Reference Codes - Switchgear2

Power Contactors

C W M 1 2 - 1 0 - 3 0 - V 4 0

Model

CWMC

CWC0

CWCI0

CWCH0

CWM

CWB

Terminal type Code

Screw Blank

For printedcircuit board

I

Spring S

Main contacts Code

2NO 20

3NO 30

4NO 40

2NC 02

2NO+2NC 22

Coil voltage Code

24 V 50/60 Hz D02

220 V 50/60 Hz D23

24 V dc C03

220 V dc C15

Complete table at pages 21 and 22

Auxiliary contacts Code

1NO 10

1NC 01

1NO+1NC 11

1NO+3NC 13

2NO+2NC 22

3NO+1NC 31

4NO 40

4NC 04

4NO+4NC 44

None 00

Rated currentIn (AC-3)

Code

7 A 7

9 A 9

12 A 12

16 A 16

18 A 18

25 A 25

32 A 32

38 A 38

40 A 40

50 A 50

65 A 65

80 A 80

95 A 95

105 A 105

112 A 112

150 A 150

180 A 180

250 A 250

300 A 300

400 A 400

500 A 500

630 A 630

800 A 800

Page 3: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

www.weg.net

Reference Codes - Switchgear 3

Control Relays

Model

CWCA0

C W C A 0 - 2 2 - 0 0 - V 4 0

Terminal type Code

Screw Blank

For printedcircuit board

I

Spring S

Auxiliary contacts1) Code

1NO+1NC 11

1NO+3NC 13

2NO+2NC 22

3NO+1NC 31

4NO 40

4NC 04

4NO+4NC 44

5NO+3NC 53

6NO+2NC 62

7NO+1NC 71

8NO 80

8NC 08

Coil voltage Code

24 V 50/60 Hz D02

220 V 50/60 Hz D23

24 V dc C03

220 V dc C15

Complete table at pages 21 and 22

Note: 1) Configurations with more than 4 auxiliary contacts can be achieved only by adding auxiliary contact blocks.

Page 4: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

www.weg.net

Reference Codes - Switchgear4

Overload Relays

Solid-State Relays

Model

RW17

RW27

RW67

RW117

RW317

RW407

R W 1 1 7 - 2 D 3 - U 0 8 0

Connector links

1 D

2 D

Poles

2

3

Rated current (A) Code

0.28-0.4 D004

0.4-0.63 C063

0.56-0.8 D008

0.8-1.2 D012

1.2-1.8 D018

1.8-2.8 D028

2.8-4 U004

4-6.3 D063

5.6-8 U008

7-10 U010

8-12.5 D125

10-15 U015

11-17 U017

15-23 U023

22-32 U032

Rated current (A) Code

32-40 U040

25-40 U040

32-50 U050

40-57 U057

50-63 U063

57-70 U070

63-80 U080

75-97 U097

90-112 U112

100-150 U150

140-215 U215

200-310 U310

275-420 U420

400-600 U600

560-840 U840

Model

RWB40

RWM40

RWM112

RWM420

RWM840

R W B 4 0 - 3 - A 4 U 0 4 0

Rated current (A) Code

0.4-2 U002

1.6-8 U008

5-25 U025

8-40 U040

14-56 U056

28-112 U112

50-250 U250

85-420 U420

170-840 U840

Bimetallic Relays

Page 5: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

www.weg.net

Reference Codes - Switchgear 5

Smart Relay - Control Unit

Motor Protective Circuit Breaker

Model

MPW12

MPW18

MPW40

MPW80

MPW100

M P W 4 0 i - 3 - D 0 6 3

S R W 0 1 - U C P T 1 E 4 7

Terminal type Code

Screw Blank

Spring1) S

Communication protocol

Code

No communication B

DeviceNet D

Modbus-RTU M

Profibus-DP P

Protection Code

PTC T

Earth leakage E

Digital input operating voltage

Code

24 V dc 1

110 V ac 2

Supply voltage Code

24 V ac (50-60 Hz) / V dc E26

110-240 V ac (50-60 Hz) / V dc E47

Type of protection Code

Thermomagnetic (Imx13) Blank

Magnetic only (Imx13) i

Thermomagnetic (Imx19) t

Rated current (A) Current (A) Code

0.1-0.16 0.16 C016

0.16-0.25 0.25 C025

0.25-0.4 0.4 D004

0.4-0.63 0.63 C063

0.63-1 1 U001

1-1.6 1.6 D016

1.6-2.5 2.5 D025

2.5-4 4 U004

4-6.3 6.3 D063

6.3-10 10 U010

8-12 12 U012

10-16 16 U016

16-20 20 U020

20-25 25 U025

25-32 32 U032

32-40 40 U040

40-50 50 U050

50-65 65 U065

55-75 75 U075

65-80 80 U080

70-90 90 U090

80-100 100 U100

Note: 1) Spring terminal available only for MPW12 (up to 12 A).

