Heath Volume Corrector

HVC Series User’s Manual & Field Installation Guide

Heath Consultants Inc.

Houston, TX

713-844-1300

Fax: 713-844-1309

1-800-HEATH-US

www.heathus.com

Page 2: Heath Volume Corrector HVC Series

2

HVC Series

HVC User’s Manual & Field Installation Guide

Proprietary Notice The contents of this manual are proprietary to Heath Consultants Incorporated. Reproduction of

this manual, in whole or in part, is prohibited without the express written consent of Heath

Consultants Incorporated.

Heath Consultants Incorporated operates under a continual product improvement program and

reserves the right to make improvements and/or changes without prior notification.

Purpose of this Manual

The HVC series is a powerful device that can be assembled and programmed in a variety of

configurations. The purpose of this manual is to provide information for use in instrument shop setup and

field installations.

Models

HVC IS HPN 77R91-1000

HVC HPN 77R91-1000-1

HPN 77R91-1071, rev B

©COPYRIGHT 2011-2015, Heath Consultants Incorporated

Page 3: Heath Volume Corrector HVC Series

3

Table of Contents

HVC Series (Purpose of this manual) ............................................................................................. 2

Table of Contents ............................................................................................................................ 3

Heath Volume Corrector (HVC) Overview .................................................................................... 4

HVC Features ..............................................................................................................................4

HVC Hardware Layout ........................................................................................................... 5-6

HVC PCBoard Layout .....................................................................................................................7

Mounting & Installation ...................................................................................................................8

Equipment Required ....................................................................................................................8

Matching the HVC to the Meter Rotation ...................................................................................8

Meter Mounting ...........................................................................................................................8

Pressure Connection ....................................................................................................................8

Temperature Probe Installation ...................................................................................................9

Electrical Installation ...................................................................................................................9

Battery Pack & Back-up Batteries ......................................................................................... 9-10

External Power ..........................................................................................................................10

Pulse Outputs .............................................................................................................................10

Alarms .......................................................................................................................................10

External Modem ........................................................................................................................11

Internal Modem .........................................................................................................................12

HVC Host Operating Software ......................................................................................................13

Software Installation............................................................................................................ 13-17

Quick Start Guide ......................................................................................................................18

HVC Host Setup Detailed ........................................................................................................ 19-20

HVC Configuration Detailed ................................................................................................... 21-23

Modbus Implementation ................................................................................................................23

Downloading and Printing Data.....................................................................................................24

Configuring for use with an IP Modem ................................................................................... 25-30

Annual Checks/Procedures ........................................................................................................... 31

Pressure Calibration ..................................................................................................................31

Temperature Probe Calibration .................................................................................................31

Mechanical Index Change Procedure ........................................................................................31

Instrument Backup & Restore Configuration/Calibration.........................................................31

Main Battery Change Procedure ...............................................................................................31

Back-up Battery Replacement Procedure ............................................................................ 32-33

Back-up Coin Battery Replacement Procedure ........................................................................ 34

Replacing or Upgrading a Transducer ...................................................................................... 35

HVC Firmware Update Procedure ...................................................................................... 35-39

HVC Specifications ...................................................................................................................... 40

Troubleshooting ....................................................................................................................... 41-42

Spare Parts and Accessories.......................................................................................................... 43

Service Information ...................................................................................................................... 44

Configuration Worksheet ......................................................................................................... 45-46

Technical Support ......................................................................................................................... 47

Page 4: Heath Volume Corrector HVC Series

4

Heath Volume Corrector (HVC) Overview The HVC is a microprocessor based, self-contained system designed for the purpose of performing ideal gas

law calculations using integral pressure, temperature and volume sensing devices.

HVC Features

• Intrinsically safe: Class I Div I Group D (without internal modem).

• Single Alkaline “D” battery provides power for up to 4 years.

• Single Lithium “AA” Backup battery will provide 100% operation for up to 1 year after main

battery is depleted.

• Measures & records pressure, temperature sensors and updates Corrected and Uncorrected

volumes every meter revolution or every min (programmable).

• Continuously displayed LCD defaults to Corrected Volume. Scroll button allows Uncorrected

Volume, Pressure, Gas Temperature, Correction Factor, Main battery and Lithium Battery Voltage,

as well as any active Alarm to be displayed.

• Non-volatile Flash memory saves Calibration, Transducer Coefficients, Instrument Configuration

& Site info if all power is lost.

• Profiler data recording- Circular log: 130 days/hourly: Time/ Corrected/ Uncorrected/ Ave

Pressure/ Ave Gas Temperature.

• Event Log (Records alarms & configuration changes).

• System Alarms (H/L Press, H/L Temp, main and lithium backup battery).

• Contract Usage Alarms (High Day/ Warning Month/ High Month).

• Contract Management (Nomination/ Allocation).

• All alarms can be reset via scroll button (No laptop needed).

• Call out upon alarm.

• Remote Communications Ready (External Direct port & Internal Remote RS232’s).

• Multi-Drop to several instruments from one modem (Up to 62).

• Previous Month Total Volumes (Uncor & Corr) can be displayed on LCD.

• Max Day Volume “total” & Date stamp of Max Day can be displayed on LCD (Max Day can be

reset by holding scroll button).

• Protocols included: Sandia (Native)/ Modbus RTU or ASCII.

• Two Pulse Outputs (Uncorrected & Corrected/ Form “A”).

• Units of measure (PSIA, KPA, BAR Deg. F/ Deg. C).

• Reliable Falling magnet/ Reed switch input.

• Index uses all brass miter gears that are easily reversible for CW & CCW meter direction.

• HVC Firmware can be upgraded via PC.

• IP64, Aluminum, Powder coated paint over chromate surface prep, lockable stainless steel hasp

closure (Saltwater spray tested).

• HVC Host software will operate the HVC, RVC, XVC and LVC devices.

• HVC Host software is very user friendly.

• HVC Host is compatible with Windows 7, Windows 8, Win Vista and Win XP.

Page 5: Heath Volume Corrector HVC Series

5

HVC Hardware Layout

Figure 1

Figure 1: LCD Display List: Corrected Volume (default after 4 minutes)/ Uncorrected Volume/ Correction

Factor/ Gas Pressure/ Gas Temp/ Main Battery Voltage/ Backup Lithium Voltage/ Active Alarms. Active

Alarms will be indicated with decimal points along the bottom of the LCD and the full Display List and

actual Alarms can be viewed by scrolling.

Figure 2

Figure 2: Layout of back of HVC. Pressure connection, Temp probe, Direct comm. port, Locking Hasp &

universal mounting plate.

Display

Uncorrected

mechanical index

Scroll Button

External Modem

Wiring Port

RS232

PC Com

port

Optional Temperature

Probe Port

Optional

Transducer #2

(not yet available)

(

Universal

mounting plate

Locking

Hasp

Earth

Ground

Stud Drill spot faces

front of the meter

Pressure port

Page 6: Heath Volume Corrector HVC Series

6

Figure 3

Figure 3: Inside configuration. Refer to drawing MTM-308-1 for field wiring requirements for external

power and modem connections to maintain intrinsic safety.

Primary

battery

Earth

Ground

Stud

Back up battery

(under cover)

Reversible gears for

adapting to CW or CCW

rotating meters

Main

battery

connector

Backup

battery

connector

Page 7: Heath Volume Corrector HVC Series

7

HVC PCBOARD LAYOUT

CT

SR

TS

CD

TX

MR

XM

GN

D

GN

DP

UL

SE

IN

PU

T

GN

DT

XD

RX

D

PU

LS

E O

UT

BG

ND

PU

LS

E O

UT

AG

ND

P3

+E

P3

+S

P3 -

EP

3 -

SG

ND

P2 +

EP

2 +

SP

2 -

EP

2 -

SG

ND

P1 +

EP

1 +

SP

1 -

EP

1 -

SG

ND

GN

DG

AS

TE

MP

GNDINDEX B

STOBEINDEX A

STOBE3V SYS

GNDGAS TEMP 2

1.5VDCGND

12VDCGND

BUTTON

COM 2 COM 1 PRESS 3 PRESS 2 PRESS 1

JP5*

CR2032

3V

1 2 3

ASSY#: 77R65-9320

REV F

3.6V "AA" Lithium

OPEN

JP1*

OPTICALINDEX INPUT

MAINBATTCONN

12VDCEXTCONN

DISPLAY

BACKUP BATTERY

BACKUPBATTERYMEMORY

GAS TEMPPROBE #2

PR

OB

E #

1

DATA

MODEM DIRECT

WIRED TO

J13 J14 J11 J10 J7 J6 J5 J9

J8

J12

J1

J11

J2

(HDR Only) (HDR Only)

(HDR Only)

A= UncorrectedB= Corrected

NOTE: External connections to the pcboard should be made by using the adapter cable serial

number 77R91-1072. This cable provides a terminal strip for Pulse input & (2) outputs (J10),

Modem connections (J13) and External 12V power (J11).

