radiobiological characterization of clinical proton and carbon ...radiobiological characterization...

119
Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels, Belgium John Gueulette Vincent Grégoire Pierre Scalliet

Upload: others

Post on 28-Mar-2021

5 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Radiobiological characterization of

clinical proton and carbon-ion beams :

Université catholique de Louvain, Brussels, Belgium

John Gueulette

Vincent Grégoire

Pierre Scalliet

Page 2: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Improvement of radiotherapy

Page 3: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

There are several

arguments pointing at

the DNA as the main

target of ionising

radiation

What is the biological effect of ionising

radiation?

Immediate death

delayeddeath

Mitotic delay

Page 4: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Ionisations along an electron track (secundary electron after low LET irradiation)

CLUSTER

Page 5: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Sequence of events

• Energy deposits (primary and secondary electrons)

• DNA damage.

• DNA re-arrangement.

• Repair induction (enzyme synthesis).

• Cell cycle arrest.

• Repair vs. apoptosis.

• Cell death

• Tissue failure

Page 6: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,
Page 7: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

DNA is the primary target

Double

strand break

Ionisation and section

of a DNA strand

(single strand break)

Page 8: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Various types of DNA damage

Page 9: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Possible

consequence of

DNA damageapoptosis

ionisation

cell

DNA damage

Repair Misrepair

mutationCell death

Page 10: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Cell death after misrepair

(lethal mutation)

Apoptosis

Page 11: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Base pairs can be

substituted,

or deleted, or added,

all resulting in an alteration

of information.

A gene can be inactivated or

mutated.

A mutation can amplify

or decrease the gene

expression.

Page 12: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

A dose increment kills a fixed proportion of cells

Lo

g S

Dose (Gy)

Exponential survival

curve of prokaryotes and

bacteria

Poisson’s law

S = e-aD

Page 13: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Cell survival curve

survival

dose

Saturated repair

Unsaturated

repair

Survival

curve

Experimentalpoints

Clones can be seen

2 Gy 4 Gy6 Gy

Page 14: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

survival

dose

Survival

without repairsaturation

Page 15: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Initial part of the survival curve

A steep initial part exists on

survival curves, particularely in

resistant cells.

It is interpreted as a sign of

repair induction when and if the

damage concentration is

sufficient to « trigger » repair

enzyme synthesis.

Page 16: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

The linear quadratic model

survival

dose

Survivalcurve

a/b

a component

b component

-logS = ad + bd2

DNA

Double-strand break

Single-strand break

the model of radiation action

Page 17: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Ionisation along a particle track

Low density of

ionisation

High density

of ionisation

ADN

Page 18: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Direct and indirect effects

G Montarou, radiobiology in medicine, 17-12-2013

Page 19: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

ProtonsProtons are sparsely ionising, majority of indirect effects

G Montarou, radiobiology in medicine, 17-12-2013

Page 20: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Carbon ionsCarbon ions are densely ionising, majority of direct effects

G Montarou, radiobiology in medicine, 17-12-2013

Page 21: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,
Page 22: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Scattered

energy deposits,

repair efficient

Dense energy

deposits, repair

inefficient

Page 23: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Induction of

repair

enzymes with

X-rays and

carbon ions,

same

absorbed dose

Page 24: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Track structure

depends on

energy and Z

Page 25: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

“Size » of

radiosensitive

structures

RBE

“waste” of energy

Maximum 50 - 150 keV/mm

Ionization density (LET)

Page 26: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Microdosimetry

Tissue-equivalent proportional counter :

• The sphere is the cathode, in tissue

equivalent material.

• The anode is central.

• The gas filling the sphere is tissue

equivalent (C, N, O, H).

• Its pressure can be adjusted to

simulate small volumes of tissue.

• Irradiation is delivered at extreme low

dose rate.

• Electric charges are collected,

proportional to the individual energy

deposits.

TEPC of Rossi, Columbia University

Page 27: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Lineal energy, y (keV / µ m)

0.01 0.1 1 10 100

5

4

3

2

1

0

Photons

1000

y.d

y

Energy deposition along

the diameter of a sphere of

the same size as the vital

radiosensitive

structures

E

Microdosimetric spectra : a tool for

tracking the RBE variations

Page 28: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,
Page 29: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Energy of the incident particles...

October 2-5, 2003 - Lyon (France)

9th Workshop on heavy Charged Particles in Biology and Medicine 2003 (HCPBM 2003)

General Meeting on the European Network for Light Ion Hadrontherapy (ENLIGHT 2003)

Page 30: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Indentical nominal energy

and identical nuclear reaction ...

