    Operating Manual

    SRA 4

    SVR 4.6

    OMN

    911-381/02A0460Issue 1, March 2006

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    2/244

    SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006

    Copyright (C) Siemens S.p.A. 2006V.le Piero e Alberto Pirelli, 10I-20126 Milano

    Issued by Customer Documentation Department

    S.S. 11 Padana Superiore, km 158

    I-20060 Cassina de Pecchi MI

    DISCLAIMER

    Siemens may have patents, patent applications, trademarks, copyrights, or other intellectual property rights relevant to the subject matters

    present in this document.

    If not explicitly defined by a license agreement written by Siemens, the ownership of this document does not give any use license for the

    above mentioned patents, trademarks, copyrights, or other intellectual properties.

    For your convenience, Siemens may make this document available.

    The entire risk deriving from the use, or the results of the use, of this document are at users charge.

    The information contained in this document is subjected to changes without notice.

    Technical specifications and features are binding only insofar as they are specifically and expressly agreed previously in a written contract.

    Siemens gives no assurance relevant to the accuracy of the results or of the output deriving from such information.

    In case of utilization of the information transferred by means of this document, we advise You to verify if the export licenses, required by thelaws, have been granted or if there are not any other impediments arising from the laws in course in Italy, Germany or relevant to the export.

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    http://stile.pdf/http://stile.pdf/
  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    3/244

    STATUS OF MANUAL

    R-1SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006

    This OMN manual describes the procedures for the installation and the use of the

    software plug-in for the management of SRA4 SVR 4.6. equipment.

    With respect to the Issue 1, December 2005, the alarm tables in Chapter 6 and 7 have

    been updated.

    STATUS OF MANUAL

    Current: Issue 1, March 2006

    Previous: Issue 1, Dicember 2005

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    4/244

    STATUS OF MANUAL

    R-2SRA 4 - OMN

    911-381/02A0460 - Issue 1, March 2006

    BLAN

    KPAGE

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    5/244

    INDEX

    I-1SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006

    INDEX

    STATUS OF MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R.1

    INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I.1

    LIST OF ILLUSTRATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I.5

    LIST OF TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I.11

    1 GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1

    1.1 Subject and Purpose of the Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1

    1.2 Functionalities of the Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2

    1.3 Testing and Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4

    1.4 Responsibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4

    1.5 Conditions of the Provision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5

    1.6 Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5

    1.7 Lists of Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5

    2 EQUIPMENT MANAGEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1

    2.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.12.1.1 Local Craft Terminal (LCT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1

    2.2 User Classes and Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.22.2.1 User Classes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.22.2.2 Management of the access to the network element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3

    3 INSTALLATION OF PLUG-IN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1

    3.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1

    3.2 Installation Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1

    3.3 Uninstallation of Plug-In. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3

    4 COMMISSIONING VIA LCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1

    5 DOWNLOAD OF CONTROLLER UNIT SOFTWARE . . . . . . . . . . . . . . . . . . . . . . . . 5.1

    5.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1

    5.2 Download via FTP of IDU software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2

    5.3 Download via FTP of ODU software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    http://stile.pdf/http://stile.pdf/
  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    6/244

    INDEX

    I-2SRA 4 - OMN

    911-381/02A0460 - Issue 1, March 2006

    6 OPERATING GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1

    6.1 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1

    6.2 Architecture of the System with Double IDU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1

    6.3 Software Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.26.3.1 Plug-in Functionalities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.26.3.2 Hardware hardware key Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.36.3.2.1 Controller operating modalities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.46.3.2.2 Main/Expansion Configuration Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.56.3.2.2.1 IDU numbering in 2 IDU units based System Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.56.3.2.2.2 Main/Expansion negotiation at controller start up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.56.3.2.2.3 Loss and recovery of communication between main and expansion controllers . . . . . . . . . . . 6.56.3.2.2.4 Check of the HW and SW versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.56.3.3 License . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.66.3.4 Security. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.7

    6.4 Uploading of profile. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.8

    6.5 Push-buttons Key in Plug-in Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.9

    6.6 Structure of the Operating Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.9

    6.7 Configuration and Status of the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.106.7.1 Equipment Status & Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.116.7.1.1 System Configuration window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.176.7.1.1.1 Management of J0 byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.226.7.1.1.2 Config Type Setting window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.266.7.1.2 External Interface Setting window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.286.7.1.2.1 BB-Modem Payload window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.306.7.1.2.2 Q Interface Parameters window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.32

    6.7.1.2.3 Output Commands Settings window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.336.7.1.2.4 Input Station Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.346.7.1.2.5 AUX Channel BB-Modem window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.366.7.1.3 Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.386.7.1.3.1 Protection in (1+1) and 2x(1+1) System Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.396.7.1.3.2 Protection in (N+1) System Types (starting from SVR 4.4) . . . . . . . . . . . . . . . . . . . . . . . . . . 6.426.7.1.4 Co-Channel operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.456.7.1.5 Testing window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.486.7.1.5.1 Testing Mode & Loop-Backs window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.496.7.1.5.2 Recording of the Long Period Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.516.7.1.5.3 Timed Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.546.7.1.6 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.60

    6.7.1.7 Feature Control window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.616.7.1.8 Copy Config command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.626.7.1.9 Paste Config command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.636.7.1.10 BB-Modem Config window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.636.7.1.11 ATPC function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.656.7.1.11.1ATPC for ODU Narrowband. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.666.7.1.11.2ATPC for ODU Wideband . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.676.7.1.11.3Setting of the transmission power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.686.7.1.12 Configuration of ODU unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.696.7.1.12.1Configuration of Wideband ODU unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.696.7.1.12.2Configuration of Narrowband ODU unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.796.7.2 Software Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.826.7.2.1 IDU Software Banks window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.82

    6.7.2.2 ODU Software Banks window (only for ODU Wideband) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.846.7.2.3 FTP Transfer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.86

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    7/244

    INDEX

    I-3SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006

    6.7.2.4 SW Reset window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.876.7.3 Management of the network parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.876.7.3.1 Access to the dynamic routing table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.886.7.3.2 IP Address. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.89

