    Hydro-unitTechnical data Premium line

    series: Hydro-Unit DPV(M)E

    Hydro-unit HR DPV(M)E

    Hydro-unit FR DPV(M)E

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    2/64

    2

    Table of Contents

    1 Introduction1.1 Abbreviations.........................................................................................................................................4

    1.2 Range ....................................................................................................................................................4

    1.3 Working range........................................................................................................................................ 4

    1.4 Basic materials....................................................................................................................................... 4

    1.5 Approvals...............................................................................................................................................4

    1.6 Model code ............................................................................................................................................5

    2 Performance graphs2.1 Performance range 50 Hz......................................................................................................................6

    2.2 Performance (FR) range 60 Hz.............................................................................................................. 7

    2.3 Performance with variable frequency drive............................................................................................8

    2.4 How to read the values from the curves ................................................................................................ 9

    2.5 Hydraulic performance curve DPV(M)E2 (50 Hz ~2850 rpm) (1 pump in operation).......................... 10

    2.6 Hydraulic performance curve DPV(M)E2 (60 Hz ~3450 rpm) (1 pump in operation)...........................11

    2.7 Hydraulic performance curve DPV(M)E 4 (50 Hz ~2850 rpm) (1 pump in operation)......................... 12

    2.8 Hydraulic performance curve DPV(M)E 4 (60 Hz ~3450 rpm) (1 pump in operation)......................... 13

    2.9 Hydraulic performance curve DPV(M)E 6 (50 Hz ~2850 rpm) (1 pump in operation)......................... 14

    2.10 Hydraulic performance curve DPV(M)E6 (60 Hz ~3450 rpm) (1 pump in operation).......................... 15

    3 Speci fication3.1 Dimensions and weights HU standard................................................................................................. 18

    3.1.1 HU2 DPV(M)E2/4/6 DPC DOL .................................................................................................18

    3.1.2 HU2 DPVE2/4/6 DPC DOL.......................................................................................................20

    3.1.3 HU2 DPVE10 DPC DOL...........................................................................................................22

    3.1.4 HU3 DPV(M)E2/4/6 DPC DOL .................................................................................................24

    3.1.5 HU3 DPVE2/4/6 DPC DOL.......................................................................................................26

    3.1.6 HU3 DPVE10 DPC DOL...........................................................................................................28

    3.1.7 Specification text.......................................................................................................................30

    3.2 Dimensions and weights HU HR installation (incl. WSD).....................................................................32

    3.2.1 HU2 DPV(M)E2/4/6 HR ............................................................................................................ 32

    3.2.2 HU2 DPVE2/4/6 HR .................................................................................................................34

    3.2.3 HU2 DPVE10 HR .....................................................................................................................36

    3.2.4 HU3 DPV(M)E2/4/6HR .............................................................................................................38

    3.2.5 HU3 DPVE2/4/6 HR .................................................................................................................40

    3.2.6 HU3 DPVE10 HR .....................................................................................................................42

    3.2.7 Specification text.......................................................................................................................44

    3.3 Dimensions and weights HU MCMF (FR)............................................................................................46

    3.3.1 HU2 DPV(M)E2/4/6 MCMF ...................................................................................................... 46

    3.3.2 HU2 DPVE2/4/6 MCMF............................................................................................................ 483.3.3 HU2 DPVE10 MCMF................................................................................................................50

    3.3.4 HU3 DPV(M)E2/4/6 MCMF ...................................................................................................... 52

    3.3.5 HU3 DPVE2/4/6 MCMF............................................................................................................ 54

    3.3.6 HU3 DPVE10 MCMF................................................................................................................56

    3.3.7 Specification text.......................................................................................................................58

    4 Accessories4.1 Accessories HU 2/3 DPV(M)E .............................................................................................................59

    4.1.1 Mounting sets ...........................................................................................................................60

    4.1.2 Pressure reducing valves .........................................................................................................60

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    3/64

    3

    5 Annex5.1 Structure of article numbers.................................................................................................................63

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    4/64

    4

    1 Introduction

    1.1 Abbreviations

    1.2 Range

    1.3 Working range

    The working range of the installation can be

    summarised as follows:

    Table 1: Specification of the working range

    Table 2: Specific applications

    1.4 Basic materials

    1.5 Approvals

    Explanation

    HU Hydro-Unit

    DPC DP Control

    HR High Efficiency

    MCMF Megacontrol Multi- Frequency (each pump

    frequency driven)

    DOL Direct On Line

    AISI StainLess Steel

    G Gas thread

    NAP Normal Amsterdam Peil

    HU 2/3

    DOL

    DPV(M)E 2 DPV(M)E 4 DPV(M)E 6 DPVE 10

    PN10 /2 - /6 /2 - /6 /2 - /5 /2 - /5

    PN16 /7 - /11 /7 - /9 /6 - /9 /6

    HU 2/3

    DOL

    HR

    DPV(M)E 2 DPV(M)E 4 DPV(M)E 6 DPVE 10

    PN10 /2 - /8 /2 - /6 /2 - /6 /2 - /5

    Tank [l] 100 100 100 200

    HU 2/3

    MCMF

    DPV(M)E 2

    60 Hz!

    DPV(M)E 4

    60 Hz!

    DPV(M)E 6

    60 Hz!

    DPVE 10

    50 Hz!

    PN10 /2 - /5 /2 - /4 /2 - /4 /2 - /5

    PN16 /6 -/7 /5 - /6 /5 - /6 /6

    Type DP

    Ambient temperature [C] 0 - 30

    Liquid temperature [C] +4 - 401

    Maximum working pressure

    [kPa]

    1.600

    Unless indicated otherwise

    Supply pressure [kPa] Non-cavitating1.

    Minimum: 120 kPa

    Maximum: supply pressure

    plus pump pressure

    together may not exceed

    1600 kPa

    1. Contact your supplier for more detailed advice.

    Maximum height 1000 m above NAP

    Type Area of application

    HU PREMIUM

    LINE

    (Drinking) water supply systems, pres-

    sure increase in apartment buildings

    Item Hydraulic part Casting

    parts

    Sealing

    Pump 1.4301 1.4308 EPDM

    Non-return

    valve

    POM Rubber

    Shut-off valve 1.4301 1.4301

    Piping 1.4301

    Diaphragm

    vessel

    Stainless steel

    connection /

    epoxy coating

    Butyl rub-

    ber

    Pressure

    transmitter

    1.4305

    Drain Brass

    Misc. May contain brass

    parts

    VEWIN water wo rksheets

    CE Complies with the European Safety Directive

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    5/64

    5

    1.6 Model code

    Hydro-Unit

    Numbe

    rofpumps

    Pumpseries

    Typepump

    Numbe

    rofpressurestages

    Materia

    lsupplypipe

    Sizefittings

    Materia

    ldischargepipe

    Sizem

    anifold(suctionanddischarge)

    Pressu

    reclassofinstallation

    Rundryprotectionbymeansofpressureswitch

    Typeofcontrol:

    DOL=

    DirectOnLine

    DOLH

    R=withextradiaphragm

    vesselforhigheffi-

    ciency

    MCMF

    =frequencyinvertereachpump,output60Hzfor

    2/4/6a

    nd50Hzforthe10series

    Supply

    voltageandfrequency

    3x

    400V+N50

    Hz

    3x400V+N50

    Hz

    DPC

    DOL

    DPCDOL

    DPCDOLHR

    MCMF60Hz

    MCMF50Hz

    PS PS

    PN10

    PN10

    G6

    /4

    G6/4

    G2

    AISI304

    AISI304

    G1

    G1

    AISI304

    AISI304

    /2 /2.../6

    2 2 4 6 10

    DPVME

    DPV(M)E

    2 2 3

    HU

    HU

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    6/64

    6

    2 Performance graphs

    2.1 Per formance range 50 Hz

    Figure 1: Performance range DPV(M)E 2 / 4 / 6 / 10 50 Hz (3 pumps in operation)

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    7/64

    7

    2.2 Performance (FR) range 60 Hz

    Figure 2: Performance range DPV(M)E 2 / 4 / 6 60 Hz (3 pumps in operation)

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    8/64

    8

    2.3 Performance with variable frequency drive

    The minimum frequency of the DP motor should be

    limited to 10 Hz to ensure sufficient cooling. When the

    rotational speed exceeds the nominal speed of the

    motor, make sure that the power output of the motor

    is suitable to drive the corresponding pump model.

