GRUNDFOS DATA BOOKLET
AP, KPWastwater pumps
60 Hz
2
Contents
General dataPerformance range Page 3Applications Page 4Examples of application Page 4Pump overview Page 5Type key for AP pumps Page 5Type key for KP pumps Page 5Construction Page 6Installation Page 6Sectional drawing Page 6
Performance curves Technical dataKP Page 7AP12 Page 10AP30 Page 14AP35 Page 18AP35B Page 22AP50 Page 25AP50B Page 29AP51 Page 32AP51 Vortex Page 36Control box Page 40AP80 Page 41APG Page 47
AccessoriesLC 107, LCD 107 Page 51LC 108, LCD 108 Page 52Level switches Page 53Accessories for AP, KP stainless steel pumps Page 54Accessories for cast iron AP pumps Page 55Level controllers and accessories Page 57Free-standing installation or portable Page 58Installation on auto-coupling Page 58Vertical dry installation (D) Page 58Level controllers and accessories Page 59Pipe dimensions Page 59
Product rangeKP Page 60AP12, AP30 Page 61AP35, AP35B, AP50, AP50B Page 62AP51, AP51 Vortex Page 63AP80, APG Page 64
3
General data Wastewater pumpsAP, KP
Performance range
TM0
0 8
60
3 47
99
TM0
0 8
60
4 47
99
TM0
1 9
566
210
0
0 1 2 3 4 5 6 7 8 9 Q [l/s]
0
2
4
6
8
10
12
14
16
H[m]
0 8 16 24 32 Q [m³/h]
Drainage pumps
KP AP12
0 1 2 3 4 5 6 7 8 Q [l/s]
0
2
4
6
8
10
12
14
H[m]
0 8 16 24 Q [m³/h]
Wastewater andsewage pumps
AP50AP35
0 1 2 3 4 5 6 7 8 Q [l/s]
0
2
4
6
8
10
12
14
16
H[m]
0 8 16 24 Q [m³/h]
Wastewater andsewage pumps
AP50B
AP35B
TM0
0 8
60
2 47
99
TM0
0 8
60
5 47
99
TM0
1 77
18 2
100
0 2 4 6 8 10 12 14 16 18 Q [l/s]
0
4
8
12
16
20
24
28
H[m]
0 20 40 60 Q [m³/h]
Wastewater andsewage pumps
AP30
AP51
0 1 2 3 4 5 6 Q [l/s]
0
10
20
30
40
50
H[m]
0 5 10 15 20 Q [m³/h]
Grinder pumps
APG
0 5 10 15 20 25 30 35 40 45 50 Q [l/s]
0
5
10
15
20
25
30
H[m]
0 40 80 120 160 Q [m³/h]
Sewage pumps
AP80
4
General data Wast
ewater pumpsAP, KPApplicationsThe KP and AP pumps are suitable for temporary as wellas permanent free-standing installation. FurthermoreAP pumps are suitable for installation on an auto-coupling at the bottom of a pit with guide rails going tothe top.
As an option the AP80 pumps are available for dry pitinstallation.
The pumps are designed for intermittent operation.
pH value for KP pumps: 4 to 9.pH value for AP pumps: 4 to 10.
Maximum density: 1.100 kg/m3.Maximum installation depth below water level: 10 m.
For permanent installation, level controllers are avail-able: LC for one-pump installations and LCD for two-pump installations.
Examples of application
KP
AP1
2
AP3
0
AP3
5
AP3
5B
AP5
0
AP5
0B
AP5
1
AP5
1V
ort
ex
AP8
0
APG
Max. liquid temperature 50°C 55°C 40°C 55°C 40°C 55°C 40°C 40°C 40°C 40°C 40°C
Pumping of wastewater from rivers and lakes ! ! ! ! ! ! " ! "
Pumping of drainage water and flood water ! ! ! ! ! ! ! " ! "
Pumping of surface rainwater ! ! ! ! ! ! ! ! ! "
Pumping of ditch and excavation drainage water ! ! ! ! ! ! ! !
Pumping of drainage water from garage sprinkler systems " ! " " " " ! " "
Mobile use for contractors, installers and industry ! ! ! ! ! ! ! ! "
Filling/emptying of containers ! ! ! ! ! ! ! ! !
Transfer of liquids in industry, etc. ! ! ! ! ! ! ! ! !
Pumping of effluents from tunnels, underground garages etc. ! ! ! ! ! ! ! ! !
Pumping of sewage from single and multi-family dwellings ! !
Pressurized pumping of sewage from camp sites, service areas and remote buildings !
Pressurized pumping of sewage from public buildings and small factories !
Pumping of sewage from private toilets, showers, swimming pools etc. below sewer level
! ! ! ! " !
Pumping of wastewater from single and multi-family homes, camp sites and sports stadiums
" " " ! !
Pumping of sewage in municipal applications ! !
Pumping of sewage from hotels, restaurants, cinemas, schools and public buildings ! !
Pumping of wastewater from underground stations and public swimming pools ! !
● = Recommended pump type❍ = Alternative pump type
General data Wastew
ater pumpsAP, KPPump overview
Type key for AP pumps
Type key for KP pumps
Pump rangeFree passage
[mm]Impeller type Number of motor poles
KP 10 Semi-open 2
AP12 12 Semi-open 2
AP30 30 Open single-channel 2
AP35 35 Vortex 2
AP35B 35 Vortex 2
AP50 50 Vortex 2
AP50B 50 Vortex 2
AP51 50 Single-channel 2
AP51 Vortex 51 Vortex 2
AP80 80 Single-channel 4
APG grinder pumpsCutter system with semi-open impeller
2
Example AP 30 .50 .13 A 1 .V
AP: AP pump range
12-80:G:
Max. free passage [mm]With cutter system (APG grinder pumps)
B Basic
40-80: Nominal diameter of discharge port [mm]
0.4 - 107: Power output P2/100 [W]
A: With level switch
1: none or 3:
Single-phase voltage supplyThree-phase voltage supply
V: With vortex impeller
Example KP 150 A -1
KP: Pump range
150:250:
150 W motor power output250 W motor power output350 W motor power output350:
A:AV:M:
With float switchWith vertical level switchWithout level switch
1:3:
Single-phase voltage supplyThree-phase voltage supply
5
6
General data Wast
ewater pumpsAP, KPConstructionVertical, single-stage, submersible centrifugal pumpswith horizontal or vertical discharge port designed forfree-standing installation or installation by means of anauto-coupling guide rail system or for pit installation.
The pumps are directly connected to an asynchronoussubmersible motor for
• 1 x 230 V ±10%, 60 Hz
• 3 x 230 V ±10%, 60 Hz
• 3 x 380 V ±10%, 60 Hz or
• 3 x 460 V ±10%, 60 Hz.
Enclosure class: IP 68.Insulation class: F (155°C).
Stainless steel pumps
Single-phase pumps incorporate thermal overloadprotection and require no additional motor protection.Three-phase pumps must be connected to a motorstarter.
Cast iron pumps
APG pumps have a built-in thermal protection whichcuts off the motor in case of overload. The motor restartsautomatically.
Some three-phase pumps have a thermal switch in themotor windings.
InstallationThe pumps are suitable for free-standing installation aswell as installation on an auto-coupling guide railsystem, which is available as an accessory.