October 2-5, 2003 - Lyon (France)

9th Workshop on heavy Charged Particles in Biology and Medicine 2003 (HCPBM 2003)

General Meeting on the European Network for Light Ion Hadrontherapy (ENLIGHT 2003)

Page 31: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Depth ...

Surface7 cm

October 2-5, 2003 - Lyon (France)

9th Workshop on heavy Charged Particles in Biology and Medicine 2003 (HCPBM 2003)

General Meeting on the European Network for Light Ion Hadrontherapy (ENLIGHT 2003)

Page 32: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Summary of pertinent conclusions (1)

Conceptually, RBE is a measure of the biological effectiveness differences related to radiation quality only

RBE is essentially variable and depends on numerous factors related 1) to biology or, 2) to the beam delivery technique

RBE is correlated with ionization density. Roughly speaking, it increases with LET.

Biology : the main sources of RBE variation are : • the biological system (tissue, endpoint, etc.) and • dose, dose rate and fractionation

Beam : the main sources of RBE variation are : • Depth (for heavy ions), • filtration (for fast neutrons), • collimation, etc.

Page 33: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Summary of pertinent conclusions (2)

When determining RBEs, all conditions - but the radiation quality - have to be the same for the intercompared beams

Inherent performance of the beam generators as well as practical reasons (e.g, distance) prevent from adopting ideal experimental procedure

Microdosimetry is a powerful tool for tracking the potential RBE variations

Recourse to indirect method for RBE determination is often required (RBE ratios)

Recourse to fractionated irradiations is most of the time required to determine RBEs for small doses

Page 34: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Bragg peak

Plateau region

Fall-off region

Fragmentationregion

PROTONS

HEAVY IONS

Depth in tissue

Rela

tive d

ose

Page 35: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Most events are in the 1

keV/mm range, with a

significant component

around 10

End of Bragg peak

Most events are in the

range 10-30 keV/mm

range, with a significant

component around 100.

Plateau (entry beam)

Proton beam (Nice)

Spectrum : sum of individual energy deposits

Page 36: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Proton beam (Nice)

Let increases

as the beam

progresses

in depth

(SOBP)

Page 37: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Density of energy deposits in

the Bragg peak of carbon ions

Page 38: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Linear energy transfer (LET)

• LET is the physical

quantity of ionisation

density; its unit is the

keV/mm.

• The higher the LET, the

broader the DNA

damage and, hence, the

larger the biological

effect

dose

survival High LET

Low LET

Page 39: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

RBE ?

The relative biological

effectiveness is a ratio of

dose:

DlowLET/DhighLET

for any given level of effect

survival High LET

Low LET

Dlow Dhigh

S

Page 40: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

0

1

10

100

1000

0 5 10 15 20

Nu

mb

er o

f r

egen

era

ted

cryp

ts

Dose / Gy

Neutrons [p(45)+Be] (Seattle)

Cobalt-60 gamma-rays

R

B

E

All the irradiations

performed under the

same conditions, e.g. :

Animals from the same population

Same day (and moment in the day)

Randomized (dose / radiation quality)

Acute dose rate

Irradiation in a single fraction

Same experimenters

Reliable dosimetry

Etc.

RBE accounts for the biological effectiveness difference

related only to the radiation quality difference

Page 41: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Different radiation quality have

different RBE’s

& X-rays

Page 42: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Oxygen effect

Page 43: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

4MeV d-Be

OER = 3.0OER = 1.7

Reduced effect of oxygen

Page 44: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

As LET increases OER decreases

Page 45: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Healthy tissues

Tumor

Reduction of radiosensitivity differences :

Potential therapeutic advantage

when the tumor is radioresistant

in comparison with healthy tissues

Potential therapeutic benefit due to the reduction

of an unfavourable differential effect

Dose (gamma) Dose (neutrons)

Surv

ivin

g F

ractions (

%)

Surv

ivin

g F

ractions (

%)

Radioresistant

or hypoxic

tumour

Page 46: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Healthy tissues

Tumor

Reduction of radiosensitivity differences :

contra-indication

when the healthy tissues are radioresistant

In comparison with the tumor

Contra-indication due to the reduction of

a favorable differentiel effect

Surv

ivin

g F

ractions (

%)

Surv

ivin

g F

ractions (

%)

Dose (gamma) Dose (neutrons)

