product manual - long span iii panel - wall covering

23
Product Manual - Long Span III Panel - Wall Covering EA37/AB, Outside Closure Installation at Eave RA01/AB, Panel Closure Detail at Rake WC05/AB, Fastener Layout WC06/AB, Wall Panel Endlap WC08/AB, Pre-Drilling for Fastener Locations WC20/AB, Typical Corner Detail at Panels WC21/AB, Corner Flashing Detail (Outside) WC21B/AB, Corner Flashing Detail (Outside) at Open Wall Transition WC26/AB, Corner Flashing Detail (Inside) WC26B/AB, Corner Flashing Detail (Inside) At Open Wall Transition WC40/AB, Partially Open Wall Base Trim at Girt With Flush Panel WC41/AB, Partially Open Wall Base Trim at Girt, Panel Extends 1 1/2" WC61/AB, Basic Parts and Pieces WC64/AB, Wall Panel Installation WC75/AB, Panel Backlapping WC80/AB, Transverse Expansion Joint Detail at Sidewall WWC20/AB, Typical Corner Detail at Panels WWC21/AB, Corner Flashing Detail (Outside) WWC21B/AB, Corner Flashing Detail (Outside) at Open Wall WWC26B/AB, Corner Flashing Detail (Inside) At Open Wall Ti WWC40/AB, Partially Open Wall Base Trim at Girt With Flush Panel WWC41/AB, Partially Open Wall Base Trim at Girt, Panel Ex 2/17/2021

Upload: others

Post on 17-Feb-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

Product Manual - Long Span III Panel - Wall Covering

EA37/AB, Outside Closure Installation at EaveRA01/AB, Panel Closure Detail at RakeWC05/AB, Fastener LayoutWC06/AB, Wall Panel EndlapWC08/AB, Pre-Drilling for Fastener LocationsWC20/AB, Typical Corner Detail at PanelsWC21/AB, Corner Flashing Detail (Outside)WC21B/AB, Corner Flashing Detail (Outside) at Open Wall TransitionWC26/AB, Corner Flashing Detail (Inside)WC26B/AB, Corner Flashing Detail (Inside) At Open Wall TransitionWC40/AB, Partially Open Wall Base Trim at Girt With Flush PanelWC41/AB, Partially Open Wall Base Trim at Girt, Panel Extends 1 1/2"WC61/AB, Basic Parts and PiecesWC64/AB, Wall Panel InstallationWC75/AB, Panel BacklappingWC80/AB, Transverse Expansion Joint Detail at SidewallWWC20/AB, Typical Corner Detail at PanelsWWC21/AB, Corner Flashing Detail (Outside)WWC21B/AB, Corner Flashing Detail (Outside) at Open WallWWC26B/AB, Corner Flashing Detail (Inside) At Open Wall TiWWC40/AB, Partially Open Wall Base Trim at Girt With Flush PanelWWC41/AB, Partially Open Wall Base Trim at Girt, Panel Ex

2/17/2021

RODUCT ANUALLONG SPAN III WALL PANEL

P M

Revised 04.01.2018

Outside Closure Installation at Eave

Long Span III Wall

EA37/AB

To Section Index

Download the DWG file by clicking here.

RODUCT ANUALLONG SPAN III WALL PANEL

P M

Revised 8/31/2018

Fastener Layout

Long Span III Wall

WC05/AB

To Section Index

Download the DWG file by clicking here.

RODUCT ANUALLONG SPAN III WALL PANEL

P M

Revised 8/31/2018

Wall Panel Endlap

Architectural III, Architectural "V" Rib or Long Span III Walls

WC06/AB

To Section Index

Download the DWG file by clicking here.

RODUCT ANUALLONG SPAN III WALL PANEL

P M

Issued 9/28/2016

Pre-Drilling for Fastener Locations

Long Span III Wall

WC08/AB

To Section Index

Download the DWG file by clicking here.

RODUCT ANUALLONG SPAN III WALL PANEL

P M

Revised: 11-15-2019 (MR2019.12)

Typical Corner Detail at Panels

Long Span III Wall

WC20/AB

To Section Index

Download the DWG file by clicking here.

DO NOT USE AN AEROSOL TYPE PAINT FOR TOUCH UP.

4. USE TOUCH UP PAINT WITH AN ARTIST TYPE BRUSH.

FASTENERS.

3. PANEL SIDELAPS STITCHED 2'-0" ON CENTER WITH #14 WALL

2. PANELS MUST BE INSTALLED SQUARE WITH BUILDING FRAME.

MAINTAIN 3'-0" COVERAGE PER PANEL.

