HIGH-POWERH E AT PU M PS

Up to300 kW

1

Page 2: High power heat pumps catalogue en 2014 pdf

2

Page 3: High power heat pumps catalogue en 2014 pdf

4 COMPLETE RANGE OF NEW GENERATION HIGH-POWER HEAT PUMPS

8 MODERN CONTROL UNIT

HEAT PUMPS AIR-WATER

10 Heat pumps AEROGOR COMPACT W

11 Heat pumps AEROGOR COMPACT EVI W

12 Heat pumps AEROGOR SPLIT AW W

13 Heat pumps AEROGOR SPLIT AW EVI W

14 Heat pumps AEROGOR SPLIT HD W

15 Heat pumps AEROGOR SPLIT HD EVI W

GEOTHERMAL HEAT PUMPS BRINE-WATER AND WATER-WATER

18 Heat pumps AQUAGOR – TERRAGOR W

19 Heat pumps AQUAGOR – TERRAGOR EVI W

20 Table of recommended circulating pumps

21 Operating range

22 Technical specification

NEW GENERATION OF HEAT PUMPS GORENJE

3

Page 4: High power heat pumps catalogue en 2014 pdf

Model name Outlet water temperature

Number of compressors

Aerogor Compact 25 – 54 W 60°C 1

Aerogor Compact EVI 27 – 56 W 65°C 1

Model name Outlet water temperature

Number of compressors

Aerogor Split AW 25 – 54 W 60°C 1

Aerogor Split AW EVI 20 – 55 W 65°C 1

Model name Outlet water temperature

Number of compressors

Aerogor Split HD 107 W 60°C 2

Aerogor Split HD EVI 109 W 65°C 2

COMPLETE RANGEOF NEW GENERATION HIGH-POWER HEAT PUMPS

4

Page 5: High power heat pumps catalogue en 2014 pdf

Model name Outlet water temperature

Number of compressors

Aerogor Split HD EVI 163 W 65°C 3

Model name Outlet water temperature

Number of compressors

Aquagor 37 W 60°C 2

Terragor 28 W 60°C 2

Model name Outlet water temperature

Number of compressors

Aquagor 50 - 115W 60°C 2

Terragor 38 - 83 W 60°C 2

Aquagor EVI 48 - 126W 65°C 2

Terragor EVI 37 - 98 W 65°C 2

5

Page 6: High power heat pumps catalogue en 2014 pdf

The heat pump reaches high temperatures of heating water; therefore, it is also suitable for conventional radiator systems. It is appropriate for both floor heating and radiator heating system (with higher heating water requirements of up to 65 °C).

HIGHTEMPERATURE OPERATION

The system can successfully operate down to environment temperatures of -20 °C.

OPERATION ATENVIRONMENT TEMPERATURE

OF DOWN TO -20°C

-20 °C

Efficient operation with high coefficient of performance – excellent COP.

LOWOPERATING COSTS

It is allowed by the scroll compressor technology, top-class sound insulation, and ultra-silent axial fan.

SILENT AND RELIABLEOPERATION

Components by European manufacturers are installed in the heat pump, which guarantees quality and long useful life.

EUROPEANQUALITY

MAIN ADVANTAGESOF HEAT PUMP WATER HEATERS

6

Page 7: High power heat pumps catalogue en 2014 pdf

Economical and efficient heating system with Gorenje heat pumps is a smart choice for both new and existing buildings. High-power heat pumps are intended for larger buildings housing, for example, public institutions (schools, kindergardens, banks etc.) or smaller to medium-sized industrial and commercial premises (offices, sports halls, restaurants etc.). They are suitable for both low-temperature heating systems (new buildings with floor heating or low-temperature radiators) and buildings with high-temperature heating systems with conventional radiators (refurbished or older buildings) as they can heat the water to a temperature of 55 to 65 °C.

We offer two types of high-power geothermal heat pumps:

• Aquagor W water/water heat pumps with heating capacity ranging from 37 to 115 kW.

• Terragor W brine/water heat pumps with heating capacity ranging from 28 to 83 kW.

Aquagor EVI W water/water heat pump with heating capacity ranging from 48 to 126 kW.

Terragor EVI W brine/water heat pumps with heating capacity ranging from 37 to 98 kW.

• Moreover, we offer different types of air-water heat pumps with wide range of heating capacity (20 - 163 kW):

• Aerogor Compact 25 - 54 W• Aerogor Compact EVI 27 - 56 W• Aerogor Split AW 25 - 54 W• Aerogor Split AW EVI 20 - 55 W• Aerogor Split HD 107 W• Aerogor Split HD EVI 109/163 W

Characteristics of high-power heat pumps:

• Geothermal heat pumps operate in two levels/cycles: Two compressors operate in a cascade system to allow the adjustment of heating power to the heating requirements of the building in different periods of the heating season.

• High-temperature heat pumps can heat the water to a temperature of 65 °C:

• Aerogor Compact EVI W / Split AW EVI W / Split HD EVI W

• Terragor EVI W• Aquagor EVI W

• Low-temperature heat pumps can heat the water to a temperature of 55 to 60 °C:

• Aerogor Compact W / Split AW W / Split HD W• Terragor W• Aquagor W

• Complete range or air-water heat pumps allows active cooling mode during the hot summer months (serial integrated 4- way reversible valve and electronic expanison valve enables this procces).

• Geothermal heat pumps (brine-water / water- water) allows passive cooling mode in combination with pre-heat exchanger. Active cooling mode - optionally (on the request).

HEATING MODE

DOMESTIC HOT WATER

ACTIVE COOLING

HEATING MODE

DOMESTIC HOT WATER

ACTIVE/PASIVE COOLING

The heat pumps can operate in cascade system:

ECONOMICAL AND EFFICIENTGORENJE HIGH-POWER HEAT PUMPS ARE INTENDED FOR LARGE BUILDINGS

60/65°C

7

Page 8: High power heat pumps catalogue en 2014 pdf

Modern control unit allows different settings for heating, cooling, and domestic hot water heating. The regulation is weather-dependent. The control unit regulates the heat pump and heating system operation according to the outdoor environment temperature and the desired indoor temperature in the user’s home. Owing to a special algorithm, the heat pump only generates as much heat as required by the heating system, in any given moment.

Basic regulation

Basic regulation of RVS 61 supports two independent heating circuits – one direct and one mixing circuit. For each circuit, the heating curve is set independently. Basic regulation of RVS 21 supports regulation of one direct heating circuit and DHW circuit. Basic regulation (RVS 61 and RVS 21) also supports heating of sanitary water with anti-Legionella program, as well as alternative sources such as solar panels or wood-fired furnaces. It also allows hassle-free regulation of additional sources such as a heating oil or gas burner. Electronic controls are universal for all types of heat pumps and heating methods. In case of major systems, upgrading the basic regulation unit is quite straightforward. In most cases, heating circuit regulation depends on the exterior temperature. The heating curve depends on the characteristics of the building being heated, which is the only warranty that the heat pump, regardless of the outdoor temperature, will always heat the water to the lowest acceptable temperature. The level of temperature thus defines the efficiency of the heating system. The lower the heating temperature, the higher the Coefficient of Performance.

Easy control

Menu navigation is plain and simple. Each screen is indicated with a consecutive number so that the user is aware at all times which page of the menu is currently open. Commands re indicated with appropriate wording. The unit can be controlled via user keyboard on the heat pump, or through an additional room control unit. Basic functions are available through keys on the control unit and heating system temperature is easily set with a rotating dial located in the middle of the control unit. For advanced users, controls can also be routed hrough interfaces to a personal computer or even to an intelligent home system.

RVS 21 RVS 61

Aerogor Compact 25 – 54 W Yes

Aerogor Compact EVI 27 – 56 W Yes

Aerogor Split AW 20 – 54 W Yes

Aerogor Split AW EVI 25 – 55 W Yes

Aerogor Split HD 107 W Yes

Aerogor Split HD EVI 109 W Yes

Aerogor Split HD EVI 163 W Yes

Aquagor – Terragor W Yes

Aquagor – Terragor EVI W Yes

INSTALLED HP CONTROLLER SIEMENS RVS 61

Control of direct HC*: Yes

Control of DHW circuit: Yes

Control active/passive cooling mode: Yes

Control of mixing HC*: Yes

Control of direct pump HC*: Yes

Solar system control: Yes

*HC = heating circuit

INSTALLED HP CONTROLLER SIEMENS RVS 21

Control of direct HC*: Yes

Control of DHW circuit: Yes

Active cooling mode: Yes

Control of mixed HC*: with EXM**

Control of direct pump HC*: with EXM**

Solar system control: with EXM**

*HC = heating circuit**EXM = Extension module

MODERN CONTROL UNIT

8

Page 9: High power heat pumps catalogue en 2014 pdf

Smart Web - remote control

The Smart Web application allows you to monitor your heat pump operation regardless of where you are. An internet connection can be used to connect the heat pump controllers to your personal computer or your cell phone. Thus, the system allows you to monitor the settings, to keep up to date with the device operating status, and to receive a warning in case of any failures. This makes remote control of your heating system convenient as well as cost and energy-effective due to constant control over equipment operation.

Electronic control enable regulation of different heating systems

Large buildings in lot of cases need for different parts of the building – different temperature regulation. Control units of heat pumps Gorenje enable regulation of different heating/cooling zones. Here are solutions for some cases.

