7 7 Description Soft copper conductor, XLPE insulated. Construction Conductor Compressed Stranded Soft copper. Insulation Cross Linked Polyethylene (XLPE 90°C). Options Aluminum Conductor, XLPE SR (Sunlight resistant) insulation. For sizes greater than 1/0 AWG, Type Tray Cable (TC). Characteristics Operating temperature Dry Locations: 90°C Wet Locations: 90°C Operating Voltage 600 V. Uses and Applications Overhead distribution of electric energy in low voltage systems. Connection to boards, motors, and building wiring. Installation ducts and raceways. Abrasion and moisture resistant insulation, its dimensions permits optimal filled in tubes and ducts. Pass VW-1 Vertical flame Test. XHHW-2 Cables Cross (X) Linked Polyethylene Insulation, High Heat resistant (90°C), 2: Suitable for Dry and Wet Locations

Upload: stephanie-sanchez

Post on 06-Mar-2016

238 views

Category:

Documents


1 download

DESCRIPTION

Low voltage cables

TRANSCRIPT

Page 1: Low voltage cables

77

Description

Soft copper conductor, XLPE insulated.

Construction

ConductorCompressed Stranded Soft copper.

InsulationCross Linked Polyethylene (XLPE 90°C).

OptionsAluminum Conductor, XLPE SR (Sunlight resistant) insulation.For sizes greater than 1/0 AWG, Type Tray Cable (TC).

Characteristics

Operating temperatureDry Locations: 90°CWet Locations: 90°C

Operating Voltage600 V.

Uses and Applications

Overhead distribution of electric energy in low voltage systems. Connectionto boards, motors, and building wiring.

Installation ducts and raceways. Abrasion and moisture resistant insulation,its dimensions permits optimal filled in tubes and ducts. Pass VW-1 Verticalflame Test.

XHHW-2 CablesCross (X) Linked Polyethylene Insulation, High Heat resistant (90°C),2: Suitable for Dry and Wet Locations

Page 2: Low voltage cables

8

Standards and Specifications

CENTELSA XHHW-2 cables are manufacturing according to thefollowing standards:

ASTM B3, NTC-ICONTEC 359. Soft copper wire.ASTM B8, NTC-ICONTEC 307. Concentric Lay Stranded copperconductors.ASTM B787. 19 Wire Combination Unilay Stranded Copper conductorsfor subsequent insulationUL 1581, NTC-3203. Reference Standard for Electrical Wires, Cablesand Flexible Cords.UL 44, NTC-3277. Thermo set-Insulated Wires and Cables.

Certifications

CENTELSA XHHW-2 Cables type, are certified by:UL 44 File E137698.

Note: Other configurations and sizes not specified herein are availableupon request.

Page 3: Low voltage cables

9

Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2. 90°C conductor temperature, 30°C ambient temperature, According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. One single conductor at free air at 30°C ambient temperature.4. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature.5. According to NEC NTC 2050 the minimun size for use in Tray Cables must be 1/0 AWG for phase conductors, and 4 AWG for grounding conductors.6. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

Cables Type XHHW-2 600V (International Unit System)Cross (X) Linked Polyethylene Insulation, High Heat resistant (90°C), 2: Suitable for Dry and Wet Locations

Manufacturing Standards: UL 44, NTC-3277. Thermo set-Insulated Wires and Cables.

3.393.854.455.976.908.099.58

11.1012.1013.2314.5015.9217.6218.9620.2221.3823.4826.1827.9328.7729.5731.1232.56

2.083.315.268.37

13.3021.1533.6342.4153.4867.4385.03107.2126.7152.0177.3202.7253.4304.0354.7380.0405.4456.0506.7

BBBBBBBBBBBBBBBBBBBBBBB

1.792.252.853.594.525.717.208.189.18

10.3111.5813.0014.1815.5216.7817.9420.0422.0023.7524.5925.3926.9428.38

0.760.760.761.141.141.141.141.401.401.401.401.401.651.651.651.651.652.032.032.032.032.032.03

8.455.313.342.101.32

0.8310.5230.4150.3290.2610.2070.1640.1390.116

0.09920.08680.06940.05780.04960.04630.04340.03860.0347

26395896

146223344435541674841

105112481487172519632437293934123649388643584830

35405580

105140190220260300350405455505570615700780855885920985

1055

253040557595

130150170195225260290320350380430475520535555585615

141210

86421

1/02/03/04/0

250300350400500600700750800900

1000

7777777

19191919193737373737616161616161

SIZEAWG / kcmil

CONDUCTORDIAMETER

(mm)

INSULATIONTHICKNESS

(mm)

APPROX.TOTAL

WEIGHT(kg/km)

DC RESISTANTAT 20°C¹(ohm/km)

AMPACITY²(A)3

AMPACITY²(A)4

DIAMETEROVER

INSULATION(mm)

CROSSSECTION

(mm2)

STRANDSNo.

STRANDINGCLASS

Page 4: Low voltage cables

10

Cables Type XHHW-2 600VCross (X) Linked Polyethylene Insulation, High Heat resistant (90°C), 2: Suitable for Dry and Wet Locations

Manufacturing Standards: UL 44, NTC-3277. Thermo set-Insulated Wires and Cables.

133152175235272318377437476521571627694747796842924

103111001133116412251282

0.003230.005130.00815

0.01300.02060.03280.05210.06570.0829

0.1050.1320.1660.1960.2360.2750.3140.3930.4710.5500.5890.6280.7070.785

BBBBBBBBBBBBBBBBBBBBBBB

7089

112141178225283322361406456512558611661706789866935968

100010611117

3030304545454555555555556565656565808080808080

2.581.621.02

0.6410.4030.2530.1590.1260.100

0.07950.06300.05000.04230.03530.03020.02640.02120.01760.01510.01410.01320.01180.0106

1826396598

150231292364453565707838999

115913191638197522932452261129293246

35405580

105140190220260300350405455505570615700780855885920985

1055

253040557595

130150170195225260290320350380430475520535555585615

141210

86421

1/02/03/04/0

250300350400500600700750800900

1000

7777777

19191919193737373737616161616161

Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2. 90°C conductor temperature, 30°C ambient temperature, According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. One single conductor at free air at 30°C ambient temperature.4. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature.5. According to NEC NTC 2050 the minimun size for use in Tray Cables must be 1/0 AWG for phase conductors, and 4 AWG for grounding conductors.6. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

SIZEAWG / kcmil

CONDUCTORDIAMETER

(mils)

INSULATIONTHICKNESS

(mils)

APPROX.TOTAL

WEIGHT(pound/1000ft)

DC RESISTANTAT 20°C¹

(ohm/1000ft)

AMPACITY²(A)3

AMPACITY²(A)4

DIAMETEROVER

INSULATION(mils)

CROSSSECTION(sq inches)

STRANDSNo.

STRANDING(mils)

Page 5: Low voltage cables

11

Rubber or Thermoset Insulation, High Heat Resistant (90°C) for Dry LocationsRubber or Thermoset Insulation, Heat Resistant (90°C), 2: Suitable for Dry and Wet LocationsUnderground Service Entrance Thermoset Insulation, Heat Resistant (90°C), 2: Suitable for Dry and Wet Locations

Description

Soft copper conductor, XLPE insulated.

Construction

ConductorCompressed Stranded Soft copper.

InsulationCross Linked Polyethylene (XLPE 90°C).Options

Aluminum Conductor, XLPE SR (Sunlight resistant) insulation.For sizes greater than 1/0 AWG, Type Tray Cable (TC).

Characteristics

Operating temperatureDry locations, RHH, RHW-2 and USE-2 90°•'3fC.Wet locations, RHW-2 and USE-2 90°•'3fC.Wet locations, RHH 75°C.

Operating Voltage600 V, RHH, RHW-2 and USE-2.2000 V, RHH y RHW-2.

RHH/RHW2/USE-2 Cables

Page 6: Low voltage cables

12

Uses and Applications

General purpose for power and control circuits, industrial and buildingwiring. When used as USE-2 conductor, can be installed in undergroundservice entrance and in directed buried. Abrasion and moisture resistantinsulation, its dimensions permits optimal filled in tubes and ducts.Pass VW-1 Vertical flame Test.

Standards and Specifications

ASTM B3, NTC-ICONTEC 359. Soft copper wire.ASTM B8, NTC-ICONTEC 307. Concentric Lay Stranded copperconductors.ASTM B787. 19 Wire Combination Unilay Stranded Copper conductorsfor subsequent insulationUL 1581, NTC-3203. Reference Standard for Electrical Wires, Cablesand Flexible Cords.UL 44, NTC-3277. Thermo set-Insulated Wires and Cables.

Certifications

CENTELSA RHH / RHW-2 / USE-2 Cables type, are certified by:UL 44 File E137698, for RHH y RHW-2.UL 854 File E207803, for USE-2.

Note: Other configurations and sizes not specified herein are availableupon request.

Page 7: Low voltage cables

13

Cables Type RHH / RHW-2 / USE-2 600V (Internacional Unit System)Rubber or Thermoset Insulation, High Heat Resistant (90°C) for Dry LocationsRubber or Thermoset Insulation, Heat Resistant (90°C), 2: Suitable for Dry and Wet LocationsUnderground Service Entrance Thermoset Insulation, Heat Resistant (90°C), 2: Suitable for Dry and Wet Locations

Manufacturing Standard: UL 44, NTC-3277. Thermo set-Insulated Wires and Cables. UL 854, NTC-4564 Service entrance Cables (For USE-2)

Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2. 90°C conductor temperature, 30°C ambient temperature, According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. One single conductor at free air at 30°C ambient temperature.4. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature.5. According to NEC NTC 2050 the minimun size for use in Tray Cables must be 1/0 AWG for phase conductors, and 4 AWG for grounding conductors.6. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

4.174.635.236.757.688.87

10.3612.3613.3614.4915.7617.1819.1420.4821.7422.9025.0027.7429.4930.3331.1332.6834.12

2.083.315.268.37

13.3021.1533.6342.4153.4867.4385.03107.2126.7152.0177.3202.7253.4304.0354.7380.0405.4456.0506.7

BBBBBBBBBBBBBBBBBBBBBBB

1.792.252.853.594.525.717.208.189.18

10.3111.5813.0014.1815.5216.7817.9420.0422.0023.7524.5925.3926.9428.38

1.141.141.141.521.521.521.522.032.032.032.032.032.412.412.412.412.412.792.792.792.792.792.79

8.455.313.342.101.32

0.8310.5230.4150.3290.2610.2070.1640.1390.116

0.09920.08680.06940.05780.04960.04630.04340.03860.0347

314465

105155234357460568704873

108612951537177920192499300934883727396544424917

35405580

105140190220260300350405455505570615700780855885920985

1055

253040557595

130150170195225260290320350380430475520535555585615

141210

86421

1/02/03/04/0

250300350400500600700750800900

1000

7777777

19191919193737373737616161616161

SIZEAWG / kcmil

CROSSSECTION

(mm²)

CONDUCTORDIAMETER

(mm)

DIAMETEROVER

INSULATION(mm)

DC RESISTANCEAT 20°C 1(ohm/km)

AMPACITY²(A)3

AMPACITY²(A)4

INSULATIONTHICKNESS

(mm)

STRANDSNo.

