siemens sra4 svr4.6 omn - operating manual
TRANSCRIPT
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
1/244
Operating Manual
SRA 4
SVR 4.6
OMN
911-381/02A0460Issue 1, March 2006
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
2/244
SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006
Copyright (C) Siemens S.p.A. 2006V.le Piero e Alberto Pirelli, 10I-20126 Milano
Issued by Customer Documentation Department
S.S. 11 Padana Superiore, km 158
I-20060 Cassina de Pecchi MI
DISCLAIMER
Siemens may have patents, patent applications, trademarks, copyrights, or other intellectual property rights relevant to the subject matters
present in this document.
If not explicitly defined by a license agreement written by Siemens, the ownership of this document does not give any use license for the
above mentioned patents, trademarks, copyrights, or other intellectual properties.
For your convenience, Siemens may make this document available.
The entire risk deriving from the use, or the results of the use, of this document are at users charge.
The information contained in this document is subjected to changes without notice.
Technical specifications and features are binding only insofar as they are specifically and expressly agreed previously in a written contract.
Siemens gives no assurance relevant to the accuracy of the results or of the output deriving from such information.
In case of utilization of the information transferred by means of this document, we advise You to verify if the export licenses, required by thelaws, have been granted or if there are not any other impediments arising from the laws in course in Italy, Germany or relevant to the export.
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
http://stile.pdf/http://stile.pdf/ -
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
3/244
STATUS OF MANUAL
R-1SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006
This OMN manual describes the procedures for the installation and the use of the
software plug-in for the management of SRA4 SVR 4.6. equipment.
With respect to the Issue 1, December 2005, the alarm tables in Chapter 6 and 7 have
been updated.
STATUS OF MANUAL
Current: Issue 1, March 2006
Previous: Issue 1, Dicember 2005
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
4/244
STATUS OF MANUAL
R-2SRA 4 - OMN
911-381/02A0460 - Issue 1, March 2006
BLAN
KPAGE
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
5/244
INDEX
I-1SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006
INDEX
STATUS OF MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R.1
INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I.1
LIST OF ILLUSTRATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I.5
LIST OF TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I.11
1 GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1
1.1 Subject and Purpose of the Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1
1.2 Functionalities of the Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2
1.3 Testing and Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4
1.4 Responsibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4
1.5 Conditions of the Provision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5
1.6 Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5
1.7 Lists of Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5
2 EQUIPMENT MANAGEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1
2.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.12.1.1 Local Craft Terminal (LCT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1
2.2 User Classes and Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.22.2.1 User Classes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.22.2.2 Management of the access to the network element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3
3 INSTALLATION OF PLUG-IN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1
3.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1
3.2 Installation Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1
3.3 Uninstallation of Plug-In. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3
4 COMMISSIONING VIA LCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1
5 DOWNLOAD OF CONTROLLER UNIT SOFTWARE . . . . . . . . . . . . . . . . . . . . . . . . 5.1
5.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1
5.2 Download via FTP of IDU software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2
5.3 Download via FTP of ODU software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
http://stile.pdf/http://stile.pdf/ -
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
6/244
INDEX
I-2SRA 4 - OMN
911-381/02A0460 - Issue 1, March 2006
6 OPERATING GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1
6.1 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1
6.2 Architecture of the System with Double IDU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1
6.3 Software Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.26.3.1 Plug-in Functionalities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.26.3.2 Hardware hardware key Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.36.3.2.1 Controller operating modalities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.46.3.2.2 Main/Expansion Configuration Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.56.3.2.2.1 IDU numbering in 2 IDU units based System Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.56.3.2.2.2 Main/Expansion negotiation at controller start up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.56.3.2.2.3 Loss and recovery of communication between main and expansion controllers . . . . . . . . . . . 6.56.3.2.2.4 Check of the HW and SW versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.56.3.3 License . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.66.3.4 Security. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.7
6.4 Uploading of profile. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.8
6.5 Push-buttons Key in Plug-in Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.9
6.6 Structure of the Operating Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.9
6.7 Configuration and Status of the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.106.7.1 Equipment Status & Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.116.7.1.1 System Configuration window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.176.7.1.1.1 Management of J0 byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.226.7.1.1.2 Config Type Setting window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.266.7.1.2 External Interface Setting window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.286.7.1.2.1 BB-Modem Payload window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.306.7.1.2.2 Q Interface Parameters window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.32
6.7.1.2.3 Output Commands Settings window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.336.7.1.2.4 Input Station Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.346.7.1.2.5 AUX Channel BB-Modem window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.366.7.1.3 Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.386.7.1.3.1 Protection in (1+1) and 2x(1+1) System Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.396.7.1.3.2 Protection in (N+1) System Types (starting from SVR 4.4) . . . . . . . . . . . . . . . . . . . . . . . . . . 6.426.7.1.4 Co-Channel operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.456.7.1.5 Testing window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.486.7.1.5.1 Testing Mode & Loop-Backs window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.496.7.1.5.2 Recording of the Long Period Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.516.7.1.5.3 Timed Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.546.7.1.6 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.60