* JP1: This jumper switches the lithium power from the pcboard circuit.

* JP5: When using the internal 2400 baud modem, a special harness is required for “Call out upon

alarm” feature. This harness connects Pin 2 of JP5 to Pin 6 of J13 (External modems that

stay online 100% doesn’t require this option).

Page 8: Heath Volume Corrector HVC Series

8

Mounting & Installation

Equipment Required

• Lap Top Computer (Using Win XP, Win Vista, Win 7 or Win 8) running HVC Host.

• Communications Cable (HPN 77R61-0070)

• Test Gauge, Dead Weight Tester or Accurate Pressure gauge

• Temperature Reference (If equipped with gas temperature probe)

• HVC Mounting Kit (gasket, wrench)

• Mechanics Tool Kit

Matching the HVC to the Meter Rotation

The HVC is equipped with a “Falling magnet/ reed switch” Mechanical Index Assembly. The HVC

is suitable for direct mounting on most diaphragm, rotary or mechanical turbine meters including, among

others, Rockwell, Equimeter, Roots, Dresser, Romet or American with instrument drives.

When directly mounted to a meter, the user should ensure that the mechanical index rotation of the HVC

matches the rotation of the meter. Unless otherwise specified, the HVC will be shipped suitable for

clockwise (CW) rotating meters. The proper rotation can be confirmed by spinning the drive dog on the

bottom of the instrument in the direction required by the meter. If the mechanical counter odometer

turns in the wrong direction, change rotation by engaging the optional brass gear on the horizontal shaft

on the mechanical index.

When configuring the HVC using HVC Host, the “UnCor Vol Input” will be configured by default to

“Digital Input”. This will grey out the: “Clockwise” selection and will set the “Meter Speed” to “Fast”

regardless of actual meter rotation as the falling magnet/ reed switch mechanical index is in use. If the

optional Optical Index is used, the “UnCor Vol Input” will be configured to “Opto Input” which will

enable the direction and speed selections.

Meter Mounting

The standard HVC will fit most any mechanical meter instrument drive. Use gasket (provided) between

the HVC and meter base. Mount on to top of the meter while insuring that the HVC drive pin engages

properly with the meter drive. Verify meter rotation. Secure the HVC with bolts (not supplied with

mounting kit) to the meter base.

A “Large Mounting kit” (77R61-9580) can be supplied as an option. This kit consists of mounting

hardware, test plug, isolation valve, miscellaneous fittings and 1/8” tubing to allow connection of pressure

to the HVC.

NOTE: A rotatable base plate allows for user desired orientation of the instrument. The base plate is

removed using a 5/32 hex wrench to remove four bolts. The INSTRUMENT may then be re-installed

with a different orientation. The base plate MUST maintain its original position and be positioned toward

the front of the meter indicated by a drill spot on the top of the base plate. CAUTION: TO PREVENT

DAMAGE TO THE METER DO NOT CHANGE ORIENTATION OF THE BASE PLATE ON THE

METER. ONLY CHANGE ORIENTATION OF THE INSTRUMENT.

Pressure Connection

Connect the pressure (or gas) supply to the 1/4” NPT female connector located on the back of the HVC

housing. After piping is complete, check all connections to ensure that no leaks are present. Note: For

ease and isolation of testing, the HVC large mounting kit is recommended. This kit will assist in future

calibrations and inspection while the unit is in service.

Page 9: Heath Volume Corrector HVC Series

9

Temperature Probe Installation

If equipped, the standard 6’ long temperature probe (6” x 1/4” OD) should be installed into the

appropriately sized thermowell filled with a thermo conductive medium such as glycol or alcohol. Insert

the temperature probe into the thermowell through the standard 1/4” inch NPT male fitting (provided)

until the tip of the probe reaches the bottom of the well. Secure excess armor cable length of the probe.

It may be necessary to isolate the pressure and temperature connections to the pipeline, so as not to disturb

the cathodic protection system.

Electrical installation

NOTE: Refer to drawing MTM-308-1 for field wiring requirements for external power and modem

connections to maintain intrinsic safety.

The HVC unit must be earth grounded to maintain safe operation and warranty.

The ground stud of the HVC (located on the bottom left of the instrument) must be connected to a suitable

known external earth ground (usually a dedicated ground rod and NOT AC ground). All of the major

components in the HVC are bonded together and connected internally to this ground stud. It is required

that grounding be performed, especially when an external modem and/or external power supply (which

requires a dedicated ground rod in close proximity to the safe area) is used. All cabling connecting to the

HVC must be shielded with all shields tied to case ground.

For multiple device interconnections (modems, power supplies etc.) the ground stud of the HVC must be

tied directly to this same (safe area) ground rod rather than having a separate ground rod of its own. It

may be necessary to isolate the portion of the pipe that the HVC is mounted to (with insulating flanges)

so as not to disturb the cathodic protection system.

The American Gas Association recommends grounding all electronic field devices to a driven ground rod.

This will help protect the device from transients including lightning and power surges on the pipeline.

To reduce the possibility of “secondary” lightning strike damage (damage caused by static electricity

fields in the immediate area), the above precautions are required. However, these precautions cannot

prevent damage to an instrument that receives a “direct” lightning strike.

Battery Pack and Back-up Batteries

The HVC units utilize (1) 1.5-volt, encapsulated “D” cell alkaline battery as its primary power source. The

pack supplied with the HVC consists of an alkaline dry cell and a protection circuit.

Part Number: I.S. Battery pack (Black): 77R91-1037

Part Number: Non-I.S. Battery pack (Blue or Yellow): 77R91-1091

NOTE: This battery is not rechargeable.

HVC units are shipped from the factory powered and ready to install in the field (unless otherwise

specified).

The HVC incorporates an on board uninterruptible power supply. This consists of one factory installed

“AA” lithium cell (BT1) rated at 3.6 volts. This cell is easily replaced in the field.

Part Number: 77R65-8001

The HVC incorporates an on board battery (CR2032) for backup of the profiler log. This consists of a

replaceable button style lithium battery (BT2) located on the component side of the PCB.

Part Number: 77R65-8002

Page 10: Heath Volume Corrector HVC Series

10

Normal Main battery voltage should be displayed between the ranges of 1.5 to 1.7 volts for a new battery,

and when the primary power drops below .8 volts, the unit will switch to lithium backup. Under normal

conditions, the main battery pack should last up to four years and the lithium backup battery should last

up to 1 year without power from the main battery. Lithium standby life is 7-10 years.

Note: If all three batteries lose power, the data that is stored in non- volatile memory will not be lost. This

includes Calibration, Poly (transducer) and configuration data.

Caution: When the communication cable is connected to the instrument, higher than normal battery current

is consumed. Because of this, it’s recommended to limit the time connected to the instrument.

Caution: The maximum voltage allowed on the “Main battery” input is 2 volts DC. Only use the 1.5

volt battery pack supplied by Heath. If this voltage is exceeded, a protection fuse may blow and the

warranty will be void.

Caution: To maintain the Intrinsic Safe rating, use only proper replacement batteries: main battery pack

HPN 77R91-1037, Lithium backup battery, HPN 77R65-8001, and coin battery, HPN 77R65-8002.

Contact Heath Consultants for replacement batteries and main battery packs. Refer to Annual Checks on

page 37 for replacement procedure.

External Power

The HVC can be connected to an external power source (6- 15VDC). External Power is recommended

when using modems which are externally powered.

Contact Heath Consultants for this harness.

