measuring probes, digital displays and … measuring probes, digital displays and bench tables the...

44
95 MEASURING PROBES, DIGITAL DISPLAYS AND BENCH TABLES The Sylvac linear probes are based on the capacitive principle characterized by a high degree of accuracy also on long measuring ranges up to 50mm. The probes are used as measuring elements to be placed on tables, supports, bench tables, special mechanical devices or multi-gauging fixtures. The probe signal is processed in a display unit. Sylvac offers several of them.Benefiting from the high degree of accuracy of its probes and with the aim to measure small machined parts typically used in watches, Sylvac developed a whole series of benches and tables. These supports are conceived for the control of internal, external, heights, grooves etc, starting from a few tenths to 70mm. Absolute capacitive measuring system Digital display units RS232 and USB Operational temperature 0 to +50°C

Upload: hanhu

Post on 23-May-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

95

MEASURING PROBES, DIGITAL DISPLAYS AND BENCH TABLES

The Sylvac linear probes are based on the capacitive principle characterized by a high degree of accuracy also on long measuring ranges up to 50mm. The probes are used as measuring elements to be placed on tables, supports, bench tables, special mechanical devices or multi-gauging fixtures.

The probe signal is processed in a display unit. Sylvac offers several of them.Benefiting from the high degree of accuracy of its probes and with the aim to measure small machined parts typically used in watches, Sylvac developed a whole series of benches and tables. These supports are conceived for the control of internal, external, heights, grooves etc, starting from a few tenths to 70mm.

Absolute capacitive measuring system

Digital display units RS232 and USB

Operational temperature 0 to +50°C

96

P2B

P5

P10

P25

Measuring probes

DESCRIPTION

Clamping stem Ø 8-h6

Interchangeable cablesup to 15 m (standard 1.5 m)

P2 and P5: clamping stem Ø 8-h6Measuring anvilInterchangeable contact point M2.5, stainless steel with TC ball

Fixed cable (standard 1.5 m)

97

15.7

5

Ø h68

71.4

45.7

23.2

P2B

Measuring probes

DIMENSIONAL DRAWINGS

98

90

0.1

001 P

5

90

0.1

003 P

5V

90

0.1

006 P

5L

90

0.1

012 P

10S

90

0.1

014 P

10L

90

0.1

025 P

25

90

0.1

027 P

25S

90

0.1

050 P

50

90

0.1

008 P

5V

L

90

0.1

010 P

10

90

0.1

016 P

10LS

64 64 64 64 64 40 50 40 50 40 50 40

80

0.0

994 P

2B

LISTING OF ALL MODELS

RANGE

2 mm

5 mm

10 mm

25 mm

50 mm

EXECUTION

Plain bearing

B- Ball bearing

V- Vacuum lifter

L- 90 degrees cable

S- with rubber boot

MECHANIC

Diameter 8 mm h6

Diameter 12 mm

Measuring anvil M2.5

LIFTING

Integrated

Separate accessories

PROTECTION IP

Protection rating IP (IEC 60529)

Measuring probes

99

P2B

0.25

0.8

0.2

3.4

P5

0.7

1

0.2

3.7

P10

0.5

1

0.2

4.1

P25

0.8

1.2

0.2

9.6

P50

1

2.5

0.4

15.3

P2B

0.60-0.75

---

---

---

0.70

P5

0.60-1.20

---

0.20-0.25

1.00-1.80

0.70

P10

0.60-0.80

< 0.10

0.20-0.25

0.70-1.50

0.60

P10S

0.70-1.25

---

---

---

---

P25

0.60-1.00

< 0.15

0.20-0.30

0.70-1.60

0.30

P25S

0.65-1.4

---

---

---

---

P50

0.70 - 1.7

---

---

---

0.25

1) with master unit

TECHNICAL SPECIFICATIONS

MEASURING FORCE

Pre-travel mm

Max. Error 1) µm

Repeatability µm

Moving mass g

Standard N

Minimum N

Low N

High N

Lateral max N

Tolerance ± 20%, measuring probe in vertical position, outgoing spindle.