6.7.1.7 Feature Control window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.616.7.1.8 Copy Config command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.626.7.1.9 Paste Config command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.636.7.1.10 BB-Modem Config window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.636.7.1.11 ATPC function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.656.7.1.11.1ATPC for ODU Narrowband. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.666.7.1.11.2ATPC for ODU Wideband . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.676.7.1.11.3Setting of the transmission power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.686.7.1.12 Configuration of ODU unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.696.7.1.12.1Configuration of Wideband ODU unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.696.7.1.12.2Configuration of Narrowband ODU unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.796.7.2 Software Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.826.7.2.1 IDU Software Banks window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.82
6.7.2.2 ODU Software Banks window (only for ODU Wideband) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.846.7.2.3 FTP Transfer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.86
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
7/244
INDEX
I-3SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006
6.7.2.4 SW Reset window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.876.7.3 Management of the network parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.876.7.3.1 Access to the dynamic routing table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.886.7.3.2 IP Address. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.89
6.7.3.3 Interface network parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.916.7.3.4 Static Routing Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.956.7.4 Configuration of the error notification thresholds. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.976.7.5 Setting of date and time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.99
6.8 Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1006.8.1 Physical and functional alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1006.8.1.1 TX Way Payload Functional Alarms window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1036.8.1.1.1 RST Tx STM-1 (BB-Modem) window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1046.8.1.2 RX Way Payload Functional Alarms window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1046.8.1.2.1 RST Rx STM-1 (BB-Modem) window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1066.8.1.3 IDU Other Functional Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1066.8.1.4 A.U. IDU User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.108
6.8.1.5 Controller IDU User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1086.8.1.6 Mem Key User Physical Alarms window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1096.8.1.6.1 Mem Key Maint Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1096.8.1.7 FAN IDU User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1106.8.1.8 BB-Modem User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1106.8.1.9 i/f User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1116.8.1.10 System User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1126.8.1.11 ODU User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1136.8.1.11.1Physical Maintenance Alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1146.8.1.12 i/f CPU User Physical Alarms window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1156.8.1.13 i/f Exp Cable User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1156.8.1.13.1i/f Exp Cable Maint Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.116
6.8.2 Alarm Thresholds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1166.8.3 Station alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.117
6.9 Management of Measurements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1186.9.1 Unit Measurements window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1186.9.2 Measurement of RX and TX ODU power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.119
6.10 Performance Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1206.10.1 RST Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1216.10.2 Unavailability Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1216.10.3 RSPI parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1226.10.4 RPS Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1236.10.5 Suspect Interval. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1246.10.6 Performance menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1256.10.7 Performance - PM Setting window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1266.10.8 Performance Monitoring View window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1296.10.8.1 RST Performance View: BB-Modem - Trib Side STM-1 (Quarter) window. . . . . . . . . . . . . . 6.1306.10.8.2 RST Performance View: BB-Modem - Trib Side STM-1 (Day) window. . . . . . . . . . . . . . . . . 6.1306.10.8.3 RST Performance View: RX Chain - Radio Side STM-1 (Quarter) window . . . . . . . . . . . . . 6.1316.10.8.4 RST Performance View: RX Chain - Radio Side STM-1 (Day) window . . . . . . . . . . . . . . . . 6.1326.10.8.5 RPS Performance View: RX Chain (Quarter) window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1326.10.8.6 RPS Performance View: RX Chain (Day) window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1336.10.8.7 RSPI Performance View: ODU Tx Side (Quarter) window . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1346.10.8.8 RSPI Performance View: ODU Rx Side (Quarter) window . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1346.10.8.9 RSPI Performance View: ODU (Day) window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.135
6.11 Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1366.11.1 PID window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.138
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
8/244
INDEX
I-4SRA 4 - OMN
911-381/02A0460 - Issue 1, March 2006
6.11.2 Management of the user inventory data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1386.11.3 Equipment Software window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1396.11.4 About window (NetViewer/LCT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1396.11.5 Report. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.140
6.12 Security. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.142
6.13 NE Severity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1446.13.1 Critical. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1456.13.2 Major. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1496.13.3 Minor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1536.13.4 Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.154
7 ALARM MANAGEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1
7.1 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1
7.2 Summary Alarm Signalings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1
7.3 Alarm Signaling via Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1
A LICENSE UPGRADE PROCEDURE FOR SRA4 EQUIPMENT . . . . . . . . . . . . . . . . . A.1
A.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.1
A.2 Upgrading Procedure Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.2
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
9/244
I-5SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006
LIST OF ILLUSTRATIONS
LIST OF ILLUSTRATIONS
Fig. 2.1 IDU unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2Fig. 3.1 Installation of plug-in (1/2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2Fig. 3.2 Installation of plug-in (2/2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2Fig. 5.1 Download procedure of IDU software via FTP (1/5). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2Fig. 5.2 Download procedure of IDU software via FTP (2/5). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3Fig. 5.3 Download procedure of IDU software via FTP (3/5). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3Fig. 5.4 Download procedure of IDU software via FTP (4/5). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4Fig. 5.5 Download procedure of IDU software via FTP (5/5). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4Fig. 5.6 IDU Software Banks window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5Fig. 5.7 Download procedure of ODU software via FTP (1/5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6Fig. 5.8 Download procedure of ODU software via FTP (2/5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.7
