mastersealaw b 900 liquid flashing membrane - basf documents...maste uilder olution asf 36 air water...

15
Master Builders Solutions by BASF www.master-builders-solutions.basf.us 36 Air Water Barriers MasterSeal ® AWB 900 Liquid Flashing Membrane Typical Details for Framed and Masonry/Concrete Construction Incorporating MasterSeal AWB 900 Liquid Flashing Membrane TABLE OF CONTENTS 2. Typical Joint and Fastener Treatment 3. Typical Rough Opening Treatment with MasterSeal AWB 900 on Masonry Construction without Buck 4. Typical Rough Opening Treatment with MasterSeal AWB 900 on Framed Construction without Buck 5. Typical Rough Opening Treatment with MasterSeal AWB 900 on Masonry Construction with Flushed Buck 6. Typical Rough Opening Treatment with MasterSeal AWB 900 on Framed Construction with Flushed Buck 7. Typical Rough Opening Treatment with MasterSeal AWB 900 on Masonry Construction with a Recessed Buck 8. Typical Rough Opening Treatment with MasterSeal AWB 900 on Framed Construction with a Recessed Buck 9. Typical Rough Opening Treatment with MasterSeal AWB 900 on Masonry Construction with a Protruding Buck 10. Typical Rough Opening Treatment with MasterSeal AWB 900 on Framed Construction with a Protruding Buck 11. Typical Termination at Grade 12. Typical Pipe Penetration 13. Typical Sheathing Joint - Inside Corner 14. Typical Sheathing Joint - Outside Corner Technical Bulletin

Upload: voxuyen

Post on 09-Mar-2018

230 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: MasterSealAW B 900 Liquid Flashing Membrane - BASF Documents...Maste uilder olution ASF 36 Air Water Barriers MasterSeal®AW B 900 Liquid Flashing Membrane Typical Details for Framed

Master Builders Solutions by BASF www.master-builders-solutions.basf.us

36 Air WaterBarriers

MasterSeal® AWB 900 Liquid Flashing MembraneTypical Details for Framed and Masonry/ConcreteConstruction Incorporating MasterSeal AWB 900 Liquid Flashing Membrane

TABLE OF CONTENTS

2. Typical Joint and Fastener Treatment

3. Typical Rough Opening Treatment with MasterSeal AWB 900 on Masonry Construction without Buck

4. Typical Rough Opening Treatment with MasterSeal AWB 900 on Framed Construction without Buck

5. Typical Rough Opening Treatment with MasterSeal AWB 900 on Masonry Construction with Flushed Buck

6. Typical Rough Opening Treatment with MasterSeal AWB 900 on Framed Construction with Flushed Buck

7. Typical Rough Opening Treatment with MasterSeal AWB 900 on Masonry Construction with a Recessed Buck

8. Typical Rough Opening Treatment with MasterSeal AWB 900 on Framed Construction with a Recessed Buck

9. Typical Rough Opening Treatment with MasterSeal AWB 900 on Masonry Construction with a Protruding Buck

10. Typical Rough Opening Treatment with MasterSeal AWB 900 on Framed Construction with a Protruding Buck

11. Typical Termination at Grade

12. Typical Pipe Penetration

13. Typical Sheathing Joint - Inside Corner

14. Typical Sheathing Joint - Outside Corner

Technical Bulletin

Page 2: MasterSealAW B 900 Liquid Flashing Membrane - BASF Documents...Maste uilder olution ASF 36 Air Water Barriers MasterSeal®AW B 900 Liquid Flashing Membrane Typical Details for Framed

Technical BulletinTypical Details for Framed and Masonry/Concrete Construction Incorporating MasterSeal AWB 900 Liquid Flashing Membrane

Step One

Step Two

Step Three

Framing

• Ensure that MasterSeal AWB 900 is applied at a 20 mil thickness.

• Extend MasterSeal AWB 900 at least 25 mm (1”) on either side of sheathing joints.

• Allow MasterSeal AWB 900 to skin before applying fluid-applied air/water resistive barrier.

