hanover engineering feb 15 civil engineer report - nestle project in eldred township
TRANSCRIPT
-
8/17/2019 Hanover Engineering Feb 15 Civil Engineer Report - Nestle Project in Eldred Township
1/5
ng
r ng
s s o c
a t e s
In c
February 15, 2016
Mary Anne Clausen, Chair
Board of Supervisors
Eldred Township
P.O. Box 600
490 Kunkletown Road
Kunkletown, PA 18058
Dear Mary Anne:
RE: Special Exception Review
Deer Park - Chestnut Springs Project
Hanover Project ELD15-21
We are in receipt
of
the following materials related to the above-referenced Project:
• A Site Plan consisting
of
fifteen
15
sheets, prepared by Miller Bros. Construction,
Inc., dated December 10, 2015.
• One
1
copy
of
the Deer Park - Chestnut Springs Project Volume 1 of 3
Application, Environmental Impact Statement, and Erosion and Sediment
Control/Stonnwater Management Plans.
• One 1 copy of the eer Park - Chestnut Springs Project Volume 2 of 3
Hydrogeological Report, prepared by EarthRes Group, Inc., dated December 2015.
•
One
1
copy
of
the Deer Park - Chestnut Springs Project Volume 3
of
3 Traffic
Impact Study, prepared by Pennoni Associates, Inc., dated December 2015.
This site is
located
in
Eldred Township, Monroe County, south east
of
the intersection of
Chestnut Ridge Road SR 3001 and Kunkletown Road
SR
3004 . The Applicant proposes to
access the site via an unnamed Township Road to Chestnut Ridge Road.
We have reviewed this Special Exception Use Application with respect to the applicable
Township Ordinances and general engineering practice and have the follo\.ving comments to offer:
StTBDIVISIO - A_
TD
L N EVELOPME T ORDINA_ TCE:
A Land Development
will
be required for this project zoning approval
received. A
Subdivision and Land Development re\-iew
\. ill
be perfonned upon receipt
of
the Land
Development application. Please note that the written application and narrative contain a
description of features to address many ordinance requirements which
will
need to be shown on
these land development Plans.
252 Brodhead Road Suite
1
Bethlehem PA 18017· 8944 610.691.5644· Fax 610.6 91.6 968 www.hanovereng.com
-
8/17/2019 Hanover Engineering Feb 15 Civil Engineer Report - Nestle Project in Eldred Township
2/5
Mary Anne Clausen
Eldred Township
ZO I G ORDINA CE:
2
February 15 2016
1.
Section 303 Water extraction/bottling is considered light manufacturing for the
purposes of the Zoning Ordinance.
2. Section 404.1 Light Manufacturing in the Commercial District
is
permitted by
Special Exception.
3.
Section 502.1.A
The
total number and type
of
uses must be identified on the
property. Two 2 or
more
principal buildings or uses located on a parcel in single
ownership shall conform to all the requirements of this Ordinance which would
normally apply to each building or use if each were
on
a separate district lot
including but not limited to setbacks parking lot coverage and sewage disposal
requirement
Each use should identify these features
as
if it was on its own separate
lot. This may include street frontage requirements such
as
Section 502.2 and
SALDO Section 606.3c.
4. Section 503.2 The height
of
all proposed fences shall
be
identified
on
the Plan to
verify compliance with this section.
5. Section 504.6.A Parking tabulations should be provided for each use in accordance
with
comment
three
3
above.
6. Section 504.7 Off street loading areas are required to be developed to street
construction standards. Section 607.10
of
the SALDO requires thicker paving
requirements than are proposed.
7. Section 504.7.H Fire Lanes should be identified on the Plan.
The
fire company
should
be
consulted
to
verify compliance with their accessibility requirements.
8. Section S04.8.C A Highway Occupancy Permit
vill
be required.
9.
Section 504.8.D Turning radius templates shall be provided to assure adequate
circulation for the expected vehicles at
ll
intersections and access points.
10. Section S04.9.B Parking spaces shall be located a minimum
of
10 feet from a
building wall.
11.
Section 504.15 Parking lots are required to be landscaped per Sections 701.1 and 2.
12.
Section 701.1 This section requires landscape buffers along any property with
existing residential use and any other boundary decided by the Township.
13. Section 701.1.B The residential buffer should
be
defined and dimensioned.
14.
Section 701.1.C The Plan must cl rify that the landscape buffer
will
provide a dense
screen within three 3 years per this section.
-
8/17/2019 Hanover Engineering Feb 15 Civil Engineer Report - Nestle Project in Eldred Township
3/5
Mary Anne Clausen
Eldred Township 3
Febmary 15, 2016
15. Section 701.8.C.3.d -
The
building elevations review or Sheet A-2.1 show wall pack
lighting mounted on the proposed building. is not clear if these
fL tures
are
accounted for
on
the Lighting Plan Sheet LL-1.
16. Section 701.11 -
The
application narrative states Consistent with state law Act 124
of 2009) and
NW
A policy, tanker trucks
w ll
not be allowed to idle their engines
when
not
engaged in vehicle movements . Are anyon-site measures/signage
proposed to prohibit idling of trucks?
17. Section 701.12 - A hydro-geologic study is required which clearly establishes tlliit the
proposed use will not cause a reduction
n
the quantity or the quality of ground water
supplies available to other properties located within 1000 feet
of
any portion
of
this
property. It is our understanding that the submitted study
is
under review by
another Township consultant.
