implantology - dynamic abutment solutions en€¦ · has revolutionized the implantology sector,...

32
IMPLANTOLOGY

Upload: others

Post on 20-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

  • IMPLANTOLOGY

  • 2

    *Approval of total quality system assurance by notified body, according

    to Community legislation, for sterile and medical devices Class IIa.

    NOTE

  • 3

    4 DYNAMIC ABUTMENTS®

    6 ASTRA TECH / AQUA / LILAC

    7 NOBEL BIOCARE / BRANEMARK SYSTEM

    8 NOBEL BIOCARE / MULTI-UNIT / STANDARD

    9 NOBEL BIOCARE / REPLACE

    10 NOBEL BIOCARE / ACTIVE

    11 STRAUMANN / INTERNAL OCTOGON / SYNOCTA / BONE LEVEL

    12 ECKERMANN / ALL-SPIRAL / DUPLO

    13 BIOMET 3I / CERTAIN

    14 BIOMET 3I / OSSEOTITE

    15 BTI / INTERNAL CONNECTION

    16 BTI / EXTERNAL CONNECTION

    17 ZIMMER / SCREW-VENT

    18 KLOCKNER / NK2-SK2 / ESSENTIAL CONE

    19 PHIBO AND ANKYLOS

    20 DIO IMPLANT/ SM SYSTEM

    21 TEMPORAL 20º DYNAMIC ABUTMENT® OF PEEK

    22 DYNAMIC ABUTMENT® CONOMETRY / ANALYZER

    23 3.0 DYNAMIC ABUTMENT® SYSTEM FOR CAD-CAM

    24 3.0 DYNAMIC TITANIUM BASES AND SCAN BODY

    25 SYSTEM TORQUE

    26 ACCESSORIES / PROSTHETIC REAMER

    27 DEFINITIONS / INDICATIONS

    28 3.0 DYNAMIC ABUTMENT® SCREWS

    29 STRAIGHT ABUTMENT SCREWS

    30 GUARANTEE

    31 CONTACT

    INDEX

  • 4

    3.0 DYNAMIC ABUTMENTS®

    3.0 Dynamic Abutment® is an innovative solution which incorporates freedom of movement from 0º to 28º, to rectify angulation issues. It simplifies the prosthetic work, and most importantly, provides solutions.

    The 3.0 Dynamic Abutment® system is a unique and exclusive piece that has revolutionized the implantology sector, and it is the true alternative to titanium angulated abutments and to individual dies made by the technician. It is made up of two pieces connected together by an elbow that works as a joint, while the chimney pivots on the semi-spherical base. The Dynamic Abutment® system can rectify any angulation issues with millimetric precision up to 28º with full freedom of movement.

    REASONS FOR USING 3.0 DYNAMIC ABUTMENT®

    28º ANGUlATION FREEDOM

    Resolve angulation problems

    Improve the restoration function

    The function improves when applying the 3.0

    Dynamic Abutment® which allows for the anatomically reconstruction of the piece.

    Screwed final prosthesis

  • 5

    3.0 DYNAMIC ABUTMENT®

    Improve the aesthetics:

    Added thickness of ceramics

    Lack of space is a usual problem to place ceramics

    It can be resolvedby applying the 3.0Dynamic Abutment®

    No vestibular metallic edge

    Aesthetics problems in angulated solutions

    Ceramic grows from the implant applying 3.0 Dynamic Abutment®

    Cost reduction

    Speed

    Simplicity

    Application of 3.0 Dynamic Abutment® system in milled structures

    Correcting the screw output up to 30° with a more aesthetic finish.

