PRODUCT DATA Leviton Mfg. Co., Inc. Lighting & Energy Solutions 20497 SW Teton Avenue, Tualatin, OR 97062 1-800-736-6682 Tech Line: 1-800-959-6004 Fax: 503-404-5594 www.leviton.com/les © 2013 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice. O2C Dual Relay Multi-Technology Occupancy Sensors O2C Dual Relay Multi-Technology Occupancy Sensors DESCRIPTION The Leviton O2C Dual Relay Occupancy sensors combines line voltage occupancy sensors and photocells into a self-contained unit. The integrated design alleviates the need for separate power pack and occupancy sensor wiring making it a low-cost, efficient energy solution for new construction and retrofits. For true Daylight Harvesting applications, an integrated photocell provides consistent Daylight Design Levels by actively switching the connected load(s) ON and OFF in response to available natural light to maximize energy savings. Vacancy timers continually analyze and adjust to changing conditions using the latest microprocessor-based technology to optimize performance. Auto ON/ Auto OFF automatically turns lights ON and keeps them ON when occupancy is detected and automatically turns lights OFF when the space is vacant or unoccupied. Wire terminals allow for simple connection to a line-voltage circuit and are ideal for existing buildings with limited access to wiring and new construction. APPLICATIONS • Daylight Harvesting • CA Title 20/24 Compliant Occupancy Sensor • Auto-ON/Auto-OFF • Manual-ON/Auto-OFF • Dual Relay Modes Include: - Fan Control - Auto ON/Manual ON - Stairwell Control - Step Dimming - Alternating Daylighting Levels - Step Dimming - Load 1 Primary FEATURES • Sensors combine both PIR and U/S technol- ogy for unrivaled performance and reliability • Sensors use PIR technology to initially turn lights ON, and use U/S technology to keep the lights ON • Exclusive false-detection software assures lights are ON only when needed Auto temperature – adjusts tech sensitivity for optimal detection/operation Auto-Adapting: Time delay and sensitivity are continually adjusted to occupancy pattern of use • Vacancy Sensing Time Outs - Delayed OFF Timer - Exclusive Walk-through Feature • False Detection Timer: (M/T) PIR scans for movement and shuts lights off after 31 minutes without movement, preventing false triggers from HVAC systems - Time delay and saved settings are protected during power outages and will return to the last known state • Output short circuit protection • Industry-exclusive self-configuring local manual switch input: Momentary or maintained switches are supported • Presentation Mode allows user to turn lights OFF and keep them OFF while the room is occupied • Adjustable Time Delay: 30s, 5min, 10min, 20min, 30min • Test Mode for simplified commissioning • Manual Switch and Emergency Override are Class 1 and Class 2 circuits. Class 2 circuits provided for flexibility • Industry-exclusive “fail-safe” circuitry: In the event of product failure, Return-to-Closed feature causes the relay to default ON which eliminates life safety concerns Light Pipe

Upload: others

Post on 11-Mar-2020

12 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: O2C Dual Relay Multi-Technology Occupancy Sensors...O2C Dual Relay Multi-Technology Occupancy Sensors O2C Dual Relay Multi-Technology Occupancy Sensors DESCRIPTION The Leviton O2C

PRODUCT DATA

Leviton Mfg. Co., Inc. Lighting & Energy Solutions20497 SW Teton Avenue, Tualatin, OR 97062 1-800-736-6682 Tech Line: 1-800-959-6004 Fax: 503-404-5594 www.leviton.com/les© 2013 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.

O2

C D

ual R

elay

Mul

ti-T

echn

olog

y O

ccup

ancy

Sen

sors

O2C Dual Relay Multi-Technology Occupancy Sensors

DESCRIPTIONThe Leviton O2C Dual Relay Occupancy sensors combines line voltage occupancy sensors and photocells into a self-contained unit. The integrated design alleviates the need for separate power pack and occupancy sensor wiring making it a low-cost, efficient energy solution for new construction and retrofits. For true Daylight Harvesting applications, an integrated photocell provides consistent Daylight Design Levels by actively switching the connected load(s) ON and OFF in response to available natural light to maximize energy savings. Vacancy timers continually analyze and adjust to changing conditions using the latest microprocessor-based technology to optimize performance. Auto ON/Auto OFF automatically turns lights ON and keeps them ON when occupancy is detected and automatically turns lights OFF when the space is vacant or unoccupied. Wire terminals allow for simple connection to a line-voltage circuit and are ideal for existing buildings with limited access to wiring and new construction.

