[email protected] cas on magnets · 2017-06-23 · longitudinal . gyromagnetic . component....

59
Field Measurement Methods [email protected] CAS on Magnets Novotel Brugge Centrum, Bruges, Belgium 16 - 25 June, 2009

Upload: others

Post on 06-Apr-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Field Measurement [email protected]

CAS on Magnets

Novotel Brugge Centrum, Bruges, Belgium16 -

25 June, 2009

Page 2: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Overview

NMR/EPR, the golden standardFluxmeters, the workhorse for accelerators

fixed, moving, flipping, rotating coils and wiresHall generators and magneto-resistors, cheapOther fun methods

Fluxgate magnetometers, sensitiveSQUIDS, quantum sensitiveAtomic and SERF magnetometers, yet more sensitiveFaraday rotation, fast

Concluding remarks, and a design graph

Page 3: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

NMR/EPR principlea particle with a spin and magnetic moment in an applied field precesses at a (Larmor) frequency f:

f = γ B

applied magnetic field

precession

spin magnetic moment

rotating component

longitudinal componentgyromagnetic

ratio

Page 4: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Gyromagnetic ratio

particle γ (MHz/T)

e- 28.025 x 103

1H 42.576396(3)2H 6.535 2He 32.4326 13C 10.71 14N 3.08 19F 40.08 23Na 11.27 27Al 11.093 31P 17.25

1 GHz NMR

magnet ⇓

23.5 T

Electron Paramagnetic Resonance (EPR),

Electron Spin Resonance (ESR)

Nuclear Magnetic Resonance (NMR)

cryogenic probes

Page 5: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Resonance and coherence

a transverse RF pulse of frequency f induces resonance in the precession and coherence in Mt

RF pulse

coherence decay

Page 6: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Bloch, Purcell, 1946

500 mm3

sample

receiver

transmitter

Phys. Rev., 70, 460, 1946

Rabi, 1938

Page 7: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

+

VNMR

probe

B0

RF

B

Osc.

S/H

∫ VCO

trigger

field modulation

frequency error signal

A DIY NMR magnetometer

0.1 ppm absolute accuracy achievable (0.1 Hz)

Page 8: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Field tracking

tracking is slow (Hz): maximum field variation tolerated for latching δB/B < 1 % s-1

field gradients blur signal: field homogeneity ∇B/B < 10 … 100 ppm/mm

gradient coils to measure inhomogeneous fields !

NMR signal

field modulation

error voltage

Page 9: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Free Induction DecayMt decay after RF pulse (FID)

high accuracy for long measurement timesmain tool for spectroscopy

analysis of chemicals, moleculesstructure determination (COSY, NOSY, …)

T2

*

Page 10: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

ImagingMagnetic Resonance Imaging (MRI)

P. Lauterbur, 1973

z

B

f = γ B

z

fδf

δz courtesy of Philips

2000 Ig Nobel Prize winner, Annals of Improbable Researchl.W. Schultz, P. van Andel, I. Sabelis, E. MooyaartMagnetic resonance imaging of male and female genitals during coitus and female sexual arousalBritish Medical Journal, 319, 1596-1600, 1999.

Page 11: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Γ

S

B∫=S

dSBϕ

dtdV ϕ

−=

∫−=−end

start

t

tstartend dtVϕϕ

FluxmeterMagnetic flux:

Induction law:

κϕϕ startend

startend BB −=−

needs an integrator…

and coil calibration

Page 12: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Ann. Der Physik, 2, 209, 1853

magnetic inclination in Göttingen, also measured by:- Gauss- Humboldt- Forbes

that the determination of the inclination through the evaluation of the induction with the magnetometer are not worse

than the results obtained so far with the best inclinometers;

Inductions-Inclinatorium

few arcmin change observed over 50 years

… daß die durch Vermittlung der Induction mit dem Magnetometer an Präcision auch den durch die sorgfältigsten Beobachtungen mit den besten bisherigen Inclinatorien gewonnenen Resultaten nicht nachstehen;

Page 13: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Analog integrator (Miller)

R−

+

C

Vin

Vout

Rcoil

Rdischarge

∫∞−

−=t

inout dtVRC

V 1

shielding and control:-

leakage current-

ground current-

temperature coefficient-

dielectric absorption

triggering

simple, inexpensive, effectiveaccuracy limited by analog electronics

R+Rcoil

Page 14: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Digital integrator

+

Vin

Vref

Rcoil

VFCCNT 1

CNT 2μP

fref

n

∫∫ ==end

start

end

start

t

tinVFC

t

t

dtVKfdtn

digital output, no cumulative error, 10…100 ppm accuracy !VFC linearity and stability, counter resolution (Δt/(4 fref