    VIDEO3.0 DYNAMIC ABUTMENT®

  • 6

    COMPATIBlE WITH ASTRA TECHAQUA / lIlAC

    *See pag. 2

    TCOLBTCO15 N·cm

    TPDH1415 N·cm

    COMPLEMENTS

    45º C

    ON

    IC

    3,5 - 4,0/4,5-5,0

    ASTS45/T PCASTS45/P

    PD3ASTS45/T PD3ASTS45/P

    CLDES 1.20

    DSPDCLH-18/24/32PD: 18/24/32 mm

    RAST45

    TCOLBTCO15 N·cm

    COMPLEMENTS

    TPDH1415 N·cm

    20º C

    ON

    IC

    3,5 - 4,0/4,5-5,0

    ASTS20/T PCASTS20/P

    PD3ASTS20/T PD3ASTS20/P

    CLDES 1.20

    DSPDCLH-18/24/32PD: 18/24/32 mm

    RAST20

    4,5 - 5

    TAST2LBTAST230 N·cm RASTWP

    WID

    E PL

    ATFO

    RM

    ASTHWP/T PCASTHWP/P

    COMPLEMENTS

    3,5 - 4

    ASTHRP/T PCASTHRP/P

    PD3ASTRRP/PPD3ASTHRP/CC

    TAST16LBTAST1620 N·cm RASTRP

    COMPLEMENTS

    REG

    ULAR

    PLA

    TFO

    RM

    TPDH16L7620 N·cm DSPDCLH-18/24/32

    PD: 18/24/32 mm

  • 7

    COMPATIBlE WITH NOBEl BIOCAREBRANEMARK SYSTEM

    *See pag. 2

    COMPLEMENTS

    0,7

    0,7

    3,4

    5,1

    CLDES 1.30PCUCH51/PPCUCS51/P

    UCS51/T

    PD3UCH51/TPD3UCS51/T

    PD3UCH51/CCPD3UCS51/CC

    PD3UCH51/PPD3UCS51/P

    TUC25LBTUC2530 N·cm

    TPDH2525 N·cm

    TPDH25L6725 N·cm

    RUC51

    WID

    E PL

    ATFO

    RM

    DSPDCLH-18/24/32PD: 18/24/32 mm

    COMPLEMENTS

    4,1

    0,7

    0,7

    2,7

    CLDES 1.20CBS41/TPHECAL

    PROCALUCH41/TUCS41/T

    PD3UCH41/TPD3UCS41/T

    PD3UCH41/CCPD3UCS41/CC

    PD3UCH41/PPD3UCS41/P

    TUCLBTUC30 N·cm

    TPDH225 N·cm

    TPDH2L620 N·cm

    RUC41 REG

    ULAR

    PLA

    TFO

    RM

    DSPDCLH-18/24/32PD: 18/24/32 mm

    COMPLEMENTS

    0,7

    0,7

    2,4

    3,5

    UCS35/T CLDES 1.30PCUCH35/PPCUCS35/P

    PD3UCH35/TPD3UCS35/T

    PD3UCH35/CCPD3UCS35/CC

    PD3UCH35/PPD3UCS35/P

    TUC16LBTUC1620 N·cm

    TPDH1620 N·cm

    TPDH16L620 N·cm

    RUC35 NAR

    ROW

    PLA

    TFO

    RM

    DSPDCLH-18/24/32PD: 18/24/32 mm

  • 8

    COMPATIBlE WITH NOBEl BIOCARE

    MUlTI-UNIT

    STANDARD

    TSTLBTST15 N·cm

    REG

    ULAR

    PLA

    TFO

    RM

    0,8

    4,1

    2

    DSPDCLH-18/24/32PD: 18/24/32 mm

    CLDES 1.20PST41/T

    PD3ST41/T PD3ST41/P

    TPDHST15 N·cm

    TPDH1825 N·cmW

    IDE

    PLAT

    FORM

    6

    DSPDCLH-18/24/32PD: 18/24/32 mm

    PD3CO51/P

    TPDH1415 N·cm

    TCOLBTCO15 N·cm

    PD3CO41/T PD3CO41/CC PD3CO41/P

    COMPLEMENTS

    REG

    ULAR

    PLA

    TFO

    RM

    4,8

    CO41/T PCOCAL TIT-CO41-PRVCLDES 1.20

    DSPDCLH-18/24/32PD: 18/24/32 mm

    RMU48

    *See pag. 2

  • 9

    COMPATIBlE WITH NOBEl BIOCARE REPlACE

    COMPLEMENTS

    5,0CLDES 1.30RPLT50/T PCRPLT50/P RPLR50/T PCRPLR50/P

    TRPLLBTRPL30 N·cm RRPL50

    WID

    E PL

    ATFO

    RM

    *See pag. 2

    COMPLEMENTS

    COMPLEMENTS

    3,5

    RPLT35/T

    PD3UCH35BT/TPD3UCS35BT/T

    PD3UCH35BT/CC PD3UCS35BT/CC

    PD3UCH35BT/PPD3UCS35BT/P

    REBNP16 PIMEBNP16 TAPEB/PK

    PCRPLR35/P CLDES 1.30PCRPLT35/P RPLR35/T

    PD3RPLR35/PPD3RPLT35/CC

    TRPL35LBTRPL3525 N·cm

    TPDH1620 N·cm

    EBRPLNP25 N·cm

    TPDH18L7525 N·cm

    RRPL35

    NAR

    ROW

    PLA

    TFO

    RM

    DSPDCLH-18/24/32 PD: 18/24/32 mm

    DSEBNP:25mm

    COMPLEMENTS

    COMPLEMENTS

    RPLT43/T

    REBRP18 PIMEBRP18 TAPEB/PK

    PCRPLR43/PCLDES 1.30

    PCRPLT43/P RPLR43/T

    PD3UCH41/TPD3UCS41/T

    PD3RPLT43/CC** PD3RPLR43/P** **Angulation up to 20º

    PD3UCH41/CC PD3UCS41/CC

    PD3UCH41/PPD3UCS41/P

    TRPLLBTRPL30 N·cm

    TPDH1825 N·cm

    TPDH2L8225 N·cm

    EBRPLRP30 N·cm

    RRPL43

    DSPDCLH-18/24/32 PD: 18/24/32 mm

    DSEBRP:25 mm

    4,3

    REG

    ULAR

    PLA

    TFO

    RM

    Internal PD3.0: Divergence angle between implants up to 20°With convertor: Divergence angle between implants up to 26°

