nolta us catalog complete[1]
TRANSCRIPT
NOLTA Inc.27 Olive St.Northampton, MA 01060USAPhone (212) 231 8344Fax (212) 231 [email protected]
Motorstarter Solutions Water Technology
CatalogVer
sio
n:
Feb
ruar
y20
10
Motorstarter Solutions
3
The Products
Overview Motorstarter Solutions 4 – 5
Rotary-toggle 6 – 7
Push-button 8 – 9
Powerstarter 10 – 11
Power-Reverser 12 – 13
Overview Water Technology 14 – 15
Level controller MS 1 16 – 17
Level controller MS 1 C 18 – 19
Level controller M 2 20 – 21
Level controller N 1 22 – 23
Accessories 24 – 25
Technical Data 26 – 27
The Company 28 – 29
Your Contacts 30
5
OverviewMotorstarter Solutions Motorstarter Solutions
Overview
Nominal motors currents of three-phase-motors (standard values for cage rotors)
The standard values are for nominal internal and surface cooled three-phase-motors with 1500rpm.
NOLTA motor starters offer optimummotor protection through:
Thermal over-stressing protection1. ■ No over-stressing of engine and cables
Magnetic high-speed circuit breaker2. ■ Quick and save disconnection in case of short circuit
Integration in plug3. ■ Saves costs since no extra space is required
■ Higher flexibility
Rotary field check, phase inverter and 4. equipment-on indicator
■ Protection from incorrect engine torque direction
Automatic or manual control5. ■ Connections for floats or control conduit
■ Automatic restart
High resistance to short-circuits 6. (only at thermal-electromagnetic release)
■ No back-up fuse necessary(see datasheet: To Icc = 50 kA)
4
4pol.3P+E
5pol.3P+E+N
4pol. 5pol.4h 4h
4pol. 5pol.9h 9h
4pol. 5pol.6h 6h
4pol. 5pol.7h 7h
4pol. 5pol.10h 10h
4pol. 5pol.2h 2h
NOLTA – motor protection starters for one and three phaseelectrical motors – cost efficient due to high flexibility inapplication and configuration.
■ Thermo-magnetic motor protection
■ On /off switch
■ Robust polycarbonate housing
■ Combination with IEC or CEE plug connection
Power 230 V 400 V 500 V Power(HP) A A A (kw)
0.33 1.3 0.8 0.6 0.25
0.5 2.1 1.2 0.9 0.37
0.75 2.7 1.6 1.2 0.55
1.1 3.6 2.1 1.55 0.80
1.5 4.7 2.7 2.0 1.1
2.0 6.0 3.4 2.7 1.5
3.0 8.5 4.9 3.7 2.2
4.0 11.0 6.4 4.9 3.0
5.5 15.0 8.6 6.5 4.0
7.5 20.0 11.5 8.7 5.5
10.0 26.0 15.0 11.5 7.4
15.0 39.0 22.5 17.0 11.0
O r d e r e m a i l : s a l e s @ n o l t a i n c . c o m O r d e r p h o n e : + 1 ( 2 1 2 ) 2 3 1 8 3 4 4
O r d e r f a x : + 1 ( 2 1 2 ) 2 3 1 8 1 2 1 7
Rotary-toggle Rotary-toggle
6
All NOLTA rotary toggles are equipped with a rotary toggle switch withthermal-electromagnetic release.The motor starter switch can be used as on /off switch. Optionally the NOLTA rotary toggle is available with a phase sequence indicator.
Available versions:
Voltage Features Order-noFrequency
60 3942..
Phase sequence indicator 60 3945..
Phase sequence indicator 60 3946..
Phase sequence indicator 60 3948..