) ppm)

voltage offset

parallel counters

instrumentation amplifier (Zinput

) Voltage to Frequency Converter

-Vref

…+Vref 0…2Vref 0…fref

Page 15: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Numerical integrator

Vin Rcoil

DVM

t

V

Vi

Δtitrigger

Vi

ti

Vi-1

ti ti-1

digital output, powerful numerical integration possibleprecise time required, dead-times, may need 2 DVM’s

digital approximation for numerical integration

Page 16: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Fast Digital Integrator

faster integrals (100 kHz), improved resolution (1 ppm)

+

Vin Rcoil

fref

ADC

FPGA

DSP

CLCK

C-PCI/PXI BUS -Vmax

…+Vmax 0…2Nbit

instrumentation amplifier (Zinput

)

Analog to Digital Converter

Field Programmable Gate Array

Digital Signal Processor

Page 17: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Point coils –

the Fluxball

winding axis

winding core

radius

winding density

W.F. Brown, J.H. Sweer,Rev. Sci. Instr., 16, 276, 1945

measure average field in a small volume (point-like)can be approximated by co-axial solenoids of proper R/H

Page 18: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Line and area coils

250

2250

0.5

Courtesy of J. Billan, CERN

integrated field over long lengthsrelevant for accelerators

Page 19: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Harmonic coils

+

+

+

+

− −

dBz/dx

dBz/dz

Morgan coil (B4

)Gradient coils

measure field gradients or higher order terms (bucking)high resolution through compensation of background field signal

G.M. Morgan, Proc. MT-4, 787-790, 1972

Page 20: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Fluxmeter zooFixed coil measurements

Static coils (dS/dt=0), the field change (dB/dt) induces the voltageProvides only a relative measurement (Bend-Bstart)The voltage offsets cannot be distinguished from physical signal

Γ

S

B

00123

dtdV ϕ

−= ∫=S

dSBϕ

Moving coil measurementsSteady field (dB/dt=0), the coil movement (dS/dt) induces the voltageRequires well controlled mechanics, simple movementsProvides and absolute measurement if:

initial Bstart=0 moving from far away into the magnet (zero-gauss chamber): moving coilusing symmetries Bend=-Bstart: flip coil, rotating coil

A voltage offsets can be distinguished from physical signal

Most flexible method in all its many variants, although…

“…This type of magnetometer is obsolete.”

http://en.wikipedia.org/wiki/Magnetometer

Page 21: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

A rotating coil ???

no, actually this is a fixed coil with 800 turns and ≈

250 m2

surface that has been used to verify e.m. coupling of LEP and SPS

26”

Record wheel

Page 22: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Rotating snakes @ CERN

16 m

36

0.1 μT, 0.05 mrad resolution, 100 ppm accuracy

Page 23: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Complex formalismSC magnets for accelerators

2-D field (slender magnet), with components only in x and y and no component along zIgnore z and define the complex plane s = x + i y

Complex field function:

B is analytic in s and can be expanded in Taylor series (the series converges) inside a current-free disk:

xy iBB +=B

1

1

−∞

=∑ ⎟

⎟⎠

⎞⎜⎜⎝

⎛=+

n

n refnxy R

iBB sC nnn iAB +=C

Page 24: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Multipolescomplex multipole coefficients:

nnn iAB +=C

B1

≠0, normal dipole

A1

≠0, skew dipole

n=1 n=2

A2

≠0, skew quadrupole

B2

≠0, normal quadrupolen=3

1

1

−∞

=∑ ⎟

⎟⎠

⎞⎜⎜⎝

⎛=+

n

n refnxy R

iBB sC

Page 25: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Rotating coil in normal dipole

maxima and minima located at 0 and πcos(θ) waveform

Page 26: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Rotating coil in skew dipole

maxima and minima located at π/2 and 3/2 πflux de-phased by –π/2

with respect to normal dipole

sin(θ)

waveform

Page 27: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Rotating in normal quadrupole

maxima and minima located at 0, π/2, π

and 3/2 πflux variation twice faster than in a dipolecos(2 θ)

waveform

Page 28: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Rotating in skew quadrupole

maxima and minima located at 1/4 π, 3/4 π, 5/4 π

and 7/4 πflux de-phased by –π/4

with respect to normal quadrupole

sin(2 θ)

waveform

Page 29: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Rotating in normal sextupole

cos(3 θ)

waveform …

Page 30: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Fourier analysisn=2, B2