Page 6: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

www.weg.net

Reference Codes - Switchgear6

Pushbuttons - CSW Pushbuttons and Pilot Lights

Line Code

Standard CSW

New line CSW2

C S W - B F 2

Color Code

White/translucid 0

Red 1

Green 2

Yellow 3

Blue 4

Black 5

Orange 6

N/A (CSW-BES) Blank

Type Code

Pushbutton B

Flange Code

No flange WH

Flange AF3 (old version) Blank

Front typeAvailable for line

Code

Mushroom

CSW

C

Illuminated mushroom CI

Illuminated extended SI

Double (CSW) D

Emergency with key EY

Emergency (CSW) EG

Illuminated flush FI

Extended S

Flush (CSW) F

Guarded GA

Emergency stop - pull to release ESP

Emergency stop - turn to release ESG

Emergency stop - key to release ESY

Emergency stop with green position indicator - pull to release

ESPS

Emergency stop with green position indicator - turn to release

ESGS

Emergency stop with green position indicator - key to release

ESYS

Mushroom with latch - turn to release CT

Mushroom with latch - key to release CY

Flush double

CSW2

DF

Extended double DS

Illuminated flush double1) DFI

Illuminated extended double1) DSI

Flush triple1) TF

Extended triple TS

Page 7: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

www.weg.net

Reference Codes - Switchgear 7

Selector Switches - CSW Pushbuttons and Pilot Lights

Line Code

Default CSW

C S W - C K 3 F 4 5 W H

Type Code

Selector switch C

Front type Code

Lever A

With key Y

Illuminated knob KI

Knob K

Release Code

Return R

Return right RD

Return left RE

Fixed F

Voltage Code

White/translucid 0

Red 1

Green 2

Yellow 3

Blue 4

Black (default CSW-CK) Blank

N/A (Key) Blank

Angle Code

45° 45

90° 90

Pilot Lights - CSW Pushbuttons and Pilot Lights

Line Code

Default CSW

C S W - S D 1 F 3 F V

Color Code

White/translucid 0

Red 1

Green 2

Yellow 3

Blue 4

Black 5

Orange 6

Frontal Code

CSW SD

Line Voltage Code

CSW

12 V ac/dc E25

24 V ac/dc E26

48 V ac/dc E27

110-130 V 50/60 Hz D61

220-240 V 50/60 Hz D66

125 V dc C13

Flange Code

New flange 3VF

Old version Blank

Flange Code

New flange F

Old version Blank

Positions

3

2

Flange Code

No flange WH

Flange AF3 (old version) Blank

Page 8: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

www.weg.net

Reference Codes - Switchgear8

Common Sets - CSW Pushbuttons and Pilot Lights

Line Code

Default CSW

New line CSW2

Tipo Code

Pushbutton B

Selector switch C

Signalling light S

Position Code

Return R

Return right RD

Return left RE

Fixed F

N/A Blank

Positions Code

3 3

2 2

N/A Blank

Only for selector switches Only for selector switches

Only for selector switches

Angle Code

45° 45

90° 90

Available for type

Front typeAvailable for line

Code

Signalling light

Diffused

CSW

D

Selector switch

Lever A

With key Y

Illuminated knob KI

Knob K

Pushbutton

Mushroom C

Illuminated mushroom CI

Illuminated extended SI

Double D

Emergency stop key to release

ESY

Emergency stop turn to reset (CSW)

ESG

Emergency stop pull to release (CSW)

ESP

Emergency stop with green position indicator - pull to release

ESPS

Emergency stop with green position indicator - turn to release

ESGS

Emergency stop with green position indicator - key to release

ESYS

Illuminated flush FI

Extended S

Flush F

Guarded GA

Flush double

CSW2

DF

Extended double DS

Illuminated flush double1) DFI

Illuminated extended double1) DSI

Flush triple1) TF

Extended triple TS

C S W - B F I 2 - 0 0 2 0 0 0 0 0 F D 6 6 3 F V

Page 9: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

www.weg.net

Reference Codes - Switchgear 9

C S W - B F I 2 - 0 0 2 0 0 0 0 0 F D 6 6 3 F V

Qty of blocks2NO (BC20)

1

2

3

4

5

0

Qty of blocks1NC late break (BCR01)

1

2

3

4

5

0

Qty of blocks1NO (BC10)

1

2

3

4

5

0

Qty of blocks2NC (BC02)

1

2

3

4

5

0

Qty of blocks1NO+1NC (BC11)

1

2

3

4

5

0

Qty of blocks1NC (BC01)

1

2

3

4

5

0

Qty of blocks1NO early make (BCA10)

1

2

3

4

5

0

Color Code

White/translucid 0

Red 1

Green 2

Yellow 3

Blue 4

Black 5

Orange 6

Qty of blocks1NC (BCM01)