Pumps in permanent submersible installations can beinstalled by means of a stationary auto-coupling at thebottom of the pit. Two guide rails going to the top of thepit ensure that the pump is positioned correctly whenlowered from the top of the pit down to the auto-coupling and connected to the pipe system. Due to thissystem, the pump can easily be pulled up for service.
For free-standing installation the AP80 and APG pumpsmust be fitted with a base stand, see accessories.
Sectional drawing
TM0
1 42
60
50
98
AP80.100.21
Technical data Dra
inage pumpsKPKP
The KP pump is designed for liquid transfer and drainageof clean or slightly dirty wastewater with the pumpcompletely or partly submerged in the liquid.
• drainage of cellars or buildings,
• pumping of domestic wastewater without toilet waste,
• groundwater lowering,
• emptying applications, eg. in pools, tanks and vessels and
• pumping applications within agriculture, dairyindustry, horticulture and process industry.
ApprovalsZ-53.3-408 according to Institut für Bautechnik, Berlin.
Pumped liquidsPumps without level switch or with float switch:The pump is suitable for the pumping of
• clean, non-aggressive water and
• slightly dirty (grey) wastewater.
If the pump has been used for other liquids than cleanwater, it should be flushed through with clean waterimmediately after use. The open impeller constructionensures a free passage of solids up to a diameter of ø10mm.
Pumps with vertical level switch:The pump must only be used for the pumping of cleanground water and drain water.
Operating rangeInstallation depth: Max. 10 metres below liquid
level.Min. liquid temperature: 0°C.
Max. liquid temperature at continuous operation: 50°C.
During continuous pumping the suction strainer mustalways be completely covered by the liquid.
Max. liquid temperature: 70°C for periods not ex-ceeding 2 minutes at intervals of at least 30 minutes.
DischargeKP 150, KP 250 and KP 350: Rp 1¼.
Pump sleeve and housingSingle-stage, submersible, stainless steel, drainagepump in a robust design with upwards-pointingdischarge port placed on top of the pump.
The water enters the pump through the holes of thesuction strainer preventing the passage of large solids.The sturdy impeller has single curved vanes withbevelled front edges that prevent fibres from jammingthe impeller. The guide vanes in the pump housing notonly guide the liquid but also lift sand grains into theliquid flow and thus prevent blocking by sand.
The outer casing is made in one piece. The mains cableand the cable of the level switch are combined in onevulcanized and watertight plug, which is secured to thesocket of the hermetically sealed stator housing.
MotorThe motor is a single- or three-phase, asynchronouscanned motor with liquid-filled rotor chamber andwater lubricated bearings. The motor is cooled by thepumped liquid around the motor.
Enclosure class: IP 68.Insulation class: F.
The motor incorporates automatic overload protectionwhich cuts out the motor in case of overload. When ithas cooled to normal temperature, the motor will restartautomatically.
Note: The motors for 3 x 200 V do not incorporate over-load protection.
Materials
TM0
1 71
45 4
09
9
Components Materials DIN W.-Nr. AISI
Outer casing Stainless steel 1.4301 304
Pump housing Stainless steel 1.4301 304
Suction strainer Stainless steel 1.4301 304
Impeller Stainless steel 1.4301 304
Shaft Stainless steel 1.4057 431
Stator housing Stainless steel 1.4301 304
Guide vanes Stainless steel 1.4301 304
Bearings Carbon
O-rings Seal rings
NBR
Cables H07 RN-F
Performance curves Technical dataKP
7
8
Technical data Dr
ainage pumpsKPWith float switch With vertical level switch
TM0
1 77
17 4
799
0 2 4 6 8 10 12 14 Q [m³/h]
0
1
2
3
4
5
6
7
8
9
10
H[m]
0 1 2 3 4 Q [l/s]
0
20
40
60
80
p[kPa]
KP60 Hz
KP 250
KP 150
KP350
Pump type VoltageP1
[W]p2
[W]In
[A]
Dimensions [mm] Weight[kg]H B1 B2 L1 L2 L3
KP 150 1 x 100 V 310 150 3.2 225 149 30 350# 400 70 6.3
KP 150 1 x 115 V 300 150 2.9 225 149 30 350# 400 70 6.3
KP 250 1 x 100 V 542 250 5.7 225 149 31 350# 400 70 7.2
KP 250 1 x 115 V 480 250 4.9 225 149 31 350# 400 70 7.2
KP 250 1 x 220 V 480 250 2.5 225 149 31 350# 400 70 7.2
KP 250 3 x 200 V 440 250 4.5 225 149 31 350# 400 70 7.2
KP 350 1 x 100 V 800 350 8.2 235 149 31 350# 410 70 8.0
KP 350 1 x 115 V 850 350 8.2 235 149 31 350# 410 70 8.0
KP 350 1 x 220 V 750 350 3.2 235 149 31 350# 410 70 8.0
KP 350 3 x 200 V 690 350 2.4 235 149 31 350# 410 70 8.0
# With vertical level switch : 250 mm.
TM0
0 1
803
159
7
1
2
H min
. L
min. L
min. L3
1
241
B
B
Rp 1 /
TM0
1 11
09
10
98
•
•
••
•
•
•
•
•
•
•
•
•
•
•
•
••
•
•••
•
•
•
••
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
• ••
•
•
•
••
•
••
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
••
•
••
•
• • •
•
•
•
•
•••
•
•
•
•
••
•
•
••
•
•
•
•
•
•
•
• •
••
•
•
••
•
•
•
•
••
•
•
•
•
•
•
•
•
•
•
•
•••
••
••
• •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
• •
••
•
•
••
•
•
•
•••
••
•
•
• ••••
•
•
•
••
••
•
••
••
•
••
• • • •
•
•
• •
•
•
•
••
•
• •
••
•
•
••
•
•
•
•••
••
•
•
• ••••
•
•
•
••
••
•
••
••
•
••
• • • •
•
•
• •
•
•
•
••
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
• •••
•
•
•
••
••
•
••
••
•
••
• •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
••
••
•
•
•
•
•
•••
•
•
•
•
••
•
•
••
•
•
•
•
•
•
•
•
••
•
•
•
•
•
•
•
•
•
•
•
••
••
••
• •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
• ••
•
•
•
••
•
•
•
•
•
•
•
•
•
•
•
••
•
•
•
•
•
•
•
•
•
••
•
•
•
•
•
•
•
•
•
•
•
•
••
•
•
•
•
••
•
•
•
••
••
••
• •
•
•
•
•
•
••
•
•
•
•
•
•
••
•
•
••
•
•
•
•
•
•
•
•
•
•
•
•
•
•
••
•
ø 250 mm
400 mm
Technical data Dra
inage pumpsKPInstallationPumps without level switch or with float switch can beused in vertical position with the discharge port upper-most or in horizontal or tilted position with thedischarge port as the highest point of the pump.
Pumps with vertical level switch must be used in verticalposition.
The KP pump is well suited for permanent installation.
Level switchesA level switch, which gives impulses to start/stopbetween two levels of liquid, is connected to pumpsintended for automatic operation. This type of installa-tion requires a non-return valve in the discharge pipe orin the pump. The pumps are available with two differenttypes of level switches.
Min. liquid level: – manual operation: 14 mm.– automatic operation: See below.
Pumps with float switch:
A clamp on the handle of the pump holds the cable of thelevel switch. The difference in level between start andstop can be adjusted by changing the free cable lengthbetween the handle of the pump and the level switch.
