Page 1: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

GRUNDFOS DATA BOOKLET

AP, KPWastwater pumps

60 Hz

Page 2: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

2

Contents

General dataPerformance range Page 3Applications Page 4Examples of application Page 4Pump overview Page 5Type key for AP pumps Page 5Type key for KP pumps Page 5Construction Page 6Installation Page 6Sectional drawing Page 6

Performance curves Technical dataKP Page 7AP12 Page 10AP30 Page 14AP35 Page 18AP35B Page 22AP50 Page 25AP50B Page 29AP51 Page 32AP51 Vortex Page 36Control box Page 40AP80 Page 41APG Page 47

AccessoriesLC 107, LCD 107 Page 51LC 108, LCD 108 Page 52Level switches Page 53Accessories for AP, KP stainless steel pumps Page 54Accessories for cast iron AP pumps Page 55Level controllers and accessories Page 57Free-standing installation or portable Page 58Installation on auto-coupling Page 58Vertical dry installation (D) Page 58Level controllers and accessories Page 59Pipe dimensions Page 59

Product rangeKP Page 60AP12, AP30 Page 61AP35, AP35B, AP50, AP50B Page 62AP51, AP51 Vortex Page 63AP80, APG Page 64

Page 3: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

3

General data Wastewater pumpsAP, KP

Performance range

TM0

0 8

60

3 47

99

TM0

0 8

60

4 47

99

TM0

1 9

566

210

0

0 1 2 3 4 5 6 7 8 9 Q [l/s]

0

2

4

6

8

10

12

14

16

H[m]

0 8 16 24 32 Q [m³/h]

Drainage pumps

KP AP12

0 1 2 3 4 5 6 7 8 Q [l/s]

0

2

4

6

8

10

12

14

H[m]

0 8 16 24 Q [m³/h]

Wastewater andsewage pumps

AP50AP35

0 1 2 3 4 5 6 7 8 Q [l/s]

0

2

4

6

8

10

12

14

16

H[m]

0 8 16 24 Q [m³/h]

Wastewater andsewage pumps

AP50B

AP35B

TM0

0 8

60

2 47

99

TM0

0 8

60

5 47

99

TM0

1 77

18 2

100

0 2 4 6 8 10 12 14 16 18 Q [l/s]

0

4

8

12

16

20

24

28

H[m]

0 20 40 60 Q [m³/h]

Wastewater andsewage pumps

AP30

AP51

0 1 2 3 4 5 6 Q [l/s]

0

10

20

30

40

50

H[m]

0 5 10 15 20 Q [m³/h]

Grinder pumps

APG

0 5 10 15 20 25 30 35 40 45 50 Q [l/s]

0

5

10

15

20

25

30

H[m]

0 40 80 120 160 Q [m³/h]

Sewage pumps

AP80

Page 4: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

4

General data Wast

ewater pumpsAP, KP

ApplicationsThe KP and AP pumps are suitable for temporary as wellas permanent free-standing installation. FurthermoreAP pumps are suitable for installation on an auto-coupling at the bottom of a pit with guide rails going tothe top.

As an option the AP80 pumps are available for dry pitinstallation.

The pumps are designed for intermittent operation.

pH value for KP pumps: 4 to 9.pH value for AP pumps: 4 to 10.

Maximum density: 1.100 kg/m3.Maximum installation depth below water level: 10 m.

For permanent installation, level controllers are avail-able: LC for one-pump installations and LCD for two-pump installations.

Examples of application

KP

AP1

2

AP3

0

AP3

5

AP3

5B

AP5

0

AP5

0B

AP5

1

AP5

1V

ort

ex

AP8

0

APG

Max. liquid temperature 50°C 55°C 40°C 55°C 40°C 55°C 40°C 40°C 40°C 40°C 40°C

Pumping of wastewater from rivers and lakes ! ! ! ! ! ! " ! "

Pumping of drainage water and flood water ! ! ! ! ! ! ! " ! "

Pumping of surface rainwater ! ! ! ! ! ! ! ! ! "

Pumping of ditch and excavation drainage water ! ! ! ! ! ! ! !

Pumping of drainage water from garage sprinkler systems " ! " " " " ! " "

Mobile use for contractors, installers and industry ! ! ! ! ! ! ! ! "

Filling/emptying of containers ! ! ! ! ! ! ! ! !

Transfer of liquids in industry, etc. ! ! ! ! ! ! ! ! !

Pumping of effluents from tunnels, underground garages etc. ! ! ! ! ! ! ! ! !

Pumping of sewage from single and multi-family dwellings ! !

Pressurized pumping of sewage from camp sites, service areas and remote buildings !

Pressurized pumping of sewage from public buildings and small factories !

Pumping of sewage from private toilets, showers, swimming pools etc. below sewer level

! ! ! ! " !

Pumping of wastewater from single and multi-family homes, camp sites and sports stadiums

" " " ! !

Pumping of sewage in municipal applications ! !

Pumping of sewage from hotels, restaurants, cinemas, schools and public buildings ! !

Pumping of wastewater from underground stations and public swimming pools ! !

● = Recommended pump type❍ = Alternative pump type

Page 5: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

General data Wastew

ater pumpsAP, KP

Pump overview

Type key for AP pumps

Type key for KP pumps

Pump rangeFree passage

[mm]Impeller type Number of motor poles

KP 10 Semi-open 2

AP12 12 Semi-open 2

AP30 30 Open single-channel 2

AP35 35 Vortex 2

AP35B 35 Vortex 2

AP50 50 Vortex 2

AP50B 50 Vortex 2

AP51 50 Single-channel 2

AP51 Vortex 51 Vortex 2

AP80 80 Single-channel 4

APG grinder pumpsCutter system with semi-open impeller

2

Example AP 30 .50 .13 A 1 .V

AP: AP pump range

12-80:G:

Max. free passage [mm]With cutter system (APG grinder pumps)

B Basic

40-80: Nominal diameter of discharge port [mm]

0.4 - 107: Power output P2/100 [W]

A: With level switch

1: none or 3:

Single-phase voltage supplyThree-phase voltage supply

V: With vortex impeller

Example KP 150 A -1

KP: Pump range

150:250:

150 W motor power output250 W motor power output350 W motor power output350:

A:AV:M:

With float switchWith vertical level switchWithout level switch

1:3:

Single-phase voltage supplyThree-phase voltage supply

5

Page 6: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

6

General data Wast

ewater pumpsAP, KP

ConstructionVertical, single-stage, submersible centrifugal pumpswith horizontal or vertical discharge port designed forfree-standing installation or installation by means of anauto-coupling guide rail system or for pit installation.

The pumps are directly connected to an asynchronoussubmersible motor for

• 1 x 230 V ±10%, 60 Hz

• 3 x 230 V ±10%, 60 Hz

• 3 x 380 V ±10%, 60 Hz or

• 3 x 460 V ±10%, 60 Hz.

Enclosure class: IP 68.Insulation class: F (155°C).

Stainless steel pumps

Single-phase pumps incorporate thermal overloadprotection and require no additional motor protection.Three-phase pumps must be connected to a motorstarter.

Cast iron pumps

APG pumps have a built-in thermal protection whichcuts off the motor in case of overload. The motor restartsautomatically.

Some three-phase pumps have a thermal switch in themotor windings.

InstallationThe pumps are suitable for free-standing installation aswell as installation on an auto-coupling guide railsystem, which is available as an accessory.

Pumps in permanent submersible installations can beinstalled by means of a stationary auto-coupling at thebottom of the pit. Two guide rails going to the top of thepit ensure that the pump is positioned correctly whenlowered from the top of the pit down to the auto-coupling and connected to the pipe system. Due to thissystem, the pump can easily be pulled up for service.

For free-standing installation the AP80 and APG pumpsmust be fitted with a base stand, see accessories.

Sectional drawing

TM0

1 42

60

50

98

AP80.100.21

Page 7: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Technical data Dra

inage pumpsKP

KP

The KP pump is designed for liquid transfer and drainageof clean or slightly dirty wastewater with the pumpcompletely or partly submerged in the liquid.

• drainage of cellars or buildings,

• pumping of domestic wastewater without toilet waste,

• groundwater lowering,

• emptying applications, eg. in pools, tanks and vessels and

• pumping applications within agriculture, dairyindustry, horticulture and process industry.

ApprovalsZ-53.3-408 according to Institut für Bautechnik, Berlin.

Pumped liquidsPumps without level switch or with float switch:The pump is suitable for the pumping of

• clean, non-aggressive water and

• slightly dirty (grey) wastewater.

If the pump has been used for other liquids than cleanwater, it should be flushed through with clean waterimmediately after use. The open impeller constructionensures a free passage of solids up to a diameter of ø10mm.

Pumps with vertical level switch:The pump must only be used for the pumping of cleanground water and drain water.

Operating rangeInstallation depth: Max. 10 metres below liquid

level.Min. liquid temperature: 0°C.

Max. liquid temperature at continuous operation: 50°C.

During continuous pumping the suction strainer mustalways be completely covered by the liquid.

Max. liquid temperature: 70°C for periods not ex-ceeding 2 minutes at intervals of at least 30 minutes.

DischargeKP 150, KP 250 and KP 350: Rp 1¼.

Pump sleeve and housingSingle-stage, submersible, stainless steel, drainagepump in a robust design with upwards-pointingdischarge port placed on top of the pump.

The water enters the pump through the holes of thesuction strainer preventing the passage of large solids.The sturdy impeller has single curved vanes withbevelled front edges that prevent fibres from jammingthe impeller. The guide vanes in the pump housing notonly guide the liquid but also lift sand grains into theliquid flow and thus prevent blocking by sand.

The outer casing is made in one piece. The mains cableand the cable of the level switch are combined in onevulcanized and watertight plug, which is secured to thesocket of the hermetically sealed stator housing.

MotorThe motor is a single- or three-phase, asynchronouscanned motor with liquid-filled rotor chamber andwater lubricated bearings. The motor is cooled by thepumped liquid around the motor.

Enclosure class: IP 68.Insulation class: F.

The motor incorporates automatic overload protectionwhich cuts out the motor in case of overload. When ithas cooled to normal temperature, the motor will restartautomatically.

Note: The motors for 3 x 200 V do not incorporate over-load protection.

Materials

TM0

1 71

45 4

09

9

Components Materials DIN W.-Nr. AISI

Outer casing Stainless steel 1.4301 304

Pump housing Stainless steel 1.4301 304

Suction strainer Stainless steel 1.4301 304

Impeller Stainless steel 1.4301 304

Shaft Stainless steel 1.4057 431

Stator housing Stainless steel 1.4301 304

Guide vanes Stainless steel 1.4301 304

Bearings Carbon

O-rings Seal rings

NBR

Cables H07 RN-F

Performance curves Technical dataKP

7

Page 8: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

8

Technical data Dr

ainage pumpsKP

With float switch With vertical level switch

TM0

1 77

17 4

799

0 2 4 6 8 10 12 14 Q [m³/h]

0

1

2

3

4

5

6

7

8

9

10

H[m]

0 1 2 3 4 Q [l/s]

0

20

40

60

80

p[kPa]

KP60 Hz

KP 250

KP 150

KP350

Pump type VoltageP1

[W]p2

[W]In

[A]

Dimensions [mm] Weight[kg]H B1 B2 L1 L2 L3

KP 150 1 x 100 V 310 150 3.2 225 149 30 350# 400 70 6.3

KP 150 1 x 115 V 300 150 2.9 225 149 30 350# 400 70 6.3

KP 250 1 x 100 V 542 250 5.7 225 149 31 350# 400 70 7.2

KP 250 1 x 115 V 480 250 4.9 225 149 31 350# 400 70 7.2

KP 250 1 x 220 V 480 250 2.5 225 149 31 350# 400 70 7.2

KP 250 3 x 200 V 440 250 4.5 225 149 31 350# 400 70 7.2

KP 350 1 x 100 V 800 350 8.2 235 149 31 350# 410 70 8.0

KP 350 1 x 115 V 850 350 8.2 235 149 31 350# 410 70 8.0

KP 350 1 x 220 V 750 350 3.2 235 149 31 350# 410 70 8.0

KP 350 3 x 200 V 690 350 2.4 235 149 31 350# 410 70 8.0

# With vertical level switch : 250 mm.

TM0

0 1

803

159

7

1

2

H min

. L

min. L

min. L3

1

241

B

B

Rp 1 /

TM0

1 11

09

10

98

••

••

•••

••

• ••

••

••

••

••

• • •

•••

••

••

• •

••

••

••

•••

••

••

• •

• •

••

••

•••

••

• ••••

••

••

••

••

••

• • • •

• •

••

• •

••

••

•••

••

• ••••

••

••

••

••

••

• • • •

• •

••

• •••

••

••

••

••

••

• •

••

••

•••

••

••

••

••

••

••

• •

• ••

••

••

••

••

••

••

••

••

• •

••

••

••

••

ø 250 mm

400 mm

Page 9: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Technical data Dra

inage pumpsKP

InstallationPumps without level switch or with float switch can beused in vertical position with the discharge port upper-most or in horizontal or tilted position with thedischarge port as the highest point of the pump.

Pumps with vertical level switch must be used in verticalposition.

The KP pump is well suited for permanent installation.

Level switchesA level switch, which gives impulses to start/stopbetween two levels of liquid, is connected to pumpsintended for automatic operation. This type of installa-tion requires a non-return valve in the discharge pipe orin the pump. The pumps are available with two differenttypes of level switches.

Min. liquid level: – manual operation: 14 mm.– automatic operation: See below.

Pumps with float switch:

A clamp on the handle of the pump holds the cable of thelevel switch. The difference in level between start andstop can be adjusted by changing the free cable lengthbetween the handle of the pump and the level switch.

Dimensions for KP 350 are marked with "#".

Pumps with vertical level switch:

For pumps with vertical level switch, the difference inlevel between start and stop is not adjustable.

Dimensions for KP 350 are marked with "#".

TM0

0 1

548

049

3TM

00

149

2 46

97

TM0

0 1

552

259

9TM

01

110

8 32

97

•• • • • • • • • • • • • •• • • • • • • • • • • •• • • • • • • • • • •• • • • • • • • • • • •• • • • • • • • • • •• • • • • • • • • •• • • • • • • • • • •• • • • • • • • • •• • • • • • • • • •• • • • • • • • • •• • • • • • • • •• • • • • • • •• • • • • • • •• • • • • • • •

Max.150mm

Start

Stop

100mm

225mm

Float switch

100 mm110 mm#

225 mm

Max. 150 mm

Start

Stop80 mm

100 mm

80 mm

100 mm110 mm#

Vertical level switch

9

Page 10: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

10

Technical data

AP12

AP12

The AP12 pump is a single-stage submersible pumpdesigned for the pumping of drainage water. The pumpis suitable for the following applications

• ground water lowering,

• pumping in drainage pits,

• pumping in surface water pits with inflow from roof gutters, shafts, tunnels, etc.,

• emptying of ponds, tanks, etc. and

• maximum particle size: 12 mm.

ApprovalsPA-I no. 4104 VDE.

Automatic operationThe pump is available for automatic as well as manualoperation and can be installed in a permanent installa-tion or used as a portable pump. The pump is available:

• with level switch fitted for automatic ON/OFF opera-tion between two liquid levels (single-phase pumps);

• with separate level switch and control box for auto-matic ON/OFF operation between two liquid levels (three-phase pumps);

• without level switch for manual ON/OFF operation.

Pumps fitted with level switches can also be used formanual ON/OFF operation. In this case the level switchmust be secured in an upwards-pointing position.

Pump sleeve and housingThe stainless steel pump sleeve is made in one piece andequipped with an insulated carrying handle. The suctionstrainer is clipped on to the pump housing and can easilybe removed for maintenance. The strainer not onlyprevents the passage of large solids but also ensures aslow flow into the pump. As a result, most impuritieswill be deposited outside the pump.