1

2

3

0

Voltage Code

12 V dc 50/60 Hz E25

24 V dc 50/60 Hz E26

48 V dc 50/60 Hz E27

110-130 V dc 50/60 Hz D61

110-130 V dc C40

110 V 50/60 Hz D13

125 V dc C13

220 V 50/60 Hz D23

220-240 V 50/60 Hz D66

Flange Code

New flange F

Old version Blank

Flange Code

New flange 3VF

Old version Blank

Page 10: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

www.weg.net

Reference Codes - Switchgear10

Coil voltage Code

230 V 50/60 Hz D24

400 V 50/60 Hz D34

Complete table at pages 21 and 22

Enclosed Direct On Line Starter

Model

DLW

DLWM

ESW

ESWS

D L W - 0 7 D 2 4 P 6 5 - R 2 3

ContactorAC-3 current

Contactor model Code

7 ACW07 7

CWC07 07

9 ACWM9 9

CWC09 09

12 ACWM12 12

CWC012 012

16 A CWC016 016

18 A CWM18 18

25 A CWM25 25

32 A CWM32 32

40 A CWM40 40

50 A CWM50 50

65 A CWM65 65

Overload relay Code

RW17-1D3-C063 R02

RW17-1D3-D008 R03

Complete table at page 23

Pilot device type CodeAvailable for model

Manual-Off-Auto Switch B

DLW / DLWM

Reset I

Start + Stop/Reset P

Stop/Reset D

No pushbutton E ESW / ESWSStart-Stop pushbutton A

Protection degree Code

IP65 (DLW) 65

IP52 (DLW) None

Type 4X (ESW/ESWS) X

Page 11: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

www.weg.net

Reference Codes - Switchgear 11

Electronic Timing Relays

Type Code

Single function RTW

Multifunction ERWT

Auxiliary contacts

Type Code

1 NOC4) 01

2 NOC 02

Timing selection

Time range Code

0.1 - 1s5) U001S

0.3 - 3s U003S

1 - 10s U010S

3 - 30s U030S

6 - 60s U060S

10 - 100s U100S

30 - 300s U300S

1 - 10min6) U010M

3 - 30min6) U030M

0.1s - 10min7) MAT

0.2s - 150h7) MBT

0.1s - 10 days8) MT1

Function Code

ON delay RE

Pulse ON PE

Pulse flasher - start ON1) CI

Pulse flasher - start OFF1) CIR

Symmetric flasher - start ON CIL

Symmetric flasher - start OFF CID

OFF-delay RD

OFF-delay no control1) RDI

Star-delta2) ET

8 selectable functions3) MF1

ON-delay (A)

OFF-delay with control signal (Ba)

ON- and OFF-delay with control signal (Ca)

Symmetrical flasher, starts with pulse on (Da)

Symmetrical flasher, starts with pulse off (Db)

Interval (E)

Retriggerable interval with control signal off (Fa)

Star-Delta (G)

8 selectable functions3) MF2

ON and OFF delay with control signal (Cb)

Asymetrical flasher, starts with pulse OFF (Dd)

Percentage flasher, starts with pulse OFF (Df)

Delayed adjustable-length pulse (Ia)

Asymmetrical flasher, starts with pulse ON (Dc)

Percentage flasher, starts with pulse ON (De)

Flasher to reversing motor (Dg)

Bistable (J)

Supply voltage

Alternating current (50/60 Hz) / Direct current

DescriptionApplicable to the following

RTW modelsCode

24 V ac / 24 V dc RE, PE, CI, CIR, CIL, CID, ET E26

48 V ac / 24 V dc RE, PE, CI, CIR, CIL, CID, ET E33

110-130 V ac / 24 V dc RE, PE, CI, CIR, CIL, CID, ET E37

220-240 V ac / 24 V dc RE, PE, CI, CIR, CIL, CID, ET E40

24-240 V ac / 24-240 V dc RE, PE, CI, CIR, CIL, CID, ET, RD, RDI E059)

Alternating current (50/60 Hz)

DescriptionApplicable to the following

RTW models10) Code

24 V ac RD D02

48 V ac RD D07

110-130 V ac RD D61

220-240 V ac RD D66

380-440 V ac RE, PE, ET D71

Direct current

DescriptionApplicable to the following

RTW modelsCode

24 V dc RD C03

Notas:1) Not available for multi-timing models (RTW-M);2) RTW-ET is available only with two timing options: 3 - 30s (code U030S) and 0.1s - 10min (code MAT);3) MF1 and MF2 functions available only on multifunction models ERWT;4) Not available for star-delta models (RTW-ET) and multifunction models (ERWT-MF1, MF2);5) Timing range 0.1 - 1s (code U001S) is not available for Models RTW-CI, CIR, RD and RDI;6) Timing ranges 60 - 600s (code U010M) and 3 - 30min (code U030M) are available only for model RTW-RDI;7) Timing ranges 0.1s - 10min (code MAT) and 0.2s - 150h (code MBT) are available only for models RTW-RE, PE, RD, CIL, CID and ET;8) Timing range 0.1s - 10 days (code MT1) is available only for multi function models ERWT-MF1 and MF2;9) E05 supply voltage available for:

Single timing models: RTW-CI, CIR e RDI Multi timing models (MAT / MBT): RE, PE, CI, CIL, CIR, CID, RD e ET Multi function models: MF1 and MF2;

10) Available only for single-timing models.

E R W T - M F 1 - 0 2 - M T 1 - E 0 5

Page 12: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

www.weg.net

Reference Codes - Switchgear12

Electronic Monitoring Relays

Phase Loss Protector

Supply voltage Code

220-240 V 50/60 Hz D66

380-415 V 50/60 Hz D70

440-480 V 50/60 Hz D74

Phase loss

Phase Loss and Phase Sequence Protector

Supply voltage Code

220-240 V 50/60 Hz D66

380-415 V 50/60 Hz D70

440-480 V 50/60 Hz D74

Phase loss and phase sequence

Undervoltage and Overvoltage Protector

Supply voltage Code

208 V 50/60 Hz D77

220 V 50/60 Hz D23

230 V 50/60 Hz D24

240 V 50/60 Hz D25

380 V 50/60 Hz D33

Supply voltage Code

400 V 50/60 Hz D34

415 V 50/60 Hz D35

440 V 50/60 Hz D36

460 V 50/60 Hz D38

480 V 50/60 Hz D39

Undervoltage and overvoltage

Power supply system

Blank Three phase

M Single phase

Supply voltage Code

220-240 V 50/60 Hz D66

380-415 V 50/60 Hz D70

440-480 V 50/60 Hz D74

Phase sequence

Phase Sequence Protector

R P W - F F - D 7 0

R P W - S F - D 7 0

R P W - F S F - D 7 0

R P W - S S M D 2 3

Page 13: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

www.weg.net

Reference Codes - Switchgear 13

Temperature Monitoring with PTC

Supply voltage Code

24-240 V ac / V dc E05

Supply voltage Code

220-440 V ac D90

Type of monitoring and protection Code

Phase loss (PF)Overvoltage (>Un)

