euroclad vieo vertical wall covering system over timber facing

12
Ply/Timber/OSB facing by others in accordance with relevent standards. 454mm Nominal 27 Nominal Standard offer is 454mm profile. Also available on request in other widths from 225mm to 517mm. ISSUE DATE: Sep 2014 SCALE: NTS TITLE: Vieo Vertical Wall Covering (On Ply or OSB) DWG NO: V10_VWC_TD_System (To be read in conjunction with Vieo system specification documents) Euro Clad Ltd, Wentloog Corporate Park, Wentloog Road, Cardiff CF3 2ER Tel: (+44) 029 20 790722, Fax: (+44) 029 20 793149 Website: www.vieoroof.com This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property. Drawn by: MP Checked by: PCl

Upload: euroclad-ltd

Post on 23-Jul-2016

222 views

Category:

Documents


1 download

DESCRIPTION

Euroclad vieo vertical wall covering system over timber facing

TRANSCRIPT

Page 1: Euroclad Vieo vertical wall covering system over timber facing

Ply/Timber/OSB facing by others in accordance with

relevent standards.

454mm Nominal

27

Nominal

Standard offer is 454mm profile.

Also available on request in other widths from 225mm to 517mm.

ISSUE DATE: Sep 2014

SCALE: NTS

TITLE: Vieo Vertical Wall Covering (On Ply or OSB)

DWG NO: V10_VWC_TD_System

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: MP Checked by: PCl

Page 2: Euroclad Vieo vertical wall covering system over timber facing

Elite Breather

Membrane

COLOUR SIDE

Elite Breather

Membrane

Vieo_25_454 Profile

Vieo Sliding Clip

Ply/Timber/OSB facing

by Others in accordance with

relevent standards.

CLIP TYPICAL CENTRES:

DETERMINED BY PROJECT WIND SUCTION LOADS AS FOLLOWS:

1260mm for loads up to 1.5kN/M²

660mm for loads 1.5 to 2.0kN/M²

300mm for loads 2 to 4kN/M²

Where substrate is Min 18mm ply or Min 15mm OSB 3

* STAGE 1 SEAM: REDUCED LOAD CAPACITY FOR ALUMINIUM

*REFER TO TECHNICAL

TYPICAL ARRANGEMENT: 1260mm IN CENTRAL AREAS,

REDUCE CLIP CENTRES AT CORNERS AND IN HIGH LOAD AREAS.

CHECK SYSTEM CAPACITY AGAINST PROJECT LOADS AND ADJUST

IF NECESSARY

Vieo Sheet Seaming Sequence

"Stage 1 Seam"

"Stage 2 Seam" (Aluminium Material Only)

ISSUE DATE: Sep 2014

SCALE: NTS

TITLE: Vieo Vertical Wall Covering (On Ply or OSB)

DWG NO: V10_VWC_TD_System

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: MP Checked by: PCl

Page 3: Euroclad Vieo vertical wall covering system over timber facing

Drip Angle flashing

Appropriate where expansion

allowance of Max 10mm required.

Fixed Point

ISSUE DATE: Sep 2014

SCALE: NTS

TITLE: Vieo Vertical Wall Covering (On Ply or OSB)

DWG NO: V10_VWC_TD_System

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: MP Checked by: PCl

Page 4: Euroclad Vieo vertical wall covering system over timber facing

POSITIONS

Fixed Point Expansion allowance under flashing

ISSUE DATE: Sep 2014

SCALE: NTS

TITLE: Vieo Vertical Wall Covering (On Ply or OSB)

DWG NO: V10_VWC_TD_System

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: MP Checked by: PCl

Page 5: Euroclad Vieo vertical wall covering system over timber facing

Assembled Front View

Create Fixed Point Using Clip with Additional Fixing,

Typically positioned over drip angle at sheet base.

Drip Angle flashing

Drip Angle flashing

Appropriate where expansion

allowance of Max 10mm required.

Fixed Point

ISSUE DATE: Sep 2014

SCALE: NTS

TITLE: Vieo Vertical Wall Covering (On Ply or OSB)

DWG NO: V10_VWC_TD_System

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: MP Checked by: PCl

Page 6: Euroclad Vieo vertical wall covering system over timber facing

Movement typically allowed

at top of sheet.

Closure with flashing fixed to

decking and not through sheet.

