regd.off: # 5-11-16 venkateshwara nagar colony meerpet · pdf fileregd.off: # 5-11-16...

11

Upload: nguyendang

Post on 02-Feb-2018

228 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Regd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet · PDF fileRegd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet Moulali Hyderabad – 500 040 A.P.India Tel: +91-040-27790886
Page 2: Regd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet · PDF fileRegd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet Moulali Hyderabad – 500 040 A.P.India Tel: +91-040-27790886

Regd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet Moulali Hyderabad – 500 040 A.P.India Tel: +91-040-27790886 / 39188320 / 9030299892 Email: [email protected] www.masinstruments.com

Page 3: Regd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet · PDF fileRegd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet Moulali Hyderabad – 500 040 A.P.India Tel: +91-040-27790886
Manzoor
Textbox
Manzoor
Textbox
Manzoor
Textbox
Manzoor
Textbox
Manzoor
Textbox
Manzoor
Textbox
Manzoor
Textbox
Page 4: Regd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet · PDF fileRegd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet Moulali Hyderabad – 500 040 A.P.India Tel: +91-040-27790886

Description

ierra Instruments’ Smart-Trak® 50 Series is a digital gas mass

flow controller designed to meet the low-cost budgetary requirements

of OEM's while maintaining excellent quality and performance. Inspired

by the need for accurate and reliable gas mass flow control at an OEM

price, the 50 Series delivers by building on the same core sensor, LFE

and valve technology found in our award-winning Smart-Trak 100

Series, all backed by industry best off-the-shelf fast product delivery

and Sierra's style of personalized customer support. Our 50 Series has

a standard accuracy of +/- 1.5% of full scale. The flexible and powerful

direct-acting control valve sets it apart from the competition by

minimizing leak-by, while offering a 300 ms response time to setpoint

changes at +/- 0.25% repeatability.

It is our philosophy that core sensor technology must be of the

highest quality and performance to make an excellent MFC. In contrast

to the many wetted parts of CMOS and MEMS flow sensors, Sierra uses

its most advanced 316L stainless steel platinum-wound capillary sensor

technology ensuring the very best mass flow control for nearly any

clean gas. As a result, the 50 Series shares the same advanced sensor as

the flagship Smart-Trak 100 Series, while incorporating a slightly varied

valve and laminar flow element design also inspired by the original

Smart-Trak. A more efficient manufacturing process, a streamlined

design, and our partnership with a very strong supplier base combined

to make the 50 Series a reality.

Experience our passion for flow with the 50 Series in your next

application.

Economical OEMDigital Mass Flow ControllerDigital Mass Flow Controller

ControllerController

Digital Mass Flow

Industry best off-the-shelf delivery

Accuracy: +/- 1.5% full scale for common gases (Air, Ar, CO2, CO, CH4, He, H2, O2, N2)

Repeatability: +/- 0.25% full scale

All the performance features of a digital mass flow controller at an OEM price

Control gas mass flow rates to 50 slpm (nlpm)

Advanced 316L SS platinum sensor technology and patented LFE provide excellent linear performance

Available in both aluminum and 316 stainless steel flow bodies with Viton® elastomers

Local display and digital setpoint control with optional analog setpoint/output signals

RS-232 interfaces easily with PLC or workstation (user software and communication cables supplied)

RS-485 (addressable)

Dual I/O DB9 comm ports for installation flexibility

Field adjustable zero and span

Powerful direct-acting control valve minimizes leak-by

300 ms control valve time constant

Small footprint facilitates replacement of older MFC's

CE Approved

Features

S

Smar

t-Tra

k®Sm

art-T

rak®

®®

Smar

t-Tra

k 5

0 Se

ries

Page 5: Regd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet · PDF fileRegd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet Moulali Hyderabad – 500 040 A.P.India Tel: +91-040-27790886

Performance Specifications

Accuracy+/- 1.5% of full scale including linearity over 32° to 122°F (0° to 50°C) and 5 to 145 psig (0.3 to 10 barg) for common gases: Air, Ar, CO2, CO, CH4, He, H2, O2, N2. +/- 3.0% of full scale for other gases.