Phase unbalance (Asy)Phase sequence (PS)Undervoltage (<Un)

Neutral detection (ND)

VM1

Phase loss (PF)Overvoltage (>Un)

Phase unbalance (Asy)Undervoltage (<Un)

Neutral detection (ND)

VM2

PTC protection

Multifunction Three-Phase Monitoring Relays

Electronic Level Control Relay

Supply voltage Code

100-240 V ac / V dc E09

Type of control Code

Filling EN

Draining ES

Electronic Monitoring Relays

R P W - P T C - E 0 5

R N W - E N - E 0 9

E R W M - V M 1 - 0 1 - D 9 0

Page 14: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

www.weg.net

Reference Codes - Switchgear14

Miniature Circuit Breakers

MDW / MDWH

Rated current (in) Code

6 A 6

10 A 10

16 A 16

20 A 20

25 A 25

32 A 32

40 A 40

50 A 50

63 A 63

MDW

Rated current (in) Code

70 A 70

80 A 80

100 A 100

125 A 125

Tripping curve Code

B B

C C

M D W H 3 - 1 0 0 - 2

Model

MDW

MDWH

Poles

1

2

3

4

Miniature Switch Disconnectors

Rated current (in) Code

40 A 40

63 A 63

80 A 80

100 A 100

S I W - 1 0 0 - 2

Poles

2

3

4

Residual Current Circuit Breakers (Earth Leakage Switches)

Sensibility Code

30 mA 30

300 mA 300

Rated current (in) Code

25 A 25

40 A 40

63 A 63

80 A 80

100 A 100

R D W 3 0 0 - 1 0 0 - 2

Referência

RDW

Poles

2

4

Page 15: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

www.weg.net

Reference Codes - Switchgear 15

D W A 8 0 0 H - E 3 2 0 - 3 - 1 6 6 - 2 1 - E 15 - D 6 6

D W B 1 6 0 N 2 5 - 3 D F

DWB Line

Molded Case Circuit Breakers

DWA Line

Type of protection

Code

Distribution DWA

Motor protection DWM

Generator protection

DWG

Without prot.(switch)

IWATrip unit Code

Electronic LSI (default for DWA1600)

E

Thermomagnetic (default for DWA800) Blank

Breaking capacity at 380-415 V ac Code

30/35 kA N

50 kA S

65 kA H

Poles

22)

3

42)

Auxiliary contacts BC/AL Code

AL 01

BC1 10

BC1+AL 11

BC2 20

BC2+AL 21

BC3 30

None 0

Operating handle Code

MR (short) DWA800-1600 166

MR (long) DWA800-1600 465

MRI MRI

None 0

Shunt release Code

24 V ac / V dc E26

48 V ac / V dc E27

60 V ac / V dc E28

110-130 V ac / V dc E10

220-250 V ac / V dc E15

None 0

Undervoltage release Code

24 V dc C03

48 V dc C07

125 V dc C13

110-127 V ac D60

200-250 V ac D66

380-415 V ac D70

None 0

Frame

800

1,600

Rated current

320

400

420

500

630

700

800

1,250

1,600

Notes: 1) For IWB switches, please disconsider “Breaking capacity” and “Type of protection”. 2) 2 and 4-pole versions under request. 3) DWB400 only.

Model

DWB160

DWB250

DWB400

IWB1601)

IWB2501)

IWB4001)

Rated current (A)

16 90

20 95

25 100

32 105

40 110

50 125

55 140

Ratedcurrent (A)

63 150

65 160

70 185

75 200

80 250

85 320

400

Breaking capacity at 380-415 V ac Code

16 kA B

30/35 kA N

65 kA H3)

80 kA L

Poles

22)

3

4

Type of protection

Trip settings Code

Distribution

Fixed thermal and magnetic release DX

Adjustable thermal and fixed magnetic release DF

Adjustable thermal and magnetic release DA

Motor protectionFixed magnetic release MF

Adjustable magnetic release MA

Generator protection

Fixed thermal and magnetic release GX

Adjustable thermal and fixed magnetic release GF

TAdjustable thermal and magnetic releases GA

Page 16: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

www.weg.net

Reference Codes - Switchgear16

A C W 1 0 0 H - F M U 2 0 - 3

Type of protection Code

Adjustable thermal and fixed magnetic release FMU

Adjustable thermal and magnetic releases ATU

Electronic LSI ETS

Magnetic only - motor protection MTU

Breaking capacity Code

High capacityH

U (ACW800)

Very high capacity2) V

Rated current (A)

20

25

32

40

50

63

80

Rated current (A)

100

125

160

200

400

630

800

Model

ACW100

ACW1011)

ACW160

ACW1611)

ACW250

ACW400

ACW630

ACW800

Poles

3

ACW Line

Molded Case Circuit Breakers

Notes: 1) MTU protection only. 2) Up to ACW630.

Page 17: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

www.weg.net

Reference Codes - Switchgear 17

Switch-Disconnectors

Compact Switch-Disconnectors with Red-Yellow Handle1)

Fuse Switch-Disconnectors

M S W 1 0 0 P - 3 H

F S W 1 0 0 - 3 H

Rated current (A)

12

16

20

25

40

63

80

100

125

160

Rated current (A)

100

160

250

400

630

1,250

Poles

3

2

Mounting Code

Base B

Door P

Handle Code

With handle H

Without handle Blank

Model Code

Fuse-switch-disconnectors FSW

Handle Code

With handle H

Note: 1) Black-gray handle available upon request.