Other versions available upon request
Ranges of adjustment:The NOLTA rotary toggle for tough building sites and industrial employment, e.g.:
■ Pumps
■ Buzz saws
■ Industrial motors
Adjustment rangemax. Order-No.
back up fuse addition
0.10 – 0.16 A ..21
0.16 – 0.25 A ..22
0.25 – 0.40 A ..23
0.40 – 0.63 A ..24
0.63 – 1.00 A ..25
1.00 – 1.60 A ..26
1.60 – 2.50 A ..27
2.50 – 4.00 A ..28
4.00 – 6.30 A ..29
6.30 – 9.00 A 40 A ..30
9.00 – 12.50 A 50 A ..31
12.50 – 16.00 A 63 A ..32
16.00 – 20.00 A 80 A ..33 *
20.00 – 25.00 A 100 A ..34 *
*) only available with CEE 32 A
Short-circuit-
protection:
no fusing is
necessary
to Icc = 50 kA
Tripping characteristic:
Technical data:Housing material: PolycarbonateProtection class: IP 44Length: 10.4 in (265 mm)Width: 3.3 in (87 mm)Height: 3.3 in (85 mm)Weight: approx. 1.6 lb (740 g)
O r d e r p h o n e : + 1 ( 2 1 2 ) 2 3 1 8 3 4 4
How to specify your order:60 394830
60 .. Main group
.. 3948 .. Type description
.. 30 Adjustment range
NOLTA motorstarter, 500 V, 50 - 60 Hz, Adjustment range 6.3 – 9.0 A, with phase sequence indicator
Technical data subject to change
50-600 V, 50-500 Hz
110-125 V, 50-60 Hz
200-250 V, 50-60 Hz
440-500 V, 50-60 Hz
For use as on /off switch for your machines
Magnetical quick release (short-circuit-protection)
Thermal overload protection (adjustable)
Phase sequence indicator (optional)
O r d e r e m a i l : s a l e s @ n o l t a i n c . c o m 9
Push-button Push-button
8
All NOLTA Push-Buttons are equipped with a thermo magnetic release push button starter, that can be used as on /off switch. The compact yet spacious design allows for integration of additional modules such as under voltage and shunt trip coils. Optionally the NOLTA Push Button is available with a phase sequence indicator.
The NOLTA push-button offers optimal protection for all electric motors, e.g.:
■ Pumps
■ Compressors
■ Blowers
To use as on/off switch for your machines
Magnetical quick release (short-circuit-protection)
Thermal overload protection (adjustable)
Under voltage release (optional)
Ranges of adjustment:
Adjustment rangemax. Order-No.
back up fuse addition
0.10 – 0.16 A ..21
0.16 – 0.25 A ..22
0.25 – 0.40 A ..23
0.40 – 0.63 A ..24
0.63 – 1.00 A ..25
1.00 – 1.60 A ..26
1.60 – 2.50 A ..27
2.50 – 4.00 A ..28
4.00 – 6.30 A ..29
6.00 – 10.00 A ..30
9.00 – 14.00 A 80 A ..31
13.00 – 18.00 A 80 A ..32
17.00 – 23.00 A 80 A ..33
20.00 – 25.00 A 80 A ..34
24.00 – 32.00 A 80 A ..35
Short-circuit-
protection:
no fusing is
necessary
to Icc=50 kA
Tripping characteristic:
Technical data:Housing material: PolycarbonateProtection class: IP 44Length: 11 in (280 mm)Width: 4.3 in (110 mm)Height: 3.7 in (95 mm)Weight: approx. 2 lb (910 g)
O r d e r p h o n e : + 1 ( 2 1 2 ) 2 3 1 8 3 4 4
Phase sequence indicator (optional) Available versions:
Voltage Features Order-no.Frequency
60 6942..
Phase sequence indicator 60 6945..
Phase sequence indicator 60 6946..
Phase sequence indicator 60 6948..
Other versions available upon request
How to specify your order:60 694830
60 .. Main group
.. 6948 .. Type description
.. 30 Adjustment range
NOLTA motorstarter, 500 V, 50 - 60 Hz, Adjustment range 6.0 – 10.0 A, with phase sequence indicator
Technical data subject to change
50-600 V, 50-300 Hz
110-125 V, 50-60 Hz
200-250 V, 50-60 Hz
440-500 V, 50-60 Hz
11
Powerstarter Powerstarter
10
All NOLTA Powerstarter switches are equipped with a rotary toggle switch to start and stop the connected motor. Optionally NOLTA powerstarter switches are available with a phase sequence indicator.