Repeatability +/- 0.25% of full scale

Temperature Coefficient0.025% of full scale per °F (0. 05% of full scale per °C ), or better

Pressure Coefficient0.01% of full scale per psi (0.15% of full scale per bar), or better

Response Time300 ms time constant; two seconds (typical) to within +/- 2% of final value including setting time. May be tuned to be faster or slower (consult factory)

Operating Specifications

GasesAll neutral, non-contaminated dry and clean gases compatible with wetted materials aluminum, stainless steel and Viton®All neutral, non-contaminated dry and clean gases compatible with wetted

®All neutral, non-contaminated dry and clean gases compatible with wetted

Mass Flow RatesThe 50 Series can be calibrated for any gas compatible with viton, aluminum and stainless steel, using any units, to either normal or standard conditions, for flow rates up to 50 slpm air equivalent. Standard calibrations are available for ranges (slpm air equivalent) from 20 sccm/nccm to 50 slpm/nlpm.

For measuring or controlling flows below 5 sccm, please consider Micro-Trak™ Model 101. Above 50 slpm, please consider the Smart-Trak®For measuring or controlling flows below 5 sccm, please consider Micro-Trak™

®For measuring or controlling flows below 5 sccm, please consider Micro-Trak™

100 Series

Gas Pressure:145 psig (10 barg) maximum, burst tested to 225 psig (15 barg)

Differential Pressure Requirement 15 to 20 psi (1.0 to 1.3 bar) see table

Gas and Ambient Temperature32°F to 122°F (0 to 50°C)

Leak Integrity5 X 10-9Leak Integrity

-9Leak Integrity

atm cc/sec of helium maximum

Power RequirementsMeter: 15 or 24 VDC (+/- 10%) 85 mA regulatedController: 24 VDC (+/-10%), 315 mA, regulated, RS-485 option adds 130 mA

Control Range5 to 100% of full scale flow (20:1) at published accuracy. Automatic shut-off off at 4.9% of full scale

Output and Command (Setpoint) Signal• RS-232

Optional:• Linear 4 -20 mA, 500 ohms maximum load resistance. • Linear 0 -5 VDC• RS-485 Addressable (no analog outputs)• Zero, span, and setpoint are field adjustable via supplied user software and RS-232 communications cable

DisplayFlow rate, units, full scale, and setpoint. Display may be mounted on the front or back of the unit.

Wetted Material

Anodized aluminum or 316 stainless steel flow body. 316L stainless steel sensor tubes; Viton® O-rings and valve seats.

Physical Specifications & Dimensions

50 Series - Front View 50 Series - Side View

50 Series - Bottom View

1 (69)

1.5 (103.5)

2 (137.9)

4 (275.9)

7.5 (517.3)

.45 (31.0)

.45 (31.0)

.50 (34.5)

.60 (41.4)

.80 (55.2)

1

2

3

4

5

7

6

slpm

0.20

.200

1.00

5.00

10.00

Minimum Delta psid (mbar)(Controller)

Designator Pressure Drop psid (mbar)(Meter)

15 (1034.6)3.0 (206.9)50.00

12.5 (862.1)1.2 (82.8)20.00

1/4 Brass compression

1/8 Brass compression

Note: Units in inches (mm in parenthesis)

Pressure Drop (1/4" standard fittings)

Page 6: Regd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet · PDF fileRegd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet Moulali Hyderabad – 500 040 A.P.India Tel: +91-040-27790886

Software Screen Shots

50 Series - No DisplayStainless Steel flow body shown

50 Series - With DisplayAluminum flow body shown

Communications Setup

User Program Interface

Page 7: Regd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet · PDF fileRegd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet Moulali Hyderabad – 500 040 A.P.India Tel: +91-040-27790886