1. CROWD OR STRETCH PANELS SLIGHTLY AS NECESSARY TO

GENERAL NOTES:

OF PANELS AT SCREW LOCATIONS.FAILURE TO MAINTAIN VERTICAL GIRT FLANGES WILL CAUSE DIMPLING

5. GIRTS ARE TO BE BLOCKED TO MAINTAIN VERTICAL GIRT FLANGES.

6. USE #12X2 FASTENER(S) w/ 6" INSULATION

(GIRTS TOED UP SHOWN, TOED DOWN SIMILAR)

RODUCT ANUALLONG SPAN III WALL PANEL

P M

Revised 8/31/2018

Corner Flashing Detail (Outside)

Long Span III Wall

WC21/AB

To Section Index

Download the DWG file by clicking here.

RODUCT ANUALLONG SPAN III WALL PANEL

P M

Revised 8/31/2018

Corner Flashing Detail (Outside) at Open Wall Transition

Long Span III Wall

WC21B/AB

To Section Index

Download the DWG file by clicking here.

RODUCT ANUALLONG SPAN III WALL PANEL

P M

Revised 8/31/2018

Corner Flashing Detail (Inside)

Long Span III Wall

WC26/AB

To Section Index

Download the DWG file by clicking here.

RODUCT ANUALLONG SPAN III WALL PANEL

P M

Revised 8/31/2018

Corner Flashing Detail (Inside) At Open Wall Transition

Long Span III Wall

WC26B/AB

To Section Index

Download the DWG file by clicking here.

RODUCT ANUALLONG SPAN III WALL PANEL

P M

Revised: 11-15-2019 (MR2019.12)

Partially Open Wall Base Trim at Girt With Flush Panel

Architectural III, Architectural "V" Rib or Long Span III Walls

WC40/AB

To Section Index

Download the DWG file by clicking here.

PARTIALLY OPEN WALL BASE TRIM AT GIRT WITH FLUSH PANEL ARCHITECTURAL III, ARCHITECTURAL "V" RIB OR LONG SPAN III WALLS

WC40

AB

VFF7

FPEC1-10.2

BLIND RIVET

WALL PANEL

WALL MAIN FASTENER(S)#12X1 1/4 (SEE NOTE)1'-0" O.C.

1/8" RIVET

1'-0" O.C.

NOTE: #12X2 FASTENERS w/ 6" INSULATION.

GIRT (TOED UP SHOWN/

TOED DOWN SIMILAR)

RODUCT ANUALLONG SPAN III WALL PANEL

P M

Revised: 11-15-2019 (MR2019.12)

Partially Open Wall Base Trim at Girt, Panel Extends 1 1/2"

Architectural III, Architectural "V" Rib or Long Span III Walls

WC41/AB

To Section Index

Download the DWG file by clicking here.

PARTIALLY OPEN WALL BASE TRIM AT GIRT, PANEL EXTENDS 1 1/2" ARCHITECTURAL III, ARCHITECTURAL "V" RIB OR LONG SPAN III WALLS

WC41

AB

VFF7

FPEC1-10.2

BLIND RIVET

WALL PANEL

1 1/2"

WALL MAIN FASTENER(S)

1'-0" O.C.

1/8 RIVET

1'-0" O.C.

#12X1 1/4 (SEE NOTE)

NOTE: #12X2 FASTENERS w/ 6" INSULATION.

GIRT (TOED UP SHOWN/

TOED DOWN SIMILAR)

RODUCT ANUALLONG SPAN III WALL PANEL

P M

Revised 8/31/2018

Wall Panel Installation

Architectural III, Architectural "V" Rib or Long Span III Walls

WC64/AB

To Section Index

Download the DWG file by clicking here.

RODUCT ANUALLONG SPAN III WALL PANEL

P M

Issued 9/28/2016

Panel Backlapping

Architectural III, Architectural "V" Rib or Long Span III Walls

WC75/AB

To Section Index

Download the DWG file by clicking here.

RODUCT ANUALLONG SPAN III WALL PANEL

P M

Issued 9/28/2016

Transverse Expansion Joint Detail at Sidewall

Long Span III Wall

WC80/AB

To Section Index

Download the DWG file by clicking here.

RODUCT ANUALLONG SPAN III WALL PANEL

P M

Revised 11/15/2019 (MR2019.12)

Typical Corner Detail at Panels

Long Span III Wall

WWC20/AB

To Section Index

Download the DWG file by clicking here.

FBC-1BASE ANGLE CORNER

REQUIRED IF ORDERED

OUTSIDE CLOSURE

GABLE MEMBER

CORNER FLASHING

LONG SPAN III WALL PANELS

TYPICAL CORNER DETAIL AT PANELS

GENERAL NOTES:

BASE ANGLE

AB

WWC20

1'-0 O.C.

