PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: www.ecrinternational.com This manual has been prepared for use with the appropriate Installation, Operation and Maintenance Manual. APPLICATION GUIDE FOR USE WITH HEATING ONLY & COMBI MODELS: MAH-125 MAC-150 DCC-150 DCB-125

Upload: others

Post on 21-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

PN 240011430 REV D, [09/01/2016]

Manufactured for:ECR International, Inc.

2201 Dwyer Avenue, Utica NY 13501web site: www.ecrinternational.com

This manual has been prepared for use with the appropriate Installation, Operation and Maintenance Manual.

APPLICATION GUIDEFOR USE WITH

HEATING ONLY&

COMBI

MODELS:

MAH-125 MAC-150 DCC-150 DCB-125

Page 2: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

2

TABLE OF CONTENTS

IMPORTANT SAFETY INFORMATION .....................................................................................................3

HEATING ONLY - HYDRONIC PIPING ...........................................................................................4Primary/Secondary, Zoned, With Zone Valves, (Optional) Indirect Tank ......................................................5Primary/Secondary, Zoned, WITH ZONE PUMPS, (Optional) Indirect Tank ...................................................6Primary/Secondary, Series Loop Pumping, (Optional) Indirect Tank ............................................................7

WIRING DIAGRAMS ...................................................................................................................8Heating Only Boiler No Indirect Tank .....................................................................................................9Heating Only Boiler With Indirect Tank And Sensor ..................................................................................9Zoned System, With Multiple Zone Valves, Without Indirect Tank .............................................................11Zoned System, With Multiple Zone Valves, With Indirect Tank And Sensor ................................................12Boiler With Multiple Zone Pumps, Without Indirect Tank (DHW) ..................................................................14Boiler With Multiple Zone Pumps, With Indirect Tank (DHW) ......................................................................15

COMBI- Hydronic Piping ............................................................................................................16 COMBI- ANTI-SCALD PIPING ..........................................................................................................17

Primary/Secondary, Zoned, With Zone Valves And System Pump .............................................................18Primary/Secondary, Zoned, With Zone Pumps .......................................................................................19Primary/Secondary, Series Loop Pumping .............................................................................................20

WIRING DIAGRAMS .................................................................................................................21 Combi Boiler Single Zone with System Supply Pump ..............................................................................21

Combi Boiler with Multi-Zone Valves ....................................................................................................22Combi Boiler with Multi-Zone , with Multi-Zone Pumps ...........................................................................23

Boiler Interface Relay for External Central Heating System Pump Operation ......................................... 24

Optional Equipment .....................................................................................................................26 Available pump head for central heating...............................................................................................26 Outdoor Air Sensor & Indirect Tank Sensor Data ...................................................................................27

Accessories .................................................................................................................................28

Outdoor Temperature Sensor Kit......................................................................................................... 28 Indirect Storage Tank Sensor Kit..........................................................................................................29

Heating Only Boiler - Wiring Diagram ............................................................................................. 30Combi Boiler - Wiring Diagram ...................................................................................................... 31Altitude Effects On Boiler Performance ............................................................................................ 32Solder Fittings Notice ...................................................................................................................33Manufacturer Recommendation - Strainer ................................................................................ 34Warning Primary/Secondary Closely Spaced Tees ............................................................................. 35Application Table - Indirect Tank Sizing ........................................................................................... 36 Low Water Cutoff Application .........................................................................................................37

PN 240011430 REV D, [09/01/2016]

Page 3: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

3

IMPORTANT SAFETY INFORMATION

CAUTIONIndicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

!

WARNINGIndicates a hazardous situation which, if not avoided, could result in death or serious injury.

!

DANGERIndicates a hazardous situation which, if not avoided, WILL result in death or serious injury.

!

This is the safety alert symbol. Symbol alerts you to potential personal injury hazards. Obey all safety messages following this symbol to avoid possible injury or death.

2. Become familiar with symbols identifyingpotential hazards.

1. GeneralBoiler installation shall be completed by qualified agency. See Installation, Operation & Maintenance Manual for additional information.

WARNINGFire, explosion, asphyxiation and electrical shock hazard. Improper installation could result in death or serious injury. Read this manual and understand all requirements before beginning installation.

!

3. Installation shall conform to requirements of authority having jurisdiction or in absence of such requirements:

• United States • National Fuel Gas Code, ANSI Z223.1/NFPA 54.

• National Electrical Code, NFPA 70.• Canada

• Natural Gas and Propane Installation Code, CAN/CSA B149.1.

• Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, CSA C22.1

4. Where required by authority having jurisdiction, installation shall conform to Standard for Controls and Safety Devices for Automatically Fired Boilers, ANSI/ASME CSD-1. Additional manual reset low water cutoff or high limit may be required.

5. Requirements for Commonwealth of Massachusetts: Boiler installation must conform to Commonwealth of Massachusetts code 248 CMR which includes but is not limited to:• Installation by licensed plumber or gas fitter.

PN 240011430 REV D, [09/01/2016]

Page 4: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

4

HEATING ONLY - HYDRONIC PIPINGPiping Legend

Quick Reference Chart - Heating Only Boiler

Hydronic Piping Description Page

Single Boiler Primary/Secondary, Zoned System, WITH ZONE VALVES, and Optional Indirect Tank (Fig. 1) 5

Single Boiler Primary/Secondary, Zoned, WITH ZONE PUMPS, and (Optional) Indirect Tank (Fig. 2) 6

Single Boiler Primary/Secondary Series Loop PUMPING and Optional Indirect Tank (Fig. 3) 7

Wiring Description PageHeating Only Boiler NO Indirect Tank, Single Zone ( Fig. 4) 9

Heating Only Boiler WITH Indirect Tank and Sensor, Single Zone ( Fig. 5) 9

Heating Only Boiler with Multiple Zone Valves, WITHOUT Indirect Tank ( Fig. 6) 11

Heating Only Boiler with Multiple ZONE VALVES, WITH Indirect Tank and Sensor ( Fig. 7) 12

Heating Only Boiler with Multiple ZONE PUMPS, WITHOUT Indirect Tank (DHW) ( Fig. 8) 14

Heating Only Boiler with Multiple ZONE PUMPS, WITH Indirect Tank (DHW) ( Fig. 9) 15

Application Tables For : Heating Only Boiler With Indirect Hot Water Tank 28

Piping installation, materials, and joining methods shall conform to requirements of authority having jurisdiction or in absence of such requirements:

• USA - National Fuel Gas Code, ANSI Z223.1/NFPA 54• Canada - Natural Gas and Propane Installation Code,

CAN/CSA B149.1Manufacturer requires all domestic hot water (DHW) installations use an anti-scald valve. Local codes may require additional equipment (expansion tank, relief valves, etc.) Select and size equipment to suit installation and meet code requirements.