BASIC INSTRUMENT

Probe according to technical specifications

Calibration certificate

Cable 1.5 m

Stainless steel contact point with tungsten carbide ball Ø 2 mm (905.2204)

Measuring probes

100

APPLICATIONS

P5 probes connected to a D50S unit measuring the external diameter of a shaft

P25 probe connected to a D80S unit measuring the height of a part

Combined probes for the measurement of several heights

Measuring probes

905.2204

901.2003

901.2004

901.2005

901.2006

901.2010

901.2011

901.2012

901.2013

901.2014

101

P50P25P10P5P2

ACCESSORIES

Stainless steel contact point M2.5

with TC ball probe (other contact

points, see page 50)

Rubber boot and contact point set

Rubber boot and contact point set

Lifting device with photo-cable

Lifting device with photo-cable

Pneumatic lifting device

Pneumatic lifting device

Tube Ø 4 mm / 2 mm, Length to be

specified

Tube Ø 6 mm / 4 mm, Length to be

specified

Double tube diameter 2 x 4 mm /2 mm,

Length to be specified

Measuring probes

102

P50P25P10P5P2

ACCESSORIES

Extension 3 m

Cable 1.5 m

Cable 1.5 m

Cable 1.5 m

Cable 1.5 m bent

Cable 1.5 m

Cable 1.5 m bent

Adapting socket + screw

901.5001

901.5002

901.5012

901.5022

901.5032

901.5042

901.5052

905.2231

Measuring probes

2 2 1 1 8 2 (4) 2 2

1 / - 1 / 6

1 1 1 1 1 2 1 1

81) 242) 643)

644)

15)

5)

*) *)

103

D50

S

D50

S P

RO

D60

S P

RO

D80

S

D20

0S

D30

0S *)

D30

2

D30

2 a

Digital display

TABLE OF CORRESPONDENCES

Direct input

Additional input

Output

Functions

Probes

RS instruments

External contact

Probes

USB instruments

Analog display

RS 232

RS 485

USB

Opto-coupled output

Analogic

Direct zero setting

Direct zero setting per channel

Selection of resolution

Selection of measuring direction

PRESET

Tolerance indicators

Classification (max 8 classes)

Min, Max, Delta

A ± B

A ± B ± C

Scanning

Histogram

Statistics

Memorization

Simultaneous display of the channels

Dynamic measurement

Calibration (max. 25 points)

1) with unit (s) additional (s) D1082) with 3 D200S units 3)* with units D200S or D3024)* with USB-Hub powered5) with analog display unit

* Maximum 64 mixed instruments on D300S

104

D50S PRO925.1142

926.5130 926.8116

925.5609

926.5130

926.

5131

Digital display

DESCRIPTION

Resolution up to 0.0001 mm

Direct functions

Combination of channels A+B; A-B

Great clear and luminous display

Feet

S_View D50S

Correction of linearity.Higher precision

105

!

"

#

$

%

&

'

(

)

11

&

! " # $ %

' ( )

11

DISPLAY

Conversion mm/inch

Selection of resolution

Selection of measuring direction

REL and ABS measurement

PRESET function

Data sending

Selection of measuring mode: channel 1 ;channel 2 ; channel 1-2 ; channel 1+2

TECHNICAL SPECIFICATIONS

Type

Max. Error µm

Repeatability µm

Sizes mm

Weight kg

Case

Protection according to IEC 60529

S_Connect

Programmable by PC

804.1050

D50S

P2 : 1.5 / P5 : 1.6 / P10 : 1.6 / P25 : 1.9 / P50 : 3.9

P2 : 0.2 / P5 : 0.2 / P10 : 0.2 / P25 : 0.2 / P50 : 0.4

180 x 75 x 50

0.3

Terblend Plastic

IP40

RS232 1)

Probe inputs

Power supply connection

External contact connection

RS232 input/output

Unit according to technical specifications

Feet (pair)

Charging unit according to country (904.4000)

