intellinox demand control kitchen...
TRANSCRIPT
![Page 1: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational](https://reader035.vdocuments.site/reader035/viewer/2022062306/5fb740749203fd0d223f140b/html5/thumbnails/1.jpg)
INTELLINOX DEMAND CONTROL KITCHEN VENTILATION
![Page 2: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational](https://reader035.vdocuments.site/reader035/viewer/2022062306/5fb740749203fd0d223f140b/html5/thumbnails/2.jpg)
AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292
COMMERCIAL KITCHEN VENTILATION EXPERTS
FOR OVER 25 YEARS
![Page 3: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational](https://reader035.vdocuments.site/reader035/viewer/2022062306/5fb740749203fd0d223f140b/html5/thumbnails/3.jpg)
• WE REALLY UNDERSTAND YOUR KITCHENExtensive knowledge with all kitchen hood manufacturers including design, installation, and sales of hood systems.
• WE KNOW ENERGY EFFICIENCYThe Intellinox commercial kitchen ventilation controls save energy, operational costs, and help contribute to a greener environment.
• WE REALLY UNDERSTAND AIR FLOW IN YOUR KITCHENNEBB certified testing, adjusting, and balancing firm –with a specialty in commercial kitchens.
WHO WE ARE
AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292
![Page 4: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational](https://reader035.vdocuments.site/reader035/viewer/2022062306/5fb740749203fd0d223f140b/html5/thumbnails/4.jpg)
ALL OR NOTHING VENTILATION
AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292
EXHAUST & MAKE-UP AIR
![Page 5: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational](https://reader035.vdocuments.site/reader035/viewer/2022062306/5fb740749203fd0d223f140b/html5/thumbnails/5.jpg)
• Addition of new components mean a solution for every commercial kitchen
• Multiple cooking modes yield lower average fan speeds
• Improved sensor durability & maintenance
• Lower cost on materials and installation
• Automatic on & off feature allows for greater energy savings
WHAT’S NEW WITH INTELLINOX?
AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292
![Page 6: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational](https://reader035.vdocuments.site/reader035/viewer/2022062306/5fb740749203fd0d223f140b/html5/thumbnails/6.jpg)
• Senses temperature changes in the hood & ductwork
• Used for both cooking & auto on / off capability
• Programmable temperature spans
• Ease of installation in hood ductwork or top of hood
• Available in both standard and EMT model
KEY COMPONENTS: TEMPERATURE SENSOR
AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292
![Page 7: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational](https://reader035.vdocuments.site/reader035/viewer/2022062306/5fb740749203fd0d223f140b/html5/thumbnails/7.jpg)
• Iris Blue Optical Sensors
• Sensing smoke & steam in the hood
• Blue Light is able to detect smaller smoke & steam particles
• Available in both standard & EMT model
• Ease of installation
• Auto calibration
• Ease of cleaning & responsiveness
KEY COMPONENTS: OPTIC SENSOR
AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292
![Page 8: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational](https://reader035.vdocuments.site/reader035/viewer/2022062306/5fb740749203fd0d223f140b/html5/thumbnails/8.jpg)
• Retrofitted into pre-existing ductwork
• Adjustable to fit existing conditions
• Fully-closed to fully-open in under 4 seconds
• Access panel installed when needed
• Responsible for additional energy savings
• Option on Intellinox-PLUS
KEY COMPONENTS: MODULATING DAMPER
AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292
![Page 9: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational](https://reader035.vdocuments.site/reader035/viewer/2022062306/5fb740749203fd0d223f140b/html5/thumbnails/9.jpg)
• YASKAWA Z1000with bypass
• YASKAWAwithout bypass
• ANY VFD MANUFACTURER WILL BE COMPATIBLE
VARIABLE FREQUENCY DRIVE (VFD) OPTIONS
AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292
![Page 10: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational](https://reader035.vdocuments.site/reader035/viewer/2022062306/5fb740749203fd0d223f140b/html5/thumbnails/10.jpg)
PUTTING IT ALL TOGETHER
AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292
![Page 11: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational](https://reader035.vdocuments.site/reader035/viewer/2022062306/5fb740749203fd0d223f140b/html5/thumbnails/11.jpg)
PUTTING IT ALL TOGETHER
AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292