Note

Illustrations are meant to show system piping concept only. Installer is responsible for all equipment and detailing required by authority having jurisdiction.

NoteArrange piping to prevent water dripping onto boiler.

PN 240011430 REV D, [09/01/2016]

Page 5: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

5

HEATING ONLY - HYDRONIC PIPINGFIGURE 1 - Primary/Secondary, Zoned, WITH ZONE VALVES, (Optional) Indirect Tank

T &

P Re

lief

Valv

e to

D

rain

Cold

W

ater

Su

pply

Opt

iona

l In

dire

ct

DHW

Tan

k

BOIL

ER

Cold

Wat

er

Supp

ly

1

Tank

Se

nsor

2CH

/Sy

stem

Pu

mp

* Ho

t W

ater

Su

pply

Te

mpe

red

112

” (3

05m

m)

Max

imum

Se

para

tion

2Li

mit

com

bine

d su

pply

and

ret

urn

pipe

leng

ths

to m

axim

um to

tal

linea

r le

ngth

of 2

0 ft.

(6.

1 m

) be

twee

n bo

iler

and

clos

ely

spac

ed

tees

, whe

n m

inim

um 3

/4”

NPT

pipe

si

ze is

use

d. L

inea

r le

ngth

may

be

incr

ease

d if

supp

ly a

nd r

etur

n pi

pe

size

is in

crea

sed

to li

mit

pres

sure

dr

op.

No

te

No

te

No

te*

Man

ufac

ture

r re

quire

s al

l dom

estic

ho

t wat

er (

DHW

) in

stal

latio

ns u

se

an a

nti-s

cald

val

ve.

Loca

l cod

es

may

req

uire

add

ition

al e

quip

men

t (e

xpan

sion

tank

, rel

ief v

alve

s,

etc.

) Se

lect

and

siz

e eq

uipm

ent

to s

uit i

nsta

llatio

n an

d m

eet c

ode

requ

irem

ents

.

No

teUs

e ex

tern

al p

ump

rela

y or

Arg

o Zo

ne

Cont

rol t

o in

terf

ace

syst

em p

ump

to b

oile

r.Se

e w

iring

Fig

ures

6 a

nd 7

.

S

PN 240011430 REV D, [09/01/2016]

Page 6: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

6

HEATING ONLY - HYDRONIC PIPING

FIGURE 2 - Primary/Secondary, Zoned, WITH ZONE PUMPS, (Optional) Indirect Tank

T &

P Re

lief

Valv

e to

D

rain

Cold

W

ater

Su

pply

Opt

iona

l In

dire

ct

DHW

Tan

k

BOIL

ER

Cold

Wat

er

Supp

lyZone

Pu

mp

Tank

Se

nsor

2

1

* Ho

t Wat

er

Supp

ly

(Tem

pere

d)

112

” (3

05m

m)

Max

imum

Se

para

tion

2Li

mit

com

bine

d su

pply

and

ret

urn

pipe

leng

ths

to m

axim

um to

tal

linea

r le

ngth

of 2

0 ft.

(6.

1 m

) be

twee

n bo

iler

and

clos

ely

spac

ed

tees

, whe

n m

inim

um 3

/4”

NPT

pipe

si

ze is

use

d. L

inea

r le

ngth

may

be

incr

ease

d if

supp

ly a

nd r

etur

n pi

pe

size

is in

crea

sed

to li

mit

pres

sure

dr

op.

No

te

No

te

No

te*

Man

ufac

ture

r re

quire

s al

l dom

estic

ho

t wat

er (

DHW

) in

stal

latio

ns u

se

an a

nti-s

cald

val

ve.

Loca

l cod

es

may

req

uire

add

ition

al e

quip

men

t (e

xpan

sion

tank

, rel

ief v

alve

s,

etc.

) Se

lect

and

siz

e eq

uipm

ent

to s

uit i

nsta

llatio

n an

d m

eet c

ode

requ

irem

ents

.

See

wiri

ng F

igur

es 8

and

9.

S

PN 240011430 REV D, [09/01/2016]

Page 7: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

7

Heating L

oad

Heating L

oad

FIGURE 3 - Primary/Secondary, Series Loop Pumping, (Optional) Indirect Tank

HEATING ONLY - HYDRONIC PIPING

T &

P Re

lief

Valv

e to

D

rain

Cold

W

ater

Su

pply

* Ho

t Wat

er

Supp

ly

(Tem

pere

d)

BOIL

ER

Cold

W

ater

Su

pply

Opt

iona

lIn

dire

ct

DHW

Tan

k

11

11

112

” (3

05m

m)

Max

imum

Se

para

tion

2Li

mit

com

bine

d su

pply

and

ret

urn

pipe

leng

ths

to m

axim

um to

tal

linea

r le

ngth

of 2

0 ft.

(6.

1 m

) be

twee

n bo

iler

and

clos

ely

spac

ed

tees

, whe

n m

inim

um 3

/4”

NPT

pipe

si

ze is

use

d. L

inea

r le

ngth

may

be

incr

ease

d if

supp

ly a

nd r

etur

n pi

pe

size

is in

crea

sed

to li

mit

pres

sure

dr

op.

No

te

No

te

No

te*

Man

ufac

ture

r re

quire

s al

l dom

estic

ho

t wat

er (

DHW

) in

stal

latio

ns u

se

an a

nti-s

cald

val

ve.

Loca

l cod

es

may

req

uire

add

ition

al e

quip

men

t (e

xpan

sion

tank

, rel

ief v

alve

s,

etc.

) Se

lect

and

siz

e eq

uipm

ent

to s

uit i

nsta

llatio

n an

d m

eet c

ode

requ

irem

ents

.

No

teUs

e ex

tern

al p

ump

rela

y an

d Ar

go Z

one

Cont

rol t

o in

terf

ace

syst

em p

ump

to b

oile

r.

CH S

yste

m

Pum

p

2

S

See

wiri

ng F

igur

es 8

, 9 a

nd 1

6.

Tank

Se

nsor

PN 240011430 REV D, [09/01/2016]

Page 8: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

8

Boiler Wiring DiagramsAll field wiring shall conform to the authority having jurisdiction or, in the absence of such requirements to:

USA: National Electrical Code, ANSI/NFPA 70, Canada: Canadian Electrical Code, Part I, CSA C22.1: Safety Standard for Electrical Installations.