The NOLTA powerstarter switch for safe switching of all electric motors, e.g.:
■ Agitors
■ Reversing motors
■ Conveyors
Power andpower reversing switch
Phase sequence indicator (optional) Available versions:
With power switch max. 32 A
Other versions available upon request
Technical data:Housing material: PolycarbonateProtection class: IP 44Length: 10 in (255 mm)Width: 3.3 in (84 mm)Height: 2.8 in (70 mm)Weight: approx. 1 lb (460 g)
Technical data subject to change
O r d e r f a x : + 1 ( 2 1 2 ) 2 3 1 8 1 2 1 O r d e r p h o n e : + 1 ( 2 1 2 ) 2 3 1 8 3 4 4
Voltage Features Order-no.Frequency
63 1700..
Phase sequence indicator 63 1745..
Phase sequence indicator 63 1746..
Phase sequence indicator 63 1748..
50-500 V, 50-60 Hz
110-125 V, 50-60 Hz
200-250 V, 50-60 Hz
440-500 V, 50-60 Hz
13
Power-Reverser Power-Reverser
12
All NOLTA power-reverser switches are equipped with a rotary-toggle switch,which is used alternatively as operating or power reversing switch.Optionally NOLTA power-reversing switches are available with a phase sequence indicator.
The NOLTA Power-Reverser for safe switching of all electric motors, e.g.:
■ Agitors
■ Reversing motors
■ Conveyors
Power andpower reversing switch
Phase sequence indicator (optional) Available versions:
Other versions available upon request
With power reversing switch max. 20 A
Technical data:Housing material: PolycarbonateProtection class: IP 44Length: 10 in (255 mm)Width: 3.3 in (84 mm)Height: 2.8 in (70 mm)Weight: approx. 1 lb (455 g)
Technical data subject to change
O r d e r e m a i l : s a l e s @ n o l t a i n c . c o m O r d e r p h o n e : + 1 ( 2 1 2 ) 2 3 1 8 3 4 4
Voltage Features Order-no.Frequency
63 1800..
Phase sequence indicator 63 1845..
Phase sequence indicator 63 1846..
Phase sequence indicator 63 1848..
50-500 V, 50-60 Hz
110-125 V, 50-60 Hz
200-250 V, 50-60 Hz
440-500 V, 50-60 Hz
15
OverviewWater Technology Water Technology
Overview
NIVA is the water technology brand of NOLTA.NIVA level controllers are the ideal solution foryour applications through…
High material resistance1. ■ Due to special materials, even the standard versions meet the requirements of 90% of all applications.
Internal weight2. ■ Cost efficient since no additional cable weight is necessary. The level controller remains in place on its own weight.
Special application variants3. ■ Solutions for special applications such as EX zones, high temperatures, solvents, and potable water.
Easy installation4. ■ The same type of controller can be wired to work in filling or emptying applications.
Form follows function5. ■ High reliability even in small diameters. The drop shaped design keeps solid matter from getting stuck on the edges, ensuring proper function of the controller.
Reliable functionality6. ■ Very long lasting almost maintenance-free functionality due to robust materials and a special cast resin encapsulation technique.
14 O r d e r f a x : + 1 ( 2 1 2 ) 2 3 1 8 1 2 1 O r d e r p h o n e : + 1 ( 2 1 2 ) 2 3 1 8 3 4 4
17
Level Controller MS1 Level Controller MS1
16
The NIVA level controller MS 1 is engineered especially for use in sewage works and pumping stations inliquids heavily charged with solid matter such as raw sewage etc. Thanks to the good chemical and ther-mal properties our level controllers are resistant to lees, uric acid, fecal sewage water, oils, petrol, dieseloil, emulsions, alcohol, fruit acids, and even many chemicals. For use at temperatures up to 176 °F (80 °C).The MS 1 has been submitted for UL certification. Optionally the level controller MS 1 is available withEX-certificate in accordance with EC directive 94 /9 (ATEX 95). Please contact us for further information.