Pulse Outputs

Form “A” type. The HVC is equipped to provide pulse outputs representative of uncorrected and corrected volume. There

are two pulse channels available and are designated “A” and “B”. The pulse outputs are two-wire open

drain. Pulser A is designated for uncorrected pulse out. Pulser B is designated for corrected pulse out.

Contact Heath Consultants for this harness.

Specifications for Pulse Outputs Pulse output electrical specification is as follows: Open drain, requires external 1 to 30 volts maximum,

25 mA maximum, and 1 K minimum load resistance. Each pulse has a standard fixed pulse width of 62.5

milliseconds with a duty cycle of 50% (62.5 ms on and 62.5 ms off). An optional 1000 milliseconds (1

sec) pulse width is also available.

Because of the wide variety of applications requiring connection to the pulse output channels,

consideration should be given to the site electrical classification as to the use of intrinsic safety barriers.

Alarms

To configure the alarms, go to Configure column/” Alarms and Nominations”:

Set the Mode to “Manual” to activate an alarm that must be reset by the HVC Host software or the scroll

button. Set to “Manual Call” to activate “Call out upon Alarm” (must have a modem connected).

Set the “Trip” value that the alarm will activate on.

Contract Management values are in Cubic Feet.

Current Readings are displayed for reference when setting the alarm values.

All alarms can be reset manually by holding the scroll button closed for more than 4 seconds. They can

also be configured and reset by using the HVC Host. An active alarm will be indicated by a lower row of

dots on the LCD display. The HVC LCD will display the active alarm by scrolling to the alarm screen.

Page 11: Heath Volume Corrector HVC Series

11

External Modem

The HVC is equipped with two RS232 communication ports. The Direct Port is dedicated to local direct

PC communication at 19200 baud using the HVC com cable. The Remote Port is used for connecting a

modem. Remote baud rates available are 300, 1200, 2400 (default), 4800, 9600 and 19200. When

configuring for a remote modem, the “Remote Modem Baud Rate” in the unit must match the baud rate of

the field modem being used. Connect the RX, TX & GND from the modem to the instrument on J13. A wiring

harness is required for this connection.

Note: If the external modem powers down to save power, the CTS wire is required to wake the modem prior to

“dialing out upon alarm”- if this feature is enabled. Otherwise the CTS wire isn’t required for inbound

communication.

Caution: When connecting the HVC to an external modem, it is recommended to connect external power

to the instrument due to higher current demand from the RS232.

CT

SR

TS

CD

TX

MR

XM

GN

D

GNDINDEX B

STOBEINDEX A

STOBE3V SYS

GNDGAS TEMP 2

1.5VDCGND

12VDCGND

BUTTON

JP5

CR2032

3V

1 2 3

ASSY#: 77R65-9320

REV F

3.6V "AA" Lithium

OPEN

JP1

DISPLAY

BACKUP BATTERY

WIRED TO

Modem Wakeup Jumper Wire

CTS

GND

RX

TX

(Only required for modems that power down)

(Only required for modems that power down)

J13

Non-Heath Modem

DS

R (

Pin

6)

GN

D (

Pin

5)

RX

(P

in 2

)

TX

(P

in 3

)

RS-232

Splice

Splice

Splice

Splice

9 Pin

12VGND

12VDC Modem Battery

12

VG

ND

External power is recommended when

connected to external modems.

Page 12: Heath Volume Corrector HVC Series

12

Internal Modem

The HVC may be equipped with an internal modem and phone line surge suppressor. The internal modem is a 2400-baud

modem. The modem is pre-configured and pre-wired from the factory, ready for remote communication. If the HVC is

equipped with the phone line suppressor, it will be connected directly into the modem’s RJ-11 connector. A 12-volt battery

pack (8 “AA” batteries) is supplied, but not connected when shipped. The user must connect prior to remote

communication. Assuming one two- minute call per day, every day, the battery should provide approximately 2 years of

service. The optional phone line surge suppressor will sacrifice itself to protect the equipment in the event of a destructive power

surge on the phone line.

To connect a phone line to the modem, insert the phone cable through the black wire gland on back of the case (see Figure

1). The cable must be terminated with a RJ-11 connector. Plug into surge protector if provided; otherwise, plug directly to

the modem.

CAUTION: The HVC must be connected to earth ground to allow the surge suppressor to operate properly.

CAUTION: Internal modem option is not currently certified for use in hazardous environments. An external modem

should be used when necessary. Refer to drawing MTM-308-1 for field wiring requirements on external power and modem

connections to maintain intrinsic safety.

CT

SR

TS

CD

TX

MR

XM

GN

D

GNDINDEX B

STOBEINDEX A

STOBE3V SYS

GNDGAS TEMP 2

1.5VDCGND

12VDCGND

BUTTON

JP5

CR2032

3V

1 2 3

ASSY#: 77R65-9320

REV F

3.6V "AA" Lithium

OPEN

JP1*

DISPLAY

BACKUP BATTERY

WIRED TO

*Jumper wire

Yellow (CTS)

Red (GND)

Gray (RXM)

Blue (TXM)

Heath 2400Baud Modem

Ph

on

e L

ine

(Wake-up wire for "Call Out Upon Alarm")

12V

Modem

Batte

ry

(Wake-up wire for "Call Out Upon Alarm")

J13

Page 13: Heath Volume Corrector HVC Series

13

HVC HOST Operating Software

HVC Host is the companion software interface to the HVC instrument. The application program provides

for configuration, calibration, local and remote communication, interrogation, data collection and data

processing.

The Auto Download feature allows automatically polling any or all the instruments (on remote

communications- modems or TC/IP) from a “Master Directory” list. This “Auto Download” feature is

included in the HVC Host and is supplied on CD ROM media. The self expanding executable “setup” file

will guide the user through the installation process.

This install will work in Windows operating systems for Win Vista, Win XP, Win 7&8. NOTE: This install must be on each workstation in a network. The data can be sent to a network drive

and be shared by other workstations that have HVC Host installed. Remember to change the “Data Paths”

of each workstation to use the same network drive and directory. DO NOT INSTALL THIS SOFTWARE

DIRECTLY ONTO THE NETWORK SERVER DRIVE.

Software Installation

To install, locate the file “HVC Host Setup 4.03.exe”. Double-click the file to install. Follow the

instructions to complete the installation process. After the software is installed, you may need to configure

the com port to directly connect to the instrument. Com 1 is very common for direct communications;

however, many newer computers are not equipped with a 9-pin connector for direct connect with the

standard com cable. A “USB to Serial adapter” may be required. Follow the instructions included with the

USB to serial adapter. After the adapter is installed and connected to the PC, go to “Start”/ Control Panel/

System/ Hardware/ Device Manager/ “Ports” (click the “+” to the left of “ports”) Look for “USB to Serial

Bridge (com xx)” Enter this port number in the HVC Host (Host Setup/ Configure Host)/ “Direct”. Any

port from 1-255 can be chosen. Note: Only the available ports will be listed in HVC Host/ Host setup

“Name” dropdown. NOTE: HVC Host requires a screen setting of at least 800 X 600.

Click “Next” to continue.

Page 14: Heath Volume Corrector HVC Series

14

Accept the agreement. Then click “Next” to continue.

Click “Next” to continue or change the default location of the HVC Host data files.

Page 15: Heath Volume Corrector HVC Series

15

Click “Next” to continue or change the default location of the data log files.

Click “Next” to continue or change the default location of the HVC Host shortcut.

Page 16: Heath Volume Corrector HVC Series

16

Select additional icons. Click “Next” to continue.

Click “Next” to continue installation.

Page 17: Heath Volume Corrector HVC Series

17

Click “Finish” to complete the installation. Select the box to view the “README.TXT” file.

Page 18: Heath Volume Corrector HVC Series

18

Quick Start Guide Note: Click “F1” key for help on any item

1. Install the HVC Host software from the CD software disk provided.

2. Setup “Host Setup” (Com 1, 19200, Direct, is most common). If your com port is different than com 1 (or you

are using a USB to serial adapter, find out the port number and select it in HVC Host/ Host Setup). (More info

on com port setup on page 13, 19-20). Make sure to use the same USB port every time to keep the same port

number.

3. Make any other changes to the Host Setup. Click OK.

4. Connect the communication cable from the PC to the back of the instrument.

5. Using the HVC Host software, select “Security” column/ “Logon Instrument”. The status bar will show

“Logged on” in green. Note: “Instrument Response Failed” will be displayed if the com port isn’t configured

correctly.