The stainless steel pump housing is fitted with aninternal riser pipe ensuring high efficiency. The riser pipehas a number of holes which enable efficient cooling ofthe motor during operation. The cable entry is of thesocket and plug connection type, which makes quick andeasy dismantling possible.

Discharge portAll AP12 pumps have a threaded vertical dischargeport.

AP12.40: Rp 1½.AP12.50: Rp 2.

Shaft and bearingsThe shaft is made of stainless steel and rotates in main-tenance-free prelubricated ball bearings.

ImpellerThe stainless steel impeller is a semi-open impeller withL-shaped blades and a clearance of 12 mm. The bladesare curved backwards to reduce any harmful effect fromsolid particles and to reduce the power consumption.

Shaft sealThe shaft seal is a combination of a mechanical shaftseal of the bellows type and a lip seal with 60 ml oilbetween them. The mechanical shaft seal of AP12 pumpshas silicone carbide seal faces.

Motor cableStandard pumps 10 m: H07RNF.

Materials

TM0

0 5

738

089

5

TM0

0 5

477

400

0

Description Materials DIN W.-Nr. AISI

Pump housing Stainless steel 1.4301 304

Riser pipe Stainless steel 1.4301 304

Impeller Stainless steel 1.4301 304

Pump sleeve Stainless steel 1.4401 316

Shaft Stainless steel 1.4305

Bearings Heavy-duty prelubricated ball bearings

O-rings NBR rubber

Screws Stainless steel 1.4301 304

Oil Shell Ondina 15, non-toxic

Page 11: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Performance curves

AP12

TM0

0 7

213

479

9

0 5 10 15 20 25 30 35 Q [m³/h]

0.0

0.4

0.8

1.2

1.6

2.0

[kW]P1

0.0

0.8

1.6

2.4

P1[hp]

.40.04.1

.40.06.1

.40.06.3

.40.08.1

.40.08.3

.50.11.1

.50.11.3

0 5 10 15 20 25 30 35 Q [m³/h]

0

2

4

6

8

10

12

14

16

[m]H

0 2 4 6 8 10 Q [l/s]

0

40

80

120

160

p[kPa] AP12

60 HzISO 9906 +/- 10%

.40.04

.40.06.1.40.06.3

.40.08.1.40.08.3

.50.11.1.50.11.3

11

Page 12: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

12

Technical data

AP12

.8

.8

6

6

0

0

0

0

.2

.2

.3

.3

.3

.3

.7

.7

9

9

9

9

TM0

0 5

523

09

95

S

B

A

Pump type VoltageP1

[kW]p2

[kW]In

[A]Cos ϕ

Dimensions [mm]Weight

[kg]A B S

AP12.40.04.1 1 x 220 - 230 V 0.8 0.4 3.7 0.99 6.0 321 216 Rp 1½ 10.0 - 10

AP12.40.04.A1 1 x 220 - 230 V 0.8 0.4 3.7 0.99 6.0 321 216 Rp 1½ 10.0 - 10

AP12.40.04.3 3 x 200 - 220 V 0.8 0.4 2.4 0.91 6.0 321 216 Rp 1½ 9.7 - 12.0

AP12.40.04.A3 3 x 200 - 220 V 0.8 0.4 2.4 0.91 6.0 321 216 Rp 1½ 9.7 - 12.0

AP12.40.04.3 3 x 380 - 400 V 0.8 0.4 1.1 0.83 6.0 321 216 Rp 1½ 9.7 - 12.0

AP12.40.04.A3 3 x 380 - 400 V 0.8 0.4 1.1 0.83 6.0 321 216 Rp 1½ 9.7 - 12.0

AP12.40.06.1 1 x 220 - 230 V 1.0 0.6 4.4 0.99 3.8 321 216 Rp 1½ 10.8 - 11.

AP12.40.06.A1 1 x 220 - 230 V 1.0 0.6 4.4 0.99 3.8 321 216 Rp 1½ 10.8 - 11.

AP12.40.06.3 3 x 200 - 220 V 1.0 0.6 3.2 0.91 6.0 321 216 Rp 1½ 10.7 - 13.

AP12.40.06.A3 3 x 200 - 220 V 1.0 0.6 3.2 0.91 6.0 321 216 Rp 1½ 10.7 - 13.

AP12.40.06.3 3 x 380 - 400 V 0.9 0.6 1.5 0.83 6.0 321 216 Rp 1½ 10.7 - 13.

AP12.40.06.A3 3 x 380 - 400 V 0.9 0.6 1.5 0.83 6.0 321 216 Rp 1½ 10.7 - 13.

AP12.40.08.1 1 x 220 - 230 V 1.3 0.8 5.9 0.99 3.8 346 216 Rp 1½ 12.4 - 13

AP12.40.08.A1 1 x 220 - 230 V 1.3 0.8 5.9 0.99 3.8 346 216 Rp 1½ 12.4 - 13

AP12.40.08.3 3 x 200 - 220 V 1.2 0.8 3.9 0.91 6.0 346 216 Rp 1½ 12.0 - 14

AP12.40.08.A3 3 x 200 - 220 V 1.2 0.8 3.9 0.91 6.0 346 216 Rp 1½ 12.0 - 14

AP12.40.08.3 3 x 380 - 440 V 1.2 0.8 1.8 0.87 6.0 346 216 Rp 1½ 12.0 - 14

AP12.40.08.A3 3 x 380 - 440 V 1.2 0.8 1.8 0.87 6.0 346 216 Rp 1½ 12.0 - 14

AP12.50.11.1 1 x 220 - 230 V 1.8 1.1 9.0 0.98 6.0 357 241 Rp 2 14.9 - 15

AP12.50.11.A1 1 x 220 - 230 V 1.8 1.1 9.0 0.98 6.0 357 241 Rp 2 14.9 - 15

AP12.50.11.3 3 x 200 - 220 V 1.6 1.1 5.9 0.85 6.0 357 241 Rp 2 15.6 - 17.

AP12.50.11.A3 3 x 200 - 220 V 1.6 1.1 5.9 0.85 6.0 357 241 Rp 2 15.6 - 17.

AP12.50.11.3 3 x 380 - 440 V 1.8 1.1 2.7 0.88 6.0 357 241 Rp 2 15.6 - 17.

AP12.50.11.A3 3 x 380 - 440 V 1.8 1.1 2.7 0.88 6.0 357 241 Rp 2 15.6 - 17.

Istart

In---------

Page 13: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Technical data

AP12

AP12 installations

TM0

0 5

538

09

95

min. ø500

TM0

0 5

539

09

95

min. ø800

13

Page 14: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

14

Technical data

AP30

AP30

The pumps are used for pumping wastewater, sludge-containing water, ground water and surface water inplaces such as

• holiday homes,

• single-family houses,

• blocks of flats,

• public buildings,

• factories,

• garages,

• underground car parks and

• car wash areas.

Applications as under AP12, but where a larger impellerclearance is required.

Pump and stator housingThe pump housing and the stator housing are made ofcast iron.

The stator housing is dry, i.e. not oil-filled.

DischargeAll AP30 pumps have a horizontal R 2 discharge port forthreaded connection.

Shaft and bearingsThe shaft is made of stainless steel and rotates in main-tenance-free prelubricated ball bearings.

ImpellerThe impeller is a vortex impeller in cast iron GG 25 witha free passage of 30 mm in the pump housing. Cast ironis chosen as it is resistant towards mechanicallywearing particles.

Shaft sealCombination of mechanical shaft seal and lip seal.

The primary shaft seal have silicon carbide/siliconcarbide seal faces.The secondary shaft seal is a lip seal. The chamberbetween the shaft seals is filled with oil.

Standard pumps: 0.01 litre

Motor cableStandard pumps 10 m: H07RNF.

Materials

Control boxFurther information about control box, float switch, andlevel controller, see page 40.

TM0

1 71

74 4

09

9

TM0

1 26

17 2

09

8

Description Materials DIN W.-Nr. AISI/ASTM

Stator housing Cast iron GG 25 0.6025 ASTM 35B

Pump housing Cast iron GG 25 0.6025 ASTM 35B

Neck ring Bronze

Impeller Cast iron GG 25 0.6025 ASTM 35B

Wear plate Cast iron GG 25 0.6025 ASTM 35B

Shaft Stainless steel 1.4104 AISI 430F

Bearings Heavy-duty prelubricated ball bearings

Screws Stainless steel 1.4301 AISI 304

Oil Shell Ondina 15, non-toxic

Page 15: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Performance curves

AP30

TM0

0 7

215

479

9

0 5 10 15 20 25 30 35 Q [m³/h]

0.0

0.4

0.8

1.2

1.6

2.0

[kW]P1

0.0

0.8

1.6

2.4

P1[hp]

09.1.V

09.3.V

14.3.V13.1.V

0 5 10 15 20 25 30 35 Q [m³/h]

0

1

2

3

4

5

6

7

8

9

10

11

12

[m]H

0 2 4 6 8 10 Q [l/s]

0

20

40

60

80

100

p[kPa] AP30.50.

60 HzISO 2548 Annex B

09.1.V

09.3.V

13.1.V

14.3.V

15

Page 16: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

16

Technical data

AP30

Elbow is an accessory

TM0

1 25

50 2

09

8

S

A

E

B

C

D

Pump type VoltageP1

[kW]P2

[kW]n

[min-1]In

[A]Cos ϕ

Dimensions [mm]Weight

[kg]A B C D E S

AP30.50.09.1.V 1 x 230 V 1.2 0.9 3450 5.4 0.97 3.4 431 312 101 51 175 R 2 26 - 27

AP30.50.09.A1.V 1 x 230 V 1.2 0.9 3450 5.4 0.97 3.4 431 312 101 51 175 R 2 26 - 27

AP30.50.09.3.V 3 x 230 V 1.2 0.9 3450 4.0 0.79 6.0 431 312 101 51 175 R 2 25

AP30.50.09.3.V 3 x 380 V 1.2 0.9 3450 2.3 0.79 6.0 431 312 101 51 175 R 2 25

AP30.50.09.3.V 3 x 460 V 1.2 0.9 3450 1.9 0.79 6.0 431 312 101 51 175 R 2 25

AP30.50.13.1.V 1 x 230 V 1.8 1.3 3450 7.8 0.97 6.0 431 312 101 51 175 R 2 26 - 27

AP30.50.13.A1.V 1 x 230 V 1.8 1.3 3450 7.8 0.97 6.0 431 312 101 51 175 R 2 26 - 27

AP30.50.14.3.V 3 x 230 V 1.8 1.4 3450 5.6 0.84 6.0 431 312 101 51 175 R 2 25

AP30.50.14.3.V 3 x 380 V 1.8 1.4 3450 3.3 0.84 6.0 431 312 101 51 175 R 2 25

AP30.50.14.3.V 3 x 460 V 1.8 1.4 3450 2.7 0.84 6.0 431 312 101 51 175 R 2 25

Istart

In---------

Page 17: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Technical data

AP30

AP30 installations

One-pump installation on auto-coupling

Two-pump installation on auto-coupling

TM0

1 25

51 2

09

8

‹ ‹

‹‹

‹‹

‹‹

‹‹

‹‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹ ‹

‹‹

‹‹‹

‹‹

‹ ‹‹

‹‹

‹ ‹‹‹ ‹

‹‹

‹‹‹

‹‹

‹‹

‹‹

‹‹‹

‹‹

‹ ‹

‹‹

‹‹

‹‹

‹‹

F

C

A

U

Z

J

G

K L

N O

T

E

S

TM0

1 25

52 2

09

8

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹ ‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

D

I

M M

R PP

B

Pump type A B C D E F G I J K L M N O P S T U Z

AP30.50.09.1.V ø600 ø600 265 300 45 45 65 115 108 150 400 200 300 700 500 Rp 2 ½" 160 295

AP30.50.09.A1.V ø600 ø600 265 300 45 45 65 115 108 150 400 200 300 700 500 Rp 2 ½" 160 295

AP30.50.09.3.V ø600 ø600 265 300 45 45 65 115 108 150 400 200 300 700 500 Rp 2 ½" 160 295

AP30.50.13.1.V ø600 ø600 265 300 45 45 65 115 108 150 400 200 300 700 500 Rp 2 ½" 160 295

AP30.50.13.A1.V ø600 ø600 265 300 45 45 65 115 108 150 400 200 300 700 500 Rp 2 ½" 160 295

AP30.50.14.3.V ø600 ø600 265 300 45 45 65 115 108 150 400 200 300 700 500 Rp 2 ½" 160 295

Pump type A B C D E F G I J K L M N O P R S T U Z

AP30.50.09.1.V 455 600 265 135 45 45 65 115 108 150 400 200 300 700 335 330 Rp 2 ½" 160 295

AP30.50.09.A1.V 455 600 265 135 45 45 65 115 108 150 400 200 300 700 335 330 Rp 2 ½" 160 295

AP30.50.09.3.V 455 600 265 135 45 45 65 115 108 150 400 200 300 700 335 330 Rp 2 ½" 160 295

AP30.50.13.1.V 455 600 265 135 45 45 65 115 108 150 400 200 300 700 335 330 Rp 2 ½" 160 295

AP30.50.13.A1.V 455 600 265 135 45 45 65 115 108 150 400 200 300 700 335 330 Rp 2 ½" 160 295

AP30.50.14.3.V 455 600 265 135 45 45 65 115 108 150 400 200 300 700 335 330 Rp 2 ½" 160 295

17

Page 18: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

18

Technical data

AP35

AP35

The AP35 pump is a single-stage submersible pumpdesigned for the pumping of drainage water andeffluent.The pump is suitable for the following applications

• ground water lowering,

• pumping in drainage pits,

• pumping in surface water pits with inflow from roof gutters, shafts, tunnels, etc.,

• emptying of ponds, tanks, etc.,

• pumping of fibre-containing wastewater from laun-dries and industries and

• pumping of domestic wastewater without discharge from water closets.

ApprovalsPA-I no. 4104 VDE.

Automatic operationThe pump is available for automatic as well as manualoperation and can be installed in a permanent installa-tion or used as a portable pump. The pump is available:

• with level switch fitted for automatic ON/OFF opera-tion between two liquid levels (single-phase pumps);

• with separate level switch and control box for auto-matic ON/OFF operation between two liquid levels (three-phase pumps);

• without level switch for manual ON/OFF operation.

Pumps fitted with level switches can also be used formanual ON/OFF operation. In this case the level switchmust be secured in an upwards-pointing position.

Pump sleeve and housingThe stainless steel pump sleeve is made in one piece andequipped with an insulated carrying handle. The suctionstrainer is clipped on to the pump housing and can easilybe removed for maintenance.

The strainer not only prevents the passage of large solidsbut also ensures a slow flow into the pump.

The stainless steel pump housing is fitted with aninternal riser pipe ensuring high efficiency. The riser pipehas a number of holes which enable efficient cooling ofthe motor during operation. The cable entry is of thesocket and plug connection type, which makes quick andeasy dismantling possible.

Discharge portAll AP35 pumps have a threaded vertical discharge port:Rp 1½.

Shaft and bearingsThe shaft is made of stainless steel and rotates in main-tenance-free prelubricated ball bearings.

ImpellerThe stainless steel impeller is a Vortex impeller withL-shaped blades and a clearance of 35 mm (in the pumphousing). The blades are curved backwards to reduce anyharmful effect from solid particles and to reduce thepower consumption.

Shaft sealThe shaft seal is a combination of a mechanical shaftseal of the bellows type and a lip seal with 60 ml oilbetween them. The shaft seal has silicon carbide sealfaces.

Motor cableStandard pumps 10 m: H07RNF.