  • 10

    COMPATIBlE WITH NOBEl BIOCARE

    *See pag. 2

    TPDH16L7320 N·cm

    PD3ACTHNP/CC PD3ACTRNP/PDSPDCLH-18/24/32PD: 18/24/32 mm

    NAR

    ROW

    PLA

    TFO

    RM

    TPDH2L7525 N·cm

    PD3ACTHRP/CC PD3ACTRRP/PDSPDCLH-18/24/32PD: 18/24/32 mm

    REG

    ULAR

    PLA

    TFO

    RM

    ACTIVE

  • 11

    INTERNAl OCTOGON

    COMPATIBlE WITH STRAUMANN

    SYNOCTA

    COMPLEMENTS

    TPDH2L525 N·cm

    EBSYN30 N·cm

    TSYN48LBTSYN4830 N·cm

    REG

    ULAR

    PLA

    TFO

    RM

    4,8

    3

    1,47

    CO48/TCR48/T

    PD3CO48/TPD3CR48/T

    PD3CO48/PPD3CR48/P

    PCSYO48/PPCSYR48/P

    DESLCTORX:25mm

    CLDES 1.30

    DSPDCLH-18/24/32PD: 18/24/32 mm

    RSY48

    COMPLEMENTS

    TOCTLBTOCT30 N·cm

    REG

    ULAR

    PLA

    TFO

    RM

    4,8

    POCO48/T POCR48/TPCOCO48/P PCOCR48/P ROC48CLDES 1.30

    *See pag. 2

    BONE lEVEl

    PD3BONHNP/CC PD3BONRNP/P

    TPDH16L7820 N·cm

    NAR

    ROW

    PLA

    TFO

    RM

    DSPDCLH-18/24/32PD: 18/24/32 mm

    PD3BONHRP/CC PD3BONRRP/P

    TPDH16L7820 N·cm

    REG

    ULAR

    PLA

    TFO

    RM

    DSPDCLH-18/24/32PD: 18/24/32 mm

  • 12

    All-SPIRAl

    DUPlO

    4,56

    CLDES 1.25ECKDUC/T ECKDUR/TTECKDU125LBTECKDU12525 N·cmRE

    GUL

    AR P

    LATF

    ORM

    DSPDCLH-18/24/32PD: 18/24/32 mm

    4,56

    3,0

    2,3

    CLDES 1.25ECKALLC/TECKALLR/T

    PD3ECKALLC/T PD3ECKALLR/T

    TECKALL125LBTECKALL12525 N·cm

    TPDH18L4825 N·cm

    REG

    ULAR

    PLA

    TFO

    RMCOMPATIBlE WITH ECKERMANN

    *See pag. 2

  • 13

    COMPATIBlE WITH BIOMET 3I

    *See pag. 2

    COMPLEMENTS

    T3ILBT3I20 N·cm W

    IDE

    PLAT

    FORM

    5,0

    3IINTRWP/T PC3IINTHWP/PPC3IINTRWP/P R3IINT50

    CLDES 1.30

    CERTAIN

    TPDH1620 N·cm

    TPDH16L8420 N·cm

    EB3IRP25 N·cm

    T3ILBT3I20 N·cm

    REG

    ULAR

    PLA

    TFO

    RM

    4,0

    3IINTH/T3IINTR/T

    PD3UCH41/TPD3UCS41/T

    PD3IRRP/PPD3IHRP/CC

    PD3UCH41/CCPD3UCS41/CC

    PD3UCH41/PPD3UCS41/P

    PC3IINTHRP/PPC3IINTRRP/P

    DSEBRP:25mm

    CLDES 1.30

    DSPDCLH-18/24/32PD: 18/24/32 mm

    REBRP16 PIMEBRP16 TAPEB/PK

    R3IINT40

    COMPLEMENTS

    COMPLEMENTS

    Internal PD3.0: Divergence angle between implants up to 18°With convertor: Divergence angle between implants up to 26°

  • 14

    COMPATIBlE WITH BIOMET 3IOSSEOTITE

    COMPLEMENTS

    DSPDCLH-18/24/32PD: 18/24/32 mm

    5,0

    2,7

    0,7

    CLDES 1.20

    RUC50

    UCS50/T PCUCH50/PPCUCS50/P

    PD3UCH5O/T PD3UCS5O/T

    PD3UCH5O/P PD3UCS5O/P

    TUCLBTUC30 N·cm

    TPDH225 N·cm

    WID

    E PL

    ATFO

    RM

    COMPLEMENTS

    DSPDCLH-18/24/32PD: 18/24/32 mm

    4,1

    0,7

    0,7

    2,7

    CLDES 1.20CBS41/T

    RUC41

    UCH41/TUCS41/T

    PHECALPROCAL

    PD3UCH41/T PD3UCS41/T

    PD3UCH41/CC PD3UCS41/CC

    PD3UCH41/P PD3UCS41/P

    TUCLBTUC30 N·cm

    TPDH225 N·cm

    TPDH2L625 N·cm

    REG

    ULAR

    PLA

    TFO

    RM

    COMPLEMENTS

    TPDH2L6525 N·cm DSPDCLH-18/24/32

    PD: 18/24/32 mm3,3

    2,5

    0,7

    0,7

    CLDES 1.20

    RUC33

    UCS33/T

    PD3UCH33/T PD3UCS33/T

    PD3UCH33/P PD3UCS33/P

    PCUCH33/P PCUCS33/P

    TUCLBTUC30 N·cm

    TPDH225 N·cmN

    ARRO

    W P

    LATF

    ORM

    *See pag. 2

  • 15

    COMPATIBlE WITH BTIINTERNAl CONNECTION

    *See pag. 2

    COMPLEMENTS

    TBTILBTBTI25 N·cm

    WID

    E PL

    ATFO

    RM5,5

    BTIINTRWP/T PCBTIINTHWP/PPCBTIINTRWP/P

    RBT55CLDES 1.30

    TPDH1620 N·cm

    TPDH18L7525 N·cm

    EBBTIRP25 N·cm

    TBTILBTBTI25 N·cm

    REG

    ULAR

    PLA

    TFO

    RM

    4,1

    BTIINTH/T

    PD3UCH41/TPD3UCS41/T

    PD3BTIIRRP/PPD3BTIHRP/CC

    PD3UCH41/CCPD3UCS41/CC

    PD3UCH41/P PD3UCS41/P

    PCBTIINTHRP/P PCBTIINTRRP/PBTIINTR/T

    DSEBRP: 25mm

    CLDES 1.30

    DSPDCLH-18/24/32PD: 18/24/32 mm

    REBRP16 PIMEBRP16 TAPEB/PK

    RBT41

    COMPLEMENTS

    COMPLEMENTS

    Internal PD3.0: Divergence angle between implants up to 18° With convertor: Divergence angle between implants up to 26°

