www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2012 Cooper Crouse-Hinds1162
10L
CCH UX Series LED Exit Signs
UL ListedAvailable with Cl. I, Div. 2,Groups A, B, C, D rating
NEMA 4X, IP6610L
The Cooper Crouse-Hinds CCH UX Series LED Exit Sign combinesthe strength and durability of die cast aluminum with architecturally-pleasing aesthetics. The CCH UX Series is illuminated by LEDs,providing the customer with a long-life, low maintenance,dependable exit sign for use in conditions where reliability is crucial.
Designed for the most severe environments, the CCH UX Series willprovide maximum performance against rain, moisture, cold,corrosion, and dust in applications such as manufacturing plants,refineries, petrochemical and chemical plants, waste and sewagetreatment facilities, food processing, and other industrial facilities.
Applications: In locations deemed hazardous due to the presence of flammable
vapors or gases In areas where the presence of gases or vapors may become
present during an abnormal, unusual, or accidental conditions Outdoor and wet applications Where required by the National Electrical Code, Life Safety
Code, or other applicable codes
Benefits of LED Technology: Provides safe and reliable exit marking both indoors and outdoors
during power failure or interruption of power to normal lightingsystem
Long life (>50K hours) for years of maintenance-free operation Energy-efficient for lower cost of operation Low temperature operation with no loss of illumination Rugged and durable light source for the harshest of environments
Certifications and Compliances: NEMA 4X, UL50 UL924 wet location IP65, IP66 Available with NEC hazardous location rating
- UL844 Class I, Division 2, Groups A, B, C, D
Temperature Performance Data:CCH UX Series Exit Sign: -45C (-49F) to 45C (113F)CCH UX-HAZ Hazardous Location Exit Sign: T6 rating at 45C (113F)
Ordering Information:Catalog Number Housing Finish Letter Color
CCH UX70RSDHAZ Silver Housing Red LEDCCH UX60RHAZ Silver Housing Red LEDCCH UX70GSDHAZ Silver Housing Green LEDCCH UX60GHAZ Silver Housing Green LEDCCH UX70RSD Silver Housing Red LEDCCH UX70RWHSD White Housing Red LEDCCH UX70RBKSD Black Housing Red LEDCCH UX60R Silver Housing Red LEDCCH UX60RWH White Housing Red LEDCCH UX60RBK Black Housing Red LEDCCH UX70GSD Silver Housing Green LEDCCH UX70GWHSD White Housing Green LEDCCH UX70GBKSD Black Housing Green LEDCCH UX60G Silver Housing Green LEDCCH UX60GWH White Housing Green LEDCCH UX60GBK Black Housing Green LED
Electrical Ratings: Power Supply
120V/277V dual voltage LED Exits - Red
Input Power120V = 2.7W277V = 3.2W
Input Current:(Max.)120V = .07A277V = .04A
LED Exits - GreenInput Power120V = 2.3W277V = 3.0W
Input Current:(Max.)120V = .08A277V = .03A
DimensionsIn Inches:
Features and Benefits: Wet location, outdoor rated for use in the most demanding
environments Optional hazardous location rating available Dual voltage 120V/277V reduces wiring errors Heavy-duty nickel cadmium battery for long life 24-hour charge and recharge recovery time increases safety Heavy-duty injection molded polycarbonate lens protects against
impact and corrosion Brown-out protection protects battery and reduces labor Heavy-duty aluminum die cast housing protects against impact
and chemical resistance LEDs provide long life, even illumination, and energy savings Wide operating temperature range (-45C to 45C) Self-diagnostic testing reduces costs by eliminating scheduled
equipment verification tests Heavy duty nickel cadmium battery for long life meets 90 minute
requirements for battery operated emergency system
Mounting: wall mount, ceiling mount, end mountConduit Entry: top, bottom, or either side of the unit
-
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds 1155
10L10LCPMVFB Emergency
Compact FluorescentContinuous OperationChamp-Pak Luminaires
Cl. I, Div. 2, Groups A, B, C, DRestricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826)Certified for IEC Zone 2 (Suffix S826TB)
Cl. II, Groups E, F, G; Cl. III &Simultaneous Presence*Marine & Wet Locations3, 3R, 4, 4X; IP66Emergency Lighting
Applications: Where emergency lighting is required to
permit workers in industrial areas tosafely encounter their surroundingsduring power failures
Where emergency egress lighting isrequired, such as: catwalks, walkways,tunnels, doorways, stairs, stairwells,ramps and aisles
Indoor and outdoor wall mounting orvertical surface mounting where minimalluminaire depth is required in: Manufacturing plants and heavyindustrial facilities Industrial process facilities such asrefineries, chemical, petrochemical,pharmaceutical, and platforms Waste or sewage treatment plants Offshore, dockside, and harborinstallations
For security and safety lighting inindustrial facilites for lighting of loadingdocks, tunnels, and stairways
For marine, wet location, hose down,and corrosive environments
Features and Benefits: Unique compact shallow profile design
mounts virtually anywhere Side hinged cover with two screw
closing for easy installation andmaintenance
Gray Corro-free epoxy powder coattwo-piece housing provides superiorcorrosion resistance
Unique stainless steel wire guardaccessory attaches without anyadditional hardware for easy installationand maintenance
Glass refractor provides uniform lightdistribution to eliminate glare
Silicon gaskets make luminaire suitablefor NEMA 4X, marine enviroments
High power factor ballasts (+90%) arestandard, which allow more luminairesper circuit
Standard Materials: Luminaire housing and door frame
assembly copper-free aluminum External hardware stainless steel Lens heat- and impact-resistant
refractor style glass Gaskets silicon rubber Reflector aluminum light sheet Wire guard stainless steel
Standard Finishes: Aluminum Corro-free epoxy powder coat Stainless steel natural
Certifications andCompliances: NEC/CEC:
Class I, Division 2, Groups A, B, C, DClass II, Class III & SimultaneousPresence(Class I, Division 2 and Class II)Class I, Zone 2
IEC:Zone 2 Ex nR IIC
UL Standards:844, 2279 Hazardous (Classified)Locations1598 Luminaires1598A Marine Locations
CSA Standards:C22.2 No. 137
IEC Standards:60079-15
About the Battery: Bodine fluorescent battery pack ballasts are UL component recognized Sealed, maintenance-free, high temperature nickel cadmium Solid state chargers are sealed inside the ballast case 90 minute illumination time 10-year life expectancy 2-year full warranty During auxiliary use 1 lamp has continuous operation A red indicator light indicates the battery is charging Wiring instructions for a "Push-to-Test" button is supplied with the fixture
Electrical Rating Ranges: 52 watts 120277V, 5060 Hz 120V, 60 Hz 347V, 60 Hz
Options:Description SuffixRestricted breathing construction................................................................................. S826
Class I, Division 2 & Zone 2 suitabilityCooler operating temperatures (T-numbers)
Certified for IEC Zone 2 (Suffix S826TB)....................................................................... S826TBFurnished with:Terminal BlockCrimp TerminalsDedicated voltage ballasts (no MT, DT or TT)
Factory assembled with lamp installed......................................................................... FAFused - projects ballast and capacitors against abnormal line conditions.................. S658
(Not for use in Canada)(Not for Marine use)
Accessories:Description Cat. #Stainless steel wire guard............................................................................................. P55
*Consult Cooper Crouse-Hinds.