    6.7.3.3 Interface network parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.916.7.3.4 Static Routing Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.956.7.4 Configuration of the error notification thresholds. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.976.7.5 Setting of date and time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.99

    6.8 Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1006.8.1 Physical and functional alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1006.8.1.1 TX Way Payload Functional Alarms window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1036.8.1.1.1 RST Tx STM-1 (BB-Modem) window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1046.8.1.2 RX Way Payload Functional Alarms window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1046.8.1.2.1 RST Rx STM-1 (BB-Modem) window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1066.8.1.3 IDU Other Functional Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1066.8.1.4 A.U. IDU User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.108

    6.8.1.5 Controller IDU User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1086.8.1.6 Mem Key User Physical Alarms window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1096.8.1.6.1 Mem Key Maint Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1096.8.1.7 FAN IDU User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1106.8.1.8 BB-Modem User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1106.8.1.9 i/f User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1116.8.1.10 System User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1126.8.1.11 ODU User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1136.8.1.11.1Physical Maintenance Alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1146.8.1.12 i/f CPU User Physical Alarms window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1156.8.1.13 i/f Exp Cable User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1156.8.1.13.1i/f Exp Cable Maint Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.116

    6.8.2 Alarm Thresholds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1166.8.3 Station alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.117

    6.9 Management of Measurements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1186.9.1 Unit Measurements window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1186.9.2 Measurement of RX and TX ODU power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.119

    6.10 Performance Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1206.10.1 RST Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1216.10.2 Unavailability Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1216.10.3 RSPI parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1226.10.4 RPS Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1236.10.5 Suspect Interval. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1246.10.6 Performance menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1256.10.7 Performance - PM Setting window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1266.10.8 Performance Monitoring View window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1296.10.8.1 RST Performance View: BB-Modem - Trib Side STM-1 (Quarter) window. . . . . . . . . . . . . . 6.1306.10.8.2 RST Performance View: BB-Modem - Trib Side STM-1 (Day) window. . . . . . . . . . . . . . . . . 6.1306.10.8.3 RST Performance View: RX Chain - Radio Side STM-1 (Quarter) window . . . . . . . . . . . . . 6.1316.10.8.4 RST Performance View: RX Chain - Radio Side STM-1 (Day) window . . . . . . . . . . . . . . . . 6.1326.10.8.5 RPS Performance View: RX Chain (Quarter) window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1326.10.8.6 RPS Performance View: RX Chain (Day) window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1336.10.8.7 RSPI Performance View: ODU Tx Side (Quarter) window . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1346.10.8.8 RSPI Performance View: ODU Rx Side (Quarter) window . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1346.10.8.9 RSPI Performance View: ODU (Day) window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.135

    6.11 Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1366.11.1 PID window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.138

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    8/244

    INDEX

    I-4SRA 4 - OMN

    911-381/02A0460 - Issue 1, March 2006

    6.11.2 Management of the user inventory data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1386.11.3 Equipment Software window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1396.11.4 About window (NetViewer/LCT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1396.11.5 Report. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.140

    6.12 Security. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.142

    6.13 NE Severity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1446.13.1 Critical. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1456.13.2 Major. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1496.13.3 Minor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1536.13.4 Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.154

    7 ALARM MANAGEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1

    7.1 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1

    7.2 Summary Alarm Signalings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1

    7.3 Alarm Signaling via Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1

    A LICENSE UPGRADE PROCEDURE FOR SRA4 EQUIPMENT . . . . . . . . . . . . . . . . . A.1

    A.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.1

    A.2 Upgrading Procedure Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.2

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    9/244

    I-5SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006

    LIST OF ILLUSTRATIONS

    LIST OF ILLUSTRATIONS

    Fig. 2.1 IDU unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2Fig. 3.1 Installation of plug-in (1/2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2Fig. 3.2 Installation of plug-in (2/2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2Fig. 5.1 Download procedure of IDU software via FTP (1/5). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2Fig. 5.2 Download procedure of IDU software via FTP (2/5). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3Fig. 5.3 Download procedure of IDU software via FTP (3/5). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3Fig. 5.4 Download procedure of IDU software via FTP (4/5). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4Fig. 5.5 Download procedure of IDU software via FTP (5/5). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4Fig. 5.6 IDU Software Banks window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5Fig. 5.7 Download procedure of ODU software via FTP (1/5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6Fig. 5.8 Download procedure of ODU software via FTP (2/5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.7

    Fig. 5.9 Download procedure of ODU software via FTP (3/5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.7Fig. 5.10 Download procedure of ODU software via FTP (4/5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.8Fig. 5.11 Download procedure of ODU software via FTP (5/5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.8Fig. 5.12 ODU Software Banks window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.9Fig. 6.1 Example of map with SRA4 equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.8Fig. 6.2 Operating menu of SRA 4 equipment plug-in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.10Fig. 6.3 Status and Config Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.11Fig. 6.4 Equipment Status & Configuration window (e.g.: 2x(1+1) FD DTI System Type) . . . . . . . . . . . . . 6.12Fig. 6.5 System Configuration window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.17Fig. 6.6 Configuration of System Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.18Fig. 6.7 Configuration of modulation and capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.19Fig. 6.8 Configuration of Radio Channel Destination. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.20Fig. 6.9 Configuration of Alarm unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.20

    Fig. 6.10 Configuration of Controller unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.20Fig. 6.11 Configuration of FAN unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.20Fig. 6.12 Configuration of BB-Modem unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.21Fig. 6.13 Configuration of ODU unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.21Fig. 6.14 Link ID (J0) BB-Modem1 window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.23Fig. 6.15 Configuration of TIM alarm activation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.23Fig. 6.16 Configuration of TIM alarm deactivation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.23Fig. 6.17 Window for the J0 Management Tributary Side (TX) selection . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.24Fig. 6.18 Window for enabling/disabling AIS Insertion for TIM (Tributary Side) . . . . . . . . . . . . . . . . . . . . . . 6.24Fig. 6.19 Window for the insertion of J0 Inserted Tributary Side. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.24Fig. 6.20 Window for the J0 Expected Tributary Side insertion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.25Fig. 6.21 Window for the J0 Management Radio Side (Rx) selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.25