Maxim

um

75m

m

* Allow clearance for anticipated

movement between support Closure, end

of Vieo sheet & Ridge Closure

*

Flashing fixed to inverted Ridge Closure

(Appropriate where expansion allowance

up to 30mm is required)

Maximum allowable to

next Vieo clip 300mm

#

# end of Vieo sheet must fall under

downslope edge of inverted Closure

Maximum allowable distance

to next Vieo clip 300mm from

closure fixing

Cover flashings fixed

to structure and Vieo

Closure

Appropriate where expansion

allowance of Max 10mm required

ISSUE DATE: Sep 2014

SCALE: NTS

TITLE: Vieo Vertical Wall Covering (On Ply or OSB)

DWG NO: V10_VWC_TD_System

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: MP Checked by: PCl

Page 7: Euroclad Vieo vertical wall covering system over timber facing

Drip Angle flashing

Appropriate where expansion

allowance of Max 10mm required.

ISSUE DATE: Sep 2014

SCALE: NTS

TITLE: Vieo Vertical Wall Covering (On Ply or OSB)

DWG NO: V10_VWC_TD_System

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: MP Checked by: PCl

Page 8: Euroclad Vieo vertical wall covering system over timber facing

Create Fixed Point Using

Clip with Additional Fixing,

Typically positioned over

drip angle at sheet base.

Drip Angle flashing

Verge Closure

Sheet seamed

to clip

Verge ClosureSheet seamed

to clip

Cill flashing (with optional fall).

Edge cut on site and turned up

behind Jamb flashing.

Site folded stopend also formed

by cut and fold back.

Use appropriate head detail

for required expansion.

Head Detail Cill Detail

Jamb Details

ISSUE DATE: Sep 2014

SCALE: NTS

TITLE: Vieo Vertical Wall Covering (On Ply or OSB)

DWG NO: V10_VWC_TD_System

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: MP Checked by: PCl

Page 9: Euroclad Vieo vertical wall covering system over timber facing

Small notch into Vieo sheet

to receive drip. Sealed with

mastic.

Design Window Module & Vieo sheet

to be in line. Either by using multiples

of 454mm or adjustment of Vieo sheet

coverwidth.

Site Folded stopend on drip

ISSUE DATE: Sep 2014

SCALE: NTS

TITLE: Vieo Vertical Wall Covering (On Ply or OSB)

DWG NO: V10_VWC_TD_System

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: MP Checked by: PCl

Page 10: Euroclad Vieo vertical wall covering system over timber facing

Create Fixed Point Using Clip with

Additional Fixing,

Typically positioned over drip angle at

sheet base.

Drip Angle flashing

Angle flashing should not be fixed

to jamb flashing or structure

Angle rivetted and sealed to cut sheet

edge prior to offering to structure

Colour side

Cill flashing.

Edge cut on site and turned up

behind Jamb flashing.

Site folded stopend also formed

by cut and fold back.

Optional closure flashing dependent

on visibility, exposure to elements,

insects etc.

Head Detail Cill Detail

Jamb Details

ISSUE DATE: Sep 2014

SCALE: NTS

TITLE: Vieo Vertical Wall Covering (On Ply or OSB)

DWG NO: V10_VWC_TD_System

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: MP Checked by: PCl

Page 11: Euroclad Vieo vertical wall covering system over timber facing

Vieo Sheet

Breather Membrane

Flashing rivetted to closure

@ 600mm centres

Vieo Closure

ISSUE DATE: Sep 2014

SCALE: NTS

TITLE: Vieo Vertical Wall Covering (On Ply or OSB)

DWG NO: V10_VWC_TD_System

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: MP Checked by: PCl

Page 12: Euroclad Vieo vertical wall covering system over timber facing

50m

m Joggle (Form

ed O

nsite)

9x2 Mastic sealant

to pan & upstands of

underlap

Vieo Standard Sheet

Vieo Lapping Sheet

3 Rivets in each pan

Create fixed points at clips immediately above &

below detail.

Ensure Clips are at least 100mm away from detail.

Allow free movement of sheets elsewhere.

SEAMING OPTIONS AT END LAP

Lap joints must be staggered between

500mm apart

5

0

m

m

8mm

5

0

m

m

20m

m

27m

m

9mm

6m

m

13mm

26m

m

Vieo Sheets cut on

site prior to jointing

RIVET ENDLAP DETAIL

Vieo Sheet Seaming Sequence

"Stage 1 Seam"

"Stage 2 Seam" (Aluminium Material Only)

ISSUE DATE: Sep 2014

SCALE: NTS

TITLE: Vieo Vertical Wall Covering (On Ply or OSB)

DWG NO: V10_VWC_TD_System

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: MP Checked by: PCl