A. Indirect Storage Tank is NOT used:• Connect M2 terminals #6 and #7 to Argo AR822 (T-T)

terminals.

• See Wiring Figures 4 and 16.

B. System Pump is used:• For Single Zone, Multi Zone and Series Loop Piping See

HEATING ONLY - WIRING DIAGRAMS

instructions and wiring diagrams. See Figures 4,5,6,7 and 16

C. Use of Indirect Storage Tank (DHW):

• Indirect storage tank, use only tank sensor to interface with boiler. Wire sensor to M2 terminals #9 and #10.

• Use of booster pump to increase flow rate to indirect tank is not recommended by manufacturer.

• Locate tank as close to boiler as possible. • Size DHW tank, piping, and system to use only internal

boiler pump.• See available pump head/flow rate chart, page 26 of

this manual. • Change PO3 parameter on boiler control from 08 to 05.

See Parameter Setting, in the Installation, Operation, and Maintenance Manual, Section 14.

• See Wiring Figure 5.

Note DO NOT use 120 V thermostat terminals (M1- #1 and #2).

DO NOT wire DHW mechanical thermostat to Argo Control or Heating Only Boiler control.

Use ONLY DHW Tank Sensor (M2- terminals #9 and #10).

Wiring Legend

Pump - Zone

Thermostat

Indirect Tank (DHW) Sensor

Valve - Zone

S

PN 240011430 REV D, [09/01/2016]

Page 9: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

9

FIGURE 4 - Heating Only Boiler NO Indirect Tank- Single Zone

HEATING ONLY - WIRING DIAGRAMS

FIGURE 5 - Heating Only Boiler WITH Indirect Tank and Sensor Single Zone

SUPPLY Cord 120V/60HZ

SUPPLY Cord 120V/60HZ

Change PO3 parameter on boiler control from 08 to 05

BOILER CONTROL

BOILER CONTROL

Wire to AR822 T-T TerminalsSee Figure 16

Wire to AR822 T-T TerminalsSee Figure 16

DHW Indirect Tank Sensor

Do Not Use

Do Not Use

PN 240011430 REV D, [09/01/2016]

Page 10: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

10

D. Multi-Zoned Valve System:

1. If only Central Heating is required on multi-zone valve application :• Connect Boiler call for heat contacts M2 (24 VAC)

terminals #6 and #7 to Argo Zone control X-X terminals.

• Zone thermostats and valves are wired to Argo Control.

• Central Heating (CH) system pump is wired to Argo Primary Pump terminals.

• See wiring Figure 6.

2. If DHW tank is applied to Multi-Zone Valve application - use Indirect Tank Sensor:

• Attach Indirect Tank sensor to boiler control M2 terminals #9 & #10. Boiler control will set priority for DHW operation.

• Wire Boiler call for heat contacts M2 (24 VAC) terminals #6 & #7 to Argo Zone control X-X Terminals.

• Zone thermostats and valves are wired to Argo Control.

• Central Heating (CH) system pump is wired to Argo Primary Pump terminals.

• Change PO3 parameter on boiler control from 08 to 05. See Parameter Setting, in the Installation, Operation, and Maintenance Manual, Section 14.

• See wiring Figure 7.

HEATING ONLY- WIRING DIAGRAM

NoteDO NOT use 120 V thermostat terminals (M1- #1 and #2) .

DO NOT wire DHW mechanical thermostat to Argo Control or Heating Only Boiler control.

Note Set Argo priority switch to OFF position.

PN 240011430 REV D, [09/01/2016]

Page 11: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

11

HEATING ONLY - WIRING DIAGRAMFIGURE 6 - Zoned System, with Multiple ZONE VALVES, WITHOUT Indirect Tank

DO NOT use 120V Thermostat Terminals M1 (#1 and #2).

BOILER CONTROL

Argo AZ- 4CP

Low Volt Room Thermostats

VALVE

Low Voltage Zone Valve(s)

SUPPLY CORD 120V/60HZ

Set Priority Switch “OFF”

For Central Heating Only

Lights

VALVE VALVE VALVECH/

System Pump

Do Not Use

120V/60Hz Power Supply

NL

PN 240011430 REV D, [09/01/2016]

Page 12: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

12

HEATING ONLY - WIRING DIAGRAM

Argo AZ- 4CP

Low Volt Room Thermostats

VALVE VALVE VALVE VALVE

Low Voltage Zone Valve(S)

Set Priority Switch“OFF”

Lights

FIGURE 7 - Zoned System, with Multiple ZONE VALVES, WITH Indirect Tank and Sensor

DO NOT use 120V Thermostat Terminals M1 (#1 and #2).

Change PO3 parameter on boiler control from 08 to 05

BOILER CONTROL

SUPPLY CORD 120V/60HZ

INDIRECT TANK SENSOR

CH/System Pump

S

Do Not Use

120V/60Hz Power Supply

NL

PN 240011430 REV D, [09/01/2016]

Page 13: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

13

HEATING ONLY - WIRING DIAGRAM

E. Multi-Zone Pump System Using Argo ARM Controller:

1 - If Indirect Storage Tank IS NOT applied to a multi-zoned piping system:

• Boiler thermostat contacts (M2 Terminals #6 and #7) are wired to Argo ARM Zone Pump Control Terminals (X-X)

• Zone thermostats and zone pumps are wired to ARGO Controller

• Priority Switch OFF• CH Heating only• See Wiring Figure 8

2 - If Indirect Storage Tank IS applied to multi-zoned pump piping assembly:

• Indirect storage tank sensor is used to regulate storage tank temperature. Wire sensor to M2 terminals #9 and #10.

• Use of booster pump to increase flow rate to indirect tank is not recommended by manufacturer.

• Locate tank close to boiler as possible and size DHW tank/piping/system to use only the internal boiler pump.

• See available pump/head/flow rate chart page 26 of this manual.

• DHW circuit is controlled by boiler control and is Priority heat demand.

• Set Argo priority switch “OFF”. Zone 1 priority IS NOT used.

• See wiring Figure 9

3 - If Series Loop Piping is applied:

Wire system pump to Argo AR822 Relay and interface with boiler M2 (terminals #6 and #7) and Argo ARM Zone Control. See wiring Figures 8, 9 and 16.

When using Indirect Storage Tank change PO3 parameter on boiler control from 08 to 05. See Parameter Setting, in the Installation, Operation, and Maintenance Manual, Section 14.

NoteDO NOT use 120 V thermostat terminals (M1- #1 and #2).

DO NOT wire DHW mechanical thermostat to Argo Control or Heating Only Boiler control.

