Do you need to improve the visibility of your plant? Have you got outdated and unsupported SCADA systems which need upgrading? Or Do you simply want an overview of the world's most popular SCADA Software? Webinar Content: Overview and History of InTouch System Architecture Options Latest Version Features Upgrading your InTouch Licensing

TRANSCRIPT

Page 1: InTouch HMI SCADA

Wonderware Interactive Webinar Series

Helping you see more clearly

Wonderware InTouch®

Paul Edwards

Page 2: InTouch HMI SCADA

Agenda

► InTouch History

► Workflow

► Licensing

► Upgrading

► Case Studies

Page 3: InTouch HMI SCADA

What is it and What does it do?

► Wonderware InTouch is a software package to allow you to interact with and visualize data from you instruments and plant devices. The data is presented in a format relevant to your specific site and requirements.

► Wonderware InTouch runs under Microsoft Operating Systems and acquires data through protocol converters know as DAServers (aka IO Servers).

► Wonderware software is used in over a third of the worlds manufacturing facilities – that’s 100,000 plants and have sold over 0.5 million licenses.

Page 4: InTouch HMI SCADA

InTouch – a History

► A Brief History of Wonderware Visualization

1987

2.0

1995

5.6

1999

6.0

2000

7.0

2001

7.11

2003

8.0

2004

9.0

2005

9.5

2007

10.0

2009

10.1

Innovation

Functionality

Sophistication

Compatibility

Page 5: InTouch HMI SCADA

Connectivity

► InTouch native communications are Suitelink or DDE.

► OPC communications supported using FSGateway (free to use server).

► In order to communicate to PLCs then Wonderware produce IO Server programs.

► If PLC not supported then partner with Kepware for a special Kepware for Wonderware driver suite.

► If still not available write your own with DAServer Toolkit.

Page 6: InTouch HMI SCADA

InTouch Project Workflow

Decide on Architecture

Create Blank Application

Create Tag Database

Define Access Names, Security, History and Alarm

Groups

Create Mimics

Create Scripts

Configure Alarm Logging/Printing

Run Application

Page 7: InTouch HMI SCADA

InTouch Project Workflow

Decide on Architecture

Create Blank Application

Create Tag Database

Define Access Names, Security, History and Alarm

Groups

Create Mimics

Create Scripts

Configure Alarm Logging/Printing

Run Application

Page 8: InTouch HMI SCADA

Architectures – Peer to Peer

AdvantagesSingle Application across all machines (only 1 to manage)

DisadvantagesMay be higher licensing costsHarder to keep alarms/setpoints synchronised.

Page 9: InTouch HMI SCADA

Architectures – Shared IO

Server(s)

AdvantagesSingle application across all machines (only 1 to manage)Reduced licensing costsCan offload IO processing in large systemsDisadvantagesHarder to keep alarms/setpoints synchronised.Extra PCs to manage

Page 10: InTouch HMI SCADA

Architectures – Tagserver/Client

AdvantagesMay be reduced licensing costs in large systemsEasy to synchronise alarms and setpointsLower bandwidth usage by clientsDisadvantages2 applications to manageExtra PCs in system

Page 11: InTouch HMI SCADA

InTouch Project Workflow

Decide on Architecture

Create Blank Application

Create Tag Database

Define Access Names, Security, History and Alarm

Groups

Create Mimics

Create Scripts

Configure Alarm Logging/Printing

Run Application

Page 12: InTouch HMI SCADA

InTouch Application Manager

Page 13: InTouch HMI SCADA

InTouch Project Workflow

Decide on Architecture

Create Blank Application

Create Tag Database

Define Access Names, Security, History and Alarm

Groups

Create Mimics

Create Scripts

Configure Alarm Logging/Printing

Run Application

Page 14: InTouch HMI SCADA

InTouch WindowMaker

Page 15: InTouch HMI SCADA

InTouch Data Access

Page 16: InTouch HMI SCADA

InTouch Security

Page 17: InTouch HMI SCADA

InTouch History

Page 18: InTouch HMI SCADA

InTouch Alarm Groups

32 Levels of Alarms

Page 19: InTouch HMI SCADA

InTouch Project Workflow

Decide on Architecture

Create Blank Application

Create Tag Database

Define Access Names, Security, History and Alarm

Groups

Create Mimics

Create Scripts

Configure Alarm Logging/Printing

Run Application

Page 20: InTouch HMI SCADA

InTouch Tagname Database

Page 21: InTouch HMI SCADA

InTouch Tagname Database Bulk

Handling

Page 22: InTouch HMI SCADA

InTouch Project Workflow

Decide on Architecture

Create Blank Application

Create Tag Database

Define Access Names, Security, History and Alarm

Groups

Create Mimics

Create Scripts

Configure Alarm Logging/Printing

Run Application

Page 23: InTouch HMI SCADA

InTouch Mimics

• Mimics can be imported/exported

• Symbols can be centrally managed and changed using the Smart Symbols

• Tags can be created ‘on the fly’ when animating shapes

• Zoom facility is available in design time as well as full screen mode

• Links can be copied and pasted as well as shapes

• Grid can be configured to be turned on and off as well as snapped to

• Configuration can be printed out to text file or printer. Cross reference facility also exists.