Instruction manual

BASIC INSTRUMENT

1) see cables chapter

Digital display S_View D50S

804.1060

D50S PRO

P2 : 0.5 / P5 : 0.6 / P10 : 0.6 / P25 : 0.8 / P50 : 1.5

P2 : 0.2 / P5 : 0.2 / P10 : 0.2 / P25 : 0.2 / P50 : 0.4

180 x 75 x 50

0.3

Terblend Plastic

IP40

RS232 1)

106

APPLICATIONS

Simple measurement with one probeMeasuring a shaft

COMBINATIONS OF PROBES

Diameter = 1+2

Difference = 1-2

Individual measurement

Digital display S_View D50S

107

MAX. 2

2x

P2...P50

POSSIBILITIES OF CONNECTION

RS232C PROBE

SW1

P2...P50

Digital display S_View D50S

S_View D60S PRO

108

925.1142

926.5130 926.8116

925.5609

926.5130

926.

5131

mini-USB

926.6001

Resolution up to 0.0001 mm

Direct functions

Selection of the functionsNOR / MIN / MAX / DELTA

Great clear and luminous display

Feet

Analog displayScale range

Correction of linearity.Higher precision

Digital display

DESCRIPTION

Analog display(optional)

S_View D60S PRO

804.1070

109

!

"

#

$

%

&

'

)

11

(

12

13

'

! " # $ %

( )

1312

&

11

DISPLAY

Selection of measuring direction

Selection of resolution

Preset function / Preset setting

Nominal and tolerances setting

Zero setting fo analog display or Min-Max

Data transmission

Tolerances range for analog display

Probe measuring mode: NOR (static) / MIN / MAX /DELTA

Probe input / Analog input

Power supply connection

External contact connection

USB-mini

RS232 input / output

D60S PRO

P2 :0.5 / P5 : 0.6 / P10 : 0.6 / P25 : 0.8 / P50 : 1.5

P2 : 0.2 / P5 : 0.2 / P10 : 0.2 / P25 : 0.2 / P50 : 0.4

Display unit: 180 x 75 x 50 Analog unit : 50 x 48.5 x 41.5

0.3

Terlend plastic

IP40

RS232 / USB mini 1)

*

Type

Max. Error µm

Repeatability µm

Sizes mm

Weight kg

Case

Protection according to IEC 60529

S_Connect

Programmable by PC

BASIC INSTRUMENT

Digital display

TECHNICAL SPECIFICATIONS

Unit according to technical specifications

Feet (pair)

Charging unit according to country (904.4000)

Instruction manual

S_View D60S PRO

804.1071 804.1072

50 x 48.4 x 41.5

Aluminium

IP40

110

804.1071 804.1072

Digital display

APPLICATIONS

ANALOG UNIT

Model

Overall dimensions mm

Case

Protection according to IEC 60529

Needle axis at 6 o’clock Needle axis at 12 o’clock

PS17 bench with D60S PRO and analog display

Measuring stand with P2B, D60S PRO and analog display

S_View D60S PRO

111

MAX.1MAX.1

P2...P50

Digital display

POSSIBILITIES OF CONNECTION

112

925.1142

926.5130 926.8116

925.5609

926.5130

926.

5131

DESCRIPTION

CCFL graphic display with backlight

Ergonomic keyboard

Adjustable base

Digital display S_View D80S

113

!

"

#

$

%

&

'

)

11

12

13

(

15

14

! "# $

% & ' (

14) 11 12 1315

Activation of analog display

Selection of unit mm/inch

Selection of resolution

Tolerance indicators with LED

PRESET function

Display Min/Max/Delta

Data sending

Zero setting

Configuration channel

RS232 input/output

Analog and digital Opto-coupled output

External power supply connection

Capacitive probe input

Connection D102/D108 unit

External contact connection

DISPLAY/SOFTWARE

TECHNICAL SPECIFICATIONS

Type

Max. Error µm

Max. Error 1) µm

Repeatability µm

Sizes mm

Weight kg

Case

Protection rating according to IEC 60529

S_Connect

Programmable by PC

804.1080

D80S

P2 : 1.5 / P5 : 1.6 / P10 : 1.6 / P25 : 1.9 / P50 : 3.9

P2 : 0.5 / P5 : 0.6 / P10 : 0.6 / P25 : 0.8 / P50 : 1.5

P2 : 0.2 / P5 : 0.2 / P10 : 0.2 / P25 : 0.2 / P50 : 0.4

227 x 77 x 132

0.8

Terlend Plastic

IP50

RS232 2)