Use ONLY DHW Tank Sensor (M2- terminals #9 and #10).

Note

PN 240011430 REV D, [09/01/2016]

Page 14: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

14

HEATING ONLY - WIRING DIAGRAM

Zone Pumps

DO NOT use 120V Thermostat Terminals M1 (#1 and #2).

Low VoltRoom Thermostats

BOILER CONTROL

Set Priority Switch“OFF”

High Voltage Power Supply120V/60Hz

SUPPLY CORD 120V/60HZ

Argo ARM Zone Pump Control

Tran

sform

er

24VA

C

Heating Only

FIGURE 8 - Boiler WITH MULTIPLE ZONE PUMPS, WITHOUT Indirect Tank (DHW)

Do Not Use

PN 240011430 REV D, [09/01/2016]

Page 15: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

15

HEATING ONLY - WIRING DIAGRAM

Zone Pumps

DO NOT use 120V Thermostat Terminals M1 (#1 and #2).

Change PO3 parameter on boiler control from 08 to 05

SUPPLY CORD 120V/60HZ

DHW INDIRECT TANK SENSOR

Low VoltRoom Thermostats

Set Priority Switch“OFF”

High Voltage Power Supply120V/60Hz

Argo ARM Zone Pump Control

Tran

sform

er

24VA

C

BOILER CONTROL

S

FIGURE 9 - Boiler WITH MULTIPLE ZONE PUMPS, WITH Indirect Tank (DHW)

Do Not Use

PN 240011430 REV D, [09/01/2016]

Page 16: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

16

COMBI- HYDRONIC PIPING

A. Piping installation, materials, and joining methods shall conform to requirements of authority having jurisdiction or in absence of such requirements:

• USA - National Fuel Gas Code, ANSI Z223.1/NFPA 54• Canada - Natural Gas and Propane Installation Code,

CAN/CSA B149.1B. Manufacturer requires all domestic hot water (DHW) installations use an anti-scald valve. Local codes may require additional equipment (expansion tank, relief valves, etc.) Select and size equipment to suit installation and meet code requirements.

Quick Reference Chart - Combi BoilerHydronic Piping Description Page

ANTI-SCALD WARNING AND PIPING RECOMMENDATION 17

Combi Primary/Secondary Zoned System WITH ZONE VALVES and System Pump (Fig. 10) 18

Combi Primary/Secondary Zoned WITH ZONE PUMPS (Fig. 11) 19

Combi Primary/Secondary Series Loop PUMPING (Fig. 12) 20

Wiring Description Page

Combi Boiler with System Supply Pump, Single Zone (Fig. 13) 21

Combi Boiler with Multiple Zone Valves (Fig. 14) 22

Combi Boiler with Multiple Zone Pumps (Fig. 15) 23

NoteArrange piping to prevent water dripping onto boiler.

PN 240011430 REV D, [09/01/2016]

Page 17: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

17

WARNINGBurn and scald hazard!

Manufacturer requires installation of field supplied anti-scald valve.

Failure to follow these instructions could result in death or serious injury.

!

COMBI - DHW ANTI-SCALD PIPING

Boiler

Cold Water Supply

Piping Legend

CH Return

HotWater Supply

(Tempered)

CH Supply

DHW Outlet

DHW Inlet

Tempering Valve

PN 240011430 REV D, [09/01/2016]

Page 18: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

18

COMBI - HYDRONIC PIPINGFIGURE 10 - Combi - Primary/Secondary, Zoned, WITH ZONE VALVES and System Pump

DH

W -

Col

d In

let

BOIL

ER

Cold

Wat

er

Supp

ly

1

* D

HW

- H

ot O

utle

t [S

ee p

age

17]

CH/S

yste

m

Pum

p2

112

” (3

05m

m)

Max

imum

Se

para

tion

2Li

mit

com

bine

d su

pply

and

ret

urn

pipe

leng

ths

to m

axim

um to

tal

linea

r le

ngth

of 2

0 ft.

(6.

1 m

) be

twee

n bo

iler

and

clos

ely

spac

ed

tees

, whe

n m

inim

um 3

/4”

NPT

pipe

si

ze is

use

d. L

inea

r le

ngth

may

be

incr

ease

d if

supp

ly a

nd r

etur

n pi

pe

size

is in

crea

sed

to li

mit

pres

sure

dr

op.

No

te

No

te

No

te*

Man

ufac

ture

r re

quire

s al

l dom

estic

ho

t wat

er (

DHW

) in

stal

latio

ns u

se

an a

nti-s

cald

val

ve.

Loca

l cod

es

may

req

uire

add

ition

al e

quip

men

t (e

xpan

sion

tank

, rel

ief v

alve

s,

etc.

) Se

lect

and

siz

e eq

uipm

ent

to s

uit i

nsta

llatio

n an

d m

eet c

ode

requ

irem

ents

.

See

wiri

ng F

igur

e 14

. Us

e w

ith e

xter

nal s

yste

m p

ump

rela

y or

Arg

o Zo

ne C

ontr

ol to

inte

rfac

e Sy

stem

Pum

p to

boi

ler.

PN 240011430 REV D, [09/01/2016]

Page 19: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

19

FIGURE 11 - Combi - Primary/Secondary, Zoned, WITH ZONE PUMPS

COMBI - HYDRONIC PIPING

DH

W -

Col

d In

let

BOIL

ER

Cold

W

ater

Su

pply

1

* D

HW

- H

ot O

utle

t [S

ee p

age

17]

Zone

Pum

p

2

112

” (3

05m

m)

Max

imum

Se

para

tion

2Li

mit

com

bine

d su

pply

and

ret

urn

pipe

leng

ths

to m

axim

um to

tal

linea

r le

ngth

of 2

0 ft.

(6.

1 m

) be

twee

n bo

iler

and

clos

ely

spac

ed

tees

, whe

n m

inim

um 3

/4”

NPT

pipe

si

ze is

use

d. L

inea

r le

ngth

may

be

incr

ease

d if

supp

ly a

nd r

etur

n pi

pe

size

is in

crea

sed

to li

mit

pres

sure

dr

op.

No

te

No

te

No

te*

Man

ufac

ture

r re

quire

s al

l dom

estic

ho

t wat

er (

DHW

) in

stal

latio

ns u

se

an a

nti-s

cald

val

ve.

Loca

l cod

es

may

req

uire

add

ition

al e

quip

men

t (e

xpan

sion

tank

, rel

ief v

alve

s,

etc.

) Se

lect

and

siz

e eq

uipm

ent

to s

uit i

nsta

llatio

n an

d m

eet c

ode

requ

irem

ents

.

