Versatile ceiling system Quick and easy to install Visible grid Easy integration with services and fittings E24 E24 A15/A24 Ceiling comprising Chicago Metallic T24 Click 2890 grid and ROCKFON tiles System description ROCKFON SYSTEM T24 A/E

Upload: truonghanh

Post on 12-Apr-2018

228 views

Category:

Documents


2 download

TRANSCRIPT

Versatile ceiling system

Quick and easy to install

Visible grid

Easy integration with services and fittings

E24 E24A15/A24

Ceiling comprising Chicago Metallic T24 Click 2890 grid and ROCKFON tiles

System description

ROCKFON SYSTEM T24 A/E

ROCKFON SYSTEM T24 A/E ROCKFON SYSTEM T24 A/E

2

ROCKFON tiles in the following sizes, with A15, A24 and E24 edge details are suitable for installation with ROCKFON System T24 A/E:600 x 6001200 x 6001200 x 12001200 x 900900 x 900900 x 600

ROCKFON System T24 A/E is a ceiling comprising a 24mm wide exposed grid made from galvanised steel with a smooth white* visible surface and square (A edge) and / or rebated, tegular (E edge) tiles. It comprises main runners, cross tees (available in many lengths), perimeter trims and a variety of accessories. All the grid profiles have a uniform height of 38mm ensuring smoother integration of services and fittings.

Systems are also available in an Enhanced Corrosion Resistant (ECR) format for use in harsh environments.

ROCKFON System T24 A/E can be either suspended or directly fastened to the soffit usinga variety of hangers.

* Other colours are available to order.

For general installation guidance, refer to the ROCKFON Installation Guide for:Chicago Metallic T24 Click 2890Chicago Metallic T15 Click 2790

DESCRIPTION

Cross tees have an audible "click" to confirm they are in place, making installation and demounting quick and easy.

Full height on all profiles to provide easier integration opportunities with fittings.

A15/A24

E24

E24

This system can create exposed and semi-concealed ceilings in 24mm width using A and E edge tiles.

6 3

21

745

1200mm

max.1200mmmax. 450mm

1200mm

ROCKFON SYSTEM T24 A/E

3

SYSTEM COMPONENTS AND CONSUMPTION GUIDE

MAIN RUNNER AND CROSS TEES

PERIMETER TRIMS

ACCESSORIES

QUANTITY/M2 1 2 3 4 5 6 7* 8Main runners and suspension hangerspositioned at 1200mm centres

Main runner

T24 3600

Cross teeT24 600

Cross teeT24 1200

W Shadow moulding wall

angle(L: 3050mm)

Perimeter angle trim

(L: 3050mm)

Suspension hanger

Direct suspension

clip

Cross teeT24 900

MODULE SIZE (mm)

600 x 600 0.84 lm 0.84 lm 1.68 lm 1) 1) 0.70 pcs 0.70 pcs -900 x 600 0.84 lm - 1.12 lm 1) 1) 0.70 pcs 0.70 pcs 0.84 lm1200 x 600 0.84 lm - 1.68 lm 1) 1) 0.70 pcs 0.70 pcs -900 x 9002) 1.12 lm - - 1) 1) 0.93 pcs 0.93 pcs 1.12 lm1200 x 900 0.84 lm - 1.12 lm 1) 1) 0.70 pcs 0.70 pcs -1200 x 1200 0.84 lm - 0.84 lm 1) 1) 0.70 pcs 0.70 pcs - 1) Consumption depends on room size. 2) Main runners positioned at 900mm centres. Suspension hangers positioned at 1200mm centres. *) Choose from three different depths of direct suspension clips - 50, 80 and 100mm. Max. load capacity is 45 Kg/pc when used with pin ref:165421.

1. MAIN RUNNER T24 3600

4. W SHADOW MOULDING WALL ANGLE (L: 3050mm)

6. SUSPENSION HANGER

3. CROSS TEE T24 1200

7. DIRECT SUSPENSION CLIP(Three depths available)

2. CROSS TEE T24 600

5. CROSS TEE T24 1800

5. PERIMETER WALL ANGLE TRIM (L: 3050mm)

Use with pin 165421

(5 No. cross tee slots)

ROCKFON SYSTEM T24 A/E ROCKFON SYSTEM T24 A/E

4

Code Component descriptionHeight (mm)

Length (mm) Colour

166837 Main runner T24 Click/Hook 38 3600 White 001 24 Slots 75 150 22 x 150 75

163730 Cross tee T24 Click 38 300 White 001 No Slots 300

166862 Cross tee T24 Click 38 600 White 001 1 Slot 300 300

166863 Cross tee T24 Click 38 1200 White 001 3 Slots 300 300 300 300

170077 Cross tee T24 Click 38 1800 White 001 5 Slots 300 300 3 x 300 300Components available in special lengths and slottings on request.

