lng-ld-009h1 sur09134 sk splendor 050809
TRANSCRIPT
D A T A E N T R Y F O R M
VESSEL NAME : SK SPLENDOR Program Version Number
TERMINAL : OMAN LNG LNG-LD-009H1 (07-AUG-09)
PORT : SUR, OMAN
DATE REPORT ISSUED : 5-Aug-2009
INTERTEK FILE NUMBER : SUR/09/134
CUSTOMER NAME : OMAN LNG
ADDRESS #1 : P.O. BOX 560
ADDRESS #2 : MUSCAT 116
ADDRESS #3 : SULTANATE OF OMAN
ADDRESS #4 :
ADDRESS #5 :
CONTACT NAME #1 : ACCOUNTS PAYABLE - NGF / 23
CONTACT NAME #2 : ATIQ AHMED
CONTACT NAME #3 :
CUSTOMER REFERENCE #1 : OF039/09-SL100-KG
CUSTOMER REFERENCE #2 :
SPA SUPPLIED BY : OMAN LNG / KOGAS CORPORATION
R E P O R T S E T U P & G U I D E L I N E S
1SELECT TYPE OF REPORT OF QUANTITY
SELECT TYPE OF REPORT OF QUANTITY ( STANDARD OR QUANTITY SPLIT).
0SELECT TO DISPLAY OR HIDE THE REPORT OF GAS-UP
IF GAS-UP IS REQUIRED, SELECT WHICH CALCUALTION METHOD IS TO BE USED.
0SELECT TO DISPLAY OR HIDE THE REPORT OF COOL DOWN
14SELECT WHICH CONTRACT (SPA) IS TO BE USED FOR CALCULATIONS
YESSELECT TO DISPLAY OR HIDE THE SECONDARY CUSTODY TRANSFER MEASUREMENTS.
0SELECT TO DISPLAY HOW MANY SNAPSHOT MEASUREMENT PAGES ARE NEEDED.
CHOSE FROM ZERO TO FOUR ADDITIONAL CTMS "SNAPSHOT" MEASUREMENT PAGES.
FOR INTERTEK USE ONLY
DO NOT ISSUE THIS
PAGE TO CUSTOMERS
IN ORDER FOR THIS PROGRAM TO WORK PROPERLY, MACROS MUST BE ENABLED
Report of
Quantity
Report of Gas Up
Report of
Cool DownIF COOL DOWN IS REQUIRED, SELECT WHICH COOL DOWN CALCULATION METHOD IS TO BE USED.
Contract Used
( SPA )ALL PAGES WILL AUTOMATICALLY CHANGE TO THE VALUES OF THE APPROPRIATE CALCULATION METHOD AS DESCRIBED IN THE RELEVANT CONTRACT (SPA)
Secondary Custody Transfer
Measurement
SECONDARY CUSTODY TRANSFER PAGE RECORDS AND CALCULATES THE VOLUMES OF THE SECONDARY GAUGING SYSTEM FOR OPENING & CLOSING AND COMPARES THE VOLUMES TO THE PRIMARY SYSTEMS.
CTMS "Snapshot"
Measurement
Page(s)
1SELECT TO WHICH OPERATIONAL CHECKLIST TO DISPLAY
SELECT THE APPROPRIATE CHECKLIST TO BE DISPLAYED AND REPORTED.
0SELECT TO DISPLAY OR HIDE THE VERIFICATION OF GC PAGE
NONESELECT TO DISPLAY OR HIDE THE BUNKER REPORTS
0SELECT TO DISPLAY HOW MANY LETTER OF PROTEST ARE NEEDED.
CHOSE FROM ZERO TO FOUR LETTERS OF PROTEST.
0SELECT TO DISPLAY OR HIDE CLIENT SPECIFIC REPORTS
SELECT IF ANY ADDITIONAL CLIENT SPECIFIC REPORT IS NEEDED OR NOT.
NoneSELECT TO IDENTIFY REVISED REPORT
SELECT IF REPORT WAS REVISED AND WHICH REVISION NUMBER IS TO BE ISSUED
NOSELECT TO PLACE PAGE NUMBERS ON BOTTOM OF REPORT PAGES
Operational Checklist
Verification of GC
IF NO VERIFICATION OF GC IS REQUIRED, OBTAIN A COPY OF THE TERMINAL'S VERIFICATION RECORDS BEFORE & AFTER. OBTAIN COPIES OF THE CERTIFICATIONS FOR THE SPAN GAS AND LAST CALIBRATION OF THE GC.
Bunker Reports IF NO BUNKER REPORTS ARE REQUIRED, OBTAIN A COPY OF THE VESSEL'S BUNKER
REPORT BEFORE & AFTER FROM THE CHIEF ENGINEER.
Letter(s) of
Protest
Client Specific
Reports
Report Revision
Number
Page Numbers Required
SELECT IF PAGE NUMBERS ARE NEEDED AT THE BOTTOM OF THE PAGES WITHIN THE REPORT
5-Aug-2009
OMAN LNGP.O. BOX 560MUSCAT 116SULTANATE OF OMAN
ATTN : ACCOUNTS PAYABLE - NGF / 23ATTN : ATIQ AHMED
REFERENCE : FOR SERVICES RENDERED TO ATTEND THE LOADING OF L.N.G.ON BOARD THE VESSEL "SK SPLENDOR" FOR THE ENERGYDELIVERED AT OMAN LNG / SUR, OMAN ON4-Aug-2009 TO 5-Aug-2009
OUR REFERENCE : SUR/09/134YOUR REFERENCE : OF039/09-SL100-KG
DEAR SIR / MADAM:
ENCLOSED FOR YOUR REVIEW IS OUR REPORT COVERING THE VESSEL "SK SPLENDOR" AT THE ABOVE LOCATION ON THE DATESINDICATED.
THE ENERGY VALUES WERE CALCULATED AS PER THE SPA SUPPLIED BYOMAN LNG / KOGAS CORPORATION
SHOULD YOU HAVE ANY QUESTIONS REGARDING THIS REPORTPLEASE DO NOT HESITATE TO CONTACT US AT YOUR CONVENIENCE.
WE THANK YOU FOR REQUESTING OUR SERVICES.
RESPECTFULLY FOR,INTERTEK CALEB BRETT
PONNAPPA CHOKIRAMANAGER
INTERTEK OIL CHEMICAL & AGRI
P.O. BOX 39, PC 114
MINA AL FAHAL
SULTANATE OF OMAN
TELEPHONE +968 (2) 448 0229
LNG-LD-009H1 (07-AUG-09) - 14
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F L O A D I N G
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. LAST PORT INFORMATION
LAST PORT TERMINAL / PORT : KOGAS / INCHEON
LAST PORT C.C.T. QUANTITY : 1,553.335 CUBIC METERS
LAST PORT C.C.T. INSPECTION DATE : 20-Jul-2009 TIME : 15:48
2. OPENING CUSTODY TRANSFER INFORMATION
OPENING CUSTODY TRANSFER VOLUME : 404.978 CUBIC METERS
OPENING CUSTODY TRANSFER TEMPERATURES : -146.2 °C - Liquid -128.5 °C - Vapor
OPENING CUSTODY TRANSFER TANK PRESSURE : 1166 mbar
OPENING CUSTODY TRANSFER INSPECTION DATE : 4-Aug-2009 TIME : 10:28
3. CLOSING CUSTODY TRANSFER INFORMATION
CLOSING CUSTODY TRANSFER VOLUME : 136,292.944 CUBIC METERS
CLOSING CUSTODY TRANSFER TEMPERATURE : -160.2 °C - Liquid -152.0 °C - Vapor
CLOSING CUSTODY TRANSFER TANK PRESSURE : 1101.5 mbar
CLOSING CUSTODY TRANSFER INSPECTION DATE : 5-Aug-2009 TIME : 04:17
4. VESSEL COOL DOWN WAS NOT REQUIRED
COOL DOWN TRANSFER VOLUME : --- CUBIC METERS
COOL DOWN TRANSFER TEMPERATURE : --- °C - Liquid --- °C - Vapor
COOL DOWN TRANSFER TANK PRESSURE : --- mbar
COOL DOWN TRANSFER INSPECTION DATE : --- TIME : ---
5. LOAD INFORMATION
** VESSEL DELIVERED VOLUME (LIQUID) AT -160.2 °C : 135,888.000 CUBIC METERS
** VESSEL DELIVERED VOLUME (LIQUID) AT -160.2 °C : 135,888,000 LITERS
** VESSEL DELIVERED VOLUME (LIQUID) AT -160.0 °C : 135,971.000 CUBIC METERS
VESSEL DELIVERED VOLUME (GAS) : 2,876.574 MILLION CUBIC FEET @ S.R.C.
VESSEL DELIVERED VOLUME (GAS) : 81,455.497 1000 CUBIC METERS @ S.R.C.
** LIQUID TEMPERATURE AFTER LOADING : -160.2 °C
** VAPOR TEMPERATURE BEFORE LOADING : -128.5 °C
** TANK PRESSURE BEFORE LOADING : 1166 mbar
** LNG DENSITY AT -160.2 °C : 459.080
** LNG DENSITY AT -160.0 °C 458.800
MASS DELIVERED : 62,172.077 METRIC TONS
** GROSS HEATING VALUE (MASS) : 54.4361 MJ / kg
** GROSS HEATING VALUE (VOLUME) : 1115 BTU / SCF
** WOBBE INDEX : 1411 BTU / SCF
** INDICATED VALUES ARE ROUNDED IN ACCORDANCE WITH SPECIFIC S.P.A. REQUIREMENTS
6. ADDITIONAL INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
LNG-LD-009H1 (07-AUG-09) - 14
kg / m3
kg / m4
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F Q U A N T I T Y
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. CUSTODY TRANSFER DENSITY
LNG DENSITY AT -160.2 °C 459.080
2. CUSTODY TRANSFER VOLUME & MASS
CUBIC METERS KILOGRAMS METRIC TONS
QUANTITY RECEIVED BY VESSEL 135,888.000 62,172,077 62,172.077
QUANTITY CONSUMED BY VESSEL 0.000 0 0.000
QUANTITY USED FOR GAS-UP 0.000 0 0.000
QUANTITY USED FOR COOL DOWN 0.000 0 0.000
ADJUSTED QUANTITY DELIVERED 135,888.000 62,172,077 62,172.077
3. CUSTODY TRANSFER ENERGY
MEGAJOULES MMBTU KILOWATT HOURS
GROSS QUANTITY DELIVERED 3,395,719,322 3,218,508 943,255,367
QUANTITY DISPLACED 11,743,022 11,130 3,261,951
QUANTITY DELIVERED 3,383,978,343 3,207,380 939,993,417
QUANTITY CONSUMED BY VESSEL 0 0 0
QUANTITY USED FOR GAS-UP 0 0 0
QUANTITY USED FOR COOL DOWN 0 0 0
ADJUSTED QUANTITY DELIVERED 3,383,978,343 3,207,380 939,993,417
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F.
4. ADDITIONAL INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
ROQ 1 - Standard LNG-LD-009H1 (07-AUG-09) - 14
kg / m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F Q U A N T I T Y
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. CUSTODY TRANSFER DENSITY
LNG DENSITY AT -160.2 °C 459.080
2. CUSTODY TRANSFER VOLUME & MASS
CUBIC METERS KILOGRAMS METRIC TONS
QUANTITY RECEIVED BY VESSEL 135,888.000 62,172,077 62,172.077
QUANTITY CONSUMED BY VESSEL 0.000 0 0.000
QUANTITY USED FOR GAS-UP 0.000 0 0.000
QUANTITY USED FOR COOL DOWN 0.000 0 0.000
ADJUSTED QUANTITY DELIVERED 135,888.000 62,172,077 62,172.077
3. CUSTODY TRANSFER ENERGY
MEGAJOULES MMBTU KILOWATT HOURS
GROSS QUANTITY DELIVERED 3,395,719,322 3,218,508 943,255,367
QUANTITY DISPLACED 11,743,022 11,130 3,261,951
QUANTITY DELIVERED 3,383,978,343 3,207,380 939,993,417
QUANTITY CONSUMED BY VESSEL 0 0 0
QUANTITY USED FOR GAS-UP 0 0 0
QUANTITY USED FOR COOL DOWN 0 0 0
ADJUSTED QUANTITY DELIVERED 3,383,978,343 3,207,380 939,993,417
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F.
4. QUANTITY SPLITS
CARGO NUMBER CUBIC METERS METRIC TONS MEGAJOULES MMBTU KILOWATT HOURS
1 T-54674-Y03 63,888.000 29,230.319 1,590,983,813 1,507,956 441,939,681
2 T-54674-Y04 42,000.000 19,216.025 1,045,913,476 991,331 290,531,346
3 T-54674-Y05 10,000.000 4,575.244 249,027,018 236,031 69,174,130
4 T-54674-Y06 20,000.000 9,150.488 498,054,036 472,062 138,348,260
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
ROQ 2 - Quantity Split LNG-LD-009H1 (07-AUG-09) - 14
kg / m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F A N A L Y S I S
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. DESCRIPTION
SAMPLE DESIGNATED AS : LIQUEFIED NATURAL GAS
SAMPLE TESTED BY : TERMINAL IN-LINE GC - VERIFIED PRIOR TO LOADING
SAMPLE REPRESENTING : COMPOSITE CONTINUOUS SAMPLING
2. ANALYSIS
TEST METHODLIQUID
COMPOSITION
METHANE GPA 2261 90.2400 % mol
ETHANE GPA 2261 5.9500 % mol
PROPANE GPA 2261 2.2400 % mol
ISO BUTANE GPA 2261 0.6900 % mol
N-BUTANE GPA 2261 0.5800 % mol
ISO PENTANE GPA 2261 0.0200 % mol
N-PENTANE GPA 2261 0.0000 % mol
N-HEXANE GPA 2261 0.0000 % mol
NITROGEN GPA 2261 0.2800 % mol
CARBON DIOXIDE GPA 2261 0.0000 % mol
OXYGEN GPA 2261 0.0000 % mol
MERCURY ng / Nm3 NOT TESTED
MERCAPTANS mg / Nm3 NOT TESTED
HYDROGEN SULFIDE mg / Nm3 NOT TESTED
CARBONYL SULFIDE mg / Nm3 NOT TESTED
TOTAL SULFUR mg / Nm3 NOT TESTED
HYDROCARBON DEWPOINT (MAX) °C NOT TESTED
3. QUALITY SPECIFICATIONS (SPA DEFINED)
TEST SPECIFICATION RESULT
NONE SPECIFIED N/A N/A
4. ADDITIONAL INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
LNG-LD-009H1 (07-AUG-09) - 14
THE TEST RESULTS IN THIS DOCUMENT HAVE BEEN PROVIDED TO INTERTEK CALEB BRETT BY THE TERMINAL AND ARE
PASSED ON FOR INFORMATIONAL PURPOSES ONLY. INTERTEK CALEB BRETT MAKES NO REPRESENTATION AS TO THE
QUALITY OF THE MATERIAL AND ASSUMES NO RESPONSIBILITY FOR THE ACCURACY OF THE TEST RESULTS, WHICH
REMAINS SOLELY WITH THE ABOVE MENTIONED PRODUCER OF THE RESULTS. THE ISSUING OF THIS REPORT DOES NOT
CONSTITUTE ANY REPRESENTATION OR WARRANTY CONCERNING THE INFORMATION CONTAINED HEREIN.
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F G A S - U P
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. METHOD OF GAS-UP CALCULATION
2. CALCULATION OF VAPOR VOLUME USED FOR GAS-UP
TANK NAME 1 2 3 4
TANK CAPACITY 37,326.000 37,336.000 37,352.000 37,345.000
FACTOR 1.800 1.800 1.800 1.800
VOLUME USED 67,186.800 67,204.800 67,233.600 67,221.000
3. CALCULATION VALUES FOR GAS-UP OPERATIONS
VAPOR VOLUME USED FOR GAS-UP = 268,846.200 CUBIC METERS
VAPOR TEMPERTURE AFTER GAS-UP = 24.0 °C
VAPOR PRESSURE AFTER GAS-UP = 1171 mbar
DENSITY OF VAPOR VOLUME FOR GAS-UP = 0.7634 kg / m3 at 60°F (Ideal Gas)
DENSITY OF LIQUID (AT LNG LOADING TEMPERATURE) = 459.080 kg / m3 at -160.2°C
HIGHER HEATING VALUE (MASS) = 54.436 MJ / kg at 15°C
HIGHER HEATING VALUE (VOLUME) = 1115 BTU / SCF at 60/60°F & 14.696 psi
4. VOLUME, MASS, & ENERGY USED FOR GAS-UP OPERATIONS
LNG EQUIVALENT USED FOR GAS-UP = 501.918 CUBIC METERS at -160.2°C
MASS REQUIRED FOR GAS-UP = 230.420 METRIC TONS
ENERGY REQUIRED FOR GAS-UP = 12,542,489 MJ at @ 60°F
ENERGY REQUIRED FOR GAS-UP = 11,888 MMBTU at @ 60°F
ENERGY REQUIRED FOR GAS-UP = 3,484,025 MMBTU at @ 60°F
5. ADDITION INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
ROGU 1 - Factor Calculation LNG-LD-009H1 (07-AUG-09) - 14
GAS-UP VALUES ARE CALCULATED BY MULTIPLYING TANK CAPACITY BY A CONSTANT VOLUME FACTOR SUBMITTED BY THE VESSEL. THE FACTOR IS DETERMINED BY THE DESIGN OF THE VESSEL TANKS.
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F G A S - U P
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. METHOD OF GAS-UP CALCULATION
2. SUBMITTED VOLUME USED FOR GAS-UP
SUBMITTED VOLUME USED FOR GAS-UP = 263,487.600 CUBIC METERS (VAPOR)
3. CALCULATION VALUES FOR GAS-UP OPERATIONS
VAPOR VOLUME USED FOR GAS-UP = 263,487.600 CUBIC METERS
VAPOR TEMPERTURE AFTER GAS-UP = 24.0 °C
VAPOR PRESSURE AFTER GAS-UP = 1171 mbar
DENSITY OF VAPOR VOLUME FOR GAS-UP = 0.7634 kg / m3 at 60°F (Ideal Gas)
DENSITY OF LIQUID (AT LNG LOADING TEMPERATURE) = 459.080 kg / m3 at -160.2°C
HIGHER HEATING VALUE (MASS) = 54.436 MJ / kg at 15°C
HIGHER HEATING VALUE (VOLUME) = 1115 BTU / SCF at 60/60°F & 14.696 psi
4. VOLUME, MASS, & ENERGY USED FOR GAS-UP OPERATIONS
LNG EQUIVALENT USED FOR GAS-UP = 491.914 CUBIC METERS at -160.2°C
MASS REQUIRED FOR GAS-UP = 225.828 METRIC TONS
ENERGY REQUIRED FOR GAS-UP = 12,289,447 MJ at @ 60°F
ENERGY REQUIRED FOR GAS-UP = 11,648 MMBTU at @ 60°F
ENERGY REQUIRED FOR GAS-UP = 3,413,735 MMBTU at @ 60°F
5. ADDITION INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
ROGU 1 - Factor Calculation LNG-LD-009H1 (07-AUG-09) - 14
GAS-UP VALUES ARE CALCULATED BY MUTIAL AGREEMENT BETWEEN ALL PARTIES. THE VOLUME AS CALCUALTED BY FLOW METER LOCATED ASHORE. THE VOLUME REPORTED WAS SUBMITTED BY THE TERMINAL.
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C O O L D O W N
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. METHOD OF COOL DOWN CALCULATION
COOL DOWN VALUES ARE CALCULATED BY THE LIQUID VOLUME PER VAPOR TEMPERATURE DIFFERENTIAL METHOD.
2. PROCEDURE FOR METHOD
THE DIFFERENCE OF THE VAPOR TEMPERATURES TAKEN DURING OPENING CUSTODY TRANSFER AND AFTER COOL DOWN
MEASUREMENT IS MULTIPLIED BY A LIQUID VOLUME PER 1°C. THIS LIQUID VOLUME IS DEFINED WITHIN THE VESSEL'S
CALIBRATION TABLES AND IS SUBMITTED BY THE CHIEF OFFICER.
THE TANK TEMPERATURE IS IDENTIFIED AS : THE AVERAGE OF ONLY THE BOTTOM 2 TEMPERATURE PROBES
LIQUID VOLUME REQUIRED TO LOWER THE VAPOR TEMPERATURE BY 1°C = 2.150 CUBIC METERS
CALCULATED DENSITY OF CARGO LOADED = 459.080 kg / m3 at -160.2 °C
HIGHER HEATING VALUE OF CARGO LOADED = 54.4361 MJ / kg at 15°C
3. TANK TEMPERATURE CALCULATIONS
TANK NAME 1 2 3 4
TEMP. PRIOR °C 28.00 28.00 27.00 27.00
TEMP. AFTER °C CASE #1 CASE #1 CASE #1 CASE #1
TEMP. DIFF °C #VALUE! #VALUE! #VALUE! #VALUE!
2.150 2.150 2.150 2.150
#VALUE! #VALUE! #VALUE! #VALUE!