See

wiri

ng F

igur

es 1

5 an

d 16

.

PN 240011430 REV D, [09/01/2016]

Page 20: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

20

COMBI - HYDRONIC PIPING

Heating L

oad

Heating L

oad

FIGURE 12 - Combi - Primary/Secondary, Series Loop PUMPING

DHW

- C

old

Inle

t

BOIL

ERCo

ld W

ater

Su

pply

*DHW

- H

ot O

utle

t [Se

e Pa

ge 1

7]

CH/S

yste

m

Pum

p

1

1 1

1

2

See

wiri

ng F

igur

es 1

5 an

d 16

. Us

e w

ith e

xter

nal s

yste

m p

ump

rela

y an

d Ar

go Z

one

Cont

rol t

o in

terf

ace

Syst

em P

ump

to b

oile

r Se

e pa

ge 2

5.

112

” (3

05m

m)

Max

imum

Sep

arat

ion

No

te

2N

ote

Lim

it co

mbi

ned

supp

ly a

nd r

etur

n pi

pe

leng

ths

to m

axim

um to

tal l

inea

r le

ngth

of

20 ft

. (6.

1 m

) be

twee

n bo

iler

and

clos

ely

spac

ed te

es, w

hen

min

imum

3/4

” NP

T pi

pe s

ize

is u

sed.

Lin

ear

leng

th m

ay b

e in

crea

sed

if su

pply

and

ret

urn

pipe

siz

e is

in

crea

sed

to li

mit

pres

sure

dro

p

No

te

* M

anuf

actu

rer

requ

ires

all d

omes

tic h

ot w

ater

(D

HW)

inst

alla

tions

use

an

anti-

scal

d va

lve.

Loc

al

code

s m

ay r

equi

re a

dditi

onal

equ

ipm

ent (

expa

nsio

n ta

nk, r

elie

f val

ves,

etc

.) S

elec

t and

siz

e eq

uipm

ent

to s

uit i

nsta

llatio

n an

d m

eet c

ode

requ

irem

ents

.

PN 240011430 REV D, [09/01/2016]

Page 21: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

21

COMBI BOILER - WIRING DIAGRAMS

1. Wiring DiagramsAll field wiring shall conform to the authority having jurisdiction or, in the absence of such requirements to:

USA: National Electrical Code, ANSI/NFPA 70, Canada: Canadian Electrical Code, Part I, CSA C22.1: Safety Standard for Electrical Installations. 2. Connect M2 terminals #6 and #7 to Argo AR822 (T-T) terminals. See Figure 13.

3. System Pump is Used:• For Single Zone piping use - External pump relay (AR822)

to interface central heating system pump operation with either Heating Only or Combi Boiler Control. See Figure 16.

• For Multi Zone Valve piping - Wire system pump to Argo AZ primary pump terminals. See Figure 14.

• Multi Zone Pump/Series Loop (Only) - see Piping Figure 16. External pump - Instruction and Wiring.

FIGURE 13 - Combi Boiler with System Supply Pump - Single Zone

Note

COMBI BOILER CONTROL

Do Not Use

DO NOT use 120 V thermostat terminals (M1- #1 and #2).

Connect to Argo AR822 (T-T)Terminals

Supply Cord 120V/60HZ

PN 240011430 REV D, [09/01/2016]

Page 22: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

22

COMBI BOILER - WIRING DIAGRAMS

FIGURE 14 - Combi Boiler with Multiple Zone Valves

4. Use of Multi-Zone Valve System Boiler call for heat contacts M2 terminals #6 and #7 are wired to Argo Zone Control (x-x) terminals. Zone thermostats and zone valves are wired to Argo Zone Controller. Connect CH/System Pump to Primary Pump terminals on Argo Control.See Figure 14.

Set Argo Priority Switch to OFF position. This disables priority operation and all zone valves will operate independently.

Refer to Argo Controller instructions for switch setting and operation information.

COMBI BOILER CONTROL

Note DO NOT Use 120 V thermostat terminals M1 (#1 and #2).

Do Not Use

Argo AZ - 4CPSET

PRIORITY TO OFF

SUPPLY CORD 120V/60HZ

LIGHTS

LOW VOLTAGE ZONE VALVESCH/System Pump

LOW VOLTAGE ROOM THERMOSTATS

120V/60Hz Power Supply

NL

PN 240011430 REV D, [09/01/2016]

Page 23: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

23

Argo ARM Zone Pump Control

POWER SUPPLY CORD 120V/60HZ

SET PRIORITY SWITCH TO

“OFF”Tran

sform

er

24VA

C

COMBI BOILER CONTROL

COMBI BOILER - WIRING DIAGRAMS

FIGURE 15 - Combi Boiler with Multiple Zone PUMPS

5. Use of Multi-Zone Pump System Boiler Thermostat contacts M2 terminals #6 and #7 are wired to Argo ARM Zone Pump Control terminals (x-x). Use Argo ARM Zone Pump Controller and wire as shown in Figure 15.

Note DO NOT Use 120 V thermostat terminals M1 (#1 and #2).

Do Not Use

ZONE PUMPS POWER SUPPLY 120V/60HZ

LOW VOLTAGE ROOM THERMOSTATS

PN 240011430 REV D, [09/01/2016]

Page 24: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

24

ADDITION OF AN EXTERNAL PUMP

INSTRUCTIONS AND WIRING DIAGRAM FOR ADDING EXTERNAL PUMP TO

HEATING ONLY AND COMBI BOILERS

1. Follow instructions to TURN OFF GAS TO APPLIANCE found on Operation Instructions label on boiler or in Installation, Operation & Maintenance Manual. Verify all electrical power to boiler is turned off.

WARNINGElectric shock hazard. Turn OFF electrical power supply at service panel.

!

2. Verify all power to boiler is turned OFF at service panel.3. Follow Installation, Operation & Maintenance manual to

remove front jacket panel(s).

WARNINGBurn hazard. Verify heat exchanger has cooled or use appropriate personal protection equipment.

!

4. Inspect combustion chamber through sight glass. Verify flame is not present.

5. See relay wiring attached.6. Resume operation using OPERATING INSTRUCTIONS

found on Operating Instructions label on boiler or in Installation, Operation & Maintenance Manual.

7. Verify proper operation by following START UP PROCEDURE in Installation, Operation & Maintenance Manual.

8. Follow Installation, Operation & Maintenance manual to install front jacket panel(s).

Installation shall be completed by qualified agency.