18. Section 701.13 - Stormwater review comments are provided under the Stormwater
Management Ordinance section
of
t s letter and may be revisited during any future
land development plan review.
19. Section 701.15 - 0 D parking spaces have been shown.
20. Section 701.20 - nadequate and reliable water source shall
be
provided for
firefighting purposes. The Plan must identify the fire-fighting provisions proposed
the satisfaction of the Fire Department and Township.
21. Section 701.21 - The Applicant shall provide evidence that they have obtained all
required permits and authorizations.
22. Section 703.4 - An Environmental Impact Statement has been prepared. The
consultants must be previously approved by the Zoning Hearing Board.
23. Section 704.2 - 704.4 - Buffers for
all
on-site features shall be identified and
dimensioned.
24. Section 707.7 -
The
Township may wish to evaluate the future land use prohibitions
and special exceptions which may be introduced upon neighboring properties as a
result of the proposed.water supply wells. AI.so
e
se : age system for the existing
house should be identified and evaluated for lsolatlOn distance for wellhead
protection.
25. Section 708 -
The
following comments relate to the Traffic Impact Study TIS):
26. Section 708.C - The Intersection Sight Distance ISD) for all intersections reviewed
shall be revised in accordance with the AASTHO Green Book to account for the
posted speed limit not reduced truck speed), minor street approach grade, etc.
-
8/17/2019 Hanover Engineering Feb 15 Civil Engineer Report - Nestle Project in Eldred Township
4/5
Mary Anne Clausen
Eldred Township
February 15, 2016
27.
Section
7 8 C -
The Applicant shall provide a Table summarizing the sight distances
for all intersections analyzed.
28.
Section
7 8 C -
The Truck Route Study contained Appendix I refers to
structurally deficient
SD
and functionally obsolete FO) bridges; however, only
those with posted weight restrictions are called out.
The
Tables should be revised to
identify these bridges.
29. Section 708.3.B - The Trip Generation appears to be based on the average daily
,vater withdrawal volumes and capacity
of
the trucks. The study should also report
the maximum number of trucks that can be served during hours
of
operation as d ily
water withdrawal can be higher than the monthly average daily withdraw.
30. Section 708.3.B - The narrative references to HCS 2010 Sheet 11 should be
removed as Synchro 8 was used.
31. Section 708.3.B - The TIS shall include the volume capacity analysis of the
intersection
of
Silver Spring Blvd, SR 3003 and Kunkletown Road, SR 3004 as
requested by the Township following the Scoping Meeting with PennDOT.
32. Section 708.3.B - T he TIS should include the Saturday peak h ou r for peak hour s
analyzed.
33.
Section 1208.4 - The Planning Commission should review the standards and criteria
for special exceptions in this section.
STORMWATER rvfANAGEMENT ORDIN NCE
A Stormwater Management review
will
be performed
upon
receipt
of
the Land
Development application. We noted that the following items were not addressed
the stormwater
analysis provided:
1. The Plan identifies minimum stone envelopes around the infiltration trench, with
actual dimensions to be determined by the Designer. The Plan should clarify what
stone is proposed above and below the infiltration trench.
2. The Plan identifies an elevation of 523.5 near the bottom of the infiltration trench.
The Plan should clarify whether this
is
the bottom of the stone trench or the bottom
of
the SC-740 - Stormwater Facility.
3.
The Plan must clarify what filter fabric will be provided around the infiltration
trench.
4.
The
Designer must confirm that the widest orifice 4 ) will fit in the outlet control
structure, which
is
proposed to be a Type 1 Inlet Box.
S.
The Plan must show the infiltration test pit locations and limiting zones
on
a sheet
that shows the proposed infiltration system.
-
8/17/2019 Hanover Engineering Feb 15 Civil Engineer Report - Nestle Project in Eldred Township
5/5
Mary Anne Clausen
Eldred Township 5
February 15, 2016
6 The
erosion control details and construction sequence must provide for assuring that
no water enters the infiltration trench until the tributary area is completely stabilized
and the upstream storm sewer has been cleaned.
7.
The
Plan must make provisions to prevent conveyance
in
the trench outside
of
and
along the discharge pipe downstream of Inlet S-20 that might drain the infiltration
trench.
8 Means of access must be provided at ll bends n the storm sewer.
The Plan must clearly identify whether pavement
will
be graded to direct water to the
proposed inlets.
GENERAL COMMENTS:
The
Applicant shall verify that they have rights to cross any properties necessary to access
the public streets. The Applicant shall address any improvements required by PennDOT for
the access to Chestnut Ridge Drive (SR3001). Stone Arch Bridge Road (T-361) and its right
of-way
must
be labeled
on
the Plan, and the Applicant must provide ll frontage and
connection in1provements the Township would require.
Please note that the review
of
the application
is
ongoing and is, therefore subject to further
comment.
you have any questions or comments regarding this information, please contact this office.
Respectfully,
trnk:jam/jle
s:\PrOI \MunlCq,.I\E1dr.dT P\ E d 15-21-K leW Extr terion \Docs\20160215_,
G ASSOCIATES, INC.
cc: Attorney Paul Cohen
Eric Andreus