Ordering the 50 Series

CERTIFICATES5PC 5 Point Calibration CertificateMC Material Certificates--US Mill certs on all wetted parts CC Certificate of Conformance

O2C Oxygen Cleaning

FLOW BODY MATERIALAL Aluminum Body (Viton® elastomers only)SS 316 Stainless Steel Body (Viton® elastomers only)

PILOT MODULE DISPLAYNR No DisplayDD Digital Display (front mounted)DDB Digital Display (back mounted)

INLET/OUTLET FITTINGS1 1/8" SS Compression (Max 5 slpm) 2 1/4" SS Compression

5 1/4" VCO 8 1/4" VCR

INPUT POWERPV1M 15 VDC for meters PV2 24 VDC for all instruments

OUTPUT SIGNAL/SETPOINTV0 RS-232 ( no analog output )

V1 0 to 5 VDC linear output signal and setpoint

PARENT NUMBERC50L Mass Flow ControllerM50L Mass Flow Meter (Aluminum body only)

10 6 mm Compression 13 1/4" FNPT

21 1/4" Brass Compression20 1/8" Brass Compression

ELECTRICAL CONNECTIONS50-C9 ( ) Communication cable. Includes cable with D9 mating connector, fly leads.

(Length in parenthesis)

50-C9RS323 ( ) Cable with D9 mating connector + D9 serial (Length in parenthesis)

Note: CE and ISO certificates are available for download from

STANDARD CALIBRATION: FULL SCALE FLOW RANGES ("F" = Standard "N" = Normal)F1 or N1 20 sccm or nccmF2 or N2 200 sccm or nccmF3 or N3 1.0 slpm or nlpmF4 or N4 5. 0 slpm or nlpm

NOTE: Minimum flow is zero. You must specify full scale. Must fall within listed range.

F5 or N5 10 slpm or nlpmF6 or N6 20 slpm or nlpmF7 or N7 50 slpm or nlpmSCR Consult Factory

V4 4 to 20 mA linear output signal and setpointV6 RS-485 addressable (no analog output)

LT Leak Test Certificate PT Pressure test Certificate

NOTE: Power supplies are not

Included. See accessories to order.

50 B.1 6/106/10

/10/10

6

Email your questions or request for quote to

Regd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet Moulali Hyderabad – 500 040

A.P.India Tel: +91-040-27790886 / 9030299892

Email: [email protected] / www.masinstruments.com

Page 8: Regd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet · PDF fileRegd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet Moulali Hyderabad – 500 040 A.P.India Tel: +91-040-27790886

- Advanced Clamp-on Transit-time Technology for Accurate Flow Measurement

Features and Benefits: • High accuracy, ±1% of velocity • NIST Standard • Non-intrusive, clamp-on installation, easy

and fast. No pipe disturbance, no pressure drop, no moving parts

• Light weight (1.2lbs/538g for the handset). Compact design

• Bi-directional, wide range, -52ft/s ~ 52ft/s (-16m/s ~ 16m/s)

• Wide pipe size range, 3/4" ~ 240" (DN20 ~ DN6,000mm)

• Suitable for all commonly used pipe materials and liquids.

• Rechargeable battery for 10 hours of operation.

• Built-in data logger. • Totalizer for net, positive and negative

flow • Self-explanatory user interface.

Very easy to operate. • Optional StufManagerTM PC

software for data download and real-time data display. • Signal quality tracking and self-adjusting capabilities automatically match transducer

to pipe material • Can also be deployed as a remote RTU for long-term flow monitoring application • Ideal for flow survey, HVAC, flowmeter verification and all other applications where both

accuracy and portability are essential.