Page 47: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Buid-up of radiobiological

experience and disclosure

of potential benefits

Safe and optimum

clinical application

Transfer of radiobiological /

clinical information and

coherency of treatments

« Pretherapeutic »

experiments

Radiobiological

Calibration /

Intercomparison

« Preclinical »

experiments

Hadron RBE is

different than that

of photons

RBE varies with

« radiation quality »

All the beams are

different

Page 48: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Protons

Heavy ions

Neutrons

Summary of in vivo data on jejunal crypt cells

Page 49: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

RBE variations related

to biological system

RBE variation related

to radiation quality

(energy)

Rationale for clinical

application of high-LET

radiations

Emergence

of problems

related to :

Transferring clinical and radiobiological information

Pooling clinical data

Optimizing clinical applications

Comparing with conventional radiations

Page 50: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Differential

Effect(neutrons, ions)

NO

differential

effect

(protons)

Page 51: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Potential advantage of protons

is essentially ballistic

Proton RBEs are too small to result

in a workable differential effect

Proton RBEs are big in comparison

with dose accuracy requirements ...

and raise essentially

Bio-dosimetry questions

Page 52: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Gamma Equivalent Dose =

physical dose x RBE

Uncertainties in RBE values lead to

equal uncertainties in the derived

Gamma Equivalent Doses

The dose accuracy required in

radiotherapy is 3.5 %

Page 53: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Substantial spread between cell lines and

conflicting conclusions about :

In vitro systems

(Proton RBE = 0.94 - 1.63)

• RBE value in reference conditions (energy, depth)

• possible RBE increase with depth

• possible RBE increase with SF (or fractionation)

Page 54: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Possible causes of the spread of the data :

In vitro systems

(Proton RBE = 0.94 - 1.63)

• Dosimetry ?

• Underlying theory (model to fit the data)

• Randomization ?

• Platting efficiency ?

Uncertainties above 20 %

Page 55: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Limited amount of data. Present-day questions are :

In vivo systemsProton RBE 1.08 - 1.17

• RBE increase with fractionation ?

• RBE difference for early and late tissue tolerance ?

• RBE increase with depth ?

Page 56: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Which system to use for

calibrating

intercomparing

clinical proton beams ?

Page 57: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Systems and endpoints which

result in widely different values for

the RBE of neutron relative to X-

rays ...

n g1

EBR =

2

Neutronscompared

with gamma

... give similar values for the

RBE differences between two

closely related neutron energies

1n2 n

EBR =

1.1

Neutrons compared

with neutrons

1 gn

3

n n12

1.1

Page 58: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Consequently, the choice

of a biological system for

intercomparisons should be governed

largely by its

• portability,

• repeatability

• and convenience.J. Hall, 1979

Page 59: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Intestinal crypts

regeneration in mice

In - vivo system, based on

Cell lethality

Page 60: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,
Page 61: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

84 hTested beam

Clinical dose rate

Position dependingon the type of beam

Reference beam

Cobalt-60 or 7 MV

1 Gy / min

Depth of the peak

dose

Single fraction

Irradiation to the

whole body

Page 62: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Protons

Neutrons

Reproducibility...

Page 63: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Radiobiological

characterization

(protons)

Page 64: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Influence of depth

Page 65: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,
Page 66: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

< 5 %

Page 67: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

PSI

Spot scanning

RBE =

1.11 1.16 1.21

~ 4 %

Page 68: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Dose / Gy

Num

ber

of re

genera

ted c

rypts

per

circum

fere

nce

RBE difference of 7 %

End SOBP

Middle

SOBP

0 1 2 3 4 5 6 7

SOBP (cm)

7 %

Page 69: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

1 fract. 10 fract.3 fract.

RBE = 1.14

± 07

RBE = 1.15

± 0.6

Num

ber

of

regenera

ted c

rypts

per

cir

cum

fere

nce

RBE = 1.15

± 0.5

RBE (end) / RBE (middle) ~ 1.08

i = 4 h

Intestine (10 fractions)

Page 70: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Selective thoracic irradiation in mice

Irradiation in 10 fractions (i = 12 h)

(middle vs end of the SOBP)

< 6 %

Page 71: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

RB

E r

ela

tive t

o p

hoto

ns

RBE increases

suddenly

by 6 - 10° %

from the middle

to the end of the

SOBP

Page 72: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

200 MeV

protons

More precise irradiation is possible

1.5 cm

Page 73: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,
Page 74: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

iThemba LABS (2006)

200 MeV protons, 7-cm SOBP

0,1

1

10

100

1000

8 10 12 14 16 18

End

SOBP

Middle

SOBP

Dose / Gy

Nu

mb

er

of re

ge

ne

rate

d c

ryp

ts

pe

r cir

cu

mfe

rence

RBE (end)

RBE (middle)= 1.10

7 cm

3 mm

Page 75: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

As an increase in RBE is

observed at the end of the SOBP

in all biological systems, it is

advisable to allow for it.