WARNINGFire, explosion, asphyxiation and electrical shock hazard. Improper installation could result in death or serious injury. Read this instruction and understand all requirements, including requirements of authority having jurisdiction, before beginning installation. Installation not complete until appliance operation verified per Installation, Operation & Maintenance Manual provided with boiler.

! For Single Zone Piping:External pump relay (AR-822) is required to interface Central Heating (CH) system supply pump operation with Heating Only or Combi Boiler Control.

See External Pump - Instruction and Wiring, Figure 16A or 16B.

For Multi-Zone Piping:

1. Connect CH/System supply pump to Argo AZ Control primary pump contacts.

2. For Multi Zone/Series Loop Piping, see Figures 3 and 12: Use Argo AR822 Control AND Argo ARM Zone Control to sequence system pump to zone pumps and boiler operation. See Figure 16C.

See : Heating Only Boiler - Wiring Figures 6 and 7Heating Only Boiler - Piping Figures 1 and 3.Combi Wiring - Figure 14Combi Boiler Piping - Figures 10 and 12.

PN 240011430 REV D, [09/01/2016]

Page 25: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

25

ADDITION OF AN EXTERNAL PUMP

FIGURE 16 - External Pump/Relay Wiring Diagram , Heating Only And Combi Boilers - Single Zone, And Wiring External System Pump for Series Loop /Multi Zone Piping

Com

bi B

oile

r

BO

ILER

CO

NTR

OL

M2

Term

inal

Str

ip

Transformer 15VAC

ARG

O C

ontr

olle

r

Transformer 15VAC

ARG

O C

ontr

olle

r

Hea

ting

Onl

y

BO

ILER

CO

NTR

OL

M2

Term

inal

Str

ip

Transformer 15VAC

ARG

O C

ontr

olle

r

A)

Sing

le Z

one

B) S

ingl

e Zo

neC)

Mul

ti Z

one

Call

For

Heat

Lo

w V

olta

geDH

W T

ank

Sens

or

if In

dire

ct T

ank

is u

sed

Fact

ory

Inst

alle

d Ju

mpe

r

D

O N

OT

REM

OVE

Exte

rnal

Sy

stem

Pum

p

----

---

Fiel

d In

stal

led

Wiri

ngAr

go c

onta

ct r

atin

g =

7 A

mp

Max

imumRE

LAY

Call

For

Hea

t Lo

w V

olta

ge

Fact

ory

Inst

alle

d Ju

mpe

r

D

O N

OT

REM

OV

E

Exte

rnal

Sy

stem

Pum

p

----

---

Fiel

d In

stal

led

Wirin

gArg

o co

ntac

t ra

ting

= 7

Am

p M

axim

um

REL

AY

Fact

ory

Inst

alle

d Ju

mpe

r

D

O N

OT

REM

OVE

Exte

rnal

Sy

stem

Pum

p

From

Arg

o AR

M

Zone

Pum

p Co

ntro

lTe

rmin

als

(x-x

)

Hea

tin

g O

nly

or

Com

bi

Boi

ler

Ser

ies

Loop

On

ly

----

---

Fiel

d In

stal

led

Wirin

gArg

o co

ntac

t ra

ting

= 7

Am

p M

axim

um

PN 240011430 REV D, [09/01/2016]

Page 26: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

26

AVAILABLE PUMP HEAD

Available Pump Head

Note The intended use of this pump is a boiler loop. Do not use as system pump.

PN 240011430 REV D, [09/01/2016]

Page 27: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

27

OPTIONAL EQUIPMENT

Optional Equipment1. Outdoor Air Sensor, if used.

A. Boiler automatically recognizes sensor when used.B. See Chart 1 for sensor data. Sensor part number BD710487302VC. Locate outdoor sensor to protect against wind and direct sunlight. Mounting instructions provided with sensor.D. Maximum wire length is 100 ft (30m) for 22 ga. wire, or 150 ft (45m) for 18 ga. wire.E. Connect wires to M2 OUTDOOR SENSOR terminals 4 & 5. Wires are interchangeable. See Accessories.

2. Sensor for Indirect DHW Tank (Heating Only Boiler).A. See Chart 2 for sensor data.

See Accessories section of this manual for wiring diagram.

CHART 1 - OUTDOOR AIR SENSOR DATAT R T R

[°F] [Ohm] [°F] [Ohm]-4.0 7,578 53.6 1,690

-2.2 7,193 55.4 1,621

-0.4 6,831 57.2 1,555

1.4 6,489 59.0 1,492

3.2 6,166 60.8 1,433

5.0 5,861 62.6 1,375

6.8 5,574 64.4 1,321

8.6 5,303 66.2 1,268

10.4 5,046 68.0 1,218

12.2 4,804 69.8 1,170

14.0 4,574 71.6 1,125

15.8 4,358 73.4 1,081

17.6 4,152 75.2 1,040

19.4 3,958 77.0 1,000

21.2 3,774 78.8 962

23.0 3,600 80.6 926

24.8 3,435 82.4 892

26.6 3,279 84.2 858

28.4 3,131 86.0 827

30.2 2,990 87.8 796

32.0 2,857 89.6 767

33.8 2,730 91.4 740

35.6 2,610 93.2 713

37.4 2,496 95.0 687

39.2 2,387 96.8 663

41.0 2,284 98.6 640

42.8 2,186 100.4 617

44.6 2,093 102.2 595

46.4 2,004 100.4 617

48.2 1,920 102.2 595

50.0 1,840 104.0 575

51.8 1,763 106.0 556

CHART 2 - INDIRECT TANK SENSOR DATAT R T R

[°F] [Ohm] [°F] [Ohm]32.0 32,505 86.0 8,060

33.8 30,898 87.8 7,726

35.6 29,381 89.6 7,407

37.4 27,946 91.4 7,103

39.2 26,590 93.2 6,813

41.0 25,308 95.0 6,537

42.8 24,094 96.8 6,273

44.6 22,946 98.6 6,021

46.4 21,859 100.4 5,781

48.2 20,829 102.2 5,551

50.0 19,854 104.0 5,332

51.8 18,930 105.8 5,123

53.6 18,054 107.6 4,923

55.4 17,223 109.4 4,732

57.2 16,436 111.2 4,549

59.0 15,689 113.0 4,374

60.8 14,980 114.8 4,207

62.6 14,306 116.6 4,047

64.4 13,667 118.4 3,894

66.2 13,060 120.2 3,748

68.0 12,483 122.0 3,608

69.8 11,935 123.8 3,473

71.6 11,414 125.6 3,345

73.4 10,919 127.4 3,222

75.2 10,447 129.2 3,104

77.0 9,999 131.0 2,991

78.8 9,572 132.8 2,882

80.6 9,166 134.6 2,778

82.4 8,779 136.4 2,679

84.2 8,411 138.2 2,583

PN 240011430 REV D, [09/01/2016]

Page 28: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

28

Accessories:

ACCESSORIES

1. Outdoor Temperature Sensor Kit - BD710487302VUse Outdoor Sensor Kit with Heating Only or Combi Boilers. Wire Control to boiler M2 terminal strip terminals #4 and #5 as shown below.Install/locate Control according to instructions supplied with sensor kit and Installation, Operation and Maintenance Manual (IOM).

