© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. HP Moonshot Maciej Grabowski Hewlett-Packard Polska Konsultant ds. Systemów Krytycznych Kraków, 2014-09-30 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

Upload: proidea

Post on 14-Jun-2015

239 views

Category:

Internet


2 download

DESCRIPTION

Maciej Grabowski – TBD Topic of Presentation: HP Moonshot Language: Polish Abstract: TBD

TRANSCRIPT

Page 1: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

HP MoonshotMaciej GrabowskiHewlett-Packard PolskaKonsultant ds. Systemów Krytycznych

Kraków, 2014-09-30

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

Page 2: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.2

HP Moonshot System: Game-changing innovationThe world’s first software-defined server

77%Less cost

80%Less space

97%Less complexity

89%Less energy

Converged Infrastructure for breakthrough efficiency and scale

• Shared power, cooling, networking, management and fabric  

• Up to 45 hot-plug server cartridges• Workload optimized

Source: HP internal analysis based on HP ProLiant Moonshot Server Cartridge, Intel Atom S1260 Processor

Software Defined Servers

Page 3: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.3

HP Moonshot: Precisely engineered, outcome designed

Application optimized tested and integrated for optimal performance

System-on-a-chip technology designed for maximum compute efficiency

Dense form factor hot-pluggable components and significantly less cabling

Industry unique approach delivers outstanding benefits

Highly flexible fabricssupporting a range of current and future capabilities

Page 4: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.4

Faster innovation and unprecedented efficiencyMoonshot architecture - the essential foundation for the New Style of IT

Scale97%Less complexity

89%Less energy

77%

Less cost

80%Less

space

18,000 Less cars per year (CO2

equivalent)

$195M Infrastructure savings per

year

EfficiencyMax

work/watt

Managed as one

Integratedfabrics

Hundreds of servers

(2) (3)

(1)

Source: HP internal analysis based on HP ProLiant Moonshot Server Cartridge, Intel Atom S1260 Processor

Page 5: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.5

Servers tailored and tuned for specific workloadsDelivering on the promise of software defined servers

Revolutionary cartridge design enabling business breakthroughs

Optimized

AdvancedDedicated Hosting

Web Front End

MemCache

Accelerators

Big Data

Desktop InfrastructureAnd more…

Workloads

77% Lower TCO for

dedicated hosting

Page 6: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.6

HP Moonshot 1500 Chassis front viewThe essential foundation for the New Style of IT

45 hot-plug cartridges

Compute, Storage, or Combinationx86 , ARM, or Accelerator

• Single-server = 45 servers per chassis

• Quad-server =180 servers per chassis

Dual low-latency switches• HP Moonshot-45G

Switch Module (45 x1Gb downlinks)

• HP Moonshot-180G Switch Module (180 x1Gb downlinks)

Page 7: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

Software defined servers for targeted solutions

ProLiant m700 Server

ProLiant Moonshot Server

ProLiant m300 Server

Page 8: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.8

Software defined servers optimized for workloadsISV reference architectures

ProLiant m700

ProLiant Moonshot Server

ProLiant m300

Hosted Desktop Infrastructure

Dynamic Web Serving

Hosting

Static Web Serving

Hosting

Page 9: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.9

HP ProLiant Moonshot Server specs

HP ProLiant Moonshot Server

Workload Dedicated hosting

CPU Intel® Atom Processor S1260, 2.0 GHz/2 core

Memory 8GB DDR3 ECC 1333MHz

Network Onboard NIC: Integrated dual-port 1Gb Ethernet NIC per CPU

Storage 500GB or 1TB HDD or SSD, non-hot-plug, small form factor

System configs

45 ProLiant Moonshot Servers in the HP Moonshot 1500 Chassis

Power Power < 19W AC under load per cartridge, including switch & chassis components

OS Canonical Ubuntu 12.04Red Hat Enterprise Linux 6.4SUSE Linux Enterprise Server 11 SP2

First software defined server based on Intel® Atom Processor S1260

TM

TM

Page 10: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.10

Moonshot powers HP.com4Cache

16 HTTP Apache

16Download files

46 servers ->6 chassis23->6 Racks

138kW-> 3(6)kW Power total< 1 Rack/data center

Browsing: www.hp.com (HP’s web gateway)Downloads: ftp.hp.com (driver updates )

100%www.hp.com

300Mhits per day

94%Less power

89%Less space

(1)