    Fig. 6.22 Window for the AIS Insertion for TIM (Rx) enabling/disabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.25Fig. 6.23 Window for the J0 Inserted Radio Side insertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.26Fig. 6.24 Window for the J0 Expected Radio Side insertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.26Fig. 6.25 Config Type Setting window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.27Fig. 6.26 Configuration of Config Type Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.27Fig. 6.27 External Interface Setting window (System Type: 2x(1+1) FD DTI) . . . . . . . . . . . . . . . . . . . . . . . . 6.28Fig. 6.28 Configuration of Automatic Laser Shut Down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.29Fig. 6.29 Configuration of Masking STM-1 #2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.30Fig. 6.30 BB-Modem Payload window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.30Fig. 6.31 Configuration of Laser Restart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.31Fig. 6.32 Configuration of the Laser Forcing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.31Fig. 6.33 Q Interface Parameters window (write modality) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.32Fig. 6.34 Configuration of Bit-Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.33Fig. 6.35 Configuration of Electrical i/f Duplexing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.33

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    http://stile.pdf/http://stile.pdf/
  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    10/244

    I-6SRA 4 - OMN

    911-381/02A0460 - Issue 1, March 2006

    LIST OF ILLUSTRATIONS

    Fig. 6.36 Output Command Settings window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.33Fig. 6.37 Output Command description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.34Fig. 6.38 Enabling of Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.34Fig. 6.39 Station Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.34

    Fig. 6.40 Name/descripiton configuration window for station alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.35Fig. 6.41 Configuration of Polarity Alarm 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.35Fig. 6.42 AUX Channel BB-Modem window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.36Fig. 6.43 Configuration of Service Channel Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.36Fig. 6.44 Configuration of Enable 64 kb/s V11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.36Fig. 6.45 Configuration of Enable 64 kb/s G703. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.37Fig. 6.46 Configuration of Way Side (WS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.37Fig. 6.47 AUX Channel IDU #1 BB-Modem 1 window (example). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.37Fig. 6.48 Configuration of F1 byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.38Fig. 6.49 Configuration of Way Side (WS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.38Fig. 6.50 Protection Status & Configuration window (System Type 2x(1+1) FD DTI) . . . . . . . . . . . . . . . . . 6.39Fig. 6.51 Configuration of Switching Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.40

    Fig. 6.52 Configuration of Switch Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.40Fig. 6.53 Configuration of Trib Forcing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.41Fig. 6.54 Configuration of ODU Forcing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.41Fig. 6.55 Configuration of Dem Forcing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.41Fig. 6.56 Protection Status & Configuration window ((3+1) System Types). . . . . . . . . . . . . . . . . . . . . . . . . 6.42Fig. 6.57 Configuration of Switching Criteria Enabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.43Fig. 6.58 Configuration of Remote Tx Prioritary Ch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.43Fig. 6.59 Configuration of Switch Priority Ch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.44Fig. 6.60 Configuration of Switch Criteria Forcing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.44Fig. 6.61 Co-Channel window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.46Fig. 6.62 Configuration of synchronization modality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.47Fig. 6.63 Synch Forcing window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.47Fig. 6.64 Configuration of Synch Forcing (CC). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.47Fig. 6.65 Configuration of Polarization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.48Fig. 6.66 Testing window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.48Fig. 6.67 Testing Mode & Loop-Backs window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.49Fig. 6.68 Configuration of Loop-Back Trib Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.50Fig. 6.69 Configuration of Loop-Back Trib Side INT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.50Fig. 6.70 Configuration of Loop-Back Radio Side EXT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.50Fig. 6.71 Configuration of Modulator Mode BB-Modem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.51Fig. 6.72 Testing - Long PM Recording window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.51Fig. 6.73 Long period PM recording . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.52Fig. 6.74 Configuration of Recording Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.52Fig. 6.75 Configuration of recording start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.52Fig. 6.76 Enabling/disabling of the recording . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.53

    Fig. 6.77 Configuration of Timed Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.55Fig. 6.78 Single Timed Switching window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.56Fig. 6.79 Configuration of Switch Starting Position (example: ODU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.57Fig. 6.80 Example of Single Timed Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.57Fig. 6.81 Periodic Timed Switching window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.58Fig. 6.82 Example of Periodic switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.59Fig. 6.83 Maintenance window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.60Fig. 6.84 Feature Control window (write modality) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.61Fig. 6.85 Configuration of License Key #1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.61Fig. 6.86 BB-Modem Config window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.63Fig. 6.87 Configuration of Cable Length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.64Fig. 6.88 Configuration of IF Output Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.64

    Fig. 6.89 Configuration of TX Mod Spectrum Inversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.65Fig. 6.90 Configuration of XPIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.65

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    11/244

    I-7SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006

    LIST OF ILLUSTRATIONS

    Fig. 6.91 ODU Config window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.66Fig. 6.92 Hysteresis cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.66Fig. 6.93 Linear ATPC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.68Fig. 6.94 ODU Config window (Freq Mode = Continuous) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.69

    Fig. 6.95 ODU Config window (Freq Mode = Continuous) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.70Fig. 6.96 ODU Config window (Freq Plan Activation = On). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.70Fig. 6.97 Configuration of Freq Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.71Fig. 6.98 Frequency plan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.71Fig. 6.99 Enabling/disabling of Freq Plan Activation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.72Fig. 6.100 Configuration of Channel Spacing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.73Fig. 6.101 Configuration of TX Freq Ch#1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.73Fig. 6.102 Configuration of First Channel ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.73Fig. 6.103 Configuration of Last Channel ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.74Fig. 6.104 Configuration of RF Channel ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.74Fig. 6.105 Configuration of TX Freq . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.74Fig. 6.106 Configuration of RX Freq . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.74

