hp moonshot server

27
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Rethink workload defined Server: HP Moonshot Designed for the data center, built for the planet © Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

Upload: -

Post on 24-Jan-2018

152 views

Category:

Technology


1 download

TRANSCRIPT

Page 1: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

Rethink workload defined Server: HP MoonshotDesigned for the data center, built for the planet

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

Page 2: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.2

Contents.

1. Moonshot Overview

2. Moonshot Cartridges detail

Page 3: Hp moonshot Server

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

HP Proliant Moonshot Overview

Page 4: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.4

2014

124,000 MIPS

By 2020

1989

20 MIPs

Cloud

Mobility

Security

Big Data

1972

.004 MIPS

인터넷접속장비및웹트래픽의폭발적증가현재 IT인프라는새로운비즈니스를감당하기에버거움

30

Billion

(300억)

40

Trillion GB

(40조)

… for 8

Billion

(80억)

10

Million

(1천만)

DATA

(1)

(2)

(3)

Devices

Mobile

Apps

(4)

(1) IDC Directions 2013: Why the Datacenter of the Future Will Leverage a Converged Infrastructure, March 2013, Matt Eastwood ; (2) & (3) IDC Predictions 2012: Competing for 2020, Document 231720, December 2011, Frank Gens; (4)

http://en.wikipedia.org

Page 5: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.5

현재서버는미래 IT 요구사항에적합하지않음전력, 상면, 비용및복잡성에서미래에지속불가능함

New Style of ITTraditional IT

수백만개의 성능수십억개의기기/사용자 비지니스응용프로그램

특화되고무한한인프라

가상화및예측가능한인프라

수백개의 지원수천개의기기/사용자 비지니스응용프로그램

Today’s

ServersPer Year

100-200 억불Datacenter build costs

8 to 10New power plants

200만US Homes of power

used

(1) (2) (3)

Source: HP internal research

Page 6: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.6

HP 혁신의역사및리더쉽새로운시장및비즈니스기회를리딩해왔습니다.

x86

블래이드x86

랙서버 1stx86

SystemPro ProLiant BladeSystem

HP 엔지니어링

Moonshot

업무최적화서버

한계를뛰어넘는효율성과확장성을위한Workload Defined Server: Moonshot

• 전원, 냉각, 네트워크, 관리기능공유• 최대 45개의핫플러그서버카트리지• 업무별최적화된성능제공

업무최적화서버

Page 7: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.7

혁신을위한파트너프로그램Moonshot 시스템은새로운개념의혁신, 솔루션및지원을약속합니다.

HP Pathfinder

Innovation

Ecosystem

Moonshot

Concierge

Support

Customer

Need

Analyze

Application

Optimize

Server

Launch

Solutions

4x the Solutions

3x Faster Time to

Innovation

Leading

technology

partnerships

HP Discovery

Lab

Service &

Consulting

Acquire on

your terms$

Solution Builder

program

Community

Expertise

Reference

Architecture

s

Page 8: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

HP Moonshot system

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.8

Page 9: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.9

HP Moonshot 1500 Chassis 전면새로운형태의 IT에대한기반

hot-plug 카트리지 45대

• Single-server = 샤시당 45대독립서버제공

• Quad-server =샤시당 180대독립서버제공

low-latency 스위치 2대• HP Moonshot-45G Switch

Module (45 x1Gb 다운링크)

• HP Moonshot-180G Switch

Module (180 x1Gb 다운링크)

• HP Moonshot-45xGc Switch

Module (45 x10Gb

다운링크)

Page 10: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.10

HP Moonshot 1500 Chassis 후면새로운형태의 IT에대한기반

HP 공통전원공급기

이중화된 hot-plug 팬모듈 5개

Dual Network Uplinks• HP Moonshot-6SFP 업링크모듈 (6 x10Gb Stackable

Uplinks)

• HP Moonshot-4SFP 업링크모듈 (4 x40Gb Stackable

Uplinks)

HP Moonshot 1500 Chassis

관리모듈

Page 11: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.11

네트워크 Fabric 연결옵션두대의 low-latency 스위치를통해트래픽분리또는네트워크이중화기능제공

Switch B

Switch A

Servers 1-45

Uplink module B

Uplink Module A

Single servers45 ports

Quad servers 180 ports

Switch B

Switch A

Servers 1-45

Uplink module B

Uplink Module A

Page 12: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.12

Management fabric여러대의서버를하나의 iLO 네트워크를통해단일플랫폼으로관리

• HP Moonshot 1500 Chassis 관리모듈은일반적인관리인터페이스를통합제공

• 단일 Ethernet 포트사용

• 각서버에 IPMI 및 Serial Console

제공

• 완벽히분리된펌웨어업그레이드서비스제공

• SL-APM 랙관리기능제공

SC SCSC

SCSC

SC SCMgmt.