MasterSeal AWB 900 Liquid Flashing Membrane TYPICAL JOINT AND FASTENER TREATMENT

Acceptable Sheathing*

MasterSeal AWB 900

Spot Fasteners with MasterSeal AWB 900 or BASF Air/Water-Resistive Barrier

Spot Fasteners with MasterSeal AWB 900 or MasterSeal AWB

Spot Fasteners with MasterSeal AWB 900 or MasterSeal AWB

Framing*

Acceptable Sheathing*

MasterSeal AWB 900Spread Evenly

Framing*

Acceptable Sheathing*

MasterSeal AWB 900 Spread Evenly

MasterSeal AWB 660 or MasterSeal AWB 665 or MasterSeal AWB 660 I

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 2 of 15

Page 3: MasterSealAW B 900 Liquid Flashing Membrane - BASF Documents...Maste uilder olution ASF 36 Air Water Barriers MasterSeal®AW B 900 Liquid Flashing Membrane Typical Details for Framed

Technical BulletinTypical Details for Framed and Masonry/Concrete Construction Incorporating MasterSeal AWB 900 Liquid Flashing Membrane

Step One Step Two

Step ThreeStep Four

Concrete / MasonryMasterSeal AWB 900

• Ensure that MasterSeal AWB 900 is uniformly applied at a 12-20 mil thickness.

• Extend MasterSeal AWB 900 at least 100 mm (4”) onto the exterior wall, maintaining 12-20 mil thickness.

• Allow MasterSeal AWB 900 to skin before applying fluid-applied air/ water resistive barrier.

• Lap air/water-resistive barrier at least 50 mm (2”) onto MasterSeal AWB 900, creating a continuous, monolithic air/ water resistive barrier

MasterSeal AWB 900 Liquid Flashing Membrane TYPICAL ROUGH OPENING TREATMENT WITH MAXFLASHON MASONRY OR CONCRETE CONSTRUCTION WITHOUT BUCK

MasterSeal AWB 900Spread Evenly Across the Rough Opening

MasterSeal AWB 900

MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 3 of 15

Page 4: MasterSealAW B 900 Liquid Flashing Membrane - BASF Documents...Maste uilder olution ASF 36 Air Water Barriers MasterSeal®AW B 900 Liquid Flashing Membrane Typical Details for Framed

Technical BulletinTypical Details for Framed and Masonry/Concrete Construction Incorporating MasterSeal AWB 900 Liquid Flashing Membrane

Step One Step Two

Step Three Step Four

• Ensure that MasterSeal AWB 900 is uniformly applied at a 12-20 mil thickness.

• Extend MasterSeal AWB 900 at least 100 mm (4”) onto the exterior wall, maintaining 12-20 mil thickness.

• Allow MasterSeal AWB 900 to skin before applying fluid-applied air/ water resistive barrier.

• Lap air/water-resistive barrier at least 50 mm (2”) onto MasterSeal AWB 900, creating a continuous, monolithic air/ water resistive barrier

MasterSeal AWB 900 Liquid Flashing Membrane TYPICAL ROUGH OPENING TREATMENT WITH MASTERSEAL AWB 900ON FRAMED CONSTRUCTION WITHOUT BUCK

Framing

Acceptable Sheathing*MasterSeal AWB 900

MasterSeal AWB 900

MasterSeal AWB 900Spread Evenly Across the Rough Opening

MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 4 of 15

Page 5: MasterSealAW B 900 Liquid Flashing Membrane - BASF Documents...Maste uilder olution ASF 36 Air Water Barriers MasterSeal®AW B 900 Liquid Flashing Membrane Typical Details for Framed

Technical BulletinTypical Details for Framed and Masonry/Concrete Construction Incorporating MasterSeal AWB 900 Liquid Flashing Membrane

Step One Step Two

Step Three Step Four

MasterSeal AWB 900 Liquid Flashing Membrane TYPICAL JOINT AND FASTENER TREATMENT

MasterSeal AWB 900Spread Evenly Across the Rough Opening

Concrete / Masonry

Flush Wood Buck*

MasterSeal AWB 900

MasterSeal AWB 900

• Ensure that MasterSeal AWB 900 is uniformly applied at a 12-20 mil thickness.

• Extend MasterSeal AWB 900 at least 100 mm (4”) onto the exterior wall, maintaining 12-20 mil thickness.

• Allow MasterSeal AWB 900 to skin before applying fluid-applied air/ water resistive barrier.