1) Probe and unit calibrated2) see cables chapter

Digital display S_View D80S

114

Unit according to technical specifications

Base

External contact (foot-pedal)

Charging unit according to country (904.4000)

Instruction manual

BASIC INSTRUMENT

APPLICATIONS

Using 3 measuring channels with 3 separated probes

Measurement of 4 dimensions on 4 channels with one single probe

Digital display S_View D80S

MAX. 8x

1x 1x

MMAAXX.. 88xx

11xx 11xx

115

MAX. 8

8x1x

MAX. 1

1x

P2...P50P2...P50

CONNECTION DIAGRAM

RS232C

PROBE

SW1

OUTPUT

Digital display S_View D80S

3x33xx

116

1x

MAX. 8

8x

POSSIBILITIES OF D110V LIFTER

RS232C

SW1

OUTPUT

Digital display S_View D80S

117

1x

MAX. 8

8x

P10/P25 P50*901.2010 *901.2011

*

OUTPUTOUTPUTOUTPUT

POSSIBILITIES OF D110 LIFTER

RS232C

SW1

Digital display S_View D80S

118

925.1142

926.5130 926.8116

925.5609

926.5130

926.

5131

DESCRIPTION

CCFL graphic display with backlight

Ergonomic keyboard, protected from water and coolants

Adjustable base

Digital display S_View D100S

119

!

"

#

$

%

&

'

(

)

11

12

13

15

14

16

17

18

! "# $%

&' ( )

1718

11 12 13 1514 16

Analogic scale display

Selection of unit mm/inch

Selection of resolution

Statistics

Tolerance limits shown by LED

Min/Max/Delta display

PRESET function

Memorization of measured values

Data sending

Scanning

RS232C input/output

RS232 instrument input

Opto-coupled digital output

Centronics output for printer

2 connections for external contact

Capacitive probe input

Connection of D102/D108 unit

Connection of external power supply

DISPLAY

TECHNICAL SPECIFICATIONS

Type

Max. Error µm

Max. Error 1) µm

Repeatability µm

Sizes mm

Weight kg

Case

Protection rating according to IEC 60529

S_Connect

Programmable by PC

804.1101

D100S

P2 : 1.5 / P5 : 1.6 / P10 : 1.6 / P25 : 1.9 / P50 : 3.9

P2 : 0.5 / P5 : 0.6 / P10 : 0.6 / P25 : 0.8 / P50 : 1.5

P2 : 0.2 / P5 : 0.2 / P10 : 0.2 / P25 : 0.2 / P50 : 0.4

227 x 77 x 132

1.3

Terlend Plastic

IP50

RS232 2)

1) Probe and unit calibrated2) see cables chapter

Digital display S_View D100S

120

Unit according to technical specifications

Base

External contact (foot-pedal)

Charging unit according to country (904.4000)

Instruction manual

BASIC INSTRUMENT

APPLICATIONS

Mixing of probes and hand toolsMulti-gauging application Multi-gauging application