100%ftp.hp.com

8Load balancing

Page 11: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.11

HP ProLiant m300 Server Cartridge specs

HP ProLiant m300 Server CartridgeWORKLOADS Web/App Server, Mobile Content Delivery Network, Analytics

CPU (1) Intel® Atom™ Processor C2750 , 2.4 GHz / 8 core

MEMORY (4) DIMMS Total – Total of 32G each 8GB, 1600MHz, DDR3 UDIMM SO-DIMM ECC

NETWORK Integrated NIC: dual port 1GbE per CPUSwitch module: (45) 1GbE DownlinksUplink module: (6) 10GbE SFP+ ports

STORAGE (1) Small form factor HDD - 500GB, 1TB or 240G SSD

BOOT 1) Direct From Drive 2) Network 3) Local Boot from NAND

SYSTEM CONFIGS (45) HP ProLiant m300 Server Cartridges

POWER Cartridge: <30W

OS Ubuntu 13.10, RHEL 6.5, SLES 11 SP3, Windows Server 2012, WS 2012 R2

Page 12: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

Warstwa sieciowa

Page 13: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.13

Highly flexible fabrics Supporting a range of current and future capabilities

Traffic isolation and stacking for resiliencywith dual low-latency switches

Economical and flexible storagewith shared storage lanes

Multiple servers managed as one platformwith dedicated iLO network

Integrated cluster fabricwith point-to-point connectivity

$

8 Lanes

Page 14: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.14

Management fabricMultiple servers managed as one platform with dedicated iLO network

• HP Moonshot 1500 Chassis Management module aggregates all to a common set of management interfaces

• Single Ethernet port gateway

• IPMI and Serial Console for each server

• True out-of-band firmware update services

• SL-APM Rack Management spans rack or multiple racks

SC SCSC

SCSC

SC SCMgmt.Hub

SwitchingFabric

ManagementPort

CoolingSub-system

Power Sub-system

StorageBackup or cartridge

HP Moonshot 1500 Chassis Management module

SC: Satellite Controller

Page 15: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.15

Radial Communication Fabric

• Each 45XGc switch provides one 10GbE link to each server bay, two switch modules deployed to achieve redundancy.

• Each server has a dual-port NIC, one port going to each switch.

• Switch Module B is optional, but without it, the second port on each server will have no connectivity.

Page 16: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.16

Storage Fabric

• Five proximity clusters, 9 cartridges each.

• 3 x 3 cluster layout.

• 12 Gb SAS/SATA links / 10 Gb line speed.

• Slicing (8) driver for storage.

$

Page 17: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.17

Cluster FabricIntegrated cluster fabric with point-to-point connectivity (2D Torus)

• High-speed communication lanes between servers

• Ring fabric allows minimum and direct card to card communication path

• Suitable for applications where efficient localized traffic is beneficial

• Cross shaped with range of 4Ring fabric is SoC vendor specific, homogeneous and stays inside the chassis

16 x 10.3 GBaud Lanes

4 x 10 GBaud Lanes

Cartridges

Page 18: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.18

HP Moonshot Switch Family

Moonshot-45G• Shipping Now• 45 1Gb downlink

ports• 6 10Gb uplink ports

(SFP+)• Oversubscription:

None• Layer 2, Layer 3,

Routing, QoS, Stacking, Management (CLI, SNMP, sFlow)

• No license keys• 50 Watts, max load,

including uplink module

Moonshot-180G• Shipping Now• 180 1Gb downlink

ports• 4 40Gb uplink ports

(QSFP+)• 16 10Gb uplink ports

(SFP+)• Oversubscription: 1.1

: 1• Layer 2, Layer 3,

Routing, QoS, Stacking, Management (CLI, SNMP, sFlow)

• No license keys• 210 Watts, max load,

including uplink module

Hyperscale

Moonshot-45XGc• September 2014• 45 10Gb downlink ports• 4 40Gb uplink ports (QSFP+)• 16 10Gb uplink ports (SFP+)• Oversubscription: 3 : 1• Comware 7• Layer 2, Layer 3, Routing, QoS,

IPv6, OpenFlow 1.3, Precision Time Protocol, IRF stacking, Management (CLI, SNMP, sFlow)