Dimensions for KP 350 are marked with "#".
Pumps with vertical level switch:
For pumps with vertical level switch, the difference inlevel between start and stop is not adjustable.
Dimensions for KP 350 are marked with "#".
TM0
0 1
548
049
3TM
00
149
2 46
97
TM0
0 1
552
259
9TM
01
110
8 32
97
•• • • • • • • • • • • • •• • • • • • • • • • • •• • • • • • • • • • •• • • • • • • • • • • •• • • • • • • • • • •• • • • • • • • • •• • • • • • • • • • •• • • • • • • • • •• • • • • • • • • •• • • • • • • • • •• • • • • • • • •• • • • • • • •• • • • • • • •• • • • • • • •
Max.150mm
Start
Stop
100mm
225mm
Float switch
100 mm110 mm#
225 mm
Max. 150 mm
Start
Stop80 mm
100 mm
80 mm
100 mm110 mm#
Vertical level switch
9
10
Technical data
AP12AP12
The AP12 pump is a single-stage submersible pumpdesigned for the pumping of drainage water. The pumpis suitable for the following applications
• ground water lowering,
• pumping in drainage pits,
• pumping in surface water pits with inflow from roof gutters, shafts, tunnels, etc.,
• emptying of ponds, tanks, etc. and
• maximum particle size: 12 mm.
ApprovalsPA-I no. 4104 VDE.
Automatic operationThe pump is available for automatic as well as manualoperation and can be installed in a permanent installa-tion or used as a portable pump. The pump is available:
• with level switch fitted for automatic ON/OFF opera-tion between two liquid levels (single-phase pumps);
• with separate level switch and control box for auto-matic ON/OFF operation between two liquid levels (three-phase pumps);
• without level switch for manual ON/OFF operation.
Pumps fitted with level switches can also be used formanual ON/OFF operation. In this case the level switchmust be secured in an upwards-pointing position.
Pump sleeve and housingThe stainless steel pump sleeve is made in one piece andequipped with an insulated carrying handle. The suctionstrainer is clipped on to the pump housing and can easilybe removed for maintenance. The strainer not onlyprevents the passage of large solids but also ensures aslow flow into the pump. As a result, most impuritieswill be deposited outside the pump.
The stainless steel pump housing is fitted with aninternal riser pipe ensuring high efficiency. The riser pipehas a number of holes which enable efficient cooling ofthe motor during operation. The cable entry is of thesocket and plug connection type, which makes quick andeasy dismantling possible.
Discharge portAll AP12 pumps have a threaded vertical dischargeport.
AP12.40: Rp 1½.AP12.50: Rp 2.
Shaft and bearingsThe shaft is made of stainless steel and rotates in main-tenance-free prelubricated ball bearings.
ImpellerThe stainless steel impeller is a semi-open impeller withL-shaped blades and a clearance of 12 mm. The bladesare curved backwards to reduce any harmful effect fromsolid particles and to reduce the power consumption.
Shaft sealThe shaft seal is a combination of a mechanical shaftseal of the bellows type and a lip seal with 60 ml oilbetween them. The mechanical shaft seal of AP12 pumpshas silicone carbide seal faces.
Motor cableStandard pumps 10 m: H07RNF.
Materials
TM0
0 5
738
089
5
TM0
0 5
477
400
0
Description Materials DIN W.-Nr. AISI
Pump housing Stainless steel 1.4301 304
Riser pipe Stainless steel 1.4301 304
Impeller Stainless steel 1.4301 304
Pump sleeve Stainless steel 1.4401 316
Shaft Stainless steel 1.4305
Bearings Heavy-duty prelubricated ball bearings
O-rings NBR rubber
Screws Stainless steel 1.4301 304
Oil Shell Ondina 15, non-toxic
Performance curves
AP12TM0
0 7
213
479
9
0 5 10 15 20 25 30 35 Q [m³/h]
0.0
0.4
0.8
1.2
1.6
2.0
[kW]P1
0.0
0.8
1.6
2.4
P1[hp]
.40.04.1
.40.06.1
.40.06.3
.40.08.1
.40.08.3
.50.11.1
.50.11.3
0 5 10 15 20 25 30 35 Q [m³/h]
0
2
4
6
8
10
12
14
16
[m]H
0 2 4 6 8 10 Q [l/s]
0
40
80
120
160
p[kPa] AP12
60 HzISO 9906 +/- 10%
.40.04
.40.06.1.40.06.3
.40.08.1.40.08.3
.50.11.1.50.11.3
11
12
Technical data
AP12.8
.8
6
6
0
0
0
0
.2
.2
.3
.3
.3
.3
.7
.7
9
9
9
9
TM0
0 5
523
09
95
S
B
A
Pump type VoltageP1
[kW]p2
[kW]In
[A]Cos ϕ
Dimensions [mm]Weight
[kg]A B S
AP12.40.04.1 1 x 220 - 230 V 0.8 0.4 3.7 0.99 6.0 321 216 Rp 1½ 10.0 - 10
AP12.40.04.A1 1 x 220 - 230 V 0.8 0.4 3.7 0.99 6.0 321 216 Rp 1½ 10.0 - 10
AP12.40.04.3 3 x 200 - 220 V 0.8 0.4 2.4 0.91 6.0 321 216 Rp 1½ 9.7 - 12.0
AP12.40.04.A3 3 x 200 - 220 V 0.8 0.4 2.4 0.91 6.0 321 216 Rp 1½ 9.7 - 12.0
AP12.40.04.3 3 x 380 - 400 V 0.8 0.4 1.1 0.83 6.0 321 216 Rp 1½ 9.7 - 12.0
AP12.40.04.A3 3 x 380 - 400 V 0.8 0.4 1.1 0.83 6.0 321 216 Rp 1½ 9.7 - 12.0
AP12.40.06.1 1 x 220 - 230 V 1.0 0.6 4.4 0.99 3.8 321 216 Rp 1½ 10.8 - 11.
AP12.40.06.A1 1 x 220 - 230 V 1.0 0.6 4.4 0.99 3.8 321 216 Rp 1½ 10.8 - 11.
AP12.40.06.3 3 x 200 - 220 V 1.0 0.6 3.2 0.91 6.0 321 216 Rp 1½ 10.7 - 13.
AP12.40.06.A3 3 x 200 - 220 V 1.0 0.6 3.2 0.91 6.0 321 216 Rp 1½ 10.7 - 13.
AP12.40.06.3 3 x 380 - 400 V 0.9 0.6 1.5 0.83 6.0 321 216 Rp 1½ 10.7 - 13.
AP12.40.06.A3 3 x 380 - 400 V 0.9 0.6 1.5 0.83 6.0 321 216 Rp 1½ 10.7 - 13.