6. To configure the HVC for field use, select “Configure” column/ “Configure 1”. Select appropriate

configurations. (If no changes are made, the default values will be used). Click “OK”. (More configuration

details on pages 19-21).

7. To configure the site information: Go to “Configure” column/ “Configure 2” select "Configure/ Site Info".

Enter the site address/ Modem baud rate (If modem is equipped) & setup pulse outputs (If pulse outputs are

needed).

8. To set up the alarms: Select “Configure” column/ “Alarms and Nominations”. Select the alarm reset “Mode”

(Ignore, Manual or Manual Call) and the “trip point” of the alarm. Click “OK”

9. To reset the HVC Clock to match your computer: Select “Configure” column/ Go to “Set Real Time clock”.

Press the [Enter] key (Make sure the time & date is correct in the PC).

10. The default password configuration uses “logon” for full access and “readonly” for Read Only access. Since

the Host setup has “logon” as the default, no passwords will be prompted and full access will be granted. To

set up a “special” password for access to the HVC: Go to “Configure” column/ select “Set Access control”,

change the default password for “Full Access” or “Read-only”. The “Host Setup” has a “Default Password”.

If it matches the “Full Access” password, Full access is given- without needing to enter a password. This

“Passive Security” is best if all instruments have the same passwords and the technicians have the same

“Special” password in their computers “Host Setup”.

11. Reset the “Profiler”. “Configure” column/ “Reset Profiler”/ at Warning screen select “Yes”. This resets the

recording of hourly Volumes, pressure and Gas Temp.

12. It is recommended to “Backup” the Configuration, Calibration, Transducer Coefficients & Site info. This

same info can be sent to the same instrument (for example if the main pcboard was replaced) or the

“Configuration” can be sent to another HVC to allow consistent configuration for each instrument. To do this:

Go to “Configure” column/ select “Auto Configure”/ Backup Instrument.

13. To retrieve data or directly print a report: Select "Data", and then select the desired download or report to

view or print (Download: Profiler, Alarm log, IOR Snapshot, Configuration Log, Modem Error Log) (Print:

Profiler, Print Alarm log, Print IOR Snapshot, Print Configuration Log, Print Modem Error Log or View

Saved Fast Logs).

Page 19: Heath Volume Corrector HVC Series

19

HVC Host setup- Detailed

1. “Type” of connection: Direct (communication cable), “Modem” (remote comm.) & “Network” (IP modems

that use an IP address and is connected through internet connection).

2. “Name” of Comm port connection. Click the triangle to show the list available on the computer. (To find

your port number, in Windows, go to the “Device Manager” under “Ports”).

3. “Baud” rate setting is for certain modems that require a specific baud rate. The “Direct” connection is

19200.

4. “Parity” is used for special circumstances where there is a need to change to “Even” or “Odd”.

5. “Pre” RTS delay is for certain half-duplex radio modems that require delay before sending data.

6. “Post” RTS delay is for certain half-duplex radio modems that require delay after sending data.

7. Modem Initialization string is for “Host” modems requiring certain HAYS initialization commands. The

default (ATE0V0X4&K0) works with most modems.

8. “Hangup” string is used for “Host” modems requiring special commands to enable hanging up the modem.

1 2

3

4

7

8

5

6

Select

from

these

options

9

11

10

12

23

14

15

13

19

17

18

16

20

21

22

0

24

25

Page 20: Heath Volume Corrector HVC Series

20

9. “Default Sandia ID” is the ID for connecting to the HVC. Used for “Multi-drop” modems to uniquely

address several instruments sharing one modem. “63” is used to communicate with any HVC that it’s

connected to.

10. “Default Logon Password” is used when connecting to HVC’s. “Logon” is the default password. This

password will match with the password configured in the instrument in the “Config” column/ “Set Access

Control”. To set a custom password, change the password in the Host Setup & change all instruments

passwords to match.

11. Type a name to appear on top of the reports generated from HVC Host.

12. This value will be used in the Hourly and Monthly reports for “Beginning Time” and “Ending Time”.

13. This value will be used in the Monthly reports for “Beginning Day” and “Ending Day”.

14. Selects if “Daylight Savings Time” is displayed in the reports and throughout the display screens. The

actual time in the instrument is always in “Standard Time”, however, the HVC Host will adjust time to

display in DLS. If set to “Disable”, all time references will be displayed in “Standard” time.

15. This is the type of file and where the Profiler, IOR Database & Event Log filenames will be created from.

The “Short flat file” is the typical Profiler file format; “ODBC” is a format where all downloads are placed

in one file that’s compatible with Microsoft Access. The filename options are: Serial Number, Meter

Number and Site Address (line #1/ this is the default). These are found in Configure column/ Config 2. The

“Download .PRF & .PRO” is only used in rare cases where it’s needed to generate a file format compatible

with GMHost.

16. This is the path where all Profiler files will be saved. Data>Download Profiler.

17. This is the path where all Configuration files will be saved (The Config file contains: instrument calibration,

configuration, transducer polynomials & site info). Config>Auto Configure> Backup Instrument.

18. This is the path where all Transducer files will be “Imported” from. Note: The transducer/Poly files can’t be

saved to this location, the “Configuration” file saves the “Poly” data (Config>Auto Configure> Backup

Instrument).

19. This is the path where all IORS files will be saved. Data>Download IOR Data.

20. This is the path where Phone numbers & IP addresses will be saved in a file named “LVHMAST.DIR”.

21. This is the path where all AMR files will be saved.

22. “Restore Defaults” button. Use to change the settings in the Host Setup screen to the default settings.

23. “Restore User” button. Use to restore to the previous settings in the Host Setup screen.

24. “Session Only” button. Use to save the settings in the Host Setup temporarily until the HVC Host is closed.

25. “OK” button will save all settings in the Host Setup screen. These settings will be saved even after

restarting the software.

Page 21: Heath Volume Corrector HVC Series

21

HVC Configuration- Detailed

Configure 1 Screen

1. Meter Drive (Input Scale Factor)= (X1, X5, X10, X100, X1,000, X10,000) Should correspond to the

amount of uncorrected gas per revolution of the meter.

2. Uncorrected Volume Display Scale Factor= (X1, X5, X10, X100, X1,000, X10,000) Sets the scale for

all Uncorrected volume displays throughout the system (LCD, Display1, Profiler etc.)

3. Corrected Volume Display Scale Factor= (X1, X5, X10, X100, X1,000, X10,000) Sets the scale for all

Corrected volume displays throughout the system (LCD, Display1, Profiler etc.)

4. Uncorrected Volume= (Manual entry) Sets the reading of the Uncorrected accumulator (Usually this

reading matches the mechanical index reading to ensure proper counting).

5. Corrected Volume= (Manual entry) Sets the reading of the Corrected accumulator (Changing this

reading will not affect the hourly recording in the “Hourly Profiler”.

6. Uncorrected Volume/ Display 4-7 digits = Sets the amount of digits to be displayed on the LCD.

Otherwise referred to as “Electronic masking” of the LCD.

1

2

3

4

5

13

14

15

16

17

18

19

21

20

22

24

23

10

11

6

7

8

9

12

25

26

27

28

29

30

Page 22: Heath Volume Corrector HVC Series

22

7. Corrected Volume/ Display 4-8 digits = Sets the amount of digits to be displayed on the LCD.

Otherwise referred to as “Electronic masking” of the LCD.

8. Uncorrected Volume/ Leading blanks or Leading zeros = Sets either “Leading Blanks” or “Leading

Zeros” on the LCD.

9. Corrected Volume/ Leading blanks or Leading zeros = Sets either “Leading Blanks” or “Leading

Zeros” on the LCD.

10. Meter Factor = (Manual entry) Applies a correction factor to the input pulse count. This can correct for

a “Known and predictable” meter error. Allowable range is .95 to 1.05 (+ or – 5%).

11. Turbine K Factor = (Manual entry) Allows entering a K factor from an electronic turbine meter

(Currently this option pcboard is not available at this time).

12. Turbine Divisor = Used as a divider for the “Turbine K factor” (not currently used).

13. Base Pressure = (Manual entry) Sets the Base Pressure used in the Correction Factor calculation. Note:

Do not type “PSIG” next to the entry.