Page 18: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

www.weg.net

Reference Codes - Switchgear18

Fuses

gL/gG Fuses - D and NH (Blade Contact) Types

Fuse type Code

D type FDW

NH type FNH

Breaking capacity Fuse type Code

120 kA NH type U

50 kA D type S

Rated current (A)

2

4

6

10

16

20

25

35

50

63

80

100

Rated current (A)

125

160

200

224

250

300

315

355

400

425

500

630

F N H 2 - 6 3 0 U

Size for NH fuses1)

000

00

1

2

3

Size Code

00 00

1 1

2 2

3 3

2X3 (FEA) 23

Type Code

aR A

Breaking capacity

Code

200 kA Y

100 kA K

Constructive characteristics Code

Metric flush end(terminal with metric thread)

FEM

Metric flush end2X3 with busbar in one side

FEA

Blade contact Blank

High Speed - aR Type - Fuses NH

F N H 3 F E M - 1 0 0 0 Y - A

Rated current (A)

20

25

35

40

50

63

80

100

125

160

200

250

315

350

400

Rated current (A)

450

500

550

630

700

710

800

900

1,000

1,100

1,250

1,400

1,600

1,800

2,000

Note: 1) For D type fuses keep it blank.

Page 19: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

www.weg.net

Reference Codes - Switchgear 19

Capacitors for Power Factor Correction

U C W 2.5 V25 L10

Valid only for models UCW and UCWT

Capacitor type Code

Single-phase unit UCW

3-phase unit UCWT

3-phase module MCW

DimensionsØ x H (mm)

Code

53x68 J2

53x85 J4

53x105 J6

53x141 J8

60x105 L6

60x156 L10

60x211 L16

DimensionsØ x H (mm)

Code

70x156 M10

75x205 N12

75x225 N20

75x285 N22

100x230 Q26

116x230 S26

116x290 S28

Rated voltage Code

220 V 60 Hz V25

380 V 60 Hz V40

440 V 60 Hz V49

480 V 60 Hz V53

535 V 60 Hz V57

Reactive power (kvar)1)

2.5

5

7.5

10

12.5

15

17.5

Reactive power (kvar)1)

20

22.5

25

27.5

30

35

Note: 1) When selecting the reactive power (kvar) it is important to keep in mind the network frequency and voltage. For further information check the Power Factor Correction catalogue at www.weg.net.

Page 20: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

www.weg.net

Reference Codes - Switchgear20

Air Circuit Breakers

Maximum rated

currentCode

800 A 08

1,600 A 16

2,000 A 20

2,500 A 25

3,200 A 32

4,000 A 40

5,000 A 50

6,300 A 63

Rated current

Code

800 A 08

1,600 A 16

2,000 A 20

2,500 A 25

3,200 A 32

4,000 A 40

5,000 A 50

6,300 A 63

Motorized operator

Code

None (default) 0

100~130 V ac/dc 1

200~250 V ac/dc 2

24~30 V dc 3

48~60 V dc 4

380 V ac 5

480 V ac 6

Accessories CodeNone (default) Blank

ON/OFF button lock B Key lock for 1 ACB K

Key interlock for 3 ACBs K2 Mechanial interlock (2 breakers) M Mechanical interlock (3 breakers) M3

Door interlock D

B+K BK

B+K2 B2 B+M BM B+D BD K+M KM K+D KD

Profibus communication1) CP Modbus communication1) CM

Undervoltage release CodeNone (default) 0

100~130 V ac/dc 1200~250 V ac/dc 2

24~30 V dc 348~60 V dc 4

380~480 V ac 5200~250 V ac/dc with delay 6100~130 V ac/dc with delay 7

48~60 V dc with delay 8380~480 V ac with delay 9

Opening coil Code200~250 V ac/dc (default) 2

No coil 0100~130 V ac/dc 1

24~30 V dc 348~60 V dc 4

380~480 V ac 5

Closing coil Code200~250 V ac/dc (default) 2

No coil 0100~130 V ac/dc 1

24~30 V dc 348~60 V dc 4

380~480 V dc 5

Version Code

Fixed F

Withdrawable E

Frame size Code

For 1,600 A DN

For 2,000~3,200 A ES

For 4,000~5,000 A FS

For 6,300 A GS

Poles

3

4

Auxiliary contacts Code

5NO+5NC (default) A

Position auxiliary contacts(for withdrawable version)

B

Protection and measurement unit2) Code

LSIG + A3) (100~250 V ac/dc, 60 Hz) - default AZ1

No protection unit 000

LSI + A3) (100~250 V ac/dc, 60 Hz) + Earth leakage5) AF1

LSI + A3) (100~250 V ac/dc, 50 Hz) + Earth leakage5) AF6

LSIG + A3) + Communication (100~250 V ac/dc, 60 Hz) AC1

LSIG + A3) + Communication (100~250 V ac/dc, 50 Hz) AC6

LSIG + A3) + Communication 24~60 V dc AC2

LSIG + M4) + Communication (100~250 V ac/dc, 60 Hz) PC1

LSIG + M4) + Communication (100~250 V ac/dc, 50 Hz) PC6

LSIG + V + A3) + Communication 24~60 V dc PC2

LSIG + A3) 24~60 V dc AZ2

LSIG + A3) (100~250 V ac/dc, 50 Hz) AZ6

Accessories supplied as standard for the entire range

Auxiliary contacts (5NO+5NC)

Alarm contacts

Opening coil 200-250 V ac/dc

Closing coil 200-250 V ac/dc

Operation counter

Position locking with padlock (padlock not included) - withdrawable version only

Position indicator (inserted /test/ withdrawn) - withdrawable version only

A B W 1 6 D N 3 - 1 6 A Z 1 F - A 0 2 2 0

Notes: 1) To be used with circuit breakers that have protection units type AC or PC. 2) For further information about protection units, check the catalogue at WEG website. 3) A - Current measurement. 4) M - Current, voltage, power and frequency measurements. 5) The current transformer ABW-ZCT must be used for earth leakage protection (supplied as accessory).