TPS should include biological

weighting functions

Page 76: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Influence of

fractionation

(or dose)

Page 77: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Crypt regeneration in mice

Bloomington, IN (USA) Midwest Proton Radiation-therapy Institute, Friday, July 9, 2004

Page 78: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Protons

Cobalt

Bloomington, IN (USA) Midwest Proton Radiation-therapy Institute, Friday, July 9, 2004

Page 79: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Bloomington, IN (USA) Midwest Proton Radiation-therapy Institute, Friday, July 9, 2004

Page 80: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,
Page 81: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

1 fract. 10 fract.3 fract.

RBE = 1.14

± 07

RBE = 1.15

± 0.6

Nu

mbe

r of

rege

ne

rate

d c

rypts

per

cir

cum

fere

nce

RBE = 1.15

± 0.5

Irradiation at the middle of a 7 cm SOBP

in the 200-MeV proton beam produced at the

National Accelerator Centre (NAC) of Faure (South Africa).

i = 4 h

Page 82: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Late tolerance

(Survival after selective irradiation

of the thorax in mice)

Page 83: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

8 months 9 months

6 months 7 months

Page 84: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

RBE = 1.14

± 07

Lung (10 fractions) Intestine (10 fractions)

For both systems (10 fraction irradiations)

RBE at the end of the SOBP ~ 6 % greater that at the middle

Page 85: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Proton RBE (at the middle of the

SOBP) does not vary with dose

(or fractionation) for in vivo systems

A generic RBE value of 1.10 at the

middle of the SOBP (i.e. point of dose

specification) seems to be appropriate

Page 86: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Proton RBE In-vitro, as a function of

dose, for all “clinical” energies

All in vivo

Late

reactions

Acute

reactions

All in vitro

V79 lines

non V79

lines

Proton RBE In-vivo, as a function of

dose, for all “clinical” energies

1.10

1.10

1.10

1.19

1.24

1.12

From Paganetti et al. (2002)

Page 87: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

HEAVY IONS

Page 88: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

He

C

PMegavoltage

X rays

Neutrons

Page 89: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Salivary gland tumour treated with fast neutrons

Study results (± 1985)

17% ± 11 vs. 67% ± 14 25% ± 14 vs. 62% ± 14

Page 90: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Randomized clinical trial of photons vs mixed

beam neutrons plus photons for prostate Ca

RTOG 77-04

Laramore et al, 1993.

Prostate carcinomas are slow

growing and hence should be well

suited for neutron therapy. The

neutrons are usually used for the

small “boost” volume in order to

minimize late normal tissue

damage.

Page 91: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Laramore, 1993

Page 92: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Nature April, 2014

Page 93: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Which RBE to apply ?

Late tolerance of healthy surrounding tissues

Dose per fraction of 2 Gy photon equivalent

Not a single value

• due to the diversity of the clinical situations

• due to variation of RBE with depth/dose

Page 94: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Density of energy deposits in

the Bragg peak of carbon ions

Page 95: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

From Peter Peschke, Heidelberg

Page 96: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,
Page 97: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,
Page 98: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Depth in water / mm

RB

E

1,0

1,2

1,4

1,6

1,8

2,0

2,2

0 50 100 150 200

HIMAC (Japan) : Carbon-12

(290 MeV/uma)

6-cm SOBP

EBR = 1.3

EBR = 1.6

EBR = 1.7

EBR = 1.9

Page 99: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

1

3

2

0

50 100 150

Depth / mm

Ab

sorb

ed

do

se /

Gy

1

3

2

Isoe

ffective

do

se / G

y

0 200

x1.6

: 1.3

:1.6 :1.7 :1.9

Biologically

effective dose

Physical

dose

Depth in water / mm

Ab

so

rbe

d d

os

e /

Gy

Compensate the RBE

increase by

decreasing the

physical dose

by factors

corresponding to the

(local) RBE

Method used in static beam delivery

systems (Chiba, Japan)

Effe

ctiv

e d

ose/ G

y

Page 100: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

1

3

2

0

50 100 150

Depth / mm

1

3

2

0 200

Carbon dose x RBE

Iso

effe

ctiv

e d

ose/ G

y

Ab

so

rbe

d d

os

e /

Gy

Depth in water / mm

x1.6x1.7

x1.9

x1.3

Photon

equivalent

biologically

effective dose

A given dose of carbon is biologically

equivalent to the same dose of

gamma multiplied by the carbon RBE

Physical d

ose

Ab

sorb

ed

do

se /

Gy

Iso-doses (in Gy) in a given

tissue do no longer

correspond to

iso-biologically effective

doses !!!