Setting “Kt” Climate Curve:

Start boiler in CH mode. Depress CH control button once.

Boiler control will recognize installed OAS sensor. Display will change to show current default “Kt” value. Note display value.

When operation in CH mode, Kt value setting will over ride maximum CH boiler control set point based on current outdoor temperature.• Refer to applicable °F (or °C) chart,• Identify Kt range that will satisfy the desired boiler

delivery temperature based on average (extreme) outdoor temperature range expected for climate location.

Flow Temp Outside Temp

Boiler Control PanelNote

For temperatures below -40°F (-40°C), maximum heating flow temperature set point no longer increases and curves on the graph become horizontal.

°F°C

• Use lower value of range as the desired Kt value. (example): to deliver 186°F water @ OT of -20°F = Kt range is 90 thru 25. Select 25.

• To change”default” Kt value on boiler control use +/- CH Heating buttons.

When scolling has stopped, boiler will automatically “SAVE” value as new Kt defalt value and automatically return to CH mode when no Kt adjustment activity is sensed. Kt values can be changed in +/- 1 point increments.

To return to check or change current Kt “default value - depress one of the CH setpoint adjustment buttons (once), while in any heating or standby mode. Adjust Kt value to obtain desired comfort level.

PN 240011430 REV D, [09/01/2016]

Page 29: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

29

ACCESSORIES2. Indirect Storage Tank Sensor Kit

A Heating SystemB Three way diverter valveC Heating water flowD Heating supply to DHW indirect storage tank coilE Heating water returnF TankG DHW priority sensor tank

Heating Only boiler can be electrically connected to Indirect Storage Tank. Diagram of hydraulic connection of external indirect storage tank is shown below. Connect DHW priority sensor to terminals #9 and #10 on terminal block M2. The element of the sensor must be inserted in the sensor well located on the indirect storage tank. Make sure the exchange capacity of the storage boiler coil is appropriate for power of the boiler. Adjust DHW temperature (+95°F...+140°F / +35°C...+60°C) by pressing

buttons on boiler control panel.

Boiler Control Panel

Note Parameter PO3 for Heating Only boiler, with no indirect tank remains Factory Set at 08. No change is required.

If adding an Indirect Tank to Heating Only Boiler - change PO3 parameter from 08 to 05. See Section 14, Parameter Settings, in boiler’s Installation, Operation, and Maintenance Manual.

Parameter PO3 for COMBI boiler factory set at OO requires no change.

PN 240011430 REV D, [09/01/2016]

Page 30: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

30

HEATING ONLY BOILER - WIRING DIAGRAM1

Fuse

s

212

0 V

Pow

er S

uppl

y

4Fa

n

5Cen

tral

Hea

ting

Wat

er H

ighl

imit

6G

as V

alve

7N

TC E

xcha

nger

Flu

e Se

nsor

8W

ater

Pre

ssur

e Se

nsor

9H

eatin

g Re

turn

Sen

sor

10H

eatin

g Fl

ow S

enso

r

11N

TC F

lue

Sens

or

13O

utdo

or S

enso

r

1424

V Ro

om T

herm

ost

(RT)

15Bo

iler

NTC

DH

W S

enso

r

16Fl

ame

Sens

or E

lect

rode

17Ig

nitio

n El

ectr

ode

18D

iver

ter

Valv

e m

otor

19Pu

mp

20Ai

r Pr

essu

re S

witc

h

Bl

Blue

lBlig

ht B

lue

Br

Brow

n

Bk

Blac

k

RRe

d

G/Y

Yello

w/G

reen

GG

reen

WW

hite

Gr

Gre

y

YYe

llow

PN 240011430 REV D, [09/01/2016]

Page 31: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

31

COMBI BOILER - WIRING DIAGRAM1

Fuse

s

212

0 V

Pow

er S

uppl

y

312

0 V

Room

The

rmos

tat

(RT)

4Fa

n

5Ce

ntra

l Hea

ting

Wat

er H

ighl

imit

6G

asd

Valv

e

7D

HW

Prio

rity

Sens

or

8N

TC E

xcha

nger

Flu

e Se

nsor

9W

ater

Pre

ssur

e se

nsor

10H

eatin

g Re

turn

Sen

sor

11H

eatin

g Fl

ow S

enso

r

12N

TC F

lue

Sens

or

13Lo

w V

olta

ge C

onne

ctio

n

14O

utdo

or S

enso

r

1424

V Ro

om T

herm

ost

(RT)

16Fl

ame

Sens

or E

lect

rode

17Ig

nitio

n El

ectr

ode

18D

iver

ter

Valv

e m

otor

19Pu

mp

20Ai

r Pr

essu

re S

witc

h

21N

TC F

lue

Sens

or

Bl

Blue

lBlig

ht B

lue

Br

Brow

n

Bk

Blac

k

RRe

d

G/Y

Yello

w/G

reen

GG

reen

WW

hite

Gr

Gre

y

YYe

llow

PN 240011430 REV D, [09/01/2016]

Page 32: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

32

ALTITUDE EFFECTS ON BOILER PERFORMANCE

0

2000

0

4000

0

6000

0

8000

0

1000

00

1200

00

1400

00

1600

00

1800

00

020

00'

4500

'65

00'

9800

'

BOILER INPUT (BTUH) CA

LCUL

ATED

EFFE

CTS O

F HI-A

LTIT

UDE O

N BO

ILER

PERF

ORM

ANCE

DHW

MOD

E

HEAT

MOD

E

ALTI

TUDE

(FEE

T)

PN 240011430 REV D, [09/01/2016]

Page 33: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

33

FACTORY SUPPLIED TRIM NOTICE

Do not solder fittings when they are threaded onto boiler. Heating the boiler fittings will cause failure of the gaskets

and water leaks.

1. Use piping accessories as shown below. 2. Do any soldering away from the boiler, then thread soldered assembly to Boiler connections.

Factory Supplied Trim

The boiler features quick connection removable fittings.

The connections on the bottom of the boiler are all straight threaded - standard tapered fittings cannot be used to connect

to the boiler.