1154-1155.qxp 5/30/2011 11:16 AM Page 1155
-
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds1156
10L
10L CPMVFB EmergencyCompact FluorescentContinuous OperationChamp-Pak Luminaires
Ordering InformationDimensions & Weights
Ordering Information:
Hub SizeLampWatts
Cat. # for usewith ANSI Lamps
3/4 NPT 26 CPMVFB2W026
DimensionsIn Inches:
Net Weights:Luminaire Less Guard 18.6 lbs.P55 Guard 0.5 lbs.
Standard Voltage BallastsNEC/UL CEC/CSA (cUL)
Voltage 120277V 5060 Hz 120V/60 Hz 347V 60 HzSuffix /UNV /120CAN /347
1156-1157.qxp 5/30/2011 11:16 AM Page 1156
-
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds 1149
10L10LDMVF(B) Exit Sign
Fluorescent LuminaireCl. I, Div. 2; Groups A, B, C, DRestricted Breathing Cl. I,Div. 2 & Zone 2 (Suffix S826)Certified for IEC Zone 2 (Suffix S826TB)
Cl. II, Groups E, F, G,Cl. III & Simultaneous PresenceMarine & Wet Locations3, 3R, 4X; IP66
About the Battery: Bodine fluorescent battery pack ballasts
are UL component recognized Sealed, maintenance-free, high
temperature nickel cadmium Solid state chargers are sealed inside the
ballast case 90 minute illumination time 10-year life expectancy 2-year full warranty During emergency use 1 lamp has
continuous operation A red indicator light indicates the battery
is charging Wiring instructions for a "Push-to-Test"
button is supplied with the fixture
Energy Savings: Less wattage used with compact
fluorescent lamps compared toequivalent incandescent lamps providingthe same light output
Standard Materials: Ballast housings and mountings copper-
free aluminum (less than 0.4 of 1%) Exterior hardware stainless steel Globe heat- and impact-resistant
internally fluted glass
Standard Finishes: Aluminum gray epoxy powder coat Krydon material high reflectance white Stainless steel natural
Electrical Rating Ranges: 52 Watt 120277V, 5060 Hz 120V, 60 Hz 347V, 60 Hz
Options:Description Suffix Lamps supplied with exit sign............................................... S714Top hat with stainless steel threaded insert.......................... S806Restricted breathing construction.......................................... S826
Class I, Division 2 & Zone 2 suitabilityCooler operating temperatures (T-Numbers)
Certified for IEC Zone 2......................................................... S826TBFurnished with:Terminal BlockCrimp TerminalsDedicated voltage ballasts (no MT, DT or TT)
Certifications andCompliances: NEC and CEC:
Class I, Division 2, Groups A, B, C, DClass II, Class III & SimultaneousPresence(Class I, Division 2 and Class II)Class I, Zone 2
IEC:Zone 2 Ex nR IIC
UL Standards:844, 2279 Hazardous (Classified)Locations1598 Luminaires1598A Marine Luminaires
CSA Standards:C22.2 No. 137
IEC Standards:60079-15
MountingType
SupplyVoltageVolts/Hertz Fluorescent Cat. #
Fluorescent withBattery Back-up Cat. #
Pendant120277V / 5060 Hz DMVF2A052G/UNV EXD DMVFB2A052G/UNV EXD120V / 60 Hz (Canada) DMVFB2A052G/120CAN EXD347V / 60 Hz DMVF2A052G/347 EXD DMVFB2A052G/347 EXD
Ceiling120277V / 5060 Hz DMVF2C052G/UNV EXD DMVFB2C052G/UNV EXD120V / 60 Hz (Canada) DMVFB2C052G/120CAN EXD347V / 60 Hz DMVF2C052G/347 EXD DMVFB2C052G/347 EXD
Wall120277V / 5060 Hz DMVF2TW052G/UNV EXD DMVFB2TW052G/UNV EXD120V / 60 Hz (Canada) DMVFB2TW052G/120CAN EXD347V / 60 Hz DMVF2TW052G/347 EXD DMVFB2TW052G/347 EXD
Ordering Information:
Applications:DMVF(B) Exit Signs are used: In any building or enclosed area where
people work Where illuminated exit signs are required To provide distinct, highly visible exit
markings To indicate the direction of travel to exits In locations deemed hazardous due to
the presence of flammable vapors orgases, or combustible dusts
Features: Six inch letters on white glass sign panel
make the word "exit" stand out boldlyand clearly
Housings made of die-cast copper-freealuminum (less than 0.4 of 1% copper)for strength and resistance to corrosion
Mounting module equipped with integralhub set-screws for vibration resistance(ceiling and pendant mounts)
Hubs are provided with an integralconduit stop and bushing to help preventdamage to field wiring during installation
Epoxy powder finish and stainless steelexternal hardware for resistance tocorrosion
Long life gaskets which provide sealsbetween mounting module, housing, andglobe assembly
Grounding wire for safety Cool operating design Optional emergency battery back-up
operation during power outage
1148-1149.qxp 5/30/2011 11:14 AM Page 1149
-
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds 1157
10LDMVFB EmergencyCompact FluorescentContinuous OperationChamp Luminaires
Cl. I, Div. 2, Groups A, B, C, DRestricted Breathing Cl. I,Div. 2 & Zone 2 (Suffix S826)Certified for IEC Zone 2 (Suffix S826TB)
Cl. II, Groups E, F, G; Cl. III &Simultaneous PresenceMarine & Wet Locations3, 3R, 4, 4X; IP66Emergency Lighting
Applications:DMVF Series Champ Lighting Luminairesare used: Where emergency lighting is required to
permit workers in industrial areas tosafely encounter their surroundingsduring power failures
Where emergency egress lighting isrequired, such as: catwalks, walkways,tunnels, doorways, stairs, stairwells,ramps, and aisles