Page 101: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

1

3

2

0

50 100 150

Depth in water / mm

No

rma

lize

d a

bs

orb

ed

do

se

1

3

2

No

rma

lize

d is

oe

ffec

tive

do

se

0 200

CARBON ION BEAM

290 MeV / amu

X 2.7

X 3.4

X 3.0

X 2.1

Page 102: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

LEM“Local effect Model” (Scholz et Kraft, 1994)

Derivation of parametres determining the biological

response to a Carbon ion exposure from the

response parameters to a photon irradiation

Page 103: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

The biological effect in a cell nucleus sub-volume is exclusively determined by theenergy deposit in this sub-volume

The biological effect is independent from theradiation quality of the beam

A local dose deposit with Carbon ionsproduces the same biological effect than thesame dose deposit with photons

Therefore, the different biological effects ofCarbon ion and photons result fromdifferences in spatial dose deposition

Assumptions

Consequences

Page 104: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Local Effect Model (LEM)(Scholz and Kraft)

Dose-effect relationship for photons (low LET)

Probability of a letal event

Physical data on track structures

Determination of local dose deposits

Experimental measurement of cell nucleus size

Determination of radiosensitive area size

Parameters exclusively determined on the basis of :

(nucleus diameter)

Page 105: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Advantages :

• Uncertainties on RBE calculation algorithm (LEM, other…)

• Lack of transparency and total confidence in

calculation model

• Impossibility (for the physician nor for the physicist)

to judge directly the appropriateness of treatments plans.

Dose distributions have to be re-calculated with the model.

Inconvenients

• Conformational possibilities

• Possibility to treat sub-volumes

• Possibility of dose « modulation » within each volume of interest

• all RBE variation taken into account

Page 106: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

RBE

NIRS neutrons

80 keV/mm

8 mm apart from

the distal edge

Page 107: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

RBE

NIRS neutrons

Neutron clinical

RBE = 3

Carbon clinical RBE at the

center of the SOBP = 2.38

Page 108: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Scanner magnets

Raster scan system at GSI, Germany

from : D. Schulz-Ertner, O. Jäkel, W. Schlegel

Page 109: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

i.e. a system where :

“several thousands of narrow ion pencil beams

with individual lateral positions, ion energies

and particle fluences are combined to form an

intensity-modulated field of high granularity”

(M. Krämer, 2001)

Consideration of RBE variations is only

possible in an integrated calulation code

allowing iterative interaction between both

physical and biological input parameters

Page 110: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,
Page 111: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Integrated algorithm allowing for the iterative

interaction between physical (e.g. energy/LET) and

biological parameters (e.g. intrinsic radiosensitivity,

oxygenation, dose rates, micro-fractionation, etc.

An RBE weighting factor should be applied at each point

of the irradiated volume, taking RBE variation with energy,

dose, biological system, etc, into account

Particules of variable energy are also delivered at variable dose rates or in multi - micro

fractions.

Page 112: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Over dosage

M oving target

Under dosage

M oving target

The “Inter–play” effect (Protons, PSI)

Number of regenerated

crypts per circumference

Sta

ndard

devia

tion

Dose heterogeneity

~ 15% / mm

U

T

U

T

T

T

Rel

ativ

e d

ose

y - axis y - axis

x -

axis

a b

a

b

a

b

diffusion

PBS

Page 113: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Pitfalls...

Page 114: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,
Page 115: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,
Page 116: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,
Page 117: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

~ 1 % of the surface

Page 118: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

~ 1 % of the surface

Page 119: Radiobiological characterization of clinical proton and carbon ...Radiobiological characterization of clinical proton and carbon-ion beams : Université catholique de Louvain, Brussels,

Finally, which recommendation for irradiation

schedule?

Short hypofractionated schedules

• Less tumour repopulation.

• More damage to quiescent cells.

• More microvascular damage.

• Differential release of cytokines and special

immunologic effects?

• Too much assumptions in radiobiological

models??