≠0

1 2 3-3 -2 -1

Ψn

n

n=1, A1

≠0

1 2 3-3 -2 -1

Ψn

n

n=1, B1

≠0

1 2 3-3 -2 -1

Ψn

n

Fourier transformed flux

coil calibration

and so on…

…by induction: Cn =˜ ϕ nκn

Page 31: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

I

v

F

B

B cos( )

VH

+ + +

+ + + +

Hall generator principlethin slab of semiconducting material (AIIIBV):- InAs- InSb- GaAs

DC current

Lorentz force F = v x Btransverse DC

(Hall) voltage

Page 32: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Amer. J. Math., 2, 287, 1879

iron foil

voltage tap

magnet

current lead

SOMETIME

during the last University year…

Page 33: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Hall coefficientHall voltage:

RH(B): material dependent Hall coefficienthigh mobility, low conductivity to have high RH

metals (low mobility)alloys (high resistivity causes heating)compromise choice: semiconductors

temperature dependence 100 to 1000 ppm/ºCG (B): geometry factor

equipotential lines deform under v x BOptimal design to compensate RH vs G

Cruciform design achieves 1 % linearity over wide B rangebetter definition of magnetic center

( )θcosIBGRV HH =

100 ppm accuracy feasible

Page 34: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Hall magnetometera Hall sensor is a 4-terminals device

do NOT connect outputs in series !!!

DC measurement can resolve 1…10 μTAC (lock-in) can resolve 0.1 μT

I= I0 sin(2πft), f = 10 Hz … 1 kHz

VHall DVM

I

DVM

+ VHall

Vout

DVM

I

+

Vout

DVM

Page 35: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

magnetic field

ΔRH/R

H

Quantum Hall effectShubnikov-de Haas effect

oscillation in RH periodic function of 1/B

periodic oscillation of ΔRH

/RH

effect as much as 1 % on calibration coefficient

B > 2 T

4.2 K

Page 36: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Planar Hall effect( )ϕ2cos2BVV HPplanar =

Vplanar

is important when mapping 3-D fields

BI φ

Vplanar

Page 37: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Phil. Trans.,146, 736, 1856

B

ΔR/R

0

Page 38: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Magnetoresistors

B

I

VB

InSb slab

NiSb precipitates

two-terminal device, simple, inexpensivemodest sensitivity, non-linear, T effects (2500 ppm/ºC)bias field, compensated bridges, giant-magnetoresistance

Page 39: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Fluxgate (Peaking Strip)

B

excitation coil

bias coil

detection coil

+Bexcitation

-Bexcitation

J. M. Kelly, Magnetic Field Measurements with Peaking Strips, Rev. Sci. Inst., 22, 256, 1930

Page 40: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

M

H

t

H

M

t

M1, M2

M1-M2

V

t

Fluxgate principle -

1

B

excitation coil

bias coil

detection coil

Page 41: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Fluxgate principle -

2

B

excitation coil

bias coil

detection coil

M

H

t

HH0

V

t

M

t

M1

M1-M2

M2

Page 42: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Fluxgate applicationssimple and inexpensive, lightweight devicehighly directionalhigh sensitivity (tens of pT !)modest accuracy (1000 ppm)typical applications

navigationgeology, ores, oil fieldshunting submarinesfinding minesmapping of interplanetary magnetic field

Page 43: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

A special fluxgate: the DCCT

excitation coil

bias coil

detection coil

B

I

best known device for high current (relevant for SC magnets)1 ppm possible at 10 kA (10 mA)

Page 44: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

SQUID principles –

1

change δ of phase of wave-function for paired electrons along Γ depends on magnetic flux ϕ:

flux quantization: δ = 2π n0

2ϕϕπδ =

path Γ

around a normal conducting region

superconductor

quantum fluxoid (2 x 10-15

Wb)

0ϕϕ n=

A. Abrikosov

Page 45: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

the wave-function can tunnel through a normal-conducting (Josephson) junction the maximum supercurrent depends on δ:

SQUID principles –

2

( )δsincII =

superconductor

normal conductorδ

superconductorB. Josephson

Page 46: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

V

Ibias

δ1,I1B

δ2,I2

The SQUIDmaximum supercurrent:

phase relation:

SQUID critical current

⎟⎟⎠

⎞⎜⎜⎝

⎛=

0

cos2ϕϕπcII

021 2

ϕϕπδδδ =−+

( ) ( )[ ]21 sinsin δδ += cII

Josephson junction

SC ring

Page 47: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

SQUID operationSQUID voltage periodic in ϕ0

flux change Δϕ from ΔV, compute ΔB using κbias current

sensitivity few pT for bare SQUID, 1 fT with input transformerrange limited by FB, accuracy limited by calibration of surface