Digital display S_View D100S

121

MAX. 1

1x

MIXED

MAX. 2 MAX. 1

1x

P2...P50

POSSIBILITIES OF CONNECTION

RS232C

PROBE

SW1

OUTPUT

RS232

SW2

10 V

0 VCENTRONICS

Digital display S_View D100S

122

MIXED

MAX. 64

8x

MAX. 64

8x

POSSIBILITIES OF CONNECTION WITH ACCESSORIES

RS232C

PROBE

SW1

OUTPUT

SW2

10 V

0 VCENTRONICS

Digital display S_View D100S

123

MAX. 48

16x

MIXED

MAX. 64

3x 4x

MAX. 64

16x

50/100 mm

S229

905.2227

POSSIBILITIES OF D110V PNEUMATIC LIFTER

RS232C

PROBE

SW1

OUTPUT

RS232

SW2

10 V

0 VCENTRONICS

Digital display S_View D100S

124

*

MAX. 48

16x

MIXED

MAX. 64

3x 4x

MAX. 64

16x

905.2217

12.5/25 mm

S229 P10/P25

905.4217

5/12.5 mm

S233 P50*901.2010 *901.2011

PROBE

POSSIBILITIES OF D110 PNEUMATIC LIFTER

RS232C

SW1

OUTPUT

RS232

SW2

10 V

0 VCENTRONICS

Digital display S_View D100S

125

S_View D300S

804.1210

Digital display

DESCRIPTION

Large touchscreen 8.5’’

Ergonomic keyboard protec-ted against liquids

Ergonomic interface configurable according to your needs

126

11

6 16

12

15

14

!

"

#

$

%

&

'

(

)

11

12

13

15

14

16

13

1

2

3

4

5

7

8 9 10

S_View D300S

Touchscreen 8.5 ‘‘

ON/OFF button for LCD

Numeric keyboard

Navigation keyboard

ON/OFF switch

Capacitive probes inputs

RS-232 instrument input

RS-485 input

VGA output

Opto-coupled digital output

2 inputs for external contacts

RJ-45 Ethernet

USB Device connector

6 USB Host inputs

24VDC connector

Audio jack connector

Modele

Max error µm

Max. Error 1) µm

Repeatability µm

Frequency of measure meas/sec

Overall dimension mm

Weight kg

Case

Protection rating according to IEC 60529

S_Connect

Programmable by PC

804.1300

D300S

P2 : 1.5 / P5 : 1.6 / P10 : 1.6 / P25 : 1.9 / P50 : 3.9

P2 : 0.5 / P5 : 0.6 / P10 : 0.6 / P25 : 0.8 / P50 : 1.5

P2 : 0.5 / P5 : 0.6 / P10 : 0.6 / P25 : 0.8 / P50 : 1.5

P2 : 5 / P5 : 5 / P10 : 5 / P25 : 5 / P50 : 2.5

330 x 175 x 77

3.3

Steel / Plastic

IP40

RS232 / USB

Digital display

INTERFACE | HARDWARE

TECHNICAL SPECIFICATIONS

1) Probe and unit calibrated

127

S_View D300S

Unit according to technical specifications

Table base

External contact (foot-pedal)

Charging unit according to country (804.4000)

Instruction manual

Multi-gauging measurement using D200S interface and D300S display

Many instruments connected to the D300S with live displayed colored values to indicate the tolerances

Measurement using PS17 benchAutomatic detection of measuring channel and automatic switch to the right window

Digital display

BASIC INSTRUMENT

APPLICATIONS

128

6x USB1x RS-232

2x8x

S_View D300S

D200S

Digital display

MAX. 6Power supplied by D300S

MAX. 64Power supplied

by USB-HUB

MAX. 64Via D200S

POSSIBILITIES OF CONNECTION WITH ACCESSORIES

PROBE

USB

SW1

OUTPUT

USB

SW2

USB

129

S_View D300S

D302

32x2x

P2...P50

Digital display

POSSIBILITIES OF CONNECTION WITH ACCESSORIES

MAX. 64Via D302

USB

SW1

OUTPUT

USB

SW2

USB

PROBE

130

804.1210

DESCRIPTION

Tolerance indicators

Connection by USB (2x)or RS232 (1x)

Opto-coupled digital output rack

Multiplexer unit S_View D200S

8 inputs for Sylvac probes

Software allowing the treatment of up to 24 channels simultaneously (bargraph)

Connection by USB (2x)or RS232 (1x)