STRANDINGCLASS

APPROX.TOTAL

WEIGHT(kg/km)

Page 8: Low voltage cables

14

Cables Type RHH / RHW-2 / USE-2 600VRubber or Thermoset Insulation, High Heat Resistant (90°C) for Dry LocationsRubber or Thermoset Insulation, Heat Resistant (90°C), 2: Suitable for Dry and Wet LocationsUnderground Service Entrance Thermoset Insulation, Heat Resistant (90°C), 2: Suitable for Dry and Wet Locations

Manufacturing Standard: UL 44, NTC-3277. Thermo set-Insulated Wires and Cables. UL 854, NTC-4564 Service entrance Cables (For USE-2).

164182206266303349408487526571620676753806856901984

109211611194122612871343

0.003230.005130.00815

0.01300.02060.03280.05210.06570.0829

0.1050.1320.1660.1960.2360.2750.3140.3930.4710.5500.5890.6280.7070.785

BBBBBBBBBBBBBBBBBBBBBBB

7089

112141178225283322361406456512558611661706789866935968

100010611117

4545456060606080808080809595959595

110110110110110110

2.581.621.02

0.6410.4030.2530.1590.1260.100

0.07950.06300.05000.04230.03530.03020.02640.02120.01760.01510.01410.01320.01180.0106

21304470

104157240309382473587730870

1033119513571680202223442504266529853305

35405580

105140190220260300350405455505570615700780855885920985

1055

253040557595

130150170195225260290320350380430475520535555585615

141210

86421

1/02/03/04/0

250300350400500600700750800900

1000

7777777

19191919193737373737616161616161

SIZEAWG / kcmil

CROSSSECTION(sq inches)

CONDUCTORDIAMETER

(mils)

DIAMETEROVER

INSULATION(mils)

DC RESISTANCEAT 20°C 1

(ohm/1000ft)

AMPACITY²(A)3

AMPACITY²(A)4

INSULATIONTHICKNESS

(mils)

STRANDSNo.

STRANDINGCLASS(mils)

APPROX.TOTAL

WEIGHT(pounds/1000ft)

Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2. 90°C conductor temperature, 30°C ambient temperature, According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. One single conductor at free air at 30°C ambient temperature.4. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature.5. According to NEC NTC 2050 the minimun size for use in Tray Cables must be 1/0 AWG for phase conductors, and 4 AWG for grounding conductors.

6. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

Page 9: Low voltage cables

15

Cables Type RHH / RHW-2 / USE-2 2000V (Internacional Unit System)Rubber or Thermoset Insulation, High Heat Resistant (90°C) for Dry Locations.Rubber or Thermoset Insulation, Heat Resistant (90°C), 2: Suitable for Dry and Wet Locations.

Manufacturing Standard: UL 44, NTC-3277. Thermo set-Insulated Wires and Cables.

Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2. T90°C conductor temperature, 30°C ambient temperature, According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. One single conductor at free air at 30°C ambient temperature.4. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature.5. According to NEC NTC 2050 the minimun size for use in Tray Cables must be 1/0 AWG for phase conductors, and 4 AWG for grounding conductors.6. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

4.955.416.017.298.229.41

10.9012.9013.9015.0316.3017.7219.6821.0222.2823.4425.5428.2830.0330.8731.6733.2234.66

2.083.315.268.37

13.3021.1533.6342.4153.4867.4385.03107.2126.7152.0177.3202.7253.4304.0354.7380.0405.4456.0506.7

BBBBBBBBBBBBBBBBBBBBBBB

1.792.252.853.594.525.717.208.189.18

10.3111.5813.0014.1815.5216.7817.9420.0422.0023.7524.5925.3926.9428.38

1.521.521.521.781.781.781.782.292.292.292.292.292.672.672.672.672.673.053.053.053.053.053.05

8.455.313.342.101.32

0.8310.5230.4150.3290.2610.2070.1640.1390.116

0.09920.08680.06940.05780.04960.04630.04340.03860.0347

375172

111163242367471580717888

110213121556179920402522303535153754399444724948

35405580

105140190220260300350405455505570615700780855885920985

1055

253040557595

130150170195225260290320350380430475520535555585615

141210

86421

1/02/03/04/0

250300350400500600700750800900

1000

7777777

19191919193737373737616161616161

SIZEAWG / kcmil

CROSSSECTION

(mm²)

CONDUCTORDIAMETER

(mm)

DIAMETEROVER

INSULATION(mm)

DC RESISTANCEAT 20°C 1(ohm/km)

AMPACITY²(A)3

AMPACITY²(A)4

INSULATIONTHICKNESS

(mm)

STRANDSNo.

STRANDINGCLASS

APPROX.TOTAL

WEIGHT(kg/km)

Page 10: Low voltage cables

16

Cables Type RHH / RHW-2 / USE-2 2000VRubber or Thermoset Insulation, High Heat Resistant (90°C) for Dry Locations.Rubber or Thermoset Insulation, Heat Resistant (90°C), 2: Suitable for Dry and Wet Locations.

Manufacturing Standard: UL 44, NTC-3277. Thermo set-Insulated Wires and Cables.

195213236287324370429508547592642698775828877923

1006111311821215124713081365

0.003230.005130.00815

0.01300.02060.03280.05210.06570.0829

0.1050.1320.1660.1960.2360.2750.3140.3930.4710.5500.5890.6280.7070.785

BBBBBBBBBBBBBBBBBBBBBBB

7089

112141178225283322361406456512558611661706789866935968

100010611117

606060707070709090909090

105105105105105120120120120120120

2.581.621.02

0.6410.4030.2530.1590.1260.100

0.07950.06300.05000.04230.03530.03020.02640.02120.01760.01510.01410.01320.01180.0106

25344875

109163247317390482597741882

1046120913711695203923622523268430053326

35405580

105140190220260300350405455505570615700780855885920985

1055

253040557595

130150170195225260290320350380430475520535555585615

141210

86421

1/02/03/04/0

250300350400500600700750800900

1000

7777777

19191919193737373737616161616161

Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2. T90°C conductor temperature, 30°C ambient temperature, According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. One single conductor at free air at 30°C ambient temperature.4. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature.5. According to NEC NTC 2050 the minimun size for use in Tray Cables must be 1/0 AWG for phase conductors, and 4 AWG for grounding conductors.6. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

SIZEAWG / kcmil

CROSSSECTION

(mils)

CONDUCTORDIAMETER

(mils)

DIAMETEROVER

INSULATION(mils)

DC RESISTANCEAT 20°C 1

(ohm/1000ft)

AMPACITY²(A)3

AMPACITY²(A)4

INSULATIONTHICKNESS

(mils)

STRANDSNo.

STRANDINGCLASS

APPROX.TOTAL

WEIGHT(pound/1000ft)

Page 11: Low voltage cables

17

Description

Soft copper conductor, XLPE or PE insulated and an PVC external jacket.

Construction

ConductorCompressed Stranded Soft copper.

InsulationThermoplastic Polyethylene (PE 75°•'3fC), for PE-PVC.Cross Linked Polyethylene (XLPE 90°•'3fC), for XLPE-PVC.

OptionsAluminum Conductor, PVC-LS (Low smoke emissions) jacket and PVC SR(Sunlight resistant) jacketFor sizes greater than 1/0 AWG, Type Tray Cable (TC).

Characteristics

Operating temperatureDry and wet locations.75°C for TTU PE-PVC.90°C for TTU XLPE-PVC.

Operating Voltage600 V and 2000 V

Uses and Applications

Industrial installations, distribution and lighting systems. Dry or wet locationsinstallations, in Tray Cable, ducts or raceways. Sizes 8 AWG and greater areuseful for directed burial.

TTU CablesThermoplastic (or Thermoset) Insulation, Thermoplastic Jacket. Underground

Page 12: Low voltage cables

18

TTU design join excellent PE electrical properties, electrical andmechanical XLPE properties as insulation with mechanical and flameretardancy PVC properties as external jacket.

Standards and Specifications

CENTELSA TTU Cables are manufactured under the followingstandards:

ASTM B3, NTC-ICONTEC 359. Soft copper wire.ASTM B8, NTC-ICONTEC 307. Concentric Lay Stranded copperconductors.ASTM B787. 19 Wire Combination Unilay Stranded Copper conductorsfor subsequent insulation.UL 1581, NTC-3203. Reference Standard for Electrical Wires, Cablesand Flexible Cords.ICEA S-95-658, NTC-ICONTEC 1099-1. Power Cables rated 2000volts or less for the Distribution of Electrical Energy.

Certifications

CENTELSA TTU cables are certified by CIDET (Colombia). Cert. No.408.

Note: Other configurations and sizes not specified herein are availableupon request.

Page 13: Low voltage cables

19

Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2. 75°C for PE insulation, 90°C conductor temperature nfor XLPE insulation, 30°C ambient temperature, According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. One single conductor at free air at 30°C ambient temperature.4. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature.5. According to NEC NTC 2050 the minimun size for use in Tray Cables must be 1/0 AWG for phase conductors, and 4 AWG for grounding conductors.6. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

Cables Type TTU 600V (International Unit System)Thermoplastic (or Thermoset) Insulation, Thermoplastic Jacket. Underground

Manufacturing Standard: ICEA S-95-658, NTC-ICONTEC 1099-1. Power Cables rated 2000 volts or less for the Distribution of Electrical Energy.

DIAMETEROVER

JACKET(mm)

SIZEAWG /kcmil

DIAMETEROVER

INSULATION(mm)

JACKETTHICKNESS

(mm)

APPROX.TOTAL

WEIGHT(kg/km)

DCRESISTANCE

AT 20°C1

(ohm/km)

STRANDINGCLASS

XLPE INSULATIONPE INSULATION

CROSSSECTION

(mm2)

CONDUCTORDIAMETER

(mm)

INSULATIONTHICKNESS

(mm)

AMPACITY 2

(A)4AMPACITY 2

(A)3AMPACITY 2

(A)4AMPACITY 2

(A)3STRANDS

No.

3.383.854.445.966.898.089.57

11.0912.0913.2214.4915.9117.6118.9520.2121.3723.4726.1827.9328.7729.5731.1232.56

2.083.315.268.37

13.3021.1533.6342.4153.4867.4385.03107.2126.7152.0177.3202.7253.4304.0354.7380.0405.4456.0506.7

BBBBBBBBBBBBBBBBBBBBBBB

1.792.252.853.594.525.717.208.189.18

10.3111.5813.0014.1815.5216.7817.9420.0422.0023.7524.5925.3926.9428.38

0.760.760.761.141.141.141.141.401.401.401.401.401.651.651.651.651.652.032.032.032.032.032.03

202535506585

115130150175200230255285310335380420460475490520545

3035507095

125170195230265310360405455505545620690755785815870935

253040557595

130150170195225260290320350380430475520535555585615

8.455.313.342.101.32

0.8310.5230.4150.3290.2610.2070.1640.1390.116

0.09920.08680.06940.05780.04960.04630.04340.03860.0347

35405580

105140190220260300350405455505570615700780855885920985

1055

0.380.380.380.380.760.760.761.141.141.141.141.141.141.651.651.651.651.651.651.651.651.651.65

141210

86421

1/02/03/04/0

250300350400500600700750800900

1000

7777777

19191919193737373737616161616161

4.224.695.286.808.499.67

11.1713.4614.4615.5916.8618.2819.9822.3923.6424.8026.9029.6131.3632.2033.0034.5636.00

324666

106170251376494605743916

113213351632187921252614313036163858410045835064

Page 14: Low voltage cables

20

Cables Type TTU 600VThermoplastic (or Thermoset) Insulation, Thermoplastic Jacket. Underground

Manufacturing Standard: ICEA S-95-658, NTC-ICONTEC 1099-1.Power Cables rated 2000 volts or less for the Distribution of Electrical Energy.