V

Ibias

δ1,I1B

δ2,I2

Page 48: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

SQUID Magnetometry

151 SQUID channelshelmet

magnetoencefalogram

cortical activation of the primary and secondary somatosensory cortex during left median nerve simulation measured by MEG and fMRI…

HTS

LTS

Page 49: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

The frontier of magnetometry

Alkali atoms (Rb, Cs) have unpaired electrons whose spin precesses with magnetic field (as protons)The interaction with field can be detected as follows:

An alkali metal vapor is prepared in a cellA first laser (the pump) aligns the spins to create coherence (as the RF pulse in NMR techniques)A second laser (the probe) detects resonance, which can be seen, e.g., as a shift in an interference pattern

Excellent device for miniaturizationSandia National Laboratories

Page 50: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

A digression on spectra

The gross structure of the spectral line of atoms (energy level), are split in:

A fine structure (due to interaction of magnetic moment of electron spin and orbital angular momentum)

A hyperfinestructure, due to interaction of nucleus magnetic moment with internal magnetic/electric fields in the atom

E

794 nm377 THz

52P1/2

52S1/287

Rb

D1

line

6.83 GHz

The hyperfine structure further

splits in a magnetic field (Zeeman effect) proportionally to B

F=2

F=1

m=2m=1m=0m=-1m=-2

hΔν

μgB

P. Zeeman

finehyperfine

Zeeman

Page 51: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Atomic magnetometer DIY

Set a laser on a given absorption line (e.g. D1 of 87Rb, 794 nm)AM the laser with a VCO to create two sidebands corresponding to the hyperfine structure (central f = 3.42 GHz)Modulate the VCO (by ± 3 MHz) to detect the resonances from the split hyperfine levelsCompute the difference of frequency between two resonances, which is proportional to the magnetic field:

hΔν

μgBNIST

Princeton University

sensitivity in the range of tens of fTrange limited to 1 mT at most, accuracy not established so far

Page 52: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

SERF atomic magnetometersSpin Exchange collisions preserve total momentum but cause single spins to change, scrambling the hyperfine structureThe precession of atoms in the vapor loses quickly coherence, the resolution of the resonance is limited

At low B and high gas density, collisions happen quicker than the precession time of the atoms. On average the hyperfine states are stable, the Spin Exchange is Relaxation FreeThe resonance is measured with improved resolution !

J.C. Allred, R.N Lyman, T.W. Kornack, M.V. Romalis, High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation, Phys Rev Lett 89, 130801, 2002

Page 53: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Premium sensitivity !Best quoted sensitivity is 200 aT/√Hz !

0.2 x 10-15 T at 1 Hz

A new world of possibilities

Magnetoencelography,Magnetocardiography of in fetal hearts,Earth field NMR …

a Tricorder ?!?

Example: NMR signal from water on chip

Page 54: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

850 T pulsed field at LANL

material properties at high magnetic

fields (8 to 10 MG)

a shot …

imploding flux compression generator (VNIIEF design)

Page 55: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

850 T shot at LANL

experimenttime

implosion and

flux compression

sample destroyed

how do you measure this ???

Page 56: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Faraday effect

material v (rad / T m)

fused quartz 4

flint glass 110

benzene 9

rotation angle

Verdet constant

field strength

lengthLBv=θ

rotation of light polarization in a media in a magnetic field

detector

laser

polarizer

sample

analizermagnet

fast, e.m. compatible at high electric fieldsmodest accuracy (1 %)

Page 57: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Field imaginglight polarization can be used to image the field:

Faraday rotationferrofluid cell

direct magnetic center measurement (image treatment)needs higher field than e.m. methods, limited accuracy

center of a RHIC quadrupole at 75 T/m gradient during cold testing

Courtesy of A. Jain,BNL

Page 58: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Performance summary

Page 59: Luca.Bottura@cern.ch CAS on Magnets · 2017-06-23 · longitudinal . gyromagnetic . component. ratio. Gyromagnetic ratio particle γ (MHz/T) e - 28.025 x 10 3 1 ... a transverse RF

Conclusionsthe art of magnetic measurements cannot be made into a science

at least I have given up…methods and instruments exist, don’t try to make them yourself, use them if you can

as for italian cuisine let Mom do it……or buy a good cooking book before you start

where can I find out more ?CAS on MM, MT, PAC, EPAC(NIM) uNclear Instruments and Methods