  • 16

    COMPATIBlE WITH BTIEXTERNAl CONNECTION

    COMPLEMENTS

    DSPDCLH-18/24/32PD: 18/24/32 mm

    5,5

    3,3

    1,1

    CLDES 1.30

    RUC55

    UCS55/T PCUCH55/PPCUCS55/P

    PD3UCH55/TPD3UCS55/T

    PD3UCH55/P PD3UCS55/P

    TSYN48LBTSYN4830 N·cm

    TPDH2L625 N·cm

    WID

    E PL

    ATFO

    RM

    COMPLEMENTS

    DSPDCLH-18/24/32PD: 18/24/32 mm

    4,1

    0,7

    0,7

    2,7

    CLDES 1.20

    CBS41/T

    RUC41

    UCH41/TUCS41/T

    PHECALPROCAL

    PD3UCH41/T PD3UCS41/T

    PD3UCH41/CC PD3UCS41/CC

    PD3UCH41/P PD3UCS41/P

    TUCLBTUC30 N·cm

    TPDH225 N·cm

    TPDH2L625 N·cm

    REG

    ULAR

    PLA

    TFO

    RM

    COMPLEMENTS

    DSPDCLH-18/24/32PD: 18/24/32 mm

    CLDES 1.30

    3,5

    2,5

    1,1

    1,1

    RUC35BT

    UCS35BT/T

    PD3UCH35BT/T PD3UCS35BT/T

    PD3UCH35BT/CC PD3UCS35BT/CC

    PD3UCH35BT/P PD3UCS35BT/P

    PCUCH35BT/P PCUCS35BT/P

    TSYN48LBTSYN4830 N·cm

    TPDH225 N·cm

    TPDH2L5125 N·cm

    NAR

    ROW

    PLA

    TFO

    RM

    *See pag. 2

  • 17

    COMPATIBlE WITH ZIMMERSCREW-VENT

    *See pag. 2

    TZIMLBTZIM25 N·cm W

    IDE

    PLAT

    FORM

    5,7

    PZIM57/T PCZIMH57/PPCZIMR57/P

    RZIM57CLDES 1.30

    COMPLEMENTS

    TAPEB/PK

    COMPLEMENTS

    TZIMLBTZIM25 N·cm

    TZIML76LBTZIML7625 N·cm

    TPDH1825 N·cm

    EBZIMNP30 N·cm

    NAR

    ROW

    PLA

    TFO

    RM

    3,5

    DSPDCLH-18/24/32PD: 18/24/32 mm

    CLDES1.30

    CLDES1.25

    DSEBNP:25mm

    RZIM35

    REBNP18 PIMEBNP18

    PZIM35/T PCZIMR35/P PCZIMH35/P

    PD3UCH35BT/TPD3UCS35BT/T

    PD3UCH35BT/CC PD3UCS35BT/CC

    PD3UCH35BT/PPD3UCS35BT/P

    PD3ZIMRNP/PPD3ZIMHNP/CC

    TPDH17L7125 N·cm

    COMPLEMENTS

    TPDH1825 N·cm

    TPDH17L7120 N·cm

    EBZIMRP30 N·cm

    TZIMLBTZIM25 N·cm

    REG

    ULAR

    PLA

    TFO

    RM

    4,5

    PZIM45/T

    PD3UCH41/TPD3UCS41/T

    PD3ZIMRRP/PPD3ZIMHRP/CC

    PD3UCH41/CCPD3UCS41/CC

    PD3UCH41/P PD3UCS41/P

    PCZIMH45/PPCZIMR45/P

    DSEBRP: 25mm

    CLDES 1.30

    DSPDCLH-18/24/32PD: 18/24/32 mm REBRP18 PIMEBRP18

    TAPEB/PK

    RZIM45

    COMPLEMENTS

    COMPLEMENTS

    Internal PD3.0: Divergence angle between implants up to 10°With convertor: Divergence angle between implants up to 26°