Materials

TM0

0 5

739

119

5

TM0

0 5

478

400

0

Description Materials DIN W.-Nr. AISI

Pump housing Stainless steel 1.4301 304

Riser pipe Stainless steel 1.4301 304

Impeller Stainless steel 1.4301 304

Pump sleeve Stainless steel 1.4401 316

Shaft Stainless steel 1.4305

Bearings Heavy-duty prelubricated ball bearings

O-rings NBR rubber

Screws Stainless steel 1.4301 304

Cables Neoprene

Oil Shell Ondina 15, non-toxic

Page 19: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Performance curves

AP35

TM0

0 7

220

479

9

0 2 4 6 8 10 12 14 16 18 20 Q [m³/h]

0

1

2

3

4

5

6

7

8

9

10

11

12

13

H[m]

0 1 2 3 4 5 6 Q [l/s]

0

20

40

60

80

100

120

p[kPa] AP35.40.

60 HzISO 9906 Annex A

06.1.V

06.3.V

08.1.V

08.3.V

0 2 4 6 8 10 12 14 16 18 20 Q [m³/h]

0.0

0.2

0.4

0.6

0.8

1.0

1.2

P1[kW]

0.0

0.5

1.0

1.5

P1[hp]

08.3.V

08.1.V

06.3.V

06.1.V

TM00

722

0 45

00

19

Page 20: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

20

Technical data

AP35

TM0

0 5

524

09

95

S

B

A

Pump type VoltageP1

[kW]P2

[kW]In

[A]Cos ϕ

Dimensions [mm]Weight

[kg]A B S

AP35.40.06.1.V 1 x 220 - 230 V 1.2 0.7 3.9 0.97 6.0 376 216 Rp 1½ 11.2 - 12.0

AP35.40.06.A1.V 1 x 220 - 230 V 1.2 0.7 3.9 0.97 6.0 376 216 Rp 1½ 11.2 - 12.0

AP35.40.06.3.V 3 x 200 - 220 V 1.1 0.6 3.2 0.91 6.0 376 216 Rp 1½ 11.1 - 13.4

AP35.40.06.A3.V 3 x 200 - 220 V 1.1 0.6 3.2 0.91 6.0 376 216 Rp 1½ 11.1 - 13.4

AP35.40.06.3.V 3 x 380 - 400 V 1.1 0.7 1.4 0.86 6.0 376 216 Rp 1½ 11.1 - 13.4

AP35.40.06.A3.V 3 x 380 - 400 V 1.1 0.7 1.4 0.86 6.0 376 216 Rp 1½ 11.1 - 13.4

AP35.40.08.1.V 1 x 220 - 230 V 1.3 0.9 5.3 0.98 6.0 410 216 Rp 1½ 12.5 - 13.3

AP35.40.08.A1.V 1 x 220 - 230 V 1.3 0.9 5.3 0.98 6.0 410 216 Rp 1½ 12.5 - 13.3

AP35.40.08.3.V 3 x 200 - 220 V 1.1 0.7 3.6 0.85 4.8 410 216 Rp 1½ 12.1 - 14.4

AP35.40.08.A3.V 3 x 200 - 220 V 1.1 0.7 3.6 0.85 4.8 410 216 Rp 1½ 12.1 - 14.4

AP35.40.08.3.V 3 x 380 - 400 V 1.1 0.7 2.0 0.86 5.2 410 216 Rp 1½ 12.1 - 14.4

AP35.40.08.A3.V 3 x 380 - 400 V 1.1 0.7 2.0 0.86 5.2 410 216 Rp 1½ 12.1 - 14.4

Istart

In---------

Page 21: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Technical data

AP35

AP35 installations

TM0

0 5

935

389

8

••••

• • •

••

• •

• ••

••

• ••

• ••

••

••

••

••

••

•••

• •

••

••

••

•••

••

• •

• •

•••

••

••

••

min. ø500

TM0

0 5

936

389

8

••

••

••

••

••

••

••

••

••

••

••

••

• ••

•• •

• ••

••

••

••

••

••

••

• ••

••

• ••

• ••

•••

min. ø800

21

Page 22: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

22

Technical data

AP35B

AP35B

The AP35B pump is a single-stage submersible pumpdesigned for pumping effluent.

The pump is suitable for:

• groundwater lowering,

• pumping in drainage pits,

• pumping in surface water pits with inflow from roof gutters, shafts, tunnels, etc.,

• emptying of ponds, tanks, etc.,

• pumping of fibre-containing effluent from laundries and industries,

• pumping of domestic effluent from septic tanks and sludge treating systems,

• pumping of domestic effluent without discharge from water closets.

Automatic operationThe pump is available for automatic as well as manualoperation and can be installed in a permanent installa-tion or used as a portable pump.

The pump is available:

• with level switch fitted for automatic ON/OFF opera-tion between two liquid levels (single-phase pumps);

• without level switch for manual ON/OFF operation.

Pumps fitted with level switches can also be used formanual ON/OFF operation. In this case the level switchmust be secured in an upwards-pointing position.

Pump housingPump housing with an outstanding design for submers-ible wastewater pumps resulting in a high head.

The pump housing is made of a steel tube with a smoothsurface and a hydraulically correct shape ensuring freepassage of particles.

Base, pump inlet and pump housing are fastened to themotor by means of 4 springs enabling quick and easydismantling.

Discharge portAll AP35B pumps have a threaded horizontal dischargeport: Rp 2.

Shaft and bearingsThe shaft is made of stainless steel and rotates in main-tenance-free prelubricated ball bearings.

ImpellerThe stainless steel impeller is a Vortex impeller withL-shaped blades and a clearance of 35 mm (in the pumphousing). The blades are curved backwards to reduce anyharmful effect from solid particles and to reduce thepower consumption. The impeller has a protective cap toprevent the deposits of long-fibred material.

Shaft sealThe shaft seal is a combination of a mechanical shaftseal of the bellows type and a lip seal with 80 ml oilbetween them. The shaft seal has silicon carbide sealfaces.

Materials

TM0

1 41

87 4

99

8

TM0

0 5

478

400

0

Description Materials DIN

W.-Nr. AISI

Pump housing Stainless steel 1.4301 304

Impeller Stainless steel 1.4301 304

Washer Stainless steel 1.4301 304

Protective cap Novolen 2360 Kx

Motor unit completeParts in contact with liquid:Stainless steel

1.4401 316

Shaft with rotor Stainless steel/silumin 1.4305

Motor cable Neoprene

O-rings NBR rubber

Spring Stainless steel 1.4310

Pump inlet Stainless steel 1.4301 304

Base Polycarbonate

Oil Shell Ondina 15, non-toxic

Page 23: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Technical data

AP35B

TM0

1 35

81 4

498

0 5 10 15 20 Q [m³/h]0

2

4

6

8

10

12

14

H[m]

0 1 2 3 4 5 6 Q [l/s]

0

20

40

60

80

100

120

140

p[kPa] AP35B

60 HzISO 9906 Annex A

AP35B.50.06.1AP35B.50.08.1

0 5 10 15 20 Q [m³/h]0.0

0.4

0.8

1.2

1.6

P 1[kW]

0.0

0.5

1.0

1.5

2.0

P 1[hp]

AP35B.50.06.1AP35B.50.08.1

TM0

1 9

219

150

0

D

A

C

S

Pump type VoltageP1

[kW]In

[A]Cos ϕ

Dimensions [mm]Weight

[kg]A C D S

AP35B.50.06.1.V 1 x 220-230 V 1.29 5.91 0.99 3.05 443 116 73 R2 8.5

AP35B.50.06.A1.V 1 x 220-230 V 1.29 5.91 0.99 3.05 443 116 73 R2 8.5

AP35B.50.06.3.V 3 x 200-220 V 1.21 3.71 0.94 4.39 443 116 73 R2 7.5

AP35B.50.08.1.V 1 x 220-230 V 1.47 6.74 0.99 3.59 468 116 73 R2 10.1

AP35B.50.08.A1.V 1 x 220-230 V 1.47 6.74 0.99 3.59 468 116 73 R2 10.1

AP35B.50.08.3.V 3 x 200-220 V 1.48 4.5 0.94 4.87 468 116 73 R2 8.5

Istart

In---------

23

Page 24: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

24

Technical data

AP35B

AP35B installations

One-pump installation on auto-coupling

Two-pump installation on auto-coupling

TM0

1 35

93

449

8

••

• •

••

••

••

••

•••

••

••

••

••

••

••

••

• •

••

••

•••

••

• ••

••

• ••• •

••

•••

••

••

••

••

•••

••

• •

••

••

••

••

F

C

A

U

Z J

G

K L

N O

T

E

S

TM0

1 35

93

449

8

••

••

••

••

••

••

••

••

••

• •

••

••

••

••

••

••

D

I

M M

R PP

B

Pump typeDimensions [mm]

A B C D E F G I J K L M N O P R S T U Z

AP35B.50.06.1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261

AP35B.50.06.A1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261

AP35B.50.06.3.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261

AP35B.50.08.1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261

AP35B.50.08.A1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261

AP35B.50.08.3.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261

Pump typeDimensions [mm]

A B C D E F G I J K L M N O P R S T U Z

AP35B.50.06.1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261

AP35B.50.06.A1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261

AP35B.50.06.3.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261

AP35B.50.08.1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261

AP35B.50.08.A1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261

AP35B.50.08.3.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261

Page 25: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Technical data

AP50

AP50

The AP50 pump is a single-stage submersible pumpdesigned for the pumping of effluent and sewage. Thepump is suitable for the following applications

• ground water lowering,

• pumping in drainage pits,

• pumping in surface water pits with inflow from roof gutters, shafts, tunnels, etc.,

• emptying of ponds, tanks, etc.,

• pumping of fibre-containing wastewater from laun-dries and industries,

• pumping of domestic wastewater from septic tanks and sludge treating systems and

• pumping of domestic wastewater with/without dis-charge from water closets.

ApprovalsPA-I no. 4104 and VDE.

Automatic operationThe pump is available for automatic as well as manualoperation and can be installed in a permanent installa-tion or used as a portable pump. The pump is available:

• with level switch fitted for automatic ON/OFF opera-tion between two liquid levels (single-phase pumps);

• with separate level switch and control box for auto-matic ON/OFF operation between two liquid levels (three-phase pumps);

• without level switch for manual ON/OFF operation

Pumps fitted with level switches can also be used formanual ON/OFF operation. In this case the level switchmust be secured in an upwards-pointing position.

Pump sleeve and housingThe stainless steel pump sleeve is made in one piece andequipped with an insulated carrying handle.

The suction strainer is clipped on to the pump housingand can easily be removed for maintenance. The strainernot only prevents the passage of large solids but alsoensures a slow flow into the pump.

The stainless steel pump housing is fitted with aninternal riser pipe ensuring high efficiency. The riser pipehas a number of holes which enable efficient cooling ofthe motor during operation. The cable entry is of thesocket and plug connection type, which makes quick andeasy dismantling possible.

Discharge portAll AP50 pumps have a threaded vertical discharge port:Rp 2.

Shaft and bearingsThe shaft is made of stainless steel and rotates in main-tenance-free prelubricated ball bearings.

ImpellerThe stainless steel impeller is a Vortex impeller withL-shaped blades and a clearance of 50 mm (in the pumphousing). The blades are curved backwards to reduce anyharmful effect from solid particles and to reduce thepower consumption. The impeller has a protective cap toprevent the deposits of long-fibred material.

Shaft sealThe shaft seal is a combination of a mechanical shaftseal of the bellows type and a lip seal with 60 ml oilbetween them. The shaft seal has silicon carbide sealfaces.

Motor cableStandard pumps 10 m: H07RNF.

Materials

TM0

0 5

740

149

5

TM0

0 5

477

400

0

Description Materials DIN W.-Nr. AISI

Pump housing Stainless steel 1.4301 304

Riser pipe Stainless steel 1.4301 304

Impeller Stainless steel 1.4301 304

Pump sleeve Stainless steel 1.4401 316

Shaft Stainless steel 1.4305

Bearings Heavy-duty prelubricated ball bearings

O-rings NBR rubber

Screws Stainless steel 1.4301 304

Cables Neoprene

Oil Shell Ondina 15, non-toxic

25

Page 26: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

26

Performance curves

AP50

TM0

0 7

218

419

9

0 4 8 12 16 20 24 28 32 Q [m³/h]

0

1

2

3

4

5

6

7

8

9

10

11

12

13

H[m]

0 2 4 6 8 10 Q [l/s]

0

20

40

60

80

100

120

p[kPa] AP50.50.

60 HzISO 9906 Annex A

08.1.V08.3.V 11.1.V11.3.V

0 4 8 12 16 20 24 28 32 Q [m³/h]

0.0

0.4

0.8

1.2

1.6

2.0

P1[kW]

0.0

0.8

1.6

2.4

P1[hp]

11.V

08.V

TM00

721

8 45

00

Page 27: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Technical data

AP50

TM0

0 5

524

09

95

S

B

A

Pump type VoltageP1

[kW]P2

[kW]In

[A]Cos ϕ

Dimensions [mm]Weight

[kg]A B S

AP50.50.08.1.V 1 x 220 - 230 V 1.4 1.0 6.3 0.98 6.0 436 241 Rp 2 14.9 - 15.7

AP50.50.08.A1.V 1 x 220 - 230 V 1.4 1.0 6.3 0.98 6.0 436 241 Rp 2 14.9 - 15.7

AP50.50.08.3.V 3 x 200 - 220 V 1.4 0.9 4.0 0.85 6.0 436 241 Rp 2 14.2 - 16.5

AP50.50.08.A3.V 3 x 200 - 220 V 1.4 0.9 4.0 0.85 6.0 436 241 Rp 2 14.2 - 16.5

AP50.50.08.3.V 3 x 380 - 440 V 1.4 1.0 2.1 0.85 6.0 436 241 Rp 2 14.2 - 16.5

AP50.50.08.A3.V 3 x 380 - 440 V 1.4 1.0 2.1 0.85 6.0 436 241 Rp 2 14.2 - 16.5

AP50.50.11.1.V 1 x 220 - 230 V 1.8 1.2 8.4 0.98 6.0 436 241 Rp 2 14.9 - 15.7

AP50.50.11.A1.V 1 x 220 - 230 V 1.8 1.2 8.4 0.98 6.0 436 241 Rp 2 14.9 - 15.7

AP50.50.11.3.V 3 x 200 - 220 V 1.6 1.2 6.0 0.85 2.9 436 241 Rp 2 15.6 - 17.9

AP50.50.11.A3.V 3 x 200 - 220 V 1.6 1.2 6.0 0.85 2.9 436 241 Rp 2 15.6 - 17.9

AP50.50.11.3.V 3 x 380 - 440 V 1.6 1.6 3.0 0.88 4.9 436 241 Rp 2 15.6 - 17.9

AP50.50.11.A3.V 3 x 380 - 440 V 1.6 1.6 3.0 0.88 4.9 436 241 Rp 2 15.6 - 17.9

Istart

In---------

27

Page 28: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

28

Technical data

AP50

AP50 installations

TM0

0 5

935

389

8

••••

• • •

••

• •

• ••

••

• ••

• ••

••

••

••

••

••

•••

• •

••

••

••

•••

••

• •

• •

•••

••

••

••

min. ø500

TM0

0 5

936

389

8

••

••

••

••

••

••

••

••

••

••

••

••

• ••

•• •

• ••

••

••

••

••

••

••

• ••

••

• ••

• ••

•••

min. ø800

Page 29: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Technical data

AP50B

AP50B

The AP50B pump is a single-stage submersible pumpdesigned for the pumping effluent.

The pump is suitable for:

• groundwater lowering,

• pumping in drainage pits,

• pumping in surface water pits with inflow from roof gutters, shafts, tunnels, etc.,

• emptying of ponds, tanks, etc.,

• pumping of fibre-containing effluent from laundries and industries,

• pumping of domestic effluent from septic tanks and sludge treating systems,

• pumping of domestic effluent without discharge from water closets.

Automatic operationThe pump is available for automatic as well as manualoperation and can be installed in a permanent installa-tion or used as a portable pump.

The pump is available:

• with level switch fitted for automatic ON/OFF opera-tion between two liquid levels (single-phase pumps);

• without level switch for manual ON/OFF operation.

Pumps fitted with level switches can also be used formanual ON/OFF operation. In this case the level switchmust be secured in an upwards-pointing position.