AP12.40.08.1 1 x 220 - 230 V 1.3 0.8 5.9 0.99 3.8 346 216 Rp 1½ 12.4 - 13
AP12.40.08.A1 1 x 220 - 230 V 1.3 0.8 5.9 0.99 3.8 346 216 Rp 1½ 12.4 - 13
AP12.40.08.3 3 x 200 - 220 V 1.2 0.8 3.9 0.91 6.0 346 216 Rp 1½ 12.0 - 14
AP12.40.08.A3 3 x 200 - 220 V 1.2 0.8 3.9 0.91 6.0 346 216 Rp 1½ 12.0 - 14
AP12.40.08.3 3 x 380 - 440 V 1.2 0.8 1.8 0.87 6.0 346 216 Rp 1½ 12.0 - 14
AP12.40.08.A3 3 x 380 - 440 V 1.2 0.8 1.8 0.87 6.0 346 216 Rp 1½ 12.0 - 14
AP12.50.11.1 1 x 220 - 230 V 1.8 1.1 9.0 0.98 6.0 357 241 Rp 2 14.9 - 15
AP12.50.11.A1 1 x 220 - 230 V 1.8 1.1 9.0 0.98 6.0 357 241 Rp 2 14.9 - 15
AP12.50.11.3 3 x 200 - 220 V 1.6 1.1 5.9 0.85 6.0 357 241 Rp 2 15.6 - 17.
AP12.50.11.A3 3 x 200 - 220 V 1.6 1.1 5.9 0.85 6.0 357 241 Rp 2 15.6 - 17.
AP12.50.11.3 3 x 380 - 440 V 1.8 1.1 2.7 0.88 6.0 357 241 Rp 2 15.6 - 17.
AP12.50.11.A3 3 x 380 - 440 V 1.8 1.1 2.7 0.88 6.0 357 241 Rp 2 15.6 - 17.
Istart
In---------
Technical data
AP12AP12 installations
TM0
0 5
538
09
95
min. ø500
TM0
0 5
539
09
95
min. ø800
13
14
Technical data
AP30AP30
The pumps are used for pumping wastewater, sludge-containing water, ground water and surface water inplaces such as
• holiday homes,
• single-family houses,
• blocks of flats,
• public buildings,
• factories,
• garages,
• underground car parks and
• car wash areas.
Applications as under AP12, but where a larger impellerclearance is required.
Pump and stator housingThe pump housing and the stator housing are made ofcast iron.
The stator housing is dry, i.e. not oil-filled.
DischargeAll AP30 pumps have a horizontal R 2 discharge port forthreaded connection.
Shaft and bearingsThe shaft is made of stainless steel and rotates in main-tenance-free prelubricated ball bearings.
ImpellerThe impeller is a vortex impeller in cast iron GG 25 witha free passage of 30 mm in the pump housing. Cast ironis chosen as it is resistant towards mechanicallywearing particles.
Shaft sealCombination of mechanical shaft seal and lip seal.
The primary shaft seal have silicon carbide/siliconcarbide seal faces.The secondary shaft seal is a lip seal. The chamberbetween the shaft seals is filled with oil.
Standard pumps: 0.01 litre
Motor cableStandard pumps 10 m: H07RNF.
Materials
Control boxFurther information about control box, float switch, andlevel controller, see page 40.
TM0
1 71
74 4
09
9
TM0
1 26
17 2
09
8
Description Materials DIN W.-Nr. AISI/ASTM
Stator housing Cast iron GG 25 0.6025 ASTM 35B
Pump housing Cast iron GG 25 0.6025 ASTM 35B
Neck ring Bronze
Impeller Cast iron GG 25 0.6025 ASTM 35B
Wear plate Cast iron GG 25 0.6025 ASTM 35B
Shaft Stainless steel 1.4104 AISI 430F
Bearings Heavy-duty prelubricated ball bearings
Screws Stainless steel 1.4301 AISI 304
Oil Shell Ondina 15, non-toxic
Performance curves
AP30TM0
0 7
215
479
9
0 5 10 15 20 25 30 35 Q [m³/h]
0.0
0.4
0.8
1.2
1.6
2.0
[kW]P1
0.0
0.8
1.6
2.4
P1[hp]
09.1.V
09.3.V
14.3.V13.1.V
0 5 10 15 20 25 30 35 Q [m³/h]
0
1
2
3
4
5
6
7
8
9
10
11
12
[m]H
0 2 4 6 8 10 Q [l/s]
0
20
40
60
80
100
p[kPa] AP30.50.
60 HzISO 2548 Annex B
09.1.V
09.3.V
13.1.V
14.3.V
15
16
Technical data
AP30Elbow is an accessory
TM0
1 25
50 2
09
8
S
A
E
B
C
D
Pump type VoltageP1
[kW]P2
[kW]n
[min-1]In
[A]Cos ϕ
Dimensions [mm]Weight
[kg]A B C D E S
AP30.50.09.1.V 1 x 230 V 1.2 0.9 3450 5.4 0.97 3.4 431 312 101 51 175 R 2 26 - 27
AP30.50.09.A1.V 1 x 230 V 1.2 0.9 3450 5.4 0.97 3.4 431 312 101 51 175 R 2 26 - 27
AP30.50.09.3.V 3 x 230 V 1.2 0.9 3450 4.0 0.79 6.0 431 312 101 51 175 R 2 25
AP30.50.09.3.V 3 x 380 V 1.2 0.9 3450 2.3 0.79 6.0 431 312 101 51 175 R 2 25
AP30.50.09.3.V 3 x 460 V 1.2 0.9 3450 1.9 0.79 6.0 431 312 101 51 175 R 2 25
AP30.50.13.1.V 1 x 230 V 1.8 1.3 3450 7.8 0.97 6.0 431 312 101 51 175 R 2 26 - 27
AP30.50.13.A1.V 1 x 230 V 1.8 1.3 3450 7.8 0.97 6.0 431 312 101 51 175 R 2 26 - 27
AP30.50.14.3.V 3 x 230 V 1.8 1.4 3450 5.6 0.84 6.0 431 312 101 51 175 R 2 25
AP30.50.14.3.V 3 x 380 V 1.8 1.4 3450 3.3 0.84 6.0 431 312 101 51 175 R 2 25
AP30.50.14.3.V 3 x 460 V 1.8 1.4 3450 2.7 0.84 6.0 431 312 101 51 175 R 2 25
Istart
In---------
Technical data
AP30AP30 installations
One-pump installation on auto-coupling
Two-pump installation on auto-coupling
TM0
1 25
51 2
09
8
‹
‹
‹
‹
‹
‹
‹
‹ ‹
‹‹
‹
‹‹
‹
‹
‹‹
‹
‹‹
‹
‹‹‹
‹
‹
‹‹
‹‹
‹
‹
‹
‹
‹‹
‹
‹
‹
‹
‹‹
‹
‹
‹
‹
‹‹
‹
‹
‹
‹
‹
‹
‹
‹
‹ ‹
‹‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹‹‹
‹‹
‹
‹ ‹‹
‹‹
‹
‹
‹ ‹‹‹ ‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹‹
‹
‹‹‹
‹
‹
‹‹
‹
‹‹
‹
‹‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹‹‹
‹
‹‹
‹ ‹
‹‹
‹
‹‹
‹
‹
‹‹
‹
‹
‹‹
‹
‹
‹
‹
‹
‹
F
C
A
U
Z
J
G
K L
N O
T
E
S
TM0
1 25
52 2
09
8
‹
‹‹
‹
‹
‹‹
‹
‹
‹
‹‹
‹
‹‹
‹‹
‹
‹‹
‹
‹‹
‹
‹
‹‹
‹‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹ ‹
‹‹
‹
‹‹
‹
‹
‹
‹
‹
‹‹
‹‹
‹
‹‹
‹
‹
‹‹
‹
D
I
M M
R PP
B
Pump type A B C D E F G I J K L M N O P S T U Z
AP30.50.09.1.V ø600 ø600 265 300 45 45 65 115 108 150 400 200 300 700 500 Rp 2 ½" 160 295
AP30.50.09.A1.V ø600 ø600 265 300 45 45 65 115 108 150 400 200 300 700 500 Rp 2 ½" 160 295
AP30.50.09.3.V ø600 ø600 265 300 45 45 65 115 108 150 400 200 300 700 500 Rp 2 ½" 160 295
AP30.50.13.1.V ø600 ø600 265 300 45 45 65 115 108 150 400 200 300 700 500 Rp 2 ½" 160 295
AP30.50.13.A1.V ø600 ø600 265 300 45 45 65 115 108 150 400 200 300 700 500 Rp 2 ½" 160 295
AP30.50.14.3.V ø600 ø600 265 300 45 45 65 115 108 150 400 200 300 700 500 Rp 2 ½" 160 295
Pump type A B C D E F G I J K L M N O P R S T U Z