The STUF-200H Handheld Ultrasonic Flowmeter is one of the most powerful f lowmeters avai lable for l iquid measurement . The ut i l izat ion of our propr ietary u l trasonic s ignal processing, t ransi t- t ime measurement and s ignal qual i ty tracking technologies a l lows the f lowmeter to measure l iquid f low rate from outs ide of a pipe re l iably and accurately.

The STUF-200H flowmeter is careful ly

designed so that i t i s very compact and easy to use. A user can use one hand to hold as wel l as to operate the f lowmeter main uni t . The user-in terface is self-explanatory and very easy to fo l low. Besides , the unique clamp-on f ix ture design makes the instal la t ion very s imple and no special ski l ls or tools required. Due to the non- intrusive nature of the clamp-on technique, there is no pressure drop, no moving par ts , no leaks and no contaminat ion.

HANDHELD ULTRASONIC FLOWMETER Model: STTUF: 200

Page 9: Regd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet · PDF fileRegd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet Moulali Hyderabad – 500 040 A.P.India Tel: +91-040-27790886

Applications: The STUF-200H flowmeter is ideal for f low surveys and closed-pipe appl icat ions where non- invasive measurement of l iquids is required. Benef i ted f rom our advanced digi ta l s ignal processing technology, the handheld f lowmeter works re l iably in both clean and opaque l iquid f low. Examples of appl icat ions include:

• Water , including hot water , chi l led water , c i ty water , sea water , e tc . • Sewage and drainage water with small par t ic le quant i ty . • Oil, including crude oi l , lubr icat ing oi l , d iesel o i l , fuel o i l , e tc . • Chemicals , including alcohol, acids, e tc . • Solvents . • Beverage and food processors . • HVAC hot and cool water ,

water /g lycol solut ions. • Water and waste treatment . • Power plants (nuclear power p lants ,

thermal & hydropower p lants) , heat energy boi ler feed water

• Energy consumption supervis ion and water conservat ion management

• Metal lurgy and mining appl icat ions (e.g. , acid recovery)

• Marine operat ion and maintenance • Pulp and paper • Pipel ine leak detect ion, inspect ion,

t racking and col lect ion • Energy measurement and balancing • Water d is tr ibut ion network

monitor ing

Specifications:

Linearity Better than 1%

Repeatability 0.5%

Accuracy ±1% of velocity reading or ±10mm/s, whichever is bigger For small pipe (≤1”), the accuracy may vary

Response Time 0-999 seconds, user-configurable

Velocity -52ft/s ~ +52ft/s (-16m/s ~ +16m/s), bi-directional

Pipe Size 3/4" ~ 240" (DN20mm ~ DN6,000mm)

Pipe Material All metals, most plastics, lined pipe

Units English (U.S.) or metric

Totalizer Three 7-digit totalizers for totalizing net, positive and negative flows

Liquid Types Virtually all liquids (full pipe)

Liquid Temp 32˚ F ~ 212˚ F (0˚C ~ 100˚C) or 32˚ F ~ 312˚ F (0˚C ~ 155˚C), depending on transducer type

Security Setup Modification Lockout. Access code needed for unlocking

Handset

Clamp Fixture

RS232 Cable

S-type Xducer

Tape Ruler

Charger

Xduer Cable

Carrying Case

Page 10: Regd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet · PDF fileRegd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet Moulali Hyderabad – 500 040 A.P.India Tel: +91-040-27790886

Display 4x16 letters

Digital Interface OCT digital output, can be configured as frequency or pulse output RS-232C: serial communication port with simplified flowmeter protocol

StufManagerTM (optional): Windows PC software for data download and real-time data acquisition

Transducers Model M1 for standard, other 3 models for optional Refer to Optional Transducers section for more details

Transducer Cord Standard 2x15' (2x5m). Extension cable available upon request

Power Supply 3 AAA Ni-H built-in batteries. When fully recharged, it will last over 10 hours of operation 100V-240VAC for the charger

Data Logger Built-in data logger can store over 2,000 lines of data

Housing Material Aluminum alloy protective case. Suitable for normal and harsh environment

Case Size 7.9"x3.6"x1.3" (200mmx92mmx32mm)

Handset Weight 1.2 lbs (538g) with batteries

How does the STUF-200H flowmeter work?