  • 18

    COMPATIBlE WITH KlOCKNER

    NK2-SK2

    ESSENTIAl CONE

    DSPDCLH-18/24/32PD: 18/24/32 mm

    4,2

    3,0

    1,8

    KLH42/TKLS42/T

    PD3KLH42/T PD3KLS42/T

    PD3KLS42/P

    TKLLBTKL25 N·cm

    TPDH1825 N·cm

    REG

    ULAR

    PLA

    TFO

    RM

    DSPDCLH-18/24/32PD: 18/24/32 mm

    4,5

    CLDES 1.30KLSSH45/T KLSSR45/T

    PD3KLSSH45/T PD3KLSSR45/T

    PD3KLSSR45/P

    TRPL35LBTRPL3525 N·cm

    TPDH18L4825 N·cm

    REG

    ULAR

    PLA

    TFO

    RM

    6,0

    CLDES 1.30KLSSR6/TTRPL35LBTRPL3525 N·cm

    WID

    E PL

    ATFO

    RM

    *See pag. 2

    Compatible with 12º Octacone

  • 19

    COMPATIBlE WITH PHIBO AND ANKYlOS

    PHIBO

    *See pag. 2

    ANKYlOS

    TPDH16L7620 N·cm

    TSA

    SERI

    E 3

    3,7

    PD3PHIHNP/T PD3PHIRNP/PRPHINPDSPDCLH-18/24/32

    PD: 18/24/32 mm

    COMPLEMENTS

    TPDH18L7525 N·cm

    TSA

    SERI

    E 4

    4,7PD3PHIHRP/T PD3PHIRRP/P

    RPHIRPDSPDCLH-18/24/32PD: 18/24/32 mm

    COMPLEMENTS

    TPDH1620 N·cm

    EBANK1525 N·cm

    EBANK3025 N·cm

    NAR

    ROW

    / R

    EGUL

    AR /

    WID

    E PL

    ATFO

    RM

    3,5 - 4,5 /5,5 - 7 DSPDCLH-18/24/32

    PD: 18/24/32 mm

    REBNP16 PIMEBNP16 TAPEB/PK

    PD3UCH35BT/T PD3UCH35BT/PPD3UCH35BT/CC

    PD3UCS35BT/T PD3UCS35BT/PPD3UCS35BT/CC

    DSEBRP: 25mm

    COMPLEMENTS

  • 20

    COMPATIBlE WITH DIO® IMPlANT

    DIO SM SYSTEM

    TPDH18L7525 N·cm

    3,8 - 4,1

    PD3DIOHNP/TPD3DIORNP/T

    PD3DIOHNP/CCPD3DIORNP/CC

    PD3DIORNP/PDSPDCLH-18/24/32PD: 18/24/32 mmN

    ARRO

    W P

    LATF

    ORM

    TPDH2L7425 N·cm

    4,5 - 5,0 - 5,3

    PD3DIOHRP/TPD3DIORRP/T

    PD3DIOHRP/CCPD3DIORRP/CC

    PD3DIORRP/PDSPDCLH-18/24/32PD: 18/24/32 mmRE

    GUL

    AR P

    LATF

    ORM

    WID

    E PL

    ATFO

    RM

    *See pag. 2

  • 21

    TEMPORARY 20° DYNAMIC ABUTMENT® OF PEEK

    The PEEK temporary abutments allow the immediate provisional elaboration of prostheses and restorations over implants.Through its base of PEEK, they are screwed directly on the implant being useful as base for a direct investment.The PEEK temporary abutments can be used either in dental office or laboratory.Note: Do not use it for casting.

    COMPATIBlE WITH BRANEMARK SYSTEM

    4,1

    2,7

    0,7

    PDUCS41/PKTPDH2L625 N·cm RE

    GUL

    AR P

    LATF

    ORM

    DSPDCLH-18/24/32PD: 18/24/32 mm

    COMPATIBlE WITH STRAUMANN SYNOCTA

    4,8

    3

    1,47

    PDCR48/PK

    TPDH2L625 N·cm RE

    GUL

    AR P

    LATF

    ORM

    DSPDCLH-18/24/32PD: 18/24/32 mm

    4,8

    PDCO41/PK

    TPDH14L5215 N·cm

    REG

    ULAR

    PLA

    TFO

    RMCOMPATIBlE WITH MUlTI-UNIT

    DSPDCLH-18/24/32PD: 18/24/32 mm

    *See pag. 2

  • 22

    CONOMETRY DYNAMIC ABUTMENT®

    20° DYNAMIC ABUTMENT® ANAlYZER

    ANPD16/PK ANPD18/PK ANPD20/PKANPD14/PK

    Set of 4 analyzer of the Dynamic Abutment® system made of PEEK, classified by metric, sterilizable, and compatible with most of the implants on the market. It allows an easy and quickly verification, either in

    the dental office or laboratory, to detect if the Dynamic Abutment® system will correct the aesthetic and functional problem.

    *See pag. 2

    TPDH225 N·cm

    PDUCH41C0/T

    Dynamic Abutment® with a milled die at 6º, indicated for over dentures and bridges.