• Lap air/water-resistive barrier at least 50 mm (2”) onto MasterSeal AWB 900, creating a continuous, monolithic air/ water resistive barrier

MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 5 of 15

Page 6: MasterSealAW B 900 Liquid Flashing Membrane - BASF Documents...Maste uilder olution ASF 36 Air Water Barriers MasterSeal®AW B 900 Liquid Flashing Membrane Typical Details for Framed

Technical BulletinTypical Details for Framed and Masonry/Concrete Construction Incorporating MasterSeal AWB 900 Liquid Flashing Membrane

Step One Step Two

Step ThreeStep Four

MasterSeal AWB 900 Liquid Flashing Membrane TYPICAL ROUGH OPENING TREATMENT WITH MASTERSEAL AWB 900ON FRAMED CONSTRUCTION WITH FLUSH BUCK

MasterSeal AWB 900Spread Evenly Across the Rough Opening

Framing*

Acceptable Sheathing*

MasterSeal AWB 900

MasterSeal AWB 900

Flush Wood Buck*

• Ensure that MasterSeal AWB 900 is uniformly applied at a 12-20 mil thickness.

• Extend MasterSeal AWB 900 at least 100 mm (4”) onto the exterior wall, maintaining 12-20 mil thickness.

• Allow MasterSeal AWB 900 to skin before applying fluid-applied air/ water resistive barrier.

• Lap air/water-resistive barrier at least 50 mm (2”) onto MasterSeal AWB 900, creating a continuous, monolithic air/ water resistive barrier

MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 6 of 15

Page 7: MasterSealAW B 900 Liquid Flashing Membrane - BASF Documents...Maste uilder olution ASF 36 Air Water Barriers MasterSeal®AW B 900 Liquid Flashing Membrane Typical Details for Framed

Technical BulletinTypical Details for Framed and Masonry/Concrete Construction Incorporating MasterSeal AWB 900 Liquid Flashing Membrane

Step One Step Two

Step Three Step Four

MasterSeal AWB 900 Liquid Flashing Membrane TYPICAL ROUGH OPENING TREATMENT WITH MASTERSEAL AWB 900 ONMASONRY OR CONCRETE CONSTRUCTION WITH A RECESSED BUCK

Concrete / Masonry*

Recessed Wood Buck*

MasterSeal AWB 900

MasterSeal AWB 900

MasterSeal AWB 900

• Ensure that MasterSeal AWB 900 is uniformly applied at a 12-20 mil thickness.

• Extend MasterSeal AWB 900 at least 100 mm (4”) onto the exterior wall, maintaining 12-20 mil thickness.

• Allow MasterSeal AWB 900 to skin before applying fluid-applied air/ water resistive barrier.

• Lap air/water-resistive barrier at least 50 mm (2”) onto MasterSeal AWB 900, creating a continuous, monolithic air/ water resistive barrier

MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 7 of 15

Page 8: MasterSealAW B 900 Liquid Flashing Membrane - BASF Documents...Maste uilder olution ASF 36 Air Water Barriers MasterSeal®AW B 900 Liquid Flashing Membrane Typical Details for Framed

Technical BulletinTypical Details for Framed and Masonry/Concrete Construction Incorporating MasterSeal AWB 900 Liquid Flashing Membrane

Step One Step Two

Step Three Step Four

MasterSeal AWB 900 Liquid Flashing Membrane TYPICAL ROUGH OPENING TREATMENT WITH MASTERSEAL AWB 900ON FRAMED CONSTRUCTION WITH A RECESSED BUCK

MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

MasterSeal AWB 900Spread Evenly Across the Rough Opening

Framing*

Acceptable Sheathing*

Recessed Wood Buck*

MasterSeal AWB 900

MasterSeal AWB 900

• Ensure that MasterSeal AWB 900 is uniformly applied at a 12-20 mil thickness.

• Extend MasterSeal AWB 900 at least 100 mm (4”) onto the exterior wall, maintaining 12-20 mil thickness.

• Allow MasterSeal AWB 900 to skin before applying fluid-applied air/ water resistive barrier.

• Lap air/water-resistive barrier at least 50 mm (2”) onto MasterSeal AWB 900, creating a continuous, monolithic air/ water resistive barrier

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 8 of 15

Page 9: MasterSealAW B 900 Liquid Flashing Membrane - BASF Documents...Maste uilder olution ASF 36 Air Water Barriers MasterSeal®AW B 900 Liquid Flashing Membrane Typical Details for Framed

Technical BulletinTypical Details for Framed and Masonry/Concrete Construction Incorporating MasterSeal AWB 900 Liquid Flashing Membrane

Step One Step Two

Step Three Step Four

MasterSeal AWB 900 Liquid Flashing Membrane TYPICAL ROUGH OPENING TREATMENT WITH MASTERSEAL AWB 900 ONMASONRY OR CONCRETE CONSTRUCTION WITH A PROTRUDING BUCK

MasterSeal AWB 900Spread Evenly Across the Rough Opening

Protruding Wood Buck*

• Ensure that MasterSeal AWB 900 is uniformly applied at a 12-20 mil thickness.