Page 21: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

www.weg.net

Reference Codes - Switchgear 21

Supply voltage Code

10 V 50 Hz / 12 V 60 Hz V01

12 V 50 Hz / 14 V 60 Hz V02

16 V 50 Hz / 20 V 60 Hz V03

20 V 50 Hz / 24 V 60 Hz V04

24 V 60 Hz V05

24 V 50 Hz / 28 V 60 Hz V06

28 V 50 Hz / 32 V 60 Hz V07

32 V 50 Hz / 36 V 60 Hz V08

36 V 50 Hz / 42 V 60 Hz V09

42 V 50 Hz / 48 V 60 Hz V10

48 V 50 Hz / 56 V 60 Hz V11

52 V 50 Hz / 60 V 60 Hz V12

75 V 60 Hz V13

70 V 50 Hz / 80 V 60 Hz V14

95 V 50 Hz / 110 V 60 Hz V15

110 V 60 Hz V16

100 V 50 Hz / 115 V 60 Hz V17

110 V 50 Hz / 120 V 60 Hz V18

110-115 V 50 Hz / 127 V 60 Hz V19

120 V 50 Hz / 140 V 60 Hz V20

127 V 50 Hz / 150 V 60 Hz V21

139 V 50 Hz /160 V 60 Hz V22

180 V 50 Hz / 208 V 60 Hz V23

180-208 V 50 Hz / 208-240 V 60 Hz V24

220 V 60 Hz V25

190 V 50 Hz / 220 V 60 Hz V26

230 V 60 Hz V27

200 V 50 Hz / 230 V 60 Hz V28

240 V 60 Hz V29

208 V 50 Hz / 240 V 60 Hz V30

220 V 50 Hz V31

220 V 50 Hz / 255 V 60 Hz V32

220-230 V 50 Hz / 240-260 V 60 Hz V33

230 V 50 Hz V34

250 V 50 Hz V35

230 V 50 Hz / 266 V 60 Hz V36

Supply voltage Code

12 V 50/60 Hz D01

24 V 50/60 Hz D02

28 V 50/60 Hz D03

32 V 50/60 Hz D04

36 V 50/60 Hz D05

42 V 50/60 Hz D06

48 V 50/60 Hz D07

56 V 50/60 Hz D08

60 V 50/60 Hz D09

72 V 50/60 Hz D10

80 V 50/60 Hz D11

100 V 50/60 Hz D12

110 V 50/60 Hz D13

115 V 50/60 Hz D14

120 V 50/60 Hz D15

125 V 50/60 Hz D16

127 V 50/60 Hz D17

130 V 50/60 Hz D18

140 V 50/60 Hz D19

150 V 50/60 Hz D20

190 V 50/60 Hz D21

200 V 50/60 Hz D22

220 V 50/60 Hz D23

230 V 50/60 Hz D24

240 V 50/60 Hz D25

250 V 50/60 Hz D26

255 V 50/60 Hz D27

265 V 50/60 Hz D28

270 V 50/60 Hz D29

330 V 50/60 Hz D30

350 V 50/60 Hz D31

370 V 50/60 Hz D32

380 V 50/60 Hz D33

400 V 50/60 Hz D34

415 V 50/60 Hz D35

440 V 50/60 Hz D36

450 V 50/60 Hz D37

460 V 50/60 Hz D38

480 V 50/60 Hz D39

Supply voltage Code

230-240 V 50 Hz / 277 V 60 Hz V37

250 V 60 Hz V38

310 V 60 Hz V39

380 V 60 Hz V40

325 V 50 Hz / 380 V 60 Hz V41

380 V 50 Hz / 440 V 60 Hz V42

380-400 V 50 Hz / 440-460 V 60 Hz V43

400 V 50 Hz V44

400 V 60 Hz V45

400 V 50 Hz / 460 V 60 Hz V46

400-415 V 50 Hz / 480 V 60 Hz V47

440 V 50 Hz V48

440 V 60 Hz V49

440 V 50 Hz / 510 V 60 Hz V50

460 V 50 Hz V51

480 V 50 Hz V52

480 V 60 Hz V53

500 V 50 Hz V54

500 V 60 Hz V55

500 V 50 Hz / 600 V 60 Hz V56

535 V 60 Hz V57

550 V 50 Hz V58

550 V 60 Hz V59

550 V 50 Hz / 660 V 60 Hz V60

575 V 60 Hz V61

660 V 60 Hz V62

600 V 50 Hz / 690 V 60 Hz V63

Voltage Codes - Controls

Alternating Current

Page 22: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

www.weg.net

Reference Codes - Switchgear22

Supply voltage Code

500 V 50/60 Hz D40

510 V 50/60 Hz D41

525 V 50/60 Hz D42

550 V 50/60 Hz D43

575 V 50/60 Hz D44

600 V 50/60 Hz D45