4. REPORTING VALUES FOR COOL DOWN OPERATIONS
LIQUID VOLUME REQUIRED FOR COOL DOWN = #VALUE! CUBIC METERS at -160.2 °C
MASS REQUIRED FOR COOL DOWN = #VALUE! METRIC TONS
ENERGY REQUIRED FOR COOL DOWN = #VALUE! MJ at @ 60°F
ENERGY REQUIRED FOR COOL DOWN = #VALUE! MMBTU at @ 60°F
ENERGY REQUIRED FOR COOL DOWN = #VALUE! KWH at @ 60°F
5. ADDITION INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
ROCD 1 - Temperature Differential LNG-LD-009H1 (07-AUG-09) - 14
M3 PER 1°C
M3 PER TANK
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C O O L D O W N
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. METHOD OF COOL DOWN CALCULATION
COOL DOWN VALUES ARE CALCULATED BY THE COOL DOWN TABLES METHOD.
2. PROCEDURE FOR METHOD
THE ENERGY REQUIRED TO COOL DOWN THE VESSEL TANKS TO THE REQUIRED LOADING TEMPERATURE IS OBTAINED
FROM VESSEL'S CERTIFIED COOL DOWN TABLES SUBMITTED BY THE CHIEF OFFICIER. THE TABLES ARE DIVIDED INTO
TWO SECTIONS. CASE #1 IS FOR WARM CONDITIONS (AVERAGE TEMPERTAURE BEING HIGHER THAN -40°C). CASE #2
IS FOR COLD CONDITIONS (AVERAGE TEMPERATURE BEING LOWER THAN -40°C).
THE TANK TEMPERATURE IS IDENTIFIED AS : THE AVERAGE OF ONLY THE TOP & BOTTOM TEMPERATURE PROBES
COOL DOWN TABLES PRESENTED USING : MMBTUS
TEMPERATURES FOR CASE #1 TABLES ARE BETWEEN 40.0 °C AND -40.0 °C
TEMPERATURES FOR CASE #2 TABLES ARE BETWEEN -40.0 °C AND -130.0 °C
CALCULATED DENSITY OF CARGO LOADED = 459.080 kg / m3 at -160.2 °C
HIGHER HEATING VALUE OF CARGO LOADED = 54.4361 MJ / kg at 15°C
3. TANK TEMPERATURE CALCULATIONS
TANK NAME 1 2 3 4
TEMPERATURE °C 28.00 28.00 27.00 27.00
TABLE USED CASE #2 CASE #2 CASE #2 CASE #2
MMBTUS 1625 2988 2988 2794
4. REPORTING VALUES FOR COOL DOWN OPERATIONS
LIQUID VOLUME REQUIRED FOR COOL DOWN = 438.860 CUBIC METERS at -160.2 °C
MASS REQUIRED FOR COOL DOWN = 201.472 METRIC TONS
ENERGY REQUIRED FOR COOL DOWN = 10,967,349 MJ at @ 60°F
ENERGY REQUIRED FOR COOL DOWN = 10,395 MMBTU at @ 60°F
ENERGY REQUIRED FOR COOL DOWN = 3,046,486 KWH at @ 60°F
5. ADDITION INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
ROCD 2 - Vessel Tables LNG-LD-009H1 (07-AUG-09) - 14
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C O O L D O W N
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. METHOD OF COOL DOWN CALCULATION
COOL DOWN VALUES ARE CALCULATED BY THE SPRAY NOZZLE FLOW & PRESSURE METHOD.
2. PROCEDURE FOR METHOD
THE VOLUME REQUIRED TO COOL DOWN THE VESSEL TANKS TO THE REQUIRED LOADING TEMPERATURE IS OBTAINED
BY CALCULATING THE VOLUME BASED ON THE NUMBER OF SPRAY NOZZLES PER TANK, FLOW CAPACITY PER NOZZLE,
DURATION OF COOL DOWN, AND THE DENSITY OF THE LNG.
CALCULATED DENSITY OF CARGO LOADED = 459.080 kg / m3 at -160.2 °C
HIGHER HEATING VALUE OF CARGO LOADED = 54.4361 MJ / kg at 15°C
3. TANK PROFILE
TANK NAME 1 2 3 4
# OF NOZZLES 22 34 34 32
FLOW RATE (L/MIN) 1.80 1.80 1.80 1.80
DURATION (HOURS) 9.80 9.80 9.80 9.80
DENSITY FACTOR 1.4759 1.4759 1.4759 1.4759
CUBIC METERS 34.366 53.111 53.111 49.987
4. REPORTING VALUES FOR COOL DOWN OPERATIONS
LIQUID VOLUME REQUIRED FOR COOL DOWN = 190.575 CUBIC METERS at -160.2 °C
MASS REQUIRED FOR COOL DOWN = 87.489 METRIC TONS
ENERGY REQUIRED FOR COOL DOWN = 4,762,303 MJ at @ 60°F
ENERGY REQUIRED FOR COOL DOWN = 4,514 MMBTU at @ 60°F
ENERGY REQUIRED FOR COOL DOWN = 1,322,862 KWH at @ 60°F
5. ADDITION INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
ROCD 3 - Nozzle Flow LNG-LD-009H1 (07-AUG-09) - 14
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C O O L D O W N
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. METHOD OF COOL DOWN CALCULATION
COOL DOWN VALUES ARE CALCULATED BY USING THE NIGERIA LNG TERMINAL SUBMITTED PROCEDURE.
2. PROCEDURE FOR METHOD
3. REPORTING VALUES FOR COOL DOWN OPERATIONS
LIQUID VOLUME REPORTED FOR COOL DOWN = 640.830 CUBIC METERS at -160.2 °C
DENSITY OF LNG = 459.080 kg / m3 at -160.2 °C
HIGHER HEATING VALUE (MASS) = 54.4361 MJ / kg at 15°C
MASS REQUIRED FOR COOL DOWN = 294.192 METRIC TONS
ENERGY REQUIRED FOR COOL DOWN = 16,013,781 MJ at @ 60°F
ENERGY REQUIRED FOR COOL DOWN = 15,178 MMBTU at @ 60°F
ENERGY REQUIRED FOR COOL DOWN = 4,448,273 KWH at @ 60°F
4. ADDITION INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
ROCD 4 - Submitted Shore LNG-LD-009H1 (07-AUG-09) - 14
THE ENERGEY REQUIRED TO COOL DOWN THE VESSEL TANKS TO THE REQUIRED LOADING TEMPERATURE IS OBTAINED BY THE COMMON INDUSTRY FORMULA OF "ENERGY = VOLUME * DENSITY * HIGHER HEATING VALUE (MASS BASED)". THE VOLUME OF LNG (IN CUBIC METERS) WAS SUBMITTED BY THE TERMINAL. THE DENSITY OF THE LNG WAS CALCULATED BY USING NBS TECHNICAL NOTE 1030 (1980). THE HIGHER HEATING VALUE (MASS BASED) WAS CALCULATED BY USING THE STANDARD ISO 6976.
PLEASE NOTE THAT WITH RESPECT TO THE CALCULATION OF COOL DOWN QUANTITY THE TERMINAL PROCEDURE DIFFERS FROM NORMAL ACCEPTED INDUSTRY PRACTISE, WE ARE HOWEVER REQUIRED TO REPORT THE QUANTITY IN ACCORDANCE WITH TERMINAL PROCEDURES.
14
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C O O L D O W N
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. METHOD OF COOL DOWN CALCULATION
COOL DOWN VALUES ARE CALCULATED BY THE COOL DOWN TABLES PLUS LIQUID FALL OUT METHOD.
2. PROCEDURE FOR METHOD
THE ENERGY REQUIRED TO COOL DOWN THE VESSEL TANKS TO THE REQUIRED LOADING TEMPERATURE IS OBTAINED
FROM VESSEL'S CERTIFIED COOL DOWN TABLES SUBMITTED BY THE CHIEF OFFICIER. THE TABLES ARE DIVIDED INTO
TWO SECTIONS. CASE #1 IS FOR WARM CONDITIONS (AVERAGE TEMPERTAURE BEING HIGHER THAN °C). CASE #2
IS FOR COLD CONDITIONS (AVERAGE TEMPERATURE BEING LOWER THAN °C).
THE TANK TEMPERATURE IS IDENTIFIED AS : THE AVERAGE OF TANK TEMPERATURES
COOL DOWN TABLES PRESENTED USING : MMBTUS
CALCULATED DENSITY OF CARGO LOADED = 459.080 kg / m3 at -160.2 °C
HIGHER HEATING VALUE OF CARGO LOADED = 54.4361 MJ / kg at 15°C
3. CALCULATIONS OF CONSUMED VALUES FOR COOL DOWN
TANK NAME 1 2 3 4
TEMP BEFORE °C 29.10 29.40 28.80 29.50
TEMP AFTER °C 30.10 29.40 28.80 29.50
MMBTUS 2473 3638 3626 3358
VOLUME OF LIQUID CONSUMED FOR COOL DOWN = 552.849 CUBIC METERS
MASS CONSUMED FOR COOL DOWN = 253.802 METRIC TONS
ENERGY CONSUMED FOR COOL DOWN = 13,815,237 MJ at 60°F
ENERGY CONSUMED FOR COOL DOWN = 13,090 MMBTU at 60°F
ENERGY CONSUMED FOR COOL DOWN = 3,837,566 KWH at 60°F
4. CALCULATIONS OF FALLOUT VALUES AFTER COOL DOWN
TANK NAME 1 2 3 4
VOLUME BEFORE m3 21.371 37.771 38.761 307.075
VOLUME AFTER m3 47.856 44.726 60.576 59.168
VOLUME LOADED m3 26.485 6.955 21.815 -247.907
VOLUME OF LIQUID FALLOUT AFTER COOL DOWN = 192.652 CUBIC METERS
MASS OF FALLOUT AFTER COOL DOWN = 88.443 METRIC TONS
ENERGY OF FALLOUT AFTER COOL DOWN = 4,814,205 MJ at 60°F
ENERGY OF FALLOUT AFTER COOL DOWN = 4,560 MMBTU at 60°F
ENERGY OF FALLOUT AFTER COOL DOWN = 1,337,279 KWH at 60°F
5. TOTAL VALUES FOR COOL DOWN OPERATIONS
TOTAL VOLUME OF LIQUID REQUIRED FOR COOL DOWN = 745.501 CUBIC METERS
TOTAL MASS REQUIRED FOR COOL DOWN = 342.245 METRIC TONS
TOTAL ENERGY REQUIRED FOR COOL DOWN = 18,629,442 MJ at 60°F
TOTAL ENERGY REQUIRED FOR COOL DOWN = 17,650 MMBTU at 60°F
TOTAL ENERGY REQUIRED FOR COOL DOWN = 5,174,845 KWH at 60°F
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
ROCD 5 - Vessel Tables + Fall Out LNG-LD-009H1 (07-AUG-09) - 14
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C A L C U L A T I O N S
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. COMPOSITION FACTORS
MOLAR MOLAR WT. MOLAR VOL. MOLAR HHV
COMPONENTS FRACTION kg / kmole MJ / kg
(Xi) (Mi) (Vi) (Hi)
METHANE 0.902400 16.043 0.038122 55.574
ETHANE 0.059500 30.070 0.047925 51.95
PROPANE 0.022400 44.097 0.062478 50.37
ISO BUTANE 0.006900 58.123 0.078332 49.39
N-BUTANE 0.005800 58.123 0.076856 49.55
ISO PENTANE 0.000200 72.150 0.091700 48.95
N-PENTANE + HEAVIER 0.000000 72.150 0.091562 49.04
NITROGEN 0.002800 28.0135 0.046882 0
2. DENSITY CALCULATIONS
DENSITY = WITH C = K1 + ( K2 - K1 ) * Xn
0.0425
DENSITY = 459.166 kg/m3 at -160.2 °C K1 = 0.000427 K2 = 0.000685
3. HIGHER HEATING VALUES
= = 54.4355 MJ / kg
= = 41.63578.31451 * 288.15
= = 52.689528.9626
4. QUANTITIES DELIVERED
LIQUID TEMPERATURE AFTER LOADING = -160.2 °C VESSEL O.C.T. VOLUME = 404.978
VAPOR TEMPERATURE BEFORE LOADING = -128.5 °C VESSEL C.C.T. VOLUME = 136,292.944
ABSOLUTE PRESSURE BEFORE LOADING = 1166.000 mbar LOADED VOLUME = 135,887.966
5. ENERGY DELIVERED
GROSS QUANTITY DELIVERED = VOLUME * DENSITY * HIGHER HEATING VALUE (MASS BASED)
GROSS DELIVERED QUANTITY = 3,396,507,919 MJ
GROSS DELIVERED QUANTITY = 3,219,267.90 MMBTU
GROSS DELIVERED QUANTITY = 943,474,422 KWH
6. ADDITIONAL INFORMATION AND COMMENTS
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 15°C.
THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON N.B.S. TECHNICAL NOTE 1030 (1980).
THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO I.S.O. 6976 (1995).
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
SPA Contract # 1 LNG-LD-009H1 (07-AUG-09) - 14
m3 / kmole
S ( Xi * Mi )
S ( Xi * Vi ) - Xm * C
Hm (MASS) 15°C
S ( Xi * Mi * Hi ) Hm (MASS) 15°CS ( Xi * Mi )
Hv (VOLUME) 15/15°C at 101.325 kPa
S ( Xi * Mi * Hi) * 101.325 Hv (VOLUME) 15/15°C at 101.325 kPa
MJ / m3
WOBBE INDEX 15/15°C at 101.325 kPa
Hv / ÖS ( Xi * Mi ) WOBBE INDEX
15/15°C at 101.325 kPa
MJ / m3
m3
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C A L C U L A T I O N S
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. COMPOSITION FACTORS
MOLAR MOLAR WT. MOLAR VOL. MOLAR HHV MOLAR HHV SUMMATION
COMPONENTS FRACTION kg / kmole MJ / kg FACTOR
(Xi) (Mi) (Vi) (Hmi) (Hvi)
METHANE 0.902400 16.043 0.038118 55.574 37.706 0.0447
ETHANE 0.059500 30.070 0.047922 51.95 66.07 0.0922
PROPANE 0.022400 44.097 0.062475 50.37 93.94 0.1338
ISO BUTANE 0.006900 58.123 0.078328 49.39 121.40 0.1789
N-BUTANE 0.005800 58.123 0.076852 49.55 121.79 0.1871
ISO PENTANE 0.000200 72.150 0.091695 48.95 149.36 0.2280
N-PENTANE 0.000000 72.150 0.091558 49.04 149.66 0.2510
N-HEXANE 0.000000 86.177 0.104864 48.72 177.55 0.2950
NITROGEN 0.002800 28.0135 0.046876 0 0 0.0173
OXYGEN 0.000000 31.9988 0.031467 0 0 0.0283
2. DENSITY CALCULATIONS
DENSITY = WITH C = K1 + ( K2 - K1 ) * Xn
0.0425
DENSITY = 459.159 kg/m3 at -160.24 °C K1 = 0.000422 K2 = 0.000681
3. HIGHER HEATING VALUES
= = 54.4355 MJ / kg
= = 41.7448
= *0.99958
= 52.769228.9626 Z
4. QUANTITIES DELIVERED
LIQUID TEMPERATURE AFTER LOADING = -160.24 °C VESSEL O.C.T. VOLUME = 404.978
VAPOR TEMPERATURE BEFORE LOADING = -128.49 °C VESSEL C.C.T. VOLUME = 136,292.944
ABSOLUTE PRESSURE BEFORE LOADING = 1166.000 mbar LOADED VOLUME = 135,887.966
5. ENERGY DELIVERED
QUANTITY = V * D * Hm - Qr WITH Qr = V * 288.15
*Pa
* 37.782 (Real Gas)( 273.15 + Tv ) 1013.25
GROSS QUANTITY = 3,396,458,942 MJ or 3,219,221.48 MMBTU or 943,460,817 KWH
ENERGY DISPLACED = 11,768,417 MJ or 11,154.31 MMBTU or 3,269,005 KWH
NET QUANTITY = 3,384,690,525 MJ or 3,208,067.18 MMBTU or 940,191,812 KWH
6. ADDITIONAL INFORMATION AND COMMENTS
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 15°C.
THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON I.S.O. 6578 (1991).
THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO I.S.O. 6976 (1995).
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
SPA Contract # 2 LNG-LD-009H1 (07-AUG-09) - 14
m3 / kmole MJ / m3
(ÖBi)
S ( Xi * Mi )
S ( Xi * Vi ) - Xm * C
Hm (MASS) 15°C
S ( Xi * Mi * Hmi ) Hm (MASS) 15°CS ( Xi * Mi )
Hv (VOLUME) 15/15°C at 101.325 kPa
S ( Xi * Hvi ) / ZHv (VOLUME) 15/15°C at 101.325 kPa
MJ / m3
WOBBE INDEX 15/15°C at 101.325 kPa
Hv / ÖS ( Xi * Mi ) WOBBE INDEX
15/15°C at 101.325 kPa
MJ / m3
m3
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C A L C U L A T I O N S
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. COMPOSITION FACTORS
MOLAR MOLAR WT. MOLAR VOL. MOLAR HHV
COMPONENTS FRACTION kg / kmole MJ / kg
(Xi) (Mi) (Vi) (Hi)
METHANE 0.9024 16.043 0.038122 55.574
ETHANE 0.0595 30.070 0.047925 51.95
PROPANE 0.0224 44.097 0.062478 50.37
ISO BUTANE 0.0069 58.123 0.078332 49.39
N-BUTANE 0.0058 58.123 0.076856 49.55
ISO PENTANE 0.0002 72.150 0.091700 48.95
N-PENTANE + HEAVIER 0.0000 72.150 0.091562 49.04
NITROGEN 0.0028 28.0135 0.046882 0
2. DENSITY CALCULATIONS
DENSITY = WITH C = K1 + ( K2 - K1 ) * Xn
0.0425
DENSITY = 459.16 kg/m3 at -160.2 °C K1 = 0.000427 K2 = 0.000685
3. HIGHER HEATING VALUES
= = 54.4 MJ / kg
= * 26.8392 = 1117.5 BTU / SCF23.6449
= = 1414.2 BTU / SCF28.9626
4. QUANTITIES DELIVERED
LIQUID TEMPERATURE AFTER LOADING = -160.2 °C VESSEL O.C.T. VOLUME = 404.978
VAPOR TEMPERATURE BEFORE LOADING = -128.5 °C VESSEL C.C.T. VOLUME = 136,292.944
ABSOLUTE PRESSURE BEFORE LOADING = 1166 mbar LOADED VOLUME = 135,887.000
5. ENERGY DELIVERED
Q = ( V * D * Hm - Qr ) / 1055.12 With Qr = V * 288.15
*Pa
* 37.7 (Ideal Gas)( 273.15 + Tv ) 1013.25
GROSS QUANTITY = 3,394,020,913 MJ or 3,216,911 MMBTU or 942,783,587 KWH
ENERGY DISPLACED = 11,742,891 MJ or 11,130 MMBTU or 3,261,914 KWH
NET QUANTITY = 3,382,277,424 MJ or 3,205,780 MMBTU or 939,521,673 KWH
6. ADDITIONAL INFORMATION AND COMMENTS
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F.
THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON N.B.S. TECHNICAL NOTE 1030 (1980).
THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO I.S.O. 6976 (1995).
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
SPA Contract # 3 LNG-LD-009H1 (07-AUG-09) - 14
m3 / kmole
S ( Xi * Mi )
S ( Xi * Vi ) - Xm * C
Hm (MASS) 15°C
S ( Xi * Mi * Hi ) Hm (MASS) 15°CS ( Xi * Mi )
Hv (VOLUME) 60/60°F at 14.696 PSI
S ( Xi * Mi * Hi) Hv (VOLUME) 60/60°F at 14.696 PSI
WOBBE INDEX 60/60°F at 14.696 PSI
Hv / ÖS ( Xi * Mi ) WOBBE INDEX
60/60°F at 14.696 PSI
m3
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C A L C U L A T I O N S
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. COMPOSITION FACTORS
MOLAR MOLAR WT. MOLAR VOL. MOLAR HHV
COMPONENTS FRACTION kg / kmole MJ / kg
(Xi) (Mi) (Vi) (Hi)
METHANE 0.902400 16.043 0.038116 55.574
ETHANE 0.059500 30.070 0.047922 51.95
PROPANE 0.022400 44.097 0.062475 50.37
ISO BUTANE 0.006900 58.123 0.078328 49.39
N-BUTANE 0.005800 58.123 0.076852 49.55
ISO PENTANE 0.000200 72.150 0.091695 48.95
N-PENTANE + HEAVIER 0.000000 72.150 0.091558 49.04
NITROGEN 0.002800 28.0135 0.046855 0
2. DENSITY CALCULATIONS
DENSITY = WITH C = K1 + ( K2 - K1 ) * Xn
0.0425
DENSITY = 459.226 kg/m3 at -160.24 °C K1 = 0.000427 K2 = 0.000683
3. HIGHER HEATING VALUES
= = 54.436 MJ / kg
= = 41.63623.6449
= = 52.69028.9626
4. QUANTITIES DELIVERED
LIQUID TEMPERATURE AFTER LOADING = -160.24 °C VESSEL O.C.T. VOLUME = 404.978
VAPOR TEMPERATURE BEFORE LOADING = -128.49 °C VESSEL C.C.T. VOLUME = 136,292.944
ABSOLUTE PRESSURE BEFORE LOADING = 1166 mbar LOADED VOLUME = 135,887.966
5. ENERGY DELIVERED
GROSS QUANTITY DELIVERED = VOLUME * DENSITY * HIGHER HEATING VALUE (MASS BASED)
GROSS DELIVERED QUANTITY = 3,396,985,335 MJ
GROSS DELIVERED QUANTITY = 3,219,720 MMBTU
GROSS DELIVERED QUANTITY = 943,607,038 KWH
6. ADDITIONAL INFORMATION AND COMMENTS
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 15°C.
THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON N.B.S. TECHNICAL NOTE 1030 (1980).
THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO I.S.O. 6976 (1995).
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
m3 / kmole
S ( Xi * Mi )
S ( Xi * Vi ) - Xm * C
Hm (MASS) 15°C
S ( Xi * Mi * Hi ) Hm (MASS) 15°CS ( Xi * Mi )
Hv (VOLUME) 15/15°C at 101.325 kPa
S ( Xi * Mi * Hi) Hv (VOLUME) 15/15°C at 101.325 kPa
MJ / m3
WOBBE INDEX 15/15°C at 101.325 kPa
Hv / ÖS ( Xi * Mi ) WOBBE INDEX
15/15°C at 101.325 kPa
MJ / m3
m3
m3
m3
SPA Contract # 4 LNG-LD-009H1 (07-AUG-09) - 14
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C A L C U L A T I O N S
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. COMPOSITION FACTORS
MOLAR MOLAR WT. MOLAR VOL. MOLAR HHV
COMPONENTS FRACTION kg / kmole MJ / kg
(Xi) (Mi) (Vi) (Hi)
METHANE 0.902400 16.043 0.038122 55.516
ETHANE 0.059500 30.070 0.047925 51.9
PROPANE 0.022400 44.097 0.062478 50.33
ISO BUTANE 0.006900 58.123 0.078332 49.35
N-BUTANE 0.005800 58.123 0.076856 49.51
ISO PENTANE 0.000200 72.150 0.091700 48.91
N-PENTANE + HEAVIER 0.000000 72.150 0.091562 49.01
NITROGEN 0.002800 28.0135 0.046882 0
2. DENSITY CALCULATIONS
DENSITY = WITH C = K1 + ( K2 - K1 ) * Xn
0.0425
DENSITY = 459.166 kg/m3 at -160.2 °C K1 = 0.000427 K2 = 0.000685
3. HIGHER HEATING VALUES
= = 54.3803 MJ / kg
= = 41.70308.31451 * 288.15 * Z
= *0.99958
= 52.716328.9626 Z
4. QUANTITIES DELIVERED
LIQUID TEMPERATURE AFTER LOADING = -160.2 °C VESSEL O.C.T. VOLUME = 404.978
VAPOR TEMPERATURE BEFORE LOADING = -128.5 °C VESSEL C.C.T. VOLUME = 136,292.944
ABSOLUTE PRESSURE BEFORE LOADING = 1166 mbar LOADED VOLUME = 135,888.000
5. ENERGY DELIVERED
QUANTITY = V * D * Hm - Qr WITH Qr = V * 288.15
*Pa
* 38.8 (Real Gas)( 273.15 + Tv ) 1013.25
GROSS QUANTITY = 3,393,063,009 MJ or 3,216,002.76 MMBTU or 942,517,503 KWH
ENERGY DISPLACED = 12,086,344 MJ or 11,455.64 MMBTU or 3,357,318 KWH
NET QUANTITY = 3,380,976,665 MJ or 3,204,547.12 MMBTU or 939,160,185 KWH
6. ADDITIONAL INFORMATION AND COMMENTS
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 25°C.
THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON N.B.S. TECHNICAL NOTE 1030 (1980).
THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO I.S.O. 6976 (1995).
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
SPA Contract # 5 LNG-LD-009H1 (07-AUG-09) - 14
m3 / kmole
S ( Xi * Mi )
S ( Xi * Vi ) - Xm * C
Hm (MASS) 25°C
S ( Xi * Mi * Hi ) Hm (MASS) 25°CS ( Xi * Mi )
Hv (VOLUME) 25/15°C at 101.325 kPa
S ( Xi * Mi * Hi) * 101.325 Hv (VOLUME) 25/15°C at 101.325 kPa
MJ / m3
WOBBE INDEX 25/15°C at 101.325 kPa
Hv / ÖS ( Xi * Mi ) WOBBE INDEX
25/15°C at 101.325 kPa
MJ / m3
m3
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C A L C U L A T I O N S
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. COMPOSITION FACTORS
MOLAR MOLAR WT. MOLAR VOL. MOLAR HHV
COMPONENTS FRACTION kg / kmole MJ / kg
(Xi) (Mi) (Vi) (Hi)
METHANE 0.9024 16.043 0.038122 55.560
ETHANE 0.0595 30.070 0.047925 51.926
PROPANE 0.0224 44.097 0.062479 50.393
ISO BUTANE 0.0069 58.124 0.078332 49.402
N-BUTANE 0.0058 58.124 0.076857 49.544
ISO PENTANE 0.0002 72.151 0.091699 48.944
N-PENTANE 0.0000 72.151 0.091562 49.053
N-HEXANE 0.0000 86.178 0.104877 48.719
NITROGEN 0.0028 28.013 0.046866 0
CARBON DIOXIDE 0.0000 44.010 0.027180 0
OXYGEN 0.0000 31.999 0.031474 0
2. DENSITY CALCULATIONS
DENSITY = WITH C = K1 + ( K2 - K1 ) * Xn
0.0425
DENSITY = 459.082 kg/m3 at -160.2 °C K1 = 0.000419 K2 = 0.000685
3. HIGHER HEATING VALUES
= = 54.4233 MJ / kg
= = 1115.0 BTU / SCF
= = 1411.0 BTU / SCF28.9626
4. QUANTITIES DELIVERED
LIQUID TEMPERATURE AFTER LOADING = -160.2 °C VESSEL O.C.T. VOLUME = 404.978
VAPOR TEMPERATURE BEFORE LOADING = -128.5 °C VESSEL C.C.T. VOLUME = 136,292.944
ABSOLUTE PRESSURE BEFORE LOADING = 1166 mbar LOADED VOLUME = 135,888.000
5. ENERGY DELIVERED
Q = ( V * D * Hm - Qr ) / 1055.12 With Qr = V * 288.15
*Pa
* 37.7 (Ideal Gas)( 273.15 + Tv ) 1013.25
GROSS QUANTITY = 3,394,935,649 MJ or 3,217,765 MMBTU or 943,037,680 KWH
ENERGY DISPLACED = 11,743,022 MJ or 11,130 MMBTU or 3,261,951 KWH
NET QUANTITY = 3,383,192,627 MJ or 3,206,640 MMBTU or 939,775,730 KWH
6. ADDITIONAL INFORMATION AND COMMENTS
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F.
THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON N.B.S. INTERAGENCY REPORT 77-867.
THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO I.P. 251/76.
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
SPA Contract # 6 LNG-LD-009H1 (07-AUG-09) - 14
m3 / kmole
S ( Xi * Mi )
S ( Xi * Vi ) - Xm * C
Hm (MASS) 15°C
S ( Xi * Mi * Hi ) Hm (MASS) 15°CS ( Xi * Mi )
Hv (VOLUME) 60/60°F at 14.696 PSIA
1.13285 * S ( Xi * Mi * Hi )Hv (VOLUME) 60/60°F at 14.696 PSIA
WOBBE INDEX 60/60°F at 14.696 PSIA
Hv / ÖS ( Xi * Mi ) WOBBE INDEX
60/60°F at 14.696 PSIA
m3
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C A L C U L A T I O N S
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. COMPOSITION FACTORS
MOLAR MOLAR WT. MOLAR VOL. MOLAR HHV MOLAR HHV SUMMATION
COMPONENTS FRACTION kg / kmole MJ / kg FACTOR
(Xi) (Mi) (Vi) (Hmi) (Hvi)
METHANE 0.9024 16.0426 0.038123 55.574 39.777 0.0490
ETHANE 0.0595 30.0694 0.047925 51.95 69.69 0.1000
PROPANE 0.0224 44.0962 0.062479 50.37 99.09 0.1453
ISO BUTANE 0.0069 58.1230 0.078332 49.39 128.07 0.2049
N-BUTANE 0.0058 58.1230 0.076856 49.55 128.48 0.2069
ISO PENTANE 0.0002 72.1498 0.091699 48.95 157.57 0.2510
N-PENTANE 0.0000 72.1498 0.091562 49.04 157.87 0.2864
N-HEXANE 0.0000 86.1760 0.104868 48.72 187.30 0.3286
NITROGEN 0.0028 28.0134 0.046900 0 0 0.0224
OXYGEN 0.0000 31.9988 0.031474 0 0 0.0316
2. DENSITY CALCULATIONS
DENSITY = WITH C = K1 + ( K2 - K1 ) * Xn
0.0425
DENSITY = 459.093 kg/m3 at -160.2 °C K1 = 0.000423 K2 = 0.000682
3. HIGHER HEATING VALUES
= = 54.44 MJ / kg
= = 44.06
= *0.99941
= 55.6928.9626 Z
4. QUANTITIES DELIVERED
LIQUID TEMPERATURE AFTER LOADING = -160.2 °C VESSEL O.C.T. VOLUME = 404.978
VAPOR TEMPERATURE BEFORE LOADING = -128.5 °C VESSEL C.C.T. VOLUME = 136,292.944
ABSOLUTE PRESSURE BEFORE LOADING = 1166 mbar LOADED VOLUME = 135,887.966
5. ENERGY DELIVERED
GROSS QUANTITY DELIVERED = VOLUME * DENSITY * HIGHER HEATING VALUE (MASS BASED)
GROSS DELIVERED QUANTITY = 3,396,251,049 MJ
GROSS DELIVERED QUANTITY = 3,219,024 MMBTU
GROSS DELIVERED QUANTITY = 943,403,069 KWH
6. ADDITIONAL INFORMATION AND COMMENTS
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 15°C.
THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON I.S.O. 6578 (1991).
THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO I.S.O. 6976 (1995).
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
SPA Contract # 7 LNG-LD-009H1 (07-AUG-09) - 14
m3 / kmole MJ / m3
(ÖBi)
S ( Xi * Mi )
S ( Xi * Vi ) - Xm * C
Hm (MASS) 15°C
S ( Xi * Mi * Hmi ) Hm (MASS) 15°CS ( Xi * Mi )
Hv (VOLUME) 15/0°C at 101.325 kPa
S ( Xi * Hvi ) / ZHv (VOLUME) 15/0°C at 101.325 kPa
MJ / m3
WOBBE INDEX 15/0°C at 101.325 kPa
Hv / ÖS ( Xi * Mi ) WOBBE INDEX
15/0°C at 101.325 kPa
MJ / m3
m3
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C A L C U L A T I O N S
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. COMPOSITION FACTORS
MOLAR MOLAR WT. MOLAR VOL. MOLAR HHV
COMPONENTS FRACTION kg / kmole MJ / kg
(Xi) (Mi) (Vi) (Hi)
METHANE 0.9024 16.043 0.038123 55.575
ETHANE 0.0595 30.070 0.047925 51.950
PROPANE 0.0224 44.097 0.062479 50.368
ISO BUTANE 0.0069 58.123 0.078332 49.388
N-BUTANE 0.0058 58.123 0.076856 49.546
ISO PENTANE 0.0002 72.150 0.091699 48.949
N-PENTANE 0.0000 72.150 0.091562 49.045
N-HEXANE 0.0000 86.177 0.104868 48.716
NITROGEN 0.0028 28.013 0.046900 0
CARBON DIOXIDE 0.0000 44.010 ----- 0
OXYGEN 0.0000 31.9988 0.031474 0
2. DENSITY CALCULATIONS
DENSITY = WITH C = K1 + ( K2 - K1 ) * Xn
0.0425
DENSITY = 459.08 kg/m3 at -160.2 °C K1 = 0.00042 K2 = 0.00068
3. HIGHER HEATING VALUES
= = 54.4361 MJ / kg
= = 1115.3 BTU / SCF
= = 1411.4 BTU / SCF28.9626
4. QUANTITIES DELIVERED
LIQUID TEMPERATURE AFTER LOADING = -160.2 °C VESSEL O.C.T. VOLUME = 405
VAPOR TEMPERATURE BEFORE LOADING = -128.5 °C VESSEL C.C.T. VOLUME = 136,293
ABSOLUTE PRESSURE BEFORE LOADING = 116.6 kPa LOADED VOLUME = 135,888
5. ENERGY DELIVERED
GROSS QUANTITY DELIVERED = VOLUME * DENSITY * HIGHER HEATING VALUE (MASS BASED)
GROSS DELIVERED QUANTITY = 3,395,912,432 MJ
GROSS DELIVERED QUANTITY = 3,218,703 MMBTU
GROSS DELIVERED QUANTITY = 943,309,009 KWH
6. ADDITIONAL INFORMATION AND COMMENTS
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 15°C.
THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON I.P. PART XII (1998).
THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO GPA 2145 SI (2000).
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
SPA Contract # 8 LNG-LD-009H1 (07-AUG-09) - 14
m3 / kmole
S ( Xi * Mi )
S ( Xi * Vi ) - Xm * C
Hm (MASS) 15°C
S ( Xi * Mi * Hi ) Hm (MASS) 15°CS ( Xi * Mi )
Hv (VOLUME) 60/60°F at 14.696 PSIA
1.13285 * S ( Xi * Mi * Hi )Hv (VOLUME) 60/60°F at 14.696 PSIA
WOBBE INDEX 60/60°F at 14.696 PSIA
Hv / ÖS ( Xi * Mi ) WOBBE INDEX
60/60°F at 14.696 PSIA
m3
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C A L C U L A T I O N S
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. COMPOSITION FACTORS
MOLAR MOLAR WT. MOLAR VOL. MOLAR HHV
COMPONENTS FRACTION kg / kmole MJ / kg
(Xi) (Mi) (Vi) (Hi)
METHANE 0.9024 16.043 0.038122 55.575
ETHANE 0.0595 30.070 0.047925 51.950
PROPANE 0.0224 44.097 0.062479 50.368
ISO BUTANE 0.0069 58.123 0.078332 49.388
N-BUTANE 0.0058 58.123 0.076857 49.546
ISO PENTANE 0.0002 72.150 0.091699 48.949
N-PENTANE 0.0000 72.150 0.091562 49.045
N-HEXANE 0.0000 86.177 0.104877 48.716
NITROGEN 0.0028 28.013 0.046866 0
CARBON DIOXIDE 0.0000 44.010 0.027180 0
2. DENSITY CALCULATIONS
DENSITY = WITH C = K1 + ( K2 - K1 ) * Xn
0.0425
DENSITY = 459.08 kg/m3 at -160.2 °C K1 = 0.000419 K2 = 0.000685
3. HIGHER HEATING VALUES
= = 54.4361 MJ / kg
= = 1115.3 BTU / SCF
= = 1411.4 BTU / SCF28.9626
4. QUANTITIES DELIVERED
LIQUID TEMPERATURE AFTER LOADING = -160.2 °C VESSEL O.C.T. VOLUME = 404.978
VAPOR TEMPERATURE BEFORE LOADING = -128 °C VESSEL C.C.T. VOLUME = 136,292.944
ABSOLUTE PRESSURE BEFORE LOADING = 1166 mbar LOADED VOLUME = 135,887.000
5. ENERGY DELIVERED
Q = ( V * D * Hm - DV ) / 1055.12 With DV = V * 288.15
*Pa
* 37.7 * C C = ( 0.5 )( 273.15 + Tv ) 1013.25
GROSS QUANTITY = 3,395,694,333 MJ or 3,218,485 MMBTU or 943,248,426 KWH
ENERGY DISPLACED = 5,851,242 MJ or 5,546 MMBTU or 1,625,345 KWH
NET QUANTITY = 3,389,843,091 MJ or 3,212,940 MMBTU or 941,623,081 KWH
6. ADDITIONAL INFORMATION AND COMMENTS
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F.
THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON N.B.S. INTERAGENCY REPORT 77-867.
THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO GPA 2145 SI (1992).
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
SPA Contract # 9 LNG-LD-009H1 (07-AUG-09) - 14
m3 / kmole
S ( Xi * Mi )
S ( Xi * Vi ) - Xm * C
Hm (MASS) 15°C
S ( Xi * Mi * Hi ) Hm (MASS) 15°CS ( Xi * Mi )
Hv (VOLUME) 60/60°F at 14.696 PSIA
1.13285 * S ( Xi * Mi * Hi )Hv (VOLUME) 60/60°F at 14.696 PSIA
WOBBE INDEX 60/60°F at 14.696 PSIA
Hv / ÖS ( Xi * Mi ) WOBBE INDEX
60/60°F at 14.696 PSIA
m3
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C A L C U L A T I O N S
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. COMPOSITION FACTORS
MOLAR MOLAR WT. MOLAR VOL. MOLAR HHV
COMPONENTS FRACTION kg / kmole MJ / kg
(Xi) (Mi) (Vi) (Hi)
METHANE 0.9024 16.043 0.038123 55.575
ETHANE 0.0595 30.070 0.047925 51.950
PROPANE 0.0224 44.097 0.062479 50.368
ISO BUTANE 0.0069 58.123 0.078332 49.388
N-BUTANE 0.0058 58.123 0.076856 49.546
ISO PENTANE 0.0002 72.150 0.091699 48.949
N-PENTANE 0.0000 72.150 0.091562 49.045
N-HEXANE 0.0000 86.177 0.104868 48.716
NITROGEN 0.0028 28.013 0.046900 0
CARBON DIOXIDE 0.0000 44.010 0.027183 0
OXYGEN 0.0000 31.9988 0.031474 0
2. DENSITY CALCULATIONS
DENSITY = WITH C = K1 + ( K2 - K1 ) * Xn
0.0425
DENSITY = 459.11 kg/m3 at -160.2 °C K1 = 0.000423 K2 = 0.000682
3. HIGHER HEATING VALUES
= = 54.4361 MJ / kg
= = 1115.3 BTU / SCF
= = 1411.4 BTU / SCF28.9626
4. QUANTITIES DELIVERED
LIQUID TEMPERATURE AFTER LOADING = -160.2 °C VESSEL O.C.T. VOLUME = 404.978
VAPOR TEMPERATURE BEFORE LOADING = -128.5 °C VESSEL C.C.T. VOLUME = 136,292.944
ABSOLUTE PRESSURE BEFORE LOADING = 1166 mbar LOADED VOLUME = 135,887.000
5. ENERGY DELIVERED
Q = ( V * D * Hm - Qr ) / 1055.12 With Qr = V * 288.15
*Pa
* 37.707 (Ideal Gas)( 273.15 + Tv ) 1013.25
GROSS QUANTITY = 3,395,916,235 MJ or 3,218,695 MMBTU or 943,310,065 KWH
ENERGY DISPLACED = 11,745,116 MJ or 11,132 MMBTU or 3,262,532 KWH
NET QUANTITY = 3,384,171,119 MJ or 3,207,560 MMBTU or 940,047,533 KWH
6. ADDITIONAL INFORMATION AND COMMENTS
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F.
THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON I.P. PART XII (1998).
THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO GPA 2145 (2000).
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
SPA Contract # 10 LNG-LD-009H1 (07-AUG-09) - 14
m3 / kmole
S ( Xi * Mi )
S ( Xi * Vi ) - Xm * C
Hm (MASS) 15°C
S ( Xi * Mi * Hi ) Hm (MASS) 15°CS ( Xi * Mi )
Hv (VOLUME) 60/60°F at 14.696 PSIA
1.13285 * S ( Xi * Mi * Hi )Hv (VOLUME) 60/60°F at 14.696 PSIA
WOBBE INDEX 60/60°F at 14.696 PSIA
Hv / ÖS ( Xi * Mi ) WOBBE INDEX
60/60°F at 14.696 PSIA
m3
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C A L C U L A T I O N S
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. COMPOSITION FACTORS
MOLAR MOLAR WT. MOLAR VOL. MOLAR HHV
COMPONENTS FRACTION kg / kmole MJ / kg
(Xi) (Mi) (Vi) (Hi)
METHANE 0.9024 16.043 0.038123 55.575
ETHANE 0.0595 30.070 0.047925 51.950
PROPANE 0.0224 44.097 0.062479 50.368
ISO BUTANE 0.0069 58.123 0.078332 49.388
N-BUTANE 0.0058 58.123 0.076856 49.546
ISO PENTANE 0.0002 72.150 0.091699 48.949
N-PENTANE 0.0000 72.150 0.091562 49.045
N-HEXANE 0.0000 86.177 0.104868 48.716
NITROGEN 0.0028 28.013 0.046900 0
CARBON DIOXIDE 0.0000 44.010 0.027183 0
OXYGEN 0.0000 31.9988 0.031474 0
2. DENSITY CALCULATIONS
DENSITY = WITH C = K1 + ( K2 - K1 ) * Xn
0.0425
DENSITY = 459.11 kg/m3 at -160.2 °C K1 = 0.000423 K2 = 0.000682
3. HIGHER HEATING VALUES
= = 54.4361 MJ / kg
= = 1115.3 BTU / SCF
= = 1411.4 BTU / SCF28.9626
4. QUANTITIES DELIVERED
LIQUID TEMPERATURE AFTER LOADING = -160.2 °C VESSEL O.C.T. VOLUME = 404.978
VAPOR TEMPERATURE BEFORE LOADING = -128.5 °C VESSEL C.C.T. VOLUME = 136,292.944
ABSOLUTE PRESSURE BEFORE LOADING = 1166 mbar LOADED VOLUME = 135,887.000
5. ENERGY DELIVERED
GROSS QUANTITY DELIVERED = VOLUME * DENSITY * HHV (MASS BASED) / 1055.12
GROSS DELIVERED QUANTITY = 3,395,911,071 MJ
GROSS DELIVERED QUANTITY = 3,218,690 MMBTU
GROSS DELIVERED QUANTITY = 943,308,631 KWH
6. ADDITIONAL INFORMATION AND COMMENTS
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F.
THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON I.P. PART XII (1998).
THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO GPA 2145 (2000).
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
SPA Contract # 11 LNG-LD-009H1 (07-AUG-09) - 14
m3 / kmole
S ( Xi * Mi )
S ( Xi * Vi ) - Xm * C
Hm (MASS) 15°C
S ( Xi * Mi * Hi ) Hm (MASS) 15°CS ( Xi * Mi )
Hv (VOLUME) 60/60°F at 14.696 PSIA
1.13285 * S ( Xi * Mi * Hi )Hv (VOLUME) 60/60°F at 14.696 PSIA
WOBBE INDEX 60/60°F at 14.696 PSIA
Hv / ÖS ( Xi * Mi ) WOBBE INDEX
60/60°F at 14.696 PSIA
m3
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C A L C U L A T I O N S
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. COMPOSITION FACTORS
MOLAR MOLAR WT. MOLAR VOL. MOLAR HHV
COMPONENTS FRACTION kg / kmole MJ / kg
(Xi) (Mi) (Vi) (Hi)
METHANE 0.9024 16.042 0.038123 55.576
ETHANE 0.0595 30.069 0.047925 51.952
PROPANE 0.0224 44.096 0.062479 50.370
ISO BUTANE 0.0069 58.122 0.078332 49.389
N-BUTANE 0.0058 58.122 0.076856 49.547
ISO PENTANE 0.0002 72.149 0.091699 48.950
N-PENTANE 0.0000 72.149 0.091562 49.046
N-HEXANE 0.0000 86.175 0.104868 48.717
NITROGEN 0.0028 28.013 0.046900 0
CARBON DIOXIDE 0.0000 44.010 0.027183 0
OXYGEN 0.0000 31.9990 0.031474 0
2. DENSITY CALCULATIONS
DENSITY = WITH C = K1 + ( K2 - K1 ) * Xn
0.0425
DENSITY = 459.082 kg/m3 at -160.2 °C K1 = 0.000423 K2 = 0.000682
3. HIGHER HEATING VALUES
= = 54.4372 MJ / kg
= = 1115.2 BTU / SCF
= = 1411.3 BTU / SCF28.9626
4. QUANTITIES DELIVERED
LIQUID TEMPERATURE AFTER LOADING = -160.2 °C VESSEL O.C.T. VOLUME = 404.978
VAPOR TEMPERATURE BEFORE LOADING = -128.5 °C VESSEL C.C.T. VOLUME = 136,292.944
ABSOLUTE PRESSURE BEFORE LOADING = 1166 mbar LOADED VOLUME = 135,888.000
5. ENERGY DELIVERED
GROSS QUANTITY DELIVERED = VOLUME * DENSITY * HHV (MASS BASED) / 1055.12
GROSS DELIVERED QUANTITY = 3,395,805,565 MJ
GROSS DELIVERED QUANTITY = 3,218,590 MMBTU
GROSS DELIVERED QUANTITY = 943,279,324 KWH
6. ADDITIONAL INFORMATION AND COMMENTS
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F.
THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON I.S.O. 6578 (1991).
THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO GPA 2145 (2003).
Mohamed-Hamid BOUABDELLI
FOR INTERTEK FOR TERMINAL FOR VESSEL
SPA Contract # 12 LNG-LD-009H1 (07-AUG-09) - 14
m3 / kmole
S ( Xi * Mi )
S ( Xi * Vi ) - Xm * C
Hm (MASS) 15°C
S ( Xi * Mi * Hi ) Hm (MASS) 15°CS ( Xi * Mi )
Hv (VOLUME) 60/60°F at 14.696 PSIA
1.13285 * S ( Xi * Mi * Hi )Hv (VOLUME) 60/60°F at 14.696 PSIA
WOBBE INDEX 60/60°F at 14.696 PSIA
Hv / ÖS ( Xi * Mi ) WOBBE INDEX
60/60°F at 14.696 PSIA
m3
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C A L C U L A T I O N S
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. COMPOSITION FACTORS
MOLAR MOLAR WT. MOLAR VOL. MOLAR HHV
COMPONENTS FRACTION kg / kmole MJ / kg
(Xi) (Mi) (Vi) (Hi)
METHANE 0.9024 16.043 0.038123 55.575
ETHANE 0.0595 30.070 0.047925 51.950
PROPANE 0.0224 44.097 0.062479 50.368
ISO BUTANE 0.0069 58.123 0.078332 49.388
N-BUTANE 0.0058 58.123 0.076856 49.546
ISO PENTANE 0.0002 72.150 0.091699 48.949
N-PENTANE 0.0000 72.150 0.091562 49.045
N-HEXANE 0.0000 86.177 0.104868 48.716
NITROGEN 0.0028 28.013 0.046900 0
CARBON DIOXIDE 0.0000 44.010 0.027183 0
OXYGEN 0.0000 31.9988 0.031474 0
2. DENSITY CALCULATIONS
DENSITY = WITH C = K1 + ( K2 - K1 ) * Xn
0.0425
DENSITY = 459.11 kg/m3 at -160.2 °C K1 = 0.000423 K2 = 0.000682
3. HIGHER HEATING VALUES
= = 54.4361 MJ / kg
= = 1115.3 BTU / SCF
= = 1411.4 BTU / SCF28.9626
4. QUANTITIES DELIVERED
LIQUID TEMPERATURE AFTER LOADING = -160.2 °C VESSEL O.C.T. VOLUME = 404.978
VAPOR TEMPERATURE BEFORE LOADING = -128.5 °C VESSEL C.C.T. VOLUME = 136,292.944
ABSOLUTE PRESSURE BEFORE LOADING = 1166 mbar LOADED VOLUME = 135,887.000
5. ENERGY DELIVERED
Q = ( V * D * Hm - Qr ) / 1055.12 With Qr = V * 288.15
*Pa
* 37.707 * 0.50( 273.15 + Tv ) 1013.25
GROSS QUANTITY = 3,395,916,235 MJ or 3,218,695 MMBTU or 943,310,065 KWH
ENERGY DISPLACED = 5,872,558 MJ or 5,566 MMBTU or 1,631,266 KWH
NET QUANTITY = 3,390,043,677 MJ or 3,213,120 MMBTU or 941,678,799 KWH
6. ADDITIONAL INFORMATION AND COMMENTS
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F.
THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON I.P. PART XII (1998).
THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO GPA 2145 (2000).
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
SPA Contract # 13 LNG-LD-009H1 (07-AUG-09) - 14
m3 / kmole
S ( Xi * Mi )
S ( Xi * Vi ) - Xm * C
Hm (MASS) 15°C
S ( Xi * Mi * Hi ) Hm (MASS) 15°CS ( Xi * Mi )
Hv (VOLUME) 60/60°F at 14.696 PSIA
1.13285 * S ( Xi * Mi * Hi )Hv (VOLUME) 60/60°F at 14.696 PSIA
WOBBE INDEX 60/60°F at 14.696 PSIA
Hv / ÖS ( Xi * Mi ) WOBBE INDEX
60/60°F at 14.696 PSIA
m3
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C A L C U L A T I O N S
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. COMPOSITION FACTORS
MOLAR MOLAR WT. MOLAR VOL. MOLAR HHV
COMPONENTS FRACTION kg / kmole MJ / kg
(Xi) (Mi) (Vi) (Hi)
METHANE 0.9024 16.043 0.038122 55.575
ETHANE 0.0595 30.070 0.047925 51.95
PROPANE 0.0224 44.097 0.062479 50.368
ISO BUTANE 0.0069 58.123 0.078332 49.388
N-BUTANE 0.0058 58.123 0.076857 49.546
ISO PENTANE 0.0002 72.150 0.091699 48.949
N-PENTANE 0.0000 72.150 0.091562 49.045
N-HEXANE 0.0000 86.177 0.104877 48.716
NITROGEN 0.0028 28.013 0.046866 0
CARBON DIOXIDE 0.0000 44.010 0.027180 0
OXYGEN 0.0000 31.999 0.031474 0
2. DENSITY CALCULATIONS
DENSITY = WITH C = K1 + ( K2 - K1 ) * Xn
0.0425
DENSITY = 459.08 kg/m3 at -160.2 °C K1 = 0.000419 K2 = 0.000685
3. HIGHER HEATING VALUES
= = 54.4361 MJ / kg
= = 1115 BTU / SCF
= = 1411 BTU / SCF28.9626
4. QUANTITIES DELIVERED
LIQUID TEMPERATURE AFTER LOADING = -160.2 °C VESSEL O.C.T. VOLUME = 404.978
VAPOR TEMPERATURE BEFORE LOADING = -128.5 °C VESSEL C.C.T. VOLUME = 136,292.944
ABSOLUTE PRESSURE BEFORE LOADING = 1166 mbar LOADED VOLUME = 135,888.000
5. ENERGY DELIVERED
QUANTITY = V * D * Hm - Qr
WITH Qr = V * 288.15
*Pa
* 37.7 (Ideal Gas)1055.12 ( 273.15 + Tv ) 1013.25
GROSS QUANTITY = 3,395,719,322 MJ or 3,218,508 MMBTU or 943,255,367 KWH
ENERGY DISPLACED = 11,743,022 MJ or 11,130 MMBTU or 3,261,951 KWH
NET QUANTITY = 3,383,978,343 MJ or 3,207,380 MMBTU or 939,993,417 KWH
6. ADDITIONAL INFORMATION AND COMMENTS
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F.
THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON N.B.S. INTERAGENCY REPORT 77-867.
THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO G.P.A. 2145 SI (1989).
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
SPA Contract # 14 LNG-LD-009H1 (07-AUG-09) - 14
m3 / kmole
S ( Xi * Mi )
S ( Xi * Vi ) - Xm * C
Hm (MASS) 15°C
S ( Xi * Mi * Hi ) Hm (MASS) 15°CS ( Xi * Mi )
Hv (VOLUME) 60/60°F at 14.696 psia
S ( Xi * Mi * Hi) * 1.13285Hv (VOLUME) 60/60°F at 14.696 psia
WOBBE INDEX 60/60°F at 14.696 psia
Hv / ÖS ( Xi * Mi ) WOBBE INDEX
60/60°F at 14.696 psia
m3
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C A L C U L A T I O N S
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. COMPOSITION FACTORS
MOLAR MOLAR WT. MOLAR VOL. MOLAR HHV
COMPONENTS FRACTION kg / kmole MJ / kg
(Xi) (Mi) (Vi) (Hi)
METHANE 0.9024 16.043 0.038122 55.575
ETHANE 0.0595 30.070 0.047925 51.95
PROPANE 0.0224 44.097 0.062479 50.368
ISO BUTANE 0.0069 58.123 0.078332 49.388
N-BUTANE 0.0058 58.123 0.076857 49.546
ISO PENTANE 0.0002 72.150 0.091699 48.949
N-PENTANE 0.0000 72.150 0.091562 49.045
N-HEXANE 0.0000 86.177 0.104877 48.716
NITROGEN 0.0028 28.013 0.046866 0
CARBON DIOXIDE 0.0000 44.010 0.027180 0
OXYGEN 0.0000 31.999 0.031474 0
2. DENSITY CALCULATIONS
DENSITY = WITH C = K1 + ( K2 - K1 ) * Xn
0.0425
DENSITY = 459.08 kg/m3 at -160.2 °C K1 = 0.000419 K2 = 0.000685
3. HIGHER HEATING VALUES
= = 54.4361 MJ / kg
= = 1115 BTU / SCF
= = 1411 BTU / SCF28.9626
4. QUANTITIES DELIVERED
LIQUID TEMPERATURE AFTER LOADING = -160.2 °C VESSEL O.C.T. VOLUME = 404.978
VAPOR TEMPERATURE BEFORE LOADING = -128.5 °C VESSEL C.C.T. VOLUME = 136,292.944
ABSOLUTE PRESSURE BEFORE LOADING = 1166 mbar LOADED VOLUME = 135,888.000
5. ENERGY DELIVERED
GROSS QUANTITY DELIVERED = VOLUME * DENSITY * HIGHER HEATING VALUE (MASS BASED) / 1055.12
GROSS DELIVERED QUANTITY = 3,395,721,161 MJ
GROSS DELIVERED QUANTITY = 3,218,510 MMBTU
GROSS DELIVERED QUANTITY = 943,255,878 KWH
6. ADDITIONAL INFORMATION AND COMMENTS
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F.
THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON N.B.S. INTERAGENCY REPORT 77-867.
THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO G.P.A. 2145 SI (1996).
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
SPA Contract # 15 LNG-LD-009H1 (07-AUG-09) - 14
m3 / kmole
S ( Xi * Mi )
S ( Xi * Vi ) - Xm * C
Hm (MASS) 15°C
S ( Xi * Mi * Hi ) Hm (MASS) 15°CS ( Xi * Mi )
Hv (VOLUME) 60/60°F at 14.696 psia
S ( Xi * Mi * Hi) * 1.13285Hv (VOLUME) 60/60°F at 14.696 psia
WOBBE INDEX 60/60°F at 14.696 psia
Hv / ÖS ( Xi * Mi ) WOBBE INDEX
60/60°F at 14.696 psia
m3
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C A L C U L A T I O N S
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. COMPOSITION FACTORS
MOLAR MOLAR WT. MOLAR VOL. MOLAR HHV
COMPONENTS FRACTION kg / kmole MJ / kg
(Xi) (Mi) (Vi) (Hi)
METHANE 0.9024 16.043 0.038123 55.575
ETHANE 0.0595 30.070 0.047925 51.950
PROPANE 0.0224 44.097 0.062479 50.368
ISO BUTANE 0.0069 58.123 0.078332 49.388
N-BUTANE 0.0058 58.123 0.076856 49.546
ISO PENTANE 0.0002 72.150 0.091699 48.949
N-PENTANE 0.0000 72.150 0.091562 49.045
N-HEXANE 0.0000 86.177 0.104868 48.716
NITROGEN 0.0028 28.013 0.046900 0
CARBON DIOXIDE 0.0000 44.010 ----- 0
OXYGEN 0.0000 31.9988 0.031474 0
2. DENSITY CALCULATIONS
DENSITY = WITH C = K1 + ( K2 - K1 ) * Xn
0.0425
DENSITY = 459.08 kg/m3 at -160.2 °C K1 = 0.00042 K2 = 0.00068
3. HIGHER HEATING VALUES
= = 54.4361 MJ / kg
= = 41.63628.314510 * 288.15
= = 52.690028.9626
4. QUANTITIES DELIVERED
LIQUID TEMPERATURE AFTER LOADING = -160.2 °C VESSEL O.C.T. VOLUME = 405
VAPOR TEMPERATURE BEFORE LOADING = -128.5 °C VESSEL C.C.T. VOLUME = 136,293
ABSOLUTE PRESSURE BEFORE LOADING = 116.6 kPa LOADED VOLUME = 135,888
5. ENERGY DELIVERED
QUANTITY = V * D * Hm - Qr WITH Qr = V * 288.15
*Pa
* 37.707 (Ideal Gas)( 273.15 + Tv ) 101.325
GROSS QUANTITY = 3,395,912,432 MJ or 3,218,703 MMBTU or 943,309,009 KWH
ENERGY DISPLACED = 11,745,871 MJ or 11,133 MMBTU or 3,262,742 KWH
NET QUANTITY = 3,384,166,561 MJ or 3,207,570 MMBTU or 940,046,267 KWH
6. ADDITIONAL INFORMATION AND COMMENTS
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 15°C.
THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON I.P. PART XII (1998).
THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO GPA 2145 (2000).
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
SPA Contract # 16 LNG-LD-009H1 (07-AUG-09) - 14
m3 / kmole
S ( Xi * Mi )
S ( Xi * Vi ) - Xm * C
Hm (MASS) 15°C
S ( Xi * Mi * Hi ) Hm (MASS) 15°CS ( Xi * Mi )
Hv (VOLUME) 15/15°C at 101.325 kPa
S ( Xi * Mi * Hi ) * 101.325 Hv (VOLUME) 15/15°C at 101.325 kPa
MJ / m3
WOBBE INDEX 15/15°C at 101.325 kPa
Hv / ÖS ( Xi * Mi ) WOBBE INDEX
15/15°C at 101.325 kPa
MJ / m3
m3
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C A L C U L A T I O N S
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. COMPOSITION FACTORS
MOLAR MOLAR WT. MOLAR VOL. MOLAR HHV
COMPONENTS FRACTION kg / kmole MJ / kg
(Xi) (Mi) (Vi) (Hi)
METHANE 0.9024 16.043 0.038123 55.574
ETHANE 0.0595 30.070 0.047925 51.950
PROPANE 0.0224 44.097 0.062479 50.37
ISO BUTANE 0.0069 58.123 0.078332 49.39
N-BUTANE 0.0058 58.123 0.076856 49.55
ISO PENTANE 0.0002 72.150 0.091699 48.95
N-PENTANE 0.0000 72.150 0.091562 49.04
N-HEXANE 0.0000 86.177 0.104868 48.75
NITROGEN 0.0028 28.0135 0.046900 0
CARBON DIOXIDE 0.0000 44.010 0.027192 0
OXYGEN 0.0000 31.9988 0.031474 0
2. DENSITY CALCULATIONS
DENSITY = WITH C = K1 + ( K2 - K1 ) * Xn
0.0425
DENSITY = 459.11 kg/m3 at -160.2 °C K1 = 0.000423 K2 = 0.000682
3. HIGHER HEATING VALUES
= = 54.4355 MJ / kg
= = 1115 BTU / SCF
= = 1411 BTU / SCF28.9626
4. QUANTITIES DELIVERED
LIQUID TEMPERATURE AFTER LOADING = -160.2 °C VESSEL O.C.T. VOLUME = 404.978
VAPOR TEMPERATURE BEFORE LOADING = -128.5 °C VESSEL C.C.T. VOLUME = 136,292.944
ABSOLUTE PRESSURE BEFORE LOADING = 1166 mbar LOADED VOLUME = 135,888.000
5. ENERGY DELIVERED
Q = ( V * D * Hm - Qr ) / 1055.12 With Qr = V * 273.15
*Pa
* 39.78 (Ideal Gas)( 273.15 + Tv ) 1013.25
GROSS QUANTITY = 3,395,903,795 MJ or 3,218,683 MMBTU or 943,306,610 KWH
ENERGY DISPLACED = 11,745,889 MJ or 11,133 MMBTU or 3,262,747 KWH
NET QUANTITY = 3,384,157,906 MJ or 3,207,550 MMBTU or 940,043,863 KWH
6. ADDITIONAL INFORMATION AND COMMENTS
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F
THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON I.S.O. 6578 (1991).
THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO I.S.O. 6976 (1995).