    Fig. 6.107 Configuration of Pmin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.75Fig. 6.108 Configuration of ATPC Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.75Fig. 6.109 Configuration of ATPC Threshold. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.75Fig. 6.110 Configuration of ATPC Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.76Fig. 6.111 Configuration of Squelch SW Activation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.76Fig. 6.112 Configuration of Comp IF Cable Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.77Fig. 6.113 Configuration of the cable compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.77Fig. 6.114 Warning for temporary loss of the payload in transmission (Tx AGC) . . . . . . . . . . . . . . . . . . . . . . 6.78Fig. 6.115 Configuration of Tx AGC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.78Fig. 6.116 Warning for temporary loss of the payload in reception (IF Power RX) . . . . . . . . . . . . . . . . . . . . . 6.78Fig. 6.117 Configuration of IF Power (Rx) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.78Fig. 6.118 Configuration of IF Attenuation (Tx) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.79Fig. 6.119 ODU Config window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.79Fig. 6.120 Configuration of ATPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.80Fig. 6.121 Configuration of TX Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.80Fig. 6.122 Configuration of ATPC Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.80Fig. 6.123 Configuration of ATPC Threshold 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.81Fig. 6.124 Configuration of Nominal Power Level Setting Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.81Fig. 6.125 Configuration of Nominal Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.81Fig. 6.126 Software menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.82Fig. 6.127 IDU Software Banks window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.83Fig. 6.128 IDU Software Banks window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.83Fig. 6.129 ODU Software Banks window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.85Fig. 6.130 Warning for payload loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.85Fig. 6.131 Warning for not compatible SW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.86

    Fig. 6.132 Software Reset window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.87Fig. 6.133 Network menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.87Fig. 6.134 Directory tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.88Fig. 6.135 Structure of table.txt file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.88Fig. 6.136 Example of routing table seen by FTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.89Fig. 6.137 IP Address window (write modality) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.90Fig. 6.138 Configuration of IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.91Fig. 6.139 Configuration of Net Mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.91Fig. 6.140 NE Parameters window (with ETH MTU = default value). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.92Fig. 6.141 Configuration of ETH MTU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.93Fig. 6.142 NE Parameters window with ETH MTU field set to Other . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.93Fig. 6.143 Window for the insertion of an arbitrary value of ETH MTU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.93

    Fig. 6.144 Enabling/disabling of the Telnet port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.94Fig. 6.145 Configuration of RIPv1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.94

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    12/244

    I-8SRA 4 - OMN

    911-381/02A0460 - Issue 1, March 2006

    LIST OF ILLUSTRATIONS

    Fig. 6.146 Static Routing Table window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.96Fig. 6.147 Configuration of Destination Network Routing Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.96Fig. 6.148 Configuration of Subnet Mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.97Fig. 6.149 Configuration of Gateway Routing Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.97

    Fig. 6.150 Configuration of Metric. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.97Fig. 6.151 TCN - Threshold Settings window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.98Fig. 6.152 Configuration of B1 Threshold for SD alarm (tributary side) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.98Fig. 6.153 Configuration of B1 Threshold for SD alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.98Fig. 6.154 Date & Time window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.99Fig. 6.155 Alarms menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.100Fig. 6.156 Physical and Functional Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.101Fig. 6.157 TX Way Payload Functional Alarms window (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.103Fig. 6.158 RST Tx STM-1 (BB-Modem) window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.104Fig. 6.159 RX Way Payload Functional Alarms window (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.105Fig. 6.160 RST Rx STM-1 (BB-Modem) window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.106Fig. 6.161 IDU Other Functional Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.107

    Fig. 6.162 A.U. IDU User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.108Fig. 6.163 Controller IDU User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.108Fig. 6.164 Mem Key User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.109Fig. 6.165 Mem Key Maint Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.109Fig. 6.166 FAN IDU User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.110Fig. 6.167 BB-Modem User Physical Alarms window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.111Fig. 6.168 User Physical Alarms - IDU-ODU i/f window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.111Fig. 6.169 System User Physical Alarms window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.112Fig. 6.170 ODU User Physical Alarms window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.113Fig. 6.171 ODU Maint Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.114Fig. 6.172 ODU Maint Physical Alarms window - Wideband ODU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.114Fig. 6.173 i/f CPU User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.115Fig. 6.174 i/f Exp Cable User Physical Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.116Fig. 6.175 i/f Exp Cable Maint Physical Alarms window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.116Fig. 6.176 TCN - Alarm Threshold window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.117Fig. 6.177 Station Alarms window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.117Fig. 6.178 Measurements menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.118Fig. 6.179 Unit Measurements window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.118Fig. 6.180 Measurement - Record menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.120Fig. 6.181 Performance menu (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.125Fig. 6.182 Performance PM Setting window - Common Thresholds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.126Fig. 6.183 Performance PM Setting window - Independent Thresholds. . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.127Fig. 6.184 Configuration of RSPI Thresholds Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.128Fig. 6.185 Configuration of RLT ODU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.128Fig. 6.186 Configuration of TLT ODU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.128

    Fig. 6.187 Performance Monitoring View window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.129Fig. 6.188 RST Performance View: BB-Modem Trib Side (Quarter) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.130Fig. 6.189 RST Performance View: BB-Modem Trib Side (Day) window . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.131Fig. 6.190 RST Performance View: RX Chain - Radio Side STM-1 (Quarter) window. . . . . . . . . . . . . . . . . 6.131Fig. 6.191 RST Performance View: RX Chain - Radio Side STM-1 (Day) window . . . . . . . . . . . . . . . . . . . 6.132Fig. 6.192 RPS Performance View: RX Chain (Quarter) window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.133Fig. 6.193 RPS Performance View: RX Chain (Day) window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.133Fig. 6.194 RSPI Performance View: ODU - Tx Side (Quarter) window . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.134Fig. 6.195 RSPI Performance View: ODU - Rx Side (Quarter) window . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.135Fig. 6.196 RSPI Performance View: ODU (Day) window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.136Fig. 6.197 Inventory window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.137Fig. 6.198 PID window (e.g.: Controller). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.138

    Fig. 6.199 USER window (e.g.: Controller). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.138Fig. 6.200 User Inventory window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.139

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    13/244

    I-9SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006

    LIST OF ILLUSTRATIONS

    Fig. 6.201 Equipment Software window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.139Fig. 6.202 About NetViewer window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.140Fig. 6.203 About LCT window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.140Fig. 6.204 Security window (Admin user class) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.142

    Fig. 6.205 Window to enable the Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.142Fig. 6.206 Field Editing for the insertion of the new password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.143