In areas made hazardous by abnormalconditions resulting in the presence offlammable vapors or gases
In areas made hazardous by thepresence of combustible dusts
Where combustible dusts and flammablevapors are present simultaneously
In marine applications where water sprayand corrosive atmospheres areconsiderations
On installations where vibration andrough usage are problematic
Where a cool, efficient light source is required
In areas that require lamps to reach fullillumination immediately
In refineries, chemical and petrochemicalfacilities, grain processing, handling orstorage facilities, manufacturing plants,wastewater treatment plants, sewagetreatment plants, oil terminals, foodprocessing facilities, breweries, and any other manufacturing or processingfacility where safe, reliable hazardousarea fluorescent or auxiliary lighting is needed
Standard Features: Housings made of die-cast copper-free
aluminum (less than 0.4 of 1% copper)for strength and resistance to corrosion
Mounting modules equipped withintegral hub set-screws for vibrationresistance (ceiling, pendant, and quadmounts)
Hubs are provided with an integralconduit stop and bushing to help preventdamage to field wiring during installation
Epoxy powder finish and stainless steelexternal hardware for resistance tocorrosion
Long-life gaskets which provide sealsbetween mounting module, housing,and optical assembly
Grounding wire for safety Cool operating design Optional stainless steel open bottom
guard permits direct access to the globefor easy relamping
Battery pack ballast for emergencylighting
Energy Savings Less wattage used with compact
fluorescent lamps compared toequivalent incandescent lampsproviding the same light output
About the Battery (DMVFB Units): Bodine fluorescent battery pack ballasts
are UL component recognized Sealed, maintenance-free, high
temperature nickel cadmium Solid state chargers are sealed inside
the ballast case 90 minute illumination time 10-year life expectancy 2-year full warranty During auxiliary use 1 lamp has
continuous operation A red indicator light indicates the battery
is charging Wiring instructions for a "Push-to-Test"
button is supplied with the fixture
Standard Materials: Ballast housings and mountings copper-
free aluminum (less than 0.4 of 1%) External hardware guards stainless steel Reflectors Krydon fiberglass-
reinforced polyester material Globe heat- and impact-resistant
internally fluted glass
Standard Finishes: Aluminum gray epoxy powder coat Krydon material high reflectance white Stainless steel natural
Electrical Rating Ranges: 52, 64, and 84 watts 120277V, 5060 Hz 347V, 60 Hz
Certifications andCompliances: NEC/CEC:
Class I, Division 2, Groups A, B, C, DClass II, Class III & Simultaneous Presence (Class I,Division 2 and Class II)Class I, Zone 2Emergency Lighting
IEC:Zone 2 Ex nR IIC
UL Standards:844, 2279 Hazardous (Classified)Locations1598 Luminaires1598A Marine Locations924 Emergency Lighting
CSA Standards:C22.2 No. 137
IEC Standards:60079-15
Options:Description Suffix Restricted breathing
construction................................ S826-Class I, Division 2 & Zone 2 suitability-Cooler operating temperatures(T-numbers)
Certified for IEC Zone 2............. S826TB-Furnished with:Terminal BlockCrimp Terminals
Emergency operation only Consult Cooper-Hinds
Factory assembled with lampinstalled....................................... FA
Fused to protect ballastagainst abnormal line conditions(not for use in Canada) (not formarine use).................................. S658
Lamps supplied with luminaire... S714 Top hat with stainless steel
threaded insert to attach ballasthousing........................................ S806
TEFLON coating on globe forincreased shatter protection....... S808
Accessories:(Order separately)Description Cat. #
Dome RD73930 Angle RA739
10L
1156-1157.qxp 5/30/2011 11:16 AM Page 1157
-
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds1158
10L
10L
MountingStyle
HubSize (In.)
LampWatts
DMVFB SeriesFluorescent with BatteryBack-Up with G303 Globeand P33 GuardCat. #
Pendant Mount 3/4 52 DMVFB2A052GP1 DMVFB3A052GP3/4 64 DMVFB2A064GP1 DMVFB3A064GP3/4 84 DMVFB2A084GP1 DMVFB3A084GP
Flexible PendantMount
3/4 52 DMVFB2HA052GP3/4 64 DMVFB2HA064GP3/4 84 DMVFB2HA084GP
Ceiling MountThru-Feed
3/4 52 DMVFB2C052GP1 DMVFB3C052GP3/4 64 DMVFB2C064GP1 DMVFB3C064GP3/4 84 DMVFB2C084GP1 DMVFB3C084GP
Wall MountThru-Feed
3/4 52 DMVFB2TW052GP1 DMVFB3TW052GP3/4 64 DMVFB2TW064GP1 DMVFB3TW064GP3/4 84 DMVFB2TW084GP1 DMVFB3TW084GP
Quad-Mount 3/4 52 DMVFB25Q052GPPendant, AdjustableThru-Feed, 25 Angle,121/2 Angle
3/4 64 DMVFB25Q064GP3/4 84 DMVFB25Q084GP
Stanchion Mount 11/2 52 DMVFBJ052GP25 Angle 11/2 64 DMVFBJ064GP
11/2 84 DMVFBJ084GP
Stanchion Mount 11/2 52 DMVFBP052GPStraight 11/2 64 DMVFBP064GP
11/2 84 DMVFBP084GP
1. Catalog numbers are basic numbers. Voltage must be specified.
Standard Voltage Ballasts
NEC/UL CEC/CSA (cUL)
1. Voltage 120277V 5060 Hz 120V/60 Hz 347V 60 HzSuffix /UNV /120CAN /347
Note: For technical information on familytrees, temperature performance data,dimensions, weights, and photometrics,refer to Series in Section 6L.
