OUTLINE
1. Microwave and Radio Frequency (RF) Heating Principles
2. Established Applications in Food Processing
3. Development of Microwave Sterilization Technology for Pre-packaged Foods
Electromagnetic Spectrum
Very restricted bands
Can be used for ISM
applications
13.56 MHz(+/- 0.05%)
27.12 MHz (+/- 0.6%)
40.68 MHz (+/- 0.05%)
RF
915 MHz
2450 MHz Domestic Ovens
10 – 12 – 18 GHz (plasma)
MW
The wavelength l = c/f with c = 3.108m/s
f
l
SPECTRUM
•Generation of microwave
•Magnetron
•Magnetron
•Waveguide
•Microwave cavity (applicator)
•Domestic Microwave Oven (2450 MHz)
Microwave Cooking of Meat Patties (APV system)
RF Heating Systems
Food
Plate Electrodes in RF Heater
Food Dryer
Source: Strayfield, UK
Industrial Applications of RF Technology
- typical up to 85 kW per module
- Product temperature in electromagnetic field:
''21110563.5 Eft
TC p
=
- Dielectric property:
Dielectric heating of foods
- Contributions of dipole rotation and ionic conduction:
Loss factor
Dielectric constant
Multi-mode Systems
•Electric field pattern for a loaded microwave cavity at 2.4295 GHz.
•(Chan and Reader, 2000)
Single - mode Systems
TM010 cavity resonator, 915 MHz (adopted from Regier and Schubert)
How Does RF or Microwaves Heat Foods?
Space charge polarization Orientation polarization
Alternating Electric field
Mechanism of Dielectric Heating
MWRF
Ref: Tang et al., 2002, Scientific Press, New York
Ref: Wang et al.,2003. J. Food Eng. 57: 257-268.
Penetration Depth (mm)
RF Microwaves
2. Industrial Microwave (MW) and Radio
Frequency (RF) Technologies
-- Better quality
-- Reduced process times
-- New products?
Cooking of desserts in pots
Microwave Tunnel 22 000 Pots / hour Power : 144 KW.
MW COOKING DESSERTS
Nutripack (a French Company) solution with valve Valvo-PackTM
The valve allows a thermal treatment and the cooling of the product in the packing without
counter-pressure.
The valve is adhesive and is installed on the upper part (heat sealing film, cover…) of a
packing (plastic, metal, paper, cardboard) that has been previously pierced.
Opening limit : 10 mbar 3 mbar
Closing limit : 5 mbar 2 bars
MW COOKING/PASTEURIZATION OF VEGS
From their website:
MicVac develops, markets and sells two methods
for processing and packaging convenience food.
Both solutions (for pasteurised and unpasteurised
foods respectively) use a valve that offers several
benefits for both the producer and the consumer.
The MicVac method is based on the principle of
cooking and pasteurising food using microwaves
directly in the sealed consumer package. The film
cover on the package has a valve that opens
during cooking, releasing the overpressure in the
form of steam and oxygen. After cooking, the
valve closes and a natural vacuum is created in
the package – another of the product’s many
advantages.
•http://www.micvac.com/
•A similar concept developed by MicVac, Sweden
EXAMPLES OF PRODUCTS
MW COOKING/PASTEURIZATION
50kW RF Post Baking Unit - Courtesy of Fox’s Biscuits, UK
Wokingham, UKRF Finish Drying of Bakery Products
Moisture profile at exit of an industrial bakery
oven, and after RF drying for 5 mins
1.25
1.45
1.65
1.85
2.05
Working Side Middle Non-working Side
Mo
istu
re %
BD
W
Before RF After RF At Packing
RF Post-Baking
Virtually Eliminates Checking!