APPLICATIONS• Daylight Harvesting• CA Title 20/24 Compliant Occupancy Sensor• Auto-ON/Auto-OFF• Manual-ON/Auto-OFF• Dual Relay Modes Include: - Fan Control - Auto ON/Manual ON - Stairwell Control - Step Dimming - Alternating Daylighting Levels - Step Dimming - Load 1 Primary

FEATURES• Sensors combine both PIR and U/S technol-

ogy for unrivaled performance and reliability• Sensors use PIR technology to initially turn

lights ON, and use U/S technology to keep the lights ON

• Exclusive false-detection software assures lights are ON only when needed

• Auto temperature – adjusts tech sensitivity for optimal detection/operation

• Auto-Adapting: Time delay and sensitivity are continually adjusted to occupancy pattern of use

• Vacancy Sensing Time Outs - Delayed OFF Timer - Exclusive Walk-through Feature• False Detection Timer: (M/T) PIR scans for

movement and shuts lights off after 31 minutes without movement, preventing false triggers from HVAC systems

- Time delay and saved settings are protected during power outages and will return to the last known state

• Output short circuit protection• Industry-exclusive self-configuring local

manual switch input: Momentary or maintained switches are supported

• Presentation Mode allows user to turn lights OFF and keep them OFF while the room is occupied

• Adjustable Time Delay: 30s, 5min, 10min, 20min, 30min

• Test Mode for simplified commissioning• Manual Switch and Emergency Override are

Class 1 and Class 2 circuits. Class 2 circuits provided for flexibility

• Industry-exclusive “fail-safe” circuitry: In the event of product failure, Return-to-Closed feature causes the relay to default ON which eliminates life safety concerns

Light Pipe

Page 2: O2C Dual Relay Multi-Technology Occupancy Sensors...O2C Dual Relay Multi-Technology Occupancy Sensors O2C Dual Relay Multi-Technology Occupancy Sensors DESCRIPTION The Leviton O2C

PRODUCT DATAO

2C

Dua

l Rel

ay M

ulti

Tec

hnol

ogy

Occ

upan

cy S

enso

rsFEATURES• Industry-exclusive H.I.S. (High Inrush Stability)

technology designed to handle today’s high inrush electronic ballast loads and offer unmatched durability and service

• Robust and reliable mechanically held latching relay provides dependability and robust performance for all load types and provides energy savings over electronically held relays

• Field of View: Units from 500 to 2000 square feet available

• Lenses are easily replaceable and color-coded red (mid-range), black (extended range) and blue (high denisty) for contractors and end-users to easily iden-tify lenses from the ground

• Visual LED indicators for all states: - Red - Blinks when infrared is detecting motion and

during photocell manual calibration; solid during device malfunction

- Green - Blinks when U/S is detected; solid during auto calibration

- Yellow - Blinks during test mode; solid with emergency/BMS input

- Blue - Blinks when knob settings are changed and during photocell override

RATINGS AND TESTING• Zero-crossing circuitry for extended life of the relay• Tested to exceed 1 million switching cycles under

standard loads• Multiple compliance and regulatory UL testing -

consult factory for details • Passed rigorous NEMA 410 testing for electronic ballast

rating• BMS Input/Emergency Override: UL 924 listed for

Emergency and Egress lighting control

Photocell Features• Daylight Harvesting Applications:

• Auto-Calibration (Automatic Daylight Calibration): Photocell intelligently measures light levels to determine optimal daylight design levels for closed loop applications - Closed loop: Photocell detects total photometric light from daylight or electric sources in the space - Open loop: Photocell detects measurement of natural light only (sunlight from window or skylight)

• Adjustable daylight design levels: Normal (OFF), Manual (ON/OFF) and Auto Calibration

• Integrated photocell tested to less than 1 Fc accuracy

INSTALLATION• Easy installation into junction boxes with Leviton-

exclusive screw guides, coasters and terminal blocks

• Front cover snaps on and off for ease of installation

CLOSED LOOP

Noon

1.25x DDLZone ON

2.5x DDLZone OFF

Lights ONDDL

Dawn

01234567

Dusk

Closed Loop - Flat Light Pipe

PHOTOCELL PLACEMENT*

Window

Peak Sensitivity

68°

O2C04

Typical Dayligt Zone, about 10’

Light Fixture

9’

4’

Closed Loop Application - Flat Light Pipe

Peak Sensitivity

O2C04

Light Fixture

9’

45°

4’

Open Loop Application - Angled Light Pipe

OPEN LOOP

Noon

ON trigger pointLights turn ON

OFF trigger pointLights turn OFF

DDLLights ONNight time Dawn

01234567

Dusk

PHOTOCELL OPERATION

Note: Long side of angled light pipe must face toward natural light source (window)

Open Loop - Angled Light Pipe

*May require more than one occupancy sensor for total room coverage

Page 3: O2C Dual Relay Multi-Technology Occupancy Sensors...O2C Dual Relay Multi-Technology Occupancy Sensors O2C Dual Relay Multi-Technology Occupancy Sensors DESCRIPTION The Leviton O2C

Sid

ebar

Tit

le G

oes

Her

e

OD

C S

erie

s M

ulti

-Tec

hnol

ogy

Occ

upan

cy S

enso

rs

O2

C D

ual R

elay

Mul

ti T

echn

olog

y O

ccup

ancy

Sen

sors

PRODUCT DATA

Leviton Mfg. Co., Inc. Lighting & Energy Solutions20497 SW Teton Avenue, Tualatin, OR 97062 1-800-736-6682 Tech Line: 1-800-959-6004 Fax: 503-404-5594 www.leviton.com/les© 2013 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.