  • 23

    3.0 DYNAMIC ABUTMENT® SYSTEMFOR CAD-CAM MIllED STRUCTURES

    DYN

    AMIC

    ABU

    TMEN

    T SC

    REW

    S 30

    º

    COMPATIBIlITY TABlE

    *See pag. 2

    TPDHST 15 N·cm

    TPDH25L67 25 N·cm

    TPDH16L78 20 N·cm

    TPDH14L52 15 N·cm

    TPDH16 20 N·cm

    TPDH16L73 20 N·cm

    TPDH16L76 20 N·cm

    TPDH14L39 15 N·cm

    TPDH14 15 N·cm

    TPDH16L6 20 N·cm

    TPDH2L5 25 N·cm

    TPDH2L51 25 N·cm

    25 N·cmTPDH18

    TPDH18L48 25 N·cm

    TPDH18L75 25 N·cm

    TPDH2 25 N·cm

    TPDH17L71 25 N·cm

    TPDH16L84 20 N·cm

    TPDH18L65 25 N·cm

    TPDH25 25 N·cm

    TPDH2L67 25 N·cm

    25 N·cmTPDH2L74

    TPDH2L82 25 N·cm

    TPDH2L90 25 N·cm

    TPDH2L65 25 N·cm

    TPDH2L6 25 N·cm

    TPDH2L75 25 N·cm

    DSPDCLH-18/24/32PD: 18/24/32 mm

  • 24

    3.0 DYNAMIC TITANIUM BASES AND SCAN BODYTO ANGUlATE IN CAD-CAM

    *See pag. 2

    COMPATIBlE WITH

    BRANEMARKTPDH2L6IND3UCS41/TiAIND3UCH41/TiA

    COMPATIBlE WITH

    MUlTIUNITTPDH14L39IND3CO41/TiA

    COMPATIBlE WITH

    REPlACETPDH2L90IND3RPLR43/TiAIND3RPLT43/TiA

    COMPATIBlE WITH

    STRAUMANN TPDH2L67IND3OCR48/TiAIND3OCO48/TiA

    COMPATIBlE WITH BTI TPDH18L65IND3BTIRRP/TiAIND3BTIHRP/TiA

    COMPATIBlE WITH

    ZIMMER TPDH17L71IND3ZIMR45/TiAIND3ZIMH45/TiA

    COMPATIBlE WITH DIO®

    TPDH2L74IND3DIORRP/TiAIND3DIOHRP/TiA

    COMPATIBlE WITH

    NOBEl ACTIVE TPDH2L75IND3ACTRRP/TiAIND3ACTHRP/TiA

    SCANBODY SBIND3OCRP/PKSBIND3RP/PKSBIND3MURP/PK

    Compatible with Multi-Unit Rest of compatibilities Compatible with Straumann

    REG

    ULAR

    PL

    ATFO

    RMRE

    GUL

    AR

    PLAT

    FORM

    REG

    ULAR

    PL

    ATFO

    RMRE

    GUL

    AR

    PLAT

    FORM

    REG

    ULAR

    PL

    ATFO

    RMRE

    GUL

    AR

    PLAT

    FORM

    REG

    ULAR

    /W

    IDE

    PLAT

    FORM

    REG

    ULAR

    PL

    ATFO

    RM

  • 25

    SYSTEM TORQUE

    SCREWDRIVERS

    MACHINED ABUTMENTS

    HEXAGON 1.20mmCLDES 1.20

    SQUARE 1.30mmCLDES 1.30

    HEXAGON 1.25mmCLDES 1.25

    DESLCTORX: 25mm

    HEXAGON 1.50mmCLDES 1.50

    DYNAMIC ABUTMENTS

    HEXALOBULAR 1.70 mmDSPDCLH-18: PD 18mm

    SCREWDRIVER EB NPDSEBNP: 25mm

    HEXALOBULAR 1.70 mmDSPDCLH-24: PD 24mm

    SCREWDRIVER EB RP DSEB: 25mm / DSEBRP: 25mm

    HEXALOBULAR 1.70 mmDSPDCLH-32: PD 32mm

    ADAPTOR TORQUE WRENCH

    MANUAL TORQUE WRENCH ADAPTER PROSTHETICMNADPCA

    UNIVERSAL MANUAL TORQUE WRENCH PROSTHETICCCUNI

    MANUAl HANDlE

    LARGE MANUAL HANDLE FOR LABORATORYMNLB

    MANUAL HANDLE FOR CLINICMNCL80

  • 26

    ACCESSORIES

    PROSTHETIC REAMER

    CHIMNEY REAMER

    BASE REAMER

    The casting process of the castable cylinders generates imperfections in the final metallic structure. In order to minimize the consequences generated by these process, Talladium have designed a new line of tools to correct the base of the cylinder, improving the interior of the chimneys and the adjustment on implant.

    Set of handle and reamerPESC

    ESXRP

    ESADNPMNES. Handle for reamer

    ESADRP

    ESCIM

    ESADWP

  • 27

    DEFINITIONS / INDICATIONS

    Castable Straight Abutment: Abutment made of plastic.

    Cast-to Straight Abutment in a Tilite milled base: Abutment with a Tilite base and castable chimney. Must be cast in Tilite alloy.

    Cast-to 3.0 Dynamic Abutment® with a Tilite milled base: Abutment which can be angled up to 28° to correct angles on implants placed in an incorrect position. With a Tilite base and must be cast in Tilite alloy. The maximum angulation can only be reached in the milled area. In NP up to a maximum of 25° and the rest of platforms to a maximum of 28°.

    Castable 3.0 Dynamic Abutment®: Fully castable abutment, to correct angulations on implants placed incorrectly. Can be angled up to 28°. The maximum angulation can only be reached in the milled area. In NP up to a maximum of 25° and the rest of platforms to a maximum of 28°.

    Cast-to 3.0 Dynamic Abutment® with a Cobalt-chrome milled base: Abutment which can be angled up to 28° to correct angles on implants placed in an incorrect position. With a Cobalt-chrome base and must be cast in Cobalt-chrome alloy. The maximum angulation can only be reached in the milled area. In NP up to a maximum of 25° and the rest of platforms to a maximum of 28°.

    Conometry Dynamic Abutment®: Dynamic Abutment® with a milled die at 6°, indicated foro ver dentures and bridges.

    PEEK temporary Dynamic Abutment®: Allows the immediate provisional elaboration of prostheses and restorations over implants. Do not use it for casting.

    Convertor 3.0 Dynamic Abutment®: Component within the Dynamic Abutment® System, made in Titanium, used to transform an internal connection to an external connection.

    Tilite Cylinder (CBS41): Cylinder in Tilite for use with Implant Bars

    Healing Cap EB (TAPEB): Healing of cicatrisation, only for EB.

    Titanium temporary abutment: Titanium abutment with retentions for the manufacturing of Titanium structures over implants.

    Clinical Screw: Titanium screw for the final fixture in patient’s mouth

    laboratory Screws: Titanium screw for the prosthesis manufacture, for use only in the laboratory.

    Square screwdriver: Screwdriver with square head of 1,30 mm.

    Hexagonal Screwdriver: Screwdriver with an hexagonal head of 1,20 - 1,25 - 1,50 mm.

    Dynamic 3.0 Abutment Screwdriver®: Screwdriver with ball shaped hexagonal head, exclusively for the 3.0 Dynamic Abutment® system.

    EB Screwdriver for 3.0 Dynamic Abutment®: The convertor´s Screwdriver for the Dynamic Abutment® system.

    Clinic Handle: Short stainless steel screwdriver handle for the dental surgeon.

    laboratory Handle: Long stainless steel screwdriver handle for laboratory use.

    Universal Manual Torque: Dynamometric manual torque wrench to tighten the clinical screws to the required Newtons.

    Manual Torque Adapter: Component that locates in the Universal Manual Torque´s connection (square), into which the screwdriver top is fitted.

    Replica: Implant replica made of stainless steel.

    Impression taking: Piece to take indirect impression over implants or converters.

    Analyzer: Dynamic Abutment® system analyzer, classified by metrics, allows verifying the angulation from 0 to 20 degrees of the implant.

    Reamer: Corrects the base of the cylinder, improving the adjustment over the implant and the interior of the chimneys.

    3.0 Dynamic Titanium Bases: Dynamic Titanium bases to angulate in cad /cam. Allows the correction of bad positioned implant.