    The performance of the pump differs from the fixed

    speed performance according to the recalculation

    scheme.

    Figure 3: Performance characteristics 3238/08072008

    1

    1

    2

    2Q

    n

    nQ

    13

    1

    3

    2

    2P

    n

    nP

    12

    1

    2

    2

    2NPSH

    n

    nNPSH

    Q1 Q2

    1.0

    2

    1.0

    112 11

    nnKK

    12

    1

    2

    2

    2H

    n

    nH

    Q

    Q

    Q

    Q

    NPSHreq.

    P/st.

    Khydr.

    H

    n1

    n2

    n1n2

    n2

    n1

    n1

    n2

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    9/64

    9

    2.4 How to read the values from the curves

    To find the required hydraulic information from the

    published curves, it is important to know the

    application in which the pump has to be installed.

    There are two main distinction to be made:

    A Flow determined (like booster sets and

    cleaning) Opening taps

    B Pressure determined (like boiler feed and

    reverse osmosis systems) Facing counter

    pressure.

    O Calculated duty point

    z Actual hydraulic performance

    A Flow determined

    B Pressure determined

    Figure 4: How to read the values from the curves 3227/04072008

    Pump size / no of stages.

    Installed motor power

    Capacity @ Pressure

    NPSH (m)

    Hydraulic efficiency (%)

    Required power (P2)

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    10/64

    10

    2.5 Hydraulic performance curve DPV(M)E2 (50 Hz ~ 2850 rpm)

    (1 pump in operation)

    Figure 5: Performance curve DPV(M)E2 (50 Hz ~ 2850 rpm)

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    11/64

    11

    2.6 Hydraulic performance curve DPV(M)E2 (60 Hz ~ 3450 rpm)

    (1 pump in operation)

    Figure 6: Performance curve DPV(M)E 2 (60 Hz ~ 3450 rpm)

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    12/64

    12

    2.7 Hydraulic performance curve DPV(M)E 4 (50 Hz ~ 2850 rpm)

    (1 pump in operation)

    Figure 7: Performance curve DPDPV(M)E4 (50 Hz ~ 2850 rpm)

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    13/64

    13

    2.8 Hydraulic performance curve DPV(M)E 4 (60 Hz ~ 3450 rpm)

    (1 pump in operation)

    Figure 8: Performance curve DPV(M)E 4 (60 Hz ~ 3450 rpm)

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    14/64

    14

    2.9 Hydraulic performance curve DPV(M)E 6 (50 Hz ~ 2850 rpm)

    (1 pump in operation)

    Figure 9: Performance curve DPV(M)E 6 (50 Hz ~ 2850 rpm)

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    15/64

    15

    2.10 Hydraulic performance curve DPV(M)E6 (60 Hz ~ 3450 rpm)

    (1 pump in operation)

    Figure 10: Performance curve DPV(M)E 6 (60 Hz ~ 3450 rpm)

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    16/64

    16

    2.11 Hydraulic performance curve DPVE10 (50 Hz ~ 2880 rpm)

    (1 pump in operation)

    Figure 11: Performance curve DPVE10 (50 Hz ~ 2880 rpm)

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    17/64

    17

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    18/64

    18

    3 Specification

    3.1 Dimensions and weights HU standard

    3.1.1 HU2 DPV(M)E2/4/6 DPC DOL

    Figure 12: HU2 DPV(M)E2/4/6 DPC 20100136-A

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    19/64

    19

    Table 3: General

    Table 4: Detailed

    Control DPC DOL

    Run-dry protection Pressure Switch

    Connection voltage 3x400V+N 50Hz

    Insolation class IP55

    Max. fuse 25A

    Drawing number 20100136

    Figure 13: HU2 DPV(M)E2/4/6 DPC 20100136-A

    Art

    iclenum

    ber

    Num

    bero

    fpressure

    stages

    Fitting

    (ma

    teria

    l-

    connec

    tion

    )

    Co

    llec

    tingp

    ipe

    (ma

    teria

    l

    -connec

    tion

    )

    Pressurec

    lass

    Imax

    ins

    talla

    tion

    Pumpspee

    d

    H1[mm

    ]

    H2[mm

    ]

    H3[mm

    ]

    B1[mm

    ]

    B2[mm

    ]

    B3[mm

    ]

    L1[mm

    ]

    Mass

    [kg

    ]

    DPVME2

    HU212201D11N /2 AISI304 G 1 AISI304 G 6/4 PN10 3.00A 2750rpm 1036 90 90 255 210 240 520 65

    HU212301D11N /3 AISI304 G 1 AISI304 G 6/4 PN10 3.00A 2750rpm 1036 90 90 255 210 240 520 65

    HU212401D11N /4 AISI304 G 1 AISI304 G 6/4 PN10 3.00A 2750rpm 1036 90 90 255 210 240 520 66

    HU212501D11N /5 AISI304 G 1 AISI304 G 6/4 PN10 3.00A 2750rpm 1036 90 90 255 210 240 520 67

    HU212601D11N /6 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2790rpm 1036 90 90 255 210 240 520 68

    DPVME4

    HU214201D11N /2 AISI304 G 1 AISI304 G 6/4 PN10 3.00A 2750rpm 1036 90 90 255 210 240 520 65

    HU214301D11N /3 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2790rpm 1036 90 90 255 210 240 520 66

    HU214401D11N /4 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2790rpm 1036 90 90 255 210 240 520 66

    HU214501D11N /5 AISI304 G 1 AISI304 G 6/4 PN10 5.00A 2875rpm 1036 90 90 255 210 240 520 79

    HU214601D11N /6 AISI304 G 1 AISI304 G 6/4 PN10 6.00A 2875rpm 1036 90 90 255 210 240 520 80

    DPVME6

    HU216201D11N /2 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2790rpm 1036 90 90 255 210 240 520 66

    HU216301D11N /3 AISI304 G 1 AISI304 G 6/4 PN10 5.00A 2875rpm 1036 90 90 255 210 240 520 79

    HU216401D11N /4 AISI304 G 1 AISI304 G 6/4 PN10 6.00A 2875rpm 1036 90 90 255 210 240 520 80

    HU216501D11N /5 AISI304 G 1 AISI304 G 6/4 PN10 6.00A 2875rpm 1036 90 90 255 210 240 520 80

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    20/64

    20

    3.1.2 HU2 DPVE2/4/6 DPC DOL

    Figure 14: HU2 DPVE2/4/6 DPC 20100700

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    21/64

    21

    Table 5: General

    Table 6: Detailed

    Control DPC DOL

    Run dry protection Pressure switch

    Connection voltage 3x400V+N 50Hz

    Insolation class IP55

    Max fuse 25A

    Drawing number 20100700

    Figure 15: HU2 DPVE2/4/6 DPC 20100700

    Ar

    tic

    lenu

    mber

    Num

    bero

    fpressure

    stages

    Fitting

    (m

    ater

    ial-

    connec

    tio

    n)

    Co

    llec

    tingp

    ipe

    (ma

    terial

    -connect

    ion

    )

    Pressure

    class

    Imax

    ins

    talla

    tion

    Pumpspee

    d

    H1[mm

    ]

    H2[mm

    ]

    H3[mm

    ]

    B1[mm

    ]

    B2[mm

    ]

    B3[mm

    ]

    L1[mm

    ]

    Mass

    [kg

    ]

    DPVE2

    HU222701D11N /7 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2790rpm 1254 90 90 255 210 240 520 70

    HU222801D11N /8 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2790rpm 1254 90 90 255 210 240 520 71