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    14/244

    I-10SRA 4 - OMN

    911-381/02A0460 - Issue 1, March 2006

    LIST OF ILLUSTRATIONS

    BLAN

    KPAGE

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    15/244

    LIST OF TABLES

    I-11SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006

    LIST OF TABLES

    Tab. 6.1 Description of the push-buttons in the plug-in window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.9Tab. 6.2 Laser operating rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.31Tab. 6.3 Independent switches depending on System Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.54Tab. 6.4 ATPC management (ODU Narrowband) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.66Tab. 7.1 Functional Alarms: description and severity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.2Tab. 7.2 Physical Alarms: description and severity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.4Tab. A.1 License Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A.1

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    http://stile.pdf/http://stile.pdf/
  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    16/244

    LIST OF TABLES

    I-12SRA 4 - OMN

    911-381/02A0460 - Issue 1, March 2006

    BLAN

    KPAGE

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    17/244

    1 - GENERAL INFORMATION

    1-1SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006

    1 GENERAL INFORMATION

    1.1 Subject and Purpose of the Manual

    SRA4 is a STM-1 and 2xSTM-1 radio communication equipment for point-to-point

    applications, using an high frequency indoor-outdoor architecture, designed to transfer

    the SDH/SONET signals. SRA4 radio equipment is managed using the extended TNMP

    protocol; the network protocol is TCP/IP.

    SRA4 radio equipment is built up by:

    one or two indoor shelves (IDU, indoor unit), providing the base band;

    from one to four outdoor equipment (ODU, outdoor unit), containing RF devices.

    ODU units are connected with the IDU by means of an IF cable;

    one heater sub-unit on the outdoor equipment (optional).

    The IDU deals with all the digital interfaces and performs a first frequency conversion

    to/from IF signals which are transmitted to the ODU.

    The ODU performs signal amplification and frequency up/down conversion to/from the

    millimeter-wave frequency.

    The configuration of the indoor shelf and the ways controller card programs the slave

    cards are different according to the selected system type and configuration. In addition,

    system provisioning and management are available using local connection via standardRS-232 connection (F interface) or via 10 Base T Ethernet connection (Q interface).

    This OMN manual provides the necessary instructions for the management, via PC, of

    the SRA4 digital radio equipment with SVR 4.6. The management via software of the

    equipment with SVR 4.6 can be executed as by NetViewer 7.0 (management system of

    radio networks) as by LCT 6.1 (management system of the local terminal and/or of the

    radio link).

    For a detailed description of the units present in the system, refer to the UMN

    manual of SRA4 equipment.

    For the using modes of NetViewer/LCT, refer to the relevant operating guide.

    Without a written authorization, it is forbidden to forward to third parties the

    contents of the subject Manual.

    The Customer can require a copy of the subject manual pointing out its code

    (present on the cover rear-page).

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    18/244

    1 - GENERAL INFORMATION

    1-2SRA 4 - OMN

    911-381/02A0460 - Issue 1, March 2006

    1.2 Functionalities of the Equipment

    The equipment SVR 4.6 supports the following functionalities:

    Managed System Types:

    1+0 w/o MST

    1+1 Hot Stand-by w/o MST Single Tributary Interface

    1+1 Hetero frequency w/o MST Single Tributary Interface

    1+1 Hot Stand-by w/o MST Double Tributary Interface

    1+1 Hetero frequency w/o MST Double Tributary Interface

    2x(1+1) Frequency Diversity w/o MST Single Tributary Interface

    2x(1+1) Frequency Diversity w/o MST Double Tributary Interface

    2x(1+1) Hot Stand-by w/o MST Single Tributary Interface

    2x(1+1) Hot Stand-by w/o MST Double Tributary Interface

    2+0 w/o MST (with independent configuration of the two basebands)

    2+1 w/o MST 3+1 w/o MST

    Equipment traffic capacity

    Tributary capacity: STM-1 or 2xSTM-1

    Digital service channels: 2.048 Mbit/s (G.703) Way-Side

    Auxiliary Data Channels: 64 Kbit/s V.11 or 64 Kbit/s G.703

    Base-band interface:

    STM-1 electrical ITU-T G.703

    STM-1 optical ITU-T G.957 S-1.1

    Modulation type

    32 TCM + Reed-Solomon Concatenated Coding 128 TCM + Reed-Solomon Concatenated Coding

    Pattern type:

    AP (Alternate Polarization)

    CC (Co-Channel)

    ODU type

    Narrowband

    Wideband

    Available loop-back types

    Radio side up to tributary section

    Tributary side up to tributary physical interface

    Tributary side up to the modem interface

    1+1 protection

    RX radio side

    TX tributary side

    TX radio side

    Control of the transmission power

    ODU Narrowband. 2 ATPC levels (Pnom, Pnom-8). Range: 8 dBm

    ODU Wideband. Linearized for ODU Wideband

    Possibility of independent configuration of the BB-Modem units in the (2+0) System

    Type without MST

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    19/244

    1 - GENERAL INFORMATION

    1-3SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006

    Configuration of the operating parameters

    Transmission and reception frequency

    Transmission power (ATPC)

    Alarm parameters

    Remote controls

    Local loop-back (from LCT)

    User channels (byte F1/ byte S(2,3))

    ALS (Automatic Laser Shutdown)

    Laser restart

    Configuration of the co-channel operation

    Management of J0 byte

    Configuration of the error thresholds (TCN)

    Measures

    ODU transmitted power

    RF RX power

    Recordings

    Performance Monitoring (independent counters for each measurement point)

    Events

    Report of inventory data

    Alarms management

    Diagnostics

    Input of station alarms (max. 4)

    System alarms restitution (max. 8)

    Signalling of alarm threshold crossing

    Software download

    Local/remote download of the equipment software Switching of the Controller banks