The NIVA level controller MS1 is the ideal solution to control liquid levels with limited switching space, e. g. in:
■ Pump stations
■ Wells
■ Pump chambers
Available versions:
Application:
Type Cable Length (ft) Order-no.
W TPR / PVC 3 x 0.75 16 40 000105
W TPR / PVC 3 x 0.75 30 40 000110
W TPR / PVC 3 x 0.75 65 40 000120
W TPR / PVC 3 x 0.75 98 40 000130
Other cable types and lengths are available upon request
Electronic connectionConnection of Wire
level controllers grey black brown
For emptying a tank insulate X X
For fillinga tank X insulate X
Alarm highlevel insulate X X
Alarm lowlevel X insulate X
Technical data subject to change
Technical data:Specific weight: 0.95 –1.05 or according to specificationMax. temperature: 176 ° F (80 °C)Breaking capacity: 1 mA / 4 V - 5 A / 250 V *Switch point: 10 °Protective system: IP 68 / 2 barEquipment group: IICable cross section: 3 x 0.75 mm2
Height / diameter: 7 in / 3.9 in (180 / 100 mm)Housing quality: Polypropylene (PP)Housing Colour: OrangeCable quality: TPR / PVCCable colour: Orange
* Micro-switch with gold-plated contacts especially for low currents in electronic circuits
For use in municipal, industrial, commercial and domestic applications.
O r d e r e m a i l : s a l e s @ n o l t a i n c . c o m O r d e r p h o n e : + 1 ( 2 1 2 ) 2 3 1 8 3 4 4
W = Changeover (SPDT)
19
Level Controller MS1 C Level Controller MS1 C
18
The NIVA level controller MS 1 C was designed for an extremely high resistance to chemical liquids and for use at high temperatures up to 212 ° F (100 ° C).
The NIVA level controller MS1 C is the ideal solution to control liquids with limited switchingspace. For example in:
■ Chemical plants
■ Electro plating shops
■ Purifying Plants
Available versions:
Application:
Type Cable Length (ft) Order-no.
W Teflon / FEP 4 x 0.5 16 40 000705
W Teflon / FEP 4 x 0.5 30 40 000710
W Teflon / FEP 4 x 0.5 65 40 000720
Other cable types and lengths are available upon request
Technical data:Specific weight: 0.95 –1.05 or according to specificationMax. temperature: 212 ° F (100 °C)Breaking capacity: 1 mA / 4 V - 5 A / 250 V *Switch point: 10 °Protective system: IP 68 / 2 barProtection class: IICable cross section: 4 x 0.5 mm2
Height / diameter: 7 in / 3.9 in (180 / 100 mm)Housing quality: Polypropylene (PP)Housing Colour: GreyCable quality: Teflon (FEP)Cable colour: BlackCable seal: Viton
* Micro-switch with gold-plated contacts especially for low currents in electronic circuits
For use in chemically loaded liquids at temperatures up to 212 °F (100 °C).
O r d e r f a x : + 1 ( 2 1 2 ) 2 3 1 8 1 2 1 O r d e r p h o n e : + 1 ( 2 1 2 ) 2 3 1 8 3 4 4
Electronic connection
For emptying a tank insulate X X X
For fillinga tank X insulate X X
Alarm highlevel insulate X X X
Alarm lowlevel X insulate X X
Technical data subject to change
�Connection of Wire
level controllers grey black brown
Potential equalization wire �
W = Changeover (SPDT)
21
Level Controller M 2 Level Controller M 2
20
Due to its smaller volume and its lesser buoyancy force, the „small“ level controller M 2 is only suitable for use in media without large amounts of solid matter and especiallysuitable for use in small tanks with limited space
The NIVA level controller M2 is the ideal solution to control liquids with very limited switching space. For example in:
■ Constricted diameters
■ Narrow hoppers
■ Small tanks
With premounted cable weight (300 g):
Application:
Type Cable Length (ft) Order-no.
W TPR / PVC 3 x 0.5 16 40 000605
W TPR / PVC 3 x 0.5 30 40 000610
W TPR / PVC 3 x 0.5 65 40 000620
Other cable types and lengths are available upon request
Available versions:
Type Cable Length (ft) Order-no.