DMVFB EmergencyCompact FluorescentContinuous OperationChamp Luminaires
Cl. I, Div. 2, Groups A, B, C, DRestricted Breathing Cl. I,Div. 2 & Zone 2 (Suffix S826)Certified for IEC Zone 2 (Suffix S826TB)
Cl. II, Groups E, F, G; Cl. III &Simultaneous PresenceMarine & Wet Locations3, 3R, 4, 4X; IP66Emergency Lighting
1158-1159.qxp 5/30/2011 11:17 AM Page 1158
-
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds1148
10L
EVLPF(B) Exit SignFluorescent Luminaire
Cl. I, Div. 1, Groups B (suffix GB), C, DCl. I, Zone 1, Groups IIB + H2(GB suffix), IIBCl. II, Div. 1, Groups E, F, G; Class III,Simultaneous Presence
Marine & WetLocations3, 3R, 4, 4X;IP66
Applications:EVLPF(B)-EXD Exit Signs are used: In any building or enclosed area where
people work where illuminated exitsigns are required
To provide distinct, highly visible exitmarking
To indicate the direction of travel to exits In locations deemed hazardous due to
the presence of flammable vapors,gases, or combustible dusts
Features and Benefits: Six inch red letters on white glass sign
panel make the word "EXIT" stand outboldly and clearly
Lightweight copper-free aluminumhousing with powdered epoxy finish
All exterior hardware is corrosion-resistant stainless steel
Three mounting arrangements: pendant,ceiling, and wall bracket
Integral ballast High power factor (90%+) ballasts Easier assembly, installation, and
maintenance Outdoor, hose down, marine and
corrosive environments suitable Ideal for adverse environments typical of
industrial facilities Ground wire for safety Optional battery back-up for operation
during power outage
About the Battery: Bodine fluorescent battery pack ballasts
are UL component recognized Sealed, maintenance-free, high
temperature nickel cadmium Solid state chargers are sealed inside
the ballast case 90 minute illumination time 10-year life expectancy 2-year full warranty During emergency use 1 lamp has
continuous operation Red indicator light indicates the battery
is charging Wiring instructions for a "Push-to-Test"
button is supplied with the luminaire
Standard Materials: Mounting modules, cover, ballast
housing, globe holder copper-freealuminum
Globe heat- and impact-resistant glass Exterior hardware stainless steel
Standard Finishes: Copper-free aluminum Corro-free
powdered epoxy
Ratings (Electrical/Size):Sources/wattage: 52W (2-26W lamps) 120-277V, 50-60 Hz 120V, 60 Hz 347V, 60 HzConduit entries: 3/4", 1" NPT pendant, wall bracket,
ceiling
Certifications andCompliances: NEC and CEC:
Class I, Division 1, Groups B (GBsuffix), C, DClass I, Zone 1, Groups IIB + H2 (GBSuffix), IIB, IIAClass II, Class III & SimultaneousPresence (Class I and Class II)
UL Standards:844 Hazardous (Classified) Locations1598 Luminaires1598A Marine Locations
CSA Standards:C22.2 No. 137
Options:Description Suffix Group B suitability GBFactory assembled with lamps FA
10L
Energy Savings: Less wattage used with compact
fluorescent lamps compared toequivalent incandescent lamps providingthe same light output
Ordering Information:
MountingType
SupplyVoltageVolts/Hertz Fluorescent Cat. #
Fluorescent withBattery Back-up Cat. #
Pendant120277V / 5060 Hz EVLPFA02520/UNV EXD EVLPFBA02520/UNV EXD120V / 60 Hz (Canada) EVLPFBA02520/120CAN EXD347V / 60 Hz EVLPFA02520/347 EXD EVLPFBA02520/347 EXD
Ceiling120277V / 5060 Hz EVLPFCX02520/UNV EXD EVLPFBCX02520/UNV EXD120V / 60 Hz (Canada) EVLPFBCX02520/120CAN EXD347V / 60 Hz EVLPFCX02520/347 EXD EVLPFBCX02520/347 EXD
Wall120277V / 5060 Hz EVLPFBX02520/UNV EXD EVLPFBBX02520/UNV EXD120V / 60 Hz (Canada) EVLPFBBX02520/120CAN EXD347V / 60 Hz EVLPFBX02520/347 EXD EVLPFBBX02520/347 EXD
1148-1149.qxp 5/30/2011 11:14 AM Page 1148
-
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds 1159
10LEVLPFB EmergencyCompact FluorescentContinuous OperationLow Profile Luminaires
Cl. I, Div. 1, Groups B (GB Suffix), C, DCl. I, Zone 1, Groups IIB + H2(GB suffix), IIB, IIACl. II, Div. 1, Groups E, F, G; Class III,Simultaneous Presence
Marine & WetLocations3, 3R, 4, 4X; IP66Emergency Lighting
Applications:Cooper Crouse-Hinds Low ProfileHazardGard Luminaires are used in: Areas that require lamps to reach full
lumination immediately Where emergency lighting is required to
permit workers in industrial areas tosafely encounter their surroundingsduring power failures
Where emergency lighting is requiredsuch as: catwalks, walkways, tunnels,doorways, stairs, stairwells, ramps, andaisles
Areas where flammable or explosivevapors or gases are present
Hazardous areas, both indoors andoutdoors, where long life and lowmaintenance costs are desired
Petroleum refineries, chemical,petrochemical and pharmaceuticalplants, oil terminals, gas plants andother heavy process industry facilities
Waste treatment facilities Drilling platforms and other coastal and
offshore hazardous areas
Features and Benefits: Small, compact size Two start Acme threaded construction Easier assembly, installation, and
maintenance Lightweight copper-free aluminum
housing with powdered epoxy finish All exterior hardware is corrosion-
resistant stainless steel Four mounting arrangements: pendant,
ceiling, wall bracket, and stanchion Integral ballast High power factor (90%+) ballasts Uses same mounting modules as the
standard HazardGard Internally fluted glass globes Krydon construction dome and angle
reflectors won't rust, corrode, dent,chip, or peel
Now available in components luminairebody, mounting module, guard,reflectors
Three wire construction For energy conservation, luminaires can
be switched off without affecting theemergency operation feature
Standard Materials: Mounting modules, cover, ballast
housing, globe holder copper-freealuminum
Globe heat- and impact-resistant glass Exterior hardware stainless steel Reflectors (dome & angle) Krydon
fiberglass-reinforced polyester
Standard Finishes: Copper-free aluminum Corro-free
powdered epoxy Krydon white Stainless steel guard
Energy Savings Less wattage used with compact
fluorescent lamps compared toequivalent incandescent lamps providingthe same light output
Ratings (Electrical/Size):Sources/Wattage: Fluorescent continuous operation
emergency lighting 52W (2-26W lamps)and 64W (2-32W lamps) compactfluorescent voltages
Fluorescent emergency lighting120277V, 5060 Hz120V, 60 Hz347V 60Hz
Conduit entries: 3/4", 1" NPT pendant, wall bracket,
ceiling 11/4" NPT stanchion
Certifications andCompliances: NEC/CEC:
Class I, Division 1, Groups B (with GB suffix), C, DClass I, Zone 1, Groups IIB + H2(GB Suffix), IIB, IIAClass II, Class III & SimultaneousPresence(Class I and Class II)Emergency Lighting
UL Standards:844 Hazardous (Classified) Locations1598 Luminaires1598A Marine Locations924 Emergency Lighting
CSA Standards:C22.2 No. 137
Options:Description SuffixGroup B suitability GBFused (not for use in Canada) (not for marine use) S658*Factory assembled with lamps FAEmergency operation only Consult Cooper Crouse-Hinds*When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot beordered with /MT in the catalog number.
