2
www.tridonic.com 1 Subject to change without notice. Data sheet 01/12-400-4 Electronic transformers for low-voltage halogen lamps Mounting Product description Independent device with integrated cable clamp and terminal cover Dimming range 1 to 100 % Control via 1...10 V interface For emergency lighting systems as per EN 50172 Short-circuit shutdown feature with automatic restart With soft start Overtemperature and overload protection by reducing power and automatic restart 6-pole terminal on secondary side Cage-type screw terminal Practical individual packaging with assembly instructions Rapid installation of cable clamp and terminal cover, no tool required Not suitable for operation with MR16 LED bulbs Technical data Protection class II Type of protection IP20 Mains frequency 0 / 50 / 60 Hz Efficiency > 94 % λ > 0.9 Max. cable length secondary 2 m È Standards, page 2 Wiring diagrams and installation examples, page 2 TE-U 1...10 V sc, 20 – 105 VA 230 – 240/12 V 0/50/60 Hz Dimming 1...10 V Ordering data Lamp wattage Dimensions LxWxH Distance between mounting holes (D) Dimming Type Article number 20 – 105 VA 167 x 42 x 31 mm 143 – 148 mm 1...10 V DC or potentiometer 100 kΩ log. TE 0105 U 86457964 Packaging: 20 pieces/carton, 800 pieces/pallet Specific technical data Type Rated supply voltage AC Rated supply voltage DC Rated current (at 230 V 50 Hz) 1 Secondary voltage 1 DC lamp output Operating frequency Ambient temperature ta Max. casing temperature Soft-start Weight Output terminal TE 0105 U 230 – 240 V 230 – 240 V 0.45 A 11.9 V 70 % 32 kHz -25 ... +55 °C 90 °C yes 0.18 kg 6-pin 1 Valid at 100 % dimming level. PHASED OUT

Upload: others

Post on 26-Mar-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: OUT - Tridonic GmbH & Co KG• Potentiometer 100 kΩ log. Control input (1–10 V) The TE-0105 U can be controlled either by an analogue 1 – 10 VDC signal or potentiometer 100 kΩ

www.tridonic.com 1Subject to change without notice.

Data sheet 01/12-400-4

Electronic transformers for low-voltage halogen lampsMounting

Product description

• Independent device with integrated cable clamp and terminal cover

•Dimming range 1 to 100 %

•Control via 1...10 V interface

•For emergency lighting systems as per EN 50172

•Short-circuit shutdown feature with automatic restart

•With soft start

•Overtemperature and overload protection

by reducing power and automatic restart

•6-pole terminal on secondary side

•Cage-type screw terminal

•Practical individual packaging with assembly instructions

•Rapid installation of cable clamp and terminal cover,

no tool required

•Not suitable for operation with MR16 LED bulbs

Technical dataProtection class II

Type of protection IP20

Mains frequency 0 / 50 / 60 Hz

Efficiency > 94 %

λ > 0.9

Max. cable length secondary 2 m

ÈStandards, page 2

Wiring diagrams and installation examples, page 2

TE-U 1...10 V sc, 20 – 105 VA 230 – 240/12 V 0/50/60 HzDimming 1...10 V

Ordering dataLamp wattage

Dimensions LxWxH

Distance between mounting holes (D)

Dimming Type Article number

20 – 105 VA 167 x 42 x 31 mm 143 – 148 mm1...10 V DCor potentiometer 100 kΩ log.

TE 0105 U 86457964

Packaging: 20 pieces/carton, 800 pieces/pallet

Specific technical dataType Rated supply

voltage ACRated supplyvoltage DC

Rated current(at 230 V 50 Hz)1

Secondary voltage1

DC lampoutput

Operating frequency

Ambienttemperature ta

Max. casing temperature

Soft-start Weight Outputterminal

TE 0105 U 230 – 240 V 230 – 240 V 0.45 A 11.9 V 70 % 32 kHz -25 ... +55 °C 90 °C yes 0.18 kg 6-pin1 Valid at 100 % dimming level.

PHASED OUT

Page 2: OUT - Tridonic GmbH & Co KG• Potentiometer 100 kΩ log. Control input (1–10 V) The TE-0105 U can be controlled either by an analogue 1 – 10 VDC signal or potentiometer 100 kΩ

www.tridonic.com 2Subject to change without notice.

Data sheet 01/12-400-4

Electronic transformers for low-voltage halogen lampsMounting

StandardsEN 55015EN 61000-3-2EN 61047EN 61347-2-2EN 61547

DimmingDimming range 1 % to 100 %Analogue control by: •1–10VDC

•Potentiometer100kΩ log.

Control input (1–10 V)The TE-0105 U can be controlled either by an analogue 1 – 10 VDC signal orpotentiometer 100 kΩ.A dimming characteristic adapted to the eye sensitivity can be achieved by using a logarithmic potentiometer.The device cannot turned on or off by the control input 1 – 10 V.

Light output level in DC operationThe light level in DC operation is set to 70 %.In DC operation dimming is not possible.

Installation instructions

Maximum loading of automatic circuit breakersAutomatic circuit breaker type C10 C13 C16 C20

Installation Ø 1.5 mm2 1.5 mm2 1.5 mm2 2.5 mm2

TE-0105 U 1–10 V sc 20 26 32 40

A A B

A

A 25 mm / B 100 mm

ta: 55°C max.

1812 6

H03VV-FH05VV-F

max.:

1 x 2,5

2 x 1,5

3–10 mm

NL

max. 105 VA

1–10 V

max. 2 m

+

654321–

TE-U0105 VA

NL

max. 105 VA

max. 2 m

+

654321–

TE-U0105 VA

control by electronic potentiometer

control by external1–10 V signal

A A B

A

A 25 mm / B 100 mm

ta: 55°C max.

1812 6

H03VV-FH05VV-F

max.:

1 x 2,5

2 x 1,5

3–10 mm

NL

max. 105 VA

1–10 V

max. 2 m

+

654321–

TE-U0105 VA

NL

max. 105 VA

max. 2 m

+

654321–

TE-U0105 VA

control by electronic potentiometer

control by external1–10 V signal

A A B

A

A 25 mm / B 100 mm

ta: 55°C max.

1812 6

H03VV-FH05VV-F

max.:

1 x 2,5

2 x 1,5

3–10 mm

NL

max. 105 VA

1–10 V

max. 2 m

+

654321–

TE-U0105 VA

NL

max. 105 VA

max. 2 m

+

654321–

TE-U0105 VA

control by electronic potentiometer

control by external1–10 V signal

PHASED OUT