Pump housingPump housing with an outstanding design for submers-ible wastewater pumps resulting in a high head.

The pump housing is made of a steel tube with a smoothsurface and a hydraulically correct shape ensuring freepassage of particles.

Base, pump inlet and pump housing are fastened to themotor by means of 4 springs enabling quick and easydismantling.

Discharge portAll AP50B pumps have a threaded horizontal dischargeport: R 2.

Shaft and bearingsThe shaft is made of stainless steel and rotates in main-tenance-free prelubricated ball bearings.

ImpellerThe stainless steel impeller is a Vortex impeller withL-shaped blades and a clearance of 50 mm (in the pumphousing). The blades are curved backwards to reduce anyharmful effect from solid particles and to reduce thepower consumption. The impeller has a protective cap toprevent the deposits of long-fibred material.

Shaft sealThe shaft seal is a combination of a mechanical shaftseal of the bellows type and a lip seal with 80 ml oilbetween them. The shaft seal has silicon carbide sealfaces.

Materials

TM0

1 41

88 4

99

8

TM0

0 5

477

400

0

Description Materials DIN

W.-Nr. AISI

Pump housing Stainless steel 1.4301 304

Impeller Stainless steel 1.4301 304

Washer Stainless steel 1.4301 304

Protective cap Novolen 2360 Kx

Motor unit completeParts in contact with liquid:Stainless steel

1.4305 316

Shaft with rotor Stainless steel/silumin 1.4401

Motor cable Neoprene

O-rings NBR rubber

Spring Stainless steel 1.4310

Pump inlet Stainless steel 1.4301 304

Base Polycarbonate

Oil Shell Ondina 15, non-toxic

29

Page 30: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

30

Technical data

AP50B

TM0

1 35

83 4

498

0 5 10 15 20 25 Q [m³/h]0

2

4

6

8

10

12

14

16

H[m]

0 1 2 3 4 5 6 7 8 Q [l/s]

0

20

40

60

80

100

120

140

160

p[kPa] AP50B

60 HzISO 9906 Annex A

AP50B.50.08.1

AP50B.50.08.3

A50B.50.11.1

AP50B.50.11.3

AP50B.50.15.3

0 5 10 15 20 25 Q [m³/h]0.0

0.4

0.8

1.2

1.6

2.0

P 1[kW]

0.0

0.5

1.0

1.5

2.0

2.5

P 1[hp]

AP50B.50.08.1

AP50B.50.08.3

AP50B.50.11.1

AP50B.50.11.3

AP50B.50.15.3

TM

01 3

583

3100

TM0

1 9

219

150

0

D

A

C

S

Pump type VoltageP1

[kW]P2

[kW]In

[A]Cos ϕ

Dimensions [mm]Weight

[kg]A C D S

AP50B.50.08.1.V 1 x 220-230 V 1.4 0.8 6.4 0.99 3.78 468 116 73 R2 10.1

AP50B.50.08.A1.V 1 x 220-230 V 1.4 0.8 6.4 0.99 3.78 468 116 73 R2 10.1

AP50B.50.08.3.V 3 x 200-220 V 1.31 0.8 4.12 0.92 5.32 468 116 73 R2 8.5

AP50B.50.11.1.V 1 x 220-230 V 1.8 1.1 8.42 0.97 3.56 468 116 73 R2 10.1

AP50B.50.11.A1.V 1 x 220-230 V 1.8 1.1 8.42 0.97 3.56 468 116 73 R2 10.1

AP50B.50.11.3.V 3 x 200-220 V 1.73 1.1 5.41 0.93 5.91 468 116 73 R2 9.8

AP50B.50.15.3.V 3 x 200-220 V 1.98 1.5 6.25 0.91 6.4 468 116 73 R2 10.0

Istart

In---------

Page 31: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Technical data

AP50B

AP50B installations

One-pump installation on auto-coupling

Two-pump installation on auto-coupling

TM0

1 35

93

449

8

••

• •

••

••

••

••

•••

••

••

••

••

••

••

••

• •

••

••

•••

••

• ••

••

• ••• •

••

•••

••

••

••

••

•••

••

• •

••

••

••

••

F

C

A

U

Z J

G

K L

N O

T

E

S

TM0

1 35

93

449

8

••

••

••

••

••

••

••

••

••

• •

••

••

••

••

••

••

D

I

M M

R PP

B

Pump typeDimensions [mm]

A B C D E F G I J K L M N O P R S T U Z

AP50B.50.08.1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261

AP50B.50.08.A1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261

AP50B.50.08.3.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261

AP50B.50.11.1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261

AP50B.50.11.A1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261

AP50B.50.11.3.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261

AP50B.50.15.3.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261

Pump typeDimensions [mm]

A B C D E F G I J K L M N O P R S T U Z

AP50B.50.08.1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261

AP50B.50.08.A1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261

AP50B.50.08.3.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261

AP50B.50.11.1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261

AP50B.50.11.A1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261

AP50B.50.11.3.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261

AP50B.50.15.3.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261

31

Page 32: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

32

Technical data

AP51

AP51 with single-channel impeller

The pumps are used for pumping wastewater, sludge-containing water, considerable quantities of surfacewater and ground water in places such as

• holiday homes,

• public buildings,

• factories,

• garages,

• underground car parks and

• car wash areas.

If permitted by local laws or regulations, the AP51 pumpscan be used for the pumping of sewage from single andmulti-family houses.

Pump and stator housingThe pump housing and the stator housing are made ofcast iron.

The stator housing is dry, i.e. not oil-filled.

DischargeAll AP51 pumps have a horizontal R 2½ discharge port forthreaded connection.

Shaft and bearingsThe shaft is made of stainless steel and rotates in main-tenance-free prelubricated ball bearings.

The lower bearing of AP51.65.22, AP51.65.23, AP51.65.34and AP51.65.35 comprises a double row of ball bearings.

ImpellerThe impeller is a closed single-channel cast iron impellerwith a clearance of 51 mm. Cast iron is chosen as it isresistant towards mechanically wearing particles.

The inlet side of the pump housing is fitted with areplaceable neck ring.

Shaft sealAP51.65.22 to Combination of mechanicalAP51.65.35 bellows seal and lip seal.

The primary shaft seal has siliconcarbide/silicon carbide seal faces.The secondary shaft seal is a lipseal. The chamber between theshaft seals is filled with 0.01 litre ofoil.

AP51.65.22 to Two mechanical bellows seals,AP51.65.35 with silicon carbide/silicon carbide

seal faces. The chamber betweenthe primary and the secondaryshaft seals is filled with 1.2 litre ofoil.

Motor cableStandard pumps 10 m: H07RNF.

Materials

Control boxFurther information about control box, float switch, andlevel controller, see page 40.

TM0

1 71

74 4

09

9

TM0

0 3

566

50

93

Description Materials DIN W.-Nr. AISI

Stator housing Cast iron GG 25 0.6025 ASTM 35B

Pump housing Cast iron GG 25 0.6025 ASTM 35B

Neck ring Bronze

Impeller Cast iron GG 25 0.6025 ASTM 35B

Shaft Stainless steel 1.4104 AISI 430F

Bearings Heavy-duty prelubricated ball bearings

Screws Stainless steel 1.4301 AISI 304

Oil Shell Ondina 15, non-toxic

Page 33: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Performance curves

AP51

TM0

0 6

774

479

9

0 10 20 30 40 50 60 70 Q [m³/h]

0

1

2

3

4

[kW]P1

0

2

4

P1[hp]

34.3 35.3

23.3

22.315.3

14.313.1

09.309.1

0 10 20 30 40 50 60 70 Q [m³/h]

0

4

8

12

16

20

24

28

[m]H

0 5 10 15 20 Q [l/s]

0

80

160

240

p [kPa] AP51.65.

60 HzISO 2548 Annex B

34.3

35.3

23.3

22.3

15.3

14.3

13.1

09.3

09.1

33

Page 34: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

34

Technical data

AP51

Elbow is an accessory.

TM0

1 25

64

209

8

S

E

C

D

B

A

Pump type VoltageP1

[kW]P2

[kW]n

[min-1]In

[A]Cos ϕ

Dimensions [mm]Weight

[kg]A B C D E S

AP51.65.09.1 1 x 230 V 1.2 0.9 3450 5.4 0.97 6.0 465 350 124 65 198 R 2½ 27 - 28

AP51.65.09.A1 1 x 230 V 1.2 0.9 3450 5.4 0.97 6.0 465 350 124 65 198 R 2½ 27 - 28

AP51.65.09.3 3 x 230 V 1.2 0.9 3450 4.0 0.79 6.0 465 350 124 65 198 R 2½ 26

AP51.65.09.3 3 x 380 V 1.2 0.9 3450 2.3 0.79 6.0 465 350 124 65 198 R 2½ 26

AP51.65.09.3 3 x 460 V 1.2 0.9 3450 1.9 0.79 6.0 465 350 124 65 198 R 2½ 26

AP51.65.13.1 1 x 230 V 1.8 1.3 3450 7.8 0.97 6.0 465 350 124 65 198 R 2½ 28 - 29

AP51.65.13.A1 1 x 230 V 1.8 1.3 3450 7.8 0.97 6.0 465 350 124 65 198 R 2½ 28 - 29

AP51.65.14.3 3 x 230 V 1.8 1.4 3450 5.6 0.83 6.0 465 350 124 65 198 R 2½ 27

AP51.65.14.3 3 x 380 V 1.8 1.4 3450 3.3 0.83 6.0 465 350 124 65 198 R 2½ 27

AP51.65.14.3 3 x 460 V 1.8 1.4 3450 2.7 0.83 6.0 465 350 124 65 198 R 2½ 27

AP51.65.15.3 3 x 230 V 1.8 1.4 3450 5.6 0.84 6.0 465 350 124 65 198 R 2½ 27

AP51.65.15.3 3 x 380 V 1.8 1.4 3450 3.3 0.84 6.0 465 350 124 65 198 R 2½ 27

AP51.65.15.3 3 x 460 V 1.8 1.4 3450 2.7 0.84 6.0 465 350 124 65 198 R 2½ 27

AP51.65.22.3 3 x 230 V 2.8 2.2 3450 8.4 0.88 6.0 518 368 101 50 185 R 2½ 45

AP51.65.22.3 3 x 380 V 2.8 2.2 3450 4.8 0.88 6.0 518 368 101 50 185 R 2½ 45

AP51.65.22.3 3 x 460 V 2.8 2.2 3450 4.0 0.88 6.0 518 368 101 50 185 R 2½ 45

AP51.65.23.3 3 x 230 V 2.8 2.3 3450 8.4 0.88 6.0 518 368 101 50 185 R 2½ 45

AP51.65.23.3 3 x 380 V 2.8 2.3 3450 4.8 0.88 6.0 518 368 101 50 185 R 2½ 45

AP51.65.23.3 3 x 460 V 2.8 2.3 3450 4.0 0.88 6.0 518 368 101 50 185 R 2½ 45

AP51.65.34.3 3 x 230 V 4.0 3.4 3450 12.5 0.84 6.0 518 368 101 50 185 R 2½ 45

AP51.65.34.3 3 x 380 V 4.0 3.4 3450 6.7 0.84 6.0 518 368 101 50 185 R 2½ 45

AP51.65.34.3 3 x 460 V 4.0 3.4 3450 6.0 0.84 6.0 518 368 101 50 185 R 2½ 45

AP51.65.35.3 3 x 230 V 4.0 3.5 3450 12.5 0.84 6.0 518 368 101 50 185 R 2½ 45

AP51.65.35.3 3 x 380 V 4.0 3.5 3450 6.7 0.84 6.0 518 368 101 50 185 R 2½ 45

AP51.65.35.3 3 x 380 V 4.0 3.5 3450 6.0 0.84 6.0 518 368 101 50 185 R 2½ 45

Istart

In---------

Page 35: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Technical data

AP51

AP51 installations

One-pump installation on auto-coupling

Two-pump installation on auto-coupling

TM0

1 25

65

209

8

‹‹

‹ ‹

‹ ‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹ ‹‹

‹‹

‹‹

‹‹‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹‹

‹‹

‹ ‹

‹‹

‹‹

‹ ‹

‹‹‹

‹ ‹‹

‹‹

‹ ‹‹

‹ ‹

K

G

H

L

N O

F

C

A

U

V

J

S

TM0

1 25

66

20

98

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹ ‹

‹ ‹‹

‹‹

‹‹

‹‹

‹ ‹

‹ ‹

RP P

MM

I

B

D

Pump type A B C D E F G H I J K L M N O P S T U V

AP51.65.09.1 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240

AP51.65.09.A1 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240

AP51.65.09.3 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240

AP51.65.13.1 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240

AP51.65.13.A1 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240

AP51.65.14.3 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240

AP51.65.15.3 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240

AP51.65.22.3 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240

AP51.65.23.3 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240

AP51.65.34.3 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240

AP51.65.35.3 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240

Pump type A B C D E F G H I J K L M N O P R S T U V

AP51.65.09.1 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240

AP51.65.09.A1 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240

AP51.65.09.3 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240

AP51.65.13.1 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240

AP51.65.13.A1 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240

AP51.65.14.3 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240

AP51.65.15.3 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240

AP51.65.22.3 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240

AP51.65.23.3 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240

AP51.65.34.3 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240

AP51.65.35.3 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240

35

Page 36: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

36

Technical data

AP51 Vortex

AP51 with Vortex impeller

The pumps are used for pumping wastewater, sludge-containing water, considerable quantities of surfacewater and ground water in places such as

• holiday homes,

• public buildings,

• factories,

• garages,

• underground car parks and

• car wash areas.

If permitted by local laws or regulations, the AP51 Vortexpumps can be used for the pumping of sewage fromsingle and multi-family houses.

Pump and stator housingThe pump housing and the stator housing are made ofcast iron.

The stator housing of AP51.65.14V and AP51.65.15V is dry,i.e. not oil-filled.

The stator housing of AP51.65.23V, AP51.65.34V,AP51.65.35V and AP51.65.36V is oil-filled.

All AP51 pumps are fitted with casted legs for free-standing installation.

DischargeAll AP51 pumps have a horizontal R 2½ discharge port forthreaded connection.

Shaft and bearingsThe shaft is made of chromium steel and rotates inmaintenance-free prelubricated ball bearings.

The lower bearing of AP51.65.23V, AP51.65.34V andAP51.65.36V comprises a double row of ball bearings.

All AP51 pumps are fitted with casted legs for free-standing installation.

ImpellerThe impeller is a vortex impeller in cast iron GG 25 witha free passage of 51 mm in the pump housing. Cast ironis chosen as it is resistant towards mechanically wearingparticles.

Shaft sealAP51.65.14, Combination of mechanical bellows AP51.65.15: seal and lip seal. The primary shaft

seal is made of silicon carbide/siliconcarbide. The secondary shaft seal is alip seal. The chamber between theshaft seals is oil-filled.

AP51.65.23, Two mechanical bellows seals and a AP51.65.34, lip seal. AP51.65.35, The primary and the secondary shaft AP51.65.36: seals are made of silicon carbide/

silicon carbide. The chamber betweenthe primary and the secondary shaftseals is oil-filled. Between the lowerball bearing and the stator housingthere is a lip seal.

Motor cableStandard pumps 10 m: H07RNF.

Materials

Control boxFurther information about control box, float switch, andlevel controller, see page 40.

