions2.1Panelboards

26 29 23 SD-02 Shop Drawings1.5.1 G AESchematic diagrams1.5.2 G AEInterconnecting diagrams1.5.3 G AEInstallation drawings

SD-03 Product Data

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 32: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 32 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

26 29 23 2.1 G AEVariable frequency drives2.3 G AEWires and cables1.5.4 G AEEquipment schedule

SD-06 Test Reports3.2.1VFD Test3.2.2Performance Verification Tests3.2.3Endurance Test

SD-08 Manufacturer’s Instructions1.5.5Installation instructions

SD-09 Manufacturer’s FieldReports

2.5.1 G AEVFD Factory Test Plan1.5.6Factory test results

SD-10 Operation and MaintenanceData

2.1 G ROVariable frequency drives27 10 00 SD-02 Shop Drawings

1.5.1.1 G AETelecommunications SpaceDrawings

SD-03 Product Data2.3 G AETelecommunications cabling2.4.2 G AEPatch panels2.5 G AETelecommunications

outlet/connector assembliesSD-06 Test Reports

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115

Page 33: SUBMITTAL REGISTER

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 33 OF 33 PAGES

Repair HVAC, Bldg 1 Chapel, VA Medical Center, Providence, RI

27 10 00 3.5.1 G AETelecommunications cablingtesting

SD-07 Certificates1.5.2.1 G AETelecommunications Contractor1.5.2.2 G AEKey Personnel1.5.2.3 G AEManufacturer Qualifications1.5.3 G AETest plan

SD-09 Manufacturer’s FieldReports

2.10.1 G AEFactory reel testsSD-10 Operation and MaintenanceData

1.9 G AETelecommunications cabling andpathway system

SUBMITTAL REGISTERCONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:SCHEDULE DATES

CONTRACTORACTION

APPROVING AUTHORITY

ACTIVITY NO

TRANSMITTAL NO

SPEC SECT

DESCRIPTION

ITEM SUBMITTED

PARAGRAPH

#

CLASSIFICATION

GOVT OR A/E REVWR SUBMIT

APPROVALNEEDED

BY

MATERIALNEEDED

BY

ACTION CODE

DATEOF

ACTION

DATE FWDTO APPR

AUTH/

DATE RCDFROM

CONTR

DATE FWDTO OTHERREVIEWER

DATE RCDFROM OTHREVIEWER

ACTION CODE

DATEOF

ACTION

MAILEDTO

CONTR/

DATE RCDFRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

VA241-12-R-0716 Project Number 650-07-115