Fig. 5.9 Download procedure of ODU software via FTP (3/5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.7Fig. 5.10 Download procedure of ODU software via FTP (4/5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.8Fig. 5.11 Download procedure of ODU software via FTP (5/5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.8Fig. 5.12 ODU Software Banks window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.9Fig. 6.1 Example of map with SRA4 equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.8Fig. 6.2 Operating menu of SRA 4 equipment plug-in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.10Fig. 6.3 Status and Config Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.11Fig. 6.4 Equipment Status & Configuration window (e.g.: 2x(1+1) FD DTI System Type) . . . . . . . . . . . . . 6.12Fig. 6.5 System Configuration window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.17Fig. 6.6 Configuration of System Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.18Fig. 6.7 Configuration of modulation and capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.19Fig. 6.8 Configuration of Radio Channel Destination. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.20Fig. 6.9 Configuration of Alarm unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.20
Fig. 6.10 Configuration of Controller unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.20Fig. 6.11 Configuration of FAN unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.20Fig. 6.12 Configuration of BB-Modem unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.21Fig. 6.13 Configuration of ODU unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.21Fig. 6.14 Link ID (J0) BB-Modem1 window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.23Fig. 6.15 Configuration of TIM alarm activation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.23Fig. 6.16 Configuration of TIM alarm deactivation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.23Fig. 6.17 Window for the J0 Management Tributary Side (TX) selection . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.24Fig. 6.18 Window for enabling/disabling AIS Insertion for TIM (Tributary Side) . . . . . . . . . . . . . . . . . . . . . . 6.24Fig. 6.19 Window for the insertion of J0 Inserted Tributary Side. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.24Fig. 6.20 Window for the J0 Expected Tributary Side insertion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.25Fig. 6.21 Window for the J0 Management Radio Side (Rx) selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.25
Fig. 6.22 Window for the AIS Insertion for TIM (Rx) enabling/disabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.25Fig. 6.23 Window for the J0 Inserted Radio Side insertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.26Fig. 6.24 Window for the J0 Expected Radio Side insertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.26Fig. 6.25 Config Type Setting window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.27Fig. 6.26 Configuration of Config Type Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.27Fig. 6.27 External Interface Setting window (System Type: 2x(1+1) FD DTI) . . . . . . . . . . . . . . . . . . . . . . . . 6.28Fig. 6.28 Configuration of Automatic Laser Shut Down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.29Fig. 6.29 Configuration of Masking STM-1 #2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.30Fig. 6.30 BB-Modem Payload window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.30Fig. 6.31 Configuration of Laser Restart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.31Fig. 6.32 Configuration of the Laser Forcing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.31Fig. 6.33 Q Interface Parameters window (write modality) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.32Fig. 6.34 Configuration of Bit-Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.33Fig. 6.35 Configuration of Electrical i/f Duplexing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.33
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
http://stile.pdf/http://stile.pdf/ -
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
10/244
I-6SRA 4 - OMN
911-381/02A0460 - Issue 1, March 2006
LIST OF ILLUSTRATIONS
Fig. 6.36 Output Command Settings window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.33Fig. 6.37 Output Command description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.34Fig. 6.38 Enabling of Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.34Fig. 6.39 Station Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.34
Fig. 6.40 Name/descripiton configuration window for station alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.35Fig. 6.41 Configuration of Polarity Alarm 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.35Fig. 6.42 AUX Channel BB-Modem window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.36Fig. 6.43 Configuration of Service Channel Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.36Fig. 6.44 Configuration of Enable 64 kb/s V11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.36Fig. 6.45 Configuration of Enable 64 kb/s G703. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.37Fig. 6.46 Configuration of Way Side (WS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.37Fig. 6.47 AUX Channel IDU #1 BB-Modem 1 window (example). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.37Fig. 6.48 Configuration of F1 byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.38Fig. 6.49 Configuration of Way Side (WS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.38Fig. 6.50 Protection Status & Configuration window (System Type 2x(1+1) FD DTI) . . . . . . . . . . . . . . . . . 6.39Fig. 6.51 Configuration of Switching Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.40
Fig. 6.52 Configuration of Switch Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.40Fig. 6.53 Configuration of Trib Forcing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.41Fig. 6.54 Configuration of ODU Forcing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.41Fig. 6.55 Configuration of Dem Forcing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.41Fig. 6.56 Protection Status & Configuration window ((3+1) System Types). . . . . . . . . . . . . . . . . . . . . . . . . 6.42Fig. 6.57 Configuration of Switching Criteria Enabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.43Fig. 6.58 Configuration of Remote Tx Prioritary Ch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.43Fig. 6.59 Configuration of Switch Priority Ch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.44Fig. 6.60 Configuration of Switch Criteria Forcing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.44Fig. 6.61 Co-Channel window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.46Fig. 6.62 Configuration of synchronization modality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.47Fig. 6.63 Synch Forcing window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.47Fig. 6.64 Configuration of Synch Forcing (CC). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.47Fig. 6.65 Configuration of Polarization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.48Fig. 6.66 Testing window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.48Fig. 6.67 Testing Mode & Loop-Backs window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.49Fig. 6.68 Configuration of Loop-Back Trib Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.50Fig. 6.69 Configuration of Loop-Back Trib Side INT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.50Fig. 6.70 Configuration of Loop-Back Radio Side EXT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.50Fig. 6.71 Configuration of Modulator Mode BB-Modem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.51Fig. 6.72 Testing - Long PM Recording window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.51Fig. 6.73 Long period PM recording . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.52Fig. 6.74 Configuration of Recording Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.52Fig. 6.75 Configuration of recording start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.52Fig. 6.76 Enabling/disabling of the recording . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.53