Regulation of different heating zones with control unit Siemens RVS 61

CASE 1: 3 HEATING ZONES WITH 3 MIXING HEATING CIRCUITS:

1st mixing heating circuit:

• controlled by Basic control unit RVS 61

2nd mixing heating circuit:

• Extension module Siemens AVS75.390/109

• 1 x NTC temperature sensor

3rd mixing heating circuit:

• Extension module RVS46.530/101

• 1 x NTC temperature sensor

• Room unit advanced/cooling/wired QAA75.611/701

CASE 2: 3 HEATING ZONES WITH 1 DIRECT AND 2 MIXING CIRCUITS:

1st direct heating circuit:

• controlled by Basic control unit RVS 61

1st mixing heating circuit:

• controlled by Basic control unit RVS 61

2nd mixing heating circuit:

• Extension module AVS75.390/109

• 1 x NTC Temperature sensor

CASE 3: 3 ZONES WITH 3 DIRECT HEATING CIRCUITS:

1st and 2nd direct heating circuit:

• controlled by Basic control unit RVS 61

3rd direct heating circuit:

• Extension module Siemens AVS75.390/109

• 1 x NTC temperature sensor

Regulation of different heating zones with control unit Siemens RVS 21

CASE 1: 3 HEATING ZONES WITH 3 MIXING HEATING CIRCUITS:

1st mixing heating circuit:

• Extension module Siemens AVS75.390/109

• 1 x NTC temperature sensor

2nd mixing heating circuit:

• Extension module Siemens AVS75.390/109

• 1 x NTC temperature sensor

3rd mixing heating circuit:

• Extension module RVS46.530/101

• 1 x NTC temperature sensor

• Room unit advanced/cooling/wired QAA75.611/701

CASE 2: 3 HEATING ZONES WITH 1 DIRECT AND 2 MIXING CIRCUITS:

1st direct heating circuit:

• controlled by Basic control unit RVS 21

2nd mixixng heating circuit:

• Extension module Siemens AVS75.390/109

• 1 x NTC temperature sensor

3rd direct heating circuit:

• Extension module Siemens AVS75.390/109

• 1 x NTC temperature sensor

CASE 3: 3 ZONES WITH 3 DIRECT HEATING CIRCUITS:

1st direct heating circuit:

• controlled by Basic control unit RVS 21

2nd direct heating circuit:

• Extension module Siemens AVS75.390/10

• 1 x NTC temperature sensor

3nd direct heating circuit:

• Extension module Siemens AVS75.390/109

• 1 x NTC temperature sensor

Internet

Ethernet

Heat pump electronic control unit

USB

OZW 164

Alarm email

9

Page 10: High power heat pumps catalogue en 2014 pdf

HEAT PUMPS AEROGOR COMPACT WAIR – WATER AEROGOR COMPACT 25 – 54 W

MAIN ADVANTAGES

Max. Outlet water temperature: 60°C (55°C up to ambient temperature -15°C)

High efficiency Scroll ZH compressor (1 X)

SWEP heat exchanger

Tilting compact electro box with safety elements and control system

1 x EEV (electonic expansion valve) + 1 x TEV (thermo expansion valve)

Special V form of evaporator

Evaporator heat exchanger frost free in the lower part – APS System

Multi layer sound insulation

Safety elements for protection:• Flow switch build-in• Pressure switch heating water (0,7 bar)• Soft start module for compressor (Danfoss)• Motor protection for compressor• Crankcase heater for compressor• Motor protection for fan• Phase direction control• High tariff lock• Compressor over clock protection

The main components and temperature sensors

Compact outdoor unit

LEGEND

Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: AB84: temperature sensor 1 of source side (evaporator)B91: temperature sensor 2 of source side (evaporator)K1/E11: compressor 1 Type: Copeland scroll ZH High efficiency and quite scroll technology Long life periodB21: water outlet temperature sensor (condenser)B71: water inlet temperature sensor (condenser)Y22: 4-way reversible valveK19/E14: Fan motor

Indoor unit

Operating modes

DOMESTICHOT WATER

HEATINGMODE

ACTIVECOOLING

Basic: DisplayBox W• Display of control unit (HMI)• Heating/Cooling mode

Advanced: ControlBox W• main power switch• display from control unit• 1 x extension module AVS75.370• Heating/Cooling/DHW mode

ACCESSORIES LIST

• 10 meter LAN cable with RJ45 connectors• 1 x Outdoor temperature sensor

for weather-dependent regulation• 2 x cable temperature (+5 to 95°C) sensors

in the package

HIGHTEMPERATURE OPERATION

10

Page 11: High power heat pumps catalogue en 2014 pdf

HEAT PUMPS AEROGOR COMPACT EVI WAIR – WATER AEROGOR COMPACT EVI 27 – 56 W

MAIN ADVANTAGES

Max. Outlet water temperature: 65°C (up to ambient temperature -20°C)

High efficiency Scroll EVI compressor (1 X)

SWEP heat exchanger

Tilting compact electro box with safety elements and control system

1 x EEV (electonic expansion valve) + 1 x TEV (thermo expansion valve)

Special V form of evaporator

Evaporator heat exchanger frost free in the lower part – APS System

Multi layer sound insulation

Serial integrated circulating pump

Safety elements for protection:• Flow switch build-in• Pressure switch heating water (0,7 bar)• Soft start module for compressor (Danfoss)• Motor protection for compressor• Crankcase heater for compressor• Motor protection for fan• Phase direction control• High tariff lock• Compressor over clock protection

The main components and temperature sensors

Compact outdoor unit

LEGEND

Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: AB84: temperature sensor 1 of source side (evaporator)B91: temperature sensor 2 of source side (evaporator)K1/E11: compressor 1 Type: Copeland scroll ZH EVI Extreme good performances Long life periodB21: water outlet temperature sensor (condenser)B71: water inlet temperature sensor (condenser)Y22: 4-way reversible valveK19/E14: Fan motor

Indoor unit

Operating modes

DOMESTICHOT WATER

HEATINGMODE

ACTIVECOOLING

Basic: DisplayBox W• Display of control unit (HMI)• Heating/Cooling mode

Advanced: ControlBox W• main power switch• display from control unit• 1 x extension module AVS75.370• Heating/Cooling/DHW mode

ACCESSORIES LIST

• 10 meter LAN cable with RJ45 connectors• 1 x Outdoor temperature sensor

for weather-dependent regulation• 2 x cable temperature (+5 to 95°C) sensors

in the package

HIGHTEMPERATURE OPERATION

11

Page 12: High power heat pumps catalogue en 2014 pdf

HEAT PUMPS AEROGOR SPLIT AW WAIR – WATER AEROGOR SPLIT AW 25 – 54 W

MAIN ADVANTAGES

Max. Outlet water temperature: 60°C (55°C up to ambient temperature -15°C)

High efficiency Scroll ZH compressor (1 X)

SWEP heat exchanger

Tilting compact electro box with safety elements and control system

1 x EEV (electonic expansion valve) + 1 x TEV (thermo expansion valve)

Special V form of evaporator

Evaporator heat exchanger frost free in the lower part – APS System

Multi layer sound insulation

Safety elements for protection:• Flow switch build-in• Pressure switch heating water (0,7 bar)• Soft start module for compressor (Danfoss)• Motor protection for compressor• Crankcase heater for compressor• Motor protection for fan• Phase direction control• High tariff lock• Compressor over clock protection

The main components and temperature sensors

Compact outdoor unit

LEGEND

Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: AB84: temperature sensor 1 of source side (evaporator)B91: temperature sensor 2 of source side (evaporator)K1/E11: compressor 1 Type: Copeland scroll ZH High efficiency and quite scroll technology Long life periodB21: water outlet temperature sensor (condenser)B71: water inlet temperature sensor (condenser)Y22: 4-way reversible valveK19/E14: Fan motor

Indoor unit

Operating modes

DOMESTICHOT WATER

HEATINGMODE

ACTIVECOOLING

ACCESSORIES LIST

• 1 x Outdoor temperature sensor for weather-dependent regulation

• 2 x cable temperature (+5 to 95°C) sensors in the package

HIGHTEMPERATURE OPERATION

12

Page 13: High power heat pumps catalogue en 2014 pdf

HEAT PUMPS AEROGOR SPLIT AW EVI WAIR – WATER AEROGOR SPLIT AW EVI 20 – 55 W

MAIN ADVANTAGES

Max. Outlet water temperature: 65°C (up to ambient temperature -20°C)

High efficiency Scroll EVI compressor (1 X)

SWEP heat exchanger

Tilting compact electro box with safety elements and control system

1 x EEV (electonic expansion valve) + 1 x TEV (thermo expansion valve)

Special V form of evaporator

Evaporator heat exchanger frost free in the lower part – APS System

Multi layer sound insulation

Serial integrated circulating pump

Safety elements for protection:• Flow switch build-in• Pressure switch heating water (0,7 bar)• Soft start module for compressor (Danfoss)• Motor protection for compressor• Crankcase heater for compressor• Motor protection for fan• Phase direction control• High tariff lock• Compressor over clock protection

The main components and temperature sensors

Compact outdoor unit

LEGEND

Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: AB84: temperature sensor 1 of source side (evaporator)B91: temperature sensor 2 of source side (evaporator)K1/E11: compressor 1 Type: Copeland scroll ZH EVI Extreme good performances Long life periodB21: water outlet temperature sensor (condenser)B71: water inlet temperature sensor (condenser)Y22: 4-way reversible valveK19/E14: Fan motor