133152175235271318377437476521571626693746796841924

103111001133116412251282

0.003230.005130.00815

0.01300.02060.03280.05210.06570.0829

0.1050.1320.1660.1960.2360.2750.3140.3930.4710.5500.5890.6280.7070.785

BBBBBBBBBBBBBBBBBBBBBBB

7089

112141178225283322361406456512558611661706789866935968

100010611117

3030304545454555555555556565656565808080808080

202535506585

115130150175200230255285310335380420460475490520545

3035507095

125170195230265310360405455505545620690755785815870935

253040557595

130150170195225260290320350380430475520535555585615

2.581.621.02

0.6410.4030.2530.1590.1260.100

0.07950.06300.05000.04230.03530.03020.02640.02120.01760.01510.01410.01320.01180.0106

35405580

105140190220260300350405455505570615700780855885920985

1055

1515151530303045454545454565656565656565656565

141210

86421

1/02/03/04/0

250300350400500600700750800900

1000

7777777

19191919193737373737616161616161

166185208268334381440530569614664720787881931976

1059116612351268129913601417

22314471

114168253332406499615761897

1097126314281756210424302593275530803403

DIAMETEROVER

JACKET(mils)

SIZEAWG /kcmil

DIAMETEROVER

INSULATION(mils)

JACKETTHICKNESS

(mils)

APPROX.TOTAL

WEIGHT(pounds/1000ft)

DCRESISTANCE

AT 20°C1

(ohm/1000ft)

STRANDINGCLASS

XLPE INSULATIONPE INSULATION

CROSSSECTION(sq inches)

CONDUCTORDIAMETER

(mils)

INSULATIONTHICKNESS

(mils)

AMPACITY 2

(A)4AMPACITY 2

(A)3AMPACITY 2

(A)4AMPACITY 2

(A)3STRANDS

No.

Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2. 75°C for PE insulation, 90°C conductor temperature nfor XLPE insulation, 30°C ambient temperature, According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. One single conductor at free air at 30°C ambient temperature.4. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature.5. According to NEC NTC 2050 the minimun size for use in Tray Cables must be 1/0 AWG for phase conductors, and 4 AWG for grounding conductors.6. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

Page 15: Low voltage cables

21

Cables Type TTU 600V (International Unit System)Thermoplastic (or Thermoset) Insulation, Thermoplastic Jacket. Underground

Manufacturing Standard: ICEA S-95-658, NTC-ICONTEC 1099-1.Power Cables rated 2000 volts or less for the Distribution of Electrical Energy.

4.164.635.226.507.448.62

10.1111.6112.6113.7415.0116.4318.1319.4720.7321.8924.7626.7128.4729.3130.1131.6633.10

2.083.315.268.37

13.3021.1533.6342.4153.4867.4385.03107.2126.7152.0177.3202.7253.4304.0354.7380.0405.4456.0506.7

BBBBBBBBBBBBBBBBBBBBBBB

1.792.252.853.594.525.717.208.189.18

10.3111.5813.0014.1815.5216.7817.9420.0422.0023.7524.5925.3926.9428.38

1.141.141.141.401.401.401.401.651.651.651.651.651.901.901.901.902.292.292.292.292.292.292.29

202535506585

115130150175200230255285310335380420460475490520545

3035507095

125170195230265310360405455505545620690755785815870935

253040557595

130150170195225260290320350380430475520535555585615

8.455.313.342.101.32

0.8310.5230.4150.3290.2610.2070.1640.1390.116

0.09920.08680.06940.05780.04960.04630.04340.03860.0347

35405580

105140190220260300350405455505570615700780855885920985

1055

0.380.380.380.760.760.760.761.141.141.141.141.141.651.651.651.651.651.651.651.651.651.651.65

141210

86421

1/02/03/04/0

250300350400500600700750800900

1000

7777777

19191919193737373737616161616161

5.005.466.058.109.03

10.2111.7113.9814.9816.1117.3818.8021.5622.9124.1625.3228.1930.1531.9032.7433.5435.0936.53

385273

125178259386505617756930

114714011651189921452668315536423885412746115093

Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2. 75°C for PE insulation, 90°C conductor temperature nfor XLPE insulation, 30°C ambient temperature, According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. One single conductor at free air at 30°C ambient temperature.4. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature.5. According to NEC NTC 2050 the minimun size for use in Tray Cables must be 1/0 AWG for phase conductors, and 4 AWG for grounding conductors.6. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

DIAMETEROVER

JACKET(mm)

SIZEAWG /kcmil

DIAMETEROVER

INSULATION(mm)

JACKETTHICKNESS

(mm)

APPROX.TOTAL

WEIGHT(kg/km)

DCRESISTANCE

AT 20°C1

(ohm/km)

STRANDINGCLASS

XLPE INSULATIONPE INSULATION

CROSSSECTION

(mm2)

CONDUCTORDIAMETER

(mm)

INSULATIONTHICKNESS

(mm)

AMPACITY 2

(A)4AMPACITY 2

(A)3AMPACITY 2

(A)4AMPACITY 2

(A)3STRANDS

No.

Page 16: Low voltage cables

22

Cables Type TTU 600VThermoplastic (or Thermoset) Insulation, Thermoplastic Jacket. Underground

Manufacturing Standard: ICEA S-95-658, NTC-ICONTEC 1099-1.Power Cables rated 2000 volts or less for the Distribution of Electrical Energy.

164182205256293339398457496541591647714767816862975

105211211154118512461303

0.003230.005130.00815

0.01300.02060.03280.05210.06570.0829

0.1050.1320.1660.1960.2360.2750.3140.3930.4710.5500.5890.6280.7070.785

BBBBBBBBBBBBBBBBBBBBBBB

7089

112141178225283322361406456512558611661706789866935968

100010611117

4545455555555565656565657575757590909090909090

202535506585

115130150175200230255285310335380420460475490520545

3035507095

125170195230265310360405455505545620690755785815870935

253040557595

130150170195225260290320350380430475520535555585615

2.581.621.02

0.6410.4030.2530.1590.1260.100

0.07950.06300.05000.04230.03530.03020.02640.02120.01760.01510.01410.01320.01180.0106

35405580

105140190220260300350405455505570615700780855885920985

1055

1515153030303045454545456565656565656565656565

141210

86421

1/02/03/04/0

250300350400500600700750800900

1000

7777777

19191919193737373737616161616161

197215238319356402461551590634684740849902951997

1110118712561289132013821438

26354984

119174259340414508625771942

1109127614421793212024472611277430993423

DIAMETEROVER

JACKET(mils)

SIZEAWG /kcmil

DIAMETEROVER

INSULATION(mils)

JACKETTHICKNESS

(mils)

APPROX.TOTAL

WEIGHT(pounds/1000ft)

DCRESISTANCE

AT 20°C1

(ohm/1000ft)

STRANDING(mils)

XLPE INSULATIONPE INSULATION

CROSSSECTION(sq inches)

CONDUCTORDIAMETER

(mils)

INSULATIONTHICKNESS

(mils)

AMPACITY 2

(A)4AMPACITY 2

(A)3AMPACITY 2

(A)4AMPACITY 2

(A)3STRANDS

No.

Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2. 75°C for PE insulation, 90°C conductor temperature nfor XLPE insulation, 30°C ambient temperature, According to NEC and NTC 2050,

for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. One single conductor at free air at 30°C ambient temperature.4. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature.5. According to NEC NTC 2050 the minimun size for use in Tray Cables must be 1/0 AWG for phase conductors, and 4 AWG for grounding conductors.6. Data herein indicated are approximated and are subject to normal manufacturing tolerances.

Page 17: Low voltage cables

23

Cross (X) Linked Polyethilene Insulation, High Heat resistant (90°C), 2: Suitable for Dry and Wet Locations

Description

Three soft copper conductors PVC or XLPE insulated twisted and with overallPVC jacket.

Design

ConductorSoft stranded compressed copper.

InsulationPolyvinyl Chloride (PVC 75°C) flame retardant, for PVC-PVC insulation andjacket.Cross linked Polyethylene (XLPE 90°C), for XLPE-PVC insulation and jacket.

FillerFlame retardant Polyvinyl Chloride.

JacketFlame retardant Polyvinyl Chloride.

OptionsEPR insulation. Metallic shield in copper tape or copper wires. Groundingconductor- Armor in galvanized steel wires or galvanized steel tape or interlockedarmor tape aluminum or steel. Moisture barrier, PVC SR (Sunlight Resistant)jacket.

Characteristics

Operating temperatureDry and wet locations.75°C, for PVC-PVC insulation-jacket.90°C, for XLPE-PVC insulation-jacket.

Three Conductor Power CablesCross (X) Linked Polyethylene Insulation, High Heat resistant (90°C),2: Suitable for Dry and Wet Locations

Page 18: Low voltage cables

24

Operating Voltage600 V.

Optional2000 V.

Uses and Applications

General purpose in industrial installations for Low Voltage indoordistribution of electrical energy in low tension. Installation in dry or wetlocations, in ducts, raceway or buried direct. The design of PowerCable 3 - conductor combines the excellent electrical properties ofPE, and electrical and mechanical of XLPE like insulation materials,and the mechanical properties and PVC flame in the outer jacket. Inspecial applications the cable can be used under water. XLPE insulatedconductors have minor total diameters for the same voltage of operation,that PVC isolated ones.

Standards and Specifications

CENTELSA Power Cables are manufactured under the followingstandards:

ASTM B3, NTC-ICONTEC 359. Soft copper wire.ASTM B8, NTC-ICONTEC 307. Concentric Lay Stranded copperconductors.ASTM B787. 19 Wire Combination Unilay Stranded Copper conductorsfor subsequent insulation.UL 1581, NTC-3203. Reference Standard for Electrical Wires, Cablesand Flexible Cords.ICEA S-95-658, NTC-ICONTEC 1099-1. Power Cables rated 2000volts or less for the Distribution of Electrical Energy.IEC 228. Conductors for insulated cables (mm2 sizes).IEC 60502-1. Cables for 1kV Voltages (mm2 sizes).

Certifications

CENTELSA Power Cables are certified by CIDET (Colombia). Cert.No. 1668.

Page 19: Low voltage cables

25

Phases identification

PVC-PVC Cables are identified by colored phases black, white and red. Blackjacket.XLPE-PVC Cables are identified by numbered black phases. Black jacket.

Note: Other configurations and sizes not specified herein are available uponrequest.

Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2. In race way, or direct burial, 75°C conductor temperature, 30°C ambient temperature.3. Data herein indicated are approximated and are subject to normal manufacturing tolerances.

