medical gas central piping system
DESCRIPTION
Medical GasTRANSCRIPT
Go Japanese Page
MEDICAL GAS CENTRAL PIPING SYSTEM
Supports the stable supply of medical gases more safely and more securely.
The medical gases used in ahospital are life-supportingelement that gives directinfluence in maintaining the lifeof a patient. Therefore, at thesections where the medicalgases are used, the medical gasmust be clean, highly pure andsupplied under stablepressure.Our medical gas systemhas cleared those regulationsand standards as well as passingour strict company standard. Thesystem has a thoroughgoingcolor coordination according tothe kind of gas, an audio-visualmonitoring system capable ofchecking the situation, and adevice to prevent crossconnection at medical gas outletbased on the concept, "moresafely" and "more securely".
MEDICAL GAS SUPPLY
M A N I F O L D
LIQUID OXYGEN FULLY AUTOMATIC CHANGE-OVERMANIFOLD MLh
LIQUID OXYGEN AUTOMATIC CHANGE-OVER MANIFOLDLGBh
FULLY AUTOMATIC CHANGE-OVER MANIFOLDMAh
AUTOMATIC CHANGE-OVER MANIFOLD HCM
A I R S U P P L Y S T A T I O N
PACKAGED TYPE AIR SUPPLY STATION (MEDILINE AIRCUBE)
SEPARATE TYPE AIR SUPPLY STATION
V A C U U M S T A T I O N
PACKAGED TYPE VACUUM STATION (MEDILINE VAC) SEPARATE TYPE VACUUM STATION
SHUT OFF VALVE / COLOR PIPES
ZONE SHUT OFF VALVE MAIN SHUT OFF VALVE
COLOR PIPES
ALARM SYSTEM
To maintain a stable supply of medical gases,it is necessary to establish amonitoring system which surely traces the flow of invisible gas from thesource of supply through piping to the section to use the gas.We have beenoffering various monitoring systems which are possible to grasp theinformation of supply source such as the amount of gas remaining in the rightand left banks of manifold and the operating condition of supply station and
the pressure of gas supplied at each area of section where the gas is used. Inthis system, a supply pressure down and a supply station's malfunction aresurely grasped by audio-visual tracing.
MAIN ALARM PANEL AREA ALARM PANEL
TERMINAL UNIT
The medical gas outlet which the medical staff such as doctors and nursesuse for daily medical care must be so designed as not to allow a crossconnection to a different medical gas not intended.We have developed a pinguide system to prevent a cross connection mechanically and, furthermore,we adopted a visual identification system by use of colors respectivelydesignated to the exclusive kind of gas, obtaining a remarkable effect. In orderto prevent a cross connection when attaching a medical gas outlet valve at thetime of installation or maintenance, a pin guide system is adopted to the valvebase of wall type outlet, and DISS standard is applied to the hose connectingsection in the case of reel type and ceiling type outlets.
W A L L T Y P E O U T L E T
CPS TYPE OUTLET NSV TYPE OUTLET
S P E C I A L T Y P E O U T L E T
CEILING COLUMN (RETRACTABLE) MOTOR DRIVEN CEILING COLUMN
CEILING TYPE OUTLET REEL TYPE OUTLET
CEILING MODULE
NITROGEN CONTROL UNIT
ANESTHETIC GAS SCAVENGING SYSTEMFLOW CONTROL UNIT
SECONDARY EQUIPMENT
The secondary equipment which is used by connecting to the medical gasoutlet must have high accuracy to control the medical gas flow correctly andsure performance to maintain this function.
HUMIDIFIER WALL SUCTION UNIT