• ActiveX objects can be put onto screens

Page 24: InTouch HMI SCADA

InTouch Project Workflow

Decide on Architecture

Create Blank Application

Create Tag Database

Define Access Names, Security, History and Alarm

Groups

Create Mimics

Create Scripts

Configure Alarm Logging/Printing

Run Application

Page 25: InTouch HMI SCADA

InTouch Scripting

Types of scripts:-ApplicationConditionData ChangeKeyQuickscriptsActiveXWindowAction

Scripting language based on Basic

Additional script functions are available from WDN website.

Script functions cover many requirements including file processing, SQL, controlling other programs and string manipulation.

Page 26: InTouch HMI SCADA

InTouch Scripting

Page 27: InTouch HMI SCADA

InTouch Project Workflow

Decide on Architecture

Create Blank Application

Create Tag Database

Define Access Names, Security, History and Alarm

Groups

Create Mimics

Create Scripts

Configure Alarm Logging/Printing

Run Application

Page 28: InTouch HMI SCADA

InTouch Alarm Logging

Page 29: InTouch HMI SCADA

InTouch Alarm Printing

Page 30: InTouch HMI SCADA

InTouch Project Workflow

Decide on Architecture

Create Blank Application

Create Tag Database

Define Access Names, Security, History and Alarm

Groups

Create Mimics

Create Scripts

Configure Alarm Logging/Printing

Run Application

Page 31: InTouch HMI SCADA

InTouch Licensing

• Every session/instance of InTouch must be licensed whether that instance is running on a remote computer or on the Terminal Server as a session or as a Service on the Console.

• InTouch is licensed by tag count

• Runtime tag count sizes 64, 500, 1k, 3k, 60k.

•OEM runtime tag counts of 256, 2K, 5K, 10K also available (requires OEM agreement)

• With or without IO allows you to use any number of Wonderware IO Servers on that node

• Development license in similar sizes as well as consignment licenses for SIs/OEMs.

Page 32: InTouch HMI SCADA

Architectures – Peer to Peer

5 off 60K Tag with I/O

Page 33: InTouch HMI SCADA

Architectures – Shared IO

Server(s)

5 off 60K Tag without I/O

1 off I/O ServerWonderwareKepwareKepware for WonderwareMatrikonRSLinx etc

Page 34: InTouch HMI SCADA

Architectures – Tagserver/Client

5 off 60K Tag without I/O

1 off 60K tag with I/O

Page 35: InTouch HMI SCADA

InTouch Licensing FAQs

• InTouch V10.1 license will run InTouch V10.0 and V10.1

• InTouch V9.5 license will run V5.6 up to V9.5

• Development license includes V10.1 and V9.5 licenses.

•Development license also includes a runtime license (but not for consignment).

• Development license includes an IO server license (to be used on the same node).

• Upgrades are included with Customer First.

• Any version of license can be upgraded to latest version.

• Licenses can be functionally upgraded (tag size, IO servers), but functional downgrade not possible (e.g. with I/O to without I/O)

Page 36: InTouch HMI SCADA

InTouch Upgrade Steps

Is applicationbefore V7.11?

Convert to V7.11

Reformat alarmscreens

Convert to latest version

Check for script add-ons

Revalidate all scripts

Backup application

Run and test application

Yes

No

Page 37: InTouch HMI SCADA

What Is New in InTouch 10

Page 38: InTouch HMI SCADA

ArchestrA Graphics

New Graphics for efficient:

- Engineering- Operation- Information display

► Vector based Graphics

► Advanced Features▪ Smoothing, Transparencies, Fills –

Gradients, Patterns, Textures

▪ Group Editing, Rotation anchors

► Named Elements▪ Every Graphic Primitive has a name

► More Animations▪ Better, more sophisticated animation

configuration

► Intelligent Applets▪ Scriptable

▪ Custom Properties

► Supports .NET Controls

► Runtime language switching in V10.1

Page 39: InTouch HMI SCADA

ArchestrA Symbol Library

and more…!!