6.757.688.87

10.3612.3613.3614.4915.7617.1819.1420.4821.7422.9025.00

8.3713.3021.1533.6342.4153.4867.4385.03107.2126.7152.0177.3202.7253.4

BBBBBBBBBBBBBB

3.594.525.717.208.189.18

10.3111.5813.0014.1815.5216.7817.9420.04

1.521.521.521.522.032.032.032.032.032.412.412.412.412.41

2.101.32

0.8310.5230.4150.3290.2610.2070.1640.1390.116

0.09920.08680.0694

541737

108915542007240830713702463955006392727881549886

17.7119.7223.2926.5030.8232.9737.4140.1444.7648.9851.8854.5957.0861.62

506585

115130150175200230255285310335380

14.5516.5619.1122.3226.6428.7931.2333.9637.0241.2444.1446.8549.3453.88

86421

1/02/03/04/0

250300350400500

7777

19191919193737373737

------

1.001.001.001.001.001.001.001.00

1.521.522.032.032.032.032.032.032.792.792.792.792.792.79

DIAMETEROVER

JACKET(mm)

SIZEAWG /kcmil

DIAMETEROVER

INSULATION(mm)

JACKETTHICKNESS

(mm)

APPROX.TOTAL

WEIGHT(kg/km)

DCRESISTANCE

AT 20°C1

(ohm/km)

STRANDINGCLASS

CROSSSECTION

(mm2)

CONDUCTORDIAMETER

(mm)

INSULATIONTHICKNESS

(mm)

AMPACITY 2

(A)STRANDS

No.ASSEMBLYDIAMETER

(mm)

FILLERTHICKNESS

(mm)

Three Conductors Cables PVC-PVC 600V (International Unit System)

Manufacturing Standard: ICEA S-95-658, NTC-ICONTEC 1099-1. Power Cables rated 2000 volts or less for the Distribution of Electrical Energy.

Page 20: Low voltage cables

26

Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2. In race way, or direct burial, 75°C conductor temperature, 30°C ambient temperature.3. Data herein indicated are approximated and are subject to normal manufacturing tolerances.

266303349408487526571620676753806856901984

0.01300.02060.03280.05210.06570.0829

0.1050.1320.1660.1960.2360.2750.3140.393

BBBBBBBBBBBBBB

141178225283322361406456512558611661706789

6060606080808080809595959595

0.6410.4030.2530.1590.1260.100

0.07950.06300.05000.04230.03530.03020.02640.0212

363496732

10441349161920642488311836964296489154806644

697776917

10431213129814731580176219282042214922472426

506585

115130150175200230255285310335380

573652752879

1049113312291337145716241738184519432121

86421

1/02/03/04/0

250300350400500

7777

19191919193737373737

------

3939393939393939

6060808080808080

110110110110110110

Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2. In race way, or direct burial, 90°C conductor temperature, 30°C ambient temperature.3. Data herein indicated are approximated and are subject to normal manufacturing tolerances.

5.976.908.099.58

11.1012.1013.2314.5015.9217.6218.9620.2221.3823.48

8.3713.3021.1533.6342.4153.4867.4385.03107.2126.7152.0177.3202.7253.4

BBBBBBBBBBBBBB

3.594.525.717.208.189.18

10.3111.5813.0014.1815.5216.7817.9420.04

1.141.141.141.141.401.401.401.401.401.651.651.651.651.65

2.101.32

0.8310.5230.4150.3290.2610.2070.1640.1390.116

0.09920.08680.0694

460646930

14241787217126493409416550735936679576469333

16.0318.0420.5924.8228.1030.2532.6937.4340.4845.7048.6051.3253.8158.34

557595

130150170195225260290320350380430

12.8714.8817.4320.6423.9226.0728.5131.2534.3037.9640.8643.5846.0750.60

86421

1/02/03/04/0

250300350400500

7777

19191919193737373737

-------

1.001.001.001.001.001.001.00

1.521.521.522.032.032.032.032.032.032.792.792.792.792.79

Three Conductors Cables PVC-PVC 600V

Manufacturing Standard: ICEA S-95-658, NTC-ICONTEC 1099-1.Power Cables rated 2000 volts or less for the Distribution of Electrical Energy.

DIAMETEROVER

JACKET(mils)

SIZEAWG /kcmil

DIAMETEROVER

INSULATION(mils)

JACKETTHICKNESS

(mils)

APPROX.TOTAL

WEIGHT(pound/1000ft)

DCRESISTANCE

AT 20°C1

(ohm/1000ft)

STRANDING(mils)

CROSSSECTION(sq inches)

CONDUCTORDIAMETER

(mils)

INSULATIONTHICKNESS

(mils)

AMPACITY 2

(A)STRANDS

No.ASSEMBLYDIAMETER

(mils)

FILLERTHICKNESS

(mils)

Three Conductors Cables XLPE-PVC 600V (International Unit System)

Manufacturing Standard: ICEA S-95-658, NTC-ICONTEC 1099-1.Power Cables rated 2000 volts or less for the Distribution of Electrical Energy.

DIAMETEROVER

JACKET(mm)

SIZEAWG /kcmil

DIAMETEROVER

INSULATION(mm)

JACKETTHICKNESS

(mm)

APPROX.TOTAL

WEIGHT(kg/km)

DCRESISTANCE

AT 20°C1

(ohm/km)

STRANDINGCLASS

CROSSSECTION

(mm2)

CONDUCTORDIAMETER

(mm)

INSULATIONTHICKNESS

(mm)

AMPACITY 2

(A)STRANDS

No.ASSEMBLYDIAMETER

(mm)

FILLERTHICKNESS

(mm)

Page 21: Low voltage cables

27

235272318377437476521571627694747796842924

0.01300.02060.03280.05210.06570.0829

0.1050.1320.1660.1960.2360.2750.3140.393

BBBBBBBBBBBBBB

141178225283322361406456512558611661706789

4545454555555555556565656565

0.6410.4030.2530.1590.1260.100

0.07950.06300.05000.04230.03530.03020.02640.0212

309434625957

1201145917802291279934093989456751396272

631710810977

1106119112871474159417991914202021182297

557595

130150170195225260290320350380430

507586686813942

102611231230135014951609171618141992

86421

1/02/03/04/0

250300350400500

7777

19191919193737373737

-------

39393939393939

606060808080808080

110110110110110

Notes: 1. Designated Voltage Uo/U means Uo rated voltage phase-neutral, U rated voltage phase-phase.2. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.3. In race way, or direct burial, 75°C conductor temperature, 30°C ambient temperature.4. Data herein indicated are approximated and are subject to normal manufacturing tolerances.

5.826.808.389.46

11.1812.6914.7116.2018.1420.1522.83

10.016.025.035.050.070.095.0

120.0150.0185.0240.0

22222222222

3.724.705.886.968.269.77

11.3912.8814.4015.9918.29

1.001.001.201.201.401.401.601.601.802.002.20

1.761.10

0.7030.5020.3520.2510.1850.1470.117

0.09510.0733

530752

111514682018272437224600570770148996

16.2818.3921.8024.1327.8331.5137.0240.6545.0349.7855.96

507090

110140170205240275310365

12.5414.6518.0620.3924.0927.3531.7034.9139.0943.4249.20

10162535507095

120150185240

7777

19191937373737

------

0.500.500.500.500.50

1.801.801.801.801.802.002.102.302.402.602.80

Three Conductors Cables XLPE-PVC 600V

Manufacturing Standard: ICEA S-95-658, NTC-ICONTEC 1099-1.Power Cables rated 2000 volts or less for the Distribution of Electrical Energy.

Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2. In race way, or direct burial, 90°C conductor temperature, 30°C ambient temperature.3. Data herein indicated are approximated and are subject to normal manufacturing tolerances.

DIAMETEROVER

JACKET(mils)

SIZEAWG /kcmil

DIAMETEROVER

INSULATION(mils)

JACKETTHICKNESS

(mils)

APPROX.TOTAL

WEIGHT(pound/1000ft)

DCRESISTANCE

AT 20°C1

(ohm/1000ft)

STRANDING(mils)

CROSSSECTION(sq inches)

CONDUCTORDIAMETER

(mils)

INSULATIONTHICKNESS

(mils)

AMPACITY 2

(A)STRANDS

No.ASSEMBLYDIAMETER

(mils)

FILLERTHICKNESS

(mils)

Three Conductor Power Cable Type PVC-PVC 0.6/1 kV ( mm2 Sizes)

Manufacturing Standard: IEC 60502-1 Cables for 1 kV Voltages.

DIAMETEROVER

JACKET(mm)

SIZEAWG /kcmil

DIAMETEROVER

INSULATION(mm)

JACKETTHICKNESS

(mm)

APPROX.TOTAL

WEIGHT(kg/km)

DCRESISTANCE

AT 20°C1

(ohm/km)

STRANDINGCLASS

CROSSSECTION

(mm2)

CONDUCTORDIAMETER

(mm)

INSULATIONTHICKNESS

(mm)

AMPACITY 2

(A)STRANDS

No.ASSEMBLYDIAMETER

(mm)

FILLERTHICKNESS

(mm)

Page 22: Low voltage cables

28

Notes: 1. Designated Voltage Uo/U means Uo rated voltage phase-neutral, U rated voltage phase-phase.2. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.3. In race way, or direct burial, 90°C conductor temperature, 30°C ambient temperature.4. Data herein indicated are approximated and are subject to normal manufacturing tolerances.

5.206.187.788.86

10.3612.0513.6715.3817.3219.3121.83

10.016.025.035.050.070.095.0

120.0150.0185.0240.0

22222222222

3.724.705.886.968.269.77

11.3912.8814.4015.9918.29

0.700.700.900.901.001.101.101.201.401.601.70

1.761.10

0.7030.5020.3520.2510.1850.1470.117

0.09510.0733

473686

103313751883257834114373544567078602

14.9517.0620.5122.8326.0729.9333.6238.6843.0647.7753.60

6080

105130160195235270310350410

11.2113.3216.7719.0922.3325.9729.4633.1437.3241.6147.04

10162535507095

120150185240

7777

19191937373737

-------

0.500.500.500.50

1.801.801.801.801.801.902.002.202.302.502.70

Three Conductor Power Cable Type XLPE-PVC 0.6/1 kV ( mm2 Sizes)

Manufacturing Standard: IEC 60502-1 Cables for 1 kV Voltages.

DIAMETEROVER

JACKET(mm)

SIZEAWG /kcmil

DIAMETEROVER

INSULATION(mm)

JACKETTHICKNESS

(mm)

APPROX.TOTAL

WEIGHT(kg/km)

DCRESISTANCE

AT 20°C1

(ohm/km)

STRANDINGCLASS

CROSSSECTION

(mm2)

CONDUCTORDIAMETER

(mm)

INSULATIONTHICKNESS

(mm)

AMPACITY 2

(A)STRANDS

No.ASSEMBLYDIAMETER

(mm)

FILLERTHICKNESS

(mm)

Page 23: Low voltage cables

29

Service EntranceType SEU & SERService Entrance Cable Unarmored or U-shapedService Entrance Cable Round

Description

Service Entrance SEU: one or two XHHW-2 insulated conductors, paralleled,with concentric neutral, reinforced tape and PVC jacket.

Service Entrance SER: two or three XHHW-2 insulated conductors, twistedtogether with or without bare grounding conductor, reinforced tape and PVCjacket.

Construction

ConductorSoft copper stranded and compressed.

InsulationCross Linked Polyethylene (XLPE 90°C).

Design

Service Entrance Type U, SEU: Round configuration for one phase conductorand neutral, flan configuration for two phase conductors and neutral.

NeutralService Entrance SEU : soft copper wires applied concentrically around phaseswith SZ technology (UL 854 Section 15.4)Service Entrance SER: soft copper stranded, twisted together with phases

Binder TapeService Entrance SEU: polyester tape over neutral conductorService Entrance SER: polyester tape over assembly.