AP30.50.09.1.V 455 600 265 135 45 45 65 115 108 150 400 200 300 700 335 330 Rp 2 ½" 160 295
AP30.50.09.A1.V 455 600 265 135 45 45 65 115 108 150 400 200 300 700 335 330 Rp 2 ½" 160 295
AP30.50.09.3.V 455 600 265 135 45 45 65 115 108 150 400 200 300 700 335 330 Rp 2 ½" 160 295
AP30.50.13.1.V 455 600 265 135 45 45 65 115 108 150 400 200 300 700 335 330 Rp 2 ½" 160 295
AP30.50.13.A1.V 455 600 265 135 45 45 65 115 108 150 400 200 300 700 335 330 Rp 2 ½" 160 295
AP30.50.14.3.V 455 600 265 135 45 45 65 115 108 150 400 200 300 700 335 330 Rp 2 ½" 160 295
17
18
Technical data
AP35AP35
The AP35 pump is a single-stage submersible pumpdesigned for the pumping of drainage water andeffluent.The pump is suitable for the following applications
• ground water lowering,
• pumping in drainage pits,
• pumping in surface water pits with inflow from roof gutters, shafts, tunnels, etc.,
• emptying of ponds, tanks, etc.,
• pumping of fibre-containing wastewater from laun-dries and industries and
• pumping of domestic wastewater without discharge from water closets.
ApprovalsPA-I no. 4104 VDE.
Automatic operationThe pump is available for automatic as well as manualoperation and can be installed in a permanent installa-tion or used as a portable pump. The pump is available:
• with level switch fitted for automatic ON/OFF opera-tion between two liquid levels (single-phase pumps);
• with separate level switch and control box for auto-matic ON/OFF operation between two liquid levels (three-phase pumps);
• without level switch for manual ON/OFF operation.
Pumps fitted with level switches can also be used formanual ON/OFF operation. In this case the level switchmust be secured in an upwards-pointing position.
Pump sleeve and housingThe stainless steel pump sleeve is made in one piece andequipped with an insulated carrying handle. The suctionstrainer is clipped on to the pump housing and can easilybe removed for maintenance.
The strainer not only prevents the passage of large solidsbut also ensures a slow flow into the pump.
The stainless steel pump housing is fitted with aninternal riser pipe ensuring high efficiency. The riser pipehas a number of holes which enable efficient cooling ofthe motor during operation. The cable entry is of thesocket and plug connection type, which makes quick andeasy dismantling possible.
Discharge portAll AP35 pumps have a threaded vertical discharge port:Rp 1½.
Shaft and bearingsThe shaft is made of stainless steel and rotates in main-tenance-free prelubricated ball bearings.
ImpellerThe stainless steel impeller is a Vortex impeller withL-shaped blades and a clearance of 35 mm (in the pumphousing). The blades are curved backwards to reduce anyharmful effect from solid particles and to reduce thepower consumption.
Shaft sealThe shaft seal is a combination of a mechanical shaftseal of the bellows type and a lip seal with 60 ml oilbetween them. The shaft seal has silicon carbide sealfaces.
Motor cableStandard pumps 10 m: H07RNF.
Materials
TM0
0 5
739
119
5
TM0
0 5
478
400
0
Description Materials DIN W.-Nr. AISI
Pump housing Stainless steel 1.4301 304
Riser pipe Stainless steel 1.4301 304
Impeller Stainless steel 1.4301 304
Pump sleeve Stainless steel 1.4401 316
Shaft Stainless steel 1.4305
Bearings Heavy-duty prelubricated ball bearings
O-rings NBR rubber
Screws Stainless steel 1.4301 304
Cables Neoprene
Oil Shell Ondina 15, non-toxic
Performance curves
AP35TM0
0 7
220
479
9
0 2 4 6 8 10 12 14 16 18 20 Q [m³/h]
0
1
2
3
4
5
6
7
8
9
10
11
12
13
H[m]
0 1 2 3 4 5 6 Q [l/s]
0
20
40
60
80
100
120
p[kPa] AP35.40.
60 HzISO 9906 Annex A
06.1.V
06.3.V
08.1.V
08.3.V
0 2 4 6 8 10 12 14 16 18 20 Q [m³/h]
0.0
0.2
0.4
0.6
0.8
1.0
1.2
P1[kW]
0.0
0.5
1.0
1.5
P1[hp]
08.3.V
08.1.V
06.3.V
06.1.V
TM00
722
0 45
00
19
20
Technical data
AP35TM0
0 5
524
09
95
S
B
A
Pump type VoltageP1
[kW]P2
[kW]In
[A]Cos ϕ
Dimensions [mm]Weight
[kg]A B S
AP35.40.06.1.V 1 x 220 - 230 V 1.2 0.7 3.9 0.97 6.0 376 216 Rp 1½ 11.2 - 12.0
AP35.40.06.A1.V 1 x 220 - 230 V 1.2 0.7 3.9 0.97 6.0 376 216 Rp 1½ 11.2 - 12.0
AP35.40.06.3.V 3 x 200 - 220 V 1.1 0.6 3.2 0.91 6.0 376 216 Rp 1½ 11.1 - 13.4
AP35.40.06.A3.V 3 x 200 - 220 V 1.1 0.6 3.2 0.91 6.0 376 216 Rp 1½ 11.1 - 13.4
AP35.40.06.3.V 3 x 380 - 400 V 1.1 0.7 1.4 0.86 6.0 376 216 Rp 1½ 11.1 - 13.4
AP35.40.06.A3.V 3 x 380 - 400 V 1.1 0.7 1.4 0.86 6.0 376 216 Rp 1½ 11.1 - 13.4
AP35.40.08.1.V 1 x 220 - 230 V 1.3 0.9 5.3 0.98 6.0 410 216 Rp 1½ 12.5 - 13.3
AP35.40.08.A1.V 1 x 220 - 230 V 1.3 0.9 5.3 0.98 6.0 410 216 Rp 1½ 12.5 - 13.3
AP35.40.08.3.V 3 x 200 - 220 V 1.1 0.7 3.6 0.85 4.8 410 216 Rp 1½ 12.1 - 14.4
AP35.40.08.A3.V 3 x 200 - 220 V 1.1 0.7 3.6 0.85 4.8 410 216 Rp 1½ 12.1 - 14.4
AP35.40.08.3.V 3 x 380 - 400 V 1.1 0.7 2.0 0.86 5.2 410 216 Rp 1½ 12.1 - 14.4
AP35.40.08.A3.V 3 x 380 - 400 V 1.1 0.7 2.0 0.86 5.2 410 216 Rp 1½ 12.1 - 14.4
Istart
In---------
Technical data
AP35AP35 installations
TM0
0 5
935
389
8
•
••••
• • •
••
•
• •
•
•
•
• ••
•
•
•
••
•
• ••
•
• ••
••
•
•
•
•
•
•
••
••
••
••
•
•••
• •
••
•
•
•
•
•
•
•
••
••
•
•••
•
••
• •
• •
•••
••
••
•
•
•
••
•
•
•
•
min. ø500
TM0
0 5
936
389
8
•
•
••
••
•
••
••
••
••
••
••
•
••
•
•
•
••
•
••
••
•
•
• ••
•
•• •
•
•
•
•
•
•
•
•
•
•
•
•
•
• ••
••
•
••
••
•
•
••
•
••
•
••
•
• ••
•
•
•
••
•
• ••
•
• ••
•
•
•
•
•
•••
•
•
•
min. ø800
21
22
Technical data
AP35BAP35B
The AP35B pump is a single-stage submersible pumpdesigned for pumping effluent.