630 V 50/60 Hz D46

660 V 50/60 Hz D47

690 V 50/60 Hz D48

12-24 V 50/60 Hz D49

12-60 V 50/60 Hz D50

20-24 V 50/60 Hz D51

24-28 V 50/60 Hz D52

24-48 V 50/60 Hz D53

40-48 V 50/60 Hz D54

48-127 V 50/60 Hz D55

50-250 V 50/60 Hz D56

72-250 V 50/60 Hz D57

100-110 V 50/60 Hz D58

100-127 V 50/60 Hz D59

110-127 V 50/60 Hz D60

110-130 V 50/60 Hz D61

110-220 V 50/60 Hz D62

127-250 V 50/60 Hz D63

200-220 V 50/60 Hz D64

200-240 V 50/60 Hz D65

220-240 V 50/60 Hz D66

250-380 V 50/60 Hz D67

270-380 V 50/60 Hz D68

365-440 V 50/60 Hz D69

380-415 V 50/60 Hz D70

380-440 V 50/60 Hz D71

380-510 V 50/60 Hz D72

400-510 V 50/60 Hz D73

440-480 V 50/60 Hz D74

500-510 V 50/60 Hz D75

660-690 V 50/60 Hz D76

208 V 50/60 Hz D77

Supply voltage Code

5 V dc C01

12 V dc C02

24 V dc C03

28 V dc C04

36 V dc C05

42 V dc C06

48 V dc C07

55 V dc C08

60 V dc C09

72 V dc C10

80 V dc C11

110 V dc C12

125 V dc C13

130 V dc C14

220 V dc C15

230 V dc C16

250 V dc C17

400 V dc C18

415 V dc C19

440 V dc C20

500 V dc C21

600 V dc C22

1,000 V dc C23

1,200 V dc C24

6-240 V dc C31

6-250 V dc C32

12-600 V dc C33

24-28 V dc C34

24-48 V dc C35

24-240 V dc C36

42-50 V dc C37

48-260 V dc C38

100-125 V dc C39

110-130 V dc C40

120-127 V dc C41

130-250 V dc C42

200-240 V dc C43

208-240 V dc C44

208-250 V dc C45

230-240 V dc C46

150 V dc C47

42-48 V dc C97

110-125 V dc C98

220-250 V dc C99

Supply voltage Code

12-48 V dc 50/60 Hz E01

24-28 V dc 50/60 Hz E02

24-48 V dc 50/60 Hz E03

24-60 V dc 50/60 Hz E04

24-240 V dc 50/60 Hz E05

42-50 V dc 50/60 Hz E06

60-72 V dc 50/60 Hz E07

100-125 V dc 50/60 Hz E08

100-240 V dc 50/60 Hz E09

110-130 V dc 50/60 Hz E10

110-220 V dc 50/60 Hz E11

200-240 V dc 50/60 Hz E12

208-250 V dc 50/60 Hz E13

220-240 V dc 50/60 Hz E14

220-250 V dc 50/60 Hz E15

360-415 V dc 50/60 Hz E16

265-347 V dc 50/60 Hz E17

380-415 V dc 50/60 Hz E18

380-450 V dc 50/60 Hz E19

400-500 V dc 50/60 Hz E20

430-500 V dc 50/60 Hz E21

440-500 V dc 50/60 Hz E22

440-575 V dc 50/60 Hz E23

575-690 V dc 50/60 Hz E24

12 V dc 50/60 Hz E25

24 V dc 50/60 Hz E26

48 V dc 50/60 Hz E27

60 V dc 50/60 Hz E28

110 V dc 50/60 Hz E29

130 V dc 50/60 Hz E30

220 V dc 50/60 Hz E31

380 V dc 50/60 Hz E32

48 V 50/60 Hz /24Vdc E33

50-127 V 50/60 Hz / 60-180 V dc E34

100-127 V 50/60 Hz / 100-110 V dc E35

100-240 V 50/60 Hz / 100-220 V dc E36

110-130 V 50/60 Hz / 24 V dc E37

130-275 V 50/60 Hz / 180-300 V dc E38

200-240 V 50/60 Hz / 200-220 V dc E39

220-240 V 50/60 Hz / 24 V dc E40

277-380 V 50/60 Hz / 300-510 V dc E41

430-525 V dc 50/60 Hz E42

208-240 V dc 50/60 Hz E43

220-240 V 50/60 Hz / 250 V dc E44

100-110 V 50/60 Hz /110 V dc E45

230 V 50/60 Hz /220 V dc E46

Voltage Codes - Controls

Alternating Current (50/60 Hz) Direct Current Alternating Current / Direct Current