    Scan Body: Scannable PEEK Base to reproduce the virtual position and orientation of the 3.0 Dynamic Titanium base in 3D

  • 28

    REFE

    REN

    CE

    MET

    RIC

    TORQ

    UE

    TOTA

    L LE

    NG

    TH

    THRE

    AD L

    ENG

    TH

    HEAD

    DIA

    MET

    ER

    A LE

    NG

    TH

    B LE

    NG

    TH

    C LE

    NG

    TH

    SETT

    LEM

    ENT

    ANG

    LE

    THRE

    AD E

    NTR

    Y

    CON

    NEC

    TIO

    N

    1,4 15 N·cm 3,9 1,8 2,4 2,1 - 1,8 straight - 45º chamfer

    Hexalobular 1,70

    1,4 15 N·cm 4 1,85 2,3 2 2,78 1,22 conical 30º 45º chamfer

    1,4 15 N·cm 4,5 2,3 2,3 2,5 3,28 1,22 conical 30º 45º chamfer

    1,4 15 N·cm 5,2 2,9 2,3 3,4 - 1,8 straight - 45º chamfer

    1,6 20 N·cm 4,4 2,5 2,3 2,9 - 1,5 straight - Semi-sphere

    1,6 20 N·cm 5,9 3 2,3 4,4 - 1,5 straight - Semi-sphere

    1,6 20 N·cm 7,3 2,2 2,3 4,87 5,56 1,74 conical 35º 45º chamfer

    1,6 20 N·cm 7,6 3,6 2,3 6,1 - 1,5 straight - Semi-sphere

    1,6 20 N·cm 7,8 2 2,3 5,36 7,03 0,81 conical 15º 45º chamfer

    1,6 20 N·cm 8,4 3,5 2,3 6,8 - 1,6 straight - Semi-sphere

    N1-72 25 N·cm 7,1 2,6 2,3 5,56 5,65 1,45 conical 70º 45º chamfer

    1,8 25 N·cm 4,4 2,75 2,3 3 - 1,4 straight - Semi-sphere

    1,8 25 N·cm 4,8 2,8 2,3 3,22 3,65 1,15 conical 30º Semi-sphere

    1,8 25 N·cm 6,5 3,3 2,4 5 - 1,5 straight - Semi-sphere

    1,8 25 N·cm 7,5 3,3 2,3 6,1 - 1,4 straight - Semi-sphere

    2 25 N·cm 4,7 3 2,3 3,3 - 1,4 straight - Semi-sphere

    2 25 N·cm 5 2,8 2,3 3,39 3,6 1,4 conical 30º Semi-sphere

    2 25 N·cm 5,1 3,1 2,3 3,6 - 1,5 straight - Semi-sphere

    2 25 N·cm 6 2,7 2,3 4,5 - 1,5 straight - Semi-sphere

    2 25 N·cm 6,5 2,7 2,3 5 - 1,5 straight - 45º chamfer

    2 25 N·cm 6,7 2,3 2,59 3,65 5,68 1,02 conical 15º 45º chamfer

    2 25 N·cm 7,4 3,3 2,3 6 - 1,4 straight - Semi-sphere

    2 25 N·cm 7,5 2,75 2,3 5,93 6,18 1,32 conical 35º 45º chamfer

    2 25 N·cm 8,2 4,7 2,4 6,7 - 1,5 straight - Semi-sphere

    2 25 N·cm 9 4 2,3 7,5 - 1,5 straight - Semi-sphere

    2,5 25 N·cm 5,4 3,8 2,85 4,1 - 1,3 straight - Semi-sphere

    2,5 25 N·cm 6,7 4,6 2,85 5,1 - 1,6 straight - Semi-sphere

    TPDH14L39

    TPDH14

    TPDHST

    TPDH14L52

    TPDH16

    TPDH16L6

    TPDH16L73

    TPDH16L76

    TPDH16L78

    TPDH16L84

    TPDH17L71

    TPDH18

    TPDH18L48

    TPDH18L65

    TPDH18L75

    TPDH2

    TPDH2L5

    TPDH2L51

    TPDH2L6

    TPDH2L65

    TPDH2L67

    TPDH2L74

    TPDH2L75

    TPDH2L82

    TPDH2L90

    TPDH25

    TPDH25L67

    3.0 DYNAMIC ABUTMENT® SCREWS FOR CAD-CAM

    *See pag. 2

  • 29

    REFE

    REN

    CE

    MET

    RIC

    TORQ

    UE

    TOTA

    L LE

    NG

    TH

    THRE

    AD L

    ENG

    TH

    HEAD

    DIA

    MET

    ER

    A LE

    NG

    TH

    B LE

    NG

    TH

    C LE

    NG

    TH

    SETT

    LEM

    ENT

    ANG

    LE

    THRE

    AD E

    NTR

    Y

    CON

    NEC

    TIO

    N

    TCO

    TST

    TUC16

    TAST16

    T3I

    TKL

    TBTI

    TECKALL125

    TRPL35

    TECKDU 125

    TZIML76

    TZIM

    TSYN48

    TOCT

    TUC

    TRPL

    TAST2

    TUC25

    1,4 15 N·cm 4 2 2,3 2,2 - 1,8 straight - 45º chamfer 1,20 Hex.

    1,4 15 N·cm 3,9 1,91 2,4 2,1 - 1,8 straight - 45º chamfer 1,20 Hex.

    1,6 20 N·cm 7 2,79 2,3 4,86 5,44 1,56 conical 45º 45º chamfer 1,30 Squa.

    1,6 20 N·cm 8,25 3,03 2,45 6,25 - 2 straight - 45º chamfer 1,27 Hex.

    1,6 20 N·cm 9,3 3,3 2,3 7,3 - 2 straight - Semi-sphere 1,30 Squa.