    Copy of the active banks of the Controller

    Alignment of the unit software

    License management

    Management of the hardware key

    Management of the inventory data

    hardware data (unit PID data, user data)

    software data

    Support of the TNMP protocol (base and extended) as management application

    protocol

    Management system

    Local supervision of NEs and of the radio link via LCT

    Remote supervision of the NEs of the radio network via NetViewer

    Networking functions

    RIPv1 protocol for the transport of the routing information

    Propagation of static routing table

    Notification of the dynamic routing table

    Border Gateway

    Ingress Summarization

    Configuration of TCP/IP connection IP address

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    20/244

    1 - GENERAL INFORMATION

    1-4SRA 4 - OMN

    911-381/02A0460 - Issue 1, March 2006

    Static routing tables

    Net-mask

    configurable Ethernet MTU (Maximum Transfer Unit)

    Management interfaces F interface (RS-232) for the serial connection to LCT

    Q interface (10/100 Base T) for the connection to LAN network

    E interface (10 Base T) for the connection between the two IDUs in a system

    with double IDU

    Use of SOH bytes

    Byte S23 as auxiliary channel

    Byte S22 as ATPC channel

    Byte S32 as management channel (R)

    Management of Controller unit

    Selection of the active memory bank

    Software download from local PC or via remote

    Equipment commissioning (with recording of the relevant performance) and

    periodic tests

    Local History Log (storing of the last events occurred on the equipment)

    Switch of the synchronism source of the STM-1s for MS-AIS alarm (in case of

    2xSTM-1 capacity)

    Replacement of the alarm unit without traffic loss (only for the proper hardware

    version of the 2xSTM-1 unit).

    1.3 Testing and Warranty

    Refer to the contract clauses for the information about testing and warranty.

    1.4 Responsibility

    Refer to the contract clauses for the information about the subject matter.

    Besides it is necessary to observe that:

    the manufacturer declines all responsibilities deriving from the incorrect or wronguse of the equipment, from the utilization of unauthorized parts and circuit,

    component and system software violations.

    the responsibility for the application of safety rules and use prescriptions is

    entrusted to the technical personnel responsible for the various activities, which

    has to make sure that the authorized personnel is qualified to perform the

    requested activity and has the required knowledge.

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    21/244

    1 - GENERAL INFORMATION

    1-5SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006

    1.5 Conditions of the Provision

    The SRA4 plug-in is provided on CD-ROM and is included, together with the LCT

    program, into the equipment provision.The equipment CD-ROM includes:

    the LCT program for the management of the radio link and/or of the local radio

    equipment

    the SRA4 plug-in.

    The SRA4 plug-in can be included on demand into the CD-ROM of NetViewer.

    1.6 Related Manuals

    For the SRA4 equipment, the following manuals are available:

    User Manual (UMN)

    It contains the necessary informations for the equipment installation, the

    commissioning and the maintenance.

    Operating Manual (OMN)It contains the necessary informations for the equipment configuration and control

    by means of PC.

    LCT 6.1 (OMN)

    It contains the necessary informations for the configuration and control, by means

    of a service PC, of SRA4 link and of the relative equipments.

    NetViewer (OMN)

    It contains the necessary informations for the configuration and control, by means

    of a network PC, of SRA4 network and of each network equipments.

    All the manuals are available in English; they can be also provided in other languages,

    depending on the contract clauses.

    1.7 Lists of Abbreviations

    AGC

    Automatic Gain Control

    AIS

    Alarm Indication Signal

    ALS

    Automatic Laser Shutdown

    The plug-ins available on the CD-ROM of NetViewer depend on the provision

    conditions of NetViewer.

    By default, the plug-ins for Cisco router and generic SNMP device are always

    available.All the other plug-ins are provided only on demand.