    HU222902D11N /9 AISI304 G 1 AISI304 G 6/4 PN16 4.00A 2875rpm 1254 90 90 255 210 240 520 84

    HU222A02D11N /10 AISI304 G 1 AISI304 G 6/4 PN16 4.00A 2875rpm 1254 90 90 255 210 240 520 85

    HU222B02D11N /11 AISI304 G 1 AISI304 G 6/4 PN16 6.00A 2875rpm 1254 90 90 255 210 240 520 86

    DPVE4

    HU224702D11N /7 AISI304 G 1 AISI304 G 6/4 PN16 6.00A 2875rpm 1254 90 90 255 210 240 520 82

    HU224802D11N /8 AISI304 G 1 AISI304 G 6/4 PN16 7.00A 2900rpm 1254 90 90 255 210 240 520 95

    HU224902D11N /9 AISI304 G 1 AISI304 G 6/4 PN16 7.00A 2900rpm 1254 90 90 255 210 240 520 96DPVE6

    HU226601D11N /6 AISI304 G 1 AISI304 G 6/4 PN10 7.00A 2900rpm 1254 90 90 255 210 240 520 94

    HU226702D11N /7 AISI304 G 1 AISI304 G 6/4 PN16 7.00A 2900rpm 1254 90 90 255 210 240 520 95

    HU226802D11N /8 AISI304 G 1 AISI304 G 6/4 PN16 9.00A 2900rpm 1254 90 90 255 210 240 520 98

    HU226902D11N /9 AISI304 G 1 AISI304 G 6/4 PN16 9.00A 2900rpm 1254 90 90 255 210 240 520 99

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    22/64

    22

    3.1.3 HU2 DPVE10 DPC DOL

    Figure 16: HU2 DPVE10 PN10 DPC 20100746

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    23/64

    23

    Table 7: General

    Table 8: Detailed

    Control DPC DOL

    Run dry protection Pressure switch

    Connection voltage 3x400V+N 50Hz

    Insolation class IP55

    Max. fuse 25A

    Drawing number 20100746

    Figure 17: HU2 DPVE10 PN10 DPC 20100476

    A

    rtic

    lenum

    ber

    N

    um

    bero

    fpressure

    F

    itting

    (ma

    teria

    l-

    connec

    tion

    )

    C

    ollec

    tingp

    ipe

    (m

    ater

    ial

    -

    connec

    tion

    )

    P

    ressurec

    lass

    Imax

    ins

    talla

    tion

    P

    umpspee

    d

    H

    1[mm

    ]

    H

    2[mm

    ]

    H

    3[mm

    ]

    B

    1[mm

    ]

    B

    2[mm

    ]

    B

    3[mm

    ]

    L

    1[mm

    ]

    M

    ass

    [kg

    ]

    DPVE10

    HU22A201E11N /2 AISI304 G 5/4 AISI304 G 2 PN10 4.44A 2850rpm 1240 120 120 295 260 275 600 101

    HU22A301E11N /3 AISI304 G 5/4 AISI304 G 2 PN10 5.86A 2850rpm 1240 120 120 295 260 275 600 113

    HU22A401E11N /4 AISI304 G 5/4 AISI304 G 2 PN10 8.20A 2850rpm 1240 120 120 295 260 275 600 121

    HU22A501E11N /5 AISI304 G 5/4 AISI304 G 2 PN10 8.20A 2850rpm 1240 120 120 295 260 275 600 130

    HU22A602E11N /6 AISI304 G 5/4 AISI304 G 2 PN16 8.20A 2850rpm 1240 120 120 295 260 275 600 139

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    24/64

    24

    3.1.4 HU3 DPV(M)E2/4/6 DPC DOL

    Figure 18: HU3 DPV(M)E2/4/6 DPC 20100137-A

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    25/64

    25

    Table 9: General

    Table 10: Detailed

    Control DPC DOL

    Run dry protection Pressure switch

    Connection voltage 3x400V+N 50Hz

    Insolation class IP55

    Max. fuse 25A

    Drawing number 20100137

    Figure 19: HU3 DPV(M)E2/4/6 DPC 20100137-A

    Ar

    tic

    lenu

    mber

    Num

    bero

    fpressure

    Fitting

    (m

    ater

    ial-

    connec

    tio

    n)

    Co

    llec

    tingp

    ipe

    (ma

    terial

    -connect

    ion

    )

    Pressure

    class

    Imax

    ins

    talla

    tion

    Pumpspee

    d

    H1[mm

    ]

    H2[mm

    ]

    H3[mm

    ]

    B1[mm

    ]

    B2[mm

    ]

    B3[mm

    ]

    L1[mm

    ]

    Mass

    [kg

    ]

    DPVME2

    HU312201D11N /2 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2750rpm 1036 90 90 255 210 240 740 87

    HU312301D11N /3 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2750rpm 1036 90 90 255 210 240 740 88

    HU312401D11N /4 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2750rpm 1036 90 90 255 210 240 740 90

    HU312501D11N /5 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2750rpm 1036 90 90 255 210 240 740 91

    HU312601D11N /6 AISI304 G 1 AISI304 G 6/4 PN10 5.00A 2790rpm 1036 90 90 255 210 240 740 92

    DPVME4

    HU314201D11N /2 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2750rpm 1036 90 90 255 210 240 740 87

    HU314301D11N /3 AISI304 G 1 AISI304 G 6/4 PN10 5.00A 2790rpm 1036 90 90 255 210 240 740 89

    HU314401D11N /4 AISI304 G 1 AISI304 G 6/4 PN10 5.00A 2790rpm 1036 90 90 255 210 240 740 90HU314501D11N /5 AISI304 G 1 AISI304 G 6/4 PN10 7.00A 2875rpm 1036 90 90 255 210 240 740 108

    HU314601D11N /6 AISI304 G 1 AISI304 G 6/4 PN10 9.00A 2875rpm 1036 90 90 255 210 240 740 110

    DPVME6

    HU316201E11N /2 AISI304 G 1 AISI304 G 2 PN10 5.00A 2790rpm 1036 90 90 260 210 245 740 90

    HU316301E11N /3 AISI304 G 1 AISI304 G 2 PN10 7.00A 2875rpm 1036 90 90 260 210 245 740 109

    HU316401E11N /4 AISI304 G 1 AISI304 G 2 PN10 9.00A 2875rpm 1036 90 90 260 210 245 740 110

    HU316501E11N /5 AISI304 G 1 AISI304 G 2 PN10 9.00A 2875rpm 1036 90 90 260 210 245 740 111

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    26/64

    26

    3.1.5 HU3 DPVE2/4/6 DPC DOL

    Figure 20: HU3 DPVE2/4/6 DPC 20100701

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    27/64

    27

    Table 11: General

    Table 12: Detailed

    Control DPC DOL

    Run dry protection Pressure switch

    Connection voltage 3x400V+N 50Hz

    Insolation class IP55

    Max. fuse 25A

    Drawing number 20100701

    Figure 21: HU3 DPVE2/4/6 DPC 20100701

    Ar

    tic

    lenu

    mber

    Num

    bero

    fpressure

    stages

    Fitting

    (m

    ater

    ial-

    connec

    tio

    n)

    Co

    llec

    tingp

    ipe

    (ma

    terial

    -connect

    ion

    )

    Pressure

    class

    Imax

    ins

    talla

    tion

    Pumpspee

    d

    H1[mm

    ]

    H2[mm

    ]

    H3[mm

    ]

    B1[mm

    ]

    B2[mm

    ]

    B3[mm

    ]

    L1[mm

    ]

    Mass

    [kg

    ]