Page 24: Low voltage cables

30

JacketFlame Retardant and Sunlight resistant PVC.

OptionsTHWN-2 Conductors. Jacket with PVC LS (LOW Smoke emission).Aluminum conductors.

Characteristics

Operating TemperatureDry and wet locations 90°C.Operating Voltage600 V.

Uses and Applications

Service Entrance or Drop Cable up to Service Entrance Equipmentand to general breaker. May be used for branch circuits according toNEC and NTC 2050.

Standards and Specifications

CENTELSA Service Entrance Cables are manufactured under thefollowing standards:

ASTM B3, NTC-359. Soft copper wires.ASTM B8, NTC-307. Concentric Lay Stranded copper conductors.ASTM B787. 19 Wire Combination Unilay Stranded Copper conductorsfor subsequent insulationUL 1581, NTC-3203. Reference Standard for Electrical Wires, Cablesand Flexible Cords.UL 854, NTC-ICONTEC 4564. Service Entrance Cables.

Certifications

CENTELSA Service Entrance Cables are certified by:

UL 854 File E207803.CIDET (Colombia). Cert. No. 00416.

Note: Other configurations and sizes not specified herein are availableupon request.

Page 25: Low voltage cables

31

Service Entrance Type SEU 600VService Entrance Cable Unarmored or U-shaped

Manufacturing Standard: UL 854, NTC 4564. Service Entrance Cables

Service Entrance Type SEU 600V (International System Unit)Service Entrance Cable Unarmored or U-shaped

Manufacturing Standard: UL 854, NTC 4564. Service Entrance Cables

Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature, 90°C conductor temperature. According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. LData herein indicated are approximated and are subject to normal manufacturing tolerances.

Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2.No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature, 90°C conductor temperature. According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. LData herein indicated are approximated and are subject to normal manufacturing tolerances.

4.185.966.898.089.574.185.966.898.089.575.966.898.089.57

5.268.37

13.3021.1533.63

5.268.37

13.3021.1533.63

8.3713.3021.1533.63

SOLIDBBBB

SOLIDBBBBBBBB

2.593.594.525.717.202.593.594.525.717.203.594.525.717.20

0.761.141.141.141.140.761.141.141.141.141.141.141.141.14

3.282.101.32

0.8310.523

3.282.101.32

0.8310.523

2.101.32

0.8310.523

6.829.36

10.5612.0813.99

6.90 x 11.089.45 x 15.42

10.65 x 17.5412.17 x 20.2514.09 x 23.66

9.45 x 15.4210.38 x 17.2811.83 x 19.9113.66 x 23.23

0.761.141.141.141.140.761.141.141.141.141.141.141.141.14

40557595

13040557595

130557595

130

108642

108642

10864

108642

1086428642

17777177777777

0.510.510.640.811.020.510.510.640.811.020.510.510.640.81

0.0320.0320.0320.0320.0320.0320.0320.0320.0320.0320.0320.0320.0320.032

1 x 10 + 101 x 8 + 81 x 6 + 61 x 4 + 41 x 2 + 2

2 x 10 + 102 x 8 + 82 x 6 + 62 x 4 + 42 x 2 + 2

2 x 8 + 102 x 6 + 82 x 4 + 62 x 2 + 4

126216316475721195338492733

1107309445657989

2641414141264141414126414141

165235271318377165235271318377235271318377

0.008150.01300.02060.03280.0521

0.008150.01300.02060.03280.05210.01300.02060.03280.0521

SOLIDBBBB

SOLIDBBBBBBBB

102141178225283102141178225283141178225283

3045454545304545454545454545

0.9990.6410.4030.2530.1590.9990.6410.4030.2530.1590.6410.4030.2530.159

269369416476551

272 x 436372 x 607419 x 691479 x 797555 x 931372 x 607409 x 680466 x 784538 x 915

3045454545304545454545454545

40557595

13040557595

130557595

130

108642

108642

10864

108642

1086428642

17777177777777

20.120.125.332.040.320.120.125.332.040.320.120.125.332.0

1.31.31.31.31.31.31.31.31.31.31.31.31.31.3

1 x 10 + 101 x 8 + 81 x 6 + 61 x 4 + 41 x 2 + 2

2 x 10 + 102 x 8 + 82 x 6 + 62 x 4 + 42 x 2 + 2

2 x 8 + 102 x 6 + 82 x 4 + 62 x 2 + 4

85145213319484131227331493744208299441664

2641414141264141414126414141

JACKETTHICKNESS

(mm)

SIZEAWG

DIAMETEROVER

INSULATION(mm)

POLYESTERICTAPE

THICKNESS(mm)

APPROX.TOTAL

WEIGHT(kg/km)

DCRESISTANCE

AT 20°C1

(ohm/km)

CROSSSECTION

(mm2)

CONDUCTORDIAMETER

(mm)

INSULATIONTHICKNESS

(mm)

AMPACITY 2

(A)

STRA

NDS

No.

NEUTRALSIZEAWG STRANDS

No.

CODE DIMENSIONSOVER

JACKET(mm)

NEUTRAL CONDUCTOR

STRANDDIAMETER

(mm)

STRA

NDIN

GCL

ASS

JACKETTHICKNESS

(mils)

SIZEAWG

DIAMETEROVER

INSULATION(mils)

POLYESTERICTAPE

THICKNESS(mils)

APPROX.TOTAL

WEIGHT(pound/1000ft)

DCRESISTANCE

AT 20°C1

(ohm/1000ft)

CROSSSECTION(sq inches)

CONDUCTORDIAMETER

(mils)

INSULATIONTHICKNESS

(mils)

AMPACITY 2

(A)

STRA

NDS

No.

NEUTRALSIZEAWG STRANDS

No.

CODE DIMENSIONSOVER

JACKET(mils)

NEUTRAL CONDUCTOR

STRANDDIAMETER

(mils)

STRA

NDIN

G(m

ils)

Page 26: Low voltage cables

32

Service Entrance Type SER 600VService Entrance Cable Round

Manufacturing Standard: UL 854, NTC 4564. Service Entrance Cables

Service Entrance Type SER 600V (International System Unit)Service Entrance Cable Round

Manufacturing Standard: UL 854, NTC 4564. Service Entrance Cables

Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature, 90°C conductor temperature.

According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

5.966.898.089.57

11.0912.0913.2214.4915.91

5.966.898.089.57

12.0913.2214.4915.91

8.3713.3021.1533.6342.4153.4867.4385.03107.2

8.3713.3021.1533.6353.4867.4385.03107.2

BBBBBBBBBBBBBBBBB

3.594.525.717.208.189.18

10.3111.5813.00

3.594.525.717.209.18

10.3111.5813.00

1.141.141.141.141.401.401.401.401.401.141.141.141.141.401.401.401.40

2.121.34

0.8400.5280.4190.3320.2630.2090.166

2.121.34

0.8400.5280.3320.2630.2090.166

14.7516.7519.3022.5225.8027.9530.3933.1336.1815.6117.7520.4723.9129.7032.3135.2338.49

0.760.760.760.760.760.760.760.760.760.760.760.760.760.760.760.760.76

557595

130150170195225260

557595

130170195225260

---------866421

1/02/0

86421

1/02/03/04/0

8642

1/02/03/04/0

7777

1919191919

7777

19191919

---------77777

191919

0.1000.1000.1000.1000.1000.1000.1000.1000.1000.1000.1000.1000.1000.1000.1000.1000.100

3 x 83 x 63 x 43 x 23 x 1

3 x 1/03 x 2/03 x 3/03 x 4/0

3 x 8 + 83 x 6 + 63 x 4 + 63 x 2 + 4

3 x 1/0 + 23 x 2/0 + 1

3 x 3/0 + 1/03 x 4/0 + 2/0

344501744

112414111740215326693317

424626870

13232055254831673943

---------

3.594.524.525.717.208.189.18

10.31

12.8514.8617.4120.6223.9026.0528.5031.2334.2813.7215.8618.5822.0127.8130.4133.3336.59

235271318377437476521571626235271318377476521571626

0.01300.02060.03280.05210.06570.0829

0.1050.1320.166

0.01300.02060.03280.05210.0829

0.1050.1320.166

BBBBBBBBBBBBBBBBB

141178225283322361406456512141178225283361406456512

4545454555555555554545454555555555

0.6470.4070.2560.1610.1280.101

0.08030.06370.0505

0.6470.4070.2560.1610.101

0.08030.06370.0505

581660760887

10161100119713041424

615699806941

1169127213871515

3030303030303030303030303030303030

557595

130150170195225260

557595

130170195225260

---------866421

1/02/0

86421

1/02/03/04/0

8642

1/02/03/04/0

7777

1919191919

7777

19191919

---------77777

191919

3.93.93.93.93.93.93.93.93.93.93.93.93.93.93.93.93.9

3 x 83 x 63 x 43 x 23 x 1

3 x 1/03 x 2/03 x 3/03 x 4/0

3 x 8 + 83 x 6 + 63 x 4 + 63 x 2 + 4

3 x 1/0 + 23 x 2/0 + 1

3 x 3/0 + 1/03 x 4/0 + 2/0

231336500755948

1170144717942229

285421585889

1381171321282650

---------

141178178225283322361406

506585685812941

1026112212301350

540624731867

1095119713121441

Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature, 90°C conductor temperature. According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

JACKETTHICKNESS

(mm)

SIZEAWG

DIAMETEROVER

INSULATION(mm)

REINFORCEDTAPE

THICKNESS(mm)

APPROX.TOTAL

WEIGHT(Kg/Km)

DCRESISTANCE

AT 20°C1

(ohm/Km)

CROSSSECTION

(mm2)

CONDUCTORDIAMETER

(mm)

INSULATIONTHICKNESS

(mm)

AMPACITY 2

(A)NEUTRAL

SIZEAWG

NEUTRALCONDUCTOR

STRANDSNo.

CODE DIMENSIONSOVER

JACKET(mm)

NEUTRALCONDUCTOR

DIAMETERNo.

ASSEMBLYDIAMETER

(mm)

STRA

NDS

No.

STRA

NDIN

GCL

ASS

JACKETTHICKNESS

(mils)

SIZEAWG

DIAMETEROVER

INSULATION(mils)

REINFORCEDTAPE

THICKNESS(mils)

APPROX.TOTAL

WEIGHT(pound/1000ft)

DCRESISTANCE

AT 20°C1

(ohm/1000ft)

CROSSSECTION(sq inches)

CONDUCTORDIAMETER

(mils)

INSULATIONTHICKNESS

(mils)

AMPACITY 2

(A)NEUTRAL

SIZEAWG

NEUTRALCONDUCTOR

STRANDSNo.

CODE DIMENSIONSOVER

JACKET(mils)

NEUTRALCONDUCTOR

DIAMETERNo.

ASSEMBLYDIAMETER

(mils)

STRA

NDS

No.

STRA

NDIN

G(m

ils)

Page 27: Low voltage cables

33

Description

ARE: one or two XLPE insulated conductors, twisted together, with concentricneutral, PVC filler and PE jacket.

APE: two XLPE insulated conductors, paralleled, with polyester tape, concentricneutral, and PE jacket.

Service Entrance SER: two or three XHHW-2 insulated conductors, twistedtogether with or without bare grounding conductor, reinforced tape and PVCjacket.