TM0

1 71

74 4

09

9

TM0

1 26

17 2

09

8

Description Materials DIN W.-Nr. AISI

Stator housing Cast iron GG 25 0.6025 ASTM 35B

Pump housing Cast iron GG 25 0.6025 ASTM 35B

Neck ring Bronze

Impeller Cast iron GG 25 0.6025 ASTM 35B

Shaft Stainless steel 1.4104 AISI 430F

Bearings Heavy-duty prelubricated ball bearings

Screws Stainless steel 1.4301 AISI 304

Oil Shell Ondina 15, non-toxic

Page 37: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Performance curves

AP51 Vortex

TM0

0 6

776

479

9

0 5 10 15 20 25 30 35 40 45 Q [m³/h]0.00.51.01.52.02.53.03.54.0

[kW]P 1

0

1

2

3

4

5

P 1[hp]

AP51.65.36.3.VAP51.65.35.3.V AP51.65.34.3.V

AP51.65.23.3.V

AP51.65.15.3.VAP51.65.14.3.V AP51.65.14.1.V

0 5 10 15 20 25 30 35 40 45 Q [m³/h]0

2

4

6

8

10

12

14

16

18

20

22

24

[m]H

0 1 2 3 4 5 6 7 8 9 10 11 12 13 Q [l/s]

0

20

40

60

80

100

120

140

160

180

200

220

240

p [kPa]

AP5160 Hz

ISO 2548 Annex B

AP51.65.36.3.V

AP51.65.35.3.VAP51.65.34.3.V

AP51.65.23.3.VAP51.65.15.3.VAP51.65.14.3.VAP51.65.14.1.V

37

Page 38: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

38

Technical data

AP51 Vortex

Elbow is an accessory.

TM0

1 25

64

209

8

S

E

C

D

B

A

Pump type VoltageP1

[kW]P2

[kW]n

[min-1]In

[A]Cos ϕ

Dimensions [mm]Weight

[kg]A B C D E S

AP51.65.14.1.V 1 x 230 V 1.8 1.4 3450 8.0 0.99 6.0 465 350 124 65 198 R 2½ 27

AP51.65.14.A1.V 1 x 230 V 1.8 1.4 3450 8.0 0.99 6.0 465 350 124 65 198 R 2½ 27

AP51.65.14.3.V 3 x 230 V 1.8 1.4 3450 5.6 0.84 6.0 465 350 124 65 198 R 2½ 27

AP51.65.14.3.V 3 x 380 V 1.8 1.4 3450 3.3 0.84 6.0 465 350 124 65 198 R 2½ 27

AP51.65.14.3.V 3 x 460 V 1.8 1.4 3450 2.7 0.84 6.0 465 350 124 65 198 R 2½ 27

AP51.65.15.3.V 3 x 230 V 1.8 1.4 1750 5.4 0.70 6.0 518 368 101 50 187 R 2½ 27

AP51.65.15.3.V 3 x 380 V 1.8 1.4 1750 3.2 0.70 6.0 518 368 101 50 187 R 2½ 27

AP51.65.15.3.V 3 x 460 V 1.8 1.4 1750 2.6 0.70 6.0 518 368 101 50 187 R 2½ 27

AP51.65.23.3.V 3 x 230 V 2.8 2.3 3450 8.4 0.88 6.0 518 368 101 50 185 R 2½ 40

AP51.65.23.3.V 3 x 380 V 2.8 2.3 3450 4.8 0.88 6.0 518 368 101 50 185 R 2½ 40

AP51.65.23.3.V 3 x 460 V 2.8 2.3 3450 4.0 0.88 6.0 518 368 101 50 185 R 2½ 40

AP51.65.34.3.V 3 x 230 V 4.0 3.4 3450 12.5 0.84 6.0 555 368 101 50 185 R 2½ 45

AP51.65.34.3.V 3 x 380 V 4.0 3.4 3450 6.7 0.84 6.0 555 368 101 50 185 R 2½ 45

AP51.65.34.3.V 3 x 460 V 4.0 3.4 3450 6.0 0.84 6.0 555 368 101 50 185 R 2½ 45

AP51.65.35.3.V 3 x 230 V 4.0 3.5 3450 12.5 0.84 6.0 555 368 101 50 185 R 2½ 45

AP51.65.35.3.V 3 x 380 V 4.0 3.5 3450 6.7 0.84 6.0 555 368 101 50 185 R 2½ 45

AP51.65.35.3.V 3 x 460 V 4.0 3.5 3450 6.0 0.84 6.0 555 368 101 50 185 R 2½ 45

AP51.65.36.3.V 3 x 230 V 4.0 3.6 3450 12.5 0.84 6.0 555 368 101 50 185 R 2½ 45

AP51.65.36.3.V 3 x 380 V 4.0 3.6 3450 6.7 0.84 6.0 555 368 101 50 185 R 2½ 45

AP51.65.36.3.V 3 x 460 V 4.0 3.6 3450 6.0 0.84 6.0 555 368 101 50 185 R 2½ 45

Istart

In---------

Page 39: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Technical data

AP51 Vortex

AP51 installations

One-pump installation on auto-coupling

Two-pump installation on auto-coupling

TM0

1 25

65

209

8

‹‹

‹ ‹

‹ ‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹ ‹‹

‹‹

‹‹

‹‹‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹‹

‹‹

‹ ‹

‹‹

‹‹

‹ ‹

‹‹‹

‹ ‹‹

‹‹

‹ ‹‹

‹ ‹

K

G

H

L

N O

F

C

A

U

V

J

S

TM0

1 25

66

20

98

‹‹

‹‹

‹‹

‹‹

‹‹

‹‹

‹ ‹

‹ ‹‹

‹‹

‹‹

‹‹

‹ ‹

‹ ‹

RP P

MM

I

B

D

Pump type A B C D E F G H I J K L M N O P S T U V

AP51.65.14.1.V ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240

AP51.65.14.A1.V ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240

AP51.65.14.3.V ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240

AP51.65.15.3.V ø600 ø600 300 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240

AP51.65.23.3.V ø600 ø600 300 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240

AP51.65.34.3.V ø600 ø600 300 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240

AP51.65.35.3.V ø600 ø600 300 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240

AP51.65.36.3.V ø600 ø600 300 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240

Pump type A B C D E F G H I J K L M N O P R S T U V

AP51.65.14.1.V 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240

AP51.65.14.A1.V 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240

AP51.65.14.3.V 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240

AP51.65.15.3.V 600 975 300 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240

AP51.65.23.3.V 600 975 300 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240

AP51.65.34.3.V 600 975 300 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240

AP51.65.35.3.V 600 975 300 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240

AP51.65.36.3.V 600 975 300 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240

39

Page 40: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

40

Technical data Control box

Control box

Variants

The AP pump range comprises versions with or withoutcontrol box and float switch, versions designed forsingle-phase or three-phase power supply versions.

All types are designed for voltage tolerances of ±10%.

Pumps with control box and float switch

Some AP pumps can be supplied with a float switch forautomatic start/stop of the pump. The float switch cableshould be fastened to the retainer on the pump handle.

The difference in level between start and stop may beadjusted by adjusting the free length of cable betweenthe float switch and the retainer.Large difference in level: Long cable.Small difference in level: Short cable.The float switch is connected directly to the control boxthrough a 10 metres long cable.

The mains cable between the pump and the control boxis 10 metres long. The mains cable of the control box isan 0.8 metres long free cable end.

The control box includes a motor starter, and for single-phase pumps also an operating capacitor. The pumpsrequire no further motor protection.

An alarm signal can be given in case of a too high levelby means of a separate float switch connected to analarm. The high-level alarm switch and the alarm areavailable as accessories.

Further information about control boxes for a specificpump type, see "Product range", page 49.

Pumps with control box without float switch for manual on/off operation

The mains cable between the pump and the control- boxis 10 metres long. The mains cable of the control box isan 0.8 metres long free cable end.

The control box includes a motor starter and an oper-ating capacitor but no relays for float switch.

Pumps without control box.

Pumps without control box must be connected to aseparate motor starter. The motor starter is available asan accessory.

Single-phase pumps must also be connected to a capac-itor.

Level controller

A level controller and switches are available as optionalextras for the control, monitoring and protection ofthree-phase 60 Hz AP pumps. Level controller LC isdesigned for one-pump operation, and LCD for two-pump operation.

The level controller incorporates motor starter, contac-tors and light-emitting diodes (LC/LCD) for indication ofoperating condition.

Pump with control box and float switch.

Pumps with control box without float switch for manualon/off operation.

Two pumps with level controller LCD.

TM0

0 6

671

229

8TM

00

66

70 2

298

TM0

0 6

672

080

0

CU 212 2112

Page 41: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Technical data

AP80

AP80The pumps are used for pumping sewage, wastewater,considerable quantities of surface water and groundwater in places such as

• municipal pump pits,

• public buildings,

• block of flats,

• factories and

• underground car-parks.

Pump and stator housingThe pump housing and the stator housing are made ofcast iron.

The stator housing is dry, i.e. not oil-filled.

DischargeAll AP80 pumps have a horizontal discharge port with aDN 100 DIN flange.

Shaft and bearingsThe shaft is made of stainless steel and rotates in main-tenance-free prelubricated ball bearings.The lower bearing is a double-row ball bearing.

ImpellerThe impeller is a single-channel cast iron impeller with aclearance of 80 mm. Cast iron is chosen as it is resistanttowards mechanically wearing particles.

The inlet side of the pump housing is fitted with areplaceable neck ring.

Level controllerFurther information about level controller, see page 40.

Shaft sealTwo mechanical bellows seals with silicon carbide/silicon carbide seal faces.

The chamber between the primary and the secondaryshaft seal is filled with

• AP80.100.15-65 1.7 litres

• AP80.100.74-107 3.0 litres

InstallationAll AP80 pumps are fitted with motors for direct-on-linestarting. AP80 pumps with motors for star-delta startingare available on request.

Motor cableStandard pumps 10 m: H07RNF

Materials

Cooling jacketOn request all AP80 pumps can be supplied with a stain-less steel cooling jacket.

Liquid temperature with cooling jacket: 0°C to +40°C.For short periods, max. one hour: Up to +60°C. Forperiods longer than one hour, external cooling isrequired.

The cooling jacket is available for internal as well asexternal cooling of the motor in both dry and submergedinstallations.

Internal cooling (standard) is achieved by leading part ofthe pumped liquid around the stator housing and backto the pump housing via internal channels.

For external cooling the cooling jacket is fitted withsockets for pipe connections.

The cooling jacket is required for cooling of the motor indry installations, and in submerged installations if thepump is not completely submerged during continuousoperation.

TM0

0 5

488

089

5

Description Materials DIN W.-Nr. AISI/ASTM

Stator housing Cast iron GG 25 0.6025 ASTM 35B

Pump housing Cast iron GG 25 0.6025 ASTM 35B

Neck ring Bronze

Impeller Cast iron GG 25 0.6025 ASTM 35B

Shaft Stainless steel 1.4104 AISI 430F

Bearings Heavy-duty prelubricated ball bearings

Screws Stainless steel 1.4301 AISI 304

Cooling jacket Stainless steel 1.4301 AISI 304

Oil Shell Ondina 15, non-toxic

41

Page 42: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

42

Performance curves

AP80

TM0

1 36

37 4

498

0 20 40 60 80 100 120 140 160 180 200 Q [m³/h]

0

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

H[m]

0 5 10 15 20 25 30 35 40 45 50 55 60 Q [l/s]

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

p[kPa] AP80.100

60 HzISO 2548 Annex B

AP80.100.15

AP80.100.21

AP80.100.27

AP80.100.35

AP80.100.47

AP80.100.65

AP80.100.74

AP80.100.87

AP80.100.107

0 20 40 60 80 100 120 140 160 180 200 Q [m³/h]

0

2

4

6

8

10

12

P1[kW]

0

2

4

6

8

10

12

14

16

P1[hp]

107

87

74

65

47

35

2721

15

Page 43: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Technical data

AP80

DN 100/DN 100

DN 150/DN 100

TM0

1 42

54 5

09

8TM

01

470

1 0

799

DN100

DN100

ø15

X

W

200

1 1/2"

8760

415

240

240

2020

270

200

G

HV

U

Y

AP80.100.15-74

W

X

110100

2"

280

V

U

27545

0

2020

300

400

340

Y

H

G

ø15

DN100

DN150

AP80.100.15-74

TM0

1 42

58 5

09

8TM

01

470

2 0

799

DN100

DN100

ø15

X

W

200

1 1/2"

8760

415

240

240

2020

270

200

V

Y

H

GU

AP80.100.87-107

W

X

110100

2"

280

27545

0

2020

300

400

340

ø15

DN100

DN150

V

U

H

G

Y

AP80.100.87-107

43

Page 44: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

44

Technical data

AP80

Submerged free-standing installation

TM0

1 42

55 5

09

8

AP80.100.15-74

J

G

H

ø395 125

DN100

DN100

120

A

B

D

C

F

E

TM0

1 42

59 5

09

8

ø395 125

DN100

DN100

120

A

B

C

F

E

D

J

G

H

AP80.100.87-107

Page 45: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Technical data

AP80

Dimensions for installation on auto-coupling DN 100

Dimensions for installation on auto-coupling DN 150

Dimensions for submerged free-standing installation

Pump typeDimensions [mm]

V W U G H X Y

AP80.100.15 147 347 852 307 147 589 767

AP80.100.21 147 347 852 307 147 589 767

AP80.100.27 147 347 852 307 147 589 767

AP80.100.35 147 347 852 307 147 589 767

AP80.100.47 147 347 922 307 147 589 767

AP80.100.65 122 377 927 363 165 643 871

AP80.100.74 122 377 927 363 165 643 871

AP80.100.87 122 377 1023 363 165 643 871

AP80.100.107 122 377 1083 363 165 643 871

Pump typeDimensions [mm]

V W U G H X Y

AP80.100.15 156 425 961 307 147 714 1027

AP80.100.21 156 425 961 307 147 714 1027

AP80.100.27 156 425 961 307 147 714 1027

AP80.100.35 156 425 961 307 147 714 1027

AP80.100.47 156 425 961 307 147 714 1027

AP80.100.65 156 425 961 363 165 714 1027

AP80.100.74 156 425 961 363 165 714 1027

AP80.100.87 156 425 1207 363 165 714 1027

AP80.100.107 156 425 1207 363 165 714 1027

Pump typeDimensions [mm]

A B D E F G H

AP80.100.15 705 830 218 355 200 307 147

AP80.100.21 705 830 218 355 200 307 147

AP80.100.27 705 830 218 355 200 307 147

AP80.100.35 705 830 218 355 200 307 147

AP80.100.47 775 900 218 355 200 307 147

AP80.100.65 805 930 244 459 280 363 165

AP80.100.74 805 930 244 459 280 363 165

AP80.100.87 901 1026 244 459 280 363 165

AP80.100.107 961 1086 244 459 280 363 165

45

Page 46: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

46

Technical data

AP80

Electrical data and weights

Pump type VoltageP1

[kW]P2

[kW]n

[min-1]In

[A]Cos ϕ Weights

[kg]

