E Frame -100 A, Thermal Magnetic (480Y/277 Vac)
AmpRating
1-Pole277Vac —14,000 AIRion \lar- _ ce nnn AID
Requires1 SpacePlug-on
Catalog No. PriceBolt-on
Catalog No. Price
2-Pole480Y/277 Vac —14,000 AIR120/240 Vac — 65,000 AIR
Plug-onCatalog No. Price
Requires2 Spaces
Bolt-onCatalog No. | Price
3-Pole480Y/277V3C —14,000 AIR
240 Vac —65,000 AIR
Catalog No. Price
Wire Size(AWG)
Cu
WireTemp.
EH/EHB^ |̂ 15^^H 20^^H 25^^H 30^^H 35^^H 40•!/• 45•£• soKM so•jfl 70•£• 80m^m 90••• 1°°^^^™ ——
EH14015*EH14020AEH14025EH14030EH14035EH1 4040EH14045EH14050EH14060
$85.85.85.85.85.85.85.85.85.
EHB14015AEHB14020iEHB14025EHB14030EHB14035EHB14040EHB14045EHB14050EHB14060
$95.95.95.95.95.95.95.95.95.
EH24015EH24020EH24025EH24030EH24035EH24040EH24045EH24050EH24060
$214.214.214.214.214.214.214.214.214.
EHB24015EHB24020EHB24025EHB24030EHB24035EHB24040EHB24045EHB24050EHB24060EHB24070TEHB24080T
EHB24100»
$243.243.243.243.243.243.243.243.243.
480.480.480.480.
EH34015EH34020EH34025EH34030EH34035EH34040EH34045EH34050EH34060
$387.387.387.387.387.387.387.387.387.
EHB34015EHB34020EHB34025EHB34030EHB34035EHB34040EHB34045EHB34050EHB34060EHB34070TEHB34080T
EHB34100T
$425.425.425.425.425.425.425.425.425.
578.578.
578.
#12-#8#12-#8#12-#2#12-#2#12-#2#12-#2#12-#2#4-#2/0itA #2/0
#4-#2/0
(2)-#14-#10(2)-#14-#10
#14-#8#14-#8#14-#2#14-#2#14-#2#14-#2#14-#2#4-#2/01t<\ ff2/0#4-#2/0#4-#2/0
60/75°C60/75°C60/75°C60/75°C
75°C75°C75°C75"C75°C75°C75°C
75°C
EH/EHB HID Circuit Breakers — For Use on High Intensity Discharge Lighting Systems15202530
EH14015HIDAEH14020HID*EH14025HIDEH14030HID
94.94.94.94.
EHB14015HIDiEHB14020HID*EHB14025HIDEHB14030HID
108.108.108.108.
EH24015HIDEH24020HIDEH24025HIDEH24030HID
232.232.232.232.
EHB24015HIDEHB24020HIDEHB24025HIDEHB24030HID
259.259.259.259.
EH34015HIDEH34020HIDEH34025HIDEH34030HID
411.411.411.411.
EHB34015HIDEHB34020HIDEHB34025HIDEHB34030HID
449.449.449.449.
#12-#8#12-#8
(2)-#14-#10(2)-#14-#10
#14-#8#14-#8
60/75°C60/75°C60/75°C60/75°C
i UL Listed as SWD (switching duty) rated.• For use only in Series 3 or Series E1 panelboards. Contact your nearest Square D/Schneider Electric sales office tor use in earlier series panelboards
Electrical and mechanical accessories listed below are for use with GJL instantaneous-trip and thermal-magnetic circuitbreakers. All ac electrical accessories shown below are rated for 50/60 Hz.Field-installable Electrical Accessories for GJL Circuit Breakers
Shunt Trip forGJL Circuit Breaker
UndervoltageTrip forGJL Circuit Breaker
Accessory
Shunt Trip
Undervoltage Trip
Auxiliary Switch
Alarm Switch
Description
Trips the circuit breaker from a remote location bymeans of a trip coil energized from a separatecircuit. All shunt trips will operate at 55% or more ofrated voltage.
Trips the circuit breaker electrically when a controlcircuit falls below 35 to 70% of nominal voltage.(Not field adjustable.) Picks up at 35 to 85% ofnominal voltage. UVR must be energized in order toclose the circuit breaker.
Rated Voltage
AC 120208240277480
DC 2448
125250
AC 120208240277480
DC 2448
125250
CollBurden
50mA29mA25mA22mA13mA
250mA125mA48mA24mA50mA29mA25mA22mA13mA
250mA125mA48mA24mA
Monitors circuit breaker contact status and provides a remote signal indicating the circuit breakercontacts are OPEN or CLOSED. Ratings: 3A-600 Vac. 6A-480 Vac. 0.3A-250 Vdc, 0.8A-125 VdcUsed with control circuits and is actuated only when the circuit breaker has tripped.Ratings: 3A-600 Vac, 6A-480 Vac. 0.3A-250 Vdc, 0.8A-125 Vdc
CatalogNo.