W TPR / PVC 3 x 0.5 16 40 000505
W TPR / PVC 3 x 0.5 30 40 000510
W TPR / PVC 3 x 0.5 65 40 000520
Other cable types and lengths are available upon request
Electronic connectionConnection of Wire
level controllers grey black brown
For emptying a tank insulate X X
For fillinga tank X insulate X
Alarm highlevel insulate X X
Alarm lowlevel X insulate X
Technical data subject to change
Technical data:Specific Weight: 0.95 –1.05Max. temperaturee: 176 ° F (80 °C)Breaking capacity: 1 mA / 4 V - 2 A / 250 V *Switch point: 10 °Protective system: IP 68 / 2 barProtection class: IICable cross section: 3 x 0.5 mm2
Height / diameter: 3.5 in / 2.4 in (90 / 60 mm)Housing quality: Polypropylene (PP)Housing Colour: OrangeCable quality: TPR / PVCCable colour: Orange
* Micro-switch with gold-plated contacts especially for low currents in electronic circuits
Liquids without solids. Small diameters. For cable weights to stabilize and adjust the switching point see page 24.
O r d e r e m a i l : s a l e s @ n o l t a i n c . c o m O r d e r p h o n e : + 1 ( 2 1 2 ) 2 3 1 8 3 4 4
Also available with premounted cable weight (see page 24)
W = Changeover (SPDT)
2322
Level Controller N 1 Level Controller N 1
The NIVA level controller N1 can be used everywhere where liquid levels must be supervised.The NIVA N1 is simple to install and maintenance-free. Thus fast economical and reliable solu-tions for your application can be realized. Different to the MS Control switches, the N1 is apump switch which can be used for direct control of pumps.
The NIVA level controller N 1is the ideal solution to control the level of most diverseliquids, for example in:
■ Construction site dewatering
■ Industrial filling plants
■ Pit draining
Available versions:
Application:
Type Cable Length (ft) Order-no.
W H05RR-F 4G0.75 16 41 001405
W H05RR-F 4G0.75 30 41 001410
W H05RR-F 4G0.75 65 41 001420
Other cable types and lengths are available upon request
Technical data:Specific Weight: 0.95 –1.05Max. temperaturee: 140 ° F (60 °C)Breaking capacity: 10 (8) A / 250 V - 21 (4) A / 250 VSwitch point: 45 °Protective system: IP 68 / 2 barProtection class: IICable cross section: 4G0.75 mm2
Length / Width / Hight: 5.2 / 3.2 / 1.7 in (132 / 81 / 43 mm)Housing quality: Polypropylene (PP)Housing Colour: Yellow / BlackCable quality: H05RR-FCable colour: Black
For direct pump control in large diameter water basins and dewatering applications.
O r d e r f a x : + 1 ( 2 1 2 ) 2 3 1 8 1 2 1 O r d e r p h o n e : + 1 ( 2 1 2 ) 2 3 1 8 3 4 4
Electronic connection
For emptying a tank insulate insulate X X
For fillinga tank X X X X
Alarm highlevel insulate insulate X X
Alarm lowlevel X X X X
Technical data subject to change
�Connection of Wire
level controllers blue black brown
W = Changeover (SPDT)
Potential equalization wire �
2524
Accessories Accessories
Cable support bracket Ord.-No. 40 02
The stainless steel support bracket is mounted on the wall. With theincluded M16 cable glands, one ortwo level controllers can be suspen-ded freely at exactly the requiredheight. Comes with screws andanchors (M6).
Technical data:Material: stainless steelSize: approx. 11 x 41/3 x 1.2 in
(280 x 110 x 30 mm)Cable gland: M16 PolyamideClamping range: 0.18 - 0.4 in (4.5 - 10 mm)Anchor: M6 x 67 A4
Cable weight Ord.-No. 40 03
The NIVA cable weight 40 03 weighs approximately 1.5 lb (700 g)and can be used on all level controllers. The weight can be retrofitted onalready installed controllers.
Cable weight Ord.-No. 40 00 and 40 01
The NIVA cable weight 4000 weighsapproximately 0.7 lb (300 g) and can be used with NIVA level controller M2.
