presentation on fact device

15
Presentation On FACTS Device Presented To:Rethwan Faiz Faculty,Dept.EEE,AIUB

Upload: swarup-chowdhury-nirob

Post on 12-Apr-2017

87 views

Category:

Devices & Hardware


0 download

TRANSCRIPT

Page 1: Presentation On Fact Device

Presentation On

FACTS Device

Presented To:Rethwan Faiz

Faculty,Dept.EEE,AIUB

Page 2: Presentation On Fact Device

MEET WITH THE TEAM 1.Arin,Raisha Islam

2.Islam,Md.Mahmudul 3.Hasan,Md.Rakib

4.Sayed,Abdullah Abu5.Nazimuddowla,MD. 6.Chowdhury,Swarup

Page 3: Presentation On Fact Device

FACTS – WHAT IT IS??• FACTs is an acronym for Flexible AC Transmission Systems.

FACTs uses solid state switching devices to control power flow through a transmission network.

• FACTs idea was put forward by Prof. Hingorani of EPRI,USA in 1988.

• A line can be loaded up to its full thermal limit by FACTs.

• Power transfer can be increased through an old line by FACTs.

Page 4: Presentation On Fact Device

HISTORY OF FACTS

• Flexible AC Transmission Systems Technology (FACTs) was first proposed by the Dr. Narain G. Hingorani in 1988 of Electric Power Research Institute (EPRI),USA.

• The first FACTS installation was at the C.J. Slatt Substation near Arlington,Oregon.

• This is a 500 KV, 3-phase 60 Hz substation, and was developed by EPRI, the Bonneville Power Administration and General Electric Company.

Page 5: Presentation On Fact Device

OBJECTIVES OF FACTS• To increase the power transfer capability of transmission

systems. • To keep power flow over designated routes. • Secure loading of transmission lines nearer to their

thermal limits. • Prevention of cascading outages by contributing to

emergency control.• Damping of oscillations that can threaten security or limit

the useable line capacity.

Page 6: Presentation On Fact Device

FACTS CONCEPT

Page 7: Presentation On Fact Device

CLASSIFICATION OF FACTS The FACTS device can be classified in TWO ways: • Depending on the type of connection to the network 1.Serial Controller. 2.Derivation Controller. 3.Serial to Serial Controller. 4.Serial Derivation Controllers. • Depending on Technological Features the FACTS devices can be divided into

two generations: 1.First Generation- Uses thyristors with ignition controlled by door (SCR). 2.Second Generation- semiconductors with ignition and extinction controlled by door (GTO,IGBT,etc.)

Page 8: Presentation On Fact Device

SERIAL AND DERIVATION CONTROLLER

Serial Controllers: 1.Consist of a variable impedance as a coil. 2.Inject a serial tension to the line. 3.Consumes reactive power. Example:Serial Synchronous Static Compensator(SSSC)Controllers in Derivation:1.Consist of a variable impedance,variable source or a combination of both. 2.Inject current to the system in the point of connection. 3.Consumes reactive power. Example:Synchronous Static Compensator(STATCOM)

Page 9: Presentation On Fact Device

SERIAL-SERIAL AND SERIAL-DERIVATION CONTROLLERS

Serial-Serial Controllers: Combination of coordinated serial controllers in a multiline transmission system or can also be an unified controller. Example: Interline Power Flow Compensator(IPFC) Serial-Derivation Controllers: Combination of serial and derivations controllers separated, co-ordinately controlled. Example: Unified Power Flow Controller(UPFC)

Page 10: Presentation On Fact Device

GENERATION OF FACTS1.FIRST GENERATION OF FACTS 1.Static Compensator of VAR’s (SVC,TCR) 2.Thyristor Controlled Series Compensation (TCSC,TCSR) 3.Thyristor Controlled Phase Shifting Transformer(TCPST) 4.Thyristor Controlled Voltage Regulator(TCVR)2.SECOND GENERATION OF FACTS 1. Synchronous Static Compensator(STATCOM) 2. Static Synchronous Series Compensator(SSSC) 3. Unified Power Flow Controller(UPFC) 4. Interline Power Flow Controller(IPFC)

Page 11: Presentation On Fact Device

ADVANTAGES OF FACTS • Transmission Cost is minimized.• Smooth steady state and dynamic control.• Active damping of power oscillations.• Increase of reliability.• Improvement of system stability and voltage control.• Provide greater flexibility in sitting new generation. • Optimum power flow for certain objectives.

Page 12: Presentation On Fact Device

TECHNICAL BENEFITS OF FACTS

Page 13: Presentation On Fact Device

MAINTENANCE AND OPERATION• Maintenance of FACTS Devices: 1.Is minimal and similar to that required for shunt capacitors, reactors and transformers. 2.The amount of maintenance ranges from 150 to 250 man-hours per year.

* Operation of FACTS Devices: 1. Operated Automatically. 2. Can be done locally and remotely.

Page 14: Presentation On Fact Device

APPLICATIONS OF FACTS• Steady State Voltage Stability.• Power Flow Control.• Damping of power system oscillations.• Reducing generation costs.• HVDC link application.• Deregulated Power Systems.• Flicker Mitigation.

Page 15: Presentation On Fact Device

FUTURE ENHANCEMENTS OF FACTS

• Several FACTS devices have been introduced for various application world-wide.

• A member of new types of devices are in the stage of being introduced in practice.

• Many new devices are under research process, such as… HFC(Hybrid Flow Controller) RHFC(Rotary Hybrid Flow Controller) DPFC(Distributed Power Flow Controller) C-UPFC(Center Node) and Many More….