14. Zone Pressure = (Manual entry) Same as “Atmospheric Pressure” used in the Correction Factor

calculation. Note: Do not type “PSIG” next to the entry.

15. Base Temp = (Manual entry) Sets the Base Temp used in the Correction Factor calculation. Note: Do

not type “DegF” next to the entry.

16. Specific Gravity = Sets the “Specific Gravity” value of the gas for NX-19. Note: Do not type “mol %”

next to the entry.

17. Percent Carbon Dioxide = (Manual entry) Sets the “% Carbon Dioxide” value of the gas for NX-19.

Note: Do not type “mol %” next to the entry.

18. Percent Nitrogen = (Manual entry) Sets the “% Nitrogen” value of the gas for NX-19. Note: Do not

type “mol %” next to the entry.

19. Wakeup Method = (Once Per Rev or Once Per Min) Sets the interval when all sensors are read and

LCD is updated. “Once per rev” is most common, however, if a meter is turning faster than 1 rpm it’s

recommended to change to “Once per Minute” to minimize battery usage.

20. Meter Rotation= (Counter Clockwise, Clockwise or Heavy Duty Index). This option can only be used

with optical indexes. Set to “Clockwise” or HD Index ONLY- when using “optical” input (regardless of

meter rotation). Note 1: “Heavy Duty Index” is the same as “Clockwise”. Note 2: This value is not in use

for “Falling magnet/ reed switch indexes which are standard in the HVC (It is grayed out).

21. Meter Speed = Slow (15 RPM Maximum) or Fast (120 RPM Maximum). This value is not in use for

“Falling magnet/ reed switch indexes which is standard in the HVC (It’s grayed out). This option can only

be used with optical indexes (It’s grayed out when set to “Digital"). Note: Set to “Fast” will reduce the main

battery life to 3 years. Set to “Slow” or selecting “Digital” will allow up to 4 years of main battery life.

22. Pressure Mode = (Auto or fixed). Use “Auto” when using live pressure input. Use “Fixed” when using

fixed factor measurement or there is a need to lock in a pressure reading used for pressure calculation.

23. Temp Mode = (Auto or fixed). Use “Auto” when using a live Gas Temp probe input. Use “Fixed”

when using fixed factor measurement or there is no temperature probe connected. This fixed value will be

used for the Temperature part of the calculation.

Page 23: Heath Volume Corrector HVC Series

23

24. FPV Mode = (Auto or fixed). Use “Auto” to calculate FPV based on the configurations of the

instrument. Use “Fixed” when using fixed factor measurement or there is a need to lock in a specific FPV

for calculation.

25. Instrument Units = (US or Metric) When configured to US units the unit will display in Cubic Feet for

Volume/ PSI for Pressure/ Degrees F for temperature. When configured to Metric units the unit will display

in Cubic Meters for Volume/ KPA or BAR for Pressure/ Degrees C for temperature. Caution: When setting

to Metric, the values for Base Pressure, Zone Pressure, Base Temp and Transducer “Full Scale” value

MUST be manually converted to reflect the desired metric unit.

26. Metric Pressure Units = (Bar or KPA) Select which metric unit the instrument will use for pressure.

27 Display Previous Month in LCD Sequence= (Check box) This setting will add the “Total accumulated

Uncorrected volume” and “Total accumulated Corrected volume” from the entire previous month and

display it on the LCD. The LCD reading will display [“Pc” (volume)] for Previous Corrected and [“Pu”

(volume)] for Previous Uncorrected volume from the previous month. This reading will stay the same for

the month until the 1st of the next month is passed, then it will be updated with the totals from the previous

month.

28. Display Max Day in LCD Sequence= (Check box) This setting will add the “Max Corrected volume”

accumulated in 24 hours and display the volume reading and the date that the max volume occurred. The

LCD will display [“Hd” (volume)] push the scroll button again and the next screen will be the date that the

“High day” or “Max day volume” occurred. To reset this, hold the scroll button on the “Max Day reading”

for four seconds and the reading will go to zero and the date will read [- - - - - - - -] until the next Max day

occurs.

29. Previous Monthly Accumulators= (Check box) This setting will reset the Previous Monthly

Uncorrected and Corrected Accumulators back to zero.

30. UnCor Vol Input = (Digital or Opto Input) Set to “Digital” for the HVC standard “Falling magnet/ reed

switch index. Set to “Opto Input” if using the older style “optical” index used in the older LVC/XVC

instruments. Note: The HVC can use either input (when equipped).

Modbus implementation

1. Two types of Modbus can be used, ACSII and RTU.

Packet framing: ASCII Data bits=7/ RTU Data Bits=8 / Parity= Even/Odd/None / Stop bit=1.

Note 1: After setting Modbus to ASCII, the remote port will not work using the native Sandia

protocol.

Note 2: The direct port will always work with the native Sandia protocol.

2. Set up Modbus in the “Configure” column/ “Configure 2” screen.

a. Baud rate should match the baud rate of the modem connected to the remote port of the

instrument.

b. Parity: Even/ Odd/ None. Select this option for Modbus.

c. Modbus address: Default is “001” Use this for multi-dropping more than one unit to the

same modem (Range= 001- 255)

d. Modbus Mode: ASCII or RTU.

Page 24: Heath Volume Corrector HVC Series

24

DOWNLOADING AND PRINTING DATA

To download data follow the steps below:

1. Run the HVC Host software

2. Go to the “Data” column.

3. Select the report to download: “Download IOR” or “Download Profiler Report”

4. Click “save” button to save file

5. Click “OK” after file is saved

To print IOR (Instrument Operational Report) data follow the steps below:

1. Run the HVC Host software

2. Go to the “Data” column.

3. Select the report to print: “Print IOR Database”

4. Choose the filename of file to report

5. Choose the time span to report on the calendars or choose “Last Report”.

6. Select to “Send output to”:

a. Console (Creates text file and you can view the file on your screen)

b. Printer (Prints report on the printer that is attached to the computer)

c. File (must type a filename for a text document that will be created. Example: IOR.doc)

To print Profiler data using standard format follow the steps below:

1. Run the HVC Host software

2. Go to the “Data” column.

3. Select the report to print: “Print Daily” or “Print Monthly Report”

4. Choose the filename of file to report

5. Choose the time span to report on the calendars

6. Select “Send output to”:

a. Console (Creates text file and you can view the file on your screen)

b. Printer (Prints report on the printer that is attached to the computer)

c. File (must type a filename for a text document that will be created. Example: Monthly.doc)

To print Profiler data in Excel & generate a chart, follow the steps below:

1. Run the HVC Host software

2. Go to the “Tools” column.

3. Select “Convert Flat File to CSV”.

4. Choose the file to print and click “Open”.

5. Choose the Start and End of the report/ OR just click “OK”/ which will select the default, which

will include ALL data.

6. The program Excel will automatically run including the data selected.

7. Double-click between the “A” and “B” cells (at the top) to automatically size the date and time

column.

8. Select the data to graph.

9. Click the “Graph” icon in Excel. Or select the “Insert” tab and select the Chart type.

10. Follow the instructions to customize the graph.

11. If you need help using Excel, select “help” in Excel.

Page 25: Heath Volume Corrector HVC Series

25

Configuring for use with an IP modem

1. Select “Host Setup” – “Configure Host”.

2. Click the “Network” Port Selection and then click “OK”.

Click when finished

1

2

Page 26: Heath Volume Corrector HVC Series

26

3. Select “Host Setup – Master Directory”.

4. Click on the “New IP Addr” button.

2

1

Page 27: Heath Volume Corrector HVC Series

27

5. Enter the IP address, Port Number and choose a Name/Location for the installation.

In the COM Selection drop-down box, click on “Select 4 – TCP/IP” and then click “OK”.

Click “OK” back on the Master Dialing Directory window to accept the information.

The screen shown below is an example using the Heath engineering HVC instrument.

6. To begin using the IP modem it must be wired correctly, configured properly and powered up.

The HVC modem port baud rate must match the IP modem baud rate. Refer to the IP modem

manufacturer’s users manual for further information on its use and configuration.