• Extend MasterSeal AWB 900 at least 100 mm (4”) onto the exterior wall, maintaining 12-20 mil thickness.

• Allow MasterSeal AWB 900 to skin before applying fluid-applied air/ water resistive barrier.

• Lap air/water-resistive barrier at least 50 mm (2”) onto MasterSeal AWB 900, creating a continuous, monolithic air/ water resistive barrier

Concrete / Masonry*

MasterSeal AWB 900

MasterSeal AWB 900

MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 9 of 15

Page 10: MasterSealAW B 900 Liquid Flashing Membrane - BASF Documents...Maste uilder olution ASF 36 Air Water Barriers MasterSeal®AW B 900 Liquid Flashing Membrane Typical Details for Framed

Technical BulletinTypical Details for Framed and Masonry/Concrete Construction Incorporating MasterSeal AWB 900 Liquid Flashing Membrane

Step OneStep Two

Step Three Step Four

MasterSeal AWB 900 Liquid Flashing Membrane TYPICAL ROUGH OPENING TREATMENT WITH MASTERSEAL AWB 900ON FRAMED CONSTRUCTION WITH A PROTRUDING BUCK

MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

MasterSeal AWB 900Spread Evenly Across the Rough Opening

Framing*

Acceptable Sheathing*

Protruding Wood Buck*

MasterSeal AWB 900

MasterSeal AWB 900

• Ensure that MasterSeal AWB 900 is uniformly applied at a 12-20 mil thickness.

• Extend MasterSeal AWB 900 at least 100 mm (4”) onto the exterior wall, maintaining 12-20 mil thickness.

• Allow MasterSeal AWB 900 to skin before applying fluid-applied air/ water resistive barrier.

• Lap air/water-resistive barrier at least 50 mm (2”) onto MasterSeal AWB 900, creating a continuous, monolithic air/ water resistive barrier

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 10 of 15

Page 11: MasterSealAW B 900 Liquid Flashing Membrane - BASF Documents...Maste uilder olution ASF 36 Air Water Barriers MasterSeal®AW B 900 Liquid Flashing Membrane Typical Details for Framed

Technical BulletinTypical Details for Framed and Masonry/Concrete Construction Incorporating MasterSeal AWB 900 Liquid Flashing Membrane

Step One

Step Two

Step Three

MasterSeal AWB 900 Liquid Flashing Membrane TYPICAL TERMINATION AT GRADE

MasterSeal AWB 660 or MasterSeal AWB 665 or MasterSeal AWB 660 I

Framing*

Framing*

Framing*

Foundation*

Foundation*

Foundation*

Acceptable Sheathing*

Acceptable Sheathing*

Acceptable Sheathing*

MasterSeal AWB 900

MasterSeal AWB 900

MasterSeal AWB 900

• Ensure that MasterSeal AWB 900 is applied at a 20 mil thickness.

• Extend MasterSeal AWB 900 at least 25 mm (1”) on either side of foundation joints.

• Allow MasterSeal AWB 900 to skin before applying fluid-applied air/water resistive barrier.

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 11 of 15

Page 12: MasterSealAW B 900 Liquid Flashing Membrane - BASF Documents...Maste uilder olution ASF 36 Air Water Barriers MasterSeal®AW B 900 Liquid Flashing Membrane Typical Details for Framed

Technical BulletinTypical Details for Framed and Masonry/Concrete Construction Incorporating MasterSeal AWB 900 Liquid Flashing Membrane

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 12 of 15

• Maximum 1/2” gap at penetrations.

MasterSeal AWB 900 Liquid Flashing Membrane TYPICAL PIPE PENETRATION

MasterSeal AWB 660 or MasterSeal AWB 665 or MasterSeal AWB 660 I

Pipe*

Framing*

Acceptable Sheathing*

MasterSeal AWB 900

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 12 of 15

Page 13: MasterSealAW B 900 Liquid Flashing Membrane - BASF Documents...Maste uilder olution ASF 36 Air Water Barriers MasterSeal®AW B 900 Liquid Flashing Membrane Typical Details for Framed

Technical BulletinTypical Details for Framed and Masonry/Concrete Construction Incorporating MasterSeal AWB 900 Liquid Flashing Membrane

Step One

Step Two

Step Three

MasterSeal AWB 900 Liquid Flashing Membrane TYPICAL SHEATHING JOINT - INSIDE CORNER

MasterSeal AWB 660 or MasterSeal AWB 665 or MasterSeal AWB 660 I

Framing*

Framing*

Framing*

Acceptable Sheathing*

Acceptable Sheathing*

Acceptable Sheathing*

MasterSeal AWB 900

MasterSeal AWB 900

• Ensure that MasterSeal AWB 900 is applied at a 20 mil thickness.