Fig. 6.77 Configuration of Timed Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.55Fig. 6.78 Single Timed Switching window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.56Fig. 6.79 Configuration of Switch Starting Position (example: ODU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.57Fig. 6.80 Example of Single Timed Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.57Fig. 6.81 Periodic Timed Switching window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.58Fig. 6.82 Example of Periodic switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.59Fig. 6.83 Maintenance window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.60Fig. 6.84 Feature Control window (write modality) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.61Fig. 6.85 Configuration of License Key #1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.61Fig. 6.86 BB-Modem Config window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.63Fig. 6.87 Configuration of Cable Length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.64Fig. 6.88 Configuration of IF Output Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.64
Fig. 6.89 Configuration of TX Mod Spectrum Inversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.65Fig. 6.90 Configuration of XPIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.65
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
11/244
I-7SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006
LIST OF ILLUSTRATIONS
Fig. 6.91 ODU Config window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.66Fig. 6.92 Hysteresis cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.66Fig. 6.93 Linear ATPC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.68Fig. 6.94 ODU Config window (Freq Mode = Continuous) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.69
Fig. 6.95 ODU Config window (Freq Mode = Continuous) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.70Fig. 6.96 ODU Config window (Freq Plan Activation = On). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.70Fig. 6.97 Configuration of Freq Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.71Fig. 6.98 Frequency plan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.71Fig. 6.99 Enabling/disabling of Freq Plan Activation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.72Fig. 6.100 Configuration of Channel Spacing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.73Fig. 6.101 Configuration of TX Freq Ch#1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.73Fig. 6.102 Configuration of First Channel ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.73Fig. 6.103 Configuration of Last Channel ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.74Fig. 6.104 Configuration of RF Channel ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.74Fig. 6.105 Configuration of TX Freq . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.74Fig. 6.106 Configuration of RX Freq . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.74
Fig. 6.107 Configuration of Pmin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.75Fig. 6.108 Configuration of ATPC Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.75Fig. 6.109 Configuration of ATPC Threshold. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.75Fig. 6.110 Configuration of ATPC Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.76Fig. 6.111 Configuration of Squelch SW Activation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.76Fig. 6.112 Configuration of Comp IF Cable Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.77Fig. 6.113 Configuration of the cable compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.77Fig. 6.114 Warning for temporary loss of the payload in transmission (Tx AGC) . . . . . . . . . . . . . . . . . . . . . . 6.78Fig. 6.115 Configuration of Tx AGC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.78Fig. 6.116 Warning for temporary loss of the payload in reception (IF Power RX) . . . . . . . . . . . . . . . . . . . . . 6.78Fig. 6.117 Configuration of IF Power (Rx) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.78Fig. 6.118 Configuration of IF Attenuation (Tx) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.79Fig. 6.119 ODU Config window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.79Fig. 6.120 Configuration of ATPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.80Fig. 6.121 Configuration of TX Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.80Fig. 6.122 Configuration of ATPC Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.80Fig. 6.123 Configuration of ATPC Threshold 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.81Fig. 6.124 Configuration of Nominal Power Level Setting Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.81Fig. 6.125 Configuration of Nominal Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.81Fig. 6.126 Software menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.82Fig. 6.127 IDU Software Banks window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.83Fig. 6.128 IDU Software Banks window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.83Fig. 6.129 ODU Software Banks window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.85Fig. 6.130 Warning for payload loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.85Fig. 6.131 Warning for not compatible SW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.86
Fig. 6.132 Software Reset window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.87Fig. 6.133 Network menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.87Fig. 6.134 Directory tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.88Fig. 6.135 Structure of table.txt file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.88Fig. 6.136 Example of routing table seen by FTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.89Fig. 6.137 IP Address window (write modality) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.90Fig. 6.138 Configuration of IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.91Fig. 6.139 Configuration of Net Mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.91Fig. 6.140 NE Parameters window (with ETH MTU = default value). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.92Fig. 6.141 Configuration of ETH MTU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.93Fig. 6.142 NE Parameters window with ETH MTU field set to Other . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.93Fig. 6.143 Window for the insertion of an arbitrary value of ETH MTU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.93
Fig. 6.144 Enabling/disabling of the Telnet port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.94Fig. 6.145 Configuration of RIPv1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.94
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
12/244
I-8SRA 4 - OMN
911-381/02A0460 - Issue 1, March 2006
LIST OF ILLUSTRATIONS
Fig. 6.146 Static Routing Table window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.96Fig. 6.147 Configuration of Destination Network Routing Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.96Fig. 6.148 Configuration of Subnet Mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.97Fig. 6.149 Configuration of Gateway Routing Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.97
Fig. 6.150 Configuration of Metric. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.97Fig. 6.151 TCN - Threshold Settings window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.98Fig. 6.152 Configuration of B1 Threshold for SD alarm (tributary side) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.98Fig. 6.153 Configuration of B1 Threshold for SD alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.98Fig. 6.154 Date & Time window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.99Fig. 6.155 Alarms menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.100Fig. 6.156 Physical and Functional Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.101Fig. 6.157 TX Way Payload Functional Alarms window (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.103Fig. 6.158 RST Tx STM-1 (BB-Modem) window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.104Fig. 6.159 RX Way Payload Functional Alarms window (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.105Fig. 6.160 RST Rx STM-1 (BB-Modem) window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.106Fig. 6.161 IDU Other Functional Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.107
