precision high energy liner implosion experiments – phelix

17
PHELIX Operated by Los Alamos National Security, LLC for the U.S. Department of Energy’s NNSA LAUR-09-05753 U N C L A S S I F I E D Precision High Energy Liner Implosion Experiments – PHELIX W.A. Reass, D.M. Baca, J.R. Griego R.E. Reinovsky, C.L. Rousculp, and P.J. Turchi Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545

Upload: leann

Post on 15-Jan-2016

37 views

Category:

Documents


0 download

DESCRIPTION

Precision High Energy Liner Implosion Experiments – PHELIX. W.A. Reass, D.M. Baca, J.R. Griego R.E. Reinovsky, C.L. Rousculp, and P.J. Turchi Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545. Outline. System Description Pulse Power Electrical Modeling Results - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Precision High Energy Liner Implosion Experiments –  PHELIX

PHELIX

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy’s NNSA LAUR-09-05753

U N C L A S S I F I E D

Precision High Energy LinerImplosion Experiments –

PHELIX

W.A. Reass, D.M. Baca, J.R. GriegoR.E. Reinovsky, C.L. Rousculp, and P.J. Turchi

Los Alamos National Laboratory, P.O. Box 1663,Los Alamos, NM 87545

Page 2: Precision High Energy Liner Implosion Experiments –  PHELIX

PHELIX

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy’s NNSA LAUR-09-05753

U N C L A S S I F I E D

Outline

• System Description• Pulse Power Electrical• Modeling Results• Marx Configuration• P-rad Facility• Transformer Design• System Configuration• Conclusion

Page 3: Precision High Energy Liner Implosion Experiments –  PHELIX

PHELIX

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy’s NNSA LAUR-09-05753

U N C L A S S I F I E D

System Description

• PHELIX is megajoule sized transformer coupled pulse power system– 8 marx modules

• System to drive hydrodynamic line experiments with a nominal current capability of 10 megamperes

– Will drive liners to 4 km/s

– Present budget limits us to ½ size for start up (5 megamperes, 480 kJ)

– Multi-framing capability with proton radiography at “LANSCE” accelerator

– Radial xradiography

• Marx banks utilize the “Atlas” plastic case 60 kV, 60 kJ capacitors and railgaps

• 4:1 multi-filar toroidal air-core transformer is mechanically part of a circular disc line

– Results in an attractive inductance budget

• Small reusable system very economical

Page 4: Precision High Energy Liner Implosion Experiments –  PHELIX

PHELIX

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy’s NNSA LAUR-09-05753

U N C L A S S I F I E D

Pulse Power Designs to be Conservative

• System to use proven Atlas Capacitors and Railgaps– Resistive damping to limit fault currents

• 120 kV operation in air was proven in Atlas test fixture– Many thousands (50,000) of successful shots

• System to interconnect with RG-217 cable and integral part of transformer

• Bank damping to use Reticulated Vitreous Carbon (RVC) Foam Resistors– Tested to 850 kA, 17 kA / cm2– Tested to 120 kV and 130 J / cc

• Capacitor Lifetime ~500 Shots with 55% reversal– System to operate ~40% reversal

Page 5: Precision High Energy Liner Implosion Experiments –  PHELIX

PHELIX

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy’s NNSA LAUR-09-05753

U N C L A S S I F I E D

Lp

Ip Is

Rp Rs

L1 L0

Ls

MHDMODULE

R=109

RAVEN MODELING

• Spice like network input file

• Couples to MHD module optimized for cylindrical hydrodynamics

• Lp and Ls are transformer inductances– Includes coupling and leakage

• Li and Lo are uncoupled inductances

• Better than 10 MA to “liner” for 960 kJ– For 8 parallel marx modules

– 120 kJ / 120 kV / module

– ~30% reversal

Page 6: Precision High Energy Liner Implosion Experiments –  PHELIX

PHELIX

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy’s NNSA LAUR-09-05753

U N C L A S S I F I E D

Extensive Capacitor Test Program Proved Lifetimes Better Than Predicted

LANL Qualification Life Test Data

No. of Units

Failed/ Good

Normal C/D

Cycles

Fault C/D

Cycles

Normalized Total

1 Failed 8150 81501 Good 7600 76001 Failed 6200 62002 Good 4000 300 46535 Good 4000 4000

• Nominal life is 2,400 shots @ 15% reversal

Page 7: Precision High Energy Liner Implosion Experiments –  PHELIX

PHELIX

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy’s NNSA LAUR-09-05753

U N C L A S S I F I E D

8 Marx Model Results Indicated Physics Goals Achieved with Adequate Damping

Bank Voltage (~55% reversal) Primary and Secondary Current (MA)