Indoor unit

Operating modes

DOMESTICHOT WATER

HEATINGMODE

ACTIVECOOLING

ACCESSORIES LIST

• 1 x Outdoor temperature sensor for weather-dependent regulation

• 2 x cable temperature (+5 to 95°C) sensors in the package

HIGHTEMPERATURE OPERATION

13

Page 14: High power heat pumps catalogue en 2014 pdf

HEAT PUMPS AEROGOR SPLIT HD WAIR – WATER AEROGOR SPLIT HD 107 W

MAIN ADVANTAGES

Max. Outlet water temperature: 60°C (up to ambient temperature -15°C)

2 X High efficiency Scroll ZH compressor

SWEP heat exchanger

Tilting compact electro box with safety elements and control system

2 x EEV (electonic expansion valve) + 2 x TEV (thermo expansion valve)

Special V form of evaporator

Evaporator heat exchanger frost free in the lower part – APS System

Multi layer sound insulation

Without serial integrated circulating pump

Safety elements for protection:• Flow switch build-in• Pressure switch heating water (0,7 bar)• Soft start module for compressor (Danfoss)• Motor protection for compressor• Crankcase heater for compressor• Motor protection for fan• Phase direction control• High tariff lock• Compressor over clock protection

The main components and temperature sensors

LEGEND

Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: AB84: temperature sensor 1 of source side (evaporator)B91: temperature sensor 2 of source side (evaporator)K1/E11: compressor 1 and 2 Type: Copeland scroll ZH High efficiency and quite scroll technology Long life periodB21: water outlet temperature sensor (condenser)B71: water inlet temperature sensor (condenser)Y22: 4-way reversible valveK19/E14: Fan motor

Operating modes

DOMESTICHOT WATER

HEATINGMODE

ACTIVECOOLING

ACCESSORIES LIST

• 1 x Outdoor temperature sensor for weather-dependent regulation

• 2 x cable temperature (+5 to 95°C) sensors in the package

HIGHTEMPERATURE OPERATION

Outdoor unit 1 Outdoor unit 2 Indoor unit (2 x compressors)

14

Page 15: High power heat pumps catalogue en 2014 pdf

HEAT PUMPS AEROGOR SPLIT HD EVI WAIR – WATER AEROGOR SPLIT HD EVI 109 W

MAIN ADVANTAGES

Max. Outlet water temperature: 65°C (up to ambient temperature -20°C)

2 X High efficiency Scroll EVI compressor

SWEP heat exchanger

Tilting compact electro box with safety elements and control system

2 x EEV (electonic expansion valve) + 2 x TEV (thermo expansion valve)

Special V form of evaporator

Evaporator heat exchanger frost free in the lower part – APS System

Multi layer sound insulation

Without serial integrated circulating pump

Safety elements for protection:• Flow switch build-in• Pressure switch heating water (0,7 bar)• Soft start module for compressor (Danfoss)• Motor protection for compressor• Crankcase heater for compressor• Motor protection for fan• Phase direction control• High tariff lock• Compressor over clock protection

The main components and temperature sensors

LEGEND

Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: AB84: temperature sensor 1 of source side (evaporator)B91: temperature sensor 2 of source side (evaporator)K1/E11: compressor 1 and 2 Type: Copeland scroll ZH EVI Extreme good performances Long life periodB21: water outlet temperature sensor (condenser)B71: water inlet temperature sensor (condenser)Y22: 4-way reversible valveK19/E14: Fan motor

Operating modes

DOMESTICHOT WATER

HEATINGMODE

ACTIVECOOLING

ACCESSORIES LIST

• 1 x Outdoor temperature sensor for weather-dependent regulation

• 2 x cable temperature (+5 to 95°C) sensors in the package

HIGHTEMPERATURE OPERATION

Outdoor unit 1 Outdoor unit 2 Indoor unit (2 x compressors)

15

Page 16: High power heat pumps catalogue en 2014 pdf

HEAT PUMPS AEROGOR SPLIT HD EVI WAIR – WATER AEROGOR SPLIT HD EVI 163 W

MAIN ADVANTAGES

Max. Outlet water temperature: 65°C (up to ambient temperature -20°C)

3 X High efficiency Scroll EVI compressor

SWEP heat exchanger

Tilting compact electro box with safety elements and control system

3 x EEV (electonic expansion valve) + 3 x TEV (thermo expansion valve)

Special V form of evaporator

Evaporator heat exchanger frost free in the lower part – APS System

Multi layer sound insulation

Without serial integrated circulating pump

Safety elements for protection:• Flow switch build-in• Pressure switch heating water (0,7 bar)• Soft start module for compressor (Danfoss)• Motor protection for compressor• Crankcase heater for compressor• Motor protection for fan• Phase direction control• High tariff lock• Compressor over clock protection

The main components and temperature sensors

LEGEND

Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: AB84: temperature sensor 1 of source side (evaporator)B91: temperature sensor 2 of source side (evaporator)K1/E11: compressors 1, 2, 3 Type: Copeland scroll ZH EVI Extreme good performances Long life periodB21: water outlet temperature sensor (condenser)B71: water inlet temperature sensor (condenser)Y22: 4-way reversible valveK19/E14: Fan motor

Operating modes

DOMESTICHOT WATER

HEATINGMODE

ACTIVECOOLING

ACCESSORIES LIST

• 1 x Outdoor temperature sensor for weather-dependent regulation

• 2 x cable temperature (+5 to 95°C) sensors in the package

HIGHTEMPERATURE OPERATION

Outdoor unit 1 Outdoor unit 2 Outdoor unit 3 Indoor unit (3 x compressors)

16

Page 17: High power heat pumps catalogue en 2014 pdf

17

Page 18: High power heat pumps catalogue en 2014 pdf

GEOTHERMAL HEAT PUMPS BRINE-WATER AND WATER-WATERHEAT PUMPS AQUAGOR – TERRAGOR W

The main components and temperature sensors

LEGEND

Q8: circulating pump on source sideQ9: circulating pump on the secondary side (condenser)B91: inlet temperature sensor of source side (evaporator)B92: outlet temperature sensor of source side (evaporator)K1 / E11: compressor 1K2 / E12: compressor 2B21: water outlet temperature sensor (condenser)B71: water inlet temperature sensor (condenser)

Operating modes

DOMESTICHOT WATER

HEATINGMODE

ACTIVE/PASIVECOOLING

ACCESSORIES LIST

• 1 x Outdoor temperature sensor for weather-dependent regulation

• 2 x cable temperature (+5 to 95°C) sensors in the package

HIGHTEMPERATURE OPERATION

Geothermal heat pumps operate in two levels/cycles:

Two compressors operate in a cascade system to allow the adjustment of heating power to the heating requirements of the building in different periods of the heating season.

MAIN ADVANTAGES

Max. Outlet water temperature: 60°C

Passive cooling mode• Reverse active cooling – optional

2 X High efficiency Scroll ZH compressor

SWEP heat exchanger

Tilting compact electro box with safety elements and control system

1 x EEV (electonic expansion valve)• Large surface condenser and evaporator plate heat exchanger • Robust and solid refrigeration cycle designed for highest stability and long

term high performance

Multi layer sound insulation

Without serial integrated circulating pump

Safety elements for protection:• Flow switch build-in• Pressure switch heating water (0,7 bar)• Soft start module for compressor (Danfoss)• Motor protection for compressor• Crankcase heater for compressor• Motor protection for fan• Phase direction control• High tariff lock• Compressor over clock protection

18

Page 19: High power heat pumps catalogue en 2014 pdf

HEAT PUMPS AQUAGOR – TERRAGOR EVI W

The main components and temperature sensors

LEGEND

Q8: circulating pump on source sideQ9: circulating pump on the secondary side (condenser)B91: inlet temperature sensor of source side (evaporator)B92: outlet temperature sensor of source side (evaporator)K1 / E11: compressor 1K2 / E12: compressor 2B21: water outlet temperature sensor (condenser)B71: water inlet temperature sensor (condenser)

Operating modes

DOMESTICHOT WATER

HEATINGMODE

ACTIVE/PASIVECOOLING

ACCESSORIES LIST

• 1 x Outdoor temperature sensor for weather-dependent regulation

• 2 x cable temperature (+5 to 95°C) sensors in the package

HIGHTEMPERATURE OPERATION

Geothermal heat pumps operate in two levels/cycles:

Two compressors operate in a cascade system to allow the adjustment of heating power to the heating requirements of the building in different periods of the heating season.