AP80.100.15 3 x 230 V 1.7 1.5 1750 6.2 0.87 1.3 95

AP80.100.15 3 x 380 V 1.7 1.5 1750 3.8 0.87 1.3 95

AP80.100.15 3 x 440 V 1.7 1.5 1750 3.2 0.87 1.3 95

AP80.100.15 3 x 460 V 1.7 1.5 1750 3.1 0.87 1.3 95

AP80.100.21 3 x 230 V 2.6 2.1 1750 7.8 0.87 4.0 95

AP80.100.21 3 x 380 V 2.6 2.1 1750 4.7 0.87 4.0 95

AP80.100.21 3 x 440 V 2.6 2.1 1750 4.1 0.87 4.0 95

AP80.100.21 3 x 460 V 2.6 2.1 1750 3.9 0.87 4.0 95

AP80.100.27 3 x 230 V 3.2 2.7 1750 9.2 0.86 6.0 99

AP80.100.27 3 x 380 V 3.2 2.7 1750 5.6 0.86 6.0 99

AP80.100.27 3 x 440 V 3.2 2.7 1750 4.8 0.86 6.0 99

AP80.100.27 3 x 460 V 3.2 2.7 1750 4.6 0.86 6.0 99

AP80.100.35 3 x 230 V 4.1 3.5 1750 12.0 0.87 5.0 100

AP80.100.35 3 x 380 V 4.1 3.5 1750 7.3 0.87 5.0 100

AP80.100.35 3 x 440 V 4.1 3.5 1750 6.3 0.87 5.0 100

AP80.100.35 3 x 460 V 4.1 3.5 1750 6.0 0.87 5.0 100

AP80.100.47 3 x 230 V 5.5 4.7 1750 16.0 0.87 5.5 124

AP80.100.47 3 x 380 V 5.5 4.7 1750 9.7 0.87 5.5 124

AP80.100.47 3 x 440 V 5.5 4.7 1750 8.4 0.87 5.5 124

AP80.100.47 3 x 460 V 5.5 4.7 1750 8.0 0.87 5.5 124

AP80.100.65 3 x 230 V 7.5 6.5 1750 22.0 0.87 5.0 126

AP80.100.65 3 x 380 V 7.5 6.5 1750 13.3 0.87 5.0 126

AP80.100.65 3 x 440 V 7.5 6.5 1750 11.5 0.87 5.0 126

AP80.100.65 3 x 460 V 7.5 6.5 1750 11.0 0.87 5.0 126

AP80.100.74 3 x 230 V 8.5 7.4 1750 24.6 0.87 5.0 126

AP80.100.74 3 x 380 V 8.5 7.4 1750 14.9 0.87 5.0 126

AP80.100.74 3 x 440 V 8.5 7.4 1750 12.9 0.87 5.0 126

AP80.100.74 3 x 460 V 8.5 7.4 1750 12.3 0.87 5.0 126

AP80.100.87 3 x 230 V 10.7 8.7 1750 29.0 0.88 5.0 196

AP80.100.87 3 x 380 V 10.7 8.7 1750 17.6 0.88 5.0 196

AP80.100.87 3 x 440 V 10.7 8.7 1750 16.0 0.88 5.0 196

AP80.100.87 3 x 460 V 10.7 8.7 1750 14.5 0.88 5.0 196

AP80.100.107 3 x 230 V 12.3 10.7 1750 37.0 0.82 7.0 223

AP80.100.107 3 x 380 V 12.3 10.7 1750 22.4 0.82 7.0 223

AP80.100.107 3 x 440 V 12.3 10.7 1750 19.3 0.82 7.0 223

AP80.100.107 3 x 460 V 12.3 10.7 1750 18.5 0.82 7.0 223

Istart

In---------

Page 47: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Technical data

APG

APG pumps

APG pumps are specifically designed for the pumping ofsewage from small villages and farms, and in areas ofdifficult topography, e.g. rocky terrain with large differ-ences in level.

A cutter system at the impeller inlet cuts destructiblesolids into small pieces so that the sewage can be ledaway through pipes of a relatively small diameter.

Due to the pressurized pumping system, the APG pumpsare especially efficient in areas where traditional gravitypumping systems cannot be used.

ApprovalsPA-I no. 3986.

Pump and stator housingThe pump housing and the stator housing are made ofcast iron.

The stator housing is dry, i.e. not oil-filled.

DischargeAll APG pumps have an externally threaded dischargeport: R 2.

Impeller and cutter systemThe impeller is a semi-open multivane cast iron im-peller.

The cutter system consists of a stationary ring with fourcutting edges and a rotating cutting head at the end ofthe pump shaft. The cutter system is made ofspecial,hardened high-alloy steel.

An adjustable cast iron wear plate is fitted at the inletside of the impeller.

Shaft and bearingsThe shaft is made of stainless steel and rotates in main-tenance-free prelubricated ball bearings.

The lower bearing comprises a double row of ball bear-ings.

Shaft seals

APG.50.11 - 12:

Combination of mechanical shaft seal and lip seal.

The primary shaft seal has silicon carbide/silicon carbideseal faces. The secondary shaft seal is a lip seal. Thechamber between the shaft seals is filled with 0.7 litre ofoil.

APG.50.18 - 33:

Two mechanical bellows seals.

The primary and the secondary shaft seals have siliconcarbide/silicon carbide seal faces. The chamber betweenthe primary and the secondary shaft seals is filled with1.2 litres of oil.

Motor cableStandard pumps 10 m: H07RNF.

Materials

TM0

1 71

82 4

09

9

TM0

0 3

576

519

3

Description Material DIN W.-Nr.AISI/ASTM

Stator housing Cast iron GG 25 0.6025 ASTM 35.B

Pump housing Cast iron GG 25 0.6025 ASTM 35.B

Wear plate Cast iron GG 25 0.6025 ASTM 35.B

Impeller Cast iron GG 25 0.6025 ASTM 35.B

Shaft Stainless steel 1.4104 AISI 430 F

Cutter system Hardened steel

Bearings Heavy-duty prelubricated ball bearings

Screws Stainless steel 1.4301 AISI 304

Oil Shell Ondina 15, non-toxic

47

Page 48: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

48

Performance curves

APG

TM0

0 7

216

159

9

0 2 4 6 8 10 12 14 16 18 Q [m³/h]

0

5

10

15

20

25

30

35

40

45

50

H[m]

0 1 2 3 4 5 Q [l/s]

0

100

200

300

400

500

p[kPa] APG

60 HzISO 2548 Annex B

APG.50.33.1APG.50.29.3APG.50.30.1

APG.50.18.1APG.50.19.3APG.50.11.3APG.50.12.1

0 2 4 6 8 10 12 14 16 18 Q [m³/h]

0

1

2

3

4

P1[kW]

0

2

4

6

P1[hp]

APG.50.33.1

APG.50.29.3

APG.50.30.1

APG.50.19.3 APG.50.18.1

APG.50.11.3

APG.50.12.1

Page 49: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Technical data

APG

Elbow and ring stand are accessories.

TM0

1 26

03

209

8

B

D C

E

A

S

Pump type VoltageP1

[kW]P2

[kW]n

[min]In

[A]Cos ϕ

Dimensions [mm]Weight *

[kg]A B C D E S

APG.50.11.3 3 x 230 V 1.5 1.1 3450 6.2 0.63 6.0 450 304 133 90 207 R 2 26

APG.50.11.3 3 x 380 V 1.5 1.1 3450 3.6 0.63 6.0 450 304 133 90 207 R 2 26

APG.50.11.3 3 x 460 V 1.5 1.1 3450 3.0 0.63 6.0 450 304 133 90 207 R 2 26

APG.50.12.1 1 x 230 V 1.5 1.2 3450 8.0 0.82 6.0 450 304 133 90 207 R 2 28 - 30

APG.50.12.A1 1 x 230 V 1.5 1.2 3450 8.0 0.82 6.0 450 304 133 90 207 R 2 28 - 30

APG.50.18.1 1 x 230 V 2.6 1.8 3450 12.0 0.94 6.0 620 408 191 150 265 R 2 36 - 37

APG.50.18.A1 1 x 230 V 2.6 1.8 3450 12.0 0.94 6.0 620 408 191 150 265 R 2 36 - 37

APG.50.19.3 3 x 230 V 2.6 1.9 3450 8.4 0.80 6.0 620 408 191 150 265 R 2 33

APG.50.19.3 3 x 380 V 2.6 1.9 3450 4.9 0.80 6.0 620 408 191 150 265 R 2 33

APG.50.19.3 3 x 460 V 2.6 1.9 3450 4.2 0.80 6.0 620 408 191 150 265 R 2 33

APG.50.29.3 3 x 230 V 3.7 2.9 3450 11.4 0.86 6.0 751 408 191 150 265 R 2 44

APG.50.29.3 3 x 380 V 3.7 2.9 3450 6.4 0.86 6.0 751 408 191 150 265 R 2 44

APG.50.29.3 3 x 460 V 3.7 2.9 3450 5.2 0.86 6.0 751 408 191 150 265 R 2 44

APG.50.30.1 1 x 230 V 3.7 3.0 3450 20.0 0.85 6.0 751 408 191 150 265 R 2 48 - 50

APG.50.30.A1 1 x 230 V 3.7 3.0 3450 20.0 0.85 6.0 751 408 191 150 265 R 2 48 - 50

APG.50.33.1 1 x 230 V 3.7 3.3 3450 20.0 0.80 6.0 751 408 191 150 265 R 2 48 - 50

APG.50.33.A1 1 x 230 V 3.7 3.3 3450 20.0 0.80 6.0 751 408 191 150 265 R 2 48 - 50

* Pump inclusive of cable.

Istart

In---------

49

Page 50: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

50

Technical data

APG

APG installations

One-pump installation on auto-coupling

Two-pump installation on auto-coupling

TM0

1 26

06

20

98

••

••

• •

••

••

••

••

••

••

••

••

••

••

••

••

V

U

F

A

G

K

N

L

O

J

C

T

E

S

TM0

1 26

07

209

8

‹‹

‹‹

‹ ‹

‹‹

‹‹‹

‹‹

B

D

I

MM

P R P

Pump type A B C D E F G I J K L M N O P S T U V

APG.50.11.3 ø600 ø600 393 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300

APG.50.12.1 ø600 ø600 393 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300

APG.50.12.A1 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300

APG.50.18.1 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300

APG.50.18.A1 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300

APG.50.19.3 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300

APG.50.29.3 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300

APG.50.30.1 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300

APG.50.30.A1 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300

APG.50.33.1 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300

APG.50.33.A1 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300

Pump type A B C D E F G I J K L M N O P R S T U V

APG.50.11.3 455 600 393 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300

APG.50.12.1 455 600 393 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300

APG.50.12.A1 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300

APG.50.18.1 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300

APG.50.18.A1 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300

APG.50.19.3 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300

APG.50.29.3 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300

APG.50.30.1 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300

APG.50.30.A1 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300

APG.50.33.1 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300

APG.50.33.A1 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300

Page 51: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Accessories LC

107, LCD 107

LC 107, LCD 107The LC 107 and LCD 107 pump controllers are designedfor level control, monitoring and protection of GrundfosKP, AP and APG pumping systems up to 23 A/11 kW (P1) per pump starting direct-on-line.

• LC 107 is a one-pump controller.

• LCD 107 is a two-pump controller.

LC 107 and LCD 107 are supplied as a complete controllerincorporating motor protection relay, bell-shaped levelpickups, pneumatic tubes and control unit.

Control is based on pneumatic signals which the LC 107 and LCD 107 receive via pneumatic tubes from 2 or3 level pickups positioned in a pump pit.

The LC 107 and LCD 107 enable:

• control of 1 or 2 pumps based on signals from bell-shaped level pickups,

• automatic pump changeover (even distribution of operating hours on both pumps),

• automatic test run during long periods of inactivity to prevent the shaft from seizing up,

• protection against water hammer as quick restart/simultaneous start is blocked and delayed,

• battery back-up in case of mains supply failure(accessory!),

• starting delay within the range from 0 to 255 sec. (random) after returning from battery operation to mains operation (resulting in an even mains load when several pumping stations are started up at the same time),

• selection of automatic alarm resetting,

• selection of automatic restarting,

• setting of stop delays matching the actual operating conditions,

• indication of liquid level,

• alarm indication of:– too high liquid level, which triggers a high-level

alarm,– overload (via motor protection relay),– overtemperature (via PTC resistance/thermal

switch in motor),– wrong phase sequence,– mains supply failure,– failing level pickup.

As standard, the LC 107 and LCD 107 have two alarmsignal outputs:

• common alarm,

• high-level alarm.

TM0

1 49

21 1

199

TM0

1 49

22 1

199

Settablestop delay Stop of pump

Start of pump

High-level alarm

Pump

LC 107

LCD 107

Pump 2

Pump 1

Settablestop delay

High-level alarmStart of second pump

Start of first pumpCommon stop

51

Page 52: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

52

Accessories LLC

C 107, LCD 107 108, LCD 108

Technical dataVoltage tolerances

–15%/+10% of nominal voltage.

Mains frequency

50/60 Hz.

Ambient temperature

• During operation: –30°C to +50°C(must not be exposed to direct sunlight).

• In stock: –30°C to +60°C.

Enclosure class

IP 55.

Pneumatic tubes

• Maximum 20 m per tube(standard: pneumatic tube of 10 metres).

• Diameter: 10 mm.

• Material: PA 11.

Outputs for alarm devices

Max. 400 VAC / max. 2 A / min. 10 mA / AC 1.

LC 108, LCD 108The LC 108 pump controller is a one-pump controllerdesigned for level control, monitoring and protection ofpumps in wastewater, water supply and drainagesystems.

Up to 23 A/11 kW (P1) starting direct-on-line (DOL).Up to 72 A/30 kW (P1) starting star-delta (Y/D).

The LC 108 is supplied as a complete controller incorpo-rating motor protection relay and control unit.

The LC 108 enables:

• control of one pump based on signals from float switches, electrodes or flow switches,

• automatic test run (every 24 hours) during long peri-ods of inactivity to prevent the shaft from seizing up,

• protection against water hammer as quick restart is blocked and delayed (5 seconds),

• selection of automatic alarm resetting,

• selection of automatic restarting (after overtempera-ture),

• setting of stop delays matching the actual operating conditions,

• indication of liquid level,

• alarm indication of:

• - wrong phase sequence,

- inadmissibly high liquid level,

- overload (via motor protection relay),- overtemperature (via PTC resistance or thermal

switch in motor),- defective float switch, electrode or flow switch,

- dry running,

- mains supply failure (by installing a battery back-up which is available as an accessory).

As standard, the LC 108 controller incorporates a buzzerfor indication of alarm.

Furthermore, the controller has one alarm output forcommon alarm.

Applications

The LC 108 can be connected and set to operation/control in 7 different ways:

• systems with 2 float switches,

• systems with 3 float switches,

• systems with 4 float switches,

• systems with 2 electrodes,

• systems with 3 electrodes,

• systems for filling applications,

• systems for drainage applications.

Technical dataVoltage tolerances

–15%/+10% of nominal voltage.

Mains frequency

50/60 Hz.

Ambient temperature

• During operation: –30°C to +50°C(must not be exposed to direct sunlight).

• In stock: –30°C to +60°C.

Enclosure class

IP 55.

Outputs for alarm devices

Max. 400 VAC / max. 2 A / min. 10 mA / AC 1.

Supply system earthing

For TN systems and TT systems.

Rated insulation voltage, Ui

4 kV.

Rated impulse withstand voltage, Uimp

4 kV.

EMC (electromagnetic compatibility)

According to EN 50 081-1 and EN 50 082-2.

Page 53: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Accessories LC

108, LCD 108

Level switchesThe AP pumps in combination with LC 108 or LCD 108 areavailable with level switches for automatic level control.Level switches supplied by Grundfos are of the non-mercury type.

LC 108 can be fitted with up to three level switches:

1. Min.: Stops the pump.2. Max.: Starts the pump.3. Alarm: Alarm (optional):

high water level or pump fault.

LCD 108 can be fitted with up to four level switches:

1. Min.: Stops both pumps.2. Max. 1: Starts one pump.3. Max. 2: Starts the other pump.4. Alarm: Alarm (optional):

high water level or pump fault.

The level switches are to be installed in the pit floatingon the pumped liquid.

The position of the level switches decides when LC 108 orLCD 108 starts and stops the AP pumps:

• When the level switch is pointing upwards, the level switch contact will be closed and the pump will start.

• When the level switch is pointing downwards, the the level switch contact will be opened and the pump will stop.