GSAGSBGSCGSDGSHGSOGSPGSRGSSGUAGUBGUCGUDGUHQUOGUPGURGUS
AAC*
AACi
Price
$455.455.455.455.455.455.455.455.455.
455.455.455.455.455.455.455.455.455.
189.
189.
Field-installable External Accessories
Alarm/Auxiliary Switch forGJL Circuit Breaker
DIN Rail AdapterTerminal Shields
Padlock Attachment
Cover Screw Seal
Hardware that allows mounting on standard 35 mm DIN rail.Used to prevent accidental contact with live parts.Prevents access to unauthorized personnel. Locks in OFF position only.Suitable for padlock with a shaft diameter up to 0.312 in. (8 mm).(10) Cover Screw Seals to prevent unauthorized removal of circuit breaker cover.
GYRGYT
AHP
ACS
59.0047.60
12.50
11.70
^ Same accessory - Application depends on installation location. Switch has common and both normally open and normally closed contacts.
6-36© 2000 Square DAll Rights Reserved
DE2 DiscountSchedule
Square D
www.squared.comFOR CURRENT INFORMATION
Selection InformationClass 500, 600
QOM1 and QOM2 MainCircuit Breakers Multi 9 Supplementary Protectors EH Circuit Breakers EDB Circuit Breakers
Plug-on EH
BreakerType Bolt-on QOM1-VH QOM2-VH EHB EDB EGB EJB
Unit Mount C60N* NC100H*
Number of Poles 3,1 3,4 3,4 2,3 2,3 2,3
Current Range 100-225 0.5-63 1-63 1-63 10-40 50-80 1CMO 50-80 10-4050-80 15-60 15-
10015-100 15-70 15-
125 15-70 15- 15-70 15-
Interrupting Ratings
UL7CSARating(kA RMS)(50/60 Hz AC)
DC Ratings
IEC 947-2(50/60 Hz AC)
120 Vac
120/240 Vac
240 VaCT
277Vac
480Y/277V3C
48VdC
65Vdc
125Vdc
250 Vdc
IEC(UltimateRating)
22
22
22
22
10
10
10
5
10
10
10 at240V
10
10
10
5
5
10
10
10
10 at240V
5 at415V
10
10
10
5
5
10 at240V
Sat415V
20
20
20
10
10
10
10
20 at240V
5
5
5
10
10
10 at240V
20
20
20
10
10
10
10
10
10
20 at240V
10at415V
5
5
5
10
10
10
20 at240V
10 at415V
20
20
20
10
10
10
10
10
10
20 at240V
10 at415V
5
5
5
10
10
10
20 at240V
10 at415V
65
14
14
65
65
14
14
14
65
65
65
14
14
25
18
18
18
25
25
25
18
18
65
35
35
35
65
65
65
35
35
100
65
65
65
100
100
100
65
65
Special RatingsFed. Specs W-C-375B/GEN
Other Standard
. . .
IEC, VDE IEC, VDE
/ / / / /
HACR, NOW
Accessories and ModificationsShunt Trip
Auxiliary SwitchesAlarm Switch
Handle Padlock Attachment /
/•
/
/
/
/
/
/
J
/
/
/
/
/
/
/
/
^
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/•
/•
/•
/
/•
/•
/•
/
/•
/•
/•
/
/•
/•
/•
/
/•
/•
/•
/
/•
/•
/•
/
/•
/•
/•
/
/•
/•
/•
/
/•
/•
/•
/
TOp System TypeThermal-Magnetic
Molded Case Switch
/ / / / / / / S / / / / / / / / / / / /
Dimensions (1P Unit Mount)
Dimensions(1P Unit Mount)
Height IN (mm)
Width IN (mm)
Depth IN (mm)
Pages (Unit Mount)/(l-LINE)
5.09(129)*5.00(127)*
3.47 (88)*
5.60(142)*
5.07(129)*
3.60(91)Page 1-7
3.19(81)
0.71 (18)
2.76 (70)
3.19(81)
1 .06 (27)
2.76 (70)
See 0600PL9701 and 0860CT9501
3.50 (89)
1.00(25)
2.97 (75)
Page 6-36
5.66(144)
0.98 (25)
4.05(103)Page 8-1 7
T For information regarding 3 phase corner grounded systems see Supplemental Digest.• Factory installed option only• C60N and NC100H are recognized components per UL 1077.• QOM1 and QOM2 dimensions are for 2-pole unit.
I-LINE is a Registered Trademark of Square D Company or related companies.
3/00© 2000 Square D
All Rights Reserved 6-3