MAIN ADVANTAGES

Max. Outlet water temperature: 65°C

Passive cooling mode• Reverse active cooling – optional

2 X High efficiency Scroll ZH compressor

SWEP heat exchanger

Tilting compact electro box with safety elements and control system

2 x EEV (electonic expansion valve)• Large surface condenser and evaporator plate heat exchanger • Robust and solid refrigeration cycle designed for highest stability and long

term high performance

Multi layer sound insulation

Without serial integrated circulating pump

Safety elements for protection:• Flow switch build-in• Pressure switch heating water (0,7 bar)• Soft start module for compressor (Danfoss)• Motor protection for compressor• Crankcase heater for compressor• Motor protection for fan• Phase direction control• High tariff lock• Compressor over clock protection

19

Page 20: High power heat pumps catalogue en 2014 pdf

OPERATING RANGEFOR AEROGOR COMPACT W AND AEROGOR COMPACT EVI W

OU

TLE

T W

AT

ER

TE

MP

ER

AT

UR

E [

°C]

25

30

35

40

45

50

55

60

65

70

-10-15-25 -20 -5 0 5 10 15 2520 3530 4540

OPERATING RANGE OF: AEROGOR COMPACT EVI WAEROGOR SPLIT HD EVI W

OUTSIDE AMBIENT TEMPERATURE [°C] Optimum Maximum

OU

TLE

T W

AT

ER

TE

MP

ER

AT

UR

E [

°C]

OUTSIDE AMBIENT TEMPERATURE [°C]

25

30

35

40

45

50

55

60

65

70

-10-15-25 -20 -5 0 5 10 15 2520 3530 4540

OPERATING RANGE OF: AEROGOR COMPACT WAEROGOR SPLIT AW W, AEROGOR SPLIT HD W

20

Page 21: High power heat pumps catalogue en 2014 pdf

OPERATING RANGEFOR AQUAGOR – TERRAGOR W AND AQUAGOR – TERRAGOR EVI W

OU

TL

ET

WA

TE

R T

EM

PE

RA

TU

RE

[°C

]

SOURCE (BRINE) TEMPERATURE [°C]

25

30

35

40

45

50

55

60

65

70

-10 -5 0 5 10 15 20 25 30

OPERATING RANGE TERRAGOR W

OU

TL

ET

WA

TE

R T

EM

PE

RA

TU

RE

[°C

]

SOURCE (WATER) TEMPERATURE [°C]

25

30

35

40

45

50

55

60

65

70

-10 -5 0 5 10 15 20 25 30

OPERATING RANGE AQUAGOR W

OU

TL

ET

WA

TE

R T

EM

PE

RA

TU

RE

[°C

]

SOURCE (BRINE) TEMPERATURE [°C]

25

30

35

40

45

50

55

60

65

70

-10 -5 0 5 10 15 20 25 30

OPERATING RANGE TERRAGOR EVI W

OU

TL

ET

WA

TE

R T

EM

PE

RA

TU

RE

[°C

]

SOURCE (WATER) TEMPERATURE [°C]

25

30

35

40

45

50

55

60

65

70

-10 -5 0 5 10 15 20 25 30

OPERATING RANGE AQUAGOR EVI W

21

Page 22: High power heat pumps catalogue en 2014 pdf

Model name Primary side – source side (brine)*

Secondary side – heating side

Terragor 28 WAquagor 37 W WILO Stratos 40/1-8 WILO Stratos 30/1-8

Terragor 38 WAquagor 50 W WILO Stratos 50/1-8 WILO Stratos 50/1-8

Terragor 43 WAquagor 59 W WILO Stratos 50/1-8 WILO Stratos 50/1-8

Terragor 52 WAquagor 67 W WILO Stratos 50/1-9 WILO Stratos 50/1-8

Terragor 56 WAquagor 78 W WILO Stratos 50/1-9 WILO Stratos 50/1-8

Terragor 65 WAquagor 89 W WILO Stratos 65/1-12 WILO Stratos 65/1-12

Terragor 70 WAquagor 100 W WILO Stratos 80/1-12 WILO Stratos 80/1-12

Terragor 83 WAquagor 115 W WILO Stratos 80/1-12 WILO Stratos 80/1-12

Terragor EVI 67 WAquagor EVI 87 W WILO Stratos 65/1-12 WILO Stratos 65/1-12

Terragor EVI 81 WAquagor EVI 105 W WILO Stratos 80/1-12 WILO Stratos 80/1-12

Terragor EVI 98 WAquagor EVI 126 W WILO Stratos 80/1-12 WILO Stratos 80/1-12

* Valid only for systems brine-water. On the primary (source) side of heat pump water-water must be built-in submersible pump for the underground water. Type of submersible pump is depend on the deepness of borehole of and the distance (pipe length) from borehole to the heat pump.

TABLE OF RECOMMENDED CIRCULATING PUMPSFOR AQUAGOR – TERRAGOR W AND AQUAGOR – TERRAGOR EVI W

22

Page 23: High power heat pumps catalogue en 2014 pdf

Model name Aerogor Split HD 107 W2 x outdoor unit

Aerogor Split HD EVI 109 W2 x outdoor unit

Aerogor Split HD EVI 163 W3 x outdoor unit

Operating modes Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHWCode number 2 x 468624 / 477670 2 x 468624 / 477701 3 x 468624 / 477702Connection between outdoor and indoor unit Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connectionHeating capacity A7/W35 kW 106,60 109,04 163,33COP A7/W35 / 4,77 4,91 4,91Heating capacity A7/W45 kW 102,37 110,31 165,24COP A7/W45 / 3,79 4,04 4,04Heating capacity A7/W55 kW 96,66 112,34 168,28COP A7/W55 / 3,00 3,31 3,31Heating capacity A7/W65 kW / 112,76 168,91COP A7/W65 / / 2,72 2,72Heating capacity A2/W35 kW 86,73 93,46 140,00COP A2/W35 / 3,70 3,80 3,80Heating capacity A2/W45 kW 83,37 94,14 141,02COP A2/W45 / 3,02 3,12 3,12Heating capacity A2/W55 kW 79,21 95,24 142,66COP A2/W55 / 2,39 2,56 2,56Heating capacity A2/W65 kW / 96,25 144,18COP A2/W65 / / 2,10 2,10Heating capacity A-2/W35 kW 72,88 86,49 129,56COP A-2/W35 / 3,32 3,44 3,44Heating capacity A-7/W35 kW 61,22 80,59 120,72COP A-7/W35 / 3,06 3,09 3,09Heating capacity A-15/W35 kW 49,81 67,05 100,43COP A-15/W35 / 2,45 2,59 2,59Maximum outlet water temperature °C 60 65 65Operating range °C -20°C to +40°C -20°C to +40°C -20°C to +40°CActive cooling / yes yes yesCooling capacity - reversible operation A35/W12 kW 68,4 73,6 110,4Power input - reversible operation A35/W12 kW 31 33,4 50,1ERR / 2,2 2,2 2,2Neto weight - outdoor unit kg 410 450 740Neto weight - indoor unit kg 2 x 185 2 x 185 3 x 185Dimensions of outdoor unit (W x D x H) mm 1050 x 1700 x 1530 1050 x 1700 x 1530 1050 x 1700 x 1530Dimensions of indoor unit (W x D x H) mm 1233 x 1371 x 1300 1233 x 1371 x 1300 1233 x 1371 x 1300Voltage V/Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 HzNoise emissions [5m] - indoor unit dB 59 59 61Noise emissions [8m] - outdoor unit dB 69 69 73Connecting dimensions – primary side mm 2 x (22 mm / 35 mm) 2 x (22 mm / 35 mm) 3 x (22 mm / 35 mm)Connecting dimensions – secondary side ” 1 1/2” 1 1/2” 1 1/2”Type of screw thread - outdoor unit / inner inner innerAir flow - primary side m3/h 2 x 14.067 2 x 14.067 3 x 14.067Nominal water flow - secondary side m3/h 2 x 5,1 2 x 5,7 3 x 5,7Pressure drop - primary side kPa 2 x 0,061 2 x 0,061 3 x 0,061Pressure drop - secondary side kPa max 20 max 20 max 20Recommended temperature difference (flow / return) K 7 7 7Main connection cable – dimension mm2 5 x 25 mm2 5 x 25 mm2 5x25 mm2

Power connection (indoor - outdoor unit) mm2 2 x 3 x 1,5 mm2 2 x 3 x 1,5 mm2 3 x 3 x 1,5 mm2

Electrical connection cable between indoor - outdoor unit [sheathed] mm2 2 x 10 x 0,75 mm2 2 x 10 x 0,75 mm2 3 x 10 x 0,75 mm2

Fuse / Type A 63 A / C 80 A / C 100 A / CCurrent – nominal A 2 x 18 2 x 20,8 3 x 20,8Current – maximal A 2 x 36,3 2 x 35,9 3 x 35,9Softstart / 2 x MCD201 2 x MCD201 3 x MCD201Starting current A 2 x 47,52 2 x 54,91 3 x 54,91Type of refrigerant / R407C R407C R407CVolume of refrigerant kg 2 x 12,5 2 x 14 3 x 14Type of expansion valve / EEV EEV EEVType of compressor / Copeland SCROLL ZH Copeland SCROLL EVI Copeland SCROLL EVINumber of compressors / 2 2 3Circulating pumps - return flow / no no noFan type / Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN OwletBack-up electrical flow heater / no no no3-way diverting valve / no no noSerial integrated controller / Siemens RVS 21 Siemens RVS 21 Siemens RVS 21Control of mixing heating cirquit / with extension module with extension module with extension moduleControl of direct heating cirquit / with extension module with extension module with extension moduleSolar system control / with extension module with extension module with extension moduleModBus / with extension module with extension module with extension moduleWebControl / with WebServer module with WebServer module with WebServer moduleOption for cascade system / Yes (with LPB module) Yes (with LPB module) Yes (with LPB module)