Dimensions

TM0

0 6

678

46

95

ON

OFFTM

01

90

07

030

3

TypeDimensions [mm]

H L B

LC 107, direct-on-lineLCD 107, direct-on-line

350 250 136

LC 108, direct-on-lineLCD 108, direct-on-line

350 250 136

LC 108, Star/delta 590 380 200

LCD 108, Star/delta 635 500 220

B

L

H

53

Page 54: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

54

Accessories

AP, KP

Accessories for AP, KP stainless steel pumps

Pos.Accessories Pump type

ProductnumberDescription KP

AP12.40

AP12.50

AP35

AP35B

AP50

AP50B

1 Bushing for pipe connection (PVC)Rp 1½/2 ! ! 96 02 38 31

Rp 2/2½ ! ! 96 02 38 32

2 Hose nipple (PVC)

Rp 1½/1½ ! ! 96 00 39 97

Rp 1½/2 ! ! 96 02 38 34

Rp 2/2 ! ! 96 02 38 35

Rp 2/2½ ! ! 96 02 38 36

3 10 m rubber hose incl. clamps (PVC)

1½" ! ! 96 02 38 37

2" ! ! ! ! 96 02 38 38

2½" ! ! 96 02 38 39

4 Connecting piece for rubber hoses (PVC)

RP 1½ ! ! 96 02 38 40

RP 2 ! ! ! ! 96 02 38 41

RP 2½ ! ! 96 02 38 42

5 Non-return valve (PVC)Ball type

Rp 1½ ! ! 96 02 38 43

Rp 2 ! ! ! ! 96 02 38 44

Rp 2½ # ! ! 96 00 20 03

6 Isolating valve (PVC)

Rp 1½ ! ! 96 02 38 46

Rp 2 ! ! ! ! 96 02 38 47

Rp 2½ ! ! 96 02 38 48

7 Hexagon nipple (PVC)

Rp 1½ ! ! 96 02 38 49

Rp 2 ! ! ! ! 96 02 38 50

Rp 2½ ! ! 96 02 38 51

8 Union (PVC)

Rp 1½ ! ! 96 02 38 52

Rp 2 ! ! ! ! 96 02 38 53

Rp 2½ ! ! 96 02 38 54

9 90° pipe bend (PVC)

Rp 1½ ! ! 96 02 38 55

Rp 2 ! ! ! ! 96 02 38 56

Rp 2½ ! ! 96 02 38 57

10Non-return valvefor location in the pump discharge (stainless steel)

Rp 1¼ ! 00 01 52 11

Rp 1½ ! ! 96 00 38 55

Auto-coupling Rp 2/Rp 2 ! ! 96 42 95 19

Hose couplingsScrewed couplings (polyamide)

G 1¼ x ø25 ! 00 ID 35 88

G 1¼ x ø32 ! 00 ID 35 89

G 1¼ x ø40 ! 00 ID 35 90

# Cast iron

TM0

0 5

924

189

5

TM0

0 5

925

18

95

TM0

1 87

08

070

0

3

2

3

4

7

9

8

1

5

7

6

7

1010

10

Page 55: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Accessories

AP

Accessories for cast iron AP pumpsAccessories Pump type

ProductnumberPos. Description AP30 AP51

AP51Vortex

AP80 APG

10 90° elbowR/Rp 2 ! 96 00 19 80

R/Rp 2½ ! ! 96 00 19 81

11 Coupling halfStorz coupling

Rp 2 2" hose ! ! 96 00 19 82

Rp 2½ - 2" hose ! ! 96 00 19 83

12Ring standEx. 90° elbow

DN 100/DN 100 - 4" hose ! 96 00 34 24

DN 150/DN 100 - 4" hose ! 96 00 38 35

R 2 (1.7/1.8/1.9/3.1 kW) ! 96 00 01 86

13 10 m rubber hoseincl. couplings

2" ! ! 96 00 19 87

14 90° elbowRp/Rp 2 ! ! 96 00 19 90

Rp/Rp 2½ ! ! 96 00 19 91

1590° elbow withflanges

DN 65, PN 10 96 00 36 16

DN 100, PN 10 ! 96 00 36 18

16 Hexagon nippleR/R 2 ! ! 96 00 19 93

R/R 2½ ! ! 96 00 19 94

17 Threaded flange

Rp 2 ! 96 00 44 51

Rp 2½ ! ! 96 00 19 96

Rp 4 ! 96 00 33 36

18 Bolts, nuts and gaskets

4 of each M16 x 65 mm DN 65

! ! 96 00 19 98

8 of each M16 x 65 mm DN 100

! 96 00 38 23

19 Gasket

DN 50 ! 96 00 54 68

DN 65 ! ! 96 00 20 00

DN 100 ! 96 00 33 31

20Discharge pipe with2 flanges , bolts, nuts and gasketsLength = 1 m

DN 65, PN 10 ! ! 96 00 36 10

DN 100, PN 10 ! 96 00 36 12

20aDischarge pipeextension (1 m)

DN 65, PN 10 ! ! 96 00 36 13

DN 100, PN 10 ! 96 00 36 15

21 Non-return valveCast iron ball-typevalve

Rp/Rp 2 ! ! 96 00 20 02

Rp/Rp 2½ ! ! 96 00 20 03

22 Isolating valveBrass

Rp/Rp 2 ! ! 96 00 20 05

Rp/Rp 2½ ! ! 96 00 20 06

23Non-return valveCast iron ball-type valve

DN 65 ! ! 96 00 20 08

DN 100 ! 96 00 20 85

24Isolating valveCast iron

DN 65 ! ! 96 00 20 10

DN 100 ! 96 00 20 12

25 Auto-couplingsystem complete

Rp 2/Rp 2 ! 96 00 01 78

Rp 2/Rp 2 with slant claw ! 96 00 33 41

Rp 2/Rp 2, hook-up ! ! 96 00 44 42

DN 65/Rp 2½ ! ! 96 00 01 80

DN 100/DN 100 ! 96 00 66 58

DN 150/DN 100 ! 96 00 66 59

26 Chain with shackle - galvanized(AP100 up to and including 17 kW)

10 m ! ! ! ! ! 96 00 20 13

6 m ! ! 96 00 36 33

3 m ! ! 96 00 36 34

27Collecting steel pipes for two pumps and 90° out-let, centre discharge flanges are welded. Pipes are painted.

3 x DN 65 ! ! 96 00 36 19

DN 65/65/80 ! ! 96 00 36 20

3 x DN 100 ! 96 00 36 23

28 BasestandDry pit standfor vertical installation incl. 90° suction elbow

DN 100/DN 100 ! 96 00 36 25

29 Cable protection 5 m x 1" ! ! ! ! 96 00 20 84

55

Page 56: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

56

Accessories

AP

30

Float switch without mercury 1 switch with 10 m cable ! ! ! ! ! 96 00 33 32

Float switch with 20 m cable ! ! ! ! ! 96 00 36 95

Bracket for level switch ! ! ! ! 96 00 33 38

Standard float switch without mercuryWith 10 m cable, counter weightand bracket

1 pump without alarm(2 switches)

! ! ! ! ! 62 50 00 13

1 pump with alarm(3 switches)

! ! ! ! ! 62 50 00 14

2 pumps without alarm(3 switches)

! ! ! ! ! 62 50 00 14

2 pumps with alarm(4 switches)

! ! ! ! ! 62 50 00 15

31 Signal lamp 1 x 230 V Outdoor mounting ! ! ! ! ! 62 50 00 20

32 Acoustic signal (horn) 1 x 230VOutdoor mounting ! ! ! ! ! 62 50 00 21

Indoor mounting ! ! ! ! ! 62 50 00 22

33Discharge pipe with 90° bend and two flanges.For 1 pump.

DN 65, L = 1300 mm ! ! 96 00 38 42

DN 80, L = 1300 mm 96 00 38 43

DN 100, L = 1300 mm ! 96 00 38 44

DN 150, L = 1300 mm ! 96 00 38 45

DN 150, L = 1600 mm ! 96 00 39 79

34Collecting steel pipes for two pumps.Sideways discharge

DN 65, L = 1920 mm ! ! 96 00 38 46

DN 80, L = 1920 mm 96 00 38 47

DN 100, L = 1920 mm ! 96 00 38 48

DN 150, L = 1920 mm ! 96 00 38 49

DN 150, L = 2220 mm ! 96 00 39 80

Accessories Pump typeProductnumberPos. Description AP30 AP51

AP51Vortex

AP80 APG

Page 57: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Accessories

AP

Level controllers and accessories

Accessories for controllers

Description

Op

erat

ing

cu

rren

tp

er p

um

p [

A]

Mai

ns

swit

ch

req

uir

ed [

A]

Gru

nd

fos

Pro

du

ct n

o.*

Gru

nd

fos

pro

du

ct n

o.in

clu

din

g h

ou

r co

un

ter*

Gru

nd

fos

pro

du

ct n

o.

incl

ud

ing

sta

rt c

ou

nte

r*

Gru

nd

fos

pro

du

ct n

o.

incl

ud

ing

co

mb

ined

ho

ur

and

sta

rt c

ou

nte

r*

TM0

1 88

74 0

800

LC 107 level controller for 1 pump1 x 230 V, direct-on-line starting

1 - 2.9 25 96 00 24 641.6 - 5.0 25 96 00 24 653.7 - 12.0 25 96 00 24 66

LC 107 level controller for 1 pump3 x 400 V, direct-on-line starting

1 - 2.9 25 96 00 24 671.6 - 5.0 25 96 00 24 683.7 - 12.0 25 96 00 24 6912.0 - 23.0 40 96 00 24 70

TM0

1 88

75 0

800

LCD 107 level controller for 2 pumps1 x 230 V, direct-on-line starting

1 - 2.9 25 96 00 24 711.6 - 5.0 25 96 00 24 723.7 - 12.0 25 96 00 24 73

LCD 107 level controller for 2 pumps3 x 400 V, direct-on-line starting

1 - 2.9 25 96 00 24 741.6 - 5.0 25 96 00 24 753.7 - 12.0 25 96 00 24 7612.0 - 23.0 40 96 00 24 77

TM0

1 88

73 0

800

LC 108 level controller for 1 pump1 x 230 V, direct-on-line starting

1 - 2.9 25 96 43 39 56 96 43 39 57 96 43 39 58 96 43 39 591.6 - 5.0 25 96 43 39 61 96 43 39 60 96 43 39 62 96 43 39 633.7 - 12.0 25 96 43 39 64 96 43 39 65 96 43 39 66 96 43 39 6712.0 - 23.0 40 96 43 39 71 96 43 39 72 96 43 39 73 96 43 39 74

LC 108 level controller for 1 pump3 x 230 V, direct-on-line starting

1 - 2.9 25 96 43 39 75 96 43 39 76 96 43 39 77 96 43 39 781.6 - 5.0 25 96 43 39 79 96 43 39 80 96 43 39 81 96 43 39 823.7 - 12.0 25 96 43 39 83 96 43 39 84 96 43 39 85 96 43 39 8612.0 - 23.0 40 96 43 39 87 96 43 39 88 96 43 39 89 96 43 39 90

LC 108 level controller for 1 pump3 x 400 V, direct-on-line starting

1 - 2.9 25 96 43 39 91 96 43 39 92 96 43 39 93 96 43 39 941.6 - 5.0 25 96 43 39 95 96 43 39 96 96 43 39 97 96 43 39 983.7 - 12.0 25 96 43 39 99 96 43 40 00 96 43 40 01 96 43 40 0212.0 - 23.0 40 96 43 40 03 96 43 40 04 96 43 40 05 96 43 40 06

LC 108 level controller for 1 pump3 x 400 V, star-delta starting

6.4 - 20.0 25 96 43 79 2820.8 - 30.0 40 96 43 79 5020.8 - 59.0 80 96 43 79 7024.2 - 72.0 96 43 79 90

TM0

1 88

76 0

800

LCD 108 level controller for2 pumps3 x 230 V, direct-on-line starting

1 - 2.9 25 96 43 40 23 96 43 40 24 96 43 40 25 96 43 40 261.6 - 5.0 25 96 43 40 27 96 43 40 28 96 43 40 29 96 43 40 303.7 - 12.0 25 96 43 40 31 96 43 40 32 96 43 40 33 96 43 40 3412.0 - 23.0 40 96 43 40 35 96 43 40 36 96 43 40 37 96 43 40 38

LCD 108 level controller for2 pumps3 x 400 V, direct-on-line starting

1 - 2.9 25 96 43 40 39 96 43 40 40 96 43 40 41 96 43 40 421.6 - 5.0 25 96 43 40 43 96 43 40 44 96 43 40 45 96 43 40 463.7 - 12.0 40 96 43 40 47 96 43 40 48 96 43 40 49 96 43 40 5012.0 - 23.0 60 96 43 40 51 96 43 40 52 96 43 40 53 96 43 40 54

LCD 108 level controller for2 pumps3 x 400 V, star-delta starting

6.4 - 20.0 25 96 43 80 3220.8 - 30.0 40 96 43 80 5220.8 - 59.0 80 96 43 80 7224.2 - 72.0 96 43 80 92

*Includes Instruction and operating manual in English. Other languages are available on request.

Description Grundfos product no.

Battery back-up 96 00 25 20Flashing beacon for external alarm indication 62 50 00 20Alarm horn for external alarm indication (outdoor installation) 62 50 00 21Alarm horn for external alarm indication (indoor installation) 62 50 00 22Hour counter [230 V] 96 00 25 14Hour counter [400 V] 96 00 25 15Start counter [230 V] 96 00 25 16Start counter [400 V] 96 00 25 17Combined hour and start counter [230 V] 96 00 25 18Combined hour and start counter [400 V] 96 00 25 1925 [A] external mains switch for supply cable 96 00 25 1140 [A] external mains switch for supply cable 96 00 25 1280 [A] external mains switch for supply cable 96 00 25 13LC-Ex4 96 44 03 00

57

Page 58: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

58

Accessories

AP

Free-standing installation or portable

Installation on auto-coupling

Vertical dry installation (D)

Installation on auto-coupling

TM0

1 25

42 2

09

8TM

01

2543

20

98

AP30AP51AP51 VortexAP80APG

12

10

11

13

AP30AP51AP51 VortexAPG

17

18

14

25

26

16

22

25

25

19

21

R2/DN65

TM0

1 0

749

139

8TM

00

56

16 1

398

28

24

23

20

15

15

24

AP80

19

24

25

26

17

23

25

25

18

20

15

DN80/DN100/DN150/DN200/DN250/DN300/

AP80

Page 59: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Accessories

AP, APG

Level controllers and accessories Pipe dimensions

s

s

TM0

0 3

618

079

4TM

01

69

82 3

99

9TM

01

7286

429

9TM

01

7187

40

99

2929

30

31

32

TM0

1 0

753

219

7

Dimensions DN 1 DN 2 A B C Prod. no.

3 x DN 65, PN 10 65 65 140 140 380 96 00 36 19

DN 65/ 65/ 80, PN 10 65 80 140 235 380 96 00 36 20

3 x DN 100, PN 10 100 100 205 205 611 96 00 36 23

TM0

1 0

898

149

8

Dimensions A Prod. no.

2 x DN 65, PN 10 1300 96 00 38 42

2 x DN 100, PN 10 1300 96 00 38 44

2 x DN 150, PN 10 for 1.5 m pit 1300 96 00 38 45

2 x DN 150, PN 10 for 2.0 m pit 1300 96 00 38 79

TM0

1 0

899

379

7

Dimensions A B C Prod. no.

3 x DN 65, PN 10 620 1300 1920 96 00 38 46

3 x DN 100, PN 10 620 1300 1920 96 00 38 48

3 x DN 150, PN 10 for 2.0 m pit 620 1300 1920 96 00 38 49

3 x DN 150, PN 10 for 2.5 m pit 620 1600 2220 96 00 39 80

C A

B

DN1DN22727

C A

DN 1

DN 2

B

37

A

33

A

38

BAC

34

A B

C

59

Page 60: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

60

Product range

KP

KP 150

KP 250

KP 350

Pump type Voltage Float switchVertical

level switch3 m cable 5 m cable 10 m cable With plug Plug type

Dischargeconnection

Product no.

KP 150 1 x 100 V ! ! Japan Rp 1¼ 01 1B B1 00

KP 150 1 x 100 V ! ! ! Japan Rp 1¼ 01 1B B7 00

KP 150 1 x 115 V ! 10 ft ! USA NPT 1¼ 01 1D C0 01

KP 150 1 x 115 V ! 25 ft ! USA NPT 1¼ 01 1D C2 01

Pump type Voltage Float switchVertical

level switch3 m cable 5 m cable 10 m cable With plug Plug type

Dischargeconnection

Product no.