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
SPA Contract # 17 LNG-LD-009H1 (07-AUG-09) - 14
m3 / kmole
S ( Xi * Mi )
S ( Xi * Vi ) - Xm * C
Hm (MASS) 15°C
S ( Xi * Mi * Hi ) Hm (MASS) 15°CS ( Xi * Mi )
Hv (VOLUME) 60/60°F at 14.696 PSIA
1.13285 * S ( Xi * Mi * Hi )Hv (VOLUME) 60/60°F at 14.696 PSIA
WOBBE INDEX 60/60°F at 14.696 PSIA
Hv / ÖS ( Xi * Mi ) WOBBE INDEX
60/60°F at 14.696 PSIA
m3
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C A L C U L A T I O N S
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. COMPOSITION FACTORS
MOLAR MOLAR WT. MOLAR VOL. MOLAR HHV
COMPONENTS FRACTION kg / kmole MJ / kg
(Xi) (Mi) (Vi) (Hi)
METHANE 0.9024 16.043 0.038122 55.560
ETHANE 0.0595 30.070 0.047925 51.926
PROPANE 0.0224 44.097 0.062479 50.393
ISO BUTANE 0.0069 58.124 0.078332 49.402
N-BUTANE 0.0058 58.124 0.076857 49.544
ISO PENTANE 0.0002 72.151 0.091699 48.944
N-PENTANE 0.0000 72.151 0.091562 49.053
N-HEXANE 0.0000 86.178 0.104877 48.719
NITROGEN 0.0028 28.013 0.046866 0
CARBON DIOXIDE 0.0000 44.010 0.027180 0
OXYGEN 0.0000 31.999 0.031474 0
2. DENSITY CALCULATIONS
DENSITY = WITH C = K1 + ( K2 - K1 ) * Xn
0.0425
DENSITY = 459.08 kg/m3 at -160.2 °C K1 = 0.000419 K2 = 0.000685
3. HIGHER HEATING VALUES
= = 54.4233 MJ / kg
= = 1115 BTU / SCF
= = 1411 BTU / SCF28.9626
4. QUANTITIES DELIVERED
LIQUID TEMPERATURE AFTER LOADING = -160.2 °C VESSEL O.C.T. VOLUME = 404.978
VAPOR TEMPERATURE BEFORE LOADING = -128.5 °C VESSEL C.C.T. VOLUME = 136,292.944
ABSOLUTE PRESSURE BEFORE LOADING = 1166 mbar LOADED VOLUME = 135,888.000
5. ENERGY DELIVERED
Q = ( V * D * Hm - Qr ) / 1055.12 With Qr = V * 288.15
*Pa
* 37.7 (Ideal Gas)( 273.15 + Tv ) 1013.25
GROSS QUANTITY = 3,394,920,859 MJ or 3,217,751 MMBTU or 943,033,572 KWH
ENERGY DISPLACED = 11,743,022 MJ or 11,130 MMBTU or 3,261,951 KWH
NET QUANTITY = 3,383,177,837 MJ or 3,206,621 MMBTU or 939,771,621 KWH
6. ADDITIONAL INFORMATION AND COMMENTS
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F
THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON N.B.S. INTERAGENCY REPORT 77-867.
THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO I.P. 251/76.
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
SPA Contract # 18 LNG-LD-009H1 (07-AUG-09) - 14
m3 / kmole
S ( Xi * Mi )
S ( Xi * Vi ) - Xm * C
Hm (MASS) 15°C
S ( Xi * Mi * Hi ) Hm (MASS) 15°CS ( Xi * Mi )
Hv (VOLUME) 60/60°F at 14.696 PSIA
1.13285 * S ( Xi * Mi * Hi )Hv (VOLUME) 60/60°F at 14.696 PSIA
WOBBE INDEX 60/60°F at 14.696 PSIA
Hv / ÖS ( Xi * Mi ) WOBBE INDEX
60/60°F at 14.696 PSIA
m3
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
R E P O R T O F C A L C U L A T I O N S
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. COMPOSITION FACTORS
MOLAR MOLAR WT. MOLAR VOL. MOLAR HHV
COMPONENTS FRACTION kg / kmol MJ / kmol
(Xi) (Mi) (Vi) (Hi)
METHANE 0.902400 16.043 0.038123 891.56
ETHANE 0.059500 30.070 0.047925 1562.14
PROPANE 0.022400 44.097 0.062479 2221.1
ISO BUTANE 0.006900 58.123 0.078332 2870.58
N-BUTANE 0.005800 58.123 0.076856 2879.76
ISO PENTANE 0.000200 72.150 0.091699 3531.68
N-PENTANE 0.000000 72.150 0.091562 3538.6
N-HEXANE 0.000000 86.177 0.104868 4198.24
NITROGEN 0.002800 28.014 0.046900 0
OXYGEN 0.000000 31.999 0.031474 0
2. DENSITY CALCULATIONS
DENSITY = WITH C = K1 + ( K2 - K1 ) * Xn
0.0425
DENSITY = 459.10 kg/m3 at -160.2 °C K1 = 0.000423 K2 = 0.000682
3. HIGHER HEATING VALUES
= = 54.4346 MJ / kg
= = 41.63518.314510 * 288.15
= = 52.688628.9626
4. QUANTITIES DELIVERED
LIQUID TEMPERATURE AFTER LOADING = -160.2 °C VESSEL O.C.T. VOLUME = 404.978
VAPOR TEMPERATURE BEFORE LOADING = -128.0 °C VESSEL C.C.T. VOLUME = 136,292.944
ABSOLUTE PRESSURE BEFORE LOADING = 1166 mbar LOADED VOLUME = 135,888.000
5. ENERGY DELIVERED
QUANTITY = V * D * Hm - Qr WITH Qr = V * ( 273.15 + 15 )
*Pa
* 37.7 (Ideal Gas)( 273.15 + Tv ) 1013.25
GROSS QUANTITY = 3,395,968,923 MJ or 3,218,745 MMBTU or 943,324,701 KWH
ENERGY DISPLACED = 11,703,236 MJ or 11,092 MMBTU or 3,250,899 KWH
NET QUANTITY = 3,384,265,686 MJ or 3,207,650 MMBTU or 940,073,802 KWH
6. ADDITIONAL INFORMATION AND COMMENTS
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 15°C.
THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON I.S.O. 6578 (1991).
THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO I.S.O. 6976 (1995).
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
SPA Contract # 19 LNG-LD-009H1 (07-AUG-09) - 14
m3 / kmol
S ( Xi * Mi )
S ( Xi * Vi ) - Xm * C
Hm (MASS) 15°C
S ( Xi * Hi ) Hm (MASS) 15°CS ( Xi * Mi )
Hv (VOLUME) 15/15°C at 101.325 kPa
S ( Xi * Hi ) * 101.325 Hv (VOLUME) 15/15°C at 101.325 kPa
MJ / m3
WOBBE INDEX 15/15°C at 101.325 kPa
Hv / ÖS ( Xi * Mi ) WOBBE INDEX
15/15°C at 101.325 kPa
MJ / m3
m3
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
O P E N I N G C U S T O D Y T R A N S F E R
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TIME : 10:28
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. OPENING CUSTODY TRANSFER MEASUREMENTS
TANK NAME 1 2 3 4
SYSTEM TYPE PRIMARY PRIMARY PRIMARY PRIMARY
1ST READING m 0.035 0.033 0.033 0.287
2ND READING m 0.035 0.032 0.033 0.297
3RD READING m 0.035 0.032 0.033 0.290
4TH READING m 0.035 0.033 0.033 0.290
5TH READING m 0.035 0.032 0.032 0.290
AVG. GAUGE m 0.035 0.032 0.033 0.291
DENSITY CORR. m 0.000 0.000 0.000 0.000
TEMP. CORR. m 0.000 0.000 0.000 0.000
TRIM CORR. m -0.003 -0.004 -0.004 -0.011
LIST CORR. m 0.007 0.010 0.010 0.000
CORR. GAUGE m 0.039 0.038 0.039 0.280
2. OPENING CUSTODY TRANSFER TEMPERATURES
TANK NAME 1 2 3 4
TEMP PROBE #1 °C -119.60 V -123.00 V -123.10 V -118.20 V
TEMP PROBE #2 °C -127.10 V -126.90 V -127.20 V -125.40 V
TEMP PROBE #3 °C -129.60 V -129.00 V -129.10 V -129.00 V
TEMP PROBE #4 °C -132.40 V -131.40 V -131.80 V -133.60 V
TEMP PROBE #5 °C -133.10 V -131.90 V -132.30 V -136.10 V
TEMP PROBE #6 °C -143.20 L -141.50 L -142.20 L -157.90 L
TANK AVERAGE °C -128.36 V -128.44 V -128.70 V -128.46 V
TANK AVERAGE °C -143.20 L -141.50 L -142.20 L -157.90 L
AVERAGE VAPOR TEMPERATURE = -128.5 °C AVERAGE LIQUID TEMPERATURE = -146.2 °C
3. OPENING CUSTODY TRANSFER PRESSURES
TANK NAME 1 2 3 4
PRESSURE 1166 1166 1166 1166
AVERAGE TANK PRESSURE = 1166 mbar ATMOSPHERIC PRESSURE = 998 mbar
4. OPENING CUSTODY TRANSFER VOLUMES
TANK NAME 1 2 3 4
TANK VOLUME 21.371 37.771 38.761 307.075
THERMAL CORR. 1.000000 1.000000 1.000000 1.000000
CORR. VOLUME 21.371 37.771 38.761 307.075
OPENING CUSTODY TRANSFER VOLUME = 404.978 CUBIC METERS
5. ADDITION INFORMATION AND COMMENTS
FWD DRAFT = 9.60 m TRIM = 0.18 m VESSEL DECK LINES = EMPTY
AFT DRAFT = 9.78 m LIST = 0.21 °P
Mohamed-Hamid BOUABDELLI
FOR INTERTEK FOR TERMINAL FOR VESSEL
Arrival Inspection LNG-LD-009H1 (07-AUG-09) - 14
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
A F T E R G A S - U P M E A S U R E M E N T
VESSEL : SK SPLENDOR DATE : 7-Aug-2009 TIME : 03:05
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. OPENING CUSTODY TRANSFER MEASUREMENTS
TANK NAME 1 2 3 4
SYSTEM TYPE PRIMARY PRIMARY PRIMARY PRIMARY
1ST READING m 0.000 0.000 0.000 0.000
2ND READING m 0.000 0.000 0.000 0.000
3RD READING m 0.000 0.000 0.000 0.000
4TH READING m 0.000 0.000 0.000 0.000
5TH READING m 0.000 0.000 0.000 0.000
AVG. GAUGE m 0.000 0.000 0.000 0.000
DENSITY CORR. m 0.000 0.000 0.000 0.000
TEMP. CORR. m 0.000 0.000 0.000 0.000
TRIM CORR. m 0.000 0.000 0.000 0.000
LIST CORR. m 0.000 0.000 0.000 0.000
CORR. GAUGE m 0.000 0.000 0.000 0.000
2. OPENING CUSTODY TRANSFER TEMPERATURES
TANK NAME 1 2 3 4
TEMP PROBE #1 °C 24.02 V 23.77 V 23.99 V 25.22 V
TEMP PROBE #2 °C 23.91 V 23.52 V 23.67 V 25.10 V
TEMP PROBE #3 °C 23.93 V 23.50 V 23.63 V 25.13 V
TEMP PROBE #4 °C 23.80 V 23.49 V 23.64 V 24.99 V
TEMP PROBE #5 °C 23.74 V 23.37 V 23.52 V 24.90 V
TEMP PROBE #6 °C
TANK AVERAGE °C 23.88 V 23.53 V 23.69 V 25.07 V
TANK AVERAGE °C
AVERAGE VAPOR TEMPERATURE = 24.0 °C AVERAGE LIQUID TEMPERATURE = °C
3. OPENING CUSTODY TRANSFER PRESSURES
TANK NAME 1 2 3 4
PRESSURE 1172 1171 1172 1169
AVERAGE TANK PRESSURE = 1171 mbar ATMOSPHERIC PRESSURE = 1008 mbar
4. OPENING CUSTODY TRANSFER VOLUMES
TANK NAME 1 2 3 4
TANK VOLUME 0.000 0.000 0.000 0.000
THERMAL CORR. 1.000000 1.000000 1.000000 1.000000
CORR. VOLUME 0.000 0.000 0.000 0.000
OPENING CUSTODY TRANSFER VOLUME = 0.000 CUBIC METERS
5. ADDITION INFORMATION AND COMMENTS
FWD DRAFT = 9.00 m TRIM = 0.20 m VESSEL DECK LINES = EMPTY
AFT DRAFT = 9.20 m LIST = 0.00
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
After Gas Up Inspection LNG-LD-009H1 (07-AUG-09) - 14
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
A F T E R C O O L - D O W N M E A S U R E M E N T
VESSEL : SK SPLENDOR DATE : 7-Aug-2009 TIME : 12:03
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. AFTER COOL DOWN MEASUREMENTS
TANK NAME 1 2 3 4
SYSTEM TYPE PRIMARY PRIMARY PRIMARY PRIMARY
1ST READING m 0.069 0.027 0.042 0.044
2ND READING m 0.069 0.027 0.042 0.044
3RD READING m 0.069 0.027 0.042 0.044
4TH READING m 0.069 0.027 0.042 0.044
5TH READING m 0.069 0.027 0.042 0.044
AVG. GAUGE m 0.069 0.027 0.042 0.044
DENSITY CORR. m 0.000 0.000 0.000 0.000
TEMP. CORR. m 0.000 0.000 0.000 0.000
TRIM CORR. m -0.004 -0.003 -0.005 -0.004
LIST CORR. m 0.005 0.010 0.009 0.006
CORR. GAUGE m 0.070 0.034 0.046 0.046
2. AFTER COOL DOWN TEMPERATURES
TANK NAME 1 2 3 4
TEMP PROBE #1 °C -122.00 V -119.20 V -118.90 V -119.40 V
TEMP PROBE #2 °C -124.20 V -122.00 V -121.90 V -122.30 V
TEMP PROBE #3 °C -125.70 V -124.50 V -124.60 V -124.70 V
TEMP PROBE #4 °C -127.70 V -126.30 V -126.60 V -126.60 V
TEMP PROBE #5 °C -127.70 V -126.90 V -127.60 V -126.90 V
TEMP PROBE #6 °C -158.50 L -155.10 L -158.30 L -158.80 L
TANK AVERAGE °C -125.46 V -123.78 V -123.92 V -123.98 V
TANK AVERAGE °C -158.50 L -155.10 L -158.30 L -158.80 L
AVERAGE VAPOR TEMPERATURE = -124.3 °C AVERAGE LIQUID TEMPERATURE = -157.7 °C
3. AFTER COOL DOWN PRESSURES
TANK NAME 1 2 3 4
PRESSURE 1069 1070 1070 1070
AVERAGE TANK PRESSURE = 1069.75 mbar ATMOSPHERIC PRESSURE = 998 mbar
4. AFTER COOL DOWN VOLUMES
TANK NAME 1 2 3 4
TANK VOLUME 47.856 44.726 60.576 59.168
THERMAL CORR. 1.000000 1.000000 1.000000 1.000000
CORR. VOLUME 47.856 44.726 60.576 59.168
AFTER COOL DOWN VOLUME = 212.326 CUBIC METERS
5. ADDITION INFORMATION AND COMMENTS
FWD DRAFT = 9.45 m TRIM = 0.16 m VESSEL DECK LINES = EMPTY
AFT DRAFT = 9.61 m LIST = 0.15 °P
Data from Snapshot CTS
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
After Cool Down Inspection LNG-LD-009H1 (07-AUG-09) - 14
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
C L O S I N G C U S T O D Y T R A N S F E R
VESSEL : SK SPLENDOR DATE : 5-Aug-2009 TIME : 04:17
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. CLOSING CUSTODY TRANSFER MEASUREMENTS
TANK NAME 1 2 3 4
SYSTEM TYPE PRIMARY PRIMARY PRIMARY PRIMARY
1ST READING m 26.360 26.236 26.257 26.232
2ND READING m 26.355 26.250 26.241 26.251
3RD READING m 26.385 26.243 26.242 26.243
4TH READING m 26.355 26.254 26.236 26.243
5TH READING m 26.393 26.250 26.248 26.237
AVG. GAUGE m 26.370 26.247 26.245 26.241
DENSITY CORR. m 0.000 0.000 0.000 0.000
TEMP. CORR. m 0.000 0.000 0.000 0.000
TRIM CORR. m -0.030 -0.042 -0.042 -0.036
LIST CORR. m 0.000 0.001 0.000 0.000
CORR. GAUGE m 26.340 26.206 26.203 26.205
2. CLOSING CUSTODY TRANSFER TEMPERATURES
TANK NAME 1 2 3 4
TEMP PROBE #1 °C -145.40 V -155.00 V -155.10 V -152.40 V
TEMP PROBE #2 °C -160.20 L -160.20 L -160.20 L -160.30 L
TEMP PROBE #3 °C -160.20 L -160.30 L -160.20 L -160.30 L
TEMP PROBE #4 °C -160.20 L -160.30 L -160.30 L -160.20 L
TEMP PROBE #5 °C -160.20 L -160.20 L -160.20 L -160.20 L
TEMP PROBE #6 °C -160.30 L -160.30 L -160.20 L -160.30 L
TANK AVERAGE °C -145.40 V -155.00 V -155.10 V -152.40 V
TANK AVERAGE °C -160.22 L -160.26 L -160.22 L -160.26 L
AVERAGE VAPOR TEMPERATURE = -152.0 °C AVERAGE LIQUID TEMPERATURE = -160.2 °C
3. CLOSING CUSTODY TRANSFER PRESSURES
TANK NAME 1 2 3 4
PRESSURE 1101 1101 1102 1102
AVERAGE TANK PRESSURE = 1101.5 mbar ATMOSPHERIC PRESSURE = 990 mbar
4. CLOSING CUSTODY TRANSFER VOLUMES
TANK NAME 1 2 3 4
TANK VOLUME 24,159.419 38,797.660 38,818.221 34,517.644
THERMAL CORR. 1.000000 1.000000 1.000000 1.000000
CORR. VOLUME 24,159.419 38,797.660 38,818.221 34,517.644
CLOSING CUSTODY TRANSFER VOLUME = 136,292.944 CUBIC METERS
5. ADDITION INFORMATION AND COMMENTS
FWD DRAFT = 11.45 m TRIM = 0.05 m VESSEL DECK LINES = FULL
AFT DRAFT = 11.50 m LIST = 0.34 °P
SAMPLES FOR OMAN LNG TESTING WERE SEALED (# 046725 / # 046769
SAMPLES FOR OMAN LNG RETAIN WERE SEALED (# 046797 / # 046736)
SAMPLES FOR SHIP SEALED (# 046707 / # 046761)
DRY LINES OF GC WERE DONE BEFORE START FIRST STANDARD GAS INJECTION
Mohamed-Hamid BOUABDELLI
FOR INTERTEK FOR TERMINAL FOR VESSEL
Departure Inspection LNG-LD-009H1 (07-AUG-09) - 14
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
S E C O N D A R Y C U S T O D Y T R A N S F E R
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. OPENING SECONDARY CUSTODY TRANSFER MEASUREMENTS
TANK NAME 1 2 3 4
1ST READING m 0.039 0.037 0.039 0.289
2ND READING m 0.035 0.038 0.037 0.290
3RD READING m 0.040 0.038 0.037 0.290
4TH READING m 0.039 0.036 0.037 0.295
5TH READING m 0.039 0.036 0.039 0.295
AVG. GAUGE m 0.038 0.037 0.038 0.292
DENSITY CORR. m 0.000 0.000 0.000 0.000
TEMP. CORR. m 0.000 0.000 0.000 0.000
TRIM CORR. m -0.004 -0.004 -0.005 -0.012
LIST CORR. m 0.009 0.012 0.012 0.003
CORR. GAUGE m 0.043 0.045 0.045 0.283
2. OPENING SECONDARY CUSTODY TRANSFER VOLUMES
TANK NAME 1 2 3 4
TANK VOLUME 23.611 44.882 44.875 310.528
THERMAL CORR. 1.000000 1.000000 1.000000 1.000000
CORR. VOLUME 23.611 44.882 44.875 310.528
OPENING SECONDARY CUSTODY TRANSFER VOLUME = 423.896 CUBIC METERS
OPENING CUSTODY TRANSFER VOLUME = 404.978 CUBIC METERS
DIFFERENCE = 18.918 CUBIC METERS
3. CLOSING SECONDARY CUSTODY TRANSFER MEASUREMENTS
TANK NAME 1 2 3 4
1ST READING m 26.366 26.249 26.250 26.254
2ND READING m 26.367 26.256 26.253 26.256
3RD READING m 26.372 26.254 26.249 26.256
4TH READING m 26.368 26.253 26.248 26.256
5TH READING m 26.369 26.250 26.248 26.255
AVG. GAUGE m 26.368 26.252 26.250 26.255
DENSITY CORR. m 0.000 0.000 0.000 0.000
TEMP. CORR. m 0.000 0.000 0.000 0.000
TRIM CORR. m -0.035 -0.047 -0.047 -0.044
LIST CORR. m 0.005 0.005 0.005 0.005
CORR. GAUGE m 26.338 26.210 26.208 26.216
4. CLOSING SECONDARY CUSTODY TRANSFER VOLUMES
TANK NAME 1 2 3 4
TANK VOLUME 24,157.993 38,801.440 38,822.552 34,526.897
THERMAL CORR. 1.000000 1.000000 1.000000 1.000000
CORR. VOLUME 24,157.993 38,801.440 38,822.552 34,526.897
CLOSING SECONDARY CUSTODY TRANSFER VOLUME = 136,308.882 CUBIC METERS
CLOSING CUSTODY TRANSFER VOLUME = 136,292.944 CUBIC METERS
DIFFERENCE = 15.938 CUBIC METERS
5. ADDITION INFORMATION AND COMMENTS