Sp

lit s

yste

m a

ir /

wat

er :

out

do

or

un

it +

ind

oo

r u

nit

AE

RO

GO

R S

PL

IT H

D W

an

d S

PL

IT E

VI H

D W

23

Page 24: High power heat pumps catalogue en 2014 pdf

Model name Basic solution:Aerogor Compact 25 W +

DisplayBox WAerogor Compact 36 W +

DisplayBox WAerogor Compact 44 W +

DisplayBox WAerogor Compact 54 W +

DisplayBox WAerogor Compact EVI 27 W +

DisplayBox WOperating modes Heating / Cooling Heating / Cooling Heating / Cooling Heating / Cooling Heating / Cooling

Model name Advanced solution: Aerogor Compact 25 W +

ControlBox WAerogor Compact 36 W +

ControlBox WAerogor Compact 44 W +

ControlBox WAerogor Compact 54 W +

ControlBox WAerogor Compact EVI 27 W +

ControlBox WOperating modes Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHWCode numbers - Aerogor Compact W 432865 452269 452270 452291 452292Code numbers - DisplayBox W 477970 477970 477970 477970 477970Code numbers - ControlBox W 452714 452714 452714 452714 452714Connection between outdoor unit and heating system water pipe connection water pipe connection water pipe connection water pipe connection water pipe connectionHeating capacity A7/W35 kW 25,31 35,77 44,41 53,83 25,90COP A7/W35 / 4,64 4,77 4,64 4,77 4,79Heating capacity A7/W45 kW 24,30 34,35 42,65 51,70 26,20COP A7/W45 / 3,69 3,79 3,69 3,79 3,93Heating capacity A7/W55 kW 22,95 32,43 40,27 48,82 26,68COP A7/W55 / 2,92 3,00 2,92 3,00 3,23Heating capacity A7/W65 kW / / / / 26,78COP A7/W65 / / / / / 2,65Heating capacity A2/W35 kW 20,59 29,10 36,13 43,80 22,20COP A2/W35 / 3,60 3,70 3,60 3,70 3,70Heating capacity A2/W45 kW 19,79 27,97 34,73 42,10 22,36COP A2/W45 / 2,93 3,70 2,93 3,70 3,04Heating capacity A2/W55 kW 18,81 26,58 33,00 40,00 22,62COP A2/W55 / 2,33 2,39 2,33 2,39 2,49Heating capacity A2/W65 kW / / / / 22,86COP A2/W65 / / / / / 2,05Heating capacity A-2/W35 kW 17,30 24,45 30,36 36,80 20,54COP A-2/W35 / 3,23 3,32 3,23 3,32 3,35Heating capacity A-7/W35 kW 14,53 20,45 25,50 30,92 19,14COP A-7/W35 / 2,98 3,06 2,98 3,06 3,01Heating capacity A-15/W35 kW 11,82 16,71 20,75 25,15 15,93COP A-15/W35 / 2,39 2,45 2,39 2,45 2,52Maximum outlet water temperature °C 60 60 60 60 65Operating range °C -20°C to +40°C -20°C to +40°C -20°C to +40°C -20°C to +40°C -20°C to +40°CActive cooling / yes yes yes yes yesCooling capacity - reversible operation A35/W12 kW 16,50 23,30 28,20 34,20 18,60Power input - reversible operation A35/W12 kW 7,10 10,10 12,80 15,50 8,00ERR / 2,3 2,3 2,2 2,2 2,3Neto weight - outdoor unit kg 290 350 350 350 350Neto weight - indoor unit kg 27 27 27 27 27Dimensions of outdoor unit (W x D x H) mm 1345 x 930 x 943 1776 x 1371 x 1246 1776 x 1371 x 1246 1776 x 1371 x 1246 1776 x 1371 x 1246Dimensions of indoor unit (W x D x H) mm 535 x 350 x 590 535 x 350 x 590 535 x 350 x 590 535 x 350 x 590 535 x 350 x 590Voltage V/Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 HzNoise emissions [5m] - indoor unit dB 0 0 0 0 0Noise emissions [8m] - outdoor unit dB 58 61 61 66 58Connecting dimensions – secondary side ” 1 1/4 1 1/2 1 1/2 1 1/2 1 1/4Type of screw thread - outdoor unit / inner inner inner inner innerAir flow - primary side m3/h 4959 5800 10000 14067 10300Nominal water flow - secondary side m3/h 3,20 4,60 4,10 5,10 3,90Pressure drop - primary side kPa 0,05 0,057 0,043 0,061 0,057Pressure drop - secondary side kPa max 20 max 20 max 20 max 20 max 20Recommended temperature difference (flow / return) K 5 5 7 7 5Main connection cable – dimension mm2 5 x 6 mm2 5 x 6 mm2 5 x 6 mm2 5 x 10 mm2 5 x 6 mm2

Power connection (indoor - outdoor unit) mm2 5 x 6 mm2 5 x 6 mm2 5 x 6 mm2 5 x 10 mm2 5 x 6 mm2

Electrical connection cable between indoor - outdoor unit [sheathed] mm2 UTP & 5 x 0,75 mm2 UTP & 5 x 0,75 mm2 UTP & 5 x 0,75 mm2 UTP & 5 x 0,75 mm2 UTP & 5 x 0,75 mm2

Fuse / Type A 32 A / C 25 A / C 32 A / C 40 A / C 32 A / CCurrent – nominal A 11,60 11,80 16,80 18,00 11,80Current – maximal A 27,90 23,90 28,90 36,30 29,90Softstart / MCI 25 MCI 25 MCD201 MCD201 MCI 25Starting current A 30,62 31,15 44,35 47,52 31,15Type of refrigerant / R407C R407C R407C R407C R407CVolume of refrigerant kg 7,00 7,30 12,00 12,50 8,20Type of expansion valve / EEV EEV EEV EEV EEVType of compressor / Copeland SCROLL ZH Copeland SCROLL ZH Copeland SCROLL ZH Copeland SCROLL ZH Copeland SCROLL EVINumber of compressors / 1 1 1 1 1Circulating pumps - return flow / yes yes yes yes yesFan type / Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN OwletBack-up electrical flow heater / no no no no no3-way diverting valve / no no no no noSerial integrated controller / Siemens RVS 21 Siemens RVS 21 Siemens RVS 21 Siemens RVS 21 Siemens RVS 21Control of mixing heating cirquit / with extension module with extension module with extension module with extension module with extension moduleControl of direct heating cirquit / yes yes yes yes yesSolar system control / with extension module with extension module with extension module with extension module with extension moduleModBus / with extension module with extension module with extension module with extension module with extension moduleWebControl / with WebServer module with WebServer module with WebServer module with WebServer module with WebServer moduleOption for cascade system / Yes (with LPB module) Yes (with LPB module) Yes (with LPB module) Yes (with LPB module) Yes (with LPB module)

Syst

em a

ir /

wat

er -

Co

mp

act

out

do

or

un

itA

ER

OG

OR

CO

MPA

CT

W +

Dis

pla

yBox

W /

Co

ntro

lBox

W

24

Page 25: High power heat pumps catalogue en 2014 pdf

Model name Basic solution:Aerogor Compact EVI 37 W +

DisplayBox WAerogor Compact EVI 48 W +

DisplayBox WAerogor Compact EVI 56 W +

DisplayBox WOperating modes Heating / Cooling Heating / Cooling Heating / Cooling

Model name Advanced solution: Aerogor Compact EVI 37 W +

ControlBox WAerogor Compact EVI 48 W +

ControlBox WAerogor Compact EVI 56 W +

ControlBox WOperating modes Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHWCode numbers - Aerogor Compact W 452293 452294 452296Code numbers - DisplayBox W 477970 477970 477970Code numbers - ControlBox W 452714 452714 452714Connection between outdoor unit and heating system water pipe connection water pipe connection water pipe connectionHeating capacity A7/W35 kW 35,58 47,13 54,95COP A7/W35 / 4,79 4,91 4,91Heating capacity A7/W45 kW 36,00 47,68 55,59COP A7/W45 / 3,93 4,04 4,04Heating capacity A7/W55 kW 36,66 48,56 56,61COP A7/W55 / 3,23 3,31 3,31Heating capacity A7/W65 kW 36,80 48,74 56,83COP A7/W65 / 2,65 2,72 2,72Heating capacity A2/W35 kW 30,50 40,40 47,10COP A2/W35 / 3,70 3,80 3,80Heating capacity A2/W45 kW 30,72 40,69 47,44COP A2/W45 / 30,40 3,12 3,12Heating capacity A2/W55 kW 31,08 41,17 48,00COP A2/W55 / 2,49 2,56 2,56Heating capacity A2/W65 kW 31,41 41,61 48,51COP A2/W65 / 2,05 2,10 2,10Heating capacity A-2/W35 kW 28,23 37,39 43,59COP A-2/W35 / 3,35 3,44 3,44Heating capacity A-7/W35 kW 26,30 34,84 40,62COP A-7/W35 / 3,01 3,09 3,09Heating capacity A-15/W35 kW 21,88 28,98 33,79COP A-15/W35 / 2,52 2,59 2,59Maximum outlet water temperature °C 65 65 65Operating range °C -20°C to +40°C -20°C to +40°C -20°C to +40°CActive cooling / yes yes yesCooling capacity - reversible operation A35/W12 kW 23,90 31,80 36,80Power input - reversible operation A35/W12 kW 10,80 13,80 16,70ERR / 2,2 2,3 2,2Neto weight - outdoor unit kg 380 380 390Neto weight - indoor unit kg 27 27 27Dimensions of outdoor unit (W x D x H) mm 1776 x 1371 x 1246 1776 x 1371 x 1246 1776 x 1371 x 1246Dimensions of indoor unit (W x D x H) mm 535 x 350 x 590 535 x 350 x 590 535 x 350 x 590Voltage V/Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 HzNoise emissions [5m] - indoor unit dB 0 0 0Noise emissions [8m] - outdoor unit dB 61 66 66Connecting dimensions – secondary side ” 1 1/2 1 1/2 1 1/2Type of screw thread - outdoor unit / inner inner innerAir flow - primary side m3/h 10300 14067 14067Nominal water flow - secondary side m3/h 5,20 4,80 5,70Pressure drop - primary side kPa 0,075 0,043 0,061Pressure drop - secondary side kPa max 20 max 20 max 20Recommended temperature difference (flow / return) K 5 7 7Main connection cable – dimension mm2 5 x 6 mm2 5 x 10 mm2 5 x 10 mm2