Cable weight 4001 weighs approxi-mately 1.5 lb (700 g) and can be usedwith NIVA level controllers MS1, N1and KR1.
Both weights must be fixed to thecable before installing the level controllers.
Technical data:Weight: 1.5 lb (700 g)Material: cast iron, plastic laminatedCable fixation: 3 cut-outsSize (L/W/H): 7,5 x 1.2 x 1 in
(190 x 31 x 27 mm)
Technical data:Weight: 40 00 = 0.7 lb (300 g)
40 01 = 1.5 lb (700 g)Housing quality: Polypropylene (PP)Cable gland: M16 PolyamideClamping range: 0.18 - 0.4 in (4.5 - 10 mm)Size: Ø 2.36 in x 4.33 in
(Ø 60 mm x 110 mm)
O r d e r e m a i l : s a l e s @ n o l t a i n c . c o m O r d e r p h o n e : + 1 ( 2 1 2 ) 2 3 1 8 3 4 4
2726
Technical Data Technical Data
O r d e r f a x : + 1 ( 2 1 2 ) 2 3 1 8 1 2 1 O r d e r p h o n e : + 1 ( 2 1 2 ) 2 3 1 8 3 4 4
When installing the level controllers make sure that they are suspended freely and vertically, that they do not rest on the base, that they can float withoutinterference from the shaft walls, pipes, fittings etc. andthat they are not exposed directly to currents.
For simple mounting we can supply cable support brackets. The stainless steel support bracket is mountedon the wall. With the included M16 cable glands, one or two level controllers can be suspended freely atexactly the required height (see page 24).
The level controllers are resistant to the following liquids.
max. working temperature 80 °C (176 °F)
Meets the requirements in 90% of all applications. max. working temperature 100 °C (212 °F)
These lists were compiled to the best of one’s knowledge and information from our material suppliers. As there is no plastic,which is resistant against all media and temperatures, mix ratio, surface tension, pressure ratio etc. are also important; in criticalapplications practical tests should be done before usage.
Level controller MS1 / MS1 electronicEX / M 2 / KR1 / KR1 electronic EX
sewage water faecal water liquid manure domestic sewage sewage of washing machines,bathes and showerssuds
emulsion with parts of diesel oils / fets / oil / acids etc.
max. working temperature 70 °C (158 °F)
Level controller MS1 ACS
potable water / food applications
rain water ground water sea water / river watermineral water chlorine water saltwater brine
vegetable oils fruit acids alcohol
For extreme applications MS1C / MS1 electronic EX with teflon cable
accumulator acid fuel bore oils ATE - brake fluiddiesel oils transfomer oil petroleum fatty acid non-freeze liquid gear oils fuel oils hydraulic fluid turbine oil
degreaser base solvent - containing fluidslactic acid, watery mineral oils engine oils petrol lube oils sulphuric acid - containing fluidshydrochloric acid - containing fluids ethyl alcohol galvanic bath
Technical explanations to Watertechnics
Function
Resistance list
The high level controllerstarts the pump …
… which regulates the level …
… to a predeterminedlow level.
The low level controllerstops the pump.
Through inflow, the level rises again …
… ... until the determined high level is reached …
… and the pump processbegins anew.
Installation
The level controllers are usually connected to a low voltage control circuit through a control panel.They may not operate directly on an electrical supply line, e.g. not directly on a pump motor, except type N 1.
Electrical Connection
If correctly installed and mounted, the level controllersfunction is practically maintenance-free. Depending on the medium's pollution level, the installation must be checked from time to time for dirt deposits and cleaned if necessary.
Maintenance
Potential eualization wire only in level controller MS 1 electronic EX, MS 1 C, N 1 and KR 1 electronic Ex.