    DPVE2

    HU322701D11N /7 AISI304 G 1 AISI304 G 6/4 PN10 5.00A 2790rpm 1254 90 90 255 210 240 740 96

    HU322801D11N /8 AISI304 G 1 AISI304 G 6/4 PN10 5.00A 2790rpm 1254 90 90 255 210 240 740 97

    HU322902D11N /9 AISI304 G 1 AISI304 G 6/4 PN16 6.00A 2875rpm 1254 90 90 255 210 240 740 116

    HU322A02D11N /10 AISI304 G 1 AISI304 G 6/4 PN16 6.00A 2875rpm 1254 90 90 255 210 240 740 118

    HU322B02D11N /11 AISI304 G 1 AISI304 G 6/4 PN16 8.00A 2875rpm 1254 90 90 255 210 240 740 119

    DPVE4

    HU324702D11N /7 AISI304 G 1 AISI304 G 6/4 PN16 8.00A 2875rpm 1254 90 90 255 210 240 740 114

    HU324802D11N /8 AISI304 G 1 AISI304 G 6/4 PN16 10.00A 2900rpm 1254 90 90 255 210 240 740 133

    HU324902D11N /9 AISI304 G 1 AISI304 G 6/4 PN16 10.00A 2900rpm 1254 90 90 255 210 240 740 134DPVE6

    HU326601E11N /6 AISI304 G 1 AISI304 G 2 PN10 10.00A 2900rpm 1254 90 90 260 210 245 740 132

    HU326702E11N /7 AISI304 G 1 AISI304 G 2 PN16 10.00A 2900rpm 1254 90 90 260 210 245 740 134

    HU326802E11N /8 AISI304 G 1 AISI304 G 2 PN16 14.00A 2900rpm 1254 90 90 260 210 245 740 138

    HU326902E11N /9 AISI304 G 1 AISI304 G 2 PN16 14.00A 2900rpm 1254 90 90 260 210 245 740 140

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    28/64

    28

    3.1.6 HU3 DPVE10 DPC DOL

    Figure 22: HU3 DPVE10 PN10 DPC 20100747

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    29/64

    29

    Table 13: General

    Table 14: Detailed

    Control DPC DOL

    Run dry protection Pressure switch

    Connection voltage 3x400V+N 50Hz

    Insolation class IP55

    Max. fuse 25A

    Drawing number 20100747

    Figure 23: HU3 DPVE10 PN10 DPC 20100747

    A

    rtic

    lenum

    ber

    N

    um

    bero

    fpressure

    F

    itting

    (ma

    teria

    l-

    connec

    tion

    )

    C

    ollec

    tingp

    ipe

    (m

    ater

    ial

    -

    connec

    tion

    )

    P

    ressurec

    lass

    Imax

    ins

    talla

    tion

    P

    umpspee

    d

    H

    1[mm

    ]

    H

    2[mm

    ]

    H

    3[mm

    ]

    B

    1[mm

    ]

    B

    2[mm

    ]

    B

    3[mm

    ]

    L

    1[mm

    ]

    M

    ass

    [kg

    ]

    DPVE10

    HU32A201E11N /2 AISI304 G 5/4 AISI304 G 2 PN10 1.72A 2850rpm 1240 120 120 295 260 275 860 136

    HU32A301E11N /3 AISI304 G 5/4 AISI304 G 2 PN10 2.43A 2850rpm 1240 120 120 295 260 275 860 153

    HU32A401E11N /4 AISI304 G 5/4 AISI304 G 2 PN10 3.60A 2850rpm 1240 120 120 295 260 275 860 166

    HU32A501E11N /5 AISI304 G 5/4 AISI304 G 2 PN10 4.80A 2850rpm 1240 120 120 295 260 275 860 179

    HU32A602E11N /6 AISI304 G 5/4 AISI304 G 2 PN16 15.4A 2850rpm 1240 120 120 295 260 275 860 191

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    30/64

    30

    3.1.7 Specification text

    All DP-Pumps booster-set comply with the NEN1006

    (NL) standard and have been constructed as

    described in the water worksheets (NL)

    Consisting of:

    two or three DPV(M)E vertical multi-stagecentrifugal pumps with integrated non-return

    valve (G1or G5/4) of which all parts that come

    into contact with the medium have been made of

    AISI304

    four or six AISI304 ball valves (G1 or G5/4) AISI304 collecting pipes (G6/4 or G2) under pressure protection set consisting of a

    pressure switch (20 kPa ON, 110 kPa reset),

    pressure gauge and a drain valve

    discharge pressure control set consisting of apressure transmitter (4-20 mA/0-1000kPa or 4-20mA/0-2500kPa), pressure gauge, 8 litres

    membrane vessel and a drain valve.

    The booster-set is equipped with a switch box with

    the DP-Control system. The switch-box is by default

    equipped with the following fault options:

    tensionless signal urgent (red LED) tensionless signal not urgent (orange LED)

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    31/64

    31

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    32/64

    32

    3.2 Dimensions and weights HU HR installation (incl. WSD)

    3.2.1 HU2 DPV(M)E2/4/6 HR

    Figure 24: HU2 DPV(M)E2/4/6 DPC-HR with 100 l membrane vessel 20100140-B

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    33/64

    33

    Table 15: General

    Table 16: Detailed

    Control DPC DOL HR

    Run dry protection Pressure switch

    Connection voltage 3x400V+N 50Hz

    Insolation class IP55

    Max. fuse 25A

    Drawing number 20100140

    Figure 25: HU2 DPV(M)E2/4/6 DPC-HR

    with 100 l membrane vessel 20100140-B

    Ar

    tic

    lenum

    ber

    Num

    bero

    fpressure

    Fitting

    (ma

    teria

    l-

    connec

    tion

    )

    Co

    llec

    ting

    pipe

    (ma

    teria

    l

    -connection

    )

    Pressurec

    lass

    Imax

    insta

    lla

    tion

    Pumpspe

    ed

    H1[mm

    ]

    H2[mm

    ]

    H3[mm

    ]

    B1[mm

    ]

    B2[mm

    ]

    B3[mm

    ]

    L1[mm

    ]

    Mass

    [kg]

    DPVME2

    HU212201D21N /2 AISI304 G 1 AISI304 G 6/4 PN10 3.00A 2750rpm 1036 90 90 255 210 240 520 85

    HU212301D21N /3 AISI304 G 1 AISI304 G 6/4 PN10 3.00A 2750rpm 1036 90 90 255 210 240 520 85

    HU212401D21N /4 AISI304 G 1 AISI304 G 6/4 PN10 3.00A 2750rpm 1036 90 90 255 210 240 520 86

    HU212501D21N /5 AISI304 G 1 AISI304 G 6/4 PN10 3.00A 2750rpm 1036 90 90 255 210 240 520 87

    HU212601D21N /6 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2790rpm 1036 90 90 255 210 240 520 88

    DPVME4

    HU214201D21N /2 AISI304 G 1 AISI304 G 6/4 PN10 3.00A 2750rpm 1036 90 90 255 210 240 520 85

    HU214301D21N /3 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2790rpm 1036 90 90 255 210 240 520 86

    HU214401D21N /4 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2790rpm 1036 90 90 255 210 240 520 86

    HU214501D21N /5 AISI304 G 1 AISI304 G 6/4 PN10 5.00A 2875rpm 1036 90 90 255 210 240 520 99

    HU214601D21N /6 AISI304 G 1 AISI304 G 6/4 PN10 6.00A 2875rpm 1036 90 90 255 210 240 520 100

    DPVME6

    HU216201D21N /2 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2790rpm 1036 90 90 255 210 240 520 86

    HU216301D21N /3 AISI304 G 1 AISI304 G 6/4 PN10 5.00A 2875rpm 1036 90 90 255 210 240 520 99

    HU216401D21N /4 AISI304 G 1 AISI304 G 6/4 PN10 6.00A 2875rpm 1036 90 90 255 210 240 520 100

    HU216501D21N /5 AISI304 G 1 AISI304 G 6/4 PN10 6.00A 2875rpm 1036 90 90 255 210 240 520 100

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    34/64

    34

    3.2.2 HU2 DPVE2/4/6 HR

    Figure 26: HU2 DPVE2/4/6 DPC-HR with 100 l membrane vessel 20100704-A

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    35/64

    35

    Table 17: General

    Table 18: Detailed

    Control DPC DOL HR

    Run dry protection Pressure switch

    Connection voltage 3x400V+N 50Hz

    Insolation IP55

    Max. fuse 25A

    Drawing number 20100704

    Figure 27: HU2 DPVE2/4/6 DPC-HR with

    100 l membrane vessel 20100704-A

    Ar

    tic

    lenum

    ber

    Num

    bero

    fpressu

    re

    Fitting

    (ma

    ter

    ial-

    connec

    tion

    )

    Co

    llec

    tingp

    ipe

    (ma

    ter

    ial

    -connec

    tion

    )

    Pressurec

    lass

    Imax

    ins

    talla

    tion

    Pumpspee

    d

    H1[mm

    ]

    H2[mm

    ]

    H3[mm

    ]

    B1[mm

    ]

    B2[mm

    ]

    B3[mm

    ]

    L1[mm

    ]

    Mass

    [kg

    ]