The STUF-200H flowmeter is based on transi t-t ime measurement pr inciple, as shown in the fo l lowing f igure.

A typical t ransi t- t ime f low measurement system ut i l izes two transducers (A and B) that funct ion as both ul trasonic transmit ter and receiver . The t ransducers are c lamped on the outside of a c losed pipe a t a specif ic dis tance f rom each other . The f low meter operates by al ternately transmit t ing and receiving a coded burst of sound energy between the two transducers and measur ing the t ransi t t ime that i t takes for sound to travel between the two transducers. The difference in the transi t t ime measured is d irect ly and exact ly re la ted to the veloci ty of the l iquid in the p ipe.

The t ransducers can be mounted in three methods, Z-method, V-method and W-method, depending on pipe s ize. Z-method is used for large pipe. The two transducers are instal led on opposi te s ides of the p ipe. V-method is used for medium size p ipe. The two transducers are on the same side, thus, the sound transverses the f low twice. W-method is usual ly used for small p ipe. The sound transverses across the f low four t imes.

Z-method

V-method

W-method

Page 11: Regd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet · PDF fileRegd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet Moulali Hyderabad – 500 040 A.P.India Tel: +91-040-27790886

Optional Transducers:

Type HS Handheld small size transducer (magnetic with mounting rack and handle) Dim 7.9”x1”x1” (200x25x25mm3), handle length 3.9” (100mm) For pipe size: 3/4” ~ 4” (DN20 ~ DN100mm) Temperature: 32˚ F ~ 212˚ F (0˚C ~ 100˚C)

Type S1HT Small size, high temperature transducer Pipe size: 1” ~ 4” (DN25 ~ DN100mm) Temperature: 32˚ F ~ 312˚ F (0˚C ~ 155˚C)

Type HM Medium size transducer (magnetic with mounting rack) Dim 11”x1.6” x1.6” (280x40x40mm3) for each Pipe size: 2” ~ 28” (DN50 ~ DN700mm) Temperature: 32˚ F ~ 212˚ F (0˚C ~ 100˚C)

Type M1 Standard medium size transducer (magnetic with clamp-on fixture) Dim 2.4”x1.8” x1.8” (60x45x45mm3) Pipe size: 2” ~ 28” (DN50 ~ DN700mm) Temperature: 32˚ F ~ 212˚ F (0˚C ~ 100˚C)

Type M1HT Medium size, high temperature transducer Pipe size: 2” ~ 28” (DN50 ~ DN700mm) Temperature: 32˚ F ~ 312˚ F (0˚C ~ 155˚C)

Type L1 Large size transducer (magnetic with clamp-on fixture) Dim 3.1”x2.7” x2.2” (80x70x55mm3) Pipe size: 11” ~ 240” (DN300 ~ DN6,000mm) Temperature: 32˚ F ~ 212˚ F (0˚C ~ 100˚C)

Model Selection:

S T U F - 2 0 0 H - - -

Example:

STUF-200H-M1-1: handheld ultrasonic flowmeter with standard M1 type transducer plus PC software.

. All rights reserved.

HS – Handheld type for pipe 3/4” ~ 4” S1HT – High-temp type for pipe 1” ~ 4” HM – Mounting-rail type for pipe 2” – 28” M1 – Standard type for pipe 2” – 28” M1HT – High-temp type for pipe 2” ~ 28” L1 – Standard type for pipe 11” – 240”

PC Software 0 – No 1 – Yes

Y-Cable 0 – No 1 – Yes

Regd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet Moulali Hyderabad – 500 040 A.P.India

Tel: +91-040-27790886 / 39188320 / 9030299892 Email: [email protected] www.masinstruments.com