multilin™ epm 6010 - ge grid solutions...epm 6010 building automation power meter...
TRANSCRIPT
g Energy
• RapidintegrationintoBACnetmanagementsystems
• Highaccuracymultifunctionpowermeter,0.2%classrevenuecertifiableenergyanddemandmetering
• Ultracompactandeasytoinstall,fitsbothANSIandDINcutouts
• EnerVista™softwaremakesmetereddataandpowerqualitystatuseasilyaccessible
• Userprogrammablefordifferentsystemvoltagesandcurrentmeasurements
• StandardModbus™TCPcommunications
• Easytoread,large3line.56”brightLEDdisplayforbettervisibilityandlongerlife
• LEEDprojects
• Smartbuildings
• Commercialenergymanagement
• HVACefficiencymonitoring
• Buildingmanagementsystems
Communications
• BACnet/IP100BaseTEthernetprotocol
• 40pre-definedBACnetobjectsfacilitaterapidintegration
• Embeddedweb-server,allowsBACnet/IPinterfacetoberemotelyconfiguredandBACnetobjectscanberemotelyviewedovertheinternetwithawebbrowser
• StandardModbusTCPcommunicationscanbeusedtopolltheEPM6010whileBACnet/IPinterfaceisbeingused
Measuring and Metering
• Highaccuracymultifunctionpowermeter,0.2%classrevenuecertifiableenergyanddemandmetering
• Samplesat400+timespercycleandhas24bitA/Dconversiontomeasureaccuratelyandreliably
• MeetsANSIC12.20(0.2%)andIEC687(0.2%)accuracyclasses
• Totalharmonicdistortion(%THD)
• Loadpercentagegraphicalbarforinstantloadvisualization
• TrueRMSmultifunctionmeasurementsincludingvoltage,current,power,frequencyandenergy
FEATURES
APPLICATIONS
KEY BENEFITS
EPM 6010BUILDING AUTOMATION POWER METER
BACnet®/IPCommunicationsandEnergyMeasurement
Multilin™
2
EPM 6010Building Automation Power Meter
GEDigitalEnergy.com
CommunicationsPortsThe Multilin EPM 6010 provides twoindependent communication ports withadvancedfeatures:
• IrDA port–AuniqueopticalIrDAportallowstheunittobesetupandprogrammedusingaremotelaptopwithoutneedingacommunicationcable.SimplypointatthemeterwithanIrDA-equippedPCcomputertoconfigureit.
• Ethernet Port–Thisportprovidesconnectivityviaa10/100BaseTRJ45connection.ModbusTCPandBACnetprotocolsaresupported.
BACnet/IPWebInterfaceThe Multilin EPM 6010 comes standardwithaweb interface.Use theBACnet/IPinterfacetoremotelysetuptheBACnet/IPconfigurationandtrackenergyusewithanystandardwebbrowser.
EnerVistaSoftware
EnerVista Software
EnerVista Launchpad is a powerfulsoftware package that provides users aplatform to access all of the setup and
OverviewThe Multilin EPM 6010 is an industryleading revenue grade power meterwith native BACnet/IP communications.This meter is designed to integrateseamlesslyintoexistingandnewbuildingmanagementsystemsusingthepopularBACnetprotocol.Themeterallowsuserstogatherdataonvoltage,current,powerandenergyusagethroughoutafacility.
Designed to be the perfect device forenvironmental initiatives, LEED certifiedprojects and smart energy projects, theEPM 6010 provides superior metrology,and revenue testable 0.2% energyaccuracy.ThemeterisincompliancewithANSI and IEC accuracy standards, hasadvanced DSP technology, samples athighrates,andhas24bitA/Dconversiontomeasureandanalyzepoweraccuratelyandreliably.
BACnetCommunicationsThe Multilin EPM 6010 with BACnet/IPsupports building energy managementstrategies, LEED certification and otherGreen Building initiatives. By allowingusers to track energy use and powerquality, the meters gives users theinformation they need to accuratelyidentify cost-saving measures andrespondtopowerqualityproblemswhentheyarise.
MeasuredValuesEPM6010measuresthefollowingvalues:
MEASURED VALUES
REAL-TIME AVG MAX MIN
Voltage L-N • • •Voltage L-L • • •Current Per Phase • • • •Watts • • • •VAr • • • •VA • • • •PF • • • •+Watt-hr •-Watt hr •Watt-hr net •+VAr-hr •-VAr-hr •VAr-hr net •VA-hr •Frequency • • •Voltage Angles •Current Angles •%THD • • •% of Load Bar •
BACnet home web page
BACnet/IP interface statistics
View BACnet objects and their status
3
EPM 6010Building Automation Power Meter
GEDigitalEnergy.com
Direct PC Interface
HTTP Web Server
BACnet/IP
Modbus TCPWireless Communication
support tools needed for configuringand maintaining GE Multilin Products.Launchpad allows configuration ofdevices in real-time by communicatingusingRS232,RS485,Ethernet,ormodemconnections.
