Lead Paint Inspection Client: Private company, Kenne Square PA Descripon: Brownfield Science & Technology, Inc. (BSTI) provided technical lead assessment services to the owner of a structure undergoing renovaon. The structure was built in the late 18 th century and required substanal renovaon prior to occupaon. Due to the age of the structure, lead-based paint (LBP) was presumed to be present. A lead paint inspecon is a surface-by-surface invesgaon to determine whether there is lead-based paint in a structure or child-occupied facility. Inspecons can be legally performed only by cerfied inspectors or risk assessors. BSTIs objecves where to help our client to understand the level of screening appropriate and to provide documentaon to guide the on-scene construcon workers. Aſter some careful consideraon, BSTIs client opted for a modified lead-based paint inspecon that incorporated a combinaon of field screening and sample collecon. During the inspecon, components in each room as well as some exterior components were surveyed for the presence of LBP using a portable X-ray fluorescence (XRF) spectrum analyzer. A total of 136 XRF paint readings were taken and catalogued using in-system data capture. Aſter tesng with the XRF was completed, the inspector collected dust wipesamples to determine the quanty of lead in the dust throughout the structure. The results of the XRF tesng confirmed that lead-based paint was present on both interior and exterior surfaces. The dust wipe samples also showed that lead dust levels where present above EPA/HUD guidelines. As a result of the modified approach, the client was able to priorize and scale migaon acvies to assure protecveness of human health while maintaining their budget. BSTI was able to define the remaining, less significant risk factors within a context that was understood and therefore manageable to our client. Our client subsequently moved forward with their intended plans for the property. Objecve: Provide aconable data mid-construcon to inform and priorize lead-based paint migaon measures. Services: Environmental Consulng Lead Paint Inspecon Industrial Hygiene Lead Dust Sampling Applied Science/ Equipment and Materials: XRF Analyzer Lead Wipes Data interpretaon

Upload: others

Post on 05-Dec-2021

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Lead Paint Inspection - BSTI

Lead Paint Inspection

Client: Private company, Kennett Square PA Description: Brownfield Science & Technology, Inc. (BSTI) provided technical lead assessment

services to the owner of a structure undergoing renovation. The structure was built in the late

18th century and required substantial renovation prior to occupation. Due to the age of the

structure, lead-based paint (LBP) was presumed to be present.

A lead paint inspection is a surface-by-surface investigation to determine whether there is

lead-based paint in a structure or child-occupied facility. Inspections can be legally performed

only by certified inspectors or risk assessors.

BSTI’s objectives where to help our client to understand the level of screening appropriate and

to provide documentation to guide the on-scene construction workers. After some careful

consideration, BSTI’s client opted for a modified lead-based paint inspection that incorporated

a combination of field screening and sample collection.

During the inspection, components in each room as well as some exterior components were

surveyed for the presence of LBP using a portable X-ray fluorescence (XRF) spectrum analyzer.

A total of 136 XRF paint readings were taken and catalogued using in-system data capture.

After testing with the XRF was completed, the inspector collected dust “wipe” samples to

determine the quantity of lead in the dust throughout the structure. The results of the XRF

testing confirmed that lead-based paint was present on both interior and exterior surfaces.

The dust wipe samples also showed that lead dust levels where present above EPA/HUD

guidelines.

As a result of the modified approach, the client was able to prioritize and scale mitigation activities to assure protectiveness of human health while maintaining their budget. BSTI was able to define the remaining, less significant risk factors within a context that was understood and therefore manageable to our client. Our client subsequently moved forward with their intended plans for the property.

Objective:

Provide actionable data mid-construction

to inform and prioritize lead-based paint

mitigation measures.

Services:

• Environmental Consulting

• Lead Paint Inspection

• Industrial Hygiene

• Lead Dust Sampling

Applied Science/ Equipment and

Materials:

• XRF Analyzer

• Lead Wipes

• Data interpretation