KP 250 1 x 100 V ! ! Japan Rp 1¼ 01 2B B1 00

KP 250 1 x 100 V ! ! ! Japan Rp 1¼ 01 2B B7 00

KP 250 1 x 115 V 10 ft ! USA NPT 1¼ 01 2D C0 01

KP 250 1 x 115 V 25 ft ! USA NPT 1¼ 01 2D C2 01

KP 250 1 x 220 V ! ! Rp 1¼ 01 2G 66 00

KP 250 1 x 220 V ! ! Rp 1¼ 01 2G 64 00

KP 250 1 x 220 V ! ! Rp 1¼ 01 2G 68 00

KP 250 1 x 220 V ! ! Rp 1¼ 01 2G 69 00

KP 250 3 x 200 V ! Rp 1¼ 01 2F 61 00

Pump type Voltage Float switchVertical

level switch3 m cable 5 m cable 10 m cable With plug Plug type

Dischargeconnection

Product no.

KP 350 1 x 100 V ! ! Japan Rp 1¼ 01 3B B1 00

KP 350 1 x 100 V ! ! ! Japan Rp 1¼ 01 3B B7 00

KP 350 1 x 115 V 10 ft ! USA NPT 1¼ 01 3D C0 01

KP 350 1 x 115 V 25 ft ! USA NPT 1¼ 01 3D C2 01

KP 350 1 x 220 V ! ! Rp 1¼ 01 3G 66 00

KP 350 1 x 220 V ! ! Rp 1¼ 01 3G 64 00

KP 350 1 x 220 V ! ! Rp 1¼ 01 3G 68 00

KP 350 1 x 220 V ! ! Rp 1¼ 01 3G 69 00

KP 350 3 x 200 V ! Rp 1¼ 01 3F 61 00

Page 61: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Product range

AP12, AP30

AP12

AP30

Pump type VoltageControl boxwith 0.8 m

supply cableLevel switch 10 m cable 3 m cable Product no.

AP12.40.04.A1 1 x 220 - 230 V ! 96 02 39 21

AP12.40.04.A1 1 x 220 - 230 V ! ! 96 02 39 22

AP12.40.04.1 1 x 220 - 230 V ! 96 02 39 23

AP12.40.04.3 3 x 380 - 440 V ! 96 01 10 29

AP12.40.04.A3 3 x 380 - 440 V ! ! ! 96 01 10 42

AP12.40.04.3 3 x 200 - 220 V ! 96 01 10 27

AP12.40.04.A3 3 x 200 - 220 V ! ! ! 96 01 10 40

AP12.40.06.A1 1 x 220 - 230 V ! ! 96 01 06 54

AP12.40.06.1 1 x 220 - 230 V ! 96 01 06 59

AP12.40.06.3 3 x 380 - 440 V ! 96 00 17 76

AP12.40.06.A3 3 x 380 - 440 V ! ! ! 96 01 09 38

AP12.40.06.3 3 x 200 - 220 V ! 96 01 08 95

AP12.40.06.A3 3 x 200 - 220 V ! ! ! 96 01 09 37

AP12.40.08.A1 1 x 220 - 230 V ! ! 96 01 06 60

AP12.40.08.1 1 x 220 - 230 V ! 96 01 06 65

AP12.40.08.3 3 x 380 - 440 V ! 96 01 06 41

AP12.40.08.A3 3 x 380 - 440 V ! ! ! 96 01 09 41

AP12.40.08.3 3 x 200 - 220 V ! 96 01 08 96

AP12.40.08.A3 3 x 200 - 220 V ! ! ! 96 01 09 40

AP12.50.11.A1 1 x 220 - 230 V ! ! 96 01 06 78

AP12.50.11.1 1 x 220 - 230 V ! 96 01 06 82

AP12.50.11.3 3 x 380 - 440 V ! 96 01 06 42

AP12.50.11.A3 3 x 380 - 440 V ! ! ! 96 01 09 44

AP12.50.11.3 3 x 200 - 220 V ! 96 01 08 97

AP12.50.11.A3 3 x 200 - 220 V ! ! ! 96 01 09 43

Pump type VoltageControl boxwith 0.8 m

supply cableLevel switch 10 m cable Product no.

AP30.50.09.1.V 1 x 230 V ! ! 96 00 34 68

AP30.50.09.A1.V 1 x 230 V ! ! ! 96 00 34 69

AP30.50.09.3.V 3 x 230 V ! 96 00 34 70

AP30.50.09.3.V 3 x 380 V ! 96 00 34 71

AP30.50.09.3.V 3 x 460 V ! 96 00 34 72

AP30.50.13.1.V 1 x 230 V ! ! 96 00 34 73

AP30.50.13.A1.V 1 x 230 V ! ! ! 96 00 34 74

AP30.50.14.3.V 3 x 230 V ! 96 00 34 75

AP30.50.09.3.V 3 x 380 V ! 96 00 34 76

AP30.50.09.3.V 3 x 460 V ! 96 00 34 77

61

Page 62: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

62

Product range AP35, AP35B

, AP50, AP50B

AP35

AP35B

AP50

AP50B

Pump type VoltageControl boxwith 0.8 m

supply cableLevel switch 10 m cable 3 m cable Product no.

AP35.40.06.A1.V 1 x 220 - 230 V ! ! 96 01 06 66

AP35.40.06.1.V 1 x 220 - 230 V ! 96 01 06 71

AP35.40.06.3.V 3 x 380 - 440 V ! 96 01 06 43

AP35.40.06.A3.V 3 x 380 - 440 V ! ! ! 96 01 09 47

AP35.40.06.3.V 3 x 200 - 220 V ! 96 01 08 98

AP35.40.06.A3.V 3 x 200 - 220 V ! ! ! 96 01 09 46

AP35.40.08.A1.V 1 x 220 - 230 V ! ! 96 01 06 72

AP35.40.08.1.V 1 x 220 - 230 V ! 96 01 06 77

AP35.40.08.3.V 3 x 380 - 440 V ! 96 01 06 44

AP35.40.08.A3.V 3 x 380 - 440 V ! ! ! 96 01 09 50

AP35.40.08.3.V 3 x 200 - 220 V ! 96 01 08 99

AP35.40.08.A3.V 3 x 200 - 220 V ! ! ! 96 01 09 49

Pump type Voltage Float switch 10 m cable 5 m cable With plug Product no.

AP35B.50.06.1.V 1 x 220-230 V ! ! 96 00 45 69

AP35B.50.06.A1.V 1 x 220-230 V ! ! ! 96 00 45 68

AP35B.50.06.3.V 3 x 200-220 V ! 96 00 45 71

AP35B.50.08.1.V 1 x 220-230 V ! ! 96 00 45 81

AP35B.50.08.A1.V 1 x 220-230 V ! ! ! 96 00 45 80

AP35B.50.08.3.V 3 x 200-220 V ! 96 00 45 83

Pump type VoltageControl boxwith 0.8 m

supply cableLevel switch 10 m cable 3 m cable Product no.

AP50.50.08.A1.V 1 x 220 - 230 V ! ! 96 01 06 84

AP50.50.08.1.V 1 x 220 - 230 V ! 96 01 06 88

AP50.50.08.3.V 3 x 380 - 440 V ! 96 01 06 47

AP50.50.08.A3.V 3 x 380 - 440 V ! ! ! 96 01 09 53

AP50.50.08.3.V 3 x 200 - 220 V ! 96 01 09 00

AP50.50.08.A3.V 3 x 200 - 220 V ! ! ! 96 01 09 52

AP50.50.11.A1.V 1 x 220 - 230 V ! ! 96 01 06 90

AP50.50.11.1.V 1 x 220 - 230 V ! 96 01 06 94

AP50.50.11.3.V 3 x 380 - 440 V ! 96 01 06 45

AP50.50.11.A3.V 3 x 380 - 440 V ! ! ! 96 01 09 56

AP50.50.11.3.V 3 x 200 - 220 V ! 96 01 09 01

AP50.50.11.A3.V 3 x 200 - 220 V ! ! ! 96 01 09 55

Pump type Voltage Float switch 10 m cable 5 m cable With plug Product no.

AP50B.50.08.1.V 1 x 220-230 V ! ! 96 00 45 93

AP50B.50.08.A1.V 1 x 220-230 V ! ! ! 96 00 45 92

AP50B.50.08.3.V 3 x 200-220 V ! 96 00 45 95

AP50B.50.11.1.V 1 x 220-230 V ! ! 96 00 46 05

AP50B.50.11.A1.V 1 x 220-230 V ! ! ! 96 00 46 04

AP50B.50.11.3.V 3 x 200-220 V ! 96 00 46 07

AP50B.50.15.3.V 3 x 200-220 V ! 96 00 46 11

Page 63: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

Product range AP51,

AP51 Vortex

AP51 with single-vane impeller

AP51 Vortex impeller

Pump type VoltageControl boxwith 0.8 m

supply cableLevel switch 10 m cable Product no.

AP51.65.09.1 1 x 230 V ! ! 96 00 34 93

AP51.65.09.A1 1 x 230 V ! ! ! 96 00 34 94

AP51.65.09.3 3 x 230 V ! 96 00 34 95

AP51.65.09.3 3 x 380 V ! 96 00 34 96

AP51.65.09.3 3 x 460 V ! 96 00 34 97

AP51.65.13.1 1 x 230 V ! ! 96 00 35 57

AP51.65.13.A1 1 x 230 V ! ! ! 96 00 35 58

AP51.65.14.3 3 x 230 V ! 96 00 35 59

AP51.65.14.3 3 x 380 V ! 96 00 35 60

AP51.65.14.3 3 x 460 V ! 96 00 35 61

AP51.65.15.3 3 x 230 V ! 96 00 35 62

AP51.65.15.3 3 x 380 V ! 96 00 35 63

AP51.65.15.3 3 x 460 V ! 96 00 35 64

AP51.65.22.3 3 x 230 - 380 V ! 96 00 35 65

AP51.65.22.3 3 x 460 V ! 96 00 35 66

AP51.65.23.3 3 x 230 - 380 V ! 96 00 35 67

AP51.65.23.3 3 x 460 V ! 96 00 35 68

AP51.65.34.3 3 x 230 - 380 V ! 96 00 35 71

AP51.65.34.3 3 x 460 V ! 96 00 35 72

AP51.65.35.3 3 x 230 - 380 V ! 96 00 35 69

AP51.65.35.3 3 x 460 V ! 96 00 35 70

Pump type VoltageControl boxwith 0.8 m

supply cableLevel switch 10 m cable Product no.

AP51.65.14.1.V 1 x 230 V ! ! 96 00 34 78

AP51.65.14.A1.V 1 x 230 V ! ! ! 96 00 34 79

AP51.65.14.3.V 3 x 230 V ! 96 00 34 80

AP51.65.14.3.V 3 x 380 V ! 96 00 34 81

AP51.65.14.3.V 3 x 460 V ! 96 00 34 82

AP51.65.15.3.V 3 x 230 - 380 V ! 96 00 34 83

AP51.65.15.3.V 3 x 460 V ! 96 00 34 84

AP51.65.23.3.V 3 x 230 - 380 V ! 96 00 34 85

AP51.65.23.3.V 3 x 460 V ! 96 00 34 86

AP51.65.34.3.V 3 x 230 - 380 V ! 96 00 34 87

AP51.65.34.3.V 3 x 460 V ! 96 00 34 88

AP51.65.35.3.V 3 x 230 - 380 V ! 96 00 34 89

AP51.65.35.3.V 3 x 460 V ! 96 00 34 90

AP51.65.36.3.V 3 x 230 - 380 V ! 96 00 34 91

AP51.65.36.3.V 3 x 460 V ! 96 00 34 92

63

Page 64: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

64

Product range

AP80, APG

AP80

APG

Pump type Voltage 10 m cable Product no.

AP80.100.15 3 x 230 V ! 96 00 45 00

AP80.100.15 3 x 380 V ! 96 00 45 01

AP80.100.15 3 x 400 V ! 96 00 45 02

AP80.100.15 3 x 460 V ! 96 00 45 03

AP.80.100.21 3 x 230 V ! 96 00 45 04

AP.80.100.21 3 x 380 V ! 96 00 45 05

AP.80.100.21 3 x 400 V ! 96 00 45 06

AP.80.100.21 3 x 460 V ! 96 00 45 07

AP80.100.27 3 x 230 V ! 96 00 45 08

AP80.100.27 3 x 380 V ! 96 00 45 09

AP80.100.27 3 x 400 V ! 96 00 45 10

AP80.100.27 3 x 460 V ! 96 00 45 11

AP80.100.35 3 x 230 V ! 96 00 45 12

AP80.100.35 3 x 380 V ! 96 00 45 13

AP80.100.35 3 x 400 V ! 96 00 45 14

AP80.100.35 3 x 460 V ! 96 00 45 15

AP80.100.47 3 x 230 V ! 96 00 45 16

AP80.100.47 3 x 380 V ! 96 00 45 17

AP80.100.47 3 x 400 V ! 96 00 45 18

AP80.100.47 3 x 460 V ! 96 00 45 19

AP80.100.65 3 x 230 V ! 96 00 45 20

AP80.100.65 3 x 380 V ! 96 00 45 21

AP80.100.65 3 x 400 V ! 96 00 45 22

AP80.100.65 3 x 460 V ! 96 00 45 23

AP80.100.74 3 x 230 V ! 96 00 45 24

AP80.100.74 3 x 380 V ! 96 00 45 25

AP80.100.74 3 x 400 V ! 96 00 45 26

AP80.100.74 3 x 460 V ! 96 00 45 27

AP80.100.87 3 x 230 V ! 96 00 45 28

AP80.100.87 3 x 380 V ! 96 00 45 29

AP80.100.87 3 x 400 V ! 96 00 45 30

AP80.100.87 3 x 460 V ! 96 00 45 31

AP80.100.107 3 x 230 V ! 96 00 45 32

AP80.100.107 3 x 380 V ! 96 00 45 33

AP80.100.107 3 x 400 V ! 96 00 45 34

AP80.100.107 3 x 460 V ! 96 00 45 35

Pump type VoltageControl box

with 0.8 m supply cableLevel switch 10 m cable Product no.

APG.50.12.1 1 x 230 V ! ! 96 00 35 16

APG.50.12.A1 1 x 230 V ! ! ! 96 00 35 17

APG.50.11.3 3 x 230 V ! 96 00 35 84

APG.50.11.3 3 x 380 V ! 96 00 35 85

APG.50.11.3 3 x 460 V ! 96 00 35 20

APG.50.18.1 1 x 230 V ! ! 96 00 35 21

APG.50.18.A1 1 x 230 V ! ! ! 96 00 35 22

APG.50.19.3 3 x 230 - 380 V ! 96 00 35 23

APG.50.19.3 3 x 460 V ! 96 00 35 24

APG.50.30.1 1 x 230 V ! ! 96 00 35 25

APG.50.30.A1 1 x 230 V ! ! ! 96 00 35 26

APG.50.29.3 3 x 230 - 380 V ! 96 00 35 27

APG.50.29.3 3 x 460 V ! 96 00 35 28

APG.50.33.1 1 x 230 V ! ! 96 00 35 29

APG.50.30.A1 1 x 230 V ! ! ! 96 00 35 30

Page 65: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

65

Page 66: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

66

Page 67: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

67

Page 68: GRUNDFOS DATA BOOKLETType key for KP pumps Page 5 Construction Page 6 Installation Page 6 Sectional drawing Page 6 Performance curves Technical data KP Page 7 AP12 Page 10 AP30 Page

www.grundfos.com

V7 11 82 80 03 03GBRepl. V7 11 82 80 09 00 Subject to alterations.

GRUNDFOS A/S . DK-8850 Bjerringbro . DenmarkTelephone: +45 87 50 14 00.

Being responsible is our foundationThinking ahead makes it possible

Innovation is the essence