Fig. 6.162 A.U. IDU User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.108Fig. 6.163 Controller IDU User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.108Fig. 6.164 Mem Key User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.109Fig. 6.165 Mem Key Maint Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.109Fig. 6.166 FAN IDU User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.110Fig. 6.167 BB-Modem User Physical Alarms window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.111Fig. 6.168 User Physical Alarms - IDU-ODU i/f window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.111Fig. 6.169 System User Physical Alarms window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.112Fig. 6.170 ODU User Physical Alarms window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.113Fig. 6.171 ODU Maint Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.114Fig. 6.172 ODU Maint Physical Alarms window - Wideband ODU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.114Fig. 6.173 i/f CPU User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.115Fig. 6.174 i/f Exp Cable User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.116Fig. 6.175 i/f Exp Cable Maint Physical Alarms window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.116Fig. 6.176 TCN - Alarm Threshold window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.117Fig. 6.177 Station Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.117Fig. 6.178 Measurements menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.118Fig. 6.179 Unit Measurements window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.118Fig. 6.180 Measurement - Record menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.120Fig. 6.181 Performance menu (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.125Fig. 6.182 Performance PM Setting window - Common Thresholds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.126Fig. 6.183 Performance PM Setting window - Independent Thresholds. . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.127Fig. 6.184 Configuration of RSPI Thresholds Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.128Fig. 6.185 Configuration of RLT ODU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.128Fig. 6.186 Configuration of TLT ODU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.128
Fig. 6.187 Performance Monitoring View window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.129Fig. 6.188 RST Performance View: BB-Modem Trib Side (Quarter) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.130Fig. 6.189 RST Performance View: BB-Modem Trib Side (Day) window . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.131Fig. 6.190 RST Performance View: RX Chain - Radio Side STM-1 (Quarter) window. . . . . . . . . . . . . . . . . 6.131Fig. 6.191 RST Performance View: RX Chain - Radio Side STM-1 (Day) window . . . . . . . . . . . . . . . . . . . 6.132Fig. 6.192 RPS Performance View: RX Chain (Quarter) window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.133Fig. 6.193 RPS Performance View: RX Chain (Day) window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.133Fig. 6.194 RSPI Performance View: ODU - Tx Side (Quarter) window . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.134Fig. 6.195 RSPI Performance View: ODU - Rx Side (Quarter) window . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.135Fig. 6.196 RSPI Performance View: ODU (Day) window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.136Fig. 6.197 Inventory window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.137Fig. 6.198 PID window (e.g.: Controller). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.138
Fig. 6.199 USER window (e.g.: Controller). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.138Fig. 6.200 User Inventory window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.139
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
13/244
I-9SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006
LIST OF ILLUSTRATIONS
Fig. 6.201 Equipment Software window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.139Fig. 6.202 About NetViewer window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.140Fig. 6.203 About LCT window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.140Fig. 6.204 Security window (Admin user class) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.142
Fig. 6.205 Window to enable the Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.142Fig. 6.206 Field Editing for the insertion of the new password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.143
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
14/244
I-10SRA 4 - OMN
911-381/02A0460 - Issue 1, March 2006
LIST OF ILLUSTRATIONS
BLAN
KPAGE
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
15/244
LIST OF TABLES
I-11SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006
LIST OF TABLES
Tab. 6.1 Description of the push-buttons in the plug-in window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.9Tab. 6.2 Laser operating rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.31Tab. 6.3 Independent switches depending on System Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.54Tab. 6.4 ATPC management (ODU Narrowband) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.66Tab. 7.1 Functional Alarms: description and severity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.2Tab. 7.2 Physical Alarms: description and severity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.4Tab. A.1 License Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A.1
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
http://stile.pdf/http://stile.pdf/ -
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
16/244
LIST OF TABLES
I-12SRA 4 - OMN
911-381/02A0460 - Issue 1, March 2006
BLAN
KPAGE
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
17/244
1 - GENERAL INFORMATION
1-1SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006
1 GENERAL INFORMATION
1.1 Subject and Purpose of the Manual
SRA4 is a STM-1 and 2xSTM-1 radio communication equipment for point-to-point
applications, using an high frequency indoor-outdoor architecture, designed to transfer
the SDH/SONET signals. SRA4 radio equipment is managed using the extended TNMP
protocol; the network protocol is TCP/IP.
SRA4 radio equipment is built up by:
one or two indoor shelves (IDU, indoor unit), providing the base band;
from one to four outdoor equipment (ODU, outdoor unit), containing RF devices.
ODU units are connected with the IDU by means of an IF cable;
one heater sub-unit on the outdoor equipment (optional).
The IDU deals with all the digital interfaces and performs a first frequency conversion
to/from IF signals which are transmitted to the ODU.
The ODU performs signal amplification and frequency up/down conversion to/from the
millimeter-wave frequency.
The configuration of the indoor shelf and the ways controller card programs the slave
cards are different according to the selected system type and configuration. In addition,
system provisioning and management are available using local connection via standardRS-232 connection (F interface) or via 10 Base T Ethernet connection (Q interface).
This OMN manual provides the necessary instructions for the management, via PC, of
the SRA4 digital radio equipment with SVR 4.6. The management via software of the
equipment with SVR 4.6 can be executed as by NetViewer 7.0 (management system of
radio networks) as by LCT 6.1 (management system of the local terminal and/or of the
radio link).
For a detailed description of the units present in the system, refer to the UMN
manual of SRA4 equipment.
For the using modes of NetViewer/LCT, refer to the relevant operating guide.
Without a written authorization, it is forbidden to forward to third parties the
contents of the subject Manual.
The Customer can require a copy of the subject manual pointing out its code
(present on the cover rear-page).
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
18/244
1 - GENERAL INFORMATION
1-2SRA 4 - OMN
911-381/02A0460 - Issue 1, March 2006
1.2 Functionalities of the Equipment
The equipment SVR 4.6 supports the following functionalities:
Managed System Types:
1+0 w/o MST
1+1 Hot Stand-by w/o MST Single Tributary Interface
1+1 Hetero frequency w/o MST Single Tributary Interface
1+1 Hot Stand-by w/o MST Double Tributary Interface
1+1 Hetero frequency w/o MST Double Tributary Interface
2x(1+1) Frequency Diversity w/o MST Single Tributary Interface
2x(1+1) Frequency Diversity w/o MST Double Tributary Interface
2x(1+1) Hot Stand-by w/o MST Single Tributary Interface
2x(1+1) Hot Stand-by w/o MST Double Tributary Interface
2+0 w/o MST (with independent configuration of the two basebands)
2+1 w/o MST 3+1 w/o MST
Equipment traffic capacity
Tributary capacity: STM-1 or 2xSTM-1
Digital service channels: 2.048 Mbit/s (G.703) Way-Side
Auxiliary Data Channels: 64 Kbit/s V.11 or 64 Kbit/s G.703