SEA CONDITION : ROLLING
Mohamed-Hamid BOUABDELLI
FOR INTERTEK FOR TERMINAL FOR VESSEL
LNG-LD-009H1 (07-AUG-09) - 14
m3
m3
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
V E S S E L M E A S U R E M E N T - R E F E R E N C E O N L Y
VESSEL : SK SPLENDOR DATE : 5-Jun-2007 TIME : 06:07
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. VESSEL TANK MEASUREMENTS
TANK NAME 1 2 3 4
SYSTEM TYPE PRIMARY PRIMARY PRIMARY PRIMARY
1ST READING m 0.000 0.000 0.000 0.000
2ND READING m 0.000 0.000 0.000 0.000
3RD READING m 0.000 0.000 0.000 0.000
4TH READING m 0.000 0.000 0.000 0.000
5TH READING m 0.000 0.000 0.000 0.000
AVG. GAUGE m 0.000 0.000 0.000 0.000
DENSITY CORR. m 0.000 0.000 0.000 0.000
TEMP. CORR. m 0.000 0.000 0.000 0.000
TRIM CORR. m 0.000 0.000 0.000 0.000
LIST CORR. m 0.000 0.000 0.000 0.000
CORR. GAUGE m 0.000 0.000 0.000 0.000
2. VESSEL TANK TEMPERATURES
TANK NAME 1 2 3 4
TEMP PROBE #1 °C 29.76 V 30.08 V 29.44 V 29.70 V
TEMP PROBE #2 °C 29.46 V 29.78 V 29.18 V 29.61 V
TEMP PROBE #3 °C 29.08 V 29.25 V 28.80 V 29.48 V
TEMP PROBE #4 °C 29.28 V 29.26 V 28.67 V 29.48 V
TEMP PROBE #5 °C 28.71 V 29.12 V 28.65 V 29.33 V
TEMP PROBE #6 °C
TANK AVERAGE °C 29.26 V 29.50 V 28.95 V 29.52 V
TANK AVERAGE °C
AVERAGE VAPOR TEMPERATURE = 29.3 °C AVERAGE LIQUID TEMPERATURE = °C
3. VESSEL TANK PRESSURES
TANK NAME 1 2 3 4
PRESSURE 1106 1107 1106 1107
AVERAGE TANK PRESSURE = 1106.5 mbar ATMOSPHERIC PRESSURE = 992 mbar
4. VESSEL TANK VOLUMES
TANK NAME 1 2 3 4
TANK VOLUME 0.000 0.000 0.000 0.000
THERMAL CORR. 1.000000 1.000000 1.000000 1.000000
CORR. VOLUME 0.000 0.000 0.000 0.000
VESSEL VOLUME = 0.000 CUBIC METERS
5. ADDITION INFORMATION AND COMMENTS
FWD DRAFT = 9.00 m TRIM = 0.02 m VESSEL DECK LINES = EMPTY
AFT DRAFT = 9.02 m LIST = 0.02 °S
ABDELOUAHEB ZENNIR
FOR INTERTEK FOR TERMINAL FOR VESSEL
Vessel Measurement 1 LNG-LD-009H1 (07-AUG-09) - 14
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
V E S S E L M E A S U R E M E N T - R E F E R E N C E O N L Y
VESSEL : SK SPLENDOR DATE : 5-Jun-2007 TIME : 06:07
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. VESSEL TANK MEASUREMENTS
TANK NAME 1 2 3 4
SYSTEM TYPE PRIMARY PRIMARY PRIMARY PRIMARY
1ST READING m 0.000 0.000 0.000 0.000
2ND READING m 0.000 0.000 0.000 0.000
3RD READING m 0.000 0.000 0.000 0.000
4TH READING m 0.000 0.000 0.000 0.000
5TH READING m 0.000 0.000 0.000 0.000
AVG. GAUGE m 0.000 0.000 0.000 0.000
DENSITY CORR. m 0.000 0.000 0.000 0.000
TEMP. CORR. m 0.000 0.000 0.000 0.000
TRIM CORR. m 0.000 0.000 0.000 0.000
LIST CORR. m 0.000 0.000 0.000 0.000
CORR. GAUGE m 0.000 0.000 0.000 0.000
2. VESSEL TANK TEMPERATURES
TANK NAME 1 2 3 4
TEMP PROBE #1 °C 29.76 V 30.08 V 29.44 V 29.70 V
TEMP PROBE #2 °C 29.46 V 29.78 V 29.18 V 29.61 V
TEMP PROBE #3 °C 29.08 V 29.25 V 28.80 V 29.48 V
TEMP PROBE #4 °C 29.28 V 29.26 V 28.67 V 29.48 V
TEMP PROBE #5 °C 28.71 V 29.12 V 28.65 V 29.33 V
TEMP PROBE #6 °C
TANK AVERAGE °C 29.26 V 29.50 V 28.95 V 29.52 V
TANK AVERAGE °C
AVERAGE VAPOR TEMPERATURE = 29.3 °C AVERAGE LIQUID TEMPERATURE = °C
3. VESSEL TANK PRESSURES
TANK NAME 1 2 3 4
PRESSURE 1106 1107 1106 1107
AVERAGE TANK PRESSURE = 1106.5 mbar ATMOSPHERIC PRESSURE = 992 mbar
4. VESSEL TANK VOLUMES
TANK NAME 1 2 3 4
TANK VOLUME 0.000 0.000 0.000 0.000
THERMAL CORR. 1.000000 1.000000 1.000000 1.000000
CORR. VOLUME 0.000 0.000 0.000 0.000
VESSEL VOLUME = 0.000 CUBIC METERS
5. ADDITION INFORMATION AND COMMENTS
FWD DRAFT = 9.00 m TRIM = 0.02 m VESSEL DECK LINES = EMPTY
AFT DRAFT = 9.02 m LIST = 0.02 °S
ABDELOUAHEB ZENNIR
FOR INTERTEK FOR TERMINAL FOR VESSEL
Vessel Measurement 2 LNG-LD-009H1 (07-AUG-09) - 14
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
V E S S E L M E A S U R E M E N T - R E F E R E N C E O N L Y
VESSEL : SK SPLENDOR DATE : 5-Jun-2007 TIME : 06:07
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. VESSEL TANK MEASUREMENTS
TANK NAME 1 2 3 4
SYSTEM TYPE PRIMARY PRIMARY PRIMARY PRIMARY
1ST READING m 0.000 0.000 0.000 0.000
2ND READING m 0.000 0.000 0.000 0.000
3RD READING m 0.000 0.000 0.000 0.000
4TH READING m 0.000 0.000 0.000 0.000
5TH READING m 0.000 0.000 0.000 0.000
AVG. GAUGE m 0.000 0.000 0.000 0.000
DENSITY CORR. m 0.000 0.000 0.000 0.000
TEMP. CORR. m 0.000 0.000 0.000 0.000
TRIM CORR. m 0.000 0.000 0.000 0.000
LIST CORR. m 0.000 0.000 0.000 0.000
CORR. GAUGE m 0.000 0.000 0.000 0.000
2. VESSEL TANK TEMPERATURES
TANK NAME 1 2 3 4
TEMP PROBE #1 °C 29.76 V 30.08 V 29.44 V 29.70 V
TEMP PROBE #2 °C 29.46 V 29.78 V 29.18 V 29.61 V
TEMP PROBE #3 °C 29.08 V 29.25 V 28.80 V 29.48 V
TEMP PROBE #4 °C 29.28 V 29.26 V 28.67 V 29.48 V
TEMP PROBE #5 °C 28.71 V 29.12 V 28.65 V 29.33 V
TEMP PROBE #6 °C
TANK AVERAGE °C 29.26 V 29.50 V 28.95 V 29.52 V
TANK AVERAGE °C
AVERAGE VAPOR TEMPERATURE = 29.3 °C AVERAGE LIQUID TEMPERATURE = °C
3. VESSEL TANK PRESSURES
TANK NAME 1 2 3 4
PRESSURE 1106 1107 1106 1107
AVERAGE TANK PRESSURE = 1106.5 mbar ATMOSPHERIC PRESSURE = 992 mbar
4. VESSEL TANK VOLUMES
TANK NAME 1 2 3 4
TANK VOLUME 0.000 0.000 0.000 0.000
THERMAL CORR. 1.000000 1.000000 1.000000 1.000000
CORR. VOLUME 0.000 0.000 0.000 0.000
VESSEL VOLUME = 0.000 CUBIC METERS
5. ADDITION INFORMATION AND COMMENTS
FWD DRAFT = 9.00 m TRIM = 0.02 m VESSEL DECK LINES = EMPTY
AFT DRAFT = 9.02 m LIST = 0.02 °S
ABDELOUAHEB ZENNIR
FOR INTERTEK FOR TERMINAL FOR VESSEL
Vessel Measurement 3 LNG-LD-009H1 (07-AUG-09) - 14
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
V E S S E L M E A S U R E M E N T - R E F E R E N C E O N L Y
VESSEL : SK SPLENDOR DATE : 5-Jun-2007 TIME : 06:07
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. VESSEL TANK MEASUREMENTS
TANK NAME 1 2 3 4
SYSTEM TYPE PRIMARY PRIMARY PRIMARY PRIMARY
1ST READING m 0.000 0.000 0.000 0.000
2ND READING m 0.000 0.000 0.000 0.000
3RD READING m 0.000 0.000 0.000 0.000
4TH READING m 0.000 0.000 0.000 0.000
5TH READING m 0.000 0.000 0.000 0.000
AVG. GAUGE m 0.000 0.000 0.000 0.000
DENSITY CORR. m 0.000 0.000 0.000 0.000
TEMP. CORR. m 0.000 0.000 0.000 0.000
TRIM CORR. m 0.000 0.000 0.000 0.000
LIST CORR. m 0.000 0.000 0.000 0.000
CORR. GAUGE m 0.000 0.000 0.000 0.000
2. VESSEL TANK TEMPERATURES
TANK NAME 1 2 3 4
TEMP PROBE #1 °C 29.76 V 30.08 V 29.44 V 29.70 V
TEMP PROBE #2 °C 29.46 V 29.78 V 29.18 V 29.61 V
TEMP PROBE #3 °C 29.08 V 29.25 V 28.80 V 29.48 V
TEMP PROBE #4 °C 29.28 V 29.26 V 28.67 V 29.48 V
TEMP PROBE #5 °C 28.71 V 29.12 V 28.65 V 29.33 V
TEMP PROBE #6 °C
TANK AVERAGE °C 29.26 V 29.50 V 28.95 V 29.52 V
TANK AVERAGE °C
AVERAGE VAPOR TEMPERATURE = 29.3 °C AVERAGE LIQUID TEMPERATURE = °C
3. VESSEL TANK PRESSURES
TANK NAME 1 2 3 4
PRESSURE 1106 1107 1106 1107
AVERAGE TANK PRESSURE = 1106.5 mbar ATMOSPHERIC PRESSURE = 992 mbar
4. VESSEL TANK VOLUMES
TANK NAME 1 2 3 4
TANK VOLUME 0.000 0.000 0.000 0.000
THERMAL CORR. 1.000000 1.000000 1.000000 1.000000
CORR. VOLUME 0.000 0.000 0.000 0.000
VESSEL VOLUME = 0.000 CUBIC METERS
5. ADDITION INFORMATION AND COMMENTS
FWD DRAFT = 9.00 m TRIM = 0.02 m VESSEL DECK LINES = EMPTY
AFT DRAFT = 9.02 m LIST = 0.02 °S
ABDELOUAHEB ZENNIR
FOR INTERTEK FOR TERMINAL FOR VESSEL
Vessel Measurement 4 LNG-LD-009H1 (07-AUG-09) - 14
m3
m3
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
G E N E R A L I N F O R M A T I O N
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. VESSEL - CUSTODY TRANSFER MEASUREMENT SYSTEMS
VESSEL TANK DESIGN TYPE : MEMBRANE NUMBER OF TANKS : 4
PRIMARY GAUGING DEVICE MAKE : FOXBORO TYPE : RADAR
SECONDARY GAUGING DEVICE MAKE : WHESSOE TYPE : FLOAT
TEMPERATURE DEVICE MAKE : FOXBORO NUMBER PER TANK : 6
PRESSURE DEVICE MAKE : FOXBORO RANGE : 800 MBAR TO 1400 MBAR
2. VESSEL - CARGO TANK CAPACITY & TEMPERATURE PROBE HEIGHT PROFILES
TANK NAME 1 2 3 4
GAUGE HEIGHT m 41.491 41.509 41.511 41.498
TANK CAPACITY 37,326.000 37,336.000 37,352.000 37,345.000
TEMP PROBE #1 26.586 26.471 26.495 26.496
TEMP PROBE #2 25.525 25.604 25.520 25.517
TEMP PROBE #3 22.847 22.839 22.849 22.844
TEMP PROBE #4 13.480 13.432 13.482 13.475
TEMP PROBE #5 6.791 6.776 6.794 6.789
TEMP PROBE #6 0.025 0.025 0.026 0.025
3. VESSEL - CARGO QUANTITY CONSUMED AS FUEL BY VESSEL
METER I.D. O.C.T. READING C.C.T. READING OBSERVED CONDITIONS APPLY
1. ENGINE ROOM OP : 0 kg CL : 0 kg MASS BASED CALCS YES
2.
3.
4.
5.
6.
7.
THE ENERGY OF GAS CONSUMED AS FUEL IS BASED ON : THE HIGHER HEATING VALUE OF LNG CARGO
4. TERMINAL - GAS CHROMATOGRAPHY EQUIPMENT
TESTING EQUIPMENT MAKE : AC.AGILENT MODEL : 6890
CERTIFIED REFERENCE GAS SUPPLIER : SCOTT GAS SERIAL # : 7800102
GC VERIFICATION BEFORE : YES AFTER : NO
5. TERMINAL - PRIMARY SAMPLING SYSTEM
SAMPLE COLLECTOR : GAS SAMPLE HOLDER SAMPLING SYSTEM TYPE : CONTINUOUS
# OF SAMPLES PER SET : 3 SIZE OF SAMPLE : 2250 cc
FREQUENCY OF SAMPLING : SAMPLED AFTER COMPLETION OF BULK LOADING
6. TERMINAL - SHORE STORAGE & CAPACITY
TANKS 1 2
TANK ID # T 3101 T 3102
135,000 135,000
7. ADDITION INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
LNG-LD-009H1 (07-AUG-09) - 14
m3
CAPACITY (M3)
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
O P E R A T I O N A L C H E C K L I S T
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. SHORE OPERATIONS - PRIOR TO LOAD
DID THE TERMINAL SUPPLY A CURRENT REPORT OF CALIBRATION FOR THE GC ? YES
WAS THE GC VERIFIED AGAINST A CERTIFIED REFERENCE GAS PRIOR TO LOADING / USAGE ? YES
DOES THE CERTIFIED REFERENCE GAS HAVE A CURRENT CERTIFICATE OF CALIBRATION ? YES
2. VESSEL OPERATIONS - ON ARRIVAL
ARE ALL PRIMARY CUSTODY GAUGING DEVISES OPERATIONAL ON ARRIVAL ? YES
DOES THE PRIMARY SYSTEM HAVE A CURRENT CERTIFICATE OF CALIBRATION ? YES
ARE ALL SECONDARY CUSTODY GAUGING DEVISES OPERATIONAL ON ARRIVAL ? YES
DOES THE SECONDARY SYSTEM HAVE A CURRENT CERTIFICATE OF CALIBRATION ? YES
ARE ALL CUSTODY REMOTE TEMPERATURE DEVISES OPERATIONAL ON ARRIVAL ? YES
DOES THE TEMPERATURE SYSTEM HAVE A CURRENT CERTIFICATE OF CALIBRATION ? YES
ARE ALL CUSTODY PRESSURE DEVISES OPERATIONAL ON ARRIVAL ? YES
DOES THE PRESSURE SYSTEM HAVE A CURRENT CERTIFICATE OF CALIBRATION ? YES
WERE THE TANKS "BOTTLED UP" DURING OPENING CUSTODY TRANSFER MEASUREMENT ? YES
DOES THE VESSEL HAVE CURRENT CERTIFIED TANK STRAPPING TABLES ? YES
ARE THE TANK STRAPPING TABLES WRITTEN IN ENGLISH ? YES
DOES THE TANK STRAPPING TABLES EXPLAIN HOW TO UTILIZED THE TABLES ? YES
DOES THE TANK STRAPPING TABLES HAVE GAUGE CORRECTION FACTORS (TRIM, LIST, ETC) ? YES
DOES THE TANK STRAPPING TABLES HAVE 100% CAPACITIES FOR INDIVIDUAL TANKS ? YES
DOES THE TANK STRAPPING TABLES HAVE GAUGE HEIGHTS FOR INDIVIDUAL TANKS ? YES
DOES THE TANK STRAPPING TABLES HAVE TEMPERATURE PROFILES FOR INDIVIDUAL TANKS ? YES
3. SHORE OPERATIONS - DURING LOAD
WAS CORRECT NUMBER OF SAMPLES PULLED AT THE PROPER TIME DURING LOAD ? YES
4. VESSEL OPERATIONS - ON DEPARTURE
ARE ALL PRIMARY CUSTODY GAUGING DEVISES OPERATIONAL ON DEPARTURE ? YES
ARE ALL SECONDARY CUSTODY GAUGING DEVISES OPERATIONAL ON DEPARTURE ? YES
ARE ALL CUSTODY REMOTE TEMPERATURE DEVISES OPERATIONAL ON DEPARTURE ? YES
ARE ALL CUSTODY PRESSURE DEVISES OPERATIONAL ON DEPARTURE ? YES
WERE THE TANKS "BOTTLED UP" DURING CLOSING CUSTODY TRANSFER MEASUREMENT ? YES
5. SHORE OPERATIONS - AFTER LOAD
WAS THE GC VERIFIED AGAINST A CERTIFIED REFERENCE AFTER LOADING / USAGE ? YES
DID THE TERMINAL SUPPLY A CERTIFICATE OF VERIFICATION FOR THE GC ? YES
DID THE TERMINAL SUPPLY A COMPOSITIONAL PRINT OUT OF THE GC DURING LOAD ? YES
6. ADDITIONAL INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
Checklist 1 - Discontinuous Sampling System LNG-LD-009H1 (07-AUG-09) - 14
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
O P E R A T I O N A L C H E C K L I S T
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. SHORE OPERATIONS - PRIOR TO LOAD
WAS THE GAS SAMPLING EQUIPMENT (LINES, TANK, ETC.) INSPECTED AND PURGED ? YES
WAS THE GAS SAMPLING EQUIPMENT SET UP PROPERLY TO RECEIVE SAMPLE ? YES
2. VESSEL OPERATIONS - ON ARRIVAL
WERE ALL PRIMARY CUSTODY GAUGING DEVISES OPERATIONAL ON ARRIVAL ? YES
DID THE PRIMARY SYSTEM HAVE A CURRENT CERTIFICATE OF CALIBRATION ? YES
WERE ALL SECONDARY CUSTODY GAUGING DEVISES OPERATIONAL ON ARRIVAL ? YES
DID THE SECONDARY SYSTEM HAVE A CURRENT CERTIFICATE OF CALIBRATION ? YES
WERE ALL CUSTODY REMOTE TEMPERATURE DEVISES OPERATIONAL ON ARRIVAL ? YES
DID THE TEMPERATURE SYSTEM HAVE A CURRENT CERTIFICATE OF CALIBRATION ? YES
WERE ALL CUSTODY PRESSURE DEVISES OPERATIONAL ON ARRIVAL ? YES
DID THE PRESSURE SYSTEM HAVE A CURRENT CERTIFICATE OF CALIBRATION ? YES
WERE THE TANKS "BOTTLED UP" DURING OPENING CUSTODY TRANSFER MEASUREMENT ? YES
DID THE VESSEL HAVE CURRENT CERTIFIED TANK STRAPPING TABLES ? YES
WERE THE TANK STRAPPING TABLES WRITTEN IN ENGLISH ? YES
DID THE TANK STRAPPING TABLES EXPLAIN HOW TO UTILIZED THE TABLES ? YES
DID THE TANK STRAPPING TABLES HAVE GAUGE CORRECTION FACTORS (TRIM, LIST, ETC) ? YES
DID THE TANK STRAPPING TABLES HAVE 100% CAPACITIES FOR INDIVIDUAL TANKS ? YES
DID THE TANK STRAPPING TABLES HAVE GAUGE HEIGHTS FOR INDIVIDUAL TANKS ? YES
DID THE TANK STRAPPING TABLES HAVE TEMPERATURE PROFILES FOR INDIVIDUAL TANKS ? YES
3. SHORE OPERATIONS - DURING LOAD
WERE THE CORRECT NUMBER OF SPOT SAMPLES PULLED AT THE PROPER TIME DURING LOAD ? YES
4. VESSEL OPERATIONS - ON DEPARTURE
WERE ALL PRIMARY CUSTODY GAUGING DEVISES OPERATIONAL ON DEPARTURE ? YES
WERE ALL SECONDARY CUSTODY GAUGING DEVISES OPERATIONAL ON DEPARTURE ? YES
WERE ALL CUSTODY REMOTE TEMPERATURE DEVISES OPERATIONAL ON DEPARTURE ? YES
WERE ALL CUSTODY PRESSURE DEVISES OPERATIONAL ON DEPARTURE ? YES
WERE THE TANKS "BOTTLED UP" DURING CLOSING CUSTODY TRANSFER MEASUREMENT ? YES
5. SHORE OPERATIONS - AFTER LOAD
DID THE GAS SAMPLING EQUIPMENT WORK PROPERLY THROUGHOUT THE ENTIRE LOAD ? YES
WERE THE CORRECT NUMBER OF TESTING SAMPLES COLLECTED FROM THE GAS SAMPLE HOLDER ? YES
DID THE TERMINAL SUPPLY A CURRENT REPORT OF CALIBRATION FOR THE GC ? YES
WAS THE GC VERIFIED AGAINST A CERTIFIED REFERENCE GAS PRIOR TO TESTING ? YES
WAS THE GC VERIFIED AGAINST A CERTIFIED REFERENCE GAS AFTER TESTING ? YES
DID THE CERTIFIED REFERENCE GAS HAVE A CURRENT CERTIFICATE OF ANALYSIS ? YES
DID THE TERMINAL SUPPLY A CERTIFICATE OF VERIFICATION FOR THE GC AFTER TESTING ? YES
DID THE TERMINAL SUPPLY A COMPOSITIONAL PRINT OUT OF THE GC ANALYSIS ? YES
6. ADDITIONAL INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
Checklist 2 - Continuous Sampling System LNG-LD-009H1 (07-AUG-09) - 14
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
V E R I F I C A T I O N O F G C
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. OPENING VERIFICATION OF GC
COMPONENTCERTIFIED VARIANCE TEST GC VARIANCE TEST GC VARIANCE TEST GC VARIANCE
RESULTS ALLOWED RUN #1 PCT. RUN #2 PCT. RUN #3 PCT.