DIMENSIONS

INSTALLATION

Sensors conveniently mount to a standard 4” x 4” square or octagon electrical box per NEC standards.

4”x4” Cosmetic Adapter

Angled light pipe

Screw Guides

Flat light pipe

FIELD OF VIEWS

TOP VIEW20

11.5

8.5

0

8.5

Major Motion, IR

Minor Motion, Ultrasonic

Major Motion, Ultrasonic

11.5

20

8

00 3 5.6 9 11 15

1720

23

SIDE VIEW

TOP VIEW

Major Motion, IR

Minor Motion, Ultrasonic

Major Motion, Ultrasonic

20

11.5

16

0

8.5

11.5

20

8

00 33 5.55.5 99 1111 1515

22.522.52020

3232

SIDE VIEW

15

15

10

10

20

0 5 10 15 20 2530 25 20 15 10 5 30

5

5

0

TOP VIEW

SIDE VIEW

O2C05-MDW Multi-Range Lens (Included with all PIR and Multi-Tech Models)

O2C20-MDWO2C10-MDW

TOP VIEW

Major Motion, IR

Minor Motion, Ultrasonic

Major Motion, Ultrasonic

20

11.5

8.5

0

8.5

11.5

20

8

00 33 5.65.6 99 1111 1515

17172020

2323

SIDE VIEW

4.80”(121.92mm)

1.13”(29.91mm)

0.94”

(24.06mm)

2.39”

(60.71mm)

1.16”(29.60mm)

Page 4: O2C Dual Relay Multi-Technology Occupancy Sensors...O2C Dual Relay Multi-Technology Occupancy Sensors O2C Dual Relay Multi-Technology Occupancy Sensors DESCRIPTION The Leviton O2C

PRODUCT DATAS

ideb

ar T

itle

Goe

s H

ere

O2

C D

ual R

elay

Mul

ti T

echn

olog

y O

ccup

ancy

Sen

sors

ORDERING INFORMATION

ELECTRICALInput Voltage 120V, 50/60Hz 230V, 50Hz 277V, 50/60Hz

Load Rating

8A, Electronic Ballast, 800W, Tungsten, 800VA Ballast, 1/4 HP Motor

6A/6AX, Electronic Ballast, Magnetic Ballast, Tungsten,1/3 HP Motor

5A, Electronic Ballast, 1200VA Ballast, 1/3 HP Motor

Current Consumption 60-30ma

ENVIRONMENTAL

Operating Temperature 32° to 104° F (0° to 40° C)

Storage Temperature -15° to 160° F (-26° to 71° C)

Relative Humidity 0% to 90% non-condensing

OTHERListings CA Title 20/24 Compliant, UL 773A (Occupancy Standard),

UL 924 (Emergency Equipment), cUL Listed, CE Compliant, NOM Certified, RoHS Compliant, NY LLC48 Compliant

Warranty 5-Year Limited Warranty

SPECIFICATIONS

Leviton Manufacturing Co., Inc. Global Headquarters201 N. Service Rd. Melville, NY 11747-3138 • Tech Line: 1-800-824-3005 • Fax: 1-800-832-9538

Leviton Manufacturing Co., Inc. Lighting & Energy Solutions20497 SW Teton Avenue, Tualatin, OR 97062 • Tele: 1-800-736-6682 • FAX: 503-404-5594 • Tech Line (6:00AM-4:00PM P.S.T. Mon-Fri): 1-800-959-6004

Leviton Manufacturing of Canada, Ltd.165 Hymus Boulevard, Pointe Claire, Quebec H9R 1E9 • Telephone: 1-800-469-7890 • FAX: 1-800-563-1853

Leviton S. de R.L. de C.V.Lago Tana 43, Mexico DF, Mexico CP 11290 • Tel. (+52) 55-5082-1040 • FAX: (+52) 5386-1797 • www.leviton.com.mx

Visit our Website at: www.leviton.com/les© 2013 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice. G-9149/K13-aa

CAT. NO. DESCRIPTION

O2C05-MDWMulti-Technology Ceiling Mount Line Voltage Dual Relay Occupancy Sensor w/Integrated Photocell, 500SF, 120-277V, Extended Range Lens installed

O2C10-MDWMulti-Technology Ceiling Mount Line Voltage Dual Relay Occupancy Sensor w/Integrated Photocell, 1000SF, 120-277V, Extended Range Lens installed, Mid-Range included

O2C20-MDWMulti-Technology Ceiling Line Voltage Dual Relay Mount Occupancy Sensor w/Integrated Photocell, 2000SF, 120-277V, Extended Range Lens installed, Mid-Range included