Construction

ConductorSoft copper stranded and compressed.InsulationCross Linked Polyethylene (XLPE 90°C).ConfigurationARE: Round.APE: Flat.Binder TapeAPE: Polyester Tape over paralleled conductors.NeutralSoft copper wires applied concentrically around phases with SZ technologywith high coverage over phase conductors.JacketPolyethylene (PE). Rip cord for easy installation.OptionsAluminum conductor. PVC Insulation. Sunlight Resistant PVC Jacket.

Service EntranceType ARE & APEA: Service Entrance R: Round Configuration E: Concentric Neutral ConductorA: Service Entrance P: Flat Configuration E: Concentric Neutral Conductor

Page 28: Low voltage cables

34

Low Smoke Emission PVC Jacket.

Characteristics

Operation TemperatureDry and wet locations 90°C.Operating Voltage600 V.

Uses and Applications

Service Entrance or Drop Cable up to Service Entrance Equipmentand to general breaker.

Standards

CENTELSA ARE and APE Service Entrance Cables are manufacturedunder the following standards:

ASTM B3, NTC-359. Soft copper wires.ASTM B8, NTC-307. Concentric Lay Stranded copper conductors.

Certifications

CENTELSA ARE and APE Service Entrance Cables are certified by:CIDET (Colombia). Cert. No. 00416.

Note: Other configurations and sizes not specified herein are availableupon request.

Page 29: Low voltage cables

35

Service Entrance Type ARE 600V (International System Unit)A: Service Entrance R: Round Configuration E: Concentric Neutral Conductor

Standard: ICEA S-95-658, NTC-ICONTEC 1099-1. Power Cables rated 2000 volts or less for the Distribution of Electrical Energy

Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature, 90°C conductor temperature. According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature, 90°C conductor temperature. According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

Service Entrance Type ARE 600VA: Service Entrance R: Round Configuration E: Concentric Neutral Conductor

Standard: ICEA S-95-658, NTC-ICONTEC 1099-1. Power Cables rated 2000 volts or less for the Distribution of Electrical Energy

JACKETTHICKNESS

(mm)

SIZEAWG

DIAMETEROVER

INSULATION(mm)

STRANDSNo.

APPROX.TOTAL

WEIGHT(kg/km)

DCRESISTANCE

AT 20°C1

(ohm/km)

STRA

NDIN

GCL

ASS CROSS

SECTION(mm2)

CONDUCTORDIAMETER

(mm)

INSULATIONTHICKNESS

(mm)

AMPACITY 2

(A)

STRA

NDS N

o. FILLERTHICKNESS

(mm)

DIAMETEROVER

FILLER(mm)

CODE DIMENSIONSOVER

JACKET(mm)

NEUTRALSIZEAWG

NEUTRAL CONDUCTOR

STRANDDIAMETER

(mm)

3.654.185.966.898.089.573.654.185.966.898.089.57

3.315.268.37

13.3021.1533.63

3.315.268.37

13.3021.1533.63

SOLIDSOLID

BBBB

SOLIDSOLID

BBBB

2.052.593.594.525.717.202.052.593.594.525.717.20

0.760.761.141.141.141.140.760.761.141.141.141.14

5.213.282.101.320.830.525.213.282.101.32

0.8310.523

7.047.589.36

10.2911.7314.36

7.047.589.36

10.2911.7314.36

1.141.141.141.141.141.521.141.141.141.141.141.52

3040557595

1303040557595

130

------

0.500.500.500.500.500.50

1210

8642

1210

8642

117777117777

3.654.185.966.898.089.578.309.37

12.9314.7917.1520.14

172641414141262641414141

1 x 12 + 121 x 10 + 10

1 x 8 + 81 x 6 + 81 x 4 + 61 x 2 + 4

2 x 12 + 122 x 10 + 10

2 x 8 + 82 x 6 + 82 x 4 + 62 x 2 + 4

88126202254382598173243408543794

1200

1210

8864

1210

8864

0.510.510.510.510.640.810.510.510.510.510.640.81

144165235271318377144165235271318377

0.005130.00815

0.01300.02060.03280.0521

0.005130.00815

0.01300.02060.03280.0521

SOLIDSOLID

BBBB

SOLIDSOLID

BBBB

81102141178225283

81102141178225283

303045454545303045454545

1.590.9990.6410.4030.2530.159

1.590.9990.6410.4030.2530.159

277298368405462565277298368405462565

454545454560454545454560

3040557595

1303040557595

130

------

202020202020

1210

8642

1210

8642

117777117777

144165235271318377327369509582675793

172641414141262641414141

1 x 12 + 121 x 10 + 10

1 x 8 + 81 x 6 + 81 x 4 + 61 x 2 + 4

2 x 12 + 122 x 10 + 10

2 x 8 + 82 x 6 + 82 x 4 + 62 x 2 + 4

5985

136171257402117163274365534807

1210

8864

1210

8864

20.120.120.120.125.332.020.120.120.120.125.332.0

JACKETTHICKNESS

(mils)

SIZEAWG

DIAMETEROVER

INSULATION(mils)

STRANDSNo.

APPROX.TOTAL

WEIGHT(pound/1000ft)

DC RESISTANCEAT 20°C1

(ohm/1000ft)STRA

NDIN

G(m

ils)

CROSSSECTION

(sq inches2)

CONDUCTORDIAMETER

(mils)

INSULATIONTHICKNESS

(mils)

AMPACITY 2

(A)

STRA

NDS N

o. FILLERTHICKNESS

(mils)

DIAMETEROVER

FILLER(mils)

CODE DIMENSIONSOVER

JACKET(mils)

NEUTRALSIZEAWG

NEUTRAL CONDUCTOR

STRANDDIAMETER

(mils)

Page 30: Low voltage cables

36

Service Entrance Type APE 600V (International System Unit)A: Service Entrance P: Flat Configuration E: Concentric Neutral Conductor

Standard: ICEA S-95-658, NTC-ICONTEC 1099-1.Power Cables rated 2000 volts or less for the Distribution of Electrical Energy

Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2.No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature, 90°C conductor temperature. According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

4.185.966.898.089.575.966.898.089.57

5.268.37

13.3021.1533.63

8.3713.3021.1533.63

SOLIDBBBBBBBB

2.593.594.525.717.203.594.525.717.20

0.761.141.141.141.141.141.141.141.14

3.282.101.32

0.8310.523

2.101.32

0.8310.523

7.67 x 11.869.45 x 15.42

10.65 x 17.5412.17 x 20.2514.09 x 23.66

9.45 x 15.4210.38 x 17.2811.83 x 19.9113.66 x 23.23

1.141.141.141.141.141.141.141.141.14

40557595

130557595

130

1086428642

177777777

0.0320.0320.0320.0320.0320.0320.0320.0320.032

264141414126414141

2 x 10 + 102 x 8 + 82 x 6 + 62 x 4 + 42 x 2 + 2

2 x 8 + 102 x 6 + 82 x 4 + 62 x 2 + 4

196316467704

1072288420628955

108642

10864

JACKETTHICKNESS

(mm)

SIZEAWG

DIAMETEROVER

INSULATION(mm)

NEUTRALCONDUCTOR

STRANDSNo.

APPROX.TOTAL

WEIGHT(kg/km)

DCRESISTANCE

AT 20°C1

(ohm/km)

STRA

NDIN

GCL

ASS CROSS

SECTION(mm2)

CONDUCTORDIAMETER

(mm)

INSULATIONTHICKNESS

(mm)

AMPACITY 2

(A)

STRA

NDS

No.

POLYESTERICTAPE

THICKNESS(mm)

CODE DIMENSIONSOVER

JACKET(mm)

NEUTRALSIZEAWG

Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature, 90°C conductor temperature. According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

Service Entrance Type APE 600VA: Service Entrance P: Flat Configuration E: Concentric Neutral Conductor

Standard: ICEA S-95-658, NTC-ICONTEC 1099-1.Power Cables rated 2000 volts or less for the Distribution of Electrical Energy

165235271318377235271318377

0.008150.01300.02060.03280.05210.01300.02060.03280.0521

SOLIDBBBBBBBB

102141178225283141178225283

304545454545454545

0.9990.6410.4030.2530.1590.6410.4030.2530.159

302 x 467372 x 607419 x 691479 x 797555 x 931372 x 607409 x 680466 x 784538 x 915

454545454545454545

40557595

130557595

130

1086428642

177777777

1.31.31.31.31.31.31.31.31.3

264141414126414141

2 x 10 + 102 x 8 + 82 x 6 + 62 x 4 + 42 x 2 + 2

2 x 8 + 102 x 6 + 82 x 4 + 62 x 2 + 4

132212314473721193282422642

108642

10864

SIZEAWG

NEUTRALCONDUCTOR

STRANDSNo.

POLYESTERICTAPE

THICKNESS(mils)

CONSTRUCTION

STRA

NDIN

GCL

ASS

STRA

NDS

No. CROSS

SECTION(sq inches2)

CONDUCTORDIAMETER

(mils)

INSULATIONTHICKNESS

(mils)

DIAMETEROVER

INSULATION(mils)

NEUTRALSIZEAWG

DCRESISTANCE

AT 20°C1

(ohm/1000ft)

AMPACITY 2

(A)APPROX.

TOTALWEIGHT

(pound/1000ft)

DIMENSIONSOVER

JACKET(mils)

JACKETTHICKNESS

(mils)

Page 31: Low voltage cables

37

Description

Aluminum conductors PE or XLPE insulated twisted together with a neutralsupporting Messenger in AAC, AAAC or ACSR.

Construction

ConductorConcentrically stranded, compressed 1350-H19 Aluminum. Duplex one phaseconductor, Triplex two phase conductor, Quadruplex three phase conductors.

InsulationCross Linked Polyethylene (XLPE 90°C) or thermoplastic polyethylene (PE75°C).

Neutral supporting messengerAAC All Aluminum Conductor, AAAC All Aluminum Alloy Conductor or ACSRAluminum conductor steel reinforced.

OptionsPhase conductor in AAAC. Neutral covered. Additional conductor for Publiclighting system. Overall Jacket.

Characteristics

Operating Temperature990°C, for XLPE insulation.75°C, for PE insulation.

Operating Voltage600 V.

Neutral SupportedMultiplex Cable

Page 32: Low voltage cables

38

Applications

Duplex: Overhead Secondary Distribution, street lighting, outdoorlighting or temporally installations.

Triplex: Overhead Secondary Distribution, from pole to service entrancederivation.

Quadruplex: Overhead Secondary Distribution Three-phase system,from pole to service entrance derivation.

Standards

CENTELSA MULTIPLEX Cables are manufactured under the followingstandards:ASTM B231, NTC-308. Concentric-Lay-Stranded Aluminum 1350ConductorsICEA S-76-474. Neutral supported power cables assemblies withweather resistant extruded insulation rated 600 volts.

Certifications

CENTELSA MULTIPLEX Cables are certified by:CIDET (Colombia). Certificate No. 01336 ICEA S-76-474.

Note: Other configurations and sizes not specified herein are availableupon request.

Page 33: Low voltage cables

39

Neutral Supported Duplex 600V (International System Unit)

Manufacturing Standard: ICEA S-76-474. Neutral supported power cables assemblieswith weather resistant extruded insulation rated 600 volts.