Accessories:Description Cat. #
Dome reflector RD739Angle reflector RA739
About the Battery: Bodine fluorescent battery pack ballasts are UL component recognized Sealed, maintenance-free, high temperature nickel cadmium Solid state chargers are sealed inside the ballast case; 90 minute illumination time; 10-year
life expectancy 2-year warranty During emergency use, 1 lamp has continuous operation A red indicator light indicates the battery is charging Wiring instructions for a "Push-to-Test" button is supplied with the fixture
10L
1158-1159.qxp 5/30/2011 11:17 AM Page 1159
-
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds1160
10L
10L EVLPFB EmergencyCompact FluorescentContinuous OperationLow Profile Luminaires
Cl. I, Div. 1, Groups B (GB Suffix), C, DCl. I, Zone 1, Groups IIB + H2(GB suffix), IIB, IIACl. II, Div. 1, Groups E, F, G; Class III,Simultaneous Presence
Marine & WetLocations3, 3R, 4, 4X; IP66Emergency Lighting
Pendant Mount
Wall Bracket Mount
Ceiling Mount
Stanchion Mount
Ceiling and bracket mounts have 4 hubs: 3 are plugged.
Complete Catalog Numbers as follows:Standard Voltage Ballasts
NEC/UL CEC/CSA (cUL)1. Voltage 120277V 5060 Hz 120V/60 Hz 347V 60 Hz
Suffix /UNV /120CAN /347
Example: EVLPFB02521/UNV2. Other Voltages Consult Cooper Crouse-Hinds
Note: For technical information on family trees, temperature performance data, dimensions,weights, and photometrics, refer to DMVF Series in Section 6L.
EVFPFB Fluorescent Emergency Lighting Three wire construction, for switching purposes, is standard on fluorescent emergency lighting. For energy conservation, luminaires can be switched off without affecting the emergency operation
feature.
*Test switch is remote mounted.Use Cooper Crouse-Hinds EDSC218 (Not furnished).
Ordering Information:
Pendant Wall Bracket Ceiling Stanchion
LuminaireBodyLessMountingModule &Guard
Watt
HubSize(In.)
With GuardCat. #
With GuardCat. #
With GuardCat. #
With GuardCat. # Cat. #
Fluorescent with Emergency Ballast High Power Factor Ballast (Min. P.F. 90%)
52W
3/4 EVLPFBA02521 EVLPFBBX02521 EVLPFBCX02521 EVLPFB05201 EVLPFBA03521 EVLPFBBX03521 EVLPFBCX0352111/4 EVLPFBJ04521
64W3/4 EVLPFBA02641 EVLPFBBX02641 EVLPFBCX02641 EVLPFB06401 EVLPFBA03641 EVLPFBBX03641 EVLPFBCX0364111/4 EVLPFBJ04641
1160-1161.qxp 5/30/2011 11:17 AM Page 1160
-
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds1146
10L
EXL Explosionproof Exit Sign
Factory-sealed
Cl. I, Div. 1 & 2, Groups C, DCl. I, Zone 1 IIBCl. II, Div. 1, Groups E, F, G
Applications:EXL Exit Signs are used: In locations deemed hazardous due to
the presence of flammable vapors orgases, or combustible dusts
In any building or enclosed area wherepeople work where illuminated exitsigns are required
To provide distinct, highly visible exitmarking
To indicate the direction of travel to exits
Features: Two incandescent lamps (not included)
wired in parallel to provide extramargin of light source reliability
Solid state circuit for extended lamp lifein AC units
Six inch red letters on white acrylic signpanel make word "exit" stand out boldlyand clearly
Edge lighting characteristic of sign panelmakes visibility excellent at all lightinglevels
Factory-sealed explosionproof housing Pendant, wall, and end bracket mounts
provide universal installation options Impact-resistant acrylic sign panel needs
no guard makes cleaning easy Internal rectifier extends lamp life
beyond 1,000-hour rated life reducesrelamping cost
Relamping tool provided
Standard Materials: Body copper-free aluminum Sign panel acrylic
Conduit Entrance: 3/4" hubs
Lamp Wattage: Two 60 watt, 60T10 clear lamps for AC units Two 25 watt, 25T10 clear lamps for DC units Lamps not included with luminaire
Electrical Ratings: 120VDC or 120VAC operation
Certifications andCompliances: NEC:
Class I, Groups C, DClass II, Groups E, F, G
UL Standard: 844 NFPA Life Safety Code No. 101-1991
Ordering Information:When ordering an EXL Series Exit Sign,you will need to specify:
(A) Voltage (120VAC or 120VDC)(B) Mounting (Wall, End Bracket, or
Pendant)(C) Exit Sign Designation
All units come standard with 3/4" hubs andexit signs with red lettering and whitebackground. Complete catalog numberingis as follows:
EXL (A) 2 (B) (C)(A) Voltage: 120VAC............ leave blank
120VDC .......................... D(B) Mounting: Wall................................. 1
End Bracket.................... 2Pendant .......................... 3
(C) Exit Sign Designation:A Single Face (Wall Mount)AA Double Face (End Bracket
& Pendant)AB Double Face, one side
arrowhead right, the otherno arrowhead (End Bracket& Pendant)
AC Double Face, one sidearrowhead left, the other noarrowheads (End Bracket &Pendant)
AD Double Face, one sidearrowhead both ends, theother no arrowheads (EndBracket & Pendant)
B Single Face, arrowheadright (Wall Mount)
BC Double Face, one sidearrowhead right, the otherarrowhead left (End Bracket& Pendant)
BD Double Face, one sidearrowhead both ends, theother arrowhead right (EndBracket & Pendant)
C Single Face, arrowhead left(Wall Mount)
CD Double Face, one sidearrowhead both ends, theother arrowhead left (EndBracket & Pendant)
D Single Face, arrowheadboth ends (Wall Mount)
DD Double Face, both sidesarrowhead both ends (EndBracket & Pendant)
10L
Pendant Style
End Bracket Style
Wall Style
MountingType
Sign PanelDescription
HubSize (In.)