METHANE 91.9398 1.00% 91.9301 0.01% 91.9397 0.00% 91.9355 0.00%
ETHANE 5.0400 10.00% 5.0499 -0.20% 5.0412 -0.02% 5.0422 -0.04%
PROPANE 1.0020 10.00% 1.0028 -0.08% 1.0034 -0.14% 1.0020 0.00%
ISO BUTANE 0.1520 10.00% 0.1526 -0.39% 0.1523 -0.20% 0.1530 -0.66%
N-BUTANE 0.2030 10.00% 0.2031 -0.05% 0.2027 0.15% 0.2030 0.00%
ISO PENTANE 0.0531 10.00% 0.0532 -0.19% 0.0528 0.56% 0.0535 -0.75%
N-PENTANE 0.0538 10.00% 0.0543 -0.93% 0.0534 0.74% 0.0540 -0.37%
HEXANE + HVR 0.0503 10.00% 0.0501 0.40% 0.0500 0.60% 0.0508 -0.99%
NITROGEN 1.0130 10.00% 1.0130 0.00% 1.0139 -0.09% 1.0150 -0.20%
CARBON DIOXIDE 0.4930 10.00% 0.4909 0.43% 0.4906 0.49% 0.4910 0.41%
OXYGEN 0.0000 10.00% 0.0000 0.00% 0.0000 0.00% 0.0000 0.00%
TOTAL 100.0000 100.0000 100.0000 100.0000
OPENING VERIFICATION FOUND WITHIN VARIANCE YES DATE : 26-May-2007 TIME : 08:00
2. CLOSING VERIFICATION OF GC
COMPONENTCERTIFIED VARIANCE TEST GC VARIANCE TEST GC VARIANCE TEST GC VARIANCE
RESULTS ALLOWED RUN #1 PCT. RUN #2 PCT. RUN #3 PCT.
METHANE 91.9398 1.00% 91.9301 0.01% 91.9397 0.00% 91.9355 0.00%
ETHANE 5.0400 10.00% 5.0499 -0.20% 5.0412 -0.02% 5.0422 -0.04%
PROPANE 1.0020 10.00% 1.0028 -0.08% 1.0034 -0.14% 1.0020 0.00%
ISO BUTANE 0.1520 10.00% 0.1526 -0.39% 0.1523 -0.20% 0.1530 -0.66%
N-BUTANE 0.2030 10.00% 0.2031 -0.05% 0.2027 0.15% 0.2030 0.00%
ISO PENTANE 0.0531 10.00% 0.0532 -0.19% 0.0528 0.56% 0.0535 -0.75%
N-PENTANE 0.0538 10.00% 0.0543 -0.93% 0.0534 0.74% 0.0540 -0.37%
HEXANE + HVR 0.0503 10.00% 0.0501 0.40% 0.0500 0.60% 0.0508 -0.99%
NITROGEN 1.0130 10.00% 1.0130 0.00% 1.0139 -0.09% 1.0150 -0.20%
CARBON DIOXIDE 0.4930 10.00% 0.4909 0.43% 0.4906 0.49% 0.4910 0.41%
OXYGEN 0.0000 10.00% 0.0000 0.00% 0.0000 0.00% 0.0000 0.00%
TOTAL 100.0000 100.0000 100.0000 100.0000
CLOSING VERIFICATION FOUND WITHIN VARIANCE YES DATE : 26-May-2007 TIME : 10:00
3. EQUIPMENT INFORMATION AND CERTIFIED REFERENCE GAS
TESTING EQUIPMENT MAKE : AC.AGILENT MODEL : 6890
LAST CALIBRATION DATE : 15-Feb-2007 TIME : 17:00
CERTIFIED REFERENCE GAS SUPPLIER : SCOTT GAS SERIAL # : 7800102
CERTIFICATION DATE : 15-Feb-2007 TIME : 17:00
4. ADDITIONAL INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
Verification of GC 1 - Site Specific LNG-LD-009H1 (07-AUG-09) - 14
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
V E R I F I C A T I O N O F G C
VESSEL : SK SPLENDOR DATE : 13-Nov-2007 TIME : 15:00
TERMINAL/PORT : OMAN LNG / SUR, OMAN
INSTRUMENT : GC C (HP 5890) LABORATORY TEMP : 23-23.5 °C
1. REFERENCE STANDARD GAS Cylinder # : GS 66889
COMPONENT Repeatability
(A) (B)
METHANE CH4 90.4013 272,701 272,177 0.19 272,439.0
ETHANE C2H6 4.4400 607,832 606,946 0.15 607,389.0
PROPANE C3H8 3.3500 701,594 702,057 0.07 701,825.5
ISO BUTANE i-C4H10 0.7080 198,953 198,637 0.16 198,795.0
N-BUTANE n-C4H10 0.6850 193,667 193,331 0.17 193,499.0
ISO PENTANE i-C5H12 0.0286 10,224 10,178 0.45 10,201.0
N-PENTANE n-C5H12 0.0286 9,937 9,918 0.19 9,927.5
NITROGEN N2 0.2870 32,521 32,198 1.00 32,359.5
OXYGEN O2 0.0297 3,283 3,195 2.72 3,239.0
CARBON DIOXIDE CO2 0.0418 5,636 5,791 2.71 5,713.5
TOTAL 100.0000
2. SAMPLE GAS Cylinder # : CPC-01 Seal # : 004659
COMPONENT Repeatability
(C) (C) x (A) / (B) (D) (D) x (A) / (B)
METHANE CH4 276,238 91.662 276,313 91.687 0.03
ETHANE C2H6 692,500 5.062 692,706 5.064 0.03
PROPANE C3H8 440,672 2.103 440,935 2.105 0.06
ISO BUTANE i-C4H10 89,076 0.317 89,110 0.317 0.04
N-BUTANE n-C4H10 72,378 0.256 72,288 0.256 0.12
ISO PENTANE i-C5H12 0 0.000 0 0.000 0.00
N-PENTANE n-C5H12 0 0.000 0 0.000 0.00
NITROGEN N2 2,494 0.022 2,488 0.022 0.24
OXYGEN O2 0 0.000 0 0.000 0.00
CARBON DIOXIDE CO2 0 0.000 0 0.000 0.00
TOTAL 99.422 99.451
3. NORMALIZATION
COMPONENT
(E) (E) x (A) / (B)
METHANE CH4 276,275.5 91.674 92.19 92.8085 -0.6185
ETHANE C2H6 692,603.0 5.063 5.09 4.7397 0.3503
PROPANE C3H8 440,803.5 2.104 2.12 1.8893 0.2307
ISO BUTANE i-C4H10 89,093.0 0.317 0.32 0.2689 0.0511
N-BUTANE n-C4H10 72,333.0 0.256 0.26 0.2151 0.0449
ISO PENTANE i-C5H12 0.0 0.000 0.00 0.0022 -0.0022
N-PENTANE n-C5H12 0.0 0.000 0.00 0.0000
NITROGEN N2 2,491.0 0.022 0.02 0.0762 -0.0562
OXYGEN O2 0.0 0.000 0.00 0.0000
CARBON DIOXIDE CO2 0.0 0.000 0.00 0.0000
TOTAL 99.436 100.00 100.000
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
Verification of GC 2 - Site Specific LNG-LD-009H1 (07-AUG-09) - 14
Concent Mol % First RSG
Count Peak AreaSecond RSG Count Peak Area
Average RSG Count Peak
Area
First Sample Count Peak
AreaUnnormal
Mol %
Second Sample Count
Peak AreaUnnormal
Mol %
Average Sample Count Peak Area
Unnormal Mol % Reported
Value Mol%Load Port
Mol %
Difference
%
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
B U N K E R S U R V E Y
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. VESSEL HISTORY FROM CHIEF ENGINEER
BUNKER PRODUCT : FUEL OIL DAYS AT SEA : 9.00 AT ANCH : 0.00
LAST PORT OF CALL : SINGAPORE AVERAGE BUNKER CONSUMPTION PER DAY
BUNKERS ON DEPARTURE : 1337.000 METRIC TONS AT SEA : 200.000 METRIC TONS
BUNKERS AT E.O.S.P. : 1463.160 METRIC TONS AT LOAD : 20.000 METRIC TONS
BUNKERS RECEIVED INTRANSIT : 3713.910 METRIC TONS AT DISC : 20.000 METRIC TONS
BUNKERS RECEIVED IN PORT : 0.000 METRIC TONS AT ANCHOR : 20.000 METRIC TONS
2. INSPECTION UPON ARRIVAL
VESSEL'S ULLAGES G.O.V. TEMP. V.C.F. G.S.V. DENSITY M. TONS
TANK METERS m3 °C T54B - 2004 m3 @ 15°C ( AIR )
TANK 1 FWD 24.200 0.000 20.0 0.99658 0.000 0.9894 0.000
TANK 2 STB 4.970 481.000 42.8 0.98092 471.823 0.9894 466.302
TANK 2 PORT 8.401 474.000 49.0 0.97664 462.927 0.9894 457.511
TANK 4 STB 3.633 141.000 39.7 0.98306 138.611 0.9894 136.990
TANK 1 SETTLING 8.790 212.000 60.0 0.96902 205.432 0.9894 203.029
TANK 2 SETTLING 5.476 197.000 60.0 0.96902 190.897 0.9894 188.663
TOTALS 1505.000 G.S.V. = 1469.691 M.T. = 1452.495
DATE : 3-Jun-2008 TIME : 07:40 DRAFT FWD : 9.60 m DRAFT AFT : 9.78 m
3. INSPECTION PRIOR TO SAILING
VESSEL'S ULLAGES G.O.V. TEMP. V.C.F. G.S.V. DENSITY M. TONS
TANK METERS m3 °C T54B - 2004 m3 @ 15°C ( AIR )
TANK 1 FWD 0.000 0.000 20.0 0.99658 0.000 0.9894 0.000
TANK 2 STB 4.950 482.000 43.0 0.98078 472.736 0.9894 467.205
TANK 2 PORT 8.420 474.000 44.0 0.98009 464.563 0.9894 459.127
TANK 4 STB 3.630 140.000 39.0 0.98354 137.696 0.9894 136.085
TANK 1 SETTLING 8.790 213.000 55.0 0.97249 207.140 0.9894 204.717
TANK 2 SETTLING 5.130 123.000 55.0 0.97249 119.616 0.9894 118.217
TOTALS 1432.000 G.S.V. = 1401.751 M.T. = 1385.351
DATE : 5-Jun-2008 TIME : 15:00 DRAFT FWD : 11.45 m DRAFT AFT : 11.50 m
4. ADDITIONAL INFORMATION AND COMMENTS
QUANTITY OF BUNKERS CONSUMED DURING VOYAGE : 3598.415 METRIC TONS
QUANTITY OF BUNKERS CONSUMED DURING LOAD : 67.144 METRIC TONS
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
Bunker - Fuel Oil LNG-LD-009H1 (07-AUG-09) - 14
G.O.V. =
G.O.V. =
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
B U N K E R S U R V E Y
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. VESSEL HISTORY FROM CHIEF ENGINEER
BUNKER PRODUCT : MARINE DIESEL OIL DAYS AT SEA : 9.00 AT ANCH : 0.00
LAST PORT OF CALL : SINGAPORE AVERAGE BUNKER CONSUMPTION PER DAY
BUNKERS ON DEPARTURE : 159.890 METRIC TONS AT SEA : 0.000 METRIC TONS
BUNKERS AT E.O.S.P. : 133.800 METRIC TONS AT LOAD : 0.000 METRIC TONS
BUNKERS RECEIVED INTRANSIT : 0.000 METRIC TONS AT DISC : 1.000 METRIC TONS
BUNKERS RECEIVED IN PORT : 0.000 METRIC TONS AT ANCHOR : 0.000 METRIC TONS
2. INSPECTION UPON ARRIVAL
VESSEL'S ULLAGES G.O.V. TEMP. V.C.F. G.S.V. DENSITY M. TONS
TANK METERS m3 °C T54B - 2004 m3 @ 15°C ( AIR )
D.O TK 6.062 80.200 25.0 0.99180 79.542 0.8600 68.319
D.O SERVICE 3.908 77.300 25.0 0.99180 76.666 0.8600 65.849
TOTALS 157.500 G.S.V. = 156.209 M.T. = 134.168
DATE : 3-Jun-2008 TIME : 07:40 DRAFT FWD : 9.60 m DRAFT AFT : 9.78 m
3. INSPECTION PRIOR TO SAILING
VESSEL'S ULLAGES G.O.V. TEMP. V.C.F. G.S.V. DENSITY M. TONS
TANK METERS m3 °C T54B - 2004 m3 @ 15°C ( AIR )
D.O TK 6.063 80.200 25.0 0.99180 79.542 0.8600 68.319
D.O SERVICE 3.908 77.300 25.0 0.99180 76.666 0.8600 65.849
TOTALS 157.500 G.S.V. = 156.209 M.T. = 134.168
DATE : 5-Jun-2008 TIME : 15:00 DRAFT FWD : 11.45 m DRAFT AFT : 11.50 m
4. ADDITIONAL INFORMATION AND COMMENTS
QUANTITY OF BUNKERS CONSUMED DURING VOYAGE : 25.722 METRIC TONS
QUANTITY OF BUNKERS CONSUMED DURING LOAD : 0.000 METRIC TONS
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
Bunker - Diesel Oil LNG-LD-009H1 (07-AUG-09) - 14
G.O.V. =
G.O.V. =
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
T I M E L O G
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. TIMES
DATE HOUR EVENT
4-Aug-2009 05:15 END OF SEA PASSAGE
4-Aug-2009 09:15 NOTICE OF READINESS TENDERED
4-Aug-2009 06:54 PILOT ON BOARD
4-Aug-2009 08:15 FIRST LINE ASHORE
4-Aug-2009 09:15 VESSEL ALL FAST
4-Aug-2009 09:22 TERMINAL GANGWAY DOWN & SECURE
4-Aug-2009 09:22 INSPECTOR ON BOARD
4-Aug-2009 09:32 COMMENCED CONNECTION OF CARGO & VAPOR ARMS
4-Aug-2009 09:49 COMPLETED CONNECTION OF CARGO & VAPOR ARMS
4-Aug-2009 10:00 COMMENCED PRE-LOAD KEY / SAFETY MEETING
4-Aug-2009 10:30 COMPLETED PRE-LOAD KEY / SAFETY MEETING
4-Aug-2009 10:33 COMMENCED TESTING OF E.S.D.
4-Aug-2009 09:15 NOTICE OF READINESS ACCEPTED
4-Aug-2009 10:27 COMMENCED OPENING CUSTODY TRANSFER INSPECTION
4-Aug-2009 10:28 COMPLETED OPENING CUSTODY TRANSFER INSPECTION
4-Aug-2009 10:40 COMMENCED COOL DOWN OF CARGO ARMS & VESSEL LINES
4-Aug-2009 12:15 COMPLETED COOL DOWN OF CARGO ARMS & VESSEL LINES
4-Aug-2009 12:20 COMMENCED LOADING OF CARGO
4-Aug-2009 12:59 FULL RATE LOADING
5-Aug-2009 02:47 LOADING RATE DOWN START
5-Aug-2009 03:25 COMPLETED LOADING
5-Aug-2009 04:21 COMMENCED CLOSING CUSTODY TRANSFER INSPECTION
5-Aug-2009 04:22 COMPLETED CLOSING CUSTODY TRANSFER INSPECTION
5-Aug-2009 04:25 COMMENCED DISCONNECTION OF VARGO & VAPOR ARMS
5-Aug-2009 04:39 COMPLETED DISCONNECTION OF CARGO & VAPOR ARMS
5-Aug-2009 05:00 POST LOADING MEETING & DOCUMENTATION
5-Aug-2009 05:15 VESSEL CLEAR
5-Aug-2009 06:30 ETS
5-Aug-2009 06:05 ANALYSIS COMPLETED
5-Aug-2009 06:25 COMMENCED CLOSING CUSTODY TRANSFER INSPECTION
5-Aug-2009 06:26 COMPLETED CLOSING CUSTODY TRANSFER INSPECTION
5-Aug-2009 06:52 COMMENCED DISCONNECTION OF CARGO & VAPOR ARMS
5-Aug-2009 07:17 COMPLETED DISCONNECTION OF CARGO & VAPOR ARMS
5-Aug-2009 07:30 POST LOADING MEETING & DOCUMENTATION
5-Aug-2009 07:40 VESSEL CLEARED
5-Aug-2009 08:00 VESSEL SAILED
5-Aug-2009 08:00 ANALYSIS COMPLETED
2. ADDITIONAL INFORMATION AND COMMENTS
Sampling started : 17:15 0n 31st July 2008 and completed at 06:20 0n 01st August 2008
Analysis completed : 09:15 on 1st August 2008
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
Time Log - Page 1 LNG-LD-009H1 (07-AUG-09) - 14
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
T I M E L O G
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. TIMES
DATE HOUR EVENT
2. ADDITIONAL INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
Time Log - Page 2 LNG-LD-009H1 (07-AUG-09) - 14
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
T I M E L O G
VESSEL : SK SPLENDOR DATE : 4-Aug-2009 TO 5-Aug-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. TIMES
DATE HOUR EVENT
2. ADDITIONAL INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT FOR TERMINAL FOR VESSEL
Time Log - Page 3 LNG-LD-009H1 (07-AUG-09) - 14
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
L E T T E R O F P R O T E S T
VESSEL : SK SPLENDOR DATE : TIME :
TERMINAL/PORT : OMAN LNG / SUR, OMAN
TO :
SIR :
RECEIVED BY YOURS FAITHFULLY,
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT
LOP 1 LNG-LD-009H1 (07-AUG-09) - 14
ON BEHALF OF OUR CLIENT(S), WE HAVE BEEN APPOINTED INSPECTORS ON THE ABOVE NAMED VESSEL. ACTING FOR AND ON THEIR BEHALF, WE HEREBY NOTIFY YOU THAT ON THE LISTED DATE AND TIME THE FOLLOWING OCCURRED.
WE HEREBY RESERVE THE RIGHT OF OUR PRINCIPALS TO REFER TO THIS MATTER AT A LATER DATE AND TAKE SUCH ACTION AS MAY BE DEEMED NECESSARY.
KINDLY ACKNOWLEDGE RECEIPT ON THE COPY THEREOF AND RETURN IT TO US. THE SIGNATURE THUS OBTAINED ARE FOR RECEIPT ONLY AND IN NO WAY ACKNOWLEDGE RESPONSIBILITY FOR THE INCIDENT.
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
L E T T E R O F P R O T E S T
VESSEL : SK SPLENDOR DATE : TIME :
TERMINAL/PORT : OMAN LNG / SUR, OMAN
TO :
SIR :
RECEIVED BY YOURS FAITHFULLY,
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT
LOP2 LNG-LD-009H1 (07-AUG-09) - 14
ON BEHALF OF OUR CLIENT(S), WE HAVE BEEN APPOINTED INSPECTORS ON THE ABOVE NAMED VESSEL. ACTING FOR AND ON THEIR BEHALF, WE HEREBY NOTIFY YOU THAT ON THE LISTED DATE AND TIME THE FOLLOWING OCCURRED.
WE HEREBY RESERVE THE RIGHT OF OUR PRINCIPALS TO REFER TO THIS MATTER AT A LATER DATE AND TAKE SUCH ACTION AS MAY BE DEEMED NECESSARY.
KINDLY ACKNOWLEDGE RECEIPT ON THE COPY THEREOF AND RETURN IT TO US. THE SIGNATURE THUS OBTAINED ARE FOR RECEIPT ONLY AND IN NO WAY ACKNOWLEDGE RESPONSIBILITY FOR THE INCIDENT.