Power connection (indoor - outdoor unit) mm2 5 x 6 mm2 5 x 10 mm2 5 x 10 mm2

Electrical connection cable between indoor - outdoor unit [sheathed] mm2 UTP & 5 x 0,75 mm2 UTP & 5 x 0,75 mm2 UTP & 5 x 0,75 mm2

Fuse / Type A 32 A / C 32 A / C 40 A / CCurrent – nominal A 14,60 16,80 20,80Current – maximal A 27,10 30,60 35,90Softstart / MCI 25 MCD201 MCD201Starting current A 38,54 44,35 51,91Type of refrigerant / R407C R407C R407CVolume of refrigerant kg 9,50 13,00 14,00Type of expansion valve / EEV EEV EEVType of compressor / Copeland SCROLL EVI Copeland SCROLL EVI Copeland SCROLL EVINumber of compressors / 1 1 1Circulating pumps - return flow / yes yes yesFan type / Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN OwletBack-up electrical flow heater / no no no3-way diverting valve / no no noSerial integrated controller / Siemens RVS 21 Siemens RVS 21 Siemens RVS 21Control of mixing heating cirquit / with extension module with extension module with extension moduleControl of direct heating cirquit / yes yes yesSolar system control / with extension module with extension module with extension moduleModBus / with extension module with extension module with extension moduleWebControl / with WebServer module with WebServer module with WebServer moduleOption for cascade system / Yes (with LPB module) Yes (with LPB module) Yes (with LPB module)

Syst

em a

ir /

wat

er -

Co

mp

act

out

do

or

un

itA

ER

OG

OR

CO

MPA

CT

W +

Dis

pla

yBox

W /

Co

ntro

lBox

W

25

Page 26: High power heat pumps catalogue en 2014 pdf

Sp

lit s

yste

m a

ir /

wat

er :

out

do

or

un

it +

ind

oo

r u

nit

AE

RO

GO

R S

PL

IT A

W W

an

d S

PL

IT A

W E

VI W

Model name Aerogor Split AW 25 W Aerogor Split AW 36 W Aerogor Split AW 44 W Aerogor Split AW 54 W Aerogor Split AW 47 EVI W Aerogor Split AW 55 EVI W

Operating modes Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHWCode number 461562 / 455397 453966 / 477703 468624 / 477704 468624 / 477705 468624 / 477706 468624 / 468630Connection between outdoor and indoor unit Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connectionHeating capacity A7/W35 kW 25,31 35,77 44,41 53,83 47,13 54,95COP A7/W35 / 4,64 4,77 4,64 4,77 4,91 4,91Heating capacity A7/W45 kW 24,30 34,35 42,65 51,70 47,68 55,59COP A7/W45 / 3,69 3,79 3,69 3,79 4,04 4,04Heating capacity A7/W55 kW 22,95 32,43 40,27 48,83 48,56 56,61COP A7/W55 / 2,92 3,00 2,92 3,00 3,31 3,31Heating capacity A7/W65 kW / / / / 48,74 56,83COP A7/W65 / / / / / 2,72 2,72Heating capacity A2/W35 kW 20,59 29,10 36,13 43,80 40,40 47,10COP A2/W35 / 3,60 3,70 3,60 3,70 3,80 3,80Heating capacity A2/W45 kW 19,79 27,97 34,73 42,10 40,69 47,44COP A2/W45 / 2,93 3,02 2,93 3,02 3,12 3,12Heating capacity A2/W55 kW 18,81 26,58 33,00 40,00 41,17 48,00COP A2/W55 / 2,33 2,39 2,33 2,39 2,56 2,56Heating capacity A2/W65 kW / / / / 41,61 48,51COP A2/W65 / / / / / 2,10 2,10Heating capacity A-2/W35 kW 17,30 24,45 30,36 36,80 37,39 43,59COP A-2/W35 / 3,23 3,32 3,23 3,32 3,44 3,44Heating capacity A-7/W35 kW 14,53 20,54 25,50 30,92 34,84 40,62COP A-7/W35 / 2,98 3,06 2,98 3,06 3,09 3,09Heating capacity A-15/W35 kW 11,82 16,71 20,75 25,15 28,98 33,79COP A-15/W35 / 2,39 2,45 2,39 2,45 2,59 2,59Maximum outlet water temperature °C 60 60 60 60 65 65Operating range °C -20°C to +40°C -20°C to +40°C -20°C to +40°C -20°C to +40°C -20°C to +40°C -20°C to +40°CActive cooling / yes yes yes yes yes yesCooling capacity - reversible operation A35/W12 kW 16,5 23,3 28,2 34,2 31,8 36,8Power input - reversible operation A35/W12 kW 7,1 10,1 12,8 15,5 13,8 16,7ERR / 2,3 2,3 2,2 2,2 2,3 2,2Neto weight - outdoor unit kg 149 170 175 198 210 210Neto weight - indoor unit kg 142 155 185 185 185 185Dimensions of outdoor unit (W x D x H) mm 800 x 580 x 1105 800 x 580 x 1105 800 x 785 x 1105 800 x 785 x 1105 800 x 785 x 1105 800 x 785 x 1105Dimensions of indoor unit (W x D x H) mm 800 x 900 x 775 1200 x 1290 x 1045 1200 x 1290 x 1045 1200 x 1290 x 1045 1200 x 1290 x 1045 1200 x 1290 x 1045Voltage V/Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 HzNoise emissions [5m] - indoor unit dB 52 54 55 57 55 57Noise emissions [8m] - outdoor unit dB 54 59 59 64 64 64Connecting dimensions – primary side mm 16 mm / 28 mm 18 mm / 28 mm 18 mm / 35 mm 22 mm / 35 mm 18mm / 35mm 22 mm / 35 mmConnecting dimensions – secondary side ” 1 1/4” 1 1/2” 1 1/2” 1 1/2” 1 1/2” 1 1/2”Type of screw thread - outdoor unit / inner inner inner inner inner innerAir flow - primary side m3/h 4959 5800 10.000 14.067 14067 14067Nominal water flow - secondary side m3/h 3,2 4,6 4,1 5,1 4,8 5,7Pressure drop - primary side kPa 0,05 0,057 0,043 0,061 0,043 0,061Pressure drop - secondary side kPa max 20 max 20 max 20 max 20 max 20 max 20Recommended temperature difference (flow / return) K 5 5 7 7 7 7Main connection cable – dimension mm2 5 x 6 mm2 5 x 6 mm2 5 x 6 mm2 5 x 10 mm2 5 x 10 mm2 5 x 10 mm2

Power connection (indoor - outdoor unit) mm2 3 x 1,5 mm2 3 x 1,5 mm2 3 x 1,5 mm2 3 x 1,5 mm2 3 x 1,5 mm2 3 x 1,5 mm2

Electrical connection cable between indoor - outdoor unit [sheathed] mm2 10 x 0,75 mm2 10 x 0,75 mm2 10 x 0,75 mm2 10 x 0,75 mm2 10 x 0,75 mm2 10 x 0,75 mm2

Fuse / Type A 32 A / C 25 A / C 32 A / C 40 A / C 32 A / C 40 A / CCurrent – nominal A 11,6 11,8 16,8 18 16,8 20,8Current – maximal A 27,9 23,9 28,9 36,3 30,6 35,9Softstart / MCI 25 MCI 25 MCD201 MCD201 MCD201 MCD201Starting current A 30,62 31,15 44,35 47,52 44,35 54,91Type of refrigerant / R407C R407C R407C R407C R407C R407CVolume of refrigerant kg 7 7,3 12 12,5 13 14Type of expansion valve / EEV EEV EEV EEV EEV EEVType of compressor / Copeland SCROLL ZH Copeland SCROLL ZH Copeland SCROLL ZH Copeland SCROLL ZH Copeland SCROLL EVI Copeland SCROLL EVINumber of compressors / 1 1 1 1 1 1Circulating pumps - return flow / yes yes yes yes yes yesFan type / Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN OwletBack-up electrical flow heater / no no no no no no3-way diverting valve / no no no no no noSerial integrated controller / Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Siemens RVS 61Control of mixing heating cirquit / yes yes yes yes yes yesControl of direct heating cirquit / yes yes yes yes yes yesSolar system control / yes yes yes yes yes yesModBus / with extension module with extension module with extension module with extension module with extension module with extension moduleWebControl / z Web modulom z Web modulom z Web modulom z Web modulom with WebServer module with WebServer moduleOption for cascade system / Yes (with LPB module) Yes (with LPB module) Yes (with LPB module) Yes (with LPB module) Yes (with LPB module) Yes (with LPB module)26