Base-band interface:
STM-1 electrical ITU-T G.703
STM-1 optical ITU-T G.957 S-1.1
Modulation type
32 TCM + Reed-Solomon Concatenated Coding 128 TCM + Reed-Solomon Concatenated Coding
Pattern type:
AP (Alternate Polarization)
CC (Co-Channel)
ODU type
Narrowband
Wideband
Available loop-back types
Radio side up to tributary section
Tributary side up to tributary physical interface
Tributary side up to the modem interface
1+1 protection
RX radio side
TX tributary side
TX radio side
Control of the transmission power
ODU Narrowband. 2 ATPC levels (Pnom, Pnom-8). Range: 8 dBm
ODU Wideband. Linearized for ODU Wideband
Possibility of independent configuration of the BB-Modem units in the (2+0) System
Type without MST
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
19/244
1 - GENERAL INFORMATION
1-3SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006
Configuration of the operating parameters
Transmission and reception frequency
Transmission power (ATPC)
Alarm parameters
Remote controls
Local loop-back (from LCT)
User channels (byte F1/ byte S(2,3))
ALS (Automatic Laser Shutdown)
Laser restart
Configuration of the co-channel operation
Management of J0 byte
Configuration of the error thresholds (TCN)
Measures
ODU transmitted power
RF RX power
Recordings
Performance Monitoring (independent counters for each measurement point)
Events
Report of inventory data
Alarms management
Diagnostics
Input of station alarms (max. 4)
System alarms restitution (max. 8)
Signalling of alarm threshold crossing
Software download
Local/remote download of the equipment software Switching of the Controller banks
Copy of the active banks of the Controller
Alignment of the unit software
License management
Management of the hardware key
Management of the inventory data
hardware data (unit PID data, user data)
software data
Support of the TNMP protocol (base and extended) as management application
protocol
Management system
Local supervision of NEs and of the radio link via LCT
Remote supervision of the NEs of the radio network via NetViewer
Networking functions
RIPv1 protocol for the transport of the routing information
Propagation of static routing table
Notification of the dynamic routing table
Border Gateway
Ingress Summarization
Configuration of TCP/IP connection IP address
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
20/244
1 - GENERAL INFORMATION
1-4SRA 4 - OMN
911-381/02A0460 - Issue 1, March 2006
Static routing tables
Net-mask
configurable Ethernet MTU (Maximum Transfer Unit)
Management interfaces F interface (RS-232) for the serial connection to LCT
Q interface (10/100 Base T) for the connection to LAN network
E interface (10 Base T) for the connection between the two IDUs in a system
with double IDU
Use of SOH bytes
Byte S23 as auxiliary channel
Byte S22 as ATPC channel
Byte S32 as management channel (R)
Management of Controller unit
Selection of the active memory bank
Software download from local PC or via remote
Equipment commissioning (with recording of the relevant performance) and
periodic tests
Local History Log (storing of the last events occurred on the equipment)
Switch of the synchronism source of the STM-1s for MS-AIS alarm (in case of
2xSTM-1 capacity)
Replacement of the alarm unit without traffic loss (only for the proper hardware
version of the 2xSTM-1 unit).
1.3 Testing and Warranty
Refer to the contract clauses for the information about testing and warranty.
1.4 Responsibility
Refer to the contract clauses for the information about the subject matter.
Besides it is necessary to observe that:
the manufacturer declines all responsibilities deriving from the incorrect or wronguse of the equipment, from the utilization of unauthorized parts and circuit,
component and system software violations.
the responsibility for the application of safety rules and use prescriptions is
entrusted to the technical personnel responsible for the various activities, which
has to make sure that the authorized personnel is qualified to perform the
requested activity and has the required knowledge.
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
21/244
1 - GENERAL INFORMATION
1-5SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006
1.5 Conditions of the Provision
The SRA4 plug-in is provided on CD-ROM and is included, together with the LCT
program, into the equipment provision.The equipment CD-ROM includes:
the LCT program for the management of the radio link and/or of the local radio
equipment
the SRA4 plug-in.
The SRA4 plug-in can be included on demand into the CD-ROM of NetViewer.
1.6 Related Manuals
For the SRA4 equipment, the following manuals are available:
User Manual (UMN)
It contains the necessary informations for the equipment installation, the
commissioning and the maintenance.
Operating Manual (OMN)It contains the necessary informations for the equipment configuration and control
by means of PC.
LCT 6.1 (OMN)
It contains the necessary informations for the configuration and control, by means
of a service PC, of SRA4 link and of the relative equipments.
NetViewer (OMN)
It contains the necessary informations for the configuration and control, by means
of a network PC, of SRA4 network and of each network equipments.
All the manuals are available in English; they can be also provided in other languages,
depending on the contract clauses.
1.7 Lists of Abbreviations
AGC
Automatic Gain Control
AIS
Alarm Indication Signal
ALS
Automatic Laser Shutdown
The plug-ins available on the CD-ROM of NetViewer depend on the provision
conditions of NetViewer.
By default, the plug-ins for Cisco router and generic SNMP device are always
available.All the other plug-ins are provided only on demand.
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
22/244
1 - GENERAL INFORMATION
1-6SRA 4 - OMN
911-381/02A0460 - Issue 1, March 2006
ALM
Alarm
AP
Alternate PatternATM
Asynchronous Transport Mode
ATPC
Automatic Transmission Power Control
AUX
Auxiliary
BB
Base Band
BBE
Background Block Errors
BER
Bit Error Rate
CC
Co-Channel
CH
Channel
CON
Connected
CPUCentral Processing Unit
CRC
Cyclic Redundancy Check
Dem
Demodulator
DIS
Disconnected
DTI
Double Tributary Interface
EEPROM
Electrically Erasable Programmable Read Only Memory
EM
Element Manager
ES
Errored Seconds
ETSI
European Telecommunications Standard Institute
EW
Early Warning
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
23/244
1 - GENERAL INFORMATION
1-7SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006
FD
Frequency Diversity
FERF
Far End Receive FailureFPGA
Field Programmable Gate Array
FSK
Frequency Shift Keying
FSRC
Failed Switch Request Count
FSRD
Failed Switch Request Duration
FTP
File Trasfer Protocol
Gnd
Ground
HBER
High Bit Error Ratio
HEX
Hexadecimal
HF
Hetero Frequency
HSBYHot Stand-by
HW
Hardware
I/O
Input/Output
ID
Identifier
IDU
InDoor Unit
i/f
Interface
IF
Intermediate Frequency
IN
Input
IP
Internet Protocol
LCT
Local Craft Terminal
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
24/244
1 - GENERAL INFORMATION
1-8SRA 4 - OMN
911-381/02A0460 - Issue 1, March 2006
LED
Light Emission Diode
LOF
Loss Of FrameLOP
Loss Of Pointer
LOS
Loss Of Signal
MIB
Management Information Base
MIS
Mismatch
MOD
Modulator
MS
Multiplex Section
MSOH
Multiplex Section OverHead
MST
Multiplex Section Termination
NE
Network Element
ODUOutDoor Unit
OI
Outage Intensity
OMN
Operating Manual
OnL
On line
OUT
Output
PC
Personal Computer
PID
Product Identification Data
PM
Performance Monitoring
PS
Power Supply
PSAC
Protection Switch Actual Count
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
25/244
1 - GENERAL INFORMATION
1-9SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006
PSAD
Protection Switch Actual Duration
PWR
PowerRAM
Random Access Memory
RDI
Remote Defect Indication
RF
Radio Frequency
RFCOH
Radio Frequency Customer OverHead
RIP
Routing Information Protocol
RL
Received Level
RLTS
Received Level Threshold Second
RPS
Radio Protection Switching
RSOH
Regenerator Section OverHead
RSPIRegenerator Section Physical Interface
RST
Regenerator Section Termination
RX
Reception
R/O
Read Only
R/W
Read Write
SCS
Switching Control Signal
SD
Signal Degrade
SDH
Synchronous Digital Hierarchy
SES
Severely Errored Seconds
SOH
Section OverHead
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
26/244
1 - GENERAL INFORMATION
1-10SRA 4 - OMN
911-381/02A0460 - Issue 1, March 2006
SONET
Synchronous Optical Network
SPI
SDH Physical InterfaceSRA
Synchronous Radio Access
S.T.