    1,8 25 N·cm 6 3,18 2,4 3,5 3,85 2,15 conical 45º 45º chamfer 1,50 Hex.

    1,8 25 N·cm 7 3,2 2,5 5,2 - 1,8 straight - 45º chamfer 1,30 Squa.

    1,8 25 N·cm 7,2 4,47 2,4 2,3 6,2 1 conical 30º 45º chamfer 1,25 Hex.

    1,8 25 N·cm 10,2 3,15 2,45 8,4 - 1,8 straight - 45º chamfer 1,30 Squa.

    1,8 25 N·cm 9,8 5,094 2,4 8,3 8,8 1 conical 30º 45º chamfer 1,25 Hex.

    N1-72 25 N·cm 7,6 2,8 2,3 5,6 5,76 1,84 conical 70º 45º chamfer 1,25 Hex.

    N1-72 25 N·cm 8,17 3 2,4 5,31 5,87 2,3 conical 45º 45º chamfer 1,30 Squa.

    2 30 N·cm 5 3,06 2,49 3,26 3,5 1,5 conical 45º 45º chamfer 1,30 Squa.

    2 30 N·cm 7,45 3 2,4 5,7 5,9 1,55 conical 45º 45º chamfer 1,30 Squa.

    2 30 N·cm 7,4 3,34 2,4 5,1 5,6 1,8 conical 45º 45º chamfer 1,20 Hex.

    2 30 N·cm 10,2 3,15 2,45 8,4 - 1,8 straight - 45º chamfer 1,30 Squa.

    2 30 N·cm 10,3 4 2,45 8,3 - 2 straight - 45º chamfer 1,27 Hex.

    2,5 30 N·cm 7,41 3,5 2,87 4,75 5,29 2,12 conical 45º Semi-sphere 1,30 Squa.

    DESCRIPTION OF STRAIGHT ABUTMENT SCREWS

    *See pag. 2

    Thread Length

    Settlement

    Connection

    Thread Entry

    Length A

    Total Length

    Length C

    Head

    Ø

    Thread LengthAngle

    Connection

    Thread Entry

    Length ALength BLength C

    Total Length

    Head

    Ø

  • 30

    TAllADIUM GUARANTEE

    TERMS AND CONDITIONSThese guarantee terms and conditions (“T&C”) cover the entire range of Talladium España SL products (“Products”), that are manufactured by Talladium España SL and distributed by Geoda Medical, SL or its official dealers.The guarantee described in these T&C’s is exclusively for the benefit of the clinician (“Clinician”) and of the dental technician (“Technician”) and not for the benefit of any third parties, institutions or patients.

    GUARANTEE PERIODTalladium España SL offers a lifetime guarantee for its entire range of products.

    GUARANTEE SCOPESubject to the limitations and exceptions described in these T&C’s, Talladium España SL will offer the following benefits:QUALITY- If there are defects in the materials or in the manufacturing of the product, Talladium España SL will replace the product at no additional cost.SAFETY- If all instructions for use have been observed and the prosthesis needs to be remade due to the fault of the Dynamic Abutment® System, Talladium España SL will replace the abutments and screws that are necessary to remake the prosthesis at no cost. Talladium España SL will reimburse the costs of manufacture for such prosthesis.

    CLAIM REQUIREMENTS AND PROCEDURETo receive the benefits indicated in these T&C’s, the treating Clinician must satisfy the following requirements:1) The clinician or technician must contact the customer service department to make the claim2) A completed claim form must be sent with the faulty product to Talladium España SL’s office.3) Clinicians and Technicians presenting a claim in agreement with these T&C’s must be up to date on any payments that are due.4) All procedures must be used in accordance with Talladium España SL’s instructions, as well as in accordance with common dentistry practices.The return shipping costs will be assumed by Talladium España SL in all of the cases covered by these T&C’s.

    GENERAL LIMITATIONS OF THIS GUARANTEEWith the exception of the guarantee described in these T&C, neither Talladium España SL nor its representatives, nor third parties manufacturing or distributing the Products, represent or offer a guarantee, agreement or any other express or implicit, oral or written, commitment, with respect to the Products (without limitation), including guarantees involved in the marketing, durability or suitability for individual uses or purposes.In addition and within the maximum extent permitted by the relative law, Talladium España SL rejects (on its own behalf, and on behalf of its representatives and third parties that manufacture or distribute Products) any responsibility with respect to any direct or indirect damage caused, which may result from or be a consequence of the design, composition of the dental prosthesis into which the Products are integrated.

    GUARANTEE EXCLUSIONS- Talladium España SL limits this guarantee to:- Transformed abutments that form part of the dental prosthesis. But not the screws used to anchor them.- Problems derived from the use of laboratory screws for the definite fixation of the prosthesis. Talladium España SL has sterile clinical screws that satisfy that function.- Clinical screws that have been in the mouth for more than 2 years, as it is understood that the patient has to have annual check-ups with the subsequent change of screws.- The fault is due to normal wear and tear.

    AMENDMENT OR SUSPENSION OF THE GUARANTEETalladium España SL reserves the right to amend or withdraw these T&C at any time and without prior notification. Any modification or suspension shall not affect products already installed in patients.

  • 31

    Each and every commercial trademark mentioned on this catalogue are fully registered by their respective companies, the appearing images are just to provide an orientations.Talladium reserves the rigth to modify this document without previous notice.Talladium is not responsible for the adequate execution of this products if the warning indications corresponding to every reference are not contemplated.

    AV. MADRID 17, ALTILLO 1ª25002 LLEIDA (SPAIN)

    TEL. +34 973 289 [email protected]

  • www.dynamicabutment.com

    ENG

    - e

    ditio

    n 20

    14/1