    DPVE2

    HU222701D21N /7 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2790rpm 1254 90 90 255 210 240 520 90

    HU222801D21N /8 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2790rpm 1254 90 90 255 210 240 520 91

    DPVE6

    HU226601D21N /6 AISI304 G 1 AISI304 G 6/4 PN10 7.00A 2900rpm 1254 90 90 255 210 240 520 114

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    36/64

    36

    3.2.3 HU2 DPVE10 HR

    Figure 28: HU2 DPVE10 PN10 DPC HR with 200 l membrane vessel 20100748-B

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    37/64

    37

    Table 19: General

    Table 20: Detailed

    Control DPC DOL HR

    Run dry protection Pressure Switch

    Connection voltage 3x400V+N 50Hz

    Insolation class IP55

    Max. fuse 25A

    Drawing number 20100748

    Figure 29: HU2 DPVE10 PN10 DPC HR 20100748-B

    Ar

    tic

    lenum

    ber

    Num

    bero

    fpressure

    Fittin

    g(ma

    ter

    ial-

    conn

    ec

    tion

    )

    Co

    lle

    ctingp

    ipe

    (mater

    ial

    -con

    nec

    tion

    )

    Pressurec

    lass

    Imax

    ins

    talla

    tion

    Pumpspee

    d

    H1[m

    m]

    H2[m

    m]

    H3[m

    m]

    B1[m

    m]

    B2[m

    m]

    B3[m

    m]

    L1[m

    m]

    Mass

    [kg

    ]

    DPVE10

    HU22A201E21N /2 AISI304 G 5/4 AISI304 G 2 PN10 1.72A 2850rpm 1240 120 120 295 260 275 600 140

    HU22A301E21N /3 AISI304 G 5/4 AISI304 G 2 PN10 2.43A 2850rpm 1240 120 120 295 260 275 600 151

    HU22A401E21N /4 AISI304 G 5/4 AISI304 G 2 PN10 3.60A 2850rpm 1240 120 120 295 260 275 600 160

    HU22A501E21N /5 AISI304 G 5/4 AISI304 G 2 PN10 4.80A 2850rpm 1240 120 120 295 260 275 600 168

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    38/64

    38

    3.2.4 HU3 DPV(M)E2/4/6HR

    Figure 30: HU3 DPV(M)E2/4/6 DPC-HR with 100 l membrane vessel 20100141-B

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    39/64

    39

    Table 21: General

    Table 22: Detailed

    Control DPC DOL HR

    Run dry protection Pressure switch

    Connection voltage 3x400V+N 50Hz

    Insolation class IP55

    Max. fuse 25A

    Drawing number 20100141

    Figure 31: HU3 DPV(M)E2/4/6 DPC-HR

    with 100 l membrane vessel 20100141-B

    Ar

    tic

    lenum

    ber

    Nu

    mbero

    fpressure

    Fitting

    (ma

    teria

    l-

    co

    nnec

    tion

    )

    Co

    llec

    tingp

    ipe

    (m

    ateria

    l

    -c

    onnec

    tion

    )

    Pressurec

    lass

    Im

    ax

    ins

    talla

    tion

    Pu

    mpspee

    d

    H1

    [mm

    ]

    H2

    [mm

    ]

    H3

    [mm

    ]

    B1

    [mm

    ]

    B2

    [mm

    ]

    B3

    [mm

    ]

    L1

    [mm

    ]

    Ma

    ss

    [kg

    ]

    DPVME2

    HU312201D21N /2 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2750rpm 1036 90 90 255 210 240 740 107

    HU312301D21N /3 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2750rpm 1036 90 90 255 210 240 740 108

    HU312401D21N /4 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2750rpm 1036 90 90 255 210 240 740 110

    HU312501D21N /5 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2750rpm 1036 90 90 255 210 240 740 111

    HU312601D21N /6 AISI304 G 1 AISI304 G 6/4 PN10 5.00A 2790rpm 1036 90 90 255 210 240 740 112

    DPVME4

    HU314201D21N /2 AISI304 G 1 AISI304 G 6/4 PN10 4.00A 2750rpm 1036 90 90 255 210 240 740 107

    HU314301D21N /3 AISI304 G 1 AISI304 G 6/4 PN10 5.00A 2790rpm 1036 90 90 255 210 240 740 109

    HU314401D21N /4 AISI304 G 1 AISI304 G 6/4 PN10 5.00A 2790rpm 1036 90 90 255 210 240 740 110

    HU314501D21N /5 AISI304 G 1 AISI304 G 6/4 PN10 7.00A 2875rpm 1036 90 90 255 210 240 740 128

    HU314601D21N /6 AISI304 G 1 AISI304 G 6/4 PN10 9.00A 2875rpm 1036 90 90 255 210 240 740 130DPVME6

    HU316201E21N /2 AISI304 G 1 AISI304 G 2 PN10 5.00A 2790rpm 1036 90 90 260 210 245 740 115

    HU316301E21N /3 AISI304 G 1 AISI304 G 2 PN10 7.00A 2875rpm 1036 90 90 260 210 245 740 134

    HU316401E21N /4 AISI304 G 1 AISI304 G 2 PN10 9.00A 2875rpm 1036 90 90 260 210 245 740 135

    HU316501E21N /5 AISI304 G 1 AISI304 G 2 PN10 9.00A 2875rpm 1036 90 90 260 210 245 740 136

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    40/64

    40

    3.2.5 HU3 DPVE2/4/6 HR

    Figure 32: HU3 DPVE2/4/6 DPC-HR with 100 l membrane vessel 20100705-A

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    41/64

    41

    Table 23: General

    Table 24: Detailed

    Control DPC DOL HR

    Run dry protection Pressure switch

    Connection voltage 3x400V+N 50Hz

    Insolation class IP55

    Max. fuse 25A

    Drawing number 20100705

    Figure 33: HU3 DPVE2/4/6 DPC-HR with

    100 l membrane vessel 20100705-A

    Ar

    tic

    len

    um

    ber

    Num

    ber

    ofpressure

    Fitting

    (m

    ateria

    l-

    connect

    ion

    )

    Co

    llec

    tin

    gp

    ipe

    (ma

    teria

    l

    -connec

    tion

    )

    Pressure

    class

    Imax

    ins

    talla

    tion

    Pumpsp

    ee

    d

    H1[mm]

    H2[mm]

    H3[mm]

    B1[mm]

    B2[mm]

    B3[mm]

    L1[mm]

    Mass

    [kg

    ]

    DPVE2

    HU322701D21N /7 AISI304 G 1 AISI304 G 6/4 PN10 5.00A 2790rpm 1254 90 90 255 210 240 740 115

    HU322801D21N /8 AISI304 G 1 AISI304 G 6/4 PN10 5.00A 2790rpm 1254 90 90 255 210 240 740 116

    DPVE6

    HU326601E21N /6 AISI304 G 1 AISI304 G 2 PN10 10.00A 2900rpm 1254 90 90 260 210 245 740 157

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    42/64

    42

    3.2.6 HU3 DPVE10 HR

    Figure 34: HU3 DPVE10 PN10 DPC HR with 200 l membrane vessel 20100749-A

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    43/64

    43

    Table 25: General

    Table 26: Detailed

    Control DPC DOL HR

    Run dry protection Pressure switch

    Connection voltage 3x400V+N 50Hz

    Insolation class IP55

    Max. fuse 25A

    Drawing number 20100749

    Figure 35: HU3 DPVE10 PN10 DPC HR

    with 200 l membrane vessel 20100749-A

    A

    rticlenum

    ber

    N

    um

    bero

    fpressure

    F

    itting

    (ma

    ter

    ial-

    c

    onnec

    tion

    )

    C

    ollec

    tingp

    ipe

    (ma

    teria

    l

    -

    connec

    tion

    )

    P

    ressurec

    lass

    I

    max

    ins

    talla

    tion

    P

    umpspee

    d

    H

    1[mm

    ]

    H

    2[mm

    ]

    H

    3[mm

    ]

    B

    1[mm

    ]

    B

    2[mm

    ]

    B

    3[mm

    ]

    L

    1[mm

    ]

    M

    ass

    [kg

    ]