The pump is suitable for:
• groundwater lowering,
• pumping in drainage pits,
• pumping in surface water pits with inflow from roof gutters, shafts, tunnels, etc.,
• emptying of ponds, tanks, etc.,
• pumping of fibre-containing effluent from laundries and industries,
• pumping of domestic effluent from septic tanks and sludge treating systems,
• pumping of domestic effluent without discharge from water closets.
Automatic operationThe pump is available for automatic as well as manualoperation and can be installed in a permanent installa-tion or used as a portable pump.
The pump is available:
• with level switch fitted for automatic ON/OFF opera-tion between two liquid levels (single-phase pumps);
• without level switch for manual ON/OFF operation.
Pumps fitted with level switches can also be used formanual ON/OFF operation. In this case the level switchmust be secured in an upwards-pointing position.
Pump housingPump housing with an outstanding design for submers-ible wastewater pumps resulting in a high head.
The pump housing is made of a steel tube with a smoothsurface and a hydraulically correct shape ensuring freepassage of particles.
Base, pump inlet and pump housing are fastened to themotor by means of 4 springs enabling quick and easydismantling.
Discharge portAll AP35B pumps have a threaded horizontal dischargeport: Rp 2.
Shaft and bearingsThe shaft is made of stainless steel and rotates in main-tenance-free prelubricated ball bearings.
ImpellerThe stainless steel impeller is a Vortex impeller withL-shaped blades and a clearance of 35 mm (in the pumphousing). The blades are curved backwards to reduce anyharmful effect from solid particles and to reduce thepower consumption. The impeller has a protective cap toprevent the deposits of long-fibred material.
Shaft sealThe shaft seal is a combination of a mechanical shaftseal of the bellows type and a lip seal with 80 ml oilbetween them. The shaft seal has silicon carbide sealfaces.
Materials
TM0
1 41
87 4
99
8
TM0
0 5
478
400
0
Description Materials DIN
W.-Nr. AISI
Pump housing Stainless steel 1.4301 304
Impeller Stainless steel 1.4301 304
Washer Stainless steel 1.4301 304
Protective cap Novolen 2360 Kx
Motor unit completeParts in contact with liquid:Stainless steel
1.4401 316
Shaft with rotor Stainless steel/silumin 1.4305
Motor cable Neoprene
O-rings NBR rubber
Spring Stainless steel 1.4310
Pump inlet Stainless steel 1.4301 304
Base Polycarbonate
Oil Shell Ondina 15, non-toxic
Technical data
AP35BTM0
1 35
81 4
498
0 5 10 15 20 Q [m³/h]0
2
4
6
8
10
12
14
H[m]
0 1 2 3 4 5 6 Q [l/s]
0
20
40
60
80
100
120
140
p[kPa] AP35B
60 HzISO 9906 Annex A
AP35B.50.06.1AP35B.50.08.1
0 5 10 15 20 Q [m³/h]0.0
0.4
0.8
1.2
1.6
P 1[kW]
0.0
0.5
1.0
1.5
2.0
P 1[hp]
AP35B.50.06.1AP35B.50.08.1
TM0
1 9
219
150
0
D
A
C
S
Pump type VoltageP1
[kW]In
[A]Cos ϕ
Dimensions [mm]Weight
[kg]A C D S
AP35B.50.06.1.V 1 x 220-230 V 1.29 5.91 0.99 3.05 443 116 73 R2 8.5
AP35B.50.06.A1.V 1 x 220-230 V 1.29 5.91 0.99 3.05 443 116 73 R2 8.5
AP35B.50.06.3.V 3 x 200-220 V 1.21 3.71 0.94 4.39 443 116 73 R2 7.5
AP35B.50.08.1.V 1 x 220-230 V 1.47 6.74 0.99 3.59 468 116 73 R2 10.1
AP35B.50.08.A1.V 1 x 220-230 V 1.47 6.74 0.99 3.59 468 116 73 R2 10.1
AP35B.50.08.3.V 3 x 200-220 V 1.48 4.5 0.94 4.87 468 116 73 R2 8.5
Istart
In---------
23
24
Technical data
AP35BAP35B installations
One-pump installation on auto-coupling
Two-pump installation on auto-coupling
TM0
1 35
93
449
8
•
•
••
•
•
•
• •
••
•
••
•
•
••
•
••
•
•••
••
••
••
•
•
•
•
••
•
•
•
•
••
•
•
•
•
••
•
•
•
••
•
•
•
• •
••
•
•
•
•
•
•
•
•
••
•
•••
••
•
• ••
••
•
•
• ••• •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
••
•
•••
••
••
•
••
•
••
•
•
•
•
•
•
•
•
•
•••
•
••
• •
••
•
••
•
•
••
•
•
••
•
•
•
•
•
•
F
C
A
U
Z J
G
K L
N O
T
E
S
TM0
1 35
93
449
8
•
••
•
•
••
•
•
•
••
•
••
••
•
••
•
••
•
•
••
••
•
•
•
•
•
•
•
•
•
• •
••
•
••
•
•
•
•
•
••
••
•
••
•
•
••
•
D
I
M M
R PP
B
Pump typeDimensions [mm]
A B C D E F G I J K L M N O P R S T U Z
AP35B.50.06.1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261
AP35B.50.06.A1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261
AP35B.50.06.3.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261
AP35B.50.08.1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261
AP35B.50.08.A1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261
AP35B.50.08.3.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261
Pump typeDimensions [mm]
A B C D E F G I J K L M N O P R S T U Z
AP35B.50.06.1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261
AP35B.50.06.A1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261
AP35B.50.06.3.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261
AP35B.50.08.1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261
AP35B.50.08.A1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261
AP35B.50.08.3.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261
Technical data
AP50AP50
The AP50 pump is a single-stage submersible pumpdesigned for the pumping of effluent and sewage. Thepump is suitable for the following applications
• ground water lowering,
• pumping in drainage pits,
• pumping in surface water pits with inflow from roof gutters, shafts, tunnels, etc.,
• emptying of ponds, tanks, etc.,
• pumping of fibre-containing wastewater from laun-dries and industries,
• pumping of domestic wastewater from septic tanks and sludge treating systems and
• pumping of domestic wastewater with/without dis-charge from water closets.
