Page 3: Havells fixture presentation final   bryan

One of Europe’s most respected commercial and architectural lighting brands Renowned for its strong design ethos, high technical performance and aesthetic form

Wide range of contemporary designed fixtures Intended for lighting medium to large projects (shops, offices, hotels and restaurants)

Brand Portfolio

Strong dominant brand in the India home market

Page 4: Havells fixture presentation final   bryan

A full-spectrum provider of professional electrical solutions worldwide

An Expanding Global Leader

U$1.4 Billion +One of the world’s largest lighting and electrical product companies

Global HQ:Noida, India

Page 5: Havells fixture presentation final   bryan

InnovativeHighest quality standardsStrong distribution strategyStrong brands

ISO certified & EU-Eco Audit

62%

27%8%

3%

0% 10% 20% 30% 40% 50% 60% 70%

Wholesale

Retail

OEM

Enduser

HAVELLS World Wide

Page 6: Havells fixture presentation final   bryan

Full Line Lamp Manufacturer

Lamps

Page 7: Havells fixture presentation final   bryan

Full Line• T8 Electronic Fluorescent• T5 Electronic Fluorescent

• Quick connect• Leads

Limited Line• T12 Electronic Fluorescent• Electronic CFL

Full line magnetic• Metal Halide• HPS

Havells Brand

Ballasts

Page 8: Havells fixture presentation final   bryan

Full Line Fixture Manufacturer

Fixtures

Page 10: Havells fixture presentation final   bryan

10

One-stop shoppingInnovative range of lamps Broad selection of fixturesEfficient ballast

Professional Lighting Solutions

Page 11: Havells fixture presentation final   bryan

11

Residential Industrial Outdoor

Retail & Display Commercial Hotels & Leisure

Major Target Segments

Page 12: Havells fixture presentation final   bryan

VAPORTITE FIXTURE LAUNCH Fluorescent T5 &T8 FIXTURES

Page 13: Havells fixture presentation final   bryan

FEATURES BENEFITS

Durable fiberglass housing Adaptable to any adverse conditions

Poured in place gasketing Allows enclosure to be sealed from harsh environments

Injection molded diffuser Shatter resistant lens reducing breakage

Corrosive resistant latches Standard on all units

Stainless steel mounting clips For easy installation

Energy Efficient Available with T5 or T8 lamp options

Lightweight Easy to mount

Easy ballast removal Removable gear tray for access

Rubber end plug For utilization of standard die cast liquid or water tight fittings

IP67 Rated Dust tight rated and temporary immersion in water

NSF Splash Zone Certification Approved for washdown environments

Vaportite (VP Series) - Fluorescent T5 & T8

Page 14: Havells fixture presentation final   bryan

ISO 9001-2000 & ISO 14001

Fixture Plant in Costa Rica

Page 15: Havells fixture presentation final   bryan

Specification Sheets

Page 16: Havells fixture presentation final   bryan

Stainless Steel mounting clips

Rubber End Plug

Removable Gear tray for ballast access

Injection molded diffuser

Polycarbonate Latch to secure lens

Exploded View

Page 17: Havells fixture presentation final   bryan

Latching Options: Clear Polycarbonate or Stainless Steel. Both options can easily be made tamper resistant.

Stainless Steel Latches are securely held in place to prevent loss during maintenance.

Simple Mounting SystemReduces installation labor

costsNo holes drilled through the

housingVariable mounting centersUL rated

BailsOptional bail provides convenient means of suspending the fixture

Stainless Steel Mounting Clips

Accessories

Page 18: Havells fixture presentation final   bryan

Insert one side of the Vaportite housing into the mounting brackets.

Securely attach mounting brackets (2) mounting surface. The Vaportite enclosure will engage the mounting brackets at any point along it’s length, except for where there are latches. It is recommended that the dimension between brackets equal about 70-80% of the enclosure’s length.

Installation

Page 19: Havells fixture presentation final   bryan

T5 High Output Fluorescent LampT8 & T8HO Fluorescent Lamp3 Lengths (2’, 4’ and 8’)2, 3, 4, 6 lamp x 32 T8 watt or 54 T5

wattPendant or surface mountedSupplied with SLI ballastUniversal voltage (120 volt to 277

volt) standard

Vaportite T5 & T8 Fixture

Page 20: Havells fixture presentation final   bryan

Protection Against Solid Objects Protection Against Liquids

First No. Definition Second No. Definition

0 No protection 0 No protection

1 Protected against solids objects over 50mm (e.g. accidental touch by hands.)

1 Protected against vertically falling drops of water

2 Protected against solids objects over 12mm (e.g. fingers)

2 Protected against direct sprays up to 15 from the vertical

3 Protected against solids over 2.5mm (e.g. tools and wires)

3 Protected against direct sprays up to 60 from the vertical

4 Protected against solids objects over 1mm (e.g. tools, wires and small wires

4 Protected against sprays form all directions – limited ingress permitted

5 Protected against dust – limited ingress (no harmful deposit)

5 Protected against low pressure jets if water from all directions – limited ingress permitted

6 Totally protected against dust (dust tight) 6 Protected against strong jets of water (e.g. for use on shipdecks – limited ingress permitted

7 Protected against the effects of temporary immersion between 15cm and 1 m. Duration of test 30 minutes

8 Protected against long periods of immersion under pressure.

IP Rating System (IP67)

Page 21: Havells fixture presentation final   bryan

NSF Certification Description of Location/ Use and Commentary Typical Lighting Applications

Non-Food Zone Areas where direct contact with food products during normal operations would not be expected. Equipment is located outside the normal washdown area. There is a concern that the fixture will add contamination to the protected space or food product (i.e. Cleanability - will the finish withstand cleaning, chipping paint, deteriorating paints or finishes, lens impact resistance, lamp glass breakage, etc.