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    22/244

    1 - GENERAL INFORMATION

    1-6SRA 4 - OMN

    911-381/02A0460 - Issue 1, March 2006

    ALM

    Alarm

    AP

    Alternate PatternATM

    Asynchronous Transport Mode

    ATPC

    Automatic Transmission Power Control

    AUX

    Auxiliary

    BB

    Base Band

    BBE

    Background Block Errors

    BER

    Bit Error Rate

    CC

    Co-Channel

    CH

    Channel

    CON

    Connected

    CPUCentral Processing Unit

    CRC

    Cyclic Redundancy Check

    Dem

    Demodulator

    DIS

    Disconnected

    DTI

    Double Tributary Interface

    EEPROM

    Electrically Erasable Programmable Read Only Memory

    EM

    Element Manager

    ES

    Errored Seconds

    ETSI

    European Telecommunications Standard Institute

    EW

    Early Warning

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    23/244

    1 - GENERAL INFORMATION

    1-7SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006

    FD

    Frequency Diversity

    FERF

    Far End Receive FailureFPGA

    Field Programmable Gate Array

    FSK

    Frequency Shift Keying

    FSRC

    Failed Switch Request Count

    FSRD

    Failed Switch Request Duration

    FTP

    File Trasfer Protocol

    Gnd

    Ground

    HBER

    High Bit Error Ratio

    HEX

    Hexadecimal

    HF

    Hetero Frequency

    HSBYHot Stand-by

    HW

    Hardware

    I/O

    Input/Output

    ID

    Identifier

    IDU

    InDoor Unit

    i/f

    Interface

    IF

    Intermediate Frequency

    IN

    Input

    IP

    Internet Protocol

    LCT

    Local Craft Terminal

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    24/244

    1 - GENERAL INFORMATION

    1-8SRA 4 - OMN

    911-381/02A0460 - Issue 1, March 2006

    LED

    Light Emission Diode

    LOF

    Loss Of FrameLOP

    Loss Of Pointer

    LOS

    Loss Of Signal

    MIB

    Management Information Base

    MIS

    Mismatch

    MOD

    Modulator

    MS

    Multiplex Section

    MSOH

    Multiplex Section OverHead

    MST

    Multiplex Section Termination

    NE

    Network Element

    ODUOutDoor Unit

    OI

    Outage Intensity

    OMN

    Operating Manual

    OnL

    On line

    OUT

    Output

    PC

    Personal Computer

    PID

    Product Identification Data

    PM

    Performance Monitoring

    PS

    Power Supply

    PSAC

    Protection Switch Actual Count

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    25/244

    1 - GENERAL INFORMATION

    1-9SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006

    PSAD

    Protection Switch Actual Duration

    PWR

    PowerRAM

    Random Access Memory

    RDI

    Remote Defect Indication

    RF

    Radio Frequency

    RFCOH

    Radio Frequency Customer OverHead

    RIP

    Routing Information Protocol

    RL

    Received Level

    RLTS

    Received Level Threshold Second

    RPS

    Radio Protection Switching

    RSOH

    Regenerator Section OverHead

    RSPIRegenerator Section Physical Interface

    RST

    Regenerator Section Termination

    RX

    Reception

    R/O

    Read Only

    R/W

    Read Write

    SCS

    Switching Control Signal

    SD

    Signal Degrade

    SDH

    Synchronous Digital Hierarchy

    SES

    Severely Errored Seconds

    SOH

    Section OverHead

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    26/244

    1 - GENERAL INFORMATION

    1-10SRA 4 - OMN

    911-381/02A0460 - Issue 1, March 2006

    SONET

    Synchronous Optical Network

    SPI

    SDH Physical InterfaceSRA

    Synchronous Radio Access

    S.T.

    System Type

    Stby

    Stand-by

    STI

    Single Tributary Interface

    STM

    Synchronous Transfer Module

    SVR

    Software Version Release

    SW

    Software

    TCM

    Trellis Code Modulation

    TCN

    Threshold Crossing Notification

    TCPTransmission Control Protocol

    TF

    Transmission Frequency

    TIM

    Trail Identifier Mismatch

    TL

    Transmitted Level

    TLTS

    Transmitted Level Threshold Second

    TMN

    Telecommunications Management Network

    TNMP

    Telecommunications Network Management Point

    TP

    Termination Point

    TRIB

    Tributary

    TX

    Transmission

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    27/244

    1 - GENERAL INFORMATION

    1-11SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006

    UAS

    UnAvailability Seconds

    UHF

    Ultra High FrequencyWS

    Way-Side

    XPIC

    Cross Polarity Interference Canceller

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    28/244

    1 - GENERAL INFORMATION

    1-12SRA 4 - OMN

    911-381/02A0460 - Issue 1, March 2006

    BLAN

    KPAGE

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    29/244

    2 - EQUIPMENT MANAGEMENT

    2-1SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006

    2 EQUIPMENT MANAGEMENT

    2.1 Introduction

    This manual describes the graphic user interface to manage the SRA4 equipment. The

    same graphic interface is specified for the LCT and the telecommunication network

    management.

    The configuration of a Network element (NE) can be managed either locally by the Local

    Terminal or remotely by the EM. The user interface of the EM is aware of the constrains

    related to the System Type and doesnt allow any illegal configuration. The NEController is aware of these constrains too and checks the configurations imposed either

    by the Local Terminal or by the EM.

    In order to avoid problems due to these duplicated checks, the remote configuration of

    a NE shall be managed according the following procedure:

    the EM shall write the right System Type value for the NE in the NE Controller;

    the NE Controller shall use this information to set the NE expected configuration to

    a default configuration containing all the mandatory units and to program the actual

    slave units to perform the functionalities implied by the System Type;

    the EM can then modify the configuration of the optional units and, if necessary,

    the type of the mandatory units.

    EM doesnt allow to remove a mandatory unit without a previous change in the System

    Type.

    2.1.1 Local Craft Terminal (LCT)

    LCT is a local personal computer which the operator uses to dialogue with the SRA4

    equipment. By means of LCT it is possible to modify and configure up to three SRA4 at

    the same time.

    It is used for the following activities:

    lining up,in order to start in service and check the equipment before its connection to the

    network;

    operation and maintenance,

    to allows the local access to the operator for the monitoring of the system and, at

    the same time, to modify the system configuration, if necessary. If the connection

    between the network manager and the SRA4 equipment is not possible (for

    hardware or software troubles), however LCT allows the system management.

    The connection between system and the local PC takes place by means of a RS-232

    V.24/V.28 interface. Its physical access is located on the main board in the IDU unit and

    allows a local access to the system. For the connection between LCT and SRA4

    equipment, a D-9 female connector is used to implement the RS-232 interface.

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    30/244

    2 - EQUIPMENT MANAGEMENT

    2-2SRA 4 - OMN

    911-381/02A0460 - Issue 1, March 2006

    To realize the connection via RS-232 to the SRA4 equipment, it is necessary to run from

    PC a direct connection with 38400 bps bit rate.

    By means of the local terminal, it is possible to set and modify the following parameters:

    NE address;

    the system type, stored in the EEPROM key;

    the type of the equipped units;

    the Modulator Mode;

    the loopbacks.

    Fig. 2.1 IDU unit

    2.2 User Classes and Security

    2.2.1 User Classes

    The user classes foreseen to access the system are the following ones:

    Anonymous (Security disabled) Admin User (administrator)

    Read Write User (read/write user)

    Read Only User (read only user)

    The user login class restricts the operations allowed to the user, as specified here below:

    read only users can only read, but not change, any system configuration;

    Q interface is used only by NetViewer management program.

    The Anonymous user class is present only for the access via LCT.

    Alarm unit hardware key FAN unit BB-Modem#1 unit

    Controller unit BB-Modem#2 unit

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    31/244

    2 - EQUIPMENT MANAGEMENT

    2-3SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006

    in addition to the previous class rights, read write users can also write the

    read/write the configuration parameters, but they cannot modify the password of

    any user class;

    in addition to the previous class rights, administrator users can also modify thepasswords for the administrator, normal and readonly user class.

    Before starting the operations with the NE, either the Local Terminal Operator or the EM

    Application must login to the NE, giving to the NE controller the user login class and the

    password for that class. Transmission of the protocol passwords is encrypted.

    The Local Terminal operator must enter the user login class at which he wants to

    operate and the relevant password. Therefore the identity of the local operator is

    unknown in the NE: the NE controller knows only the login class of the operator.

    2.2.2 Management of the access to the network element

    The concurrent access to the network element is achieved by allowing no more than one

    user with user login class Anonymous, Admin User, ReadWrite User can login to the NE

    at the same time. In this way, only one user at a time can modify the NE configuration.

