Page 1: Performing Operational Clash Detection - Bentley · 2015-11-16 · High DY displacement = -4.214” in at 12F (Possible clash between 2 pipes) Export to DGN using (File > Export >

1 | P a g e

Performing Operational Clash Detection

Clash Detection Workflow

Page 2: Performing Operational Clash Detection - Bentley · 2015-11-16 · High DY displacement = -4.214” in at 12F (Possible clash between 2 pipes) Export to DGN using (File > Export >

2 | P a g e

Page 3: Performing Operational Clash Detection - Bentley · 2015-11-16 · High DY displacement = -4.214” in at 12F (Possible clash between 2 pipes) Export to DGN using (File > Export >

3 | P a g e

Open AutoPIPE Model

Open Model “PIPMALL1A_STR_FINAL_V94_SMALL_Z.DAT”

Page 4: Performing Operational Clash Detection - Bentley · 2015-11-16 · High DY displacement = -4.214” in at 12F (Possible clash between 2 pipes) Export to DGN using (File > Export >

4 | P a g e

Analyze for Gravity, thermal, 4 seis

mic loadings

Load > Static Analysis Sets

Analyze > Static

Any of the AutoPIPE non-code combinations can be displayed on screen and exported to Bentley Navigator for

check Clash detection

Tools > Combinations (Select non-code combinations)

Page 5: Performing Operational Clash Detection - Bentley · 2015-11-16 · High DY displacement = -4.214” in at 12F (Possible clash between 2 pipes) Export to DGN using (File > Export >

5 | P a g e

Generate an output report to determine areas of maximum displacement

Result > Output Report

Page 6: Performing Operational Clash Detection - Bentley · 2015-11-16 · High DY displacement = -4.214” in at 12F (Possible clash between 2 pipes) Export to DGN using (File > Export >

6 | P a g e

Check the maximum displacements in X, Y, Z directions as possible areas of clashes

View displacement plot at point C12F for GRT1E3{1} load combination

Page 7: Performing Operational Clash Detection - Bentley · 2015-11-16 · High DY displacement = -4.214” in at 12F (Possible clash between 2 pipes) Export to DGN using (File > Export >

7 | P a g e

High DY displacement = -4.214” in at C12F (Possible clash between 2 pipes)

Export to DGN using (File > Export > DGN Model (*.dgn)) Hint: Show the insulation defined in the model (View > Show Options > Pipe Insulation) to include the additional

thickness when exporting for clash detection.

Page 8: Performing Operational Clash Detection - Bentley · 2015-11-16 · High DY displacement = -4.214” in at 12F (Possible clash between 2 pipes) Export to DGN using (File > Export >

8 | P a g e

Select ‘Deflected Model Graphics’ and choose the GRT1E3{1} load combination

DGN file is created in same folder as the DAT model file

Page 9: Performing Operational Clash Detection - Bentley · 2015-11-16 · High DY displacement = -4.214” in at 12F (Possible clash between 2 pipes) Export to DGN using (File > Export >

9 | P a g e

Page 10: Performing Operational Clash Detection - Bentley · 2015-11-16 · High DY displacement = -4.214” in at 12F (Possible clash between 2 pipes) Export to DGN using (File > Export >

10 | P a g e

Open DGN model in Navigator and Perform Clash Detection Microstation or Navigator can be used to run clash detection

Open Navigator and Select DGN Model “PIPMALL1A_STR_FINAL_V94_SMALL_Z.dgn”

Page 11: Performing Operational Clash Detection - Bentley · 2015-11-16 · High DY displacement = -4.214” in at 12F (Possible clash between 2 pipes) Export to DGN using (File > Export >

11 | P a g e

Run the CLASH detection

Define a new job called “Clash1”

Page 12: Performing Operational Clash Detection - Bentley · 2015-11-16 · High DY displacement = -4.214” in at 12F (Possible clash between 2 pipes) Export to DGN using (File > Export >

12 | P a g e

Job > Advanced Settings

Criteria TAB and Select “Levels” Task

Click on 2 levels

“SEG_C_STRESS_MESH_DEFLECTED” and “SEG_D_STRESS_MESH_DEFLECTED”

And drag to Set A box

Note: Alternatively, select the items from the Plant model you want to clash with, e.g. Structure, Equipment,

etc., and add them to Set A (Red). The deflected AutoPIPE piping models can be selected for Set B (Blue) from

the referenced-in stress models.

Select the “Self check”

Under Rules, define a new Rule “Suppress clashes within the same level” i.e. on same segment or line number

Page 13: Performing Operational Clash Detection - Bentley · 2015-11-16 · High DY displacement = -4.214” in at 12F (Possible clash between 2 pipes) Export to DGN using (File > Export >

13 | P a g e

Click “Process” button

Five (5) hard clashes are found

Page 14: Performing Operational Clash Detection - Bentley · 2015-11-16 · High DY displacement = -4.214” in at 12F (Possible clash between 2 pipes) Export to DGN using (File > Export >

14 | P a g e

Page 15: Performing Operational Clash Detection - Bentley · 2015-11-16 · High DY displacement = -4.214” in at 12F (Possible clash between 2 pipes) Export to DGN using (File > Export >

15 | P a g e

Page 16: Performing Operational Clash Detection - Bentley · 2015-11-16 · High DY displacement = -4.214” in at 12F (Possible clash between 2 pipes) Export to DGN using (File > Export >

16 | P a g e

To Create a Clash Markup Create a markup for clash 2, click on the markup icon

A Markup name “Clash2_Clash1” is created

Or click the Task “Create Clash Markup”

Select from the menu Review > Markup > Markups dialog

Page 17: Performing Operational Clash Detection - Bentley · 2015-11-16 · High DY displacement = -4.214” in at 12F (Possible clash between 2 pipes) Export to DGN using (File > Export >

17 | P a g e

Add a new comment

Page 18: Performing Operational Clash Detection - Bentley · 2015-11-16 · High DY displacement = -4.214” in at 12F (Possible clash between 2 pipes) Export to DGN using (File > Export >

18 | P a g e

Double click the “Clash2_Clash1” row to redline the markup

Page 19: Performing Operational Clash Detection - Bentley · 2015-11-16 · High DY displacement = -4.214” in at 12F (Possible clash between 2 pipes) Export to DGN using (File > Export >

19 | P a g e

Click the “Print to PDF” button to create a markup PDF