husky 1050 air-operated diaphragm pump 2020-04-01آ  repair/parts huskyآ® 1050 air-operated...

Download Husky 1050 Air-Operated Diaphragm Pump 2020-04-01آ  Repair/Parts Huskyآ® 1050 Air-Operated Diaphragm

Post on 06-Apr-2020

1 views

Category:

Documents

0 download

Embed Size (px)

TRANSCRIPT

  • Repair/Parts

    Husky® 1050 Air-Operated Diaphragm Pump 313435ZAJEN

    1-inch pump with modular air valve for fluid transfer applications. For professional use only.

    See page 4 for model information, including approvals. 125 psi (0.86 MPa, 8.6 bar) Maximum Fluid Working Pressure 125 psi (0.86 MPa, 8.6 bar) Maximum Air Input Pressure

    Center Flange

    ti13844a

    ti13843a

    End Flange

    1050P Polypropylene 1050C Conductive

    Polypropylene 1050F PVDF

    Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.

    1050S Stainless Steel 1050H Hastelloy

    ti14342a

    1050A Aluminum

    ti13946a

  • Related Manuals

    2 313435ZAJ

    Contents Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 To Find Your Nearest Distributor . . . . . . . . . . . . . . 3 To Specify the Configuration of a New Pump . . . . 3 To Order Replacement Parts . . . . . . . . . . . . . . . . . 3 Distributor Note . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Pump Matrix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 ATEX Certifications . . . . . . . . . . . . . . . . . . . . . . . . . 5 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

    Pressure Relief Procedure . . . . . . . . . . . . . . . . . 8 Repair or Replace Air Valve . . . . . . . . . . . . . . . . 8 DataTrak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Check Valve Repair . . . . . . . . . . . . . . . . . . . . . 12 Diaphragms and Center Section . . . . . . . . . . . . 13 Torque Instructions . . . . . . . . . . . . . . . . . . . . . . 16

    Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Parts/Kits Quick Reference . . . . . . . . . . . . . . . . 18 Center Section . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Air Valve and Data Monitoring . . . . . . . . . . . . . . 21 Fluid Covers and Manifolds . . . . . . . . . . . . . . . . 23 Seats and Check Ball . . . . . . . . . . . . . . . . . . . . 25 Diaphragms . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Seat, Check Ball, and Diaphragm Kits . . . . . . . 28 Manifold O-Rings . . . . . . . . . . . . . . . . . . . . . . . . 29 DataTrak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

    Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Graco Standard Husky Pump Warranty . . . . . . . . 34 Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . 34

    Related Manuals

    Manual Description

    312877 Husky 1050 Air-Operated Diaphragm Pump, Operation

    313597 Husky 1050A UL-Listed Diaphragm Pump, Operation

    313598 Husky 1050A CSA-Compliant Diaphragm Pumps, Operation

    313840 DataTrak, Instructions/Parts

    406824 Pulse Count Kits, Instructions

    406825 Reed Switch with Solenoid Kits, Instructions

    406826 Torque Instructions (Manifolds and Fluid Covers)

  • To Find Your Nearest Distributor

    313435ZAJ 3

    To Find Your Nearest Distributor

    1. Visit www.graco.com.

    2. Click on Where to Buy and use the Distributor Locator.

    To Specify the Configuration of a New Pump Please call your distributor.

    OR

    Use the Online Diaphragm Pump Selector Tool at www.graco.com.

    To Order Replacement Parts Please call your distributor.

    Distributor Note 1. To find part numbers for new pumps or kits, use the Online Diaphragm Pump Selector Tool.

    2. To find part numbers for replacement parts:

    a. Use the configuration number from the ID plate on the pump. If you only have the Graco 6-digit part num- ber, use the selector tool to find the corresponding configuration number.

    b. Use the Configuration Number Matrix on the next page to understand which parts are described by each digit.

    c. Refer to the main Parts illustration and to the Parts/Kits Quick Reference. Follow the page references on these two pages for further ordering information, as needed.

    3. Please call Graco Customer Service to order.

    http://www.graco.com http://wwwd.graco.com/training/husky/index.html

  • Pump Matrix

    4 313435ZAJ

    Pump Matrix Check the identification plate (ID) for the Configuration Number of your pump. Use the following matrix to define the components of your pump.