Hub

Switching

Fabric

Management

PortCooling

Sub-system

Power

Sub-system

Storage

Backup or

cartridge

HP

Moonshot

1500

Chassis

Managemen

t module

SC: Satellite Controller

Page 13: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.13

HP Insight Cluster Management Utility (CMU)카트리지나외부에서동작가능한리눅스클러스터관리도구

배포

모니터링

제어

빠른탐색및복제제공트리구조배포및확장기능제공

전체서버상태즉시파악화면장애화면확대기능제공커스터마이징가능

GUI 및 CLI 옵션제공쉽고빠른설치지원

Available NOW!

Page 14: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.14

카트리지서버상세업무목적별최적의 CPU, memory, storage, networking 제공

Web infrastructure, dedicated

hosting, distributed analytics, NoSQL

databases

Video transcoding, gaming, application

delivery, extreme file transfer

Memory caches, in-memory

analytics, science and engineering

applications

Hosted desktop infrastructure,

gaming, content distribution network

(CDN)

Real-time data processing, complex

event processing, IP transcoding

Typical workloadsCompute StorageNetworking Specialized

cores

MemoryProLiant

m300

m350

m400

m700

m710

m800

Density

Web hosting, distributed analytics

ARM 64bit

8

cores/SoC

Dual port

10GbE

/CPU

N/A 64GB 45/4.3

U

180/4.3U

180/4.3U

45/4.3

U

45/4.3

U

180/4.3U

Dual port

10GbE

/CPU

Dual port

1GbE

/CPU

Dual port

1GbE

/CPU

Dual port

1GbE

/CPU

Dual port

1GbE

/CPU +

2D Torus

Local SSD

(NGFF/m.2)

ARM A15

4 cores /

SoC

32GB

8GB/S

oC

C66x DSP

8 cores/

SoC

GPU Iris

Pro +

128MB

eDDR

Xeon E3

4 cores/SoCLocal SSD

(NGFF/m.2)32GB

Atom™ C2750

8 core/SocN/A

N/AAtom™ C2730

8 core/SoC64GB

16GB/S

oC

Local SSD

(NGFF/m.2)

SFF HDD or

SSD32GB

Opteron™ X2150

4 core /SoC32GB

8GB/S

oC

4 x 64GB

iSSDGPU

128 cores/SoC

Page 15: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

HP Moonshot ServerCartridge Details

ProLiant m700

Server

ProLiant

Moonshot

Server

(m100)

ProLiant m300

Server

Page 16: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.16

HP ProLiant m300 서버카트리지소개Web/App Server, Big Data Analytics 용

TM

Intel® Atom Processor

C2750 2.4 GHz/8 core

TM

32G Max Memory

(4) 8GB DDR3 ECC

1600MHz

(2 on front & 2 on back)

500GB or 1TB HDD or SSD,

non-hot-plug, small form factor

x 45 hot-plug servers per chassis

13.10

Enterprise

Linux 6.4

Linux Enterprise

Server 11 SP2

Windows

Server 2012 R2

Page 17: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. HP Confidential.17

기존의 1u 1P 서버HP Moonshot System

45 ProLiant m300 servers

ProLiant m300 서버카트리지도입효과Web/App/Big Data 분석업무에최적화

80% 낮은전력소모91% 적은상면사용97% 적은케이블 TCO 절감

50%

45 1U 1P 서버

1 랙 (47u 랙)

4 Kwatts 전력

45 ProLiant m300 서버

1 샤시 (4.3u)

0.8 Kwatts 전력

Page 18: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. HP Confidential.18

Moonshot powers HP.com

6Cache

16 HTTP Apache

16Download files

6 대의 Moonshot 샤시< 6kW 총전력사용

< 1 랙이하Browsing: www.hp.com (HP’s web gateway)

Downloads: ftp.hp.com (driver updates )

100%www.hp.com

300만건일일방문수

94%낮은전력소모

89%적은상면사용

(1)

100%ftp.hp.com

Page 19: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.19

HP ProLiant m700 카트리지소개Hosted Desktop Infrastructure 전용

4개의 APU SoC

4개의 8GB DDR3 ECC

1600MHz 메모리

샤시당 45개의 hot-plug 카트리지(샤시당 180대의데스크탑수용)

iLO 관리프로세서

4개의 32Gb iSSD 또는4개의 64Gb iSSD

*APU = Accelerated processing unit

Page 20: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.20

HP만이유일하게완벽한원격데스크탑제품군제공

성능및가격

세션/응용프로그램

가상화

가상데스크탑(VDI)

높은그래픽성능이

제공되는가상데스크탑

밀도High

High

Client

Devices

단순사용자

지식사용자

일반사용자 고급사용자

워크스테이션사용자

HP Moonshot

m700

(HDI)

Page 21: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

Moonshot Leap 4 Cartridges

Page 22: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.22

CPU (4) 13W soldered down Intel Atom Avoton / 8 core / 1.7GHz

MEMORY Total of 16GB per CPU – or 2GB/core

(4) Socketed DIMMS – each 8GB, 1600MHz, DDR3 SO-DIMM, ECC

(4) Embedded DRAM – each 8GB, 1600MHz, DDR3 SO-DIMM, ECC

NETWORK Integrated NIC: dual port 2.5GbE per CPU. (Dialed down to 1GbE)

STORAGE NAND Mezz for local Boot – 64G per CPU or 32G per CPU

BOOT 1) Network 2) Local Boot from NAND Mezz

SYSTEM CONFIGS 45 Scott 4 Cartridges, 30 Scott4 Cartridges, 15 Scott4 Cartridges.