Page 40: InTouch HMI SCADA

► Classic vs. Project View▪ New View/

Organisation Methods

• New Project View

• Structured by Folders

• Hierarchical Window and

Script Organisation

• Added Project context

and documentation tool

• Manage your projects

just like you manage

your folders

WindowMaker Changes

Page 41: InTouch HMI SCADA

► Easily enforce and maintain standards for data quality throughout your applications

► Standard across all ArchestrA graphics▪ Bad,Uncertain▪ Communication Error▪ Configuration Error▪ Operational Error▪ Software Error▪ Security …and more

Built-in Quality and Status

Indication

Page 42: InTouch HMI SCADA

► Runtime Language Switching▪ Alarm Comment Language Switching

• Accessed from Language menu

► Alarm Viewer Control▪ New Property and Event

• New Alarm Event

• Raised when any new alarm is detected

• Capability to detect new Industrial Application Server alarms

(or any other external alarm provider)

• Controls when New Alarm events are raised

InTouch 10 Enhancements

Page 43: InTouch HMI SCADA

► OS Managed multiple monitors▪ Maximize behaviour – maximizes across all

screens

▪ Input Dialogs appear on correct screen

▪ Popups, Overlays, Replace work as they should

▪ ShowAt(), DialogStringEntry() etc. -Keyboards appear where they should

Enhanced Multi-monitor Support

Page 44: InTouch HMI SCADA

► Operating Systems supported (minimum SPs)

▪ Windows XP SP3

▪ Windows 2003 Server SP2

▪ Windows Vista• Business, Enterprise, Ultimate

► Improved Terminal Server Edition Capability▪ Up to 75 clients supported▪ (before 25)

System Requirements/Improved

Compatibility

Page 45: InTouch HMI SCADA

Wonderware Development Studio

Plant Floor

Enterprise

HMI/Supervisory TSE

MES/P&PM

One Powerful Wonderware Development Studio For all Plant Needs

Common Repository

Application Server & Modules

InTouch 10.0Terminal Services/

Web / PDA

InTouch 10.0for Sys. Platform

Historian

Wonderware Compact Panels

InTouch 10.0Bundled TPC

Page 46: InTouch HMI SCADA

New Application Types

Stand Alone InTouch Applications

Managed InTouch Applications

Published InTouch Applications

Page 47: InTouch HMI SCADA

Just Released!

Service Pack 2 for InTouch 10.1• Support for Windows 2008 Server SP2 (not R2) 32 & 64 bit• Support for Windows Vista SP2 Business, Enterprise, or Ultimate 32 & 64 bit• Existing O/S still supported (see compatability list in WDN)• SQL Server 2008 SP1 32 bit only• Windows 7 supported at a later date.

Page 48: InTouch HMI SCADA

Case Studies

Page 49: InTouch HMI SCADA

Many...

►Almost every Wonderware sale includes InTouch

►It is the universal visualisation that is the hallmark of the portfolio

►Picking one would be to dismiss the characteristics and benefit of the others...

Page 50: InTouch HMI SCADA

The experience of case studies

▪ The higher the graphical quality, the more intuitive a process is to operate

▪ Involve process operators in the design of the interface

▪ Consider aspects of colour-blindness

▪ Bring disparate parts of the process together on one screen – avoiding wasteful walking from one part of the plant to another

▪ Structure standard ‘objects’ so that they become a company library

Page 51: InTouch HMI SCADA

The experience of case studies (2)

▪ Remember to visualise non-operation aspects, such as maintenance status

▪ Add an energy consumption data area on each screen

▪ Consider the integration of CCTV video

▪ Consider Terminal Services architecture

▪ Consider the true SCADA supervisory level to fully integrate standalone automated machines

▪ Make full use of the data within a SCADA system for business information

Page 53: InTouch HMI SCADA

Success Stories

many case studies can be found at...

http://www.wonderware.co.uk/success-stories

Page 54: InTouch HMI SCADA

InTouch Training Available

► To gain more insight into InTouch:

► InTouch Starter Course

► InTouch Intermediate Course

► InTouch Fast Track

► InTouch Networking

► InTouch Alarming

► InTouch ArchestrA

► InTouch Scripting

► InTouch for System Platform

► www.wonderware.co.uk/trainingwww.wonderware.ie/training

Page 55: InTouch HMI SCADA

Our WebEx series...

► Wednesday 10th

February► InTouch Compact

Edition

► Tuesday 16th

March► System Platform 4

– Whats New

Page 56: InTouch HMI SCADA

??Questions??

Page 57: InTouch HMI SCADA

Powering intelligent plant decisions in real time.