ACCat. #
DCCat. #
Wall Single face 3/4 EXL21A EXLD21AEnd Bracket Double face 3/4 EXL22AA EXLD22AAPendant Double face 3/4 EXL23AA EXLD23AA
Options:Description Suffix Exit signs with green lettering on white background........................................................ GNUnit provided with epoxy powder coat............................................................................. S752277VAC (Order ECT413 Transformer Separately)
Temperature PerformanceData:(for both AC & DC operation):AmbientTemp. (C)
Class I (C, D)Class II (E, F, G)
SupplyWire C
25 T3C 150C40 T3C
1146-1147.qxp 5/30/2011 11:14 AM Page 1146
-
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds 1147
10L10LEXL Explosionproof Exit Sign
Factory-sealedDimensions
Pendant Style Wall Style
End Bracket Style
DimensionsIn Inches:
1146-1147.qxp 5/30/2011 11:14 AM Page 1147
-
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2012 Cooper Crouse-Hinds 1161
10L
Ex-Lite LED Exit Signs Cl. I, Div. 2, Groups A, B, C, DCl. I, Zone 1, AEx em ib IIC (NEC)Cl. I, Zone 1, Ex em ib IIC (CEC)Cl. II, Div. 2, Groups F, G (NEC)Cl. II, Div. 2, Groups E, F, G (CEC)
UL ListedIP66
The Ex-Lite Series of LED exit signs aredesigned for hazardous locations and areideally suited for marking escape routesand exits in potentially explosiveatmospheres.
The Ex-Lite Z is available as an AC onlyversion, while the Ex-Lite ZE is availablewith self-contained battery. As anemergency lighting luminaire with self-contained battery system, the Ex-Lite ZEfeatures a nickel cadmium battery withautomatic test and monitoring feature.
Applications: In harsh and hazardous environments
where illuminated exit signs are required
Features and Benefits:LED Technology: Long life (>50K hours) for years of
maintenance-free operation Energy-efficient for lower cost of
operation Low temperature operation with no loss
of illumination Rugged and durable light source for the
harshest of environmentsExit Sign System: Can be used in a hazardous location Conduit or cable entry Can be installed in moist, humid, rain,
and wet environments Universal input voltage 110VAC-277VAC
and 110VDC-250VDC reduces inventory Ex-Lite ZE with self-monitoring, self-
diagnostic, and test capability Premium heavy-duty nickel cadmium
battery 24-hour charge and recharge time
increases safety by recovering quicklyfrom outage
"EXIT" legend with alternative wings -left, right, or left and right; simple fieldmodification
Emergency lighting cycle three hours The housing of the luminaire is
constructed with a corrosion resistant,robust, lightweight aluminum alloymaterial and illumination of the sign isprovided with red, high-efficient LEDs
Certifications andCompliances: Class I, Division 2, Groups A, B, C, D Class I, Zone 1, AEx em ib IIC (NEC) Class I, Zone 1, Ex em ib IIC (CEC) Class II, Division 2, Groups F, G (NEC) Class II, Division 2, Groups E, F, G
(CEC) IP66 UL844 UL924/CSA22.2 No. 141-02 UL60079/CSA22.2 E60079 UL1203/CSA22.2 E6124-1-1-02
DimensionsIn (mm):
10L
Ordering Information:Catalog Number Ex Lite Z Ex Lite ZE
Description AC/DC Exit Sign with Battery
Light Source LED LEDLife of LED 50K hours 50K hoursRated Voltage, VAC 120V-277V 120V-277VFrequency, Hz 50/60 50/60Rated Voltage, DC 110V-250V 110V-250VPower Consumption 6VA 6VABattery N/A NiCad
Allowable Temperature Range -4F to 122F(-20C to 50C)41F to 95F(5C to 35C)*
Mounting Wall WallCable Entry Ex-e Ex-eConduit Entry 3/4" 3/4"Protection IP66 IP66
*Due to battery chemistry, the charging capacity will be limited at temperatures below 5C and above 35C.