POSITION OF SLOTS AND SUSPENSION HOLES

170595

Perimeter wall angle trim

Main runner and cross tees

170658

W Shadow moulding wall angle

CROSS SECTIONS

ROCKFON SYSTEM T24 A/E

5

12001200

1200900

600900

900900

1

Main runnerCross teeHanger

1200600

1

3 3

3

3 3

600600

1200mm 900mm

1200mm

1

8

8

21 1 1 1

GRID LAYOUT OPTIONS AND HANGER LOCATION

Below are examples of perimeter finishing. Further details can be found on www.rockfon.co.uk

3. W shadow moulding wall angle with A edge tile

2. Shadow batten and perimeter wall angle trim with E edge tile

4. Connection to plasterboard with plaster connection bracket shown with E edge tile

5. Connection to plasterboard with plaster connection bracket shown with A edge tile

1. Perimeter wall angle trim with E edge tile

PERIMETER FINISH OPTIONS

ROCKFON SYSTEM T24 A/E ROCKFON SYSTEM T24 A/E

6

Tile thickness (mm) Module size (mm) D (mm)

15 - 20 600 x 6001200 x 600

900 x 600900 x 900

1600 x 6001800 x 6002100 x 6002400 x 600

100

15 - 25 1200 x 1200 1200 x 900 100

40 - 100 600 x 600 1200 x 600 200

The system loading capacity is determined based on a maximum deflection of each component equal to 1/500 of the span or the cumulative deflection of all the structural components which do not exceed 4mm. The loading capacity is shown as evenly distributed load in kg/m2. Grid weight is inclusive; tile weight is not included.

MINIMUM INSTALLATION DEPTH (mm)

SYSTEM LOADING CAPACITY

For further information, visit our online CAD library at www.rockfon.co.uk

Generate specifications for our products from the website. Explore an extensive library of reference projects at www.rockfon.co.uk

D = Minimum installation depth for easy tile installation and demountability. Depth when using direct hangers is minimum 50mm.

Kg/m²

Hanger distance (mm) Module size (mm)

Maximum deflection

2.5mm 3.3mm 4.0mm

1200 600 x 600 9.9 13.4 16.5

1200 600 x 1200 10.9 14.6 17.9

D

ROCKFON SYSTEM T24 A/E

7

Junction between ceiling and wall orother vertical surfaceThe perimeter trim should be fastened to verticalsurfaces at the required level using appropriate fixings at nominal 450mm centres. Ensure that butt joints between adjoining lengths of trim are neat and that the trim is free from kinks and remains true and level. For the best aesthetics, use as long a length of trim as possible. The minimum recommended cut length is 300mm. Timber trims, timber shadow battens and metal shadow mouldings should not be used with fire resisting/protecting ceilings.

Junction between ceiling and curvedvertical surfaceThe use of a preformed curved perimeter trimis the most appropriate method. This should beinstalled as described above. ROCKFON canprovide details of curved perimeter trims onrequest.

CornersPerimeter trims should be neatly mitred at allcorner joints. Overlap mitres are acceptableon metal trims on internal corner joints unlessspecified otherwise.

PERIMETER FINISHING

ROCKFON tiles have a matt white or coloured surface and are directional. To ensure a consistent appearance to the finished ceiling, it is important that all tiles are installed in one direction, indicated by the arrow printed on the back of the tile.

Tile installationWe recommend the use of clean nitrile or PU coated gloves when installing ROCKFON tiles in order to avoid fingerprint marking on the surface.

For an optimum work environment, we recommend installers always observe common work practices and follow installation advice as shown on our packaging.

ROCKFON tiles are easy to cut by using a sharp knife. Apply ROCKFON edge paint to any visible cut edges.

Unless specified otherwise, the ceiling shouldbe set out symmetrically and where possible,perimeter tiles should be greater than 200mmin width.