Notes: 1. DC resistance calculated based on a 28,172 ohm-mm2/km resistivity for aluminum.2. 40°C Ambient temperature, 610 mm/seg wind speed, at sea level at 60 Hz.3. 75°C conductor temperature.4. 90°C conductor temperature.5. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

STRANDSNo.

CODE DIAMETEROVER

INSULATION(mm)

SIZEAWG /kcmil

APPROX.TOTAL

WEIGHT(kg/km)

DCRESISTANCE

AT 20°C1

(ohm/km)

STRANDINGCLASS

CROSSSECTION

(mm2)

CONDUCTORDIAMETER

(mm)

INSULATIONTHICKNESS

(mm)

AMPACITY 2

(A)3STRANDS

No. TYPE

AMPACITY 2

(A)4SIZE

AWG /kcmil

SELF SUPPORTING NEUTRAL

TENSILESTRENGTH

(kg)

6.506.907.578.099.58

12.346.506.907.578.099.58

12.346.506.907.578.099.58

12.34

13.3013.3021.1521.1533.6353.4813.3013.3021.1521.1533.6353.4813.3013.3021.1521.1533.6353.48

SOLIDB

SOLIDBBB

SOLIDB

SOLIDBBB

SOLIDB

SOLIDBBB

4.124.525.195.717.209.184.124.525.195.717.209.184.124.525.195.717.209.18

1.141.141.141.141.141.521.141.141.141.141.141.521.141.141.141.141.141.52

2.122.161.331.36

0.8540.537

2.122.161.331.36

0.8540.537

2.122.161.331.36

0.8540.537

95100142149227360112117170177271429101105152159242384

777777

6/16/16/16/16/16/1

777777

70709090

120160

70709090

120160

70709090

120160

AAC

ACSR

AAAC

PEKINGESECOLLIE

DACHSHUNDSPANIEL

DOBERMANMALEMUTE

SETTERSHEPHERD

ESKIMOTERRIER

CHOWBULL

CHIHUAHUAVIZSLA

HARRIERWHIPPET

SCHNAUZERHEELER

17177

1917177

1917177

19

8585

115115150205

8585

115115150205

8585

115115150205

66442

1/066442

1/030.5830.5848.6948.6977.47123.3

66442

1/066442

1/066442

1/0

256256400400613903540540845845

12941986

502502799799

12721939

Page 34: Low voltage cables

40

256272298318377486256272298318377486256272298318377486

0.02060.02060.03280.03280.05210.08290.02060.02060.03280.03280.05210.08290.02060.02060.03280.03280.05210.0829

SOLIDB

SOLIDBBB

SOLIDB

SOLIDBBB

SOLIDB

SOLIDBBB

162178204225283361162178204225283361162178204225283361

454545454560454545454560454545454560

0.6460.6580.4060.4140.2600.1640.6460.6580.4060.4140.2600.1640.6460.6580.4060.4140.2600.164

646796

100153242

7578

114119182289

6871

102107163258

777777

6/16/16/16/16/16/1

777777

70709090

120160

70709090

120160

70709090

120160

AAC

ACSR

AAAC

PEKINGESECOLLIE

DACHSHUNDSPANIEL

DOBERMANMALEMUTE

SETTERSHEPHERD

ESKIMOTERRIER

CHOWBULL

CHIHUAHUAVIZSLA

HARRIERWHIPPET

SCHNAUZERHEELER

17177

1917177

1917177

19

8585

115115150205

8585

115115150205

8585

115115150205

66442

1/066442

1/030.5830.5848.6948.6977.47123.3

66442

1/066442

1/066442

1/0

564564882882

13511991119011901863186328534378110711071761176128044275

Notes: 1. DC resistance calculated based on a 16,946 ohm-mm2/km resistivity for aluminum.2. 40°C Ambient temperature, 610 mm/seg wind speed, at sea level at 60 Hz.3. 75°C conductor temperature.4. 90°C conductor temperature.5. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

Neutral Supported Duplex 600V

Manufacturing Standard: ICEA S-76-474. Neutral supported power cablesassemblies with weather resistant extruded insulation rated 600 volts.

6.506.907.578.099.58

12.34

13.3013.3021.1521.1533.6353.48

SOLIDB

SOLIDBBB

4.124.525.195.717.209.18

1.141.141.141.141.141.52

2.122.161.331.36

0.8540.537

153162226240361582

777777

70709090

120160

AAC

HAIOTISPATELLAFUSUS

OYSTERCLAM

MUREX

171777

8585

115115150205

66442

1/0

66442

1/0

256256400400613903

Neutral Supported Triplex 600V (International System Unit)

Manufacturing Standard: ICEA S-76-474. Neutral supported power cablesassemblies with weather resistant extruded insulation rated 600 volts.

Continued on page 41

STRANDSNo.

CODE DIAMETEROVER

INSULATION(mils)

SIZEAWG /kcmil

APPROX.TOTAL

WEIGHT(pound/1000ft)

DCRESISTANCE

AT 20°C1

(ohm/1000ft)

STRANDING(mils)

CROSSSECTION(sq inches)

CONDUCTORDIAMETER

(mils)

INSULATIONTHICKNESS

(mils)

AMPACITY 2

(A)3STRANDS

No. TYPE

AMPACITY 2

(A)4SIZE

AWG /kcmil

SELF SUPPORTING NEUTRAL

TENSILESTRENGTH

(pound)

STRANDSNo.

CODE DIAMETEROVER

INSULATION(mm)

SIZEAWG /kcmil

APPROX.TOTAL

WEIGHT(Kg/Km)

DCRESISTANCE

AT 20°C1

(ohm/Km)

STRANDINGCLASS

CROSSSECTION

(mm²)

CONDUCTORDIAMETER

(mm)

INSULATIONTHICKNESS

(mm)

AMPACITY 2

(A)3STRANDS

No. TYPE

AMPACITY 2

(A)4SIZE

AWG /kcmil

SELF SUPPORTING NEUTRAL

TENSILESTRENGTH

(Kg)

Page 35: Low voltage cables

41

Notes: 1. DC resistance calculated based on a 28,172 ohm-mm2/km resistivity for aluminum.2. 40°C Ambient temperature, 610 mm/seg wind speed, at sea level at 60 Hz.3. 75°C conductor temperature.4. 90°C conductor temperature.5. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

12.3413.4713.4714.7416.1620.57

6.506.907.578.099.58

12.3412.3413.4713.4714.7416.1620.57

7.578.099.58

12.3412.3413.4713.4714.7416.1620.57

6.506.907.578.099.58

12.3412.3413.4713.4714.7416.16

7.578.099.58

12.3412.3413.4713.4714.7416.16

53.4867.4367.4385.03107.2170.513.3013.3021.1521.1533.6353.4853.4867.4367.4385.03107.2170.521.1521.1533.6353.4853.4867.4367.4385.03107.2170.513.3013.3021.1521.1533.6353.4853.4867.4367.4385.03107.221.1521.1533.6353.4853.4867.4367.4385.03107.2

BBBBBB

SOLIDB

SOLIDBBBBBBBBB

SOLIDBBBBBBBBB

SOLIDB

SOLIDBBBBBBBB

SOLIDBBBBBBBB

9.1810.3110.3111.5813.0016.39

4.124.525.195.717.209.189.18

10.3110.3111.5813.0016.39

5.195.717.209.189.18

10.3110.3111.5813.0016.39

4.124.525.195.717.209.189.18

10.3110.3111.5813.00

5.195.717.209.189.18

10.3110.3111.5813.00

1.521.521.521.521.522.031.141.141.141.141.141.521.521.521.521.521.522.031.141.141.141.521.521.521.521.521.522.031.141.141.141.141.141.521.521.521.521.521.521.141.141.141.521.521.521.521.521.52

0.5370.4260.4260.3380.2680.169

2.122.161.331.36

0.8540.5370.5370.4260.4260.3380.2680.169

1.331.36

0.8540.5370.5370.4260.4260.3380.2680.169

2.122.161.331.36

0.8540.5370.5370.4260.4260.3380.268

1.331.36

0.8540.5370.5370.4260.4260.3380.268

571715702865

10691713

170179254267404651640803789975

12081788

221235353570559701687847

10461676

158168235249376606595746732903

1117210224335541530664651801989

777

1919196/16/16/16/16/16/16/16/16/16/16/1

18/16/16/16/16/16/16/16/16/16/16/1

77777777777777777777

160185185215245325

70709090

120160160185185215245325

9090

120160160185185215245325

70709090

120160160185185215245

9090

120160160185185215245

AAC

ACSR

ACSRREDUCED

SIZE

AAAC

AAACREDUCED

SIZE

PURPURANASSA

TROPHONMELITA

PORTUNUSNANNYNOSE

PALUDINAVOLUTAWHELK

PERIWINKLECONCH

NERITINACENIA

RUNCINATRITONMURSIAZUZARALIMPET

SCALLOPSTROMBUS

COCKLEJANTHINARANELLA

CAVOLINIACLIOAEGA

CERAPUSCOWRYMINEXHIPPA

PRAWNBARNACLES

SHRIMPGAMMARUS

LEDADUNGENESE

CYCLOPSFLUSTRA

LEPASARTEMIA

CRABSOLASTERSANDCRABECHINUSCRAYFISH

SIPHOFULGAR

ARCA

197

19191919

171777

197

19191919

1777

197

19191919

171777

197

191919

1777

197

191919

205235235275315420

8585

115115150205205235235275315420115115150205205235235275315420

8585

115115150205205235235275315115115150205205235235275315

1/02/02/03/04/0

336.466442

1/01/02/02/03/04/0

336.46642211

1/02/04/0

30.5830.5848.6948.6977.47123.3123.3155.4155.4195.7246.9

30.630.648.777.577.597.697.6

123.3155.4

1/02/02/03/04/0

336.466442

1/01/02/02/03/04/0

336.4442

1/01/02/02/03/04/0

336.466442

1/01/02/02/03/04/0

442

1/01/02/02/03/04/0

90311381138150118232786

540540845845

12941986198624032403300037843937

540540845

1294129416161616198624033784

502502799799

1272193919392444244430773882

502502799

127212721603160319392444

Neutral Supported Triplex 600V (International System Unit)

Continued from page 40

STRANDSNo.