7. Select “Comm” / “Network” / “Start Session” to begin a network session.

1

2 3

Click when finished

Page 28: Heath Volume Corrector HVC Series

28

8. Double-click the IP modem’s site name or single click the site name and then click “OK”.

Or select “New IP Addr” to add the IP address, Port number, Name/Location, Sandia ID (63 is Default

and will work with all instruments), Password (“logon” is default) & Com port selection (Select the port

with TCP/IP. Editing is also available with this screen if needed by selecting the “Edit” button.

9. While connecting to the IP modem a status window will appear.

The IP address and Port shown below are an example only. The actual values will differ.

10. Once connected, the Host screen will indicate the connected IP address in yellow at the bottom of the

window.

1

2

Page 29: Heath Volume Corrector HVC Series

29

11. Select “Security – Logon Instrument” to logon to the remote HVC. When successful, “Logged ON”

will be indicated in green at the bottom of the window.

NOTE: Please be patient while logging onto the remote HVC. It can take several seconds to logon due

to network traffic and delays.

12. To illustrate remote IP modem communication, select “Display – Display 1 Volume Report”.

Page 30: Heath Volume Corrector HVC Series

30

13. The Volume Report window will appear after the data has been gathered and communicated.

14. Remote HVC IP modem communications are available for use using the HVC Host.

When finished, exit remote IP modem communications by selecting “Comm – Network – End Session”.

The remote HVC will be logged off and the network session will end.

1

2 3

Click when finished

Page 31: Heath Volume Corrector HVC Series

31

Annual Checks/Calibrations/Procedures

NOTE: Heath Consultants recommends annual checks on the HVC.

1. Verify calibration and recalibrate if required.

2. Verify proper battery main voltage (1.2 - 1.5 volts).

3. Verify proper battery Lithium backup voltage (3.4 - 3.6 volts).

4. Change batteries if necessary.

5. Assure that index is operating properly.

6. Check for corrosion at wire terminations & around the battery itself.

Pressure Calibration:

Note: Before removing pressure from the HVC follow these steps below:

1. Using HVC Host, go to the “Calibrate” column/ select “Calibration Wizard”.

2. The HVC will lock in the last read pressure until the calibration is complete. 3. Now connect a pressure gauge or dead weight tester.

4. Select “Two Point Gas Pressure Calibration”.

5. Click “Begin”.

6. Apply 20% of full scale pressure measured with standard reference gauge or deadweight.

7. Click “Next”.

8. Wait 10 seconds to get a stable reading and click “Next”.

9. Enter Pressure reading indicated by standard gauge and click “Next”.

10. Apply 80% of full scale pressure measured with standard reference gauge or deadweight.

11. Click “Next”.

12. Wait 10 seconds to get a stable reading and click “Next”.

13. Enter Pressure reading indicated by standard gauge.

14. Click “Next”.

15. At the calibration comparison screen, click “Done”.

16. Select “Update Inst” button to save the calibration.

17. Then click the “Cancel” button.

18. A message “Procedure Complete: Instrument operation has returned to normal.

19. Click “OK” button.

Temperature Probe Calibration: Note: Before removing temp probe from the pipeline, read below:

Follow the Pressure calibration procedure except:

Step 3 is “Remove the temp probe from the pipeline & place in insulated container of ice water (32DegF).

Step 4 is Select “Two point Gas Temperature Calibration”.

Step 6 is “Temp probe already has 32degF applied to the temp probe- measure with a standard temperature gauge”.

Step 9 is “Enter Temperature reading indicated by standard gauge and click “Next”.

Step 10 is “Apply 115-125deg F to the temp probe (place in hot liquid in a insulated container)- measured with a standard temperature gauge”.

Step 13 is Enter Temperature reading indicated by standard temperature gauge.

Main battery change procedure: (Recommended) Download all data & backup the HVC Configuration file. Make sure the lithium backup battery voltage is 3.5-3.6v. Pull the main battery connector off and remove the main battery. Connect the new main battery and route the battery wire away from the index. Secure the battery with o-ring.

Note: To clear ANY alarm, Hold the scroll button for more than 4 seconds. The main battery HPN is 77R91-1037.

Mechanical Index change procedure: Remove the plate covering the main pcboard. Disconnect the index connector

(J-11) at the main pcboard. Remove the (2) ¼-20 nuts & washers behind the index. Lift the index out carefully.

To install: Place the index over the ¼-20 studs. Carefully align the coupler making sure the index is sitting flat and level. Install the washers and nuts and secure with 7/16” socket. Tip: Use a small screwdriver or “Allen wrench” to guide the washer and nut onto the stud. Route the wires and install the connector on the main pcboard. Re-install the plate that covers the main pcboard. The standard index HPN is 77R61-9719.

Instrument Configuration Backup procedure: Using HVC Host, select the “Configure” column, select “Auto Configure”, select “Backup Instrument”, select “Save”.

Instrument Configuration Restore procedure: Using HVC Host, select the “Configure” column, select “Auto Configure”, select “Restore Instrument”, select “Restore”, select the file to restore, Select only the items to restore or choose “All the above”, select “OK”.

Page 32: Heath Volume Corrector HVC Series

32

Back-up Battery Replacement Procedure

This procedure describes how to replace the lithium back-up battery BT1 (HPN 77R65-8001) and the

profiler back-up coin cell battery BT2 (HPN 77R65-8002). It is recommended to replace both batteries at

the same time. If configured, the instrument will alert the user of a low lithium back-up battery on the LCD

and via being connected to the instrument either by direct RS-232 or modem.

Replacing the lithium back-up battery: Warning – make sure the main battery voltage is at least 1.2

Vdc!

1. Remove the metal shield from the PCB. Take care not to lose the hardware.

2. Locate BT1 in the lower middle part of the PCB. Refer to the photos below:

3. Lightly push down on the center retainer clip and use a small, thin bladed screwdriver to gently pry

the latches on the retainer clip free from the holder.

4. Remove the lithium battery and retainer clip from the holder.

Page 33: Heath Volume Corrector HVC Series

33

5. Remove the retainer clip from the lithium battery.

6. Observe the correct polarity of the lithium battery in the holder and insert the new lithium battery

into the holder.

***WARNING: Reverse battery polarity may cause a fuse to blow on the PCB.

7. Install the retainer clip over the lithium battery and verify both latches seat properly onto the holder.

Page 34: Heath Volume Corrector HVC Series

34

Back-up Coin Battery Replacement Procedure (This battery saves the Profiler memory if both the Main and Lithium battery power are lost)

Note: Replace coin battery with a number CR2032 battery.

Warning – make sure the main battery voltage is at least 1.2 Vdc!

1. Locate BT2 in the lower left corner of the PCB.

2. Insert a small, thin bladed screwdriver into the gap on the left side of the battery and gently pry the

left side up.

3. Remove the old battery. With the “+” of the new CR2032 coin cell battery facing up and at an

angle, insert the battery under the two clips on the right hand side of the holder.

4. Push down on the new CR2032 coin cell battery until it snaps into its holder.

5. Install the metal shield back over the PCB with its hardware.

Note: To clear all alarms, hold the scroll button closed for more than 4 seconds.

Page 35: Heath Volume Corrector HVC Series

35

Replacing or Upgrading a Transducer

1. Physically install the transducer into the bulkhead using the proper thread tape.

2. Install the bulkhead into the housing making sure the gasket is in place.

3. Remove the main pcboard cover-plate (Remove the (4) nuts on the corners).

4. Plug the transducer into the upper right-most connector (J5).

5. Go to Calibrate column/”Import Poly file” & select file for the transducer that will be added (If this file is

not found, contact Heath Consultants tech support to get this file emailed).

6. Go to the “Calibrate” column/ “Calibration Wizard”/ select “Two Point Gas Pressure Calibration”.

7. Click “Begin”.

8. Apply 20% of full scale pressure measured with standard reference gauge or deadweight.

9. Click “Next”.

10. Wait 10 seconds to get a stable reading and click “Next”.

11. Enter Pressure reading indicated by standard gauge and click “Next”.

12. Apply 80% of full scale pressure measured with standard reference gauge or deadweight.

13. Click “Next”.

14. Wait 10 seconds to get a stable reading and click “Next”.

15. Enter Pressure reading indicated by standard gauge.

16. Click “Next”.

17. At the calibration comparison screen, click “Done”.

18. Select “Update Inst” button to save the calibration.

19. Then click the “Cancel” button.

20. A message “Procedure Complete: Instrument operation has returned to normal.

21. Click “OK” button.

22. Go to “Display 4 /Calibration Terms” to confirm the calibration date-stamp has been updated.

HVC Firmware Update Procedure (This update will not delete Cal & CFG. However, it WILL delete historical Profiler data & zero Uncorrected

& Corrected volume readings). To get the firmware file, contact Heath Consultants Inc. tech support.

