meet USP regulations Cyto Cal Flow Cytometry Calibration and Setup Particles Particle Solutions for USP <729>, <788> and <1027> Ensuring optimal particle counter, sizer and flow cytometer instrument performance is crucial to your product development and ability to comply with ISO and USP <729>, <788> and <1027> regulations. With our uniform, NIST traceable size standards, count controls, calibration and set-up particles, you can calibrate to ensure the lasers and optics are performing precisely align to make sure the laser and flow cell is focused count for absolute cell counting make sure the instrument is sizing and measuring properly As a result, you can be confident your instruments are consistently delivering the precise and accurate data you require for USP compliance. measure properly

Upload: others

Post on 01-Jan-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: meet USP regulations - Thermo Fisher Scientifictools.thermofisher.com/content/sfs/brochures/FL... · meet USP regulations Cyto Cal Flow Cytometry Calibration and Setup Particles Increase

meet USP regulations

Cyto Cal Flow Cytometry Calibration and Setup Particles Increase throughput and precision

Particle Solutions for USP <729>, <788> and <1027>

Ensuring optimal particle counter, sizer and flow cytometer instrument performance is crucial to your product development and ability to comply with ISO and USP <729>, <788> and <1027> regulations. With our uniform, NIST traceable size standards, count controls, calibration and set-up particles, you can• calibrate to ensure the lasers and optics are performing precisely• align to make sure the laser and flow cell is focused• count for absolute cell counting• make sure the instrument is sizing and measuring properlyAs a result, you can be confident your instruments are consistently delivering the precise and accurate data you require for USP compliance.

measure properly

Page 2: meet USP regulations - Thermo Fisher Scientifictools.thermofisher.com/content/sfs/brochures/FL... · meet USP regulations Cyto Cal Flow Cytometry Calibration and Setup Particles Increase

Clinical Diagnostics 46360 Fremont Blvd. USA: 1-800-232-3342 [email protected] Technology Fremont, CA International: 1-510-979-5000 94538

FL0000.0_00/00

thermoscientific.com/particletechnology © 2012 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.

USP Number

USP Section Title/Requirement

USP Particle Requirement

Particle Instrument

Measurement Method Technique Thermo Scientific

Particle: Cat. Number

729

Globule size distribution in lipid injectable emulsions / Method 1-Light Scattering

100, 250 and 400 nm Particle sizer PCS / QELS Sizing 3000 Series Size Standards: • 3100A • 3240A • 3400A

788

Particulate matter in injections / Method 1-Light obscuration particle count test

Particles of known size between 10 µm and 25 µm with a count < 6000 per container ≥ 10 µm and < 600 per container ≥ 25 µm Test 1b - <100 mL

Particle counter

Light scatter, laser scatter, light blockage

Counting Pharm-trol Count Controls: • CS-BX • CS-PK

1027

Flow cytometry / Instrument set-up

Standardizing PMT Flow cytometer Laser scatter, fluorescence scatter

Counting Cyto-Cal Multifluor + Violet Intensity Calibrator: • FC3MV

1027Flow cytometry / Cell enumeration

Standardizing cell count

Flow cytometer Laser scatter, fluorescence scatter

Counting Cyto-Cal Absolute Count Control: • FC7

1027

Flow cytometry / Quality and Standardization (Standards)

Type I - Alignment standards

Flow cytometer Laser scatter, fluorescence scatter

Counting Cyto-Cal 488 and 633 Alignment Particles: • FA30 • FA3R

1027

Flow cytometry / Quality and Standardization (Standards)

Type II - Reference beads

Flow cytometer Laser scatter, fluorescence scatter

Counting Cyto-Cal Multifluor + Violet Intensity Calibrator: • FC3MV

1027

Flow cytometry/Flow Cytometry applications for cellular samples and cell therapy products

Bead-based immunoassays

Flow cytometer Laser scatter, fluorescence scatter

Counting Cyto-Plex Carboxylated Particles: • FMCR01-12 • FM5CR01-12

35+ years of expertise

The chart below shows recommended particles for optimizing instrument performance in accordance with specific USP regulations.

Count ControlsParticles for calibrating and checking particle counter performance and validating results. For more information, request PF1004.1 brochure or visit website.

NIST Traceable Size StandardsParticles for developing, standardizing and validating particle counting and sizing instruments. For more information, request PF1004.1 brochure or visit website.

Rigorous QC standards

Particles for USP Regulatory Compliance

About the USP

The United States Pharmacopeial Convention (USP) is a scientific nonprofit organization that sets standards for the identity, strength, quality, and purity of medicines, food ingredients, and dietary supplements manufactured, distributed and consumed worldwide. In 2007, the USP, European Pharmacopoeia (Ph. Eur) and Japan Pharmacopoeia (JP) harmonized the <788> methods, definitions and limits.

Flow Cytometry ParticlesParticles for calibrating and set, alignment, and absolute cell counting of all makes and brands of flow cytometers. For more information, request PF4001.1 brochure or visit website.