�
For emptying a tank insulate insulate X X
For fillinga tank X X X X
Alarm highlevel insulate insulate X X
Alarm lowlevel X X X X
�Connection of Wire
level controllers grey black brown
30 O r d e r f a x : + 1 ( 2 1 2 ) 2 3 1 8 1 2 1 O r d e r p h o n e : + 4 9 - 6 4 2 1 - 9 8 5 9 0
Your Contacts
Beate Jäger-Becker Head of Material Management, Production and Customer ServiceFon +49 6421/985913 Fax +49 6421/985928 [email protected]
Felix BonnHead of Sales and MarketingFon +1(212)231 8344 Fax +1(212)231 8121 [email protected]
Wolfgang SeipEngineering, Quality and EnvironmentalManagementFon +49 6421/985926 Fax +49 6421/985928 [email protected]
Stefan Wege Research and DevelopmentFon +49 6421/985919 Fax +49 6421/985928 [email protected]
Water Technology
Water and Water technology are among themost mentioned megatrends of the future. SinceNOLTA has been active in this field for manyyears, and has made a name for itself in theindustry, it has been decided to further streng-then our position in the segment of “watertechnology” and concentrate more on this futu-re trend. The acquisition of our long time salespartner NIVA was the strategic consequence.
NIVA GmbH is a manufacturer with highest quali-ty standards. For many years they have producedlevel controllers for the industry's leading pumpmanufacturers. The merger of both companiesconcentrates the know-how of two market lead-ers under one roof. Now NOLTA can supply itscustomers with a complete range of products inthe field of pump monitoring and control all fromone source.
The best of both worlds: NOLTA and NIVA
29
The Company The Company
Customer satisfaction is our company’s priority We achieve this through the quality ofour products and services, with the benchmarkset by our customers.
The quality of our products and services isdependent on the individual effort of eachemployee along with continuous programs ofsupervision and quality control.
Under these prime conditions the requirementsand specification set forth by our customers are fulfilled.
Our commitment to improve our products andservices is done on a daily basis. Managementplays an integral part in ensuring the high
standards demanded by our customer are met at all levels at Nolta GmbH.
Our CEO Dr.-Ing. Jochen Knake
The quality policy of Nolta GmbH
We understand quality not only in regards to ourproduct but also in our service to our customers.Product quality is a matter of course and ourhighest priority. What distinguishes us fromothers, is our exemplinary service which hasmade Nolta GmbH a reliable and trusted partnerin motor protection and water technology forover 50 years. We see ourselves not only as
manufacturer and supplier of high quality productsbut also as service provider for our customers. This includes uncomplicated communication chan-nels and qualified consultation as well as targetoriented training opportunities through the NoltaAcademy. We provide our customers with top endproducts and 50 years of experience in motorprotection and water technology.
The service philosophy of Nolta GmbH
At Nolta, we see the natural wealth of our environment as the foundation of our economicactions. Our actions are guided by our concernfor the environment and our efforts to protect itfrom harmful influences. For this reason, we manufacture our productsusing energy saving and environment friendlytechniques. And when our products come to the end of their useful lives,
we dispose of them in environmentally friendlyways. At every level of management, we integrate theconcern for the environment in our decisionmaking process. Protecting the environmentrequires responsible actions by all employees.Furthermore, managers have the extra responsi-bility to ensure our environmental policies are followed and to lead by example.
Nolta GmbH and the environmental
The main components in the quality of our product are the protection of our environmentand the safety of our employees.
The basis for fulfilling these components is anintegrated management system for qualitymanagement, environmental protection andoccupational safety.
We feel that it is our obligation to reach the best quality in our products while actingecologically responsible.
At Nolta we undertake regular checks as towhether the actions of our company are in linewith this policy, fulfill all legal requirements andstrive for constant ecological improvement.
We want to ensure the technological andorganizational implementation as well as thesuccess of our environmental policy through ourmanagement system.
The integrated management system of Nolta GmbH
Complex machines and pump solutions requirespecialized knowledge. As your partner, Nolta makes information aboutour products available to both manufacturers andend users. The Nolta Academy hosts regular seminars training courses on operating, protecting, controlling, maintaining, and monitoring machines and pumps.
Nolta Acadamy
O r d e r e m a i l : s a l e s @ n o l t a i n c . c o m O r d e r p h o n e : + 1 ( 2 1 2 ) 2 3 1 8 3 4 428