ApprovalsPA-I no. 4104 and VDE.
Automatic operationThe pump is available for automatic as well as manualoperation and can be installed in a permanent installa-tion or used as a portable pump. The pump is available:
• with level switch fitted for automatic ON/OFF opera-tion between two liquid levels (single-phase pumps);
• with separate level switch and control box for auto-matic ON/OFF operation between two liquid levels (three-phase pumps);
• without level switch for manual ON/OFF operation
Pumps fitted with level switches can also be used formanual ON/OFF operation. In this case the level switchmust be secured in an upwards-pointing position.
Pump sleeve and housingThe stainless steel pump sleeve is made in one piece andequipped with an insulated carrying handle.
The suction strainer is clipped on to the pump housingand can easily be removed for maintenance. The strainernot only prevents the passage of large solids but alsoensures a slow flow into the pump.
The stainless steel pump housing is fitted with aninternal riser pipe ensuring high efficiency. The riser pipehas a number of holes which enable efficient cooling ofthe motor during operation. The cable entry is of thesocket and plug connection type, which makes quick andeasy dismantling possible.
Discharge portAll AP50 pumps have a threaded vertical discharge port:Rp 2.
Shaft and bearingsThe shaft is made of stainless steel and rotates in main-tenance-free prelubricated ball bearings.
ImpellerThe stainless steel impeller is a Vortex impeller withL-shaped blades and a clearance of 50 mm (in the pumphousing). The blades are curved backwards to reduce anyharmful effect from solid particles and to reduce thepower consumption. The impeller has a protective cap toprevent the deposits of long-fibred material.
Shaft sealThe shaft seal is a combination of a mechanical shaftseal of the bellows type and a lip seal with 60 ml oilbetween them. The shaft seal has silicon carbide sealfaces.
Motor cableStandard pumps 10 m: H07RNF.
Materials
TM0
0 5
740
149
5
TM0
0 5
477
400
0
Description Materials DIN W.-Nr. AISI
Pump housing Stainless steel 1.4301 304
Riser pipe Stainless steel 1.4301 304
Impeller Stainless steel 1.4301 304
Pump sleeve Stainless steel 1.4401 316
Shaft Stainless steel 1.4305
Bearings Heavy-duty prelubricated ball bearings
O-rings NBR rubber
Screws Stainless steel 1.4301 304
Cables Neoprene
Oil Shell Ondina 15, non-toxic
25
26
Performance curves
AP50TM0
0 7
218
419
9
0 4 8 12 16 20 24 28 32 Q [m³/h]
0
1
2
3
4
5
6
7
8
9
10
11
12
13
H[m]
0 2 4 6 8 10 Q [l/s]
0
20
40
60
80
100
120
p[kPa] AP50.50.
60 HzISO 9906 Annex A
08.1.V08.3.V 11.1.V11.3.V
0 4 8 12 16 20 24 28 32 Q [m³/h]
0.0
0.4
0.8
1.2
1.6
2.0
P1[kW]
0.0
0.8
1.6
2.4
P1[hp]
11.V
08.V
TM00
721
8 45
00
Technical data
AP50TM0
0 5
524
09
95
S
B
A
Pump type VoltageP1
[kW]P2
[kW]In
[A]Cos ϕ
Dimensions [mm]Weight
[kg]A B S
AP50.50.08.1.V 1 x 220 - 230 V 1.4 1.0 6.3 0.98 6.0 436 241 Rp 2 14.9 - 15.7
AP50.50.08.A1.V 1 x 220 - 230 V 1.4 1.0 6.3 0.98 6.0 436 241 Rp 2 14.9 - 15.7
AP50.50.08.3.V 3 x 200 - 220 V 1.4 0.9 4.0 0.85 6.0 436 241 Rp 2 14.2 - 16.5
AP50.50.08.A3.V 3 x 200 - 220 V 1.4 0.9 4.0 0.85 6.0 436 241 Rp 2 14.2 - 16.5
AP50.50.08.3.V 3 x 380 - 440 V 1.4 1.0 2.1 0.85 6.0 436 241 Rp 2 14.2 - 16.5
AP50.50.08.A3.V 3 x 380 - 440 V 1.4 1.0 2.1 0.85 6.0 436 241 Rp 2 14.2 - 16.5
AP50.50.11.1.V 1 x 220 - 230 V 1.8 1.2 8.4 0.98 6.0 436 241 Rp 2 14.9 - 15.7
AP50.50.11.A1.V 1 x 220 - 230 V 1.8 1.2 8.4 0.98 6.0 436 241 Rp 2 14.9 - 15.7
AP50.50.11.3.V 3 x 200 - 220 V 1.6 1.2 6.0 0.85 2.9 436 241 Rp 2 15.6 - 17.9
AP50.50.11.A3.V 3 x 200 - 220 V 1.6 1.2 6.0 0.85 2.9 436 241 Rp 2 15.6 - 17.9
AP50.50.11.3.V 3 x 380 - 440 V 1.6 1.6 3.0 0.88 4.9 436 241 Rp 2 15.6 - 17.9
AP50.50.11.A3.V 3 x 380 - 440 V 1.6 1.6 3.0 0.88 4.9 436 241 Rp 2 15.6 - 17.9
Istart
In---------
27
28
Technical data
AP50AP50 installations
TM0
0 5
935
389
8
•
••••
• • •
••
•
• •
•
•
•
• ••
•
•
•
••
•
• ••
•
• ••
••
•
•
•
•
•
•
••
••
••
••
•
•••
• •
••
•
•
•
•
•
•
•
••
••
•
•••
•
••
• •
• •
•••
••
••
•
•
•
••
•
•
•
•
min. ø500
TM0
0 5
936
389
8
•
•
••
••
•
••
••
••
••
••
••
•
••
•
•
•
••
•
••
••
•
•
• ••
•
•• •
•
•
•
•
•
•
•
•
•
•
•
•
•
• ••
••
•
••
••
•
•
••
•
••
•
••
•
• ••
•
•
•
••
•
• ••
•
• ••
•
•
•
•
•
•••
•
•
•
min. ø800
Technical data
AP50BAP50B
The AP50B pump is a single-stage submersible pumpdesigned for the pumping effluent.
The pump is suitable for:
• groundwater lowering,
• pumping in drainage pits,
• pumping in surface water pits with inflow from roof gutters, shafts, tunnels, etc.,
• emptying of ponds, tanks, etc.,
• pumping of fibre-containing effluent from laundries and industries,
• pumping of domestic effluent from septic tanks and sludge treating systems,
• pumping of domestic effluent without discharge from water closets.
Automatic operationThe pump is available for automatic as well as manualoperation and can be installed in a permanent installa-tion or used as a portable pump.
The pump is available:
• with level switch fitted for automatic ON/OFF opera-tion between two liquid levels (single-phase pumps);
• without level switch for manual ON/OFF operation.
Pumps fitted with level switches can also be used formanual ON/OFF operation. In this case the level switchmust be secured in an upwards-pointing position.
Pump housingPump housing with an outstanding design for submers-ible wastewater pumps resulting in a high head.
The pump housing is made of a steel tube with a smoothsurface and a hydraulically correct shape ensuring freepassage of particles.