1. If historical data is needed, download the Profiler first (Data/Download Profiler).

2. Go to: Display/ Diagnostics/ “HVC models update ROM”.

3. At the “Warning” screen, select “YES”.

4. Enter YOUR User Name (Min 3 digits/ Your initials or first name will work).

5. Select “Load” (Do not change the selection“Firmware W/O Cfg & Cal”- * Unless the firmware has a problem

and the memory needs to be reset). Selecting “W/O” CFG & Cal” will save the Calibration & CFG.

6. Select the “Hex” file: (HVC_Firmware_403.a43).

7. Select “Open” to start loading the firmware file (HVC_Firmware_403.a43).

8. Watch & wait: The program will show “addresses” and “bytes written” while programming the firmware.

9. Select “Cold Start” when “Status” shows “Program Loaded Successfully” (This will clear the Profiler log

memory). Warning: Selecting “Warm Start” will also erase the Profiler log memory.

10. Exit to normal operation.

If firmware is loaded “With default Cfg & Cal”, follow these steps to load the transducer data, CFG & Cal:

11. Go to the “Configure” column, select “Auto Configure”, select “Restore Instrument”.

12. Select the file to restore & click “Open”. (If no file has been previously saved, contact Heath for this file).

13. Select “All of the Above” and click “OK”. At the “Confirming” window, click “OK”.

14. It’s recommended to reset the Profiler following any scale factor configuration changes.

Page 36: Heath Volume Corrector HVC Series

36

Follow Procedure to Update HVC Firmware

Logon to the instrument (Security/ Logon)

Select “Display” column

Select “Diagnostics”

Select HVC Models Update Rom”

At the “Warning” window, select “Yes”

#3

#2

Page 37: Heath Volume Corrector HVC Series

37

#6

Same filename

#7

#4 Enter YOUR name

here

Select this to save Cal & CFG

Select this to default Cal & CFG (This clears

all CAL & CFG & will need to be restored).

This clears Cal & CFG.

#5

Page 38: Heath Volume Corrector HVC Series

38

Watch & wait

#8

Active during update

Programming firmware

Successful

#9 #10 Exit to normal operation

Page 39: Heath Volume Corrector HVC Series

39

#12

#11

#13

Page 40: Heath Volume Corrector HVC Series

40

HVC Specifications

Functionality Profiler Data Recording: Circular log; 130 days/hourly; Time/Corrected/Uncorrected/Ave Pressure/ Ave Gas

Temperature

Non-volatile Flash Memory: Prevents loss of calibration and configuration if all power is lost

Event Log: Records alarms & configuration changes

System Alarms: H/L Press, H/L Temp, Main and back-up Battery

Contract Usage Alarms: High Day; Warning Month; High Month

Contract Management: Nomination, Allocation

Communication Protocols: Sandia (native); Modbus RTU; Modbus ASCII

Pressure ranges available (shown as PSIG): 1, 3, 6, 15, 30, 60, 100, 150, 300, 500, 1000, 2000, 3000, 5000

Units of Measure: PSIG, KPA, BAR, Deg. F, Deg. C

HVC Host: Win 7&8, Win XP & Win Vista Compatible & works with: HVC, RVC, XVC & LVC instruments

Supercompressibility Calculation Method: NX-19

Mechanical Housing: Aluminum

Dimensions: Overall 8.65” x 6.25” x 4.65”

Weight: 6 lbs (including battery)

Mounting: Universal rotatable base plate

Pressure Connection: ¼” NPTF

Temperature Probe: ¼” O.D. x 6” probe x 6’ long armor; ¼” NPTM slip fitting

Security: Stainless steel padlock hasp

Coating: IP64, Aluminum, Powder coated paint over chromate surface prep

Display Scroll: Push button switch

Drive Mechanism: Universal drive dog, reversible mechanical Brass gear train

Display: Odometer style index, eight digits uncorrected volume counter

Electrical Primary Power Pack: 1.5 volt; 1 “D” cell alkaline battery with IS protection board.

Back Up Power: 3.6 volt field replaceable lithium cell

Transducer: 10 millivolt per volt excitation; 12 point polynomial compensation

Temperature Sensor (gas and air): Integrated circuit type

Flow Detector: Falling magnet/ reed switch input pulse

Display: LCD continuous eight digits/ displays Corr & Uncorr volume, C.F., press, temp, batt volts & alarms

(defaults to Corrected volume reading after 4 minutes)

Com 1: RS-232 via serial cable (If a 9-pin connector isn’t available on the PC, use a USB to Serial adapter)

Com2: RS-232 modem & multi-drop addressable, Sandia (native protocol) or Modbus

Performance Accuracy: +/- 0.5% of reading inclusive of linearity, hysteresis, repeatability, long term drift & temperature

Temperature: -40°F to + 170°F

Humidity: 5 – 95 % non-condensing

Primary Power Pack Life: Up to 4 years based on a 1 minute wake-up interval

Back-Up Power Life: Up to 1 year based on a 1 minute wake-up interval

Options External power: Allows connecting 6V-15VDC from external power source

Communication: Internal 2400 baud “land line” modem, Multi-drop capable, external Radio modem, Cell

modem, IP Modem, surge protection

Certifications Intrinsic Safe: UL 913 and CSA C22.2, Class I, Division 1, Group D

CE: EMC directive EN 61326-1

Corrosion Resistance: MIL-STD-810F

Page 41: Heath Volume Corrector HVC Series

41

HVC Troubleshooting

The following may serve as a quick troubleshooting guide if you encounter problems in operating the

HVC:

Symptom Diagnosis

Will not log on Verify that proper com port is selected in HVC Host/ “Host Setup”.

(If a Serial to USB adapter is used, find out the proper com port selection

in the Windows “Device Manager”)

If error “Com not ready to send” check to see that only 1 session of

HVC Host is running. After correcting problem, it may be necessary to

reboot the computer.

Make sure that “Default Sandia=ID” in “Host Setup” is set to 63.

Check Com cable with ohmmeter

Check if pushbutton will scroll unit

Check battery voltage on LCD

Call factory for assistance.

Call factory for assistance

Will not scroll

Check battery voltage (Replace if necessary)

Test scroll switch with ohmmeter

Restart instrument: Document volume readings, Remove main power

connector and then remove the lithium jumper (JP 1) on the PCB. Wait 2

minutes, reconnect the main power first (with good battery), then re-

connect the lithium jumper. Re-enter volume readings & reset “Real Time

Clock” (Config 1/ Profiler data may be lost after restart).

Call factory for assistance.

Display is blank

Check main & lithium battery voltage

Replace all batteries if necessary

Check lithium jumper (Scrape pins with a knife to clean if necessary)

Restart instrument. Remove and replace batteries and reconnect.

Call factory for assistance.

Not responding to

applied pressure

Confirm pressure mode set to AUTO

Check connections of transducer wires

Check “Full Scale” value in poly file. Calibrate column/ “Edit Calibration

Terms”, enter the correct “Full Scale”

Set the pressure calibration to default. -> “Calibrate” Column/ “Edit

Calibration Terms” -> click the check box next to Pressure Calibration

“Default”. Note: Recalibrate Pressure after these steps.

Replace transducer and recalibrate

Call factory for assistance

Pressure not correct

in Profiler (Display &

LCD is correct)

Reset profiler to update the Profiler header. (“Configure” Column/ “Reset

Profiler”. At the “Warning” screen, click “Yes”. Warning: This will erase

all Profiler data. If data is needed, download Profiler data first.

Instrument is locked

up or not functioning

correctly

Reload instrument firmware. Remove all power (Main batt & Lithium

jumper-J1). Wait 2 mins. Hold scroll button, then connect the main

battery first, then connect lithium jumper. The LCD should show: - -

Lodr- -. Follow the procedure on page 30-32 selecting “Firmware (W

default Cfg & Cal)” and “Cold Start” to ensure all memory is cleared.

