rockfon medicare accessoriesrwiumbraco-rfn.inforce.dk/media/3602077/uk-rockfon...*the airtightness...

6
ROCKFON ® MediCare ® Accessories Sm1 (35) CI/SfB APRIL 2017

Upload: vuphuc

Post on 01-Apr-2018

228 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: ROCKFON MediCare Accessoriesrwiumbraco-rfn.inforce.dk/media/3602077/uk-rockfon...*The airtightness of ROCKFON MediCare Air has been documented. Hold Down Clips Recommended clip layout

ROCKFON® MediCare® Accessories

Sm1(35)CI/SfB

ApRil 2017

Page 2: ROCKFON MediCare Accessoriesrwiumbraco-rfn.inforce.dk/media/3602077/uk-rockfon...*The airtightness of ROCKFON MediCare Air has been documented. Hold Down Clips Recommended clip layout

To seal custom-cut tiles, we provide an aluminum foil adhesive tape. It has good adhesion on the tile and eliminates fibre emission and dust which is essential in healthcare environments where particle

emissions must be avoided. It is quick and easy to use. The sealing tape is air-tight as well as abrasion and humidity resistant. It is 75mm wide and supplied in 50m rolls.

Sealing Tape

1. Cut

4. Press

7. Fold up & press

2. Measure edge+10mm & peel

5. Flip tile to back

8. Form-fold corner

3. Align 5mm overlap on front

6. Peel

9. Flip tile to front & finish

Page 3: ROCKFON MediCare Accessoriesrwiumbraco-rfn.inforce.dk/media/3602077/uk-rockfon...*The airtightness of ROCKFON MediCare Air has been documented. Hold Down Clips Recommended clip layout

Keeping the ceiling tile secure in the grid system facilitates, among other things, mechanical cleaning/disinfection of the tile or stability in pressurised areas where airtightness is required. We recommend placing clips every 15mm from the corners, spacing additional clips evenly between them: 8 fixing points for 600x600mm tiles and 12 fixing points for 1200x600mm tiles.

There are two types of hold down clipsavailable:1. HDC12. HDC2

In combination with 38mm high Chicago Metallic grids, HDC1 is used for 20mm thick tiles and HDC 2 for 25mm thick tiles.

These clips can be manually altered to function as a one side hold down clip.

We recommend affixing custom cut tiles along the perimeter trim with an appropriate silicone sealant.

*The airtightness of ROCKFON MediCare Air has been documented.

Hold Down Clips

Recommended clip layout

custom x

custom

600 x

custom

1200 x

custom

600 x

custom

custom x

custom

custom x

600

600 x 600 light fixture

1200 x

600

600 x

600

custom x

600

custom x

600

600 x

600

1200 x

600

600 x

600

custom x

600

custom x

600

600 x

600

1200 x

600

600 x 600 light fixture

custom x

600

custom x

custom

600 x

custom

1200 x

custom

600 x

custom

custom x

custom

HDC 1 (used where tiles meet tiles)

HDC 2 (used where tiles meet tiles)

Page 4: ROCKFON MediCare Accessoriesrwiumbraco-rfn.inforce.dk/media/3602077/uk-rockfon...*The airtightness of ROCKFON MediCare Air has been documented. Hold Down Clips Recommended clip layout

We have developed an air-tight inspection hatch in which a ROCKFON ceiling tile (ROCKFON MediCare Plus / ROCKFON MediCare Air surface) is glued into the hatch for a more uniform ceiling surface and better acoustics.

The hatch is made of galvanised steel, powder-coated white. It is fitted with 2 locking mechanisms and is suitable for Chicago Metallic T24 Click 2890 exposed grid, lay-in ceilings. It is available in 600x600mm.

A polyester gasket seal ensures the air-tightness between the hatch´s frame and door. The frame of the hatch sits behind the T-grid. Although it is fairly light (5.25kg including tile), additional hangers on the grid may be necessary to improve stability depending on the installation system.

The access hatch should be independently supported and braced to prevent the tile’s additional weight, and operating forces exerted on it during installation and operation, being transferred to the lightweight ceiling system.