500 kA module current, 50 kA cable

~12.5 MA

Page 8: Precision High Energy Liner Implosion Experiments –  PHELIX

PHELIX

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy’s NNSA LAUR-09-05753

U N C L A S S I F I E D

VIEW OF DUAL MARX RACK

Switching / Charging Assemblies Output / Damping Resistor Assemblies

Page 9: Precision High Energy Liner Implosion Experiments –  PHELIX

PHELIX

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy’s NNSA LAUR-09-05753

U N C L A S S I F I E D

VIEW OF TRANSFORMER

Base Plate ~ 1M dia(secondary)

Post hole convolute

Secondary 18º segment

Primary 18º segment

Load Cassette

Page 10: Precision High Energy Liner Implosion Experiments –  PHELIX

PHELIX

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy’s NNSA LAUR-09-05753

U N C L A S S I F I E D

VIEW OF TRANSFORMER PRIMARY AND SECONDARY WINDING SEGMENTS

Secondary 18ºsegment

Contact lands

“Printed” Winding (Test) Assembly

“Printed” primary 18º segment

Page 11: Precision High Energy Liner Implosion Experiments –  PHELIX

PHELIX

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy’s NNSA LAUR-09-05753

U N C L A S S I F I E D

TRANSFORMER SUBASSEMBLIES

Detail of Power Flow Region

Page 12: Precision High Energy Liner Implosion Experiments –  PHELIX

PHELIX

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy’s NNSA LAUR-09-05753

U N C L A S S I F I E D

BUNKER TEST AREA

Page 13: Precision High Energy Liner Implosion Experiments –  PHELIX

PHELIX

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy’s NNSA LAUR-09-05753

U N C L A S S I F I E D

Compact Mechanical Design Accommodates P-rad Operational Requirements

• Capacitor bank, charging system, gas handling system, trigger system, control I/O, and hydrodynamic load on transportable trolley

• Supports for torus alignment to concrete floor

• P-rad beam-line installation when required

Page 14: Precision High Energy Liner Implosion Experiments –  PHELIX

PHELIX

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy’s NNSA LAUR-09-05753

U N C L A S S I F I E D

Aluminum Mechanical Enclosure Gives Required Electrical and Mechanical Safety

Page 15: Precision High Energy Liner Implosion Experiments –  PHELIX

PHELIX

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy’s NNSA LAUR-09-05753

U N C L A S S I F I E D

Entrance to LANSCE P-rad Facility

Page 16: Precision High Energy Liner Implosion Experiments –  PHELIX

PHELIX

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy’s NNSA LAUR-09-05753

U N C L A S S I F I E D

Remote Control

• Interface and remote I/O (All Fiber Optic)– Accelerator timing hand-shake

– Machine control / diagnostic hand-shake

• Trigger system

• Charging system

• Gas handling system

– Experimental diagnostics hand-shake

– Personnel protection interlocks

• Utility input power well filtered

Page 17: Precision High Energy Liner Implosion Experiments –  PHELIX

PHELIX

Operated by Los Alamos National Security, LLC for the U.S. Department of Energy’s NNSA LAUR-09-05753

U N C L A S S I F I E D

Conclusion

• Engineering and physics goals can be readily accomplished

• Systems fabrication with proven hardware and technique

• Design can meet all safety requirements

• Low operational costs will permit high shot rates

• With high shot rates and P-rad multi-framing capability, design tools can be more easily verified and validated

• PHELIX design is high performance, produces 10MA/MJ vs. 1MA/MJ for bigger machines such as ATLAS, SHIVA STAR, AND PEGASUS

• Experimentation to start this year