Page 27: High power heat pumps catalogue en 2014 pdf

Sp

lit s

yste

m a

ir /

wat

er :

out

do

or

un

it +

ind

oo

r u

nit

AE

RO

GO

R S

PL

IT A

W W

an

d S

PL

IT A

W E

VI W

Model name Aerogor Split AW 20 EVI W Aerogor Split AW 26 EVI W Aerogor Split AW 36 EVI W Aerogor Split AW 47 EVI W Aerogor Split AW 55 EVI W

Operating modes Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHWCode number 461562 / 461561 453966 / 472083 453966 / 453965 468624 / 477706 468624 / 468630Connection between outdoor and indoor unit Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connection Refrigerant pipe connectionHeating capacity A7/W35 kW 19,95 25,90 35,58 47,13 54,95COP A7/W35 / 4,91 4,79 4,79 4,91 4,91Heating capacity A7/W45 kW 20,18 26,20 36,00 47,68 55,59COP A7/W45 / 4,04 3,93 3,93 4,04 4,04Heating capacity A7/W55 kW 20,55 26,68 36,66 48,56 56,61COP A7/W55 / 3,31 3,23 3,23 3,31 3,31Heating capacity A7/W65 kW 20,63 26,78 36,80 48,74 56,83COP A7/W65 / 2,72 2,65 2,65 2,72 2,72Heating capacity A2/W35 kW 17,10 22,20 30,50 40,40 47,10COP A2/W35 / 3,80 3,70 3,70 3,80 3,80Heating capacity A2/W45 kW 17,22 22,36 30,72 40,69 47,44COP A2/W45 / 3,12 3,04 3,04 3,12 3,12Heating capacity A2/W55 kW 17,43 22,62 31,08 41,17 48,00COP A2/W55 / 2,56 2,49 2,49 2,56 2,56Heating capacity A2/W65 kW 17,61 22,86 31,41 41,61 48,51COP A2/W65 / 2,10 2,05 2,05 2,10 2,10Heating capacity A-2/W35 kW 15,82 20,54 28,23 37,39 43,59COP A-2/W35 / 3,44 3,35 3,35 3,44 3,44Heating capacity A-7/W35 kW 14,75 19,14 26,30 34,84 40,62COP A-7/W35 / 3,09 3,01 3,01 3,09 3,09Heating capacity A-15/W35 kW 12,27 15,93 21,88 28,98 33,79COP A-15/W35 / 2,59 2,52 2,52 2,59 2,59Maximum outlet water temperature °C 65 65 65 65 65Operating range °C -20°C to +40°C -20°C to +40°C -20°C to +40°C -20°C to +40°C -20°C to +40°CActive cooling / yes yes yes yes yesCooling capacity - reversible operation A35/W12 kW 14,6 18,6 23,9 31,8 36,8Power input - reversible operation A35/W12 kW 6,6 8 10,8 13,8 16,7ERR / 2,2 2,3 2,2 2,3 2,2Neto weight - outdoor unit kg 145 185 195 210 210Neto weight - indoor unit kg 142 155 155 185 185Dimensions of outdoor unit (W x D x H) mm 600 x 580 x 1105 800 x 580 x 1105 800 x 580 x 1105 800 x 785 x 1105 800 x 785 x 1105Dimensions of indoor unit (W x D x H) mm 800 x 900 x 775 1200 x 1290 x 1045 1200 x 1290 x 1045 1200 x 1290 x 1045 1200 x 1290 x 1045Voltage V/Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 HzNoise emissions [5m] - indoor unit dB 48 49 53 55 57Noise emissions [8m] - outdoor unit dB 54 59 59 64 64Connecting dimensions – primary side mm 12 mm / 22 mm 16 mm / 28 mm 16mm / 28mm 18mm / 35mm 22 mm / 35 mmConnecting dimensions – secondary side ” 1 1/4” 1 1/4” 1 1/2” 1 1/2” 1 1/2”Type of screw thread - outdoor unit / inner inner inner inner innerAir flow - primary side m3/h 4959 10.300 10.300 14067 14067Nominal water flow - secondary side m3/h 3 3,9 5,2 4,8 5,7Pressure drop - primary side kPa 0,05 0,057 0,075 0,043 0,061Pressure drop - secondary side kPa max 20 max 20 max 20 max 20 max 20Recommended temperature difference (flow / return) K 5 5 5 7 7Main connection cable – dimension mm2 5 x 4 mm2 5 x 6 mm2 5 x 6 mm2 5 x 10 mm2 5 x 10 mm2

Power connection (indoor - outdoor unit) mm2 3 x 1,5 mm2 3 x 1,5 mm2 3 x 1,5 mm2 3 x 1,5 mm2 3 x 1,5 mm2

Electrical connection cable between indoor - outdoor unit [sheathed] mm2 10 x 0,75 mm2 10 x 0,75 mm2 10 x 0,75 mm2 10 x 0,75 mm2 10 x 0,75 mm2

Fuse / Type A 25 A / C 32 A / C 32 A / C 32 A / C 40 A / CCurrent – nominal A 9,7 11,8 14,6 16,8 20,8Current – maximal A 25,5 29,9 27,1 30,6 35,9Softstart / MCI 15 MCI 25 MCI 25 MCD201 MCD201Starting current A 25,6 31,15 38,54 44,35 54,91Type of refrigerant / R407C R407C R407C R407C R407CVolume of refrigerant kg 5,9 8,2 9,5 13 14Type of expansion valve / 4.5 (12/16) EEV EEV EEV EEVType of compressor / Copeland SCROLL EVI Copeland SCROLL EVI Copeland SCROLL EVI Copeland SCROLL EVI Copeland SCROLL EVINumber of compressors / 1 1 1 1 1Circulating pumps - return flow / yes yes yes yes yesFan type / Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN Owlet Ziehl Abegg FN OwletBack-up electrical flow heater / yes, 3 x 2kW no no no no3-way diverting valve / yes no no no noSerial integrated controller / Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Siemens RVS 61Control of mixing heating cirquit / yes yes yes yes yesControl of direct heating cirquit / yes yes yes yes yesSolar system control / yes yes yes yes yesModBus / with extension module with extension module with extension module with extension module with extension moduleWebControl / with WebServer module with WebServer module with WebServer module with WebServer module with WebServer moduleOption for cascade system / Yes (with LPB module) Yes (with LPB module) Yes (with LPB module) Yes (with LPB module) Yes (with LPB module) 27

Page 28: High power heat pumps catalogue en 2014 pdf

Model name Terragor 28 WAquagor 37 W

Terragor 38 WAquagor 50 W

Terragor 43 WAquagor 59 W

Terragor 52 WAquagor 67 W

Terragor 56 WAquagor 78 W

Terragor 65 WAquagor 89 W

Operating modes Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW

Code number 477707 452305 477709 452306 477710 452297

Heating capacity B0/W35 kW 26,00 37,90 42,31 47,58 55,42 64,60

COP B0/W35 / 4,17 4,50 4,17 4,17 4,24 4,46

Heating capacity B0/W45 kW 24,63 33,67 40,09 45,08 52,50 60,06

COP B0/W45 / 3,32 3,38 3,32 3,32 3,38 3,38

Heating capacity B0/W55 kW 22,70 31,12 37,05 41,67 48,53 55,51

COP B0/W55 / 2,56 2,61 2,56 2,56 2,61 2,61

Heating capacity B0/W65 kW / / / / / /

COP B0/W65 / / / / / / /

Heating capacity W10/W35 kW 36,50 49,90 59,40 66,80 77,80 89,00

COP W10/W35 / 5,60 5,70 5,60 5,60 5,70 5,70

Heating capacity W10/W45 kW 34,50 47,17 56,15 63,14 73,54 84,12

COP W10/W45 / 4,44 4,52 4,44 4,44 4,52 4,52

Heating capacity W10/W55 kW 31,96 43,69 52,01 58,49 68,12 77,93

COP W10/W55 / 3,43 3,49 3,43 3,43 3,49 3,49

Heating capacity W10/W65 kW / / / / / /

COP W10/W65 / / / / / / /

Maximum outlet water temperature °C 60 60 60 60 60 60

Operating range of heat pumps brine - water °C –5 °C to +25°C –5 °C to +25°C –5 °C to +25°C –5 °C to +25°C –5 °C to +25°C –5 °C to +25°C

Operating range of heat pumps water - water °C +7°C to +25°C +7°C to +25°C +7°C to +25°C +7°C to +25°C +7°C to +25°C +7°C to +25°C

Pre-heat exchanger on primary side (for water-water system) / no no no no no no

Neto weight kg 248 264 311 355 368 386

Dimensions of indoor unit (W x D x H) mm 800 x 580 x 1105 1000 x 785 x 1105 1000 x 785 x 1105 1000 x 785 x 1105 1000 x 785 x 1105 1000 x 785 x 1105

Napetost V/Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz

Noise emissions [5m] - indoor unit dB 53 55 56 56 59 59

Connecting dimensions – primary side ˝ 1 1/2” 1 1/2” 2” 2” 2” 2”

Connecting dimensions – secondary side ˝ 1 1/4” 1 1/2” 2” 2” 2” 2”