If damaged, the ceiling tile can easily be replaced with a new tile by demounting the locks.

Air-tightness of the inspection hatch in combination with ROCKFON MediCare Air is documented. The use of neoprene foam tape on the grid with a pre-applied gasket seal is recommended to improve the air-tightness performance of the entire ceiling / hatch system.

A summary of these results is available upon request. For further information, please contact ROCKFON customer service.

ROCKFON Air-tight inspection hatch

Easy access to services

Uniform ceiling surface and easy opening

Page 5: ROCKFON MediCare Accessoriesrwiumbraco-rfn.inforce.dk/media/3602077/uk-rockfon...*The airtightness of ROCKFON MediCare Air has been documented. Hold Down Clips Recommended clip layout
Page 6: ROCKFON MediCare Accessoriesrwiumbraco-rfn.inforce.dk/media/3602077/uk-rockfon...*The airtightness of ROCKFON MediCare Air has been documented. Hold Down Clips Recommended clip layout

Understanding the unique performance of ROCKFON stone wool productsBelow is an explanation of ALL the performance icons and certification for our complete range of ROCKFON stone wool products. For product specific performance, please refer to the information on the individual product datasheet.

Sound absorptionSound absorption is measured in accordance with ISO 354. Sound absorption data αp, αw and absorption class are calculated in accordance with ISO 11654. Sound absorption properties of islands and baffles are quantified by the equivalent sound absorption area Aeq expressed as m² per item.

Room-to-room sound insulationRoom-to-room sound insulation Dn,f,w (C;Ctr) is measured in accordance with ISO 10848-2.

Direct sound insulationSound reduction index Rw (C;Ctr) is measured in accordance with ISO 140-3.

Reaction to fireReaction to fire is classified in accordance with EN 13501-1.

Fire protectionThe stone wool core of ROCKFON products is non-combustible with a melting point of more than 1000°C and provides fire protection. Some ROCKFON ceilings have been tested and classified in accordance with European norm EN 13501-2 and/or national norms.

light reflectionLight reflection expressed in % is measured in accordance with ISO 7724-2.

Humidity & sag resistanceROCKFON ceiling tiles are dimensionally stable even at humidity levels of up to 100% relative humidity and can be installed at all temperatures ranging from 0°C to 40°C. They can be installed during the very early stage of the build (when windows are not fully sealed). Their lightweight yet stable non-hygroscopic character minimises the final weight of the fully-installed ceiling. ROCKFON ceiling tiles are predominantly classified as Class 1/C/0N in accordance with EN 13964. Certain module sizes (width above 700mm) are Class 2/C/0N.

Surface durabilityThe surface of some ROCKFON products is specially treated to provide enhanced durability and dirt resistance.

CleaningVacuum: The surface can be vacuum cleaned with a soft brush attachment.Damp cloth: The surface can be cleaned using a damp cloth or sponge with a slightly alkaline detergent (pH between 7 and 9) without alcohol, ammonia or chlorine. This may render the surface slightly shinier, so we recommend cleaning the entire surface evenly.

HygieneStone wool provides no sustenance to the following microorganisms tested in accordance with JIS Z 2801:2000 and ASTM C 1338-96:

– Escherichia coli– Staphylococcus aureus– Methicillin-resistant staphylococcus aureus (MRSA)– Stachybotrys chartarum – Penicillium brevicumpactum– Alternaria tenuissima – Aspergillus niger – Sporobolomyces roseum – Rhodotorula rubra

Clean roomClean room classification is measured in accordance with ISO 14644-1.

Thermal insulationThe thermal conductivity of products with a thickness ≥ 30mm is measured in accordance with EN 12667 and expressed in mW/mK. Thermal resistance is expressed in m²K/W.

ROCKFON | ROCKWOOL Limited T/A ROCKFON 14th Floor, Chiswick Tower, 389 Chiswick High Road, London W4 4AL

Tel: +44 (0) 208 222 7457 | Fax: +44 (0)20 8222 7458 | www.rockfon.co.uk

04.2017 | Subject to alterations in range and product technology without prior notice. ROCKFON accepts no responsibility for printing errors.