Sponge Products
• Reduces Mold Spores• Increases Shelf Life• Increases Production
RF DRYING OF BAKERY
PRODUCTS• Appetisers snack
• Meringue
•Puff pastry
•Breakfast cereal
•Bread crouton
•Sponge product
•Pretzel
•Short bread
•Profiterole
Manufacturers using RF
Heating and Drying
• Kraft (Nabisco) (USA)
• United Biscuits (UK)
• Kelloggs (Keebler) (USA)
• Fox’s Biscuits (UK)
• Weetabix (UK, Canada)
• Arnotts (Australia/ New Zealand/ Indonesia
• National Biscuits (S.Africa)
• Safeway (USA)
• Ferrero (Italy)
• Dancake (Portugal)
• Ulker (Turkey)
• Pepperidge Farms (USA)
• M&M Mars (USA)
• Parle (India)
• Britannia (India)
• Crown (Korea)
• Horizon Biscuits (UK)
• United Biscuits/Danone (Lu –France, Bagley Argentina)
• Tong Yang (Korea)
• Morinaga (Japan)
• Dare Foods (Canada/USA)
• Barilla (Italy)
• ETI (Turkey)
• Ralston Purina (Bremner) (USA)
• Griffin (New Zealand)
Approximately 500 RF food processing systems
sold over 37 years
3. Development of Microwave Sterilization
Technology for Pre-packaged foods
(~50 years)
All past MW sterilization systems used 2450
MHz
Conventional Retorting Relies on Heat
Convection and Conduction in Foods
Retort
Convection
Target: C. botulinum spores
2450 MHz microwave heating system for food in plastic
pouches at US Army Natick Soldier Center in 1970
A Multi-mode 2450 MHz Microwave Cavity
• Microwave pasteurization equipment with module
open to show alternating placement of magnetrons
(Berstoff, 1992)
Microwave pasteurization line for prepared meals
(Berstoff, 1992)
Microwave sterilization unit with external covering removed
(overpressure of 2.5 bar,OMAC, 1992)
Continuous microwave sterilization system
(OMAC, 1992)
Otsuka plant
in Japan (2008)
TOP’S FOODS
Olen, Belgium (2000)
The 2nd generation Microwave Sterilization
System2000
•The 3d Generation of Microwave Technology at
Tops Foods, 2004
Sterilized products produced by TOPS Foods
MW pasteurized, processed to 80C
shelf-life 35 days at 7C
MW sterilized, shelf-life 1 year
at room temperature
4. Research on Microwave Sterilization
Technologies at Washington State University
4. Engineering and Scientific Challenges in
Developing MW Sterilization Processes
1. Technology/systems to provide stable
electromagnetic field patterns with high
energy efficiency
Single –mode, high coupling efficiency
2. FDA Approval
Stability of system and processes
Scientific base/means for process development
Food Safety
3. High quality foods
4. Scaling-up and economic viability
MW STERILIZATION CONSOTIUM (2001-)
Washington State University
Microwave Company: Ferrite Component, NH
Food Packaging Companies:
Rexam Container, MO
Graphic Packaging, CO
Food Processing Companies:
Kraft Foods, ILL
Hormel, MN
Masterfoods (MARS USA), CA
Ocean Beauty Seafood Inc., WA
Technical Consultant: NPA
Supported by DoD DUST Program and US Army Natick Soldier
Center
System development
Computer simulation
Process development
Industrial implementation
Development of Microwave Sterilization Technology
Microbial studies
Scaling-upFDA Approval
waveguide
cavity
0 phase shift
WSU 915 MHz Single-Mode 10 kW Pilot Scale Sterilization
System (2001-2008)
Steps involved in identification of cold and hot spots with mashed
potato sample
M-2 Kinetics
Fo vs M-2 yield relationship
Computer vision to measure
M-2 color of processed
trays.
Checking repeatability of
hot and cold spots with different
tray sizes and level of salt
Identification of cold/ hot location
For different tray size.
Verification of location
Using fiber optics probes
MW sterilization of salmon
April 15, 2003
(Run-1)
0
20
40
60
80
100
120
140
0.00 2.00 4.00 6.00 8.00 10.00 12.00
time [min]
para
mete
rs
temperature of salmon
circulating water tempture
F0=8.4MW heating: 2.4 min;
Total processing time: 10 min.
77 min heating time (steam at 247
F)
Change of Shear Force in Pink Salmon Fillet Heated at 121˚C
30
50
70
90
110
130
150
170
0 20 40 60 80 100 120 140
Cooking time (min)
Sh
ea
r fo
rce
(N
)
Eggs
Mashed Potato
Microwave sterilized salmon and fried rice
56
Process time
(min)
Max cook value
Min Cook value
Ideal 2.4 22 22
Retort 27+4 279 78
Microwave 3.9+4 36 32
•Maximum and minimum C values for food in a 10 oz tray after
• a F0=6 process, water temp=121 C
•C values for food in a 10 oz tray after a F0=6 process, water
temp =125 C
Process time (min)
Max cook value
Min Cook value
Ideal
Retort
6
33+4
39
212
39
93
Microwave 9+4 58 50
Sensory and self-life studies at US Army
Natick Soldier Center
50 trays chicken
were produced for
Natick in January
2004
– Chicken product:
Natick evaluation,
shelve study and
taste panels
Chicken Breast, OVERALL Acceptability
Averages over 6 months storage at 100o F
y = -0.0796x + 6.7086
R2 = 0.6015 (Microw ave)
y = -0.0865x + 5.4943
R2 = 0.946 (Retort)
0
1
2
3
4
5
6
7
8
0 1 2 3 4 5 6 7
Months in 100o F Storage
He
do
nic
sc
ore
(1-9
sc
ale
)
Microwave
Retort
Linear (Microwave)
Linear (Retort)
WSU 2nd generation system developed for FDA approval- four single mode cavities, 40 kW max MW power
Potential applications for microwave sterilization/pasteurization technologies
- new processes
- new products
- new markets
For more information
http://www.microwaveheating.wsu.edu/
MW and RF Technologies are much more
complicated than conventional methods.
Successful development of new applications
requires extensive R&D efforts based on good
understanding of MW and RF heating principles
and the systems.
Pilot-scale studies are necessary for scaling up to
industrial processes
Thank You