• Extend MasterSeal AWB 900 at least 25 mm (1”) on either side of foundation joints.

• Allow MasterSeal AWB 900 to skin before applying fluid-applied air/water resistive barrier.

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 13 of 15

Page 14: MasterSealAW B 900 Liquid Flashing Membrane - BASF Documents...Maste uilder olution ASF 36 Air Water Barriers MasterSeal®AW B 900 Liquid Flashing Membrane Typical Details for Framed

Technical BulletinTypical Details for Framed and Masonry/Concrete Construction Incorporating MasterSeal AWB 900 Liquid Flashing Membrane

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 14 of 15

Step One

Step Two

Step Three

MasterSeal AWB 900 Liquid Flashing Membrane TYPICAL SHEATHING JOINT - OUTSIDE CORNER

• Ensure that MasterSeal AWB 900 is applied at a 20 mil thickness.

• Extend MasterSeal AWB 900 at least 25 mm (1”) on either side of foundation joints.

• Allow MasterSeal AWB 900 to skin before applying fluid-applied air/water resistive barrier.

MasterSeal AWB 660 or MasterSeal AWB 665 or MasterSeal AWB 660 I

Framing*

Framing*

Framing*

Acceptable Sheathing*

Acceptable Sheathing*

Acceptable Sheathing*

MasterSeal AWB 900

MasterSeal AWB 900

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 14 of 15

Page 15: MasterSealAW B 900 Liquid Flashing Membrane - BASF Documents...Maste uilder olution ASF 36 Air Water Barriers MasterSeal®AW B 900 Liquid Flashing Membrane Typical Details for Framed

BASF Corporation 889 Valley Park Drive, Shakopee, MN 55379 Customer Service 1(800) 433.9517 Construction Systems www.master-builders-solutions.basf.us Technical Service 1(800) 243.6739

Technical BulletinTypical Details for Framed and Masonry/Concrete Construction Incorporating MasterSeal AWB 900 Liquid Flashing Membrane

® = Registered trademark of the BASF-Group in many countries.© 2016 BASF Corporation | Construction Systems | Part no. 14000256 rev 12/16

HEALTH , SAFETY AND ENVIRONMENTAL Read, understand and follow all Safety Data Sheets and product label information for this product prior to use. The SDS can be obtained by visiting www.master-builders-solutions.basf.us, e-mailing your request to [email protected] or calling 1(800) 433-9517. Use only as directed. For medical emer-gencies only, call ChemTrec® 1(800)424-9300.

LIMITED WARRANTY NOTICE BASF warrants this product to be free from manu-facturing defects and to meet the technical proper-ties on the current Technical Data Guide, if used as directed within shelf life. Satisfactory results depend not only on quality products but also upon many factors beyond our control. BASF MAKES NO OTHER WARRANTY OR GUARANTEE, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MER-CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ITS PRODUCTS. The sole and exclusive remedy of Purchaser for any claim concerning this product, including but not limited to, claims alleging breach of warranty, negligence, strict liability or otherwise, is the replacement of product or refund of the purchase price, at the sole option of BASF. Any claims concerning this product must be received in writing within one (1) year from the date of shipment and any claims not presented within that period are waived by Purchaser. BASF WILL NOT BE RESPONSIBLE FOR ANY SPECIAL, INCIDENTAL, CONSEQUENTIAL (INCLUDING LOST PROFITS) OR PUNITIVE DAMAGES OF ANY KIND.

Purchaser must determine the suitability of the prod-ucts for the intended use and assumes all risks and liabilities in connection therewith. This information and all further technical advice are based on BASF’s present knowledge and experience. However, BASF assumes no liability for providing such information and advice including the extent to which such infor-mation and advice may relate to existing third party intellectual property rights, especially patent rights, nor shall any legal relationship be created by or arise from the provision of such information and advice. BASF reserves the right to make any changes ac-cording to technological progress or further develop-ments. The Purchaser of the Product(s) must test the product(s) for suitability for the intend-ed application and purpose before proceeding with a full application of the product(s). Performance of the product described herein should be verified by testing and carried out by qualified experts.