UsingLaunchpadasthesingle interfacetothesetupandanalysissoftwaremakesitsimpletoentersetpoints,readmeteredvalues, monitor status and evaluatepowerquality.
Included in Launchpad is a documentarchiving and management systemthat ensures critical documentation isup-to-date and available when neededby automatically checking for anddownloading new versions of manuals,applications nates, specifications, andservicebulletins.
Viewpoint Monitoring
Viewpoint Monitoring is a simple-to-use, full-featured monitoring and datarecording software package for small
systems.ViewpointMonitoringprovidesacompleteHMIpackagethatinstantlyputscritical real-timedevicedataonyourPCthroughpre-configuredgraphicalscreenswiththefollowingfunctionality.
• Plug-&-PlayDeviceMonitoring
• SystemSingle-LineMonitoring&Control
• AnnunciatorAlarmScreens
• TrendingReports
• AutomaticEventRetrieval
• AutomaticWaveformRetrieval
Simultaneous Dual Communications Paths
EnerVista Viewpoint Monitoring Data Recording and Real-Time Status
Create tabular trending reports of usage data
Historical minimum and maximum values to understand fluctuations on the network
Real-time power values to instantly analyze system capacity
Building Automation System
Master Host or Multiple Masters
Web Browser
4
EPM 6010Building Automation Power Meter
GEDigitalEnergy.com
EnerVista Integrator
EnerVista Integrator is a toolkit thatallowsseamlessintegrationofGEMultilindevices intoneworexistingautomationsystems by sending GE device data toHMI,DCS,andSCADAsystems.IncludedinEnerVistaTMIntegratoris:
• OPC/DDEServer
• GEMultilinDrivers
• AutomaticEventRetrieval
• AutomaticWaveformRetrieval
DimensionsandMounting
UserInterface
EnerVista Viewpoint Monitoring Data Recording and Real-Time Status
Create graphical trending reports of usage overtime
Real-time metering values and phasors to verify device connection
10/100BaseTviaRJ45Connector
KYZPulseOutput
UniversalVoltageInputs
Current“Gills”
Only3.25”
IRDAPort
%LoadBar
VhPulse
ReadingTypeDesignator
Large.56”LEDs
Front View Side View Rear View Transducer
ScreenSelectors
AutoScaleIndicator
5
EPM 6010Building Automation Power Meter
GEDigitalEnergy.com
TechnicalSpecifications
VOLTAGE INPUTSUniversal Voltage Input•0-416VoltsLineToNeutral•0-721VoltsLinetoLineInputwithstandcapability–MeetsIEEEC37.90.1(surgewithstandCapability)ProgrammablevoltagerangetoanyPTratioSupports:3elementWYE,2.5elementWYE,2ElementDelta,4WireDeltaSystemsBurden:0.36VAperphasemaxat600V,0.014VAat120VoltsInputwiregaugemax(AWG12/2.5mm2)
CURRENT INPUTSClass10:0to11AmpsSecondary/5AmpsNominal/10AmpsMaxClass2:0to2AmpsSecondary/1AmpNominal/2AmpsmaxFaultCurrentWithstand:•100Ampsfor10Seconds•300Ampsfor3Seconds•500Ampsfor1Second.ProgrammableCurrenttoAnyCTRatioBurden0.005VAperphaseMaxat11Amps5mAPickupCurrentFrequency50Hzor60Hz+/-3HzaboveandbelownominalrangePassthroughwiregaugedimension:0.177”/4.5mm
ISOLATIONAllInputsandOutputsaregalvanicallyisolatedto2500VoltsAC.
SENSING METHODTrueRMSSamplingat400+SamplesperCycleonallchannelsmeasuredreadingssimultaneouslyHarmonic%THD(%oftotalharmonicdistoration)
UPDATE RATEWatts,VArandVA-100msecAllotherparameters-1second
POWER SUPPLYUniversalAC/DCSupply•90to265VoltsACand•100to370VoltsDC.Optional24to48VoltsDCSupply.Burden:10VAmax.