1'-0" O.C. AT PANEL RIBS

GIRT

RAKE FLASHING

LONG SPAN III PANELS

WOOD BLOCKING(BY OTHERS)

(SEE NOTE 5)

BA-20

WALL MAIN FASTENER(S)

WALL TRIM FASTENER(S)#14X3/4

#14 X 3/4 WALL TRIM FASTENER(S)

2'-0" O.C. AT PANEL SIDELAPS

EAVE STRUT

#14X3/4 1'-0" O.C. AT PANEL RIBS

WALL TRIM FASTENER(S)

EAVE SUPPORTFLASHING

EAVE CLOSURE FLASHING

RA01

AB

OCA01

DO NOT STEP, SIT OR CLIMB ON WALL

GIRTS OR EAVE STRUTS. FAILURE TO ADHERE

SAFETY PRECAUTION:

TO THIS PRECAUTION MAY RESULT IN ASERIOUS INJURY.

DO NOT USE AN AEROSOL TYPE PAINT FOR TOUCH UP.

4. USE TOUCH UP PAINT WITH AN ARTIST TYPE BRUSH.

FASTENERS.

3. PANEL SIDELAPS STITCHED 2'-0" ON CENTER WITH #14 WALL

2. PANELS MUST BE INSTALLED SQUARE WITH BUILDING FRAME.

MAINTAIN 3'-0" COVERAGE PER PANEL.

1. CROWD OR STRETCH PANELS SLIGHTLY AS NECESSARY TO

OF PANELS AT SCREW LOCATIONS.FAILURE TO MAINTAIN VERTICAL GIRT FLANGES WILL CAUSE DIMPLING

5. GIRTS ARE TO BE BLOCKED TO MAINTAIN VERTICAL GIRT FLANGES.

#12X1 1/4 (SEE NOTE 6)

6. USE #12X2 FASTENER(S) w/ 6" INSULATION

(GIRTS SHOWN TOED UP, TOED DOWN SIMILAR)

RODUCT ANUALLONG SPAN III WALL PANEL

P M

Issued 12/14/2018

Corner Flashing Detail (Outside)

Long Span III Wall

WWC21/AB

To Section Index

Download the DWG file by clicking here.

CORNER FLASHING DETAIL (OUTSIDE)

LONG SPAN III WALLS

WWC21AB

STRUCTURAL LINEGIRT LINE OR

(6) PER FLASHING LAP

BLIND RIVET TYPICAL1/8 RIVET

LONG SPAN III PANEL

CORNER FLASHINGOCA01

1'-0" O.C.

#14X3/4 2'-0" O.C.

WALL TRIM FASTENER(S)

NOTES:

1. FIELD TRIM PANELS AS REQUIRED AT CORNERS.

WALL MAIN FASTENER(S)

#12X1 1/4 (SEE NOTE 2)

2. USE #12X2 FASTENER(S) w/ 6" INSULATION

RODUCT ANUALLONG SPAN III WALL PANEL

P M

Revised 11-15-2019 (MR2019.12)

Partially Open Wall Base Trim at Girt With Flush Panel

Architectural III, Architectural "V" Rib or Long Span III Walls

WWC40/AB

To Section Index

Download the DWG file by clicking here.

PARTIALLY OPEN WALL BASE TRIM AT GIRT WITH FLUSH PANEL ARCHITECTURAL III, ARCHITECTURAL "V" RIB OR LONG SPAN III WALLS

WWC40

AB

FPEC1-10.2

BLIIND RIVET

WALL PANEL

1'-0" O.C.

1/8" RIVET

1'-0" O.C.

DRIP FLASHING

BSD02

WALL MAIN FASTENER(S)

#12X1 1/4 (SEE NOTE)

NOTE:

USE #12X2 FASTENER(S) w/ 6" INSULATION

GIRT (TOED UP SHOWN/

TOED DOWN SIMILAR)

RODUCT ANUALLONG SPAN III WALL PANEL

P M

Revised 11-15-2019 (MR2019.12)

Partially Open Wall Base Trim at Girt, Panel Extends 1 1/2"

Architectural III, Architectural "V" Rib or Long Span III Walls

WWC41/AB

To Section Index

Download the DWG file by clicking here.

PARTIALLY OPEN WALL BASE TRIM AT GIRT, PANEL EXTENDS 1 1/2" ARCHITECTURAL III, ARCHITECTURAL "V" RIB OR LONG SPAN III WALLS

WWC41

AB

FPEC1-10.2

BLIIND RIVET

WALL PANEL

1 1/2"

1'-0" O.C.

1/8 RIVET

1'-0" O.C.

BSD02DRIP FLASHING

WALL MAIN FASTENER(S)

#12X1 1/4 (SEE NOTE)

NOTE:

USE #12X2 FASTENER(S) w/ 6" INSULATION

GIRT (TOED UP SHOWN/

TOED DOWN SIMILAR)