CODE DIAMETEROVER

INSULATION(mm)

SIZEAWG /kcmil

APPROX.TOTAL

WEIGHT(Kg/Km)

DCRESISTANCE

AT 20°C1

(ohm/Km)

STRANDINGCLASS

CROSSSECTION

(mm²)

CONDUCTORDIAMETER

(mm)

INSULATIONTHICKNESS

(mm)

AMPACITY 2

(A)3STRANDS

No. TYPE

AMPACITY 2

(A)4SIZE

AWG /kcmil

SELF SUPPORTING NEUTRAL

TENSILESTRENGTH

(Kg)

Page 36: Low voltage cables

42

256272298318377486486530530580636810256272298318377486486530530580636810298318377486486530530580636810256272298318377486486530530580636298318377486

0.02060.02060.03280.03280.05210.08290.08290.10450.10450.13180.16620.26420.02060.02060.03280.03280.05210.08290.08290.10450.10450.13180.16620.26420.03280.03280.05210.08290.08290.10450.10450.13180.16620.26420.02060.02060.03280.03280.05210.08290.08290.10450.10450.13180.16620.03280.03280.05210.0829

SOLIDB

SOLIDBBBBBBBBB

SOLIDB

SOLIDBBBBBBBBB

SOLIDBBBBBBBBB

SOLIDB

SOLIDBBBBBBBB

SOLIDBBB

162178204225283361361406406456512645162178204225283361361406406456512645204225283361361406406456512645162178204225283361361406406456512204225283361

45454545456060606060608045454545456060606060608045454560606060606080454545454560606060606045454560

0.6460.6580.4060.4140.2600.1640.1640.1300.1300.103

0.08170.0514

0.6460.6580.4060.4140.2600.1640.1640.1300.1300.103

0.08170.0514

0.4060.4140.2600.1640.1640.1300.1300.103

0.08170.0514

0.6460.6580.4060.4140.2600.1640.1640.1300.1300.103

0.08170.4060.4140.2600.164

103109152161242391384481472581718

1151114120170180272438430540530655812

1202149158237383376471462569703

1126107113158168252407400501492607751141150225364

777777777

1919196/16/16/16/16/16/16/16/16/16/16/1

18/16/16/16/16/16/16/16/16/16/16/1

777777777777777

70709090

120160160185185215245325

70709090

120160160185185215245325

9090

120160160185185215245325

70709090

120160160185185215245

9090

120160

AAC

ACSR

ACSRREDUCED

SIZE

AAAC

AAACREDUCED

SIZE

HAIOTISPATELLAFUSUS

OYSTERCLAM

MUREXPURPURA

NASSATROPHON

MELITAPORTUNUS

NANNYNOSEPALUDINAVOLUTAWHELK

PERIWINKLECONCH

NERITINACENIA

RUNCINATRITONMURSIAZUZARALIMPET

SCALLOPSTROMBUS

COCKLEJANTHINARANELLA

CAVOLINIACLIOAEGA

CERAPUSCOWRYMINEXHIPPA

PRAWNBARNACLES

SHRIMPGAMMARUS

LEDADUNGENESE

CYCLOPSFLUSTRA

LEPASARTEMIA

CRABSOLASTERSANDCRAB

171777

197

19191919

171777

197

19191919

1777

197

19191919

171777

197

191919

1777

8585

115115150205205235235275315420

8585

115115150205205235235275315420115115150205205235235275315420

8585

115115150205205235235275315115115150205

66442

1/01/02/02/03/04/0

336.466442

1/01/02/02/03/04/0

336.46642211

1/02/04/0

30.5830.5848.6948.6977.47123.3123.3155.4155.4195.7246.9

30.630.648.777.5

66442

1/01/02/02/03/04/0

336.466442

1/01/02/02/03/04/0

336.4442

1/01/02/02/03/04/0

336.466442

1/01/02/02/03/04/0

442

1/0

564564882882

135119911991250925093309401961421190119018631863285343784378529852986614834286791190119018632853285335633563437852988342110711071761176128044275427553885388678485581107110717612804

Continued on page 43

Neutral Supported Triplex 600V

Manufacturing Standard: ICEA S-76-474. Neutral supported power cablesassemblies with weather resistant extruded insulation rated 600 volts.

STRANDSNo.

CODE DIAMETEROVER

INSULATION(mils)

SIZEAWG /kcmil

APPROX.TOTAL

WEIGHT(pound/1000ft)

DCRESISTANCE

AT 20°C1

(ohm/1000ft)

STRANDING(mils)

CROSSSECTION(sq inches)

CONDUCTORDIAMETER

(mils)

INSULATIONTHICKNESS

(mils)

AMPACITY 2

(A)3STRANDS

No. TYPE

AMPACITY 2

(A)4SIZE

AWG /kcmil

SELF SUPPORTING NEUTRAL

TENSILESTRENGTH

(pound)

Page 37: Low voltage cables

43

486530530580636

0.08290.10450.10450.13180.1662

BBBBB

361406406456512

6060606060

0.1640.1300.1300.103

0.0817

356447437538664

77777

160185185215245

AAACREDUCED

SIZE

ECHINUSCRAYFISH

SIPHOFULGAR

ARCA

197

191919

205235235275315

77.597.697.6

123.3155.4

1/02/02/03/04/0

28043534353442755388

7.578.099.58

12.3413.4714.7416.1620.57

6.506.907.578.099.58

12.3413.4714.7416.1620.57

6.506.907.578.099.58

12.3413.4714.7416.16

21.1521.1533.6353.4867.4385.03107.2170.513.3013.3021.1521.1533.6353.4867.4385.03107.2170.513.3013.3021.1521.1533.6353.4867.4385.03107.2

SOLIDBBBBBBB

SOLIDB

SOLIDBBBBBBB

SOLIDB

SOLIDBBBBBB

5.195.717.209.18

10.3111.5813.0016.39

4.124.525.195.717.209.18

10.3111.5813.0016.39

4.124.525.195.717.209.18

10.3111.5813.00

1.141.141.141.521.521.521.522.031.141.141.141.141.141.521.521.521.522.031.141.141.141.141.141.521.521.521.52

1.331.36

0.8540.5370.4260.3380.2680.169

2.122.161.331.36

0.8540.5370.4260.3380.2680.169

2.122.161.331.36

0.8540.5370.4260.3380.268

310330494781958

117914542332

228242337358538851

1046128915932407

216230319340509806989

12171502

77777

1919196/16/16/16/16/16/16/16/16/1

18/1777777777

8080

105140160185210280

60608080

105140160185210280

60608080

105140160185210

AAC

ACSR

AAAC

CLYDESDALEPINTO

MUSTANGCRIOLLO

PERCHERONHANOVERIANOLDENBURGLIPPIZANER

MOROCHUCACHOLA

MORGANHACKNEYPALOMINOCOSTENAGRULLOSUFFOLK

APPALOOSABRONCO

BAYFRENCH-COACHGERMAN-COACH

ARABIANBELGIAN

SHETLANDTHOROUGHBRED

TROTTERWALKING

177

1919191919

17177

1919191919

17177

19191919

100100135180205235275370

7575

100100135180205235275370

7575

100100135180205235275

442

1/02/03/04/0

336.466442

1/02/03/04/0

336.430.5830.5848.6948.6977.47123.3155.4195.7246.9

442

1/02/03/04/0

336.466442

1/02/03/04/0

336.466442

1/02/03/04/0

400400613903

1138150118232786

540540845845

129419862403300037843937

502502799799

12721939244430773882

Neutral Supported Triplex 600V

Continued from page 42

STRANDSNo.

CODE DIAMETEROVER

INSULATION(mils)

SIZEAWG /kcmil

APPROX.TOTAL

WEIGHT(pound/1000ft)

DCRESISTANCE

AT 20°C1

(ohm/1000ft)

STRANDING(mils)

CROSSSECTION(sq inches)

CONDUCTORDIAMETER

(mils)

INSULATIONTHICKNESS

(mils)

AMPACITY 2

(A)3STRANDS

No. TYPE

AMPACITY 2

(A)4SIZE

AWG /kcmil

SELF SUPPORTING NEUTRAL

TENSILESTRENGTH

(pound)

Notes: 1. DC resistance calculated based on a 16,946 ohm-mm2/km resistivity for aluminum.2. 40°C Ambient temperature, 610 mm/seg wind speed, at sea level at 60 Hz.3. 75°C conductor temperature.4. 90°C conductor temperature.5. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

Neutral Supported Quadruplex 600V (International System Unit)

Manufacturing Standard: ICEA S-76-474. Neutral supported power cablesassemblies with weather resistant extruded insulation rated 600 volts.

STRANDSNo.

CODE DIAMETEROVER

INSULATION(mm)

SIZEAWG /kcmil

APPROX.TOTAL

WEIGHT(Kg/Km)

DCRESISTANCE

AT 20°C1

(ohm/Km)

STRANDINGCLASS

CROSSSECTION

(mm²)

CONDUCTORDIAMETER

(mm)

INSULATIONTHICKNESS

(mm)

AMPACITY 2

(A)3STRANDS

No. TYPE

AMPACITY 2

(A)4SIZE

AWG /kcmil

SELF SUPPORTING NEUTRAL

TENSILESTRENGTH

(Kg)

Notes: 1. DC resistance calculated based on a 28,172 ohm-mm2/km resistivity for aluminum.2. 40°C Ambient temperature, 610 mm/seg wind speed, at sea level at 60 Hz.3. 75°C conductor temperature.4. 90°C conductor temperature.5. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

Page 38: Low voltage cables

44

298318377486530580636810256272298318377486530580636810256272298318377486530580636

0.03280.03280.05210.0829

0.1050.1320.1660.264

0.02060.02060.03280.03280.05210.0829

0.1050.1320.1660.264

0.02060.02060.03280.03280.05210.0829

0.1050.1320.166

SOLIDBBBBBBB

SOLIDB

SOLIDBBBBBBB

SOLIDB

SOLIDBBBBBB

204225283361406456512645162178204225283361406456512645162178204225283361406456512

454545606060608045454545456060606080454545454560606060

0.4060.4140.2600.1640.1300.103

0.08170.0514

0.6460.6580.4060.4140.2600.1640.1300.103

0.08170.0514

0.6460.6580.4060.4140.2600.1640.1300.103

0.0817

208222332525644792977

1568153162227240361572703866

10711618

145155214228342541665818

1010

77777

1919196/16/16/16/16/16/16/16/16/1

18/1777777777

8080

105140160185210280

60608080

105140160185210280

60608080

105140160185210

AAC

ACSR

AAAC

CLYDESDALEPINTO

MUSTANGCRIOLLO

PERCHERONHANOVERIANOLDENBURGLIPPIZANER

MOROCHUCACHOLA

MORGANHACKNEYPALOMINOCOSTENAGRULLOSUFFOLK

APPALOOSABRONCO

BAYFRENCH-COACHGERMAN-COACH

ARABIANBELGIAN

SHETLANDTHOROUGHBRED

TROTTERWALKING

177

1919191919

17177

1919191919

17177

19191919

100100135180205235275370

7575

100100135180205235275370

7575

100100135180205235275

442

1/02/03/04/0

336.466442

1/02/03/04/0

336.430.5830.5848.6948.6977.47123.3155.4195.7246.9

442

1/02/03/04/0

336.466442

1/02/03/04/0

336.466442

1/02/03/04/0

882882

1351199125093309401961421190119018631863285343785298661483428679110711071761176128044275538867848558

Notes: 1. DC resistance calculated based on a 16,946 ohm-mm2/km resistivity for aluminum.2. 40°C Ambient temperature, 610 mm/seg wind speed, at sea level at 60 Hz.3. 75°C conductor temperature.4. 90°C conductor temperature.5. Data herein indicated are approximated and are subject to normal manuracturing tolerances.

Neutral Supported Quadruplex 600V

Manufacturing Standard: ICEA S-76-474. Neutral supported power cablesassemblies with weather resistant extruded insulation rated 600 volts.

STRANDSNo.

CODE DIAMETEROVER

INSULATION(mils)

SIZEAWG /kcmil

APPROX.TOTAL

WEIGHT(pound/1000ft)

DCRESISTANCE

AT 20°C1

(ohm/1000ft)

STRANDING(mils)

CROSSSECTION(sq inches)

CONDUCTORDIAMETER

(mils)

INSULATIONTHICKNESS

(mils)

AMPACITY 2

(A)3STRANDS

No. TYPE

AMPACITY 2

(A)4SIZE

AWG /kcmil

SELF SUPPORTING NEUTRAL

TENSILESTRENGTH

(pound)