3/4” Pressure Relief Valve

Pressure Temperature Gauge

240011431 Rev A

NOTICE

Gas Shut Off 3/4”

DHW combi only - Inlet & Oulet Connections - copper sweat fittings

1/2”

Heating System Supply Connection - copper sweat fitting

3/4”

Heating System Return Connection - Copper sweat optional indirect connection on heating only boiler

3/4”

PN 240011430 REV D, [09/01/2016]

Page 34: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

34

MANUFACTURER RECOMMENDATION - STRAINER

Potable water OUT

Strainer

Potable water IN

Manufacturer Recommendation A strainer filtering potable water before entering the boiler is highly recommended to prevent errors and lockouts. The strainer prevents any sedimentation and debris from your water supply piping from entering the boiler. Debris carried from the water supply will clog DHW water flow sensor resulting in error codes and causing boiler to lockout.

Locate the strainer as close to the boiler as possible and place on DHW (domestic hot water) inlet connection located at bottom of the boiler.

PN 240011430 REV D, [09/01/2016]

Page 35: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

35

WARNING PRIMARY/SECONDARY CLOSELY SPACED TEES

WARNINGBURN AND SCALD HAZARD!

Primary/Secondary piping with closely spaced supply and return lines is mandatory for ASME Code Compliance. Failure to follow these instructions could

result in death or serious injury.

!

12 inch (305mm) Maximum separation

10 ft Maximum (3048mm)

PN 240011418 REV B , [05/02/2016]

Boiler

Primary/Secondary with closely spaced supply and return lines.

DO NOT Place Isolation Valves Before “T”

Check Local Codes For Maximum

Distance To Floor

PN 240011430 REV D, [09/01/2016]

Page 36: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

36

APPLICATION TABLE - INDIRECT TANK SIZING

'HEA

TIN

G O

NLY

' B

OIL

ER (1

25,0

00 B

TUH

)B

OIL

ER O

UTP

UT

(BTU

H/H

R)

MAX

. OU

TPU

T50

,000

60,0

0080

,000

100,

000

113,

000

140

F94

106

106

106

106

115

F11

913

815

815

815

814

0 F

6779

7979

7911

5 F

9211

113

113

113

1

H2O

40 /

H2O

40L

140

F10

311

511

911

911

911

5 F

128

147

174

174

174

140

F67

7983

8383

115

F92

111

138

138

138

H2O

5014

0 F

112

124

133

133

133

115

F13

715

619

219

219

214

0 F

6779

8888

8811

5 F

9211

114

714

714

7

140

F12

113

314

714

714

711

5 F

146

165

208

208

208

140

F67

7993

9393

115

F92

111

154

154

154

Not

es:

H2O

301s

t HO

UR

RAT

ING

(GAL

/HR

)C

ON

TIN

UO

US

RAT

ING

(GAL

/HR

)

1st H

OU

R R

ATIN

G(G

AL/H

R)

CO

NTI

NU

OU

SR

ATIN

G (G

AL/H

R)

1st H

OU

R R

ATIN

G(G

AL/H

R)

CO

NTI

NU

OU

SR

ATIN

G (G

AL/H

R)

176

°F B

oile

r Sup

ply

Wat

er T

empe

ratu

reAH

RI R

atin

g C

ondi

tions

- 50

°F In

let W

ater

@ 4

.0 G

PM F

LOW

RAT

E

1st H

OU

R R

ATIN

G(G

AL/H

R)

CO

NTI

NU

OU

SR

ATIN

G (G

AL/H

R)

H2O

60 /

H2O

60L

PN 240011430 REV D, [09/01/2016]

Page 37: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

37

LOW WATER CUTOFF

Low Water Cut Off - Heating Only and Combi BoilersThese guidelines are supplied when necessary to install an additional Low Water Cut Off (LWCO), for sensing a low water level condition in a boiler, as required by the Authority Having Jurisdiction. Follow LWCO manufacturer installation instructions for type of LWCO selected in addition to these instructions.

LWCO shall be 120V/60HZ control and dry contacts sized for load being connected. Wire control to boiler. See Figure 1.

Connect LWCO device to the system ground. Ground in accordance with the requirements of the authority having jurisdiction or, in the absence of such requirements, with the National Electrical Code (NEC) or Canadian Electrical Code CEC.

FIGURE 1 - LWCO Wiring Diagram

Low Water Cutoff (LWCO)

Electrical Conduit

J-Box

120 V/60 HZ

Conduit or Power Supply cord (Polarized)

L1NG

GND

L1

NGND

BLK

WHT

120 V/60 HZ Socket

(Polarized) 120 V/60 HZ Cord Set From Boiler

N.O

• Locate LWCO sensing device in the supply piping, above the minimum height of boiler. See Figure 2, Piping Diagram.

• Position control in HORIZONTAL piping to assure proper boiler protection (upright or 90° rotation).

• For proper operation, sensing element of the LWCO control shall be positioned in the tee to sense the main water stream. Maintain minimum 1/4” spacing from pipe walls. Element shall NOT contact the rear, or side walls of the tee. See Figure 3.

• Install an air vent using a tee to avoid nuisance shutdowns.

• Apply small amount of pipe sealant to threaded connections.

• Arrange piping to prevent water dripping onto boiler.

• DO NOT install water shutoff valve between boiler and LWCO sensing device.

PN 240011430 REV D, [09/01/2016]

Page 38: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

38

FIGURE 2 - Piping Diagram - LWCO Location

LOW WATER CUTOFF

Low Water Cutoff (LWCO)(See Figure 3 for detail)

Air Vent

Supply

Gas Boiler

Safety Relief Valve

Position LWCO Above Top of Boiler

2 DO NOT PLACE ISOLATION VALVE BEFORE TEE OR LWCO.

Note

2

Return

*To Drain* Check Local Codes for Maximum Distance to Floor.

2

Arrange piping to prevent water dripping onto boiler.

1 12” (305mm) Maximum SeparationNote

1

10 Ft.(31m) Maximum

Note

Illustrations are meant to show system piping concept only. Installer is responsible for all equipment and detailing required by authority having jurisdiction.

Note

PN 240011430 REV D, [09/01/2016]

Page 39: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

39

FIGURE 3 - Low Water Cutoff - Detail

LOW WATER CUTOFF

NO

NO

YES

PN 240011430 REV D, [09/01/2016]

Page 40: HEATING ONLY COMBI Condensing...PN 240011430 REV D, [09/01/2016] Manufactured for: ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 web site: This manual has been prepared

PN 240011430 REV D, [09/01/2016]