Page 23: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

www.weg.net

Reference Codes - Switchgear 23

Description Code Setting range

RW17-1D3-D004 R01 0.28 - 0.4

RW17-1D3-C063 R02 0.4 - 0.63

RW17-1D3-D008 R03 0.56 - 0.8

RW17-1D3-D012 R04 0.8 - 1.2

RW17-1D3-D018 R05 1.2 - 1.8

RW17-1D3-D028 R06 1.8 - 2.8

RW17-1D3-U004 R07 2.8 - 4

RW17-1D3-D063 R08 4.0 - 6.3

RW17-1D3-U008 R09 5.6 - 8

RW17-1D3-U010 R10 7 - 10

RW17-1D3-D125 R11 8 - 12.5

RW17-1D3-U015 R12 10 - 15

RW17-1D3-U017 R13 11 - 17

RW27-1D3-C063 R21 0.4 - 0.63

RW27-1D3-D008 R22 0.56 - 0.8

RW27-1D3-D012 R23 0.8 - 1.2

RW27-1D3-D018 R24 1.2 - 1.8

RW27-1D3-D028 R25 1.8 - 2.8

RW27-1D3-U004 R26 2.8 - 4

RW27-1D3-D063 R27 4.0 - 6.3

RW27-1D3-U008 R28 5.6 - 8

RW27-1D3-U010 R29 7 - 10

RW27-1D3-D125 R30 8 - 12.5

RW27-1D3-U015 R31 10 - 15

RW27-1D3-U017 R32 11 - 17

RW27-1D3-U023 R33 15 - 23

RW27-1D3-U032 R34 22 - 32

RW67-1D3-U040 R35 25 - 40

RW67-1D3-U050 R37 40 - 57

RW67-2D3-U050 R38 40 - 57

RW67-2D3-U057 R39 50 - 63

RW67-2D3-U063 R40 57 - 70

RW67-2D3-U070 R41 63 - 80

RW67-2D3-U080 R42 63 - 80

RW117-1D3-U097 R44 75 - 97

RW117-1D3-U112 R45 90 - 112

Description Code Setting range

RW17-1D2-D018 RM05 1.2 - 1.8

RW17-1D2-D028 RM06 1.8 - 2.8

RW17-1D2-U004 RM07 2.8 - 4

RW17-1D2-D063 RM08 4 - 6.3

RW27-1D2-D008 RM22 0.56 - 0.8

RW27-1D2-D012 RM23 0.8 - 1.2

RW27-1D2-D018 RM24 1.2 - 1.8

RW27-1D2-D028 RM25 1.8 - 2.8

RW27-1D2-U004 RM26 2.8 - 4

RW27-1D2-D063 RM27 4 - 6.3

RW27-1D2-U008 RM28 5.6 - 8

RW27-1D2-U010 RM29 7 - 10

RW27-1D2-D125 RM30 8 - 12.5

RW27-1D2-U015 RM31 10 - 15

RW27-1D2-U017 RM32 11 - 17

RW27-1D2-U023 RM33 15 - 23

RW27-1D2-U032 RM34 22 - 32

RW67-1D2-U040 RM35 25 - 40

RW67-2D2-U050 RM38 32 - 50

RW67-2D2-U057 RM39 40 - 57

RW67-2D2-U063 RM40 50 - 63

RW67-2D2-U070 RM41 57 - 70

Short Codes for Overload Relays to be Used on Enclosed Direct On Line Starters

Page 24: Reference Codes - WEG ·  2 Reference Codes - Switchgear Power Contactors C W M 1 2 - 1 0 - 3 0 - V 4 0 Model CWMC CWC0 CWCI0 CWCH0 CWM CWB Terminal type Code Screw Blank

WEG Worldwide Operations

WEG Group - Automation Business Unit Jaraguá do Sul - SC - Brazil Phone: +55 47 3276 4000 [email protected] www.weg.net C

od: 5

005

8173

| R

ev: 0

3 | D

ate

(m/y

): 06

/201

5Th

e va

lues

sho

wn

are

sub

ject

to c

hang

e w

ithou

t prio

r no

tice.

For those countries where there is not a WEG own operation, find our local distributor at www.weg.net.

ARGENTINASan Francisco - CordobaPhone: +54 3564 [email protected]

Cordoba - CordobaPhone: +54 351 [email protected]

Buenos AiresPhone: +54 11 [email protected]

AUSTRALIAScoresby - Victoria Phone: +61 3 [email protected]

AUSTRIAMarkt Piesting - Wiener Neustadt-LandPhone: +43 2633 [email protected]

BELGIUMNivelles - BelgiumPhone: +32 67 [email protected]

BRAZILJaraguá do Sul - Santa CatarinaPhone: +55 47 [email protected]

CHILELa Reina - SantiagoPhone: +56 2 [email protected]

CHINANantong - JiangsuPhone: +86 513 [email protected]

Changzhou – Jiangsu Phone: +86 519 [email protected]

COLOMBIASan Cayetano - BogotaPhone: +57 1 [email protected]

ECUADOREl Batan - QuitoPhone: +593 2 [email protected]

FRANCESaint-Quentin-Fallavier - IsèrePhone: +33 4 [email protected]

GERMANYTürnich - Kerpen Phone: +49 2237 [email protected]

Balingen - Baden-WürttembergPhone: +49 7433 [email protected]

Homberg (Efze) - HessePhone: +49 5681 [email protected]

GHANAAccraPhone: +233 30 [email protected]

INDIABangalore - KarnatakaPhone: +91 80 [email protected]

Hosur - Tamil NaduPhone: +91 4344 [email protected]

ITALYCinisello Balsamo - MilanoPhone: +39 2 [email protected]

JAPANYokohama - KanagawaPhone: +81 45 [email protected]

MALAYSIAShah Alam - SelangorPhone: +60 3 [email protected]

MEXICOHuehuetoca - MexicoPhone: +52 55 [email protected]

Tizayuca - HidalgoPhone: +52 77 97963790

NETHERLANDSOldenzaal - OverijsselPhone: +31 541 [email protected]

PERULa Victoria - LimaPhone: +51 1 [email protected]

PORTUGALMaia - PortoPhone: +351 22 [email protected]

RUSSIA and CISSaint PetersburgPhone: +7 812 363 [email protected]

SOUTH AFRICAJohannesburgPhone: +27 11 [email protected]

SPAINCoslada - MadridPhone: +34 91 [email protected]

SINGAPORESingaporePhone: +65 [email protected]

SingaporePhone: +65 [email protected]

SCANDINAVIAMölnlycke - SwedenPhone: +46 31 [email protected]

UKRedditch - WorcestershirePhone: +44 1527 [email protected]

UNITED ARAB EMIRATESJebel Ali - DubaiPhone: +971 4 [email protected]

USADuluth - GeorgiaPhone: +1 678 [email protected]

Minneapolis - MinnesotaPhone: +1 612 3788000

VENEZUELAValencia - CaraboboPhone: +58 241 [email protected]