live imaging and other capabilities of the bioscience imaging facility (bif)
DESCRIPTION
Live Imaging and Other Capabilities of the Bioscience Imaging Facility (BIF). The Bioscience Imaging Facility. The BIF provides the instruments and expertise needed to visualize molecules in preparations ranging from single cells to entire animals. - PowerPoint PPT PresentationTRANSCRIPT
Live Imaging and Other Capabilitiesof the Bioscience Imaging Facility (BIF)
The BIF provides the instruments and expertise needed to visualize molecules in preparations ranging from single cells to entire animals.
• Project specific instrument training & advice
• Consultation on sample preparation, image processing, and data analysis
• Charge-back rates; Collaborations are encouraged
The Bioscience Imaging Facility
• High NA oil objectives 10x, 20x, 40x, 60x• Seven visible laser lines 446, 458, 488, 514, 561, 640 nm• Four channels or 32-bin spectral detection• Resonant scanner*• Piezo stage*• Live imaging chamber*
*Ideal for live imaging monolayer cell cultures
Rotate and Adj
• High NA oil objectives 10x, 20x, 40x, 60x• Seven visible laser lines 446, 458, 488, 514, 561, 640 nm• Four channel detection
• High NA oil objectives 10x, 20x, 40x, 60x
• Seven visible laser lines 446, 458, 488, 514, 561, 640 nm
• Four channels or 32-bin spectral detection• Resonant scanner & Piezo stage*• Live imaging chamber*
*Ideal for live imaging monolayer cell cultures
• High NA oil objectives 10x, 20x, 40x, 60x
• Seven visible laser lines 405, 458, 488, 514, 561, 640 nm
• Four channel detection
Nikon A1R
Nikon C1+
Confocal Microscopy
Resonant Galvanometer Piezoelectric z-stage
High Speed Image Acquisition
Spectral Acquisition
--Document spectra--Remove autofluorescence--Spectral FRET--Create virtual channels
T(λ) = C1•R1(λ) + C2•R2(λ)
Other Uses:
Spectral Unmixing
Fluorophoresin sample
Spectral Detector
• LWD (500 um) water 40x objective*• Mai Tai DeepSee tunable IR laser*• Four channel non-descanned detection*• Resonant scanner*• Live imaging chamber*• Confocal option Two laser lines (405, 488); four channel detection.
*Ideal for live imaging deep into living tissues
Nikon A1R_MP
Multiphoton Microscopy
• Phase and PlanFluor objectives* • DS-Ri1 color camera (standard)• Photometrics QuantEM CCD (optional)*• Live imaging chamber*
*Ideal for high sensitivity or high frame rate imaging of monolayer cell cultures
Nikon Ti-S
Wide-field Microscopy
Microscopic ImagesJuan Martinez, Mark HallBiochemistry
Pablo ZavattieriCivil Engineering
Shawn Liu, Xiaoqi LinBiology
Aaron TaylorBindley
• Cooled CCD• Range of excitation and emission filters Spans the 450-770 nm
• Isofluorane anesthesia provided
*Ideal for collecting signal from within an organism
IVIS Lumina II
In vivo Optical Imaging
In vivo Optical Images
Cansu Cimen, Tim RatliffComparative Pathobiology
Dan SzymanskiAgronomy
• Combined SPECT and x-ray CT Enables SPECT and CT image registration
• Multi-pinhole collimators High resolution imaging (350 um voxels) High sensitivity imaging (kBeq source)
• Data binning relative to biological rhythms Reduces blur
• List mode acquisition and statistical 3-D image reconstruction algorithm. Improves image quality
MiLabs U-SPECT-II/CT
Micro SPECT / CT Imaging
Principles of microSPECT
Principles of Statistical Reconstruction
?
Object Space
Projection Space
Micro SPECT / CT Images
Xin Lu, Shuang LiuHealth Sciences
Charity Wayua, Phil LowChemistry
Live Imaging Accessories
For more information:Email: [email protected]: http://www.purdue.edu/discoverypark/bioscience/facilities/imaging/index.php
Thank You!