131

DISPLAY/SOFTWARE

Selection of unit mm/inch

Selection of resolution

PRESET function

Sending Data

Tolerance indicators with LED

Min/Max/Delta display

Individual selection of measuring direction

Switchable digital/bargraph display

Global tolerance status of the measured part

Programming channels screen

Sending Sequences of Data

External contact configuration

Electrical external contact configuration

Open / Save configurations

Transfer configuration to D200S unit

TECHNICAL SPECIFICATIONS

Type

Max. Error µm

Repeatability µm

Frequency of measurement

Sizes mm

Weight kg

Case

Protection rating according to IEC 60529

S_Connect

Programmable by PC

804.1200

D200S

P2 : 1.5 / P5 : 1.6 / P10 : 1.6 / P25 : 1.9 / P50 : 3.9

P2 : 0.2 / P5 : 0.2 / P10 : 0.2 / P25 : 0.2 / P50 : 0.4

200 values /second

304 x 171 x 61

1.2

Aluminium profile, Terlend plastic, ABS and aluminium vanished

IP50

USB / RS232 1)

1) see cables chapter

S_View D200SMultiplexer unit

132

Instrument according to technical specifications

Feet for use in vertical position

Charging unit according to country (904.4000)

PC Connection cable type USB (804.1210)

CD with D200S software

Instruction manual

BASIC INSTRUMENT

APPLICATIONS

Dynamic measurement of several diameters, (OD and ID) of a shaft

S_View D200SMultiplexer unit

Multi-gauging application

133

1x

MAX. 8

8x

POSSIBILITIES OF D110V PNEUMATIC LIFTER

USB / RS232C

SW1

OUTPUT

S_View D200SMultiplexer unit

134

MAX. 8 MAX. 8MAX. 8

8x8x8x

P2...P50 P2...P50P2...P50

POSSIBILITIES OF CONNECTION

S_View D200SMultiplexer unit

135

D302 / D302a

804.1210925.5609

DESCRIPTION

Multiplexer unit

804.1302 804.1303

D302 D302a

95 x 88 x 55

0.3

136

1

2

3

4

5

6

7

8

10

11

12

13

9

1

2

3

4

5

6

7

8

9

10

11

12

13

D302 / D302a Multiplexer unit

LED Power

LEDS channel

LED RS 485 activity

Port USB de connexion PC

RS 485 output

Ground connector

RS 485 input

External connector

Standard clamping (DIN 35mm)

Jumpers

Analogic output / 24 VDC

Porbes input

9V power supply input

Modele

Max error µm

Max. Error 1) µm

Repeatability µm

Overall dimension mm

Weight kg

Case

Protection rating according to IEC 60529

S_Connect

Programmable by PC

Analog output signal

P2 : 1.5 / P5 : 1.6 / P10 : 1.6 / P25 : 1.9 / P50 : 3.9

P2 : 0.5 / P5 : 0.6 / P10 : 0.6 / P25 : 0.8 / P50 : 1.5

P2 : 0.2 / P5 : 0.2 / P10 : 0.2 / P25 : 0.2 / P50 : 0.4

Aluminium profil / plastic TA 6

IP40

USB / RS 485

TECHNICAL SPECIFICATIONS

BASIC INSTRUMENT

HARDWARE DESCRIPTION

Unit according to technical specifications

Feet (pair)

RS232/RS485 cable

Charging unit according to country (904.4000)

Instruction manual

904.1108

904.1112

904.4000

904.4001

904.4002

904.4003

804.4000

904.4001

904.4002

904.4003

904.4101

904.6001

804.6001

804.1211

804.1073

804.1074

137

D200SD50S D60S D80SD100S

Ø8

0 -9

50

50

50

12

804.1074

60

Ø8

-5 -20

max

i.39

24

9

M3

D300S D302D304

ACCESSORIES

Display units

D108-additional 8 input unit for

probes

D110V-control unit with 16 vacuum

outputs

Charging set 100-240V / 9V

EUR cable included in 904.4000

UK cable included in 904.4000

USA/JPN cable included in 904.4000

Charging set 100-240V / 24V

EUR cable included in 804.4000

UK cable included in 804.4000

USA/JPN cable included in 804.4000

External contact (footpedal)

Dust cover

Dust cover

Connection cable D200S - D110/V

Table stand for D60S analog

display 804.1071 and 804.1072

Arm to fix D60S analog display

on PS17 bench

138