    DPVE10

    HU32A201E21N /2 AISI304 G 5/4 AISI304 G 2 PN10 1.72A 2850rpm 1240 120 120 295 260 275 860 179

    HU32A301E21N /3 AISI304 G 5/4 AISI304 G 2 PN10 2.43A 2850rpm 1240 120 120 295 260 275 860 196

    HU32A401E21N /4 AISI304 G 5/4 AISI304 G 2 PN10 3.60A 2850rpm 1240 120 120 295 260 275 860 209

    HU32A501E21N /5 AISI304 G 5/4 AISI304 G 2 PN10 4.80A 2850rpm 1240 120 120 295 260 275 860 221

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    44/64

    44

    3.2.7 Specification text

    All DP-Pumps booster-set comply with the NEN1006

    (NL) standard and have been constructed as

    described in the water worksheets (NL)

    Consisting of:

    two or three DPV(M)E vertical multi-stagecentrifugal pumps with integrated non-return

    valve (G1or G5/4) of which all parts that come

    into contact with the medium have been made of

    AISI304

    four or six AISI304 ball valves (G1 or G5/4) AISI304 collecting pipes (G6/4 or G2) under pressure protection set consisting of a

    pressure switch (20 kPa ON, 110 kPa reset),

    pressure gauge and a drain valve

    discharge pressure control set consisting of apressure transmitter (4-20 mA/0-1000kPa),pressure gauge and a drain valve.

    AISI304 tank connection pipe set with WSDsensor and a membrane vessel (mechanical

    minimum runtime) with a volume of 100 litres or

    200 litres

    The booster-set is equipped with a switch box with

    the DP-Control system. The switch-box is by default

    equipped with the following fault options:

    tensionless signal urgent (red LED)

    tensionless signal not urgent (orange LED)

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    45/64

    45

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    46/64

    46

    3.3 Dimensions and weights HU MCMF (FR)

    3.3.1 HU2 DPV(M)E2/4/6 MCMF

    Figure 36: HU2 DPV(M)E2/4/6 MCMF 20100144-A

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    47/64

    47

    Table 27: General

    Table 28: Detailed

    Control MCMF 60Hz

    Run dry protection Pressure switch

    Connection voltage 3x400V+N 50Hz/60Hz

    Insolation class IP55

    Max. fuse 25A

    Drawing number 20100144

    Figure 37: HU2 DPV(M)E2/4/6 MCMF 20100144-A

    Ar

    tic

    lenum

    ber

    Num

    bero

    fpressure

    Fitting

    (ma

    teria

    l-

    connec

    tion

    )

    Co

    llec

    tingp

    ipe

    (ma

    ter

    ial

    -connec

    tion

    )

    Pressurec

    lass

    Imax

    ins

    talla

    tion

    Pumpspee

    d

    H1[mm

    ]

    H2[mm

    ]

    H3[mm

    ]

    B1[mm

    ]

    B2[mm

    ]

    B3[mm

    ]

    L1[mm

    ]

    Mass

    [kg

    ]

    DPVME2

    HU212201D64N /2 AISI304 G 1 AISI304 G 6/4 PN10 13.00A 3300rpm 1254 90 90 255 210 240 520 76

    HU212301D64N /3 AISI304 G 1 AISI304 G 6/4 PN10 13.00A 3300rpm 1254 90 90 255 210 240 520 77

    HU212401D64N /4 AISI304 G 1 AISI304 G 6/4 PN10 13.00A 3345rpm 1254 90 90 255 210 240 520 78

    HU212501D64N /5 AISI304 G 1 AISI304 G 6/4 PN10 13.00A 3450rpm 1254 90 90 255 210 240 520 90

    HU212602D64N /6 AISI304 G 1 AISI304 G 6/4 PN16 13.00A 3450rpm 1254 90 90 255 210 240 520 91

    DPVME4

    HU214201D64N /2 AISI304 G 1 AISI304 G 6/4 PN10 13.00A 3345rpm 1254 90 90 255 210 240 520 76

    HU214301D64N /3 AISI304 G 1 AISI304 G 6/4 PN10 13.00A 3450rpm 1254 90 90 255 210 240 520 89

    HU214401D64N /4 AISI304 G 1 AISI304 G 6/4 PN10 13.00A 3450rpm 1254 90 90 255 210 240 520 89

    DPVME6

    HU216201D64N /2 AISI304 G 1 AISI304 G 6/4 PN10 13.00A 3450rpm 1254 90 90 255 210 240 520 89

    HU216301D64N /3 AISI304 G 1 AISI304 G 6/4 PN10 13.00A 3450rpm 1254 90 90 255 210 240 520 90

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    48/64

    48

    3.3.2 HU2 DPVE2/4/6 MCMF

    Figure 38: HU2 DPVE2/4/6 MCMF 20100756

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    49/64

    49

    Table 29: General

    Table 30: Detailwaarden

    Control MCMF 60Hz

    Run dry protection Pressure switch

    Connection voltage 3x400V+N 50Hz/60Hz

    Insolation class IP55

    Max. fuse 25A

    Drawing number 20100756

    Figure 39: HU2 DPVE2/4/6 MCMF 20100756

    Ar

    tic

    lenum

    ber

    Num

    bero

    fpressure

    Fitting

    (ma

    teria

    l-

    connec

    tion

    )

    Co

    llec

    tingp

    ipe

    (ma

    ter

    ial

    -connec

    tion

    )

    Pressurec

    lass

    Imax

    ins

    talla

    tion

    Pumpspee

    d

    H1[mm

    ]

    H2[mm

    ]

    H3[mm

    ]

    B1[mm

    ]

    B2[mm

    ]

    B3[mm

    ]

    L1[mm

    ]

    Mass

    [kg

    ]

    DPVE2

    HU222702D64N /7 AISI304 G 1 AISI304 G 6/4 PN16 13.00A 3450rpm 1254 90 90 255 210 240 520 95

    DPVE4

    HU224502D64N /5 AISI304 G 1 AISI304 G 6/4 PN16 11.00A 3480rpm 1254 90 90 255 210 240 520 106

    HU224602D64N /6 AISI304 G 1 AISI304 G 6/4 PN16 11.00A 3480rpm 1254 90 90 255 210 240 520 107

    DPVE6

    HU226401D64N /4 AISI304 G 1 AISI304 G 6/4 PN10 11.00A 3480rpm 1254 90 90 255 210 240 520 106

    HU226502D64N /5 AISI304 G 1 AISI304 G 6/4 PN16 15.00A 3480rpm 1254 90 90 255 210 240 520 109

    HU226602D64N /6 AISI304 G 1 AISI304 G 6/4 PN16 15.00A 3480rpm 1254 90 90 255 210 240 520 111

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    50/64

    50

    3.3.3 HU2 DPVE10 MCMF

    Figure 40: HU2 DPVE10 PN10 MCMF 20100750

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    51/64

    51

    Table 31: General

    Table 32: Detailed

    Control MCMF 50Hz

    Run dry protection Pressure switch

    Connection voltage 3x400V+N 50Hz

    Insolation class IP55

    Max. fuse 25A

    Drawing number 20100750

    Figure 41: HU2 DPVE10 PN10 MCMF 20100750

    Ar

    tic

    lenum

    ber

    Num

    bero

    fpressure

    Fitting

    (ma

    teria

    l-

    connec

    tion

    )

    Co

    llec

    tingp

    ipe

    (ma

    ter

    ial

    -connec

    tion

    )

    Pressurec

    lass

    Imax

    ins

    talla

    tion

    [A]

    Pumpspee

    d

    H1[mm

    ]

    H2[mm

    ]

    H3[mm

    ]

    B1[mm

    ]

    B2[mm

    ]

    B3[mm

    ]

    L1[mm

    ]

    Mass

    [kg

    ]