![Page 12: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational](https://reader035.vdocuments.site/reader035/viewer/2022062306/5fb740749203fd0d223f140b/html5/thumbnails/12.jpg)
• Temperature sensors, Optic sensors & Modulating Dampers
• Prep Mode, Cooking Mode, Cooldown, & Idle
• Constant auto calibration of Optic sensors
• Automatic On, Off & sensor monitoring
• Ease of maintenance & cleaning
• Integration with Building Automation System
• Versatility of component installation
INTELLINOX KEY FEATURES
AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292
![Page 13: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational](https://reader035.vdocuments.site/reader035/viewer/2022062306/5fb740749203fd0d223f140b/html5/thumbnails/13.jpg)
• BOTH NEW CONSTRUCTION & RETROFIT
• ALL HOOD SIZES & TYPES
• ALL EXHAUST FANS & MAKE-UP AIR UNITS WITH 3-PHASE MOTORS
APPLICATIONS
AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292
![Page 14: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational](https://reader035.vdocuments.site/reader035/viewer/2022062306/5fb740749203fd0d223f140b/html5/thumbnails/14.jpg)
• 3.3.35.2 – Limited combustible material
• 7.3.4 – Access panel for dampers
• 7.5.4 – Devices with duct penetration listed UL1978
• 8.2.1.1 – Min air velocity 500ft/min in any duct
• 8.2.2.2 – Air balancing
• 8.2.2.3 – Lower exhaust air volume when not cooking
• 9.1.2 – Listed dampers permitted in ducts
CODES & REGULATIONS
AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292
• UL710 – Exhaust hoods for commercial equipment
• UL1978 – Grease ducts
• UL2017 – General-purpose signaling devices and systems
• CSA508A – Industrial control equipment
• NSF-2 – Commercial food equipment
• FCC part 15 subpart B –Unintentional radiators
• CE 2004/108/EC –Electromagnetic compatibility
STANDARDS & COMPLIANCE
![Page 15: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational](https://reader035.vdocuments.site/reader035/viewer/2022062306/5fb740749203fd0d223f140b/html5/thumbnails/15.jpg)
AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292
ENERGY STAR 2015EMERGING TECHNOLOGY AWARD
![Page 16: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational](https://reader035.vdocuments.site/reader035/viewer/2022062306/5fb740749203fd0d223f140b/html5/thumbnails/16.jpg)
• Average new fan speed of 65% (Temp & Optics)
• Average new fan speed of 50% (Temp, Optics & MD)
• Conditional air savings – Up to 70%
• Average payback – 1 to 3 years
• Improved Safety with auto on & off capability
• Improved Comfort with reduced hood air noise
• Sustainability by helping to achieve LEED credits
• Can qualify for local Utility Rebates
ENERGY SAVINGS & BENEFITS
AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292
![Page 17: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational](https://reader035.vdocuments.site/reader035/viewer/2022062306/5fb740749203fd0d223f140b/html5/thumbnails/17.jpg)
SCENARIO• Local restaurant
• 3 hoods
• 3 exhaust fans
• 16 hour / day runtime
• Retrofit
• Install time: 2 nights
CASE STUDY: RESTAURANT
AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292
![Page 18: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational](https://reader035.vdocuments.site/reader035/viewer/2022062306/5fb740749203fd0d223f140b/html5/thumbnails/18.jpg)
CASE STUDY: RESTAURANT
SCENARIO• Installed cost: $13,500.00
• Motor operating savings: $1,851.00/year
• Heating savings: $3,383.00/year
• Cooling savings: $1,971.00/year
TOTAL SAVINGS: $7,205.00/yearPAYBACK PERIOD: 1.9 years
AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292
![Page 19: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational](https://reader035.vdocuments.site/reader035/viewer/2022062306/5fb740749203fd0d223f140b/html5/thumbnails/19.jpg)
AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292
AIR SOLUTIONS & BALANCING
![Page 20: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational](https://reader035.vdocuments.site/reader035/viewer/2022062306/5fb740749203fd0d223f140b/html5/thumbnails/20.jpg)
• Offer complete turnkey installations of Intellinox systems
• All in-house labor by licensed electricians
• Complimentary walkthroughs & site visits
• In-house design engineering services
• Free energy analyses
• Over 10 years demand ventilation installation experience
• Hood performance testing
WHAT WE OFFER
AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292
![Page 21: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational](https://reader035.vdocuments.site/reader035/viewer/2022062306/5fb740749203fd0d223f140b/html5/thumbnails/21.jpg)
CONTACT AIR SOLUTIONS
CAMERON [email protected] 603-262-9292
USAbalancing.com40 King Street Unit 1, Auburn NH