Then send config file: Config/ “Auto-config”/ “Restore Instrument”

Page 42: Heath Volume Corrector HVC Series

42

Symptom Diagnosis

Not responding

to temperature

(Possible

“Fault” display)

Confirm temperature mode is set to AUTO

Check connections of temperature probe wires.

If “Fault” is displayed, this could indicate a bad temp probe connection.

Set the Gas temp calibration to default. -> Calibrate Column -> Edit

Calibration Terms -> click the check box next to Gas Temp Calibration

“Default”. Note: Recalibrate Gas Temp after these steps.

Replace with a known good temperature probe, retest & recalibrate.

Call factory for assistance.

Instrument Shows

“Fault” (T-probe or

power cycle)

Reset “Fault” by going to the “Configure” Column/ “Alarms and

Nominations”, select “Reset All Active Alarms” or hold the scroll switch

for more than 4 seconds.

Abnormally high

accumulator

value(s) factors

Check Uncorrected, Corrected and Meter Drive factors are proper.

Make sure that the index- Magnet/ reed switch is operating properly.

Call factory for assistance.

Abnormally low or

no accumulator

value(s)

Check Uncorrected, Corrected and Meter Drive scale factors are proper.

Check instrument configuration & make sure UnCor Vol Input is set to

“Digital”.

On Index, make sure magnet is dropping passed the reed switch.

Check to see that the index is not binding or gears are not slipping.

Check wiring between index reed switch and the main board.

Replace index or try new reed switch.

Call factory for assistance.

Error downloading

Profiler file: “Invalid

Host File.

Rename, move or delete the host profiler file and then re-download the

Profiler data. This allows a new file to be created.

Call factory for assistance.

When calling the factory or your area representative for further troubleshooting, please have the

following information ready:

Customer Information

1. Name(s)

2. Company

3. Phone Number(s)

4. Location (site I.D.)

Hardware Information

1. Model of Instrument

2. Instrument Firmware Version

3. Battery Voltage.

4. Instrument Serial Number

5. Date of Manufacture

6. Transducer Serial Number(s) (If Applicable)

7. Any externally connected devices

8. Phone Number (If Applicable)

9. Most Recently Printed IOR Report (If Applicable)

Page 43: Heath Volume Corrector HVC Series

43

Spare Parts & Accessories Pressure Transducer

The HVC may be equipped with a wide variety of ranges, most of which are available in either gauge or

absolute.

Temperature Probe

Temperature Probes are normally supplied with six-foot long metal sheathed cable. Contact factory

for non-standard lengths. The temperature probe is HPN 77R91-1035.

Modem (Internal Modem Assembly Retro Kit Part #77R61-9360)

Contact the factory for other configurations. Heath industrial modems are available in one of two

configurations–internal or external.

The standard HVC is ready for remote RS232 communications (with modem wiring harness). This will

allow many different communication options: CDMA (Cellular), IP, Radio, LAN or Satellite modems.

DESCRIPTION Heath PART# Communication Cable (6’/9pin) 77R61-0070

Battery Pack (I.S.) Black 77R91-1037

Battery Pack (Non I.S.) Blue or Yellow 77R91-1091

O-ring for battery Pack holder 77R91-1037

Lithium Back-up Battery 77R65-8001

Coin Battery 77R65-8002

Modem (Internal 2400 Dial-up)

Spare Internal Modem Battery Pack 77R61-9370

Telephone Surge Protector 77R61-9366

Internal Modem Assembly Retro Kit 77R61-9360

(Does not include surge protector)

Mounting kits

Standard HVC Mounting Kit 77R61-9220

Large HVC Mounting Kit 77R61-9580

Index Assembly 77R61-9719-1

Spare PC Boards

Spare Main PCboard 77R65-9320-1

Spare Internal/External Modem PCboard 77R65-9216

External Temp Probe (6’ cable X 6” probe) 77R91-1035

Spare Transducers Contact factory

External modem harness (locking connector) Contact factory

External modem harness (for dial out upon alarm) Contact factory

External power harness (locking connector) Contact factory

Pulse output harness 12V (locking connector) Contact factory

HVC Host software Contact factory

Page 44: Heath Volume Corrector HVC Series

44

Service Information: Warranties and Warranty Repair

The HVC is warranted to be free from defects in material and workmanship for four (4) years from date of

shipment (exclusive of the batteries).

The warranty on authorized repairs in the Houston Factory Service Center (FSC) is ninety (90) days for

materials and labor. This repair warranty does not extend any other applicable warranties.

Our warranty covers only failures due to defects in materials or workmanship. It does not cover failure due

to damage which occurs in shipment, unless due to improper packing.

It does not cover failures, which result from accident, misuse, abuse, neglect, mishandling, misapplication,

alteration, modification, or service other than the Houston FSC or other authorized repair center.

Batteries and damage from battery leakage are excluded from this warranty.

HEATH’s responsibility is expressly limited to repair or replacement of any defective part, provided the

product is returned to HEATH FSC or an authorized FSC, shipped pre-paid, and adequately insured.

Return shipping and insurance will be at no charge to the purchaser.

HEATH does not assume liability for indirect or consequential damage or loss of any nature in connection

with the use of any HEATH product.

There are no other warranties expressed, implied, or written except as listed above.

Obtaining Service To expedite the repair of your instrument, please follow the following procedure:

1. Contact HEATH Customer Service at 1-800-HEATH-US to obtain a Return Authorization

tracking number. Repairs can be significantly delayed until authorization is obtained.

a. Specify your complete shipping and billing address.

b. Specify the person and contact information to be contacted for repair and shipping

authorization.

c. Specify the instrument product name and serial number.

d. Include a brief description of the problem you are experiencing.

e. Specify the person and contact information to be contacted for additional information

regarding the symptoms of the failure.

2. Package and ship the HVC to the appropriate location.

3. Please specify the tracking number, product name, and serial number on all correspondence.

Page 45: Heath Volume Corrector HVC Series

45

Configuration Worksheet Complete this worksheet prior to leaving the meter shop to facilitate field configuration and

documentation.

Always remember to download the IOR Snapshot or Configuration Log reports as a record of

instrument configuration.

Site Information: Site Address: Unit Serial #: ____ ___ _ Site/Meter ID: ________

Configuration Item Value

Meter Drive (Input Scale Factor):

Uncorrected Volume Display Scale Factor:

Leading Digits:

Leading Blanks:

Corrected Volume Display Scale Factor:

Leading Digits:

Leading Blanks:

Uncorrected Volume:

Corrected Volume:

Base Pressure:

Zone Pressure:

Specific Gravity:

Percent Carbon Dioxide:

Percent Nitrogen:

Wakeup Method:

Meter Rotation:

Meter Speed:

Pressure Reference:

Pressure Mode:

Temperature Mode:

Fpv Mode:

High Pressure Alarm Mode:

Trip Point:

Low Pressure Alarm Mode:

Page 46: Heath Volume Corrector HVC Series

46

Configuration Item Value

Trip Point:

High Temperature Alarm Mode:

Trip Point:

Low Temperature Alarm Mode:

Trip Point:

Low Battery Volt Alarm Mode:

Trip Point:

High Contract Month:

Trip Point:

Warning Contract Month:

Trip Point:

High Contract Day:

Trip Point:

Nomination:

Allocation:

Time Zone:

Start of Day Hour:

Start of Month Day:

Output Pulses Y/N:

Uncorrected Pulser Scale Factor:

Corrected Pulser Scale Factor:

Output Pulse Rate 8 per sec. or 1 per sec. :

Modem Configuration Value

Remote Modem Baud Rate:

Parity:

Sandia ID:

MODBUS Address :

MODBUS Mode :

Alarm Host Number:

Modem Init String:

Modem Hang Up String:

Page 47: Heath Volume Corrector HVC Series

47

Technical Support

1-800-HEATHUS (1-800-432-8487)

Heath Consultants Factory Service Center

9030 Monroe Road

Houston, Texas 77061

Phone: (713) 844-1350

Fax: (713) 844-1398

Heath Consultants Incorporated operates under a continual product improvement program and reserves the right to make

improvements and/or changes without prior notification.