    DPVE10

    HU22A201E64N /2 AISI304 G 5/4 AISI304 G 2 PN10 6.73 2850rpm 1240 120 120 295 260 275 600 117

    HU22A301E64N /3 AISI304 G 5/4 AISI304 G 2 PN10 9.10 2850rpm 1240 120 120 295 260 275 600 130

    HU22A401E64N /4 AISI304 G 5/4 AISI304 G 2 PN10 13.00 2850rpm 1240 120 120 295 260 275 600 139

    HU22A501E64N /5 AISI304 G 5/4 AISI304 G 2 PN10 17.00 2850rpm 1240 120 120 295 260 275 600 147

    HU22A602E64N /6 AISI304 G 5/4 AISI304 G 2 PN16 17.00 2850rpm 1240 120 120 295 260 275 600 156

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    52/64

    52

    3.3.4 HU3 DPV(M)E2/4/6 MCMF

    Figure 42: HU3 DPV(M)E2/4/6 MCMF 20100145-A

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    53/64

    53

    Table 33: General

    Table 34: Detailed

    Control MCMF 60Hz

    Run dry protection Pressure switch

    Connection voltage 3x400V+N 50Hz/60Hz

    Insolation class IP55

    Max. fuse 25A

    Drawing number 20100145

    Figure 43: HU3 DPV(M)E2/4/6 MCMF 20100145-A

    Art

    iclenum

    ber

    Num

    bero

    fpressure

    Fitting

    (ma

    ter

    ial-

    connec

    tion

    )

    Co

    llec

    tingp

    ipe

    (ma

    teria

    l

    -connec

    tion

    )

    Pressurec

    lass

    Imax

    ins

    talla

    tion

    Pumpspee

    d

    H1[mm

    ]

    H2[mm

    ]

    H3[mm

    ]

    B1[mm

    ]

    B2[mm

    ]

    B3[mm

    ]

    L1[mm

    ]

    Mass

    [kg

    ]

    DPVME2

    HU312201D64N /2 AISI304 G 1 AISI304 G 6/4 PN10 13.00A 3300rpm 1254 90 90 255 210 240 740 100

    HU312301D64N /3 AISI304 G 1 AISI304 G 6/4 PN10 13.00A 3300rpm 1254 90 90 255 210 240 740 101

    HU312401D64N /4 AISI304 G 1 AISI304 G 6/4 PN10 13.00A 3345rpm 1254 90 90 255 210 240 740 102

    HU312501D64N /5 AISI304 G 1 AISI304 G 6/4 PN10 13.00A 3450rpm 1254 90 90 255 210 240 740 121

    HU312602D64N /6 AISI304 G 1 AISI304 G 6/4 PN16 13.00A 3450rpm 1254 90 90 255 210 240 740 122DPVME4

    HU314201D64N /2 AISI304 G 1 AISI304 G 6/4 PN10 13.00A 3345rpm 1254 90 90 255 210 240 740 100

    HU314301D64N /3 AISI304 G 1 AISI304 G 6/4 PN10 13.00A 3450rpm 1254 90 90 255 210 240 740 119

    HU314401D64N /4 AISI304 G 1 AISI304 G 6/4 PN10 13.00A 3450rpm 1254 90 90 255 210 240 740 120

    DPVME6

    HU316201E64N /2 AISI304 G 1 AISI304 G 2 PN10 13.00A 3450rpm 1254 90 90 260 210 245 740 120

    HU316301E64N /3 AISI304 G 1 AISI304 G 2 PN10 13.00A 3450rpm 1254 90 90 260 210 245 740 122

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    54/64

    54

    3.3.5 HU3 DPVE2/4/6 MCMF

    Figure 44: HU3 DPVE2/4/6 MCMF 20100757

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    55/64

    55

    Table 35: General

    Table 36: Detailed

    Control MCMF 60Hz

    Run dry protection DRUKSCHAKELAAR

    Connection voltage 3x400V+N 50Hz/60Hz

    Insolation class IP55

    Max. fuse 25A

    Drawing number 20100757

    Figure 45: HU3 DPV(M)E2/4/6 MCMF 20100757

    Art

    iclenum

    ber

    Num

    bero

    fpressure

    Fitting

    (ma

    ter

    ial-

    connec

    tion

    )

    Co

    llec

    tingp

    ipe

    (ma

    teria

    l

    -connec

    tion

    )

    Pressurec

    lass

    Imax

    ins

    talla

    tion

    Pumpspee

    d

    H1[mm

    ]

    H2[mm

    ]

    H3[mm

    ]

    B1[mm

    ]

    B2[mm

    ]

    B3[mm

    ]

    L1[mm

    ]

    Mass

    [kg

    ]

    DPVE2

    HU322702D64N /7 AISI304 G 1 AISI304 G 6/4 PN16 13.00A 3450rpm 1254 90 90 255 210 240 740 128

    DPVE4

    HU324502D64N /5 AISI304 G 1 AISI304 G 6/4 PN16 11.00A 3480rpm 1254 90 90 255 210 240 740 145HU324602D64N /6 AISI304 G 1 AISI304 G 6/4 PN16 11.00A 3480rpm 1254 90 90 255 210 240 740 147

    DPVE6

    HU326401E64N /4 AISI304 G 1 AISI304 G 2 PN10 11.00A 3480rpm 1254 90 90 260 210 245 740 146

    HU326502E64N /5 AISI304 G 1 AISI304 G 2 PN16 15.00A 3480rpm 1254 90 90 260 210 245 740 151

    HU326602E64N /6 AISI304 G 1 AISI304 G 2 PN16 15.00A 3480rpm 1254 90 90 260 210 245 740 152

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    56/64

    56

    3.3.6 HU3 DPVE10 MCMF

    Figure 46: HU3 DPVE10 PN10 MCMF 20100751

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    57/64

    57

    Table 37: General

    Table 38: Detailed

    Control MCMF 50Hz

    Run dry protection Pressure switch

    Connection voltage 3x400V+N 50Hz

    Insulation class IP55

    Max. fuse 25A

    Drawing number 20100751

    Figure 47: HU3 DPVE10 PN10 MCMF 20100751

    Ar

    tic

    lenum

    ber

    Num

    bero

    fpressure

    Fitting

    (ma

    teria

    l-

    connec

    tion

    )

    Co

    llec

    tingp

    ipe

    (ma

    ter

    ial

    -connec

    tion

    )

    Pressurec

    lass

    Imax

    ins

    talla

    tion

    [A]

    Pumpspee

    d

    H1[mm

    ]

    H2[mm

    ]

    H3[mm

    ]

    B1[mm

    ]

    B2[mm

    ]

    B3[mm

    ]

    L1[mm

    ]

    Mass

    [kg

    ]

    DPVE10

    HU32A201E64N /2 AISI304 G 5/4 AISI304 G 2 PN10 9.60 2850rpm 1240 120 120 295 260 275 860 150

    HU32A301E64N /3 AISI304 G 5/4 AISI304 G 2 PN10 13.15 2850rpm 1240 120 120 295 260 275 860 170

    HU32A401E64N /4 AISI304 G 5/4 AISI304 G 2 PN10 19.00 2850rpm 1240 120 120 295 260 275 860 183

    HU32A501E64N /5 AISI304 G 5/4 AISI304 G 2 PN10 25.00 2850rpm 1240 120 120 295 260 275 860 195

    HU32A602E64N /6 AISI304 G 5/4 AISI304 G 2 PN16 25.00 2850rpm 1240 120 120 295 260 275 860 208

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    58/64

    58

    3.3.7 Specification text

    All DP-Pumps booster-set comply with the NEN1006

    (NL) standard and have been constructed as

    described in the water worksheets (NL)

    Consisting of:

    two or three DPV(M)E vertical multi-stagecentrifugal pumps with integrated non-return

    valve (G1or G5/4) of which all parts that come

    into contact with the medium have been made of

    AISI304

    four or six AISI304 ball valves (G1 or G5/4) AISI304 collecting pipes (G6/4 or G2) under pressure protection set consisting of a

    pressure switch (20 kPa ON, 110 kPa reset),

    pressure gauge and a drain valve

    discharge pressure control set consisting of apressure transmitter (4-20 mA/0-1000kPa or 4-20mA/0-2500kPa), 8 litres membrane vessel

    and a drain valve.

    The booster-set is equipped with a switch box with

    the Megacontrol system. Each pump is equipped with

    a frequency inverter. The switch-box is by default

    equipped with the following fault options:

    tensionless signal urgent (red LED) tensionless signal not urgent (orange LED)

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    59/64

    59

    4 Accessories

    4.1 Accessories HU 2/3 DPV(M)E

    ATTENTION

    OV10020317 or OV10020318 are incompatible with OV10020416 and OV10020417.