COMMUNICATIONS2ComPorts(BackandFacePlate):• IrDA(ThroughFaceplate)- ProtocolModbusASCII- ComPortBaudRate:56.7k- Address:1
•Ethernet(BackPanel)- 10/100BaseTviaRJ45connector- ProtocolModbusTCP- BACnet/IP
BACnet OBJECTS
VoltsA-N WhrNet
VoltsB-N TotalWhr
VoltsC-N PositiveVARh
VoltsA-B NegativeVARh
VoltsB-C PositiveWatts,3-Phase,AverageDemand
VoltsC-A PositiveVARs,3-Phase,AverageDemand
AmpsA NegativeWatts,3-Phase,AverageDemand
AmpsB NegativeVARs,3-Phase,AverageDemand
AmpsC PositiveWatts,3-Phase,MaxAverageDemand
TotalWatts PositiveVARs,3-Phase,MaxAverageDemand
TotalVARs NegativeWatts,3-Phase,MaxAverageDemand
TotalVA NegativeVARs,3-Phase,MaxAverageDemand
TotalPF VAs,3-phase,AverageDemand
TotalVAh VAs,3-phase,MaxAverageDemand
TotalVARh Volts,A-N%THD
VARhNet Volts,B-N%THD
Frequency Volts,C-N%THD
NeutralCurrent Amps,A%THD
WhrReceived Amps,B%THD
WhrDelivered Amps,C%THD
Thereare40pre-definedBACnetObjectsintheEPM6010’sBACnet/IPprotocol
METERING ACCURACY
Measured Parameters
Accuracy% of Reading Display Range
Voltage L-N 0.1% 0-9999ScalableVorkV
Voltage L-L 0.1% 0-9999VorkVScalable
Current 0.1% 0-9999AmpsorkAmps
+/- Watts 0.2% 0-9999Watts,kWatts,MWatts
+/-Wh 0.2% 5to8DigitsProgrammable
+/-VARs 0.2% 0-9999VARs,kVARs,MVARs
+/-VARh 0.2% 5to8DigitsProgrammable
VA 0.2% 0-9999VA,kVA,MVA
VAh 0.2% 5to8DigitsProgrammable
PF 0.2% +/-0.5to1.0
Frequency 0.01Hz 45to65Hz
%THD 5% 0-200%
%Load Bar 1-120% 10DigitResolutionScalable
PULSE OUTPUTFrontpanelWhinfaredtestpulseBackpanelWhpulseoutput
DIMENSIONS & SHIPPINGWeight:2lbsBasicUnit:H4.85xW4.82xL4.25Mountsin92mmDINandANSIC39.1RoundCut-outsShippingContainerDimensions:6”cube
ENVIRONMENTALStorage -20°Cto+70°COperating -20°Cto+70°CHumidity to95%RHNon-CondensingFaceplate Rating NEMA12(WaterResistant)
MountingGasketIncluded
COMPLIANCEIEC687(0.2%Accuracy)ANSIC12.20(0.2%Accuracy)ANSI(IEEE)C37.90.1SurgeWithstandANSIC62.41(Burst)IEC1000-4-2–ESDIEC1000-4-3–RadiatedImmunityIEC1000-4-4–FastTransientIEC1000-4-5–SurgeImmunity
APPROVALSISO Manufacturedtoan
ISO9001registeredprogram
UL/cUL ListedunderE200431CE ConformstoEuropean
CEstandards
g imagination at work
EPM 6010Building Automation Power Meter
120711-V3
GEDigitalEnergy215AndersonAve.Markham,ON,CanadaL6E1B3TollFree(NAOnly):1-800-547-8629Tel:905-294-6222Fax:905-201-2098email:[email protected]
GEDigitalEnergy.comBACnet is a registered trademark of American Society of Heating, Refrigerating and Air-ConditioningEngineers(ASHRAE).ModbusisatrademarkofSCHNEIDERAUTOMATION,INC.GE,theGEmonogram,MultilinandEnerVistaaretrademarksoftheGeneralElectricCompany.GEreservestherighttomakechangestospecificationsofproductsdescribedatanytimewithoutnoticeandwithoutobligationtonotifyanypersonofsuchchanges.Copyright2012,GeneralElectricCompany.
OrderingPL6010 * * * * DescriptionFrequency 5 50Hz-BACnet/IPCommunicatingMultimeter
6 60Hz-BACnet/IPCommunicatingMultimeterCurrent Inputs 5A 5Amps
1A 1AmpSoftware THD THD,LimitsAlarms&OneKYZPulseOutputPower Supply HI AC/DCPowerSupply(90-265)VACor(100-370)VDC
LDC LowVoltageDCPowerSupply(18-60)VDC Example – EPM 6010 for 60Hz system with 5 Amp secondary and an AC/DC Power supply. PL601065ATHDHI
EPM 6010 is available without a display as the EPM 6010T. Please see the online store for ordering information.