Kitchens; food storage dry process areas; damp process areas – no drip possibility

Splash Zone Areas where direct contact with food products during normal operations would not be expected; however , the fixture may be situated such that liquids used in the process or cleaning procedures, may splash, spill or otherwise soil – either intentionally or inadvertently – the surface on the fixture. There then is the potential for dripping or draining onto other surfaces or even the process. Since these fixtures are often used in washdown areas, a Wet Location listing is not sufficient. Fixtures must be tested to withstand high-pressure hose washdown. The concerns of Non-Food Zone also apply.

Wet or damp process areas; high pressure purging or decontamination used in the process; area hose washdown

Food Zone Areas where direct contact with food products is normally expected and surfaces from which the food may drip, drain, or splash back onto surfaces normally in contact with food. Equipment other than lighting fixtures typically require this certification (i.e. work tables, cutting boards, other direct contact equipment.

Category not typically used for lighting

NFS Certification (Splash Zone Rated)

Page 22: Havells fixture presentation final   bryan

CENIT FIXTURE LAUNCH Fluorescent T5 &T8 High Bay Lighting

Page 23: Havells fixture presentation final   bryan

• Very low profile • Only 2.4’ deep/ Lightweight for easy installation.

• Mounting Options • Can be surface or pendant mounted.

• Pre-wired for multi level switching • Provides for 2 levels of lighting

• Anticorrosive treated steel housing finished with electrostatic powder coating after fabrication

• No sharp edges with anti rust capabilities

• Anodized aluminum reflector designed specifically for each available lamp configuration

• Highly reflective surface yielding very high fixture efficiencies

• Side mounted ballasts • Allows ballast to maintain a lower ambient temperature

• Havells manufacturing facility builds every fixture • Complete control and adaptability over all aspects of manufacturing

• Quality Control • Each fixture is lamped and energized in factory

• Energy efficient • Reduces operation costs with a superior quality of light

• Availability • Most common configurations are in stock

• Several Options • Available with cable mounting kits, wireguards, 6 ft. cords, emergency ballast, door frames with clear lens, and occupancy sensors

CENIT Fluorescent T5 & T8 High Bay Lighting

Page 24: Havells fixture presentation final   bryan

Specification Sheet

Page 25: Havells fixture presentation final   bryan

Ballast Access

Access to ballast removing side reflector sections

Page 26: Havells fixture presentation final   bryan

• Overheat test• Ballast temperature remained below 90°C limit• Heat emitted by lamps doesn’t rise towards ballasts

10 20 30 40 50 60 70 80 90 100 110

Component Temp on Cenit 6x54w

4x54w Ballast

2x54w Ballast

Lamp (center)

Ambient Temp C/F°

120/248

40/104

100/212

20/68

40/104

60/140

80/176

100/212

120/248

80/176

60/140

Co

mp

on

ent

Tem

p

C

/F°

Not recommended for applications with ambient temperature above 35°C (95°F) due to lamp output reduction

Thermal Impact of Ballast Location

Page 27: Havells fixture presentation final   bryan

• Can be surface or pendant mounted• Hanging kit must be attached to at least two points on the ceiling

Installation

Page 28: Havells fixture presentation final   bryan

• UL required labels and hanging cable kit installation

Stop sleeve on all four hanging kit cables. Must pass through this hole and slide inward.

Surface mount holes.

Labels on Fixture Body & Cable Kit

Page 29: Havells fixture presentation final   bryan

Installation Instructions

Page 30: Havells fixture presentation final   bryan

• 3D model view from below - guard attached

Wideguard (Currently being developed)

Page 31: Havells fixture presentation final   bryan

T5 High Output Fluorescent LampT8 Fluorescent Lamp3 Fixture sizes

14” wide25” wide33” wide

2, 3, 4, 6, 8 x 32W or 54WPendant or surfaceSupplied with Havells USA ballast

4 lamps 1 ballast6 lamps 2 ballasts8 lamps 2 ballasts

Universal voltage (standard)

CENIT Fluorescent T5 & T8 High Bay

Page 32: Havells fixture presentation final   bryan

• Example of incorrect application of high bay fixture for low bay site

49%

34%

15%

2%

Reflector Performance

Page 33: Havells fixture presentation final   bryan

AdvantagesHigh efficiency (energy savings and photometricaly efficient).High CRI, instant restart, and double circuit for energy saving.Less weight on structures, less heat emission.Return on Investment (ROI) advantage.

Top view of warehouse. Illumination simulation by Marketing’s Projects Dept.

6 Cenit 4x54w T5HO

5 MH 400w

5 Cenit 6x54w T5HO

1,182 watts/21 FC avg.

2,485 watts/19FC avg.

1,550 watts/30FC avg.

CENIT T5 High Bay Retrofit

Page 34: Havells fixture presentation final   bryan

5 10 15 20

Life in thousands of hours

10

20

30

0

Thou

sand

s of

em

itted

lum

ens

Cenit 6x54W T5HO

Metal Halide 400W

Comparison of luminous maintenance & energy savings for a 6 Lamp Fixture

310W

475W

Replacement Costs

(Replace 1–400W MH HID with 1-6 lamp T5HO High Bay fixture)

$185 installed & lamped

165 watts/fixture of energy savings

Over 50% increase in lighting levels

Return on Investment

(ROI) = 20 months

CENIT T5 High Bay Retrofit