The hangers should be fastened with appropriate top fixings and to the main runners at 1200mm centres. Main runners should be positioned at 1200mm centres (900mm centres for 900mm x 900mm tiles) and levelled at the appropriate ceiling height. Main runner joints should be staggered and there should be a hanger positioned within 150mm of the fire expansion point and within 450mm of the end of the main runner where it terminates at a perimeter. Additional hangers may be necessary to support the weight of ceiling services.

When using direct hangers, a fixing nail shouldbe used to lock the hanger on to the bulb of themain runner.

1200mm x 1200mm moduleFit 1200mm cross tees between the main runners at 1200mm centres.

1200mm x 900mm moduleFit 1200mm cross tees between the main runners at 900mm centres.

1200mm x 600mm moduleFit 1200mm cross tees between the main runners at 600mm centres.

600mm x 600mm moduleAs 1200mm x 600mm module but intersect1200mm cross tees with 600mm cross tees at1200mm centres parallel to the main runner.

900mm x 900mm moduleFit 900mm cross tees between the main runnersat 900mm centres.

900mm x 600mm moduleFit 1200mm cross tees between the mainrunners at 900mm centres, intersect with 900mm cross tees at 1200mm centres parallel tothe main runner.

MAIN GRID

TILE INSTALLATION

For general installation guidance, refer to the ROCKFON Installation Guide for:Chicago Metallic T24 Click 2890Chicago Metallic T15 Click 2790

ROCKFON SYSTEM T24 A/E ROCKFON SYSTEM T24 A/E

8

ENHANCED CORROSION RESISTANCE (ECR)

FIRE RESISTING / PROTECTING CEILINGS

This grid provides excellent longevity and complies with the requirements of Class B BS EN 13964.

Chicago Metallic grids are also available in an Enhanced Corrosion Resistant (ECR) format for use in harsh environments such as swimming pools.

Our ECR grids comply with the requirements of Class D BS EN 13964.

This system can be used in conjunction with many ROCKFON ceiling tiles to create a variety of specifically designed fire resisting/protecting ceiling constructions.

Many ROCKFON ceiling solutions have been tested and subsequently independently assessed in accordance with BS 476 Parts 21, 22 and 23.

For further details of the tiles, module sizes andapproved constructions, please contact ROCKFON.

Hold down clipsA variety of hold down clips suitable for usewith the many ROCKFON tiles are available for this system.

For fire resisting/ protecting ceilings, tiles should be clipped at the rate of 2 clips per 600mm edge and 3 clips per 1200mm edge.

In small rooms, entrance areas, staircases andother areas which may be subject to pressuredifferences between room and ceiling void, it isrecommended to alleviate pressure build up with the use of vents or grills. Alternatively, in some situations, clips can be used to secure the tiles into the grid system.

Hangers Wire and adjustable rod hangers should be fastened through the holes in the stalk of the main runners. Wire hangers should be passed through the hole and wrapped at least three times around itself. Adjustable rod hangers should be orientated and connected to main runners so that the lower sections of the hangers run in the same direction.

Top FixingsTop fixings are available from many specialist suppliers. It is important to be sure that the top fixings used to support the ceiling are appropriate for the specific soffit and that they provide adequate pull out strength when installed.

Service IntegrationA variety of service installations and lights can be easily integrated into this system.

Service installations should not be supported on the ceiling tile alone. Service loads should always be adequately spread on the back of the tile or transferred to the grid system using appropriate support arms or yokes. Alternatively, the service should be independently supported.

Please contact ROCKFON Technical Support for further advice.

ACCESSORIES

ROCKFONA trading division of ROCKWOOL Limited26-28 Hammersmith Grove, London, W6 7HATel: +44 (0) 208 222 7457Fax: +44 (0) 208 222 7458www.rockfon.co.uk

We believe our acoustic stone wool and metal solutions for ceilings and walls are a fast and simple way to create beautiful, comfortable and safe spaces.

Easy to install and durable, they protect people from noise and the spread of fire. They are our way of making a constructive contribution towards a sustainable future.

Create and Protect is what drives us. It means putting people first, sharing success and maintaining trust.

It’s our rock-solid promise to you. At ROCKFON, Create and Protect is what we do - and it’s inspired by you.

| All colour codes m

entioned are based on the NCS - N

atural Colour System®

© property of and used on licence from

NCS Colour A

B, Stockholm 2010.

Subject to alterations in range and product technology without prior notice. RO