    Sample Configuration Number: 1050A-PA01AA1SSBNBNPT

    1050 A P A01A A1 SS BN BN PT Pump Size

    Wetted Section Material

    Drive Identifier

    Center Section and Air Valve

    Fluid Covers and Manifolds

    Seats Balls Diaphragms Manifold O-Rings

    Pump Size

    Wetted Section Material

    Drive Identifier

    Center Section and Air Valve Material

    Air Valve/Monitoring

    Fluid Covers and Manifolds

    1050 A Aluminum P Pneumatic

    Aluminum

    A01A Standard A1 Aluminum, standard ports, inch 1050 C Conductive

    Polypropylene A01B Pulse Count  A2 Aluminum, standard ports, metric A01C DataTrak  C1 Conductive polypropylene,

    center flange1050 F PVDF A01D Remote 1050 H‡ Hastelloy A01E Optional FKM Seals C2 Conductive polypropylene, end

    flange1050 P Polypropylene AC1A CSA-Compliant 1050 S‡ Stainless Steel AU1A UL-Listed; Fuel

    transfer F1 PVDF, center flange

    AU3A UL-Listed; Fuel dispense

    F2 PVDF, end flange

    Conductive Polypropylene

    C01A Standard H1 Hastelloy, standard ports, inch C01B Pulse Count  H2 Hastelloy, standard ports, metric C01C DataTrak  P1 Polypropylene, center flange C01D Remote P2 Polypropylene, end flange

    Polypropylene

    P01A Standard S1 Stainless steel, standard ports, inchP01B Pulse Count

    P01C DataTrak S2 Stainless steel, standard ports, metricP01D Remote

    S5-1 Stainless steel, center flange, horizontal outlet port

    , ‡, , or : See ATEX Certifications, page 5.

    Contains pressure relief valve.

    S5-2 Stainless steel, center flange, vertical outlet port

    CONFIGURATION NO.PART NO. SERIAL NO.

    SERIESDATE CODE MAX WPR PSI-bar MADE IN

    ID

    ti14103a

    Check Valve Seats Check Valve Balls Diaphragm Manifold O-Rings

    AC Acetal AC Acetal BN Buna-N — Models with Buna-N, FKM Fluoroelasto- mer or TPE seats do not use o-rings.

    AL Aluminum BN Buna-N CO Polychloroprene Overmolded

    BN Buna-N CR Polychloroprene Standard FK FKM Fluoroelastomer

    FK FKM Fluoroelastomer CW Polychloroprene Weighted GE Geolast

    GE Geolast® FK FKM Fluoroelastomer PO PTFE/EPDM Overmolded

    PP Polypropylene GE Geolast PS PTFE/Santoprene Two-Piece PT PTFE

    PV PVDF PT PTFE PT PTFE/EPDM Two-Piece

    SP Santoprene® SP Santoprene SP Santoprene

    SS 316 Stainless Steel SS 316 Stainless Steel TP TPE

    TP TPE TP TPE

  • ATEX Certifications

    313435ZAJ 5

    ATEX Certifications

    Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. When these symbols appear in the body of this manual, refer back to these Warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.

     All 1050A (Aluminum) and 1050C (Conductive Polypropylene) pumps are certified:

    ‡ 1050S (Stainless Steel) and 1050H (Hastelloy) pumps with aluminum or conductive polypropylene centers are certified:

     1050A (Aluminum) and 1050C (Conductive Polypropylene) pumps with DataTrak or Pulse Count AND 1050S (Stainless Steel) and 1050H (Hastelloy) pumps with aluminum or conductive polypropylene centers and fitted with DataTrak or Pulse Count are certified:

    II 2 GD II 2 GD II 2(1) G Ex h IIC 66°C...135°C Gb Ex h IIIC T135°C Db

    Ex h IIC 66°C...135°C Gb Ex h IIIC T135°C Db

    Ex h [ia Ga] IIA T3 Gb X

    ATEX T-code rating is dependent on the temperature of the fluid being pumped. Fluid temperature is limited by the materials of the pump interior wetted parts. See Technical Data for the maximum fluid operating temperature for your specific pump model.

     DataTrak and Pulse Count are certified:

    II 1 G 9902471

    Class I, Div. 1, Group D T3A

    Ex ia IIA T3 Ga ITS13ATEX27862X

    2575

    WARNING FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: • Use equipment only in well ventilated area. • Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop

    cloths (potential static arc). • Keep work area free of debris, including solvent, rags and gasoline. • Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes

    are present. • Ground all equipment in the work area. See Grounding instructions. • Use only grounded hoses. • Hold gun firmly to side of grounded pail when triggering into pail. • If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment

    until you identify and correct the problem. •

Recommended

View more >