    Ar t. number Opt ion

    OV10020317 Switch box wall mounting HU 21

    OV10020318 Switch box wall mounting HU 31

    OV10020416 Supply voltage 1*230 V HU 2

    OV10020417 Supply voltage 1*230 V HU 3

    OV10020608 Contact in switch box instead of a pressure switch as run-dry protection2

    OV10022553 1 water flow detector for the switch vessel (WSD)

    OV10022554 1 room temperature sensor PT1000 and WSD

    OV10022801 Extra costs for finishing HU2/3 DPV(M)E DPC DP English

    OV10022556 Level control by means of electrode pins

    3

    OV10022555 Level control by means of level control excluding pressure transmitter4

    OV10023000 Test report plus parameter list

    CEHU002201 Certificate booster 2.2 DP Pumps EN

    CEHU002202 Certificate booster 2.2 DP Pumps NL

    CEHU002203 Certificate booster 2.2 Duijvelaar Pompen EN

    CEHU002204 Certificate booster 2.2 Duijvelaar Pompen NL

    CEHU003101 Certificate booster 3.1 DP Pumps EN

    CEHU003102 Certificate booster 3.1 DP Pumps NL

    CEHU003103 Certificate booster 3.1 Duijvelaar Pompen EN

    CEHU003104 Certificate booster 3.1 Duijvelaar Pompen NL

    CEHU003201 Certificate booster 3.2 DP Pumps and customer EN

    CEHU003202 Certificate booster 3.2 DP Pumps and customer NL

    CEHU003203 Certificate booster 3.2 Duijvelaar Pompen and customer EN

    CEHU003204 Certificate booster 3.2 Duijvelaar Pompen and customer NL

    1. Including wall mounting brackets, cable length 5 m.

    2. A device with a switch contact that trips at interruption of the water supply to the installation is to be connected to the ter-

    minal strip (e.g. a float switch or a pressure switch)

    3. Only possible for units with DPC control.

    4. Only possible for units with MCMF control with max. 2 pumps!

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    60/64

    60

    4.1.1 Mounting sets

    Figure 48: Mounting set

    Table 39: HU mounting set

    The mounting set consists of the following

    components:

    Table 40: Components of mounting set

    4.1.2 Pressure reduc ing valves

    Ar ticle num ber Moun ting set Hydro-unit

    71100148 G 6/4 >G 5/4 (35 mm)

    71100149 G 6/4 (42 mm)

    71100150 G 2 (54 mm)

    71100151 G 2 >G 6/4 (42 mm)

    71100153 G 2 >NW65 (flange)

    71100180 G 6/4 >G 5/4 BI

    71100181 G 6/4 BI

    71100182 G 2 BI71100183 G 2 >G 6/4 BI

    Item Part

    1 hexagon cap

    2 (reducing) socket

    3 expansion joint

    4 3-part coupling Bi x Cap1

    1. Set 71100153 ends with a flange instead of a 3-part

    coupling

    5 Silent blocks

    Figure 49: Pressure reducing valve (DO6 ..) 3242/24072008

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    61/64

    61

    Table 41: Data pressure reducing valves

    Figure 50: Pressure reducing valve

    (73220023) 3243/24072008

    Article

    number

    Connection Mating

    dimensions

    Dimensions Type Bore Pressure

    class/

    range

    Specific

    materials

    Model

    73220016 BU G 1/2 L =140 mm 1.5-6 bar D06F DN15 PN16 MS ~

    73220017 BU G 1/2 L =140 mm 0.5-2 bar D06FN DN15 PN16 MS ~

    73220019 CAP 22 mm L =160 mm 1.5-12 bar D06FH DN20 PN25 MS ~

    73220020 CAP 22 mm L =160 mm 1.5-6 bar D06F DN20 PN16 MS ~

    73220022 BU G 3/4 L =160 mm 1.5-6 bar D06F DN20 PN16 MS ~

    73220023 BU (BI) 3/4 (1/2) L =65 mm 1.5-5 bar DN15 PN15 MS

    73220027 CAP 28 mm L =180 mm 1.5-6 bar D06F DN25 PN16 MS ~

    73220028 BU G 1 L =180 mm 1.5-6 bar D06F DN25 PN25 MS ~

    73220030 BU G 1 L =180 mm 1.5-12 bar D06FH DN25 PN25 MS ~

    73220034 CAP 35 mm L =200 mm 1.5-6 bar D06F DN32 PN16 MS ~

    73220035 BU G 5/4 L =200 mm 1.5-6 bar D06F DN32 PN16 MS ~

    73220036 BU G 5/4 L =200 mm 1.5-12 bar D06FH DN32 PN25 MS ~

    73220042 BU G 6/4 L =225 mm 1.5-6 bar D06F DN40 PN16 MS ~

    73220043 BU G 6/4 L =225 mm 1.5-12 bar D06FH DN40 PN25 MS ~

    73220944 CAP 42 mm L =225 mm 1.5-6 bar D06F DN40 PN16 MS ~

    73220952 CAP 54 mm L =255 mm 1.5-6 bar D06F DN50 PN16 MS ~

    73220953 BU G 2 L =255 mm 1.5-6 bar D06F DN50 PN16 MS ~

    73220954 BU G 2 L =255 mm 1.5-12 bar D06FH DN50 PN25 MS ~

    73220965 FLANGE NW65 L =290 mm 1.5-8 bar D15P DN65 PN16 GG pressure gauge(s)

    optional

    73220980 FLANGE NW80 L =310 mm 1.5-8 bar D15P DN80 PN16 GG pressure gauge(s)optional

    73220989 FLANGE NW100 L =350 mm 1.5-8 bar D15P DN100 PN16 GG pressure gauge(s)

    optional

    73220990 FLANGE NW125 L =400 mm 1.5-8 bar D15P DN125 PN16 GG pressure gauge(s)

    optional

    73229928 ~ G 1 - G 5/4 ~ ~ ~ PN16 PVC FILTER POT

    73229943 ~ G 6/4 - G 2 ~ ~ ~ PN16 PVC FILTER POT

    73229944 ~ G 6/4 - G 2 ~ ~ ~ PN25 MS FILTER POT

    73239942 ~ G 6/4 - G 2 ~ ~ ~ ~ ~ FILTER

    73409142 ~ G 1 - G 5/4 ~ ~ ~ ~ ~ FILTER

    73409143 ~ G 1 - G 5/4 ~ D06FH ~ ~ ~ FILTER

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    62/64

    62

    Figure 51: (73220023) 3244/24072008

    Figure 52: (DO6 ..) 3245/24072008

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    63/64

    63

    5 Annex

    5.1 St ructure of arti cle numbers

    Table 42: Structure of article numbers

    Structure of article numbers

    Istalla

    tion

    type

    Num

    bero

    fpumps

    Pump

    type

    Pumps

    ize

    Stages

    Re

    duce

    ds

    tages

    Ma

    teria

    l+pressurec

    lass

    Man

    ifo

    lds

    Con

    tro

    l

    star

    tingme

    tho

    d

    Cons

    truc

    tion

    Descr

    iption

    Des

    ignvers

    ion

    HU 1 2 3 4 5 6 7 8 9 10

    2 2 pumps

    3 3 pumps

    1 VME

    2 VE

    2 2 B

    4 4 B

    6 6 B

    A 10 B

    2 2 stages

    3 3 stages

    4 4 stages

    5 5 stages6 6 stages

    7 7 stages

    8 8 stages

    9 9 stages

    A 10 stages

    B 11 stages

    1 AISI 304 PN10

    2 AISI 304 PN16

    C G 5/4

    D G 6/4

    E G 2

    1 DPC

    2 DPC HR

    6 MCMF (FR)

    1 DOL

    4 FRK

    N COMPACT CONSTRUCTION (HU DPVE)

  • 7/28/2019 Hydro-Unit Technical Data Premium Line

    64/64

    dp pumps

    P.O. Box 28

    2400 AA Alphen aan den Rijn

    The Netherlands

    t +31 172 48 83 88

    f+31 172 46 89 30

    [email protected]

    www.dp-pumps.com

    08/2012

    97004467-E

    Can be changed without prior notice