    If an user attempts to log onto the NE with user login class Anonymous, Admin User,

    ReadWrite User while another user with writing rights is already logged, the log on is still

    accepted, but the rights of the new user are restricted to those of user login class Read

    Only.

    The NE controller will record an event whenever an user with user login class

    Anonymous, Admin User, ReadWrite User login or logout onto the NE. In order to

    change the user login class, an user must first disconnect and then reconnect during the

    login with the new user class.

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    32/244

    2 - EQUIPMENT MANAGEMENT

    2-4SRA 4 - OMN

    911-381/02A0460 - Issue 1, March 2006

    BLAN

    KPAGE

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    33/244

    3 - INSTALLATION OF PLUG-IN

    3-1SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006

    3 INSTALLATION OF PLUG-IN

    3.1 Overview

    The application program for the control and management of SRA4 equipment is a

    plug-in of the program for the management of SRA4 network/link.

    The NetViewer/LCT program is able to acknowledge and, then, manage only the radio

    equipments, whose plug-in has been previously installed.

    To install the plug-in software, the NetViewer/LCT program must be already installed;

    otherwise, first it is necessary to install the NetViewer/LCT program and, only after,install the plug-in software.

    The installation of plug-in software determines:

    the possibility for NetViewer/LCT program to manage SRA4 radio equipment;

    the addition of the help, relative to SRA4 management application, to the Help

    menu of NetViewer/LCT program.

    3.2 Installation Procedure

    The plug-in can be installed during the setup of NetViewer/LCT or added/replaced later;

    in this case, the procedure for the installation of the plug-in software related to SRA4

    equipment is the following one:

    Start the installation of the SRA4 plug-in (file ..\Disk1\setup.exe). If a plug-in

    version is already installed, the system requires a confirmation to continue with the

    installation and, then, continue and replace the already installed version.

    The Welcomewindow opens on the screen (Fig. 3.1).

    Click on Nextbutton to start the installation.

    At the end of installation, the Setup Completewindow (Fig. 3.2) opens. Click on

    Finishbutton to close and exit.

    For more informations about the NetViewer and LCT programs, refer to the related

    operating guide.

    If NetViewer/LCT is already running, it is necessary to exit from it.

    After the installation of the plug-in, it is necessary to restart NetViewer/LCT, if

    already running, to apply the changes.

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    34/244

    3 - INSTALLATION OF PLUG-IN

    3-2SRA 4 - OMN

    911-381/02A0460 - Issue 1, March 2006

    Fig. 3.1 Installation of plug-in (1/2)

    Fig. 3.2 Installation of plug-in (2/2)

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    35/244

    3 - INSTALLATION OF PLUG-IN

    3-3SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006

    3.3 Uninstallation of Plug-In

    For the uninstallation of the plug-in, no special procedure is required; then follow the

    typical uninstallation modality of a Microsoft Windows application (Add/RemoveProgramsin Control Panel).

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    36/244

    3 - INSTALLATION OF PLUG-IN

    3-4SRA 4 - OMN

    911-381/02A0460 - Issue 1, March 2006

    BLAN

    KPAGE

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    37/244

    4 - COMMISSIONING VIA LCT

    4-1SRA 4 - OMN911-381/02A0460 - Issue 1, March 2006

    4 COMMISSIONING VIA LCTThis Chapter lists all the configuration and activation operations which must be executed

    via LCT for the commissioning of the equipment.

    The sequence of the operations is decribed by means of a step-by-step procedure; for

    each operation, the heading of the table (upper cell on the right of the title) shows the

    paragraph of the operating guide which you have to refer to in order to get more details.

    Before starting the commissioning procedure, execute the following preliminary

    operations:

    Connect the LCT to the F interface of the equipment.

    Check that the hardware key is inserted before switching on the equipment.

    The IDU is provided with a hardware key, where the configuration of the equipment is

    stored to allow an easy and fast replacement of the Controller.

    The hardware key has the following characteristics:

    it is the key for the backup of the equipment configuration; each modification of a

    configuration parameter is stored in the non volatile memory of the Controller and

    immediately also in the non volatile memory of the hardware key (EEPROM) it is identified by:

    serial number, which is univocal

    the equipment type

    it is strictly associated, after the switching on, to the equipment controller (the

    Controller stores the serial number of the hardware key)

    it contains the licence; the hardware key provided with the equipment contains the

    licence ordered by the Customer.

    Also a maintenance key is available (Repair Key), to be used only in case of fault to the

    hardware key provided with the equipment. In the Repair Key there is stored only its own

    serial number.

    INTERFACE FOR THECONNECTION TO LCT

    HARDWARE KEY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

    FOR INTERNAL USE ONLY FOR INTERNAL USE ONLY

  • 7/27/2019 Siemens Sra4 Svr4.6 Omn - Operating Manual

    38/244

    4 - COMMISSIONING VIA LCT

    4-2SRA 4 - OMN

    911-381/02A0460 - Issue 1, March 2006

    Diagnostics of the hardware key

    For the diagnostics of the hardware key, the following diagnostic signalings via software

    are available:

    Key Missing or Key MismatchThis signaling is displayed in one of the two cases:

    the hardware key is disconnected. The controller detects, by means of a

    dedicated sensor, the availability of the memeory key. If the detection fails,

    the hardware key is disconnected

    the inserted key is not valid or it belongs to a different equipment.

    Key Fault

    The hardware key is fault or it is not accessible: the configurations stored in the non

    volatile memory of the controller are used.

    Statuses of the Controller

    The Controller of the equipment can assume one of the following operating statuses:

    No Setting Mode

    the external and internal interfaces are enabled; only reading operations are

    allowed. All the configuration settings are refused.

    Halt mode

    the controller does not execute any action. It refuses also the connection to LCT.

    To exit from this status, it is only possible to reset the controller or switch off the

    equipment (the correct hardware key must be inserted).

    Start-up of Controller

    The Controller executes the same actions made after a software reset, a bank switchingor a switching of the IDU unit. As soon as the embedded software exits from the boot

    phase, it controls the hardware key.

    if the hardware key is disconnected, the system enters in the status of Halt Mode

    if the hardware key is faulted, the system enters in the No Setting