System Type
Stby
Stand-by
STI
Single Tributary Interface
STM
Synchronous Transfer Module
SVR
Software Version Release
SW
Software
TCM
Trellis Code Modulation
TCN
Threshold Crossing Notification
TCPTransmission Control Protocol
TF
Transmission Frequency
TIM
Trail Identifier Mismatch
TL
Transmitted Level
TLTS
Transmitted Level Threshold Second
TMN
Telecommunications Management Network
TNMP
Telecommunications Network Management Point
TP
Termination Point
TRIB
Tributary
TX
Transmission
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
27/244
1 - GENERAL INFORMATION
1-11SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006
UAS
UnAvailability Seconds
UHF
Ultra High FrequencyWS
Way-Side
XPIC
Cross Polarity Interference Canceller
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
28/244
1 - GENERAL INFORMATION
1-12SRA 4 - OMN
911-381/02A0460 - Issue 1, March 2006
BLAN
KPAGE
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
29/244
2 - EQUIPMENT MANAGEMENT
2-1SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006
2 EQUIPMENT MANAGEMENT
2.1 Introduction
This manual describes the graphic user interface to manage the SRA4 equipment. The
same graphic interface is specified for the LCT and the telecommunication network
management.
The configuration of a Network element (NE) can be managed either locally by the Local
Terminal or remotely by the EM. The user interface of the EM is aware of the constrains
related to the System Type and doesnt allow any illegal configuration. The NEController is aware of these constrains too and checks the configurations imposed either
by the Local Terminal or by the EM.
In order to avoid problems due to these duplicated checks, the remote configuration of
a NE shall be managed according the following procedure:
the EM shall write the right System Type value for the NE in the NE Controller;
the NE Controller shall use this information to set the NE expected configuration to
a default configuration containing all the mandatory units and to program the actual
slave units to perform the functionalities implied by the System Type;
the EM can then modify the configuration of the optional units and, if necessary,
the type of the mandatory units.
EM doesnt allow to remove a mandatory unit without a previous change in the System
Type.
2.1.1 Local Craft Terminal (LCT)
LCT is a local personal computer which the operator uses to dialogue with the SRA4
equipment. By means of LCT it is possible to modify and configure up to three SRA4 at
the same time.
It is used for the following activities:
lining up,in order to start in service and check the equipment before its connection to the
network;
operation and maintenance,
to allows the local access to the operator for the monitoring of the system and, at
the same time, to modify the system configuration, if necessary. If the connection
between the network manager and the SRA4 equipment is not possible (for
hardware or software troubles), however LCT allows the system management.
The connection between system and the local PC takes place by means of a RS-232
V.24/V.28 interface. Its physical access is located on the main board in the IDU unit and
allows a local access to the system. For the connection between LCT and SRA4
equipment, a D-9 female connector is used to implement the RS-232 interface.
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
30/244
2 - EQUIPMENT MANAGEMENT
2-2SRA 4 - OMN
911-381/02A0460 - Issue 1, March 2006
To realize the connection via RS-232 to the SRA4 equipment, it is necessary to run from
PC a direct connection with 38400 bps bit rate.
By means of the local terminal, it is possible to set and modify the following parameters:
NE address;
the system type, stored in the EEPROM key;
the type of the equipped units;
the Modulator Mode;
the loopbacks.
Fig. 2.1 IDU unit
2.2 User Classes and Security
2.2.1 User Classes
The user classes foreseen to access the system are the following ones:
Anonymous (Security disabled) Admin User (administrator)
Read Write User (read/write user)
Read Only User (read only user)
The user login class restricts the operations allowed to the user, as specified here below:
read only users can only read, but not change, any system configuration;
Q interface is used only by NetViewer management program.
The Anonymous user class is present only for the access via LCT.
Alarm unit hardware key FAN unit BB-Modem#1 unit
Controller unit BB-Modem#2 unit
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
31/244
2 - EQUIPMENT MANAGEMENT
2-3SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006
in addition to the previous class rights, read write users can also write the
read/write the configuration parameters, but they cannot modify the password of
any user class;
in addition to the previous class rights, administrator users can also modify thepasswords for the administrator, normal and readonly user class.
Before starting the operations with the NE, either the Local Terminal Operator or the EM
Application must login to the NE, giving to the NE controller the user login class and the
password for that class. Transmission of the protocol passwords is encrypted.
The Local Terminal operator must enter the user login class at which he wants to
operate and the relevant password. Therefore the identity of the local operator is
unknown in the NE: the NE controller knows only the login class of the operator.