Volume of flow - primary side m3/h 5,2 5,5 7,1 8,6 9,3 10,6

Nominal water flow - secondary side m3/h 4,8 4,2 5,3 6,4 6,9 7,8

Pressure drop - primary side kPa max 20 max 20 max 20 max 20 max 20 max 20

Pressure drop - secondary side kPa max 20 max 20 max 20 max 20 max 20 max 20

Recommended temperature difference (flow / return) - primary side K 5 7 7 7 7 7

Recommended temperature difference (flow / return) - secondary side K 5 5 5 5 5 5

Main connection cable – dimension mm2 5 x 6 mm2 5 x 6 mm2 5 x 6 mm2 5 x 10 mm2 5 x 10 mm2 5 x 16 mm2

Power connection cable mm2 5 x 1,5 mm2 5 x 1,5 mm2 5 x 1,5 mm2 5 x 2,5 mm2 5 x 2,5 mm2 5 x 2,5 mm2

Fuse / Type A 25 A / C 32 A / C 32 A / C 40 A / C 40 A / C 50 A / C

Current – nominal A 14,3 17,5 21 23,6 25,6 27,8

Current – maximal A 24 32 31,8 33,6 39,2 44,6

Softstart / 2 x MCI12 2 x MCI15 2 x MCI15 2 x MCI25 2 x MCI25 2 x MCI25

Starting current A 37,75 46,2 55,44 62,3 67,58 73,39

Type of refrigerant / R407C R407C R407C R407C R407C R407C

Volume of refrigerant kg 6,7 8,4 8,8 9,2 9,6 8,8

Type of compressor / TANDEM Copeland Scroll TANDEM Copeland Scroll TANDEM Copeland Scroll TANDEM Copeland Scroll TANDEM Copeland Scroll TANDEM Copeland Scroll

Number of compressors / 2 2 2 2 2 2

Circulating pumps - return flow / no no no no no no

Back-up electrical flow heater / no no no no no no

3-way diverting valve / no no no no no no

Control of mixing heating cirquit / yes yes yes yes yes yes

Control of direct heating cirquit / yes yes yes yes yes yes

Solar system control / yes yes yes yes yes yes

ModBus / with extension module with extension module with extension module with extension module with extension module with extension module

WebControl / with WebServer module with WebServer module with WebServer module with WebServer module with WebServer module with WebServer module

Serial integrated controller / Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Siemens RVS 61

Option for cascade system / yes yes yes yes yes yes

Type and material of heat exchanger - primary side /plate heat exchanger /

AISI 316plate heat exchanger /

AISI 316plate heat exchanger /

AISI 316plate heat exchanger /

AISI 316plate heat exchanger /

AISI 316plate heat exchanger /

AISI 316

Type and material of heat exchanger - secondary side /plate heat exchanger /

AISI 316plate heat exchanger /

AISI 316plate heat exchanger /

AISI 316plate heat exchanger /

AISI 316plate heat exchanger /

AISI 316plate heat exchanger /

AISI 316

Recommended water filter for heat pump water-water mcr 300 - 500 300 - 500 300 - 500 300 - 500 300 - 500 300 - 500

Syst

em b

rin

e-w

ater

an

d w

ater

-wat

erTE

RR

AG

OR

W -

AQ

UA

GO

R W

and

TER

RA

GO

R -

AQ

UA

GO

R E

VI W

28

Page 29: High power heat pumps catalogue en 2014 pdf

Model name Terragor 70 WAquagor 100 W

Terragor 83 WAquagor 115 W

Terragor EVI 37 WAquagor EVI 48 W

Terragor EVI 67 WAquagor EVI 87 W

Terragor EVI 81 WAquagor EVI 105 W

Terragor EVI 98 WAquagor EVI 126 W

Operating modes Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW Heating / Cooling / DHW

Code number 477711 452298 452299 452300 477712 452302

Heating capacity B0/W35 kW 70,52 83,20 37,45 67,17 81,24 98,05

COP B0/W35 / 4,17 4,35 4,50 4,50 4,50 4,40

Heating capacity B0/W45 kW 66,81 77,47 37,90 67,98 82,21 99,23

COP B0/W45 / 3,32 3,26 3,70 3,70 3,70 3,62

Heating capacity B0/W55 kW 61,75 71,60 38,50 69,05 83,51 100,80

COP B0/W55 / 2,56 2,51 2,96 2,96 2,96 2,89

Heating capacity B0/W65 kW / / 39,10 70,13 84,81 102,36

COP B0/W65 / / / 2,53 2,53 2,53 2,47

Heating capacity W10/W35 kW 99,00 114,80 48,24 86,51 104,64 126,29

COP W10/W35 / 5,60 5,50 4,55 4,55 4,55 4,44

Heating capacity W10/W45 kW 93,58 108,51 50,18 90,01 108,86 131,39

COP W10/W45 / 4,44 4,36 4,56 4,56 4,56 4,46

Heating capacity W10/W55 kW 86,69 100,52 50,18 90,01 108,86 131,39

COP W10/W55 / 3,43 3,37 3,75 3,75 3,75 3,66

Heating capacity W10/W65 kW / / 49,88 89,47 108,21 130,60

COP W10/W65 / / / 3,12 3,12 3,12 3,06

Maximum outlet water temperature °C 60 60 65 65 65 65

Operating range of heat pumps brine - water °C –5 °C to +25°C –5 °C to +25°C –5 °C to +25°C –5 °C to +25°C –5 °C to +25°C –5 °C to +25°C

Operating range of heat pumps water - water °C +7°C to +25°C +7°C to +25°C +7°C to +25°C +7°C to +25°C +7°C to +25°C +7°C to +25°C

Pre-heat exchanger on primary side (for water-water system) / no no yes yes yes yes

Neto weight kg 415 438 265 325 348 368

Dimensions of indoor unit (W x D x H) mm 1000 x 785 x 1105 1000 x 785 x 1105 800 x 580 x 1105 1000 x 785 x 1105 1000 x 785 x 1105 1000 x 785 x 1105

Napetost V/Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz 3 x 400 / 50 Hz

Noise emissions [5m] - indoor unit dB 60 63 52 54 56 56

Connecting dimensions – primary side ˝ 2” 2” 2” 2” 2” 2”

Connecting dimensions – secondary side ˝ 2” 2” 1 1/2” 2” 2” 2”

Volume of flow - primary side m3/h 11,4 13,5 6,8 10,4 13,2 16

Nominal water flow - secondary side m3/h 8,5 10,1 6,1 7,7 9,7 11,7

Pressure drop - primary side kPa max 20 max 20 max 20 max 20 max 20 max 20

Pressure drop - secondary side kPa max 20 max 20 max 20 max 20 max 20 max 20

Recommended temperature difference (flow / return) - primary side K 7 7 5 7 7 7

Recommended temperature difference (flow / return) - secondary side K 5 5 5 5 5 5

Main connection cable – dimension mm2 5 x 16 mm2 5 x 25 mm2 5 x 6 mm2 5 x 10 mm2 5 x 16 mm2 5 x 16 mm2

Power connection cable mm2 5 x 2,5 mm2 5 x 2,5 mm2 5 x 1,5 mm2 5 x 2,5 mm2 5 x 2,5 mm2 5 x 2,5 mm2

Fuse / Type A 63 A / C 80 A / C 25 A / C 40 A / C 50 A / C 80 A / C

Current – nominal A 33 44,6 17,3 23,6 27,8 33

Current – maximal A 54 78 34 33,6 44,6 54

Softstart / 2 x MCD201 2 x MCD201 2 x MCI25 2 x MCD201 2 x MCD201

Starting current A 87,12 117,74 46,5 62,3 73,39 87,12

Type of refrigerant / R407C R407C R407C R407C R407C R407C

Volume of refrigerant kg 9,4 10,2 8,7 6,2 6,7 8,9

Type of compressor / TANDEM Copeland Scroll TANDEM Copeland Scroll TANDEM Copeland Scroll Copeland SCROLL EVI Copeland SCROLL EVI Copeland SCROLL EVI

Number of compressors / 2 2 2 2 2 2

Circulating pumps - return flow / no no no no no no

Back-up electrical flow heater / no no no no no no

3-way diverting valve / no no no no no no

Control of mixing heating cirquit / yes yes yes yes yes yes

Control of direct heating cirquit / yes yes yes yes yes yes

Solar system control / yes yes yes yes yes yes

ModBus / with extension module with extension module with extension module with extension module with extension module with extension module

WebControl / with WebServer module with WebServer module with WebServer module with WebServer module with WebServer module with WebServer module

Serial integrated controller / Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Siemens RVS 61 Siemens RVS 61

Option for cascade system / yes yes yes yes yes yes

Type and material of heat exchanger - primary side /plate heat exchanger /

AISI 316plate heat exchanger /

AISI 316plate heat exchanger /

AISI 304plate heat exchanger /

AISI 304plate heat exchanger /

AISI 304plate heat exchanger /

AISI 304

Type and material of heat exchanger - secondary side /plate heat exchanger /

AISI 316plate heat exchanger /

AISI 316plate heat exchanger /

AISI 316plate heat exchanger /

AISI 316plate heat exchanger /

AISI 316plate heat exchanger /

AISI 316

Recommended water filter for heat pump water-water mcr 300 - 500 300 - 500 300 - 500 300 - 500 300 - 500 300 - 500

Syst

em b

rin

e-w

ater

an

d w

ater

-wat

erTE

RR

AG

OR

W -

AQ

UA

GO

R W

and

TER

RA

GO

R -

AQ

UA

GO

R E

VI W

29