• No license keys• 73 Watts, max load, including

uplink module

Hyperscale + Enterprise

Page 19: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.19

MOONSHOT SWITCH MODULE COMPARISON

45XGc 45G 180G

Uplink Ports 4*40GbE 6*10GbE 4x40GbE

Downlink Ports 45*10GbE 45*1GbE 180*1GbE

Uplink Bandwidth 160Gbps 160Gbps 160Gbps

Oversubscription 3:1 No 1.1:1

Memory/Flash 2GB/512MB 2GB/128MB 2GB/512MB

Stackable Yes – 4 members IRF, 10 in future

Yes - 4 Yes - 2

MAC/VLANs 128K/4K 128K/4K 128K/4K

IP routing table 16K 12K 12K

Packet Buffer 9MB 9MB 22MB

TRILL/FCoE/EVB Yes/Yes/Yes No/No/No No/No/No

Full Layer 3/Full IPv6 Yes No/No No/No

Page 20: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.20

SOFTWARE FEATURES

L2 Switching:MAC AddressSpanning TreeTRILLLink AggregationVLANVLAN MappingStorm ControlIGMP Snooping

IPv4 Routing:RIP/OSPF/BGPv4VRRP/ECMPRoute PolicyPolicy-based RoutingPIM-DM/PIM-SM/PIM-SSMIGMP v1/v2/v3Multicast VlanARPDHCP

QoS and ACL:CAR/GTS/LRSP/WDRR/WFQ802.1P/DSCPRemark/RedirectWREDUser ProfileTime RangeACL (L2 to L4)

IPv6 Routing:IPv6 static routes/RIPng/OSPFv3/DHCPv6

Security:Hierarchical management/password protectionRadius/TACACS+SSH2.0Port IsolationIP-MAC-Port bindingIP Source guard

Page 21: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.21

SOFTWARE FEATURES (Cont.)

Management:Telnet/ConsoleSNMPIPv6 managementsFlowLLDPSyslogNTPIRF

OAM & Maintenance:DebugPing/TracertNQATrack802.1ag(CFM)/802.3ah(OAM)DLDP

Data Center Bridging:DCBX(802.1Qaz)ETS(802.1Qaz)PFC(802.1Qbb)

Moonshot:iLO Chassis Manager

Other:FCoEStandards-based VEPAPAN/SPAN/RSPAN (Mirroring)Flow ControlStore and Forward/Cut-throughEVBOpenFlow v1.3.1

Page 22: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.22

COMWARE V7 HIGHLIGHTS

Latest Generation Architecture

• Full distribution−Distributed route computing,

distributed service processing

• Multi-Threaded/Processor−Multi-process computing makes full

use of multi-core’s parallel capabilities.

−SMP (symmetrical multi-processing) Model

• High-availability Architecture−More stable, Higher performance

−Zero Service Disruption, HA, IRF

Page 23: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

Warstwa usługowa

Page 24: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.24

Introducing HP Cloud OS for Moonshot

Based on OpenStack® technology

Open and extensible

Enables hybrid delivery

HP Cloud OS

Unparalleled power efficiency

Workload optimized

Breakthrough scale

HP Moonshot

Speed bare-metal efficiency

Simplify cloud service

delivery

Enhance service lifecycle

management

HP Cloud OSfor

Moonshot

Cloud management software designed for fast cloud deployment on Moonshot

The OpenStack  Word Mark and OpenStack Logo are either registered trademarks/service marks or trademarks/service marks of the OpenStack Foundation, in the United States and other countries and are used with the OpenStack Foundation's permission. We are not affiliated with, endorsed or sponsored by the OpenStack Foundation, or the OpenStack community.

Page 25: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.25

Seamless switching from standard instance management to chassis view

Moonshot Chassis Manager Integrated into Horizon

Page 26: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.26

Moonshot Chassis Manager (cartridge view)

Page 27: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.27

Moonshot Chassis Manager (node view)

Page 28: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.28

Workload Topology Designer Integrated into Horizon

Page 29: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.29

The correct cartridges are chosen based on the workload requirements

Dynamic Workload Placement

Atom x861x8C/2.4GHz•16GB

Avoton

Dynamic webHosting

Most analyticsBig Data, NoSQL,

MemcacheD

Cartridge 2

Atom x861x2C/2GHz•8GB

Centerton

Static webEntry hosting

Light analyticsNoSQL

database

Cartridge 1

Requires Dynamic Web

Requires Static Web

Cloud OS Distribution

Network (CODN)

Page 30: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

Pytania?

Page 31: PLNOG 13: Maciej Grabowski: HP Moonshot

© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.31

Optimize your application

performance

HP Moonshot System Accelerate

business innovation

Enabling you to be more competitive

A system that truly fits the workload it is running

Realize breakthrough

economics

Redefining the economics of your data

center

HP Moonshot