2.2.2 Management of the access to the network element
The concurrent access to the network element is achieved by allowing no more than one
user with user login class Anonymous, Admin User, ReadWrite User can login to the NE
at the same time. In this way, only one user at a time can modify the NE configuration.
If an user attempts to log onto the NE with user login class Anonymous, Admin User,
ReadWrite User while another user with writing rights is already logged, the log on is still
accepted, but the rights of the new user are restricted to those of user login class Read
Only.
The NE controller will record an event whenever an user with user login class
Anonymous, Admin User, ReadWrite User login or logout onto the NE. In order to
change the user login class, an user must first disconnect and then reconnect during the
login with the new user class.
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
32/244
2 - EQUIPMENT MANAGEMENT
2-4SRA 4 - OMN
911-381/02A0460 - Issue 1, March 2006
BLAN
KPAGE
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
33/244
3 - INSTALLATION OF PLUG-IN
3-1SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006
3 INSTALLATION OF PLUG-IN
3.1 Overview
The application program for the control and management of SRA4 equipment is a
plug-in of the program for the management of SRA4 network/link.
The NetViewer/LCT program is able to acknowledge and, then, manage only the radio
equipments, whose plug-in has been previously installed.
To install the plug-in software, the NetViewer/LCT program must be already installed;
otherwise, first it is necessary to install the NetViewer/LCT program and, only after,install the plug-in software.
The installation of plug-in software determines:
the possibility for NetViewer/LCT program to manage SRA4 radio equipment;
the addition of the help, relative to SRA4 management application, to the Help
menu of NetViewer/LCT program.
3.2 Installation Procedure
The plug-in can be installed during the setup of NetViewer/LCT or added/replaced later;
in this case, the procedure for the installation of the plug-in software related to SRA4
equipment is the following one:
Start the installation of the SRA4 plug-in (file ..\Disk1\setup.exe). If a plug-in
version is already installed, the system requires a confirmation to continue with the
installation and, then, continue and replace the already installed version.
The Welcomewindow opens on the screen (Fig. 3.1).
Click on Nextbutton to start the installation.
At the end of installation, the Setup Completewindow (Fig. 3.2) opens. Click on
Finishbutton to close and exit.
For more informations about the NetViewer and LCT programs, refer to the related
operating guide.
If NetViewer/LCT is already running, it is necessary to exit from it.
After the installation of the plug-in, it is necessary to restart NetViewer/LCT, if
already running, to apply the changes.
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
34/244
3 - INSTALLATION OF PLUG-IN
3-2SRA 4 - OMN
911-381/02A0460 - Issue 1, March 2006
Fig. 3.1 Installation of plug-in (1/2)
Fig. 3.2 Installation of plug-in (2/2)
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
35/244
3 - INSTALLATION OF PLUG-IN
3-3SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006
3.3 Uninstallation of Plug-In
For the uninstallation of the plug-in, no special procedure is required; then follow the
typical uninstallation modality of a Microsoft Windows application (Add/RemoveProgramsin Control Panel).
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
36/244
3 - INSTALLATION OF PLUG-IN
3-4SRA 4 - OMN
911-381/02A0460 - Issue 1, March 2006
BLAN
KPAGE
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
37/244
4 - COMMISSIONING VIA LCT
4-1SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006
4 COMMISSIONING VIA LCTThis Chapter lists all the configuration and activation operations which must be executed
via LCT for the commissioning of the equipment.
The sequence of the operations is decribed by means of a step-by-step procedure; for
each operation, the heading of the table (upper cell on the right of the title) shows the
paragraph of the operating guide which you have to refer to in order to get more details.
Before starting the commissioning procedure, execute the following preliminary
operations:
Connect the LCT to the F interface of the equipment.
Check that the hardware key is inserted before switching on the equipment.
The IDU is provided with a hardware key, where the configuration of the equipment is
stored to allow an easy and fast replacement of the Controller.
The hardware key has the following characteristics:
it is the key for the backup of the equipment configuration; each modification of a
configuration parameter is stored in the non volatile memory of the Controller and
immediately also in the non volatile memory of the hardware key (EEPROM) it is identified by:
serial number, which is univocal
the equipment type
it is strictly associated, after the switching on, to the equipment controller (the
Controller stores the serial number of the hardware key)
it contains the licence; the hardware key provided with the equipment contains the
licence ordered by the Customer.
Also a maintenance key is available (Repair Key), to be used only in case of fault to the
hardware key provided with the equipment. In the Repair Key there is stored only its own
serial number.
INTERFACE FOR THECONNECTION TO LCT
HARDWARE KEY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY
-
7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual
38/244
4 - COMMISSIONING VIA LCT
4-2SRA 4 - OMN
911-381/02A0460 - Issue 1, March 2006
Diagnostics of the hardware key
For the diagnostics of the hardware key, the following diagnostic signalings via software
are available:
Key Missing or Key MismatchThis signaling is displayed in one of the two cases:
the hardware key is disconnected. The controller detects, by means of a
dedicated sensor, the availability of the memeory key. If the detection fails,
the hardware key is disconnected
the inserted key is not valid or it belongs to a different equipment.
Key Fault
The hardware key is fault or it is not accessible: the configurations stored in the non
volatile memory of the controller are used.
Statuses of the Controller
The Controller of the equipment can assume one of the following operating statuses:
No Setting Mode
the external and internal interfaces are enabled; only reading operations are
allowed. All the configuration settings are refused.
Halt mode
the controller does not execute any action. It refuses also the connection to LCT.
To exit from this status, it is only possible to reset the controller or switch off the
equipment (the correct hardware key must be inserted).
Start-up of Controller
The Controller executes the same actions made after a software reset, a bank switchingor a switching of the IDU unit. As soon as the embedded software exits from the boot
phase, it controls the hardware key.
if the hardware key is disconnected, the system enters in the status of Halt Mode
if the hardware key is faulted, the system enters in the No Setting