Page 1: Seaside Heights NJSeaside Heights NJ Super Storm Sandy · Cummins Power Generation Based In Princeton NJ 2 Cummins Confidential. Cummins Power Systems •In business since 1937 •605

Seaside Heights NJSeaside Heights NJSuper Storm Sandy

Page 2: Seaside Heights NJSeaside Heights NJ Super Storm Sandy · Cummins Power Generation Based In Princeton NJ 2 Cummins Confidential. Cummins Power Systems •In business since 1937 •605

Your Presenter for this Case Study

Mike Dysart

Region General Manager - Eastern Region

Cummins Power Generation

Based In Princeton NJ

Cummins Confidential2

Page 3: Seaside Heights NJSeaside Heights NJ Super Storm Sandy · Cummins Power Generation Based In Princeton NJ 2 Cummins Confidential. Cummins Power Systems •In business since 1937 •605

Cummins Power Systems

•In business since 1937

•605 Employees

•110 Power Gen Techs

•Added 3 New Locations inAdded 3 New Locations in last 18 Months

Cummins Confidential3

Page 4: Seaside Heights NJSeaside Heights NJ Super Storm Sandy · Cummins Power Generation Based In Princeton NJ 2 Cummins Confidential. Cummins Power Systems •In business since 1937 •605

Seaside Heights•Jersey Shore Town on Barrier Island of New JerseyJersey Shore Town on Barrier Island of New Jersey

•Population – 3,000 •About 10 times that in Summer•53% employed is Service or Sales sector

•Economy based on summer business, hotels restaurants, houses to renty , ,

•Home of …

Cummins Confidential4

Page 5: Seaside Heights NJSeaside Heights NJ Super Storm Sandy · Cummins Power Generation Based In Princeton NJ 2 Cummins Confidential. Cummins Power Systems •In business since 1937 •605

The Project

Peak Shaving for Summer loads– 3 – 2000 KW, 12,470 Volts– 12,470 V Utility Paralleling Swgr– Sound Attenuated Enclosures– After treatment for Emissions

Sequence of Operations– Parallel (Peak Shave) with JP&L – the Power Company– Hot summer day, the Utility turns on our gens

Installed and Commissioned July 2012

Cummins Confidential5

Page 6: Seaside Heights NJSeaside Heights NJ Super Storm Sandy · Cummins Power Generation Based In Princeton NJ 2 Cummins Confidential. Cummins Power Systems •In business since 1937 •605

The Generator SetsEnclosures by ASI

Aftertreatment – Johnson/Matthey

QSK-60 – 2mw Diesel

Cummins Confidential6

Page 7: Seaside Heights NJSeaside Heights NJ Super Storm Sandy · Cummins Power Generation Based In Princeton NJ 2 Cummins Confidential. Cummins Power Systems •In business since 1937 •605

The Storm

Cummins Confidential7

Page 8: Seaside Heights NJSeaside Heights NJ Super Storm Sandy · Cummins Power Generation Based In Princeton NJ 2 Cummins Confidential. Cummins Power Systems •In business since 1937 •605

Aftermath –

Cummins Confidential8

Page 9: Seaside Heights NJSeaside Heights NJ Super Storm Sandy · Cummins Power Generation Based In Princeton NJ 2 Cummins Confidential. Cummins Power Systems •In business since 1937 •605

Cummins Confidential9

Page 10: Seaside Heights NJSeaside Heights NJ Super Storm Sandy · Cummins Power Generation Based In Princeton NJ 2 Cummins Confidential. Cummins Power Systems •In business since 1937 •605

Cummins Confidential10

Page 11: Seaside Heights NJSeaside Heights NJ Super Storm Sandy · Cummins Power Generation Based In Princeton NJ 2 Cummins Confidential. Cummins Power Systems •In business since 1937 •605

Cummins Power Systems Arrives Island was on lock down only essential people allowed in by Island was on lock down – only essential people allowed in by

the State Police– FEMA trailers for food and showers– Cold Hotels for shelter (Natural gas was gone)

Power Systems Technicians were some of the first to respond4 t h f C i P S t i l d– 4 techs from Cummins Power Systems involved

– Each Tech – covered a 5 day shift

– Ran the Gens for 20 days straighty g– 1000 gal of fuel per day – truck every day– PM after the 1st 10 days – then went to 2nd gen

Sequence of Ops – Changed on site by Power Systems– PCC-3201 Peak Shaving to Isolated Bus – our controls allow this

change quite easilyg q y

Cummins Confidential11

Page 12: Seaside Heights NJSeaside Heights NJ Super Storm Sandy · Cummins Power Generation Based In Princeton NJ 2 Cummins Confidential. Cummins Power Systems •In business since 1937 •605

Other Duties for CPS

450 Customers via phone 260 Actual site visits 25 involved Life Saftey type loads Flooded Newark BranchFlooded Newark Branch

Cummins Confidential12

Page 13: Seaside Heights NJSeaside Heights NJ Super Storm Sandy · Cummins Power Generation Based In Princeton NJ 2 Cummins Confidential. Cummins Power Systems •In business since 1937 •605

On site CPS techs – not only Seaside

Sidera Networks Saus DataMorgan Stanley Bank of AmericaBank of America Digital Realty Huntington Life Sciences (Biotech) Huntington Life Sciences (Biotech) Quality Technical

Cummins Confidential13

Page 14: Seaside Heights NJSeaside Heights NJ Super Storm Sandy · Cummins Power Generation Based In Princeton NJ 2 Cummins Confidential. Cummins Power Systems •In business since 1937 •605

Thank You

Cummins Confidential14