Material Number 12191001005 12191130005
-
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds1150
10L
10L ELPS Light-PakEmergency LightingSystem
Cl. I, Div. 1 & 2, Groups C, DCl. I, Div. 1 & 2, Groups B, C, D(with suffix GB)Cl. II, Div. 1, Groups E, F, GCl. III
Cl. I, Zone 1Simultaneous PresenceWet LocationsNEMA 3, 3R, 12
Applications:ELPS Series Emergency Lighting Systemsare used: To provide safe, reliable illumination
indoors or outdoors to designated areasduring failure or interruption of power tothe normal lighting system
In areas made hazardous by thepresence of flammable gases andvapors, combustible dusts, or easilyignitible fibers and flyings
In areas where corrosion, vibration,moisture, dirt, and rough usage may beencountered
Where required by the National ElectricalCode, the Life Safety Code, or othercodes
In refineries, chemical and petrochemicalfacilities, grain processing, handling orstorage facilities, manufacturing plants,wastewater treatment facilities, andother areas where safe, reliable,hazardous area emergency lighting isneeded
Features: Compact factory-sealed luminaire
assemblies are each furnished with a 12watt tungsten-halogen lamp and innerreflector for appropriate photometrics inhazardous areas
Luminaire assemblies are fully adjustableand lockable on two axes to provideflexible and consistent light aimingcapabilities
Luminaire lens ring is threaded for easyrelamping and locks in place with hexhead set-screw; will not loosen due tovibration
Ground joint cover with external flangedesign permits large opening and easyaccess to internal components; studbolts in diagonally opposite corners ofbody ease cover removal and installation
Neoprene cover gasket seals outmoisture for superior protection ofinternal components against wetnessand corrosion
Lightweight, compact size, andmounting feet ease installation and allowplacement in confined areas
Two 1" NPT drilled and tapped conduitopenings, with plugs, are standard, forchoice of top or bottom feed
Factory-installed PUSH-TO-TESTpushbutton enables easy testing ofsystem
MAIN POWER ON pilot light indicatesAC power is being supplied to thebattery charger; pilot light jewel isthreaded for easy lamp replacement
Stainless steel drain minimizes moisturecollection; stainless steel breather withaluminum cap provides ventilation,minimizes moisture collection
CID 101 corrosion inhibitor device isprovided with each ELPS system to helpprotect electrical components andconnections
Rugged, long-life, maintenance-free,nickel cadmium battery provides 30watts of power for the required 11/2 hours
Solid state battery charger for long lifeand reliable service prevents deepdischarge by automaticallydisconnecting luminaires from battery Electrical Ratings:
Power Supply:Input:
120, 220/240, 277 VAC, 50 or 60 Hz0.5 Amps Maximum
Output: 12 VDCUL listed for 28 watts for 11/2 hours at 0 40C
Luminaires:Voltage: 12 VDCLamp Type: #789, miniatureTungsten halogen, G4, 2-pin, 14 watt
Standard Materials: Power supply enclosure and luminaire
assembly copper-free aluminum (lessthan 0.4 of 1% copper)
Standard Finishes: Power supply enclosure and fixture
assemblies powder coat epoxy paintfinish
Options:Description Suffix Remote mounted lamp head and arm....EVLA12 Key operated disconnect switch
as part of the ELPS502 emergency light system .......................... S794
Keyless operated designateddisconnect switch as part of theELPS502 emergency light system .......... S854
Ordering Information:Description Cat. #
Standard unit withadjustable heads............ ELPS502
Replacement powerinterior, includes circuitboard and battery pack ELPS K50
Power supply ................. ELPS50 Lamphead and arm ....... EVLA12 Exit sign, double sided
with EVI, red letters........ ELPS502 EXD Exit sign, double sided
with EVI, green letters.... ELPS502 EXD GN Exit sign, single or
double sided withGroup B EVA, red letters....................... ELPS502 EXD GB
Exit sign, single ordouble sided withGroup B EVA, greenletters ............................. ELPS502 EXD GB GN
Exit sign, single sidedwith EVI, red letters........ ELPS502 EXS
Exit sign, single sided with EVI, green letters................... ELPS502 EXS GN
Base unit comes standard with Class I, Division 1, Group B.
Certifications andCompliances: NEC:
Class I, Groups B, C, DClass II, Groups E, F, GClass IIISimultaneous Presence
NEMA: 3R, 12 (ELPS power supply) Suitable for wet locations (EVLA fixtures) Marine (EVLA fixtures) UL Standard:
844 Electric Luminaire HazardousLocations924 Emergency Lighting and PowerEquipment1203 Explosionproof and Dust-Ignitionproof Electrical Equipment
Life Safety Code:Section 5-9 (Emergency Lighting)
Suitable for Wet Locations NEMA 3, 3R, 12 Marine
Terminal block facilitates field wiringconnections
Instruction sheet and maintenancerecord card provided with unit in aprotective plastic envelope
A time delay is standard; time delay ispreset at factory for 5 minute delay butcan be field set for 5 seconds or 15minutes, thus allowing HID type lampstime to restrike and reach desiredillumination levels
Solid state battery charger will accept120, 220/240 or 277 VAC, 50/60 Hz
1150-1151.qxp 5/30/2011 11:15 AM Page 1150
-
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds 1151
10LELPS Light-PakEmergency Lighting System
Temperature Performance DataPhotometric DataDimensions and Weights
Temperature Performance Data:Cat. # Class T-numberMaximum Ambient Temperature 55C
EVLA12I T4AII* T3BIII* T3B
Maximum Ambient Temperature 40C
ELPS EVI T3CT4
ELPS EVA T3CT4*For Class II and Class III applications, fixtures must not be aimed more than 30 abovehorizontal (see diagram below).
Photometric Data:
Unit Net Weights: ELPS502 complete emergency lighting system 50 lbs. ELPS50 power supply 40 lbs. EVLA12 luminaire assembly 5 lbs.