POWER Measured Max 60W per Cartridge.

OS Ubuntu 12.04.4, RHEL 6.5, SLES 11 SP3+PLDP for 1GB NIC,

Windows Server 2012, Windows Server 2012 R2

HP ProLiant m350 Moonshot Cartridge

Limited Availablility August 2014

Managed hosting, 병렬연산, HTC 업무용도

180 Servers per Chassis (15A)

Page 23: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.23

HP Proliant m710 Moonshot Cartridge

CPU 47W soldered down Intel Xeon E3-1284Lv3 4-core 1.8Ghz Haswell (all-core

turbo 2.4Ghz)

MEMORY 4 LV S0DIMM (Non- ECC) plus 8 ECC DRAM down. Total 32GB Max.

NETWORK Integrated NIC: Dual port 10GbE Mellanox CX3 MT27518.

STORAGE Local boot / SATA or PCIe NGFF (M.2).

BOOT 1) Network.

2) Local Boot via SATA or PCIe NGFF (M.2).

SYSTEM CONFIGS a) 45 Anders Cartridges.

b) 15 Anders Cartridges

POWER Cartridge: <70W @ 75% loading

Form Factor Single Wide, Single slot - Gemini Module (6.8” X 6.1”)

OS (SW) Ubuntu 14.04, RHEL 6.5,7.0 w/KVM, SLES 11 SP3 w/KISO/KVM, Windows

Server 2012 R2, CentOS 6.5, 7.0

Launching September 2014

Media Transcoding & Big Data (Investigating), XenApp

Haswell CPU Core + Crystalwell GPU Core

Page 24: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.24

HP ProLiant m400 Moonshot Cartridge

CPU (1) Applied Micro “Storm” 64-bit ARM , 2.4 GHz / 8 core

MEMORY (4 or 8) DIMMS – Total of 32 or 64GB

each 8GB, 1600MHz, DDR3 UDIMM SO-DIMM ECC

NETWORK Mellanox Connect X3 NIC: dual-port 10GbE

Switch module: (45) 10GbE Downlinks “ComWolff-1X”

Uplink module: (4) 40GbE SFP+ ports “Rook40”

STORAGE (0 or 1) M.2 80mm Flash Module - 120GB, 240GB or 480GB

ROM HP BIOS, uBoot, Headless, no video, no USB

BOOT 1) Direct From M.2 Flash 2) Network 3) software iSCSI (once OS

Supports)

SYSTEM CONFIGS (15, 30, or 45) HP ProLiant m400 Server Cartridges

POWER Processor: 37 – 43W max

Cartridge: <65W typical, 85W TDP with 8 DIMMs

OS Ubuntu 14.04 Preinstalled

2.88TB of memory, 21.6TB of flash storage Per Chassis

Memcached, NoSQL(MongoDB, Cassandra)

Page 25: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.25

HP ProLiant m800 Server Cartridge

CPU (4) TI 66AK2H12 = (4) ARM A15 cores + (8) C66x DSP cores/processor,

1.0GHz

MEMORY (4) DIMMS – Total of 32GB

8GB/CPU, 1600MHz, DDR3 UDIMM SO-DIMM ECC

NETWORK Integrated NIC: dual port 1GbE per CPI

Switch: HP Moonshot-180G Switch Module

Uplink Module: HP Moonshot-4QSFP+ Uplink Module

STORAGE Via mezzanine: 32GB or 64GB m.2 (2242) per SoC

BOOT 1) Network

2) Local storage via NGFF (32GB or 64GB)

SYSTEM CONFIGS (45) HP ProLiant m800 Server Cartridges w/ 32GB m.2 NGFF

POWER Cartridge: ~70W typical (Preliminary)

OS + DSP tool Ubuntu 13.10 + TI MCSDK (preinstalled)

Launching September 2014

VoIP/LTE, Voice Transcoding, Seismic processing(지질분석), 실시간신호처리4 ARM A15 Cores + 8 TI DSP Cores

Page 26: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.26

The HP Discovery Lab Network

Investigate, test, and benchmark

applications in a secure and

confidential environment

Houston,

Texas

Purdue

University

Indiana

(education only)

Grenoble,

France

Singapore

New: Purdue and Singapore

Page 27: Hp moonshot Server

© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

감사합니다.

Key Takeaway of HP Moonshot

1. 분산/병렬환경에최적화2. 업무목적별로특화3. 도입비용이아닌 TCO 관점의접근