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
L E T T E R O F P R O T E S T
VESSEL : SK SPLENDOR DATE : TIME :
TERMINAL/PORT : OMAN LNG / SUR, OMAN
TO :
SIR :
RECEIVED BY YOURS FAITHFULLY,
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT
LOP 3 LNG-LD-009H1 (07-AUG-09) - 14
ON BEHALF OF OUR CLIENT(S), WE HAVE BEEN APPOINTED INSPECTORS ON THE ABOVE NAMED VESSEL. ACTING FOR AND ON THEIR BEHALF, WE HEREBY NOTIFY YOU THAT ON THE LISTED DATE AND TIME THE FOLLOWING OCCURRED.
WE HEREBY RESERVE THE RIGHT OF OUR PRINCIPALS TO REFER TO THIS MATTER AT A LATER DATE AND TAKE SUCH ACTION AS MAY BE DEEMED NECESSARY.
KINDLY ACKNOWLEDGE RECEIPT ON THE COPY THEREOF AND RETURN IT TO US. THE SIGNATURE THUS OBTAINED ARE FOR RECEIPT ONLY AND IN NO WAY ACKNOWLEDGE RESPONSIBILITY FOR THE INCIDENT.
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
L E T T E R O F P R O T E S T
VESSEL : SK SPLENDOR DATE : TIME :
TERMINAL/PORT : OMAN LNG / SUR, OMAN
TO :
SIR :
RECEIVED BY YOURS FAITHFULLY,
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT
LOP 4 LNG-LD-009H1 (07-AUG-09) - 14
ON BEHALF OF OUR CLIENT(S), WE HAVE BEEN APPOINTED INSPECTORS ON THE ABOVE NAMED VESSEL. ACTING FOR AND ON THEIR BEHALF, WE HEREBY NOTIFY YOU THAT ON THE LISTED DATE AND TIME THE FOLLOWING OCCURRED.
WE HEREBY RESERVE THE RIGHT OF OUR PRINCIPALS TO REFER TO THIS MATTER AT A LATER DATE AND TAKE SUCH ACTION AS MAY BE DEEMED NECESSARY.
KINDLY ACKNOWLEDGE RECEIPT ON THE COPY THEREOF AND RETURN IT TO US. THE SIGNATURE THUS OBTAINED ARE FOR RECEIPT ONLY AND IN NO WAY ACKNOWLEDGE RESPONSIBILITY FOR THE INCIDENT.
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
N I G E R I A L N G C E R T I F I C A T E O F L O A D I N G
VESSEL : SK SPLENDOR DATE : 15-Apr-2008
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. IDENTIFICATION
(a) CARGO RECEIVER (NLNG CUSTOMER) : BRITISH GAS
(b) NIGERIA LNG CARGO NUMBER : 963
(c) COMMENCED LOADING OF LNG DATE : 11-May-2008 TIME : 23:00
(d) COMPLETED LOADING ON LNG DATE : 13-May-2008 TIME : 01:00
2. BASIC DATA
(a) LIQUID LNG VOLUME LOADED : 135,888.000 CUBIC METERS
(b) AVERAGE TEMPERATURE OF LIQUID AFTER LOADING : -160.2 °C
(c) AVERAGE TEMPERATURE OF VAPOR BEFORE LOADING : -128.5 °C
(d) AVERAGE ABSOLUTE PRESSURE BEFORE LOADING : 1166 mbar
(e) LNG CARGO COMPOSITION:
COMPONENTS MOLE PERCENTAGE
NITROGEN 0.28
METHANE 90.24
ETHANE 5.95
PROPANE 2.24
ISO BUTANE 0.69
N-BUTANE 0.58
ISO PENTANE 0.02
N-PENTANE & HEAVIER 0
(f) IMPURITIES
CARBON DIOXIDE : 0 mol %
MERCURY : N/A ng / Nm3
MERCAPTAN : N/A mg / Nm3
HYDROGEN SULFIDE : N/A mg / Nm3
CARBONYL SULFIDE : N/A mg / Nm3
TOTAL SULFUR : N/A mg / Nm3
(g) HYDROCARBON DEWPOINT (MAX - between 1-80 bar gauge) : N/A °C
3. RESULTS
(a) LNG DENSITY AT -160.2 °C : 459.080
(b) GROSS CALORIFIC VALUE (MASS) : 54.4361 MJ / kg
(c) GROSS CALORIFIC VALUE (VOLUME) : 1115 BTU / SCF
(d) WOBBE INDEX (VOLUME) : 1411 BTU / SCF
4. TOTAL QUANTITY OF LNG UNLOADED
MEGAJOULES MMBTU KILOWATT HOURS
GROSS QUANTITY DELIVERED 3,395,719,322 3,218,508 943,255,367
QUANTITY DISPLACED 11,743,022 11,130 3,261,951
QUANTITY CONSUMED BY VESSEL 0 0 0
QUANTITY FOR GAS-UP 0 0 0
QUANTITY FOR COOL DOWN 0 0 0
ADJUSTED QUANTITY DELIVERED 3,383,978,343 3,207,380 939,993,417
5. ADDITIONAL INFORMATION AND COMMENTS
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F.
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT
CSR 1 - Nigeria LNG Certificate of Loading LNG-LD-009H1 (07-AUG-09) - 14
N2
C1
C2
C3
i-C4
n-C4
i-C5
n-C5 +
kg / m3
BG DATA SHEET - LOAD
Vessel Name: SK SPLENDOR Terminal / Port: OMAN LNGCargo No: OF039/09-SL100-KG Last Port of Call: INCHEON
Dates: JAN 4-5, 2009 Dates at Last Port: 20-Jul-2009File #: SUR/09/134 Last Port CCT Volume: 1,553.335 m3
LNG DataTotal Load Volume 135,888.000 m3
Total Load Quantity 3,207,380 MMBtu (60°F)BG - Total Load Quantity 3,207,380 MMBtu (60°F)
Total Load Quantity 62,172.077 MTCooldown Volume 0.000 m3Cooldown Volume 0 MMBtu (60°F)
Gas up Volume 0.000 m3Gas up Volume 0 MMBtu (60°F)
Vessel OCT Volume before loading 404.978 m3Vessel CCT Volume after loading 136,292.944 m3
Vessel Volume Received 135,888.000 m3Observied Liquid Temp after loading -160.2 Deg. C
LNG Density @ -160.2 °C 459.080 KG/M3LNG Density @ -160.0 °C 458.800 KG/M3
Higher Heating Value (mass) 54.4361 MJ / kg (15°C)BG - Higher Heating Value (mass) 51593 BTU / kg (60°F)
Higher Heating Value (Volume) 1115 BTU / SCF (60/60°F & 14.696 psi)BG - Higher Heating Value (Volume) 1117.6 BTU / SCF (60/60°F & 14.73 psi)
Wobbe Index 1411 BTU / SCF (60/60°F & 14.696 psi)BG - Wobbe Index 1414.3 BTU / SCF (60/60°F & 14.73 psi)
Gross Energy Received 3,218,508 MMBtu (60°F)Vapor Return 11,130 MMBtu (60°F)
Energy Delivered 3,207,380 MMBtu (60°F)Gas Consumed During Load 0 MMBtu (60°F)
Net Energy Received 3,207,378 MMBtu (60°F)Intransit Difference 1148.357 m3
Last Port of call CCT inspection: 20-Jul-2009 Date 15:48 TimeLoad Port OCT inspection 4-Aug-2009 Date 10:28 Time
Time zone adjustment between ports Hrs E to WLength of Voyage Days
Estimated LNG Boil-off per day % per dayVessel Design Limits % per day
Bunker Data (Fuel Oil)Bunkers on Closing Last Port 1,337.000 MT
Bunker Survey Date TimeBunkers on Opening Load Port 1452.495 MT
Bunker Survey 3-Jun-2008 Date 07:40 TimeBunkers on Closing Load Port 1385.351 MT
Bunker Survey 5-Jun-2008 Date 15:00 TimeBunkers Received intransit 3713.910 MT
Average Daily Consumption Rates:At Load 20.000 MT
At Discharge 20.000 MTAt Sea 200.000 MT
At Anchorage: 20.000 MTQuality
Methane CH4 90.2400 % mol
Ethane C2H6 5.9500 % mol
Propane C3H8 2.2400 % mol
i-Butane i-C4H10 0.6900 % mol
n-Butane n-C4H10 0.5800 % mol
i-Pentane i-C5H12 0.0200 % mol
n-Pentane n-C5H12 0.0000 % mol
n-Hexane n-C6H14 0.0000 % mol
Nitrogen N2 0.2800 % mol
Carbon Dioxide CO2 0.0000 % molImpurities
Mercury ng/Nm3Mercaptans mg/Nm3Mercaptans ppm
Hydrogen Sulphide mg/Nm3Hydrogen Sulphide ppm
Total Sulphur mg/Nm3Total Sulphur ppm
Time log Summary AdditionsOCT Inspection Completed 4-Aug-2009 Date 10:28 Time
CCT Inspection Completed 5-Aug-2009 Date 04:17 Time
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
B P C E R T I F I C A T E O F L O A D I N G
VESSEL : SK SPLENDOR DATE : 15-Apr-2008
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. QUALITY
COMPONENTS IMPURITIES
METHANE 90.24 Mol % NITROGEN 0.28 Mol %
ETHANE 5.95 Mol % CARBON DIOXIDE 0 Mol %
PROPANE 2.24 Mol % OXYGEN 0 Mol %
ISO BUTANE 0.69 Mol % MERCURY N/A ng / Nm3
N-BUTANE 0.58 Mol % MERCAPTAN N/A mg / Nm3
ISO PENTANE 0.02 Mol % HYDROGEN SULFIDE N/A mg / Nm3
N-PENTANE 0 Mol % CARBONYL SULFIDE N/A mg / Nm3
N-HEXANE 0 Mol % TOTAL SULFUR N/A mg / Nm3
AVERAGE TEMPERATURE OF LIQUID AFTER LOADING -160.2 °C
AVERAGE TEMPERATURE OF VAPOR BEFORE LOADING -128.5 °C
AVERAGE ABSOLUTE PRESSURE BEFORE LOADING 1166 mbar
LNG DENSITY AT -160.2 °C 459.080
GROSS CALORIFIC VALUE (MASS) 54.4361 MJ / kg
GROSS CALORIFIC VALUE (VOLUME) 1115 BTU / SCF
WOBBE INDEX (VOLUME) 1411 BTU / SCF
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F.
2. QUANTITY
VESSEL VOLUME ON ARRIVAL ( OPENING CUSTODY TRANSFER ) 404.978 CUBIC METERS
VESSEL VOLUME ON DEPARTURE ( CLOSING CUSTODY TRANSFER ) 136,292.944 CUBIC METERS
VESSEL VOLUME DELIVERED ( ROUNDED AS PER THE S.P.A. ) 135,888.000 CUBIC METERS
ADJUSTED MASS DELIVERED 62,172.077 METRIC TONS
MEGAJOULES MMBTU KILOWATT HOURS
GROSS QUANTITY DELIVERED 3,395,719,322 3,218,508 943,255,367
QUANTITY DISPLACED 11,743,022 11,130 3,261,951
QUANTITY CONSUMED BY VESSEL 0 0 0
QUANTITY FOR GAS-UP 0 0 0
QUANTITY FOR COOL DOWN 0 0 0
ADJUSTED QUANTITY DELIVERED 3,383,978,343 3,207,380 939,993,417
3. STATEMENT OF FACTS
DATE HOUR EVENT
13-Apr-2008 11:30 END OF SEA PASSAGE
13-Apr-2008 11:30 NOTICE OF READINESS TENDERED
14-Apr-2008 02:36 PILOT ON BOARD
14-Apr-2008 06:42 VESSEL ALL FAST
14-Apr-2008 06:42 NOTICE OF READINESS ACCEPTED
14-Apr-2008 08:12 CARGO ARMS CONNECTED
14-Apr-2008 09:00 COMMENCED CARGO OPERATIONS
15-Apr-2008 00:18 COMPLETED CARGO OPERATIONS
15-Apr-2008 00:48 CARGO ARMS DISCONNECTED
15-Apr-2008 02:54 VESSEL DEPARTURE
4. ADDITIONAL INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI
FOR INTERTEK CALEB BRETT
CSR 3 - BP Certificate of Loading LNG-LD-009H1 (07-AUG-09) - 14
kg / m3
LOADING REPORT CAPTIONINPUT CELLS
TELEX TREATMENT DATE : 5/5/2009 DD/MM/YYYY FORMS AAAAAATO BE ADJUSTED (drop-down list)
TANKER NAME : SK SPLENDOR CAPITAL (depending on operation, reference temperature...)
PORT : SUR, OMAN (NO COUNTRY ex : Idku)
CARGO REFERENCE NUMBER : OF039/09-SL100-KG CAPITAL
1.QUALITY:---------- VOLUMETRIC/METERING REFERENCE TEMPERATURE (for calculations) : 60
COMBUSTION REFERENCE TEMPERATURE (for calculations) : 60LNG CARGO COMPOSITION REFERENCE PRESSURE : 14.696 PSIAMESURED ON OPERATION
COMPONENTS UNIT
METHANE : 90.24 %ETHANE : 5.95 %
PROPANE : 2.24 %ISOBUTANE : 0.69 %
NORMAL BUTANE : 0.58 %ISOPENTANE : 0.02 %
NORMAL PENTANE : 0 %NORMAL HEXANE : 0 %
NITROGEN : 0.28 %CARBON DIOXIDE : 0 %
MERCURY : ng / Nm3HYDROGEN SULFIDE : mg / Nm3
MERCAPTAN : mg / Nm3TOTAL SULFUR : mg / Nm3
LNG DENSITY (@ observed Temp) : 459.080 KG/M3 (GNL)AVERAGE TEMPERATURE OF LNG DELIVERED : -160.2 °C
LNG GROSS CALORIFIC VALUE (MASS) : 54.4361 MJ / kg (@15°C)VAPOUR AVERAGE PRESSURE : 1166 mbar
VAPOUR GROSS CALORIFIC VALUE (VOLUME) : 1115 BTU / SCF (@60/60°F)VAPOUR AVERAGE TEMPERATURE : -128.5 °C
WOBBE INDEX : 1411 BTU / SCF (@60/60°F)
2.QUANTITY :----------INSPECTOR FIGURES ( WITHOUT COOLING DOWN AND GASSING UP IF ANY)
UNIT COOLING DOWN + GASSING UP QUANTITY IF APPLICABLEVOLUME BEFORE OPERATION : 404.978 M3 (GNL) UNIT
VOLUME AFTER OPERATION : 136,292.944 M3 (GNL) VOLUME : 0.000 M3 (GNL)TOTAL VOLUME DELIVERED : 135,888.000 M3 (GNL) ENERGY USED : 0 MMBTU (@60°F)
GROSS MASS DELIVERED : 62,172,077 KG (COOLING DOWN + GASSING UP)NET MASS DELIVERED (less gas return & ship consumption) : 62,172,077 KG
TOTAL ENERGY DELIVERED (less gas return & ship consumption) : 3,207,380 MMBTU (@60°F)
ENERGY OF GAS RETURN : 11,130 MMBTU (@60°F)
3.STATEMENT OF FACTS :------------------
END OF SEA PASSAGE : 5/5/2009 2:30 DD/MM/YY HH:MMARRIVAL AT ANCHOR AREA : 5/5/2009 2:30 DD/MM/YY HH:MM
PILOT ON BOARD : 5/5/2009 2:30 DD/MM/YY HH:MMBERTHING COMPLETED : 5/5/2009 2:30 DD/MM/YY HH:MM
NOTICE OF READINESS TENDERED : 5/5/2009 2:30 DD/MM/YY HH:MMNOTICE OF READINESS RECEIVED : 5/5/2009 2:30 DD/MM/YY HH:MM
OPEN CUSTODY TRANSFER COMPLETED : 5/5/2009 2:30 DD/MM/YY HH:MMOPERATION COMMENCED (1rst pump) : 5/5/2009 2:30 DD/MM/YY HH:MM
OPERATION COMPLETED : 5/5/2009 2:30 DD/MM/YY HH:MMCLOSING CUSTODY TRANSFER COMPLETED : 5/5/2009 2:30 DD/MM/YY HH:MM
DOCUMENTS ON BOARD : 5/5/2009 2:30 DD/MM/YY HH:MMVESSEL DEPARTURE : 5/5/2009 2:30 DD/MM/YY HH:MM
ETA NEXT PORT : 5/5/2009 2:30 DD/MM/YY HH:MMNEXT PORT CALL : BONNY ISLAND, NIGERIA (NO COUNTRY ex : MONTOIR)
4.OBSERVATIONS :-----------Delay before berthing / Delay before loading / Stops during loading / etc...
OUR REF : SUR/09/134
YOUR REF : OF039/09-SL100-KG
S A I L I N G S U M M A R Y R E P O R T
VESSEL : SK SPLENDOR DATE : 12-May-2009
TERMINAL/PORT : OMAN LNG / SUR, OMAN
1. TIME LOG
DATE HOUR EVENT
11-May-2009 06:30 VESSEL END OF SEA PASSAGE
11-May-2009 07:00 PILOT ON BOARD
11-May-2009 08:15 FIRST LINE ASHORE
11-May-2009 08:45 NOTICE OF READINESS TENDERED
11-May-2009 08:45 VESSEL ALL FAST
11-May-2009 09:00 COMMENCED PRE-LOAD KEY / SAFETY MEETING BETWEEN VESSEL & TERMINAL
11-May-2009 09:05 COMMENCED CONNECTION OF CARGO & VAPOR ARMS
11-May-2009 09:10 NOTICE OF READINESS ACCEPTED
11-May-2009 09:35 COMPLETED CONNECTION OF CARGO & VAPOR ARMS
11-May-2009 10:40 COMPLETED PRE-LOAD KEY / SAFETY MEETING BETWEEN VESSEL & TERMINAL
11-May-2009 10:45 COMPLETED TESTING OF E.S.D. (WARM CONDITION)
11-May-2009 10:54 COMPLETED OPENING CUSTODY TRANSFER INSPECTION
11-May-2009 11:05 COMPLETED OPENING CUSTODY TRANSFER CALCULATIONS
11-May-2009 12:12 COMMENCED COOL DOWN OPERATIONS OF CARGO ARMS & SHIP'S TANKS
11-May-2009 20:13 COMPLETED COOL DOWN OPERATIONS OF CARGO ARMS & SHIP'S TANKS
11-May-2009 20:23 COMPLETED TESTING OF E.S.D. (COLD CONDITION)
11-May-2009 20:33 COMMENCED LOADING OF CARGO
11-May-2009 22:20 VESSEL REACHED FULL LOADING RATE
12-May-2009 09:20 VESSEL COMMENCED REDUCTION OF LOADING RATE
12-May-2009 09:46 COMPLETED LOADING OF CARGO
12-May-2009 10:53 COMPLETED CLOSING CUSTODY TRANSFER INSPECTION
12-May-2009 11:10 COMPLETED CLOSING CUSTODY TRANSFER CALCULATIONS
12-May-2009 11:54 COMPLETED DISCONNECTION OF CARGO & VAPOR ARMS
12-May-2009 13:15 DOCUMENTS ON BOARD
12-May-2009 13:45 DOCUMENTATION COMPLETED
2. QUALITY
COMPONENTS METHOD SPA SPECIFICATIONS RESULTS UNITS
METHANE GPA 2261 NOT LESS THAN 85 % 90.24 mol %
ETHANE GPA 2261 NOT MORE THAN 8 % 5.95 mol %
PROPANE GPA 2261 NOT MORE THAN 3 % 2.24 mol %
ISO BUTANE GPA 2261
NOT MORE THAN 2 %
0.69 mol %
N-BUTANE GPA 2261 0.58 mol %
ISO PENTANE GPA 2261 0.02 mol %
N-PENTANE & HEAVIER GPA 2261 0.00 mol %
NITROGEN GPA 2261 NOT MORE THAN 1 % 0.28 mol %
CARBON DIOXIDE GPA 2261 0.00 mol %
HYDROGEN SULFIDE NOT MORE THAN 5 mg / Nm3 N/A mg / Nm3
TOTAL SULFUR NOT MORE THAN 30 mg / Nm3 N/A mg / Nm3
3. QUANTITY
LIQUID LNG VOLUME ON BOARD BEFORE LOADING : 404.978 CUBIC METERS
LIQUID LNG VOLUME ON BOARD AFTER LOADING : 136,292.944 CUBIC METERS
LIQUID LNG VOLUME LOADED : 135,888.000 CUBIC METERS
LNG DENSITY AT -160.2 °C : 459.080
GROSS CALORIFIC VALUE (VOLUME) : 1115 BTU / SCF
AVERAGE TEMPERATURE OF LIQUID AFTER LOADING : -160.2 °C
MASS DELIVERED (Liquid Delivered - Vapor Return + Consumed as Fuel) : 62,172.077 METRIC TONS
QUANTITY DELIVERED (Liquid Delivered - Vapor Return + Consumed as Fuel) : 3,207,380 MMBTU
GAS-UP QUANTITY : 0 MMBTU
COOL DOWN QUANTITY : 0 MMBTU
BEST REGARDS
kg / m3
PONNAPPA CHOKIRACSR 5 - Chubu Sailing Summary Report LNG-LD-009H1 (07-AUG-09) - 14