Status Indication:LED Status Condition Meaning of the Indication
No light AC power is removed from the circuit
Steady light (no blinking) Fully charged
Light blinks once Charging
Light blinks twice Battery failure
Light blinks three times Circuit failure Light blinks four times Lamp failure
10L
DimensionsIn Inches:
1150-1151.qxp 5/30/2011 11:15 AM Page 1151
-
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2012 Cooper Crouse-Hinds1152
10L
LED N2LPS LIGHT-PAKEmergency Lighting System
Cl. I, Div. 2, Groups B, C, DCl. I, Zone 2Wet Locations, MarineNEMA 3, 3R, 4XAmbient 0C to 55C
Applications:LED N2LPS Light-Pak emergency lightingsystems are used: To provide reliable illumination for
egress areas during failure orinterruption of power to the normallighting system
In areas where flammable gases orvapors may become present due toabnormal, unusual, or accidentalconditions
In manufacturing plants, refineries,petrochemical and chemical plants,waste and sewage treatment facilities,oil terminals, food processing facilities,breweries, and other industrialmanufacturing or process industryfacilities subject to wet or corrosiveconditions
To illuminate machinery or panels duringa loss of AC power
Where moisture, dirt, dust, or corrosionwill limit the life and reliability of ordinaryemergency lighting systems
Where required by the NationalElectrical Code, the Life Safety Codeor other applicable codes
Outdoor applications
Features: Compact, factory-assembled luminaire
featuring LED lamps for improved lumenperformance, on-time, and lamp life
Nonmetallic, enclosed, and gasketedhousing provides corrosion protection inthe most extreme environments
Durable and marine rated LED lamphead assemblies provide protectionagainst water ingress, corrosion, andimpact
High temperature rated nickel cadmiumbattery for reliable operation up to 55Cambient
Solid state battery charger for long lifeand reliable battery operation preventsdeep discharge by automaticallydisconnecting the battery from theluminaire
Factory-installed "push-to-test" button Self-test, monitoring, and diagnostics
reduce costly maintenance checks Remote luminaire head assemblies (one
or two) are available for mounting ofluminaire heads away from main powersystem
Stainless steel drain minimizes moisturecollection
Standard battery disconnect switch(Krydon unit)
Temperature PerformanceData:Based on 55C ambientCat. # Class I, Division 2
N2LPS (all) 40C - T5; 55C - T4AN2RF (all) T5Note: Ambient temperature at which the Light-Pak
system is rated is 0C to 55C. Operation attemperatures outside this range will affect thebattery life and/or charging performance.
National Electrical Code and Life Safety Code areregistered trademarks of the National Fire ProtectionAssociation, Inc.Noryl is a registered trademark of General ElectricCompany.
Standard Materials: Power supply and remote luminaire
enclosures Krydon fiberglass-reinforced polyester
LED lamp head assembly epoxypowder coated stainless steel
Exterior hardware nylon, plasticcoated, and stainless steel
Cover gasket Hypalon synthetic rubber
Electrical Ratings: Power supply
Input: 120, 220, 230, 240, or 277 VAC,50 or 60 Hz; 28 watts max.Output: 12 VDC
Luminaire heads Voltage: 12 VDC; Lamp: 3 watt LEDTotal lumen output: 80
Certifications andCompliances:NEC/CEC: Class I, Division 2, Groups B, C, D,
Zone 2UL Standards: 1598A (Supplemental Requirements for
Luminaires for Installation on MarineVessels)
924 (Emergency Lighting and PowerEquipment)
844 (Electric Luminaires HazardousLocations)
CSA Standards: C22.2 No. 141-M1985 unit equipment
for emergency lighting C22.2 No. 137-M1981 non-incendive
electrical equipment for use in Class I,Division 2 hazardous locations
Life Safety Code NFPA101 Section 5-9 (Emergency Lighting)
Marine wet locations suitability, Type 4X
Unit Net Weights: N2LPS12222 16 lbs. N2LPS12220 12 lbs. N2RF1221 8 lbs. N2RF1222 9 lbs.
10L
Note: Battery time in emergency mode is 90 minutes.
-
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds 1153
10LCl. I, Div. 2, Groups B, C, DCl. I, Zone 2Wet Locations, MarineNEMA 3, 3R, 4XAmbient 0C to 55C
Note: Up to four (4) remote LED lamp assemblies can be connected to the N2LPS12222. Up to six (6) remote LED lamp assemblies can beconnected to the N2LPS12220.
Wire Sizing for Remote Installation:For Copper Wire Running Distance (ft.) Between Power Supply and Remote Luminaire
Load In Watts Load In Watts
Wire Size 8 16 24 32 Wire Size 8 16 24 32
16 AWG 26 13 6 3 10 AWG 106 53 26 1314 AWG 42 21 10 5 8 AWG 168 84 42 2112 AWG 66 33 16 8 6 AWG 270 135 67 33Maximum distance to limit line voltage drop to 5%.
Dimensions (N2LPS):
16.0
13.5
18.0
7.5
14.513.8
5.0
1.1
7.4
Standard N2LPS LED Light-Pak
LED N2LPS LIGHT-PAKEmergency Lighting System
10L
Ordering Information:Description Cat. #
28 watt, 12 volt power supply assembly with two 3 watt LED lamp heads N2LPS1222228 watt, 12 volt stainless steel power supply assembly with two 3 watt LED lamp heads N2LPS12222 SS28 watt, 12 volt power supply assembly less luminaire heads N2LPS12220*Remote luminaire assembly with one 3 watt LED lamp head N2RF1221*Remote luminaire assembly with two 3 watt LED lamp heads N2RF1222*28 watt, 120V LED Light-Pak with single sided exit sign** N2LPS12222/120 EXS DR039173428 watt, 277V LED Light-Pak with single sided exit sign** N2LPS12222/277 EXS DR039173428 watt, 120V LED Light-Pak with double sided exit sign** N2LPS12222/120 EXD DR039173428 watt, 277V LED Light-Pak with double sided exit sign** N2LPS12222/277 EXD DR0391734*Not cUL approved. UL Listed only.**Exit sign operates in both normal and emergency mode.
1152-1153.qxp 5/30/2011 11:15 AM Page 1153
-
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds1154
10L
10L
Dimensions (N2LPS):
EXS, EXD Option N2LPS LED Light-Pak with Optional Emergency Exit Luminaire
Dimensions (N2RF):
11.77
3.83
9.50
7.27
3.83
9.50
4.38
Detail Indication Logic:Status Indication Status Description Status Definition
No Light AC Power Removed from Circuit* Steady Light (No Blinks) Fully Charged*-* Light Blinks Once Battery Charging**-** Light Blinks Twice Battery Failure***-*** Light Blinks Three Times Circuit Failure
LED N2LPS LIGHT-PAKEmergency Lighting System
Cl. I, Div. 2, Groups B, C, DCl. I, Zone 2Wet Locations, MarineNEMA 3, 3R, 4XAmbient 0C to 55C
1154-1155.qxp 5/30/2011 11:16 AM Page 1154
CPMVFB Fluorescent Emergency Luminaire.pdf11551156
DMVFB Fluorescent Emergency Luminaire.pdf11571158
EVLPFB Fluorescent Emergency Luminaire.pdf11591160
EXL Incandescent Exit Sign.pdf11461147
Light-Pak ELPS Emergency Lighting System.pdf11501151
Light-Pak LED N2LPS_10L.pdf11531154