Base, pump inlet and pump housing are fastened to themotor by means of 4 springs enabling quick and easydismantling.
Discharge portAll AP50B pumps have a threaded horizontal dischargeport: R 2.
Shaft and bearingsThe shaft is made of stainless steel and rotates in main-tenance-free prelubricated ball bearings.
ImpellerThe stainless steel impeller is a Vortex impeller withL-shaped blades and a clearance of 50 mm (in the pumphousing). The blades are curved backwards to reduce anyharmful effect from solid particles and to reduce thepower consumption. The impeller has a protective cap toprevent the deposits of long-fibred material.
Shaft sealThe shaft seal is a combination of a mechanical shaftseal of the bellows type and a lip seal with 80 ml oilbetween them. The shaft seal has silicon carbide sealfaces.
Materials
TM0
1 41
88 4
99
8
TM0
0 5
477
400
0
Description Materials DIN
W.-Nr. AISI
Pump housing Stainless steel 1.4301 304
Impeller Stainless steel 1.4301 304
Washer Stainless steel 1.4301 304
Protective cap Novolen 2360 Kx
Motor unit completeParts in contact with liquid:Stainless steel
1.4305 316
Shaft with rotor Stainless steel/silumin 1.4401
Motor cable Neoprene
O-rings NBR rubber
Spring Stainless steel 1.4310
Pump inlet Stainless steel 1.4301 304
Base Polycarbonate
Oil Shell Ondina 15, non-toxic
29
30
Technical data
AP50BTM0
1 35
83 4
498
0 5 10 15 20 25 Q [m³/h]0
2
4
6
8
10
12
14
16
H[m]
0 1 2 3 4 5 6 7 8 Q [l/s]
0
20
40
60
80
100
120
140
160
p[kPa] AP50B
60 HzISO 9906 Annex A
AP50B.50.08.1
AP50B.50.08.3
A50B.50.11.1
AP50B.50.11.3
AP50B.50.15.3
0 5 10 15 20 25 Q [m³/h]0.0
0.4
0.8
1.2
1.6
2.0
P 1[kW]
0.0
0.5
1.0
1.5
2.0
2.5
P 1[hp]
AP50B.50.08.1
AP50B.50.08.3
AP50B.50.11.1
AP50B.50.11.3
AP50B.50.15.3
TM
01 3
583
3100
TM0
1 9
219
150
0
D
A
C
S
Pump type VoltageP1
[kW]P2
[kW]In
[A]Cos ϕ
Dimensions [mm]Weight
[kg]A C D S
AP50B.50.08.1.V 1 x 220-230 V 1.4 0.8 6.4 0.99 3.78 468 116 73 R2 10.1
AP50B.50.08.A1.V 1 x 220-230 V 1.4 0.8 6.4 0.99 3.78 468 116 73 R2 10.1
AP50B.50.08.3.V 3 x 200-220 V 1.31 0.8 4.12 0.92 5.32 468 116 73 R2 8.5
AP50B.50.11.1.V 1 x 220-230 V 1.8 1.1 8.42 0.97 3.56 468 116 73 R2 10.1
AP50B.50.11.A1.V 1 x 220-230 V 1.8 1.1 8.42 0.97 3.56 468 116 73 R2 10.1
AP50B.50.11.3.V 3 x 200-220 V 1.73 1.1 5.41 0.93 5.91 468 116 73 R2 9.8
AP50B.50.15.3.V 3 x 200-220 V 1.98 1.5 6.25 0.91 6.4 468 116 73 R2 10.0
Istart
In---------
Technical data
AP50BAP50B installations
One-pump installation on auto-coupling
Two-pump installation on auto-coupling
TM0
1 35
93
449
8
•
•
••
•
•
•
• •
••
•
••
•
•
••
•
••
•
•••
••
••
••
•
•
•
•
••
•
•
•
•
••
•
•
•
•
••
•
•
•
••
•
•
•
• •
••
•
•
•
•
•
•
•
•
••
•
•••
••
•
• ••
••
•
•
• ••• •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
••
•
•••
••
••
•
••
•
••
•
•
•
•
•
•
•
•
•
•••
•
••
• •
••
•
••
•
•
••
•
•
••
•
•
•
•
•
•
F
C
A
U
Z J
G
K L
N O
T
E
S
TM0
1 35
93
449
8
•
••
•
•
••
•
•
•
••
•
••
••
•
••
•
••
•
•
••
••
•
•
•
•
•
•
•
•
•
• •
••
•
••
•
•
•
•
•
••
••
•
••
•
•
••
•
D
I
M M
R PP
B
Pump typeDimensions [mm]
A B C D E F G I J K L M N O P R S T U Z
AP50B.50.08.1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261
AP50B.50.08.A1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261
AP50B.50.08.3.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261
AP50B.50.11.1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261
AP50B.50.11.A1.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261
AP50B.50.11.3.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261
AP50B.50.15.3.V ø600 ø600 304 135 82 85 65 100 76 150 400 200 300 700 500 - R 2 ¾" 130 261
Pump typeDimensions [mm]
A B C D E F G I J K L M N O P R S T U Z
AP50B.50.08.1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261
AP50B.50.08.A1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261
AP50B.50.08.3.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261
AP50B.50.11.1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261
AP50B.50.11.A1.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261
AP50B.50.11.3.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261
AP50B.50.15.3.V 600 600 304 135 82 85 26 100 76 150 400 200 300 700 335 330 R 2 ¾" 130 261
31
32
Technical data
AP51AP51 with single-channel impeller
The pumps are used for pumping wastewater, sludge-containing water, considerable quantities of surfacewater and ground water in places such as
• holiday homes,
• public buildings,
• factories,
• garages,
• underground car parks and
• car wash areas.
If permitted by local laws or regulations, the AP51 pumpscan be used for the pumping of sewage from single andmulti-family houses.
Pump and stator housingThe pump housing and the stator housing are made ofcast iron.
The stator housing is dry, i.e. not oil-filled.
DischargeAll AP51 pumps have a horizontal R 2½ discharge port forthreaded connection.
Shaft and bearingsThe shaft is made of stainless steel and rotates in main-tenance-free prelubricated ball bearings.
The lower bearing of AP51.65.22, AP51.65.23, AP51.65.34and AP51.65.35 comprises a double row of ball bearings.
ImpellerThe impeller is a closed single-channel cast iron impellerwith a clearance of 51 mm. Cast iron is chosen as it isresistant towards mechanically wearing particles.
The inlet side of the pump housing is fitted with areplaceable neck ring.
Shaft sealAP51.65.22 to Combination of mechanicalAP51.65.35 bellows seal and lip seal.
The primary shaft seal has siliconcarbide/silicon carbide seal faces.The secondary shaft seal is a lipseal. The chamber between theshaft seals is filled with 0.01 litre ofoil.
AP51.65.22 to Two mechanical bellows seals,AP51.65.35 with silicon carbide/silicon carbide
seal faces. The chamber betweenthe primary and the secondaryshaft seals is filled with 1.2 litre ofoil.
Motor cableStandard pumps 10 m: H07RNF.
Materials
Control boxFurther information about control box, float switch, andlevel controller, see page 40.
TM0
1 71
74 4
09
9
TM0
0 3
566
50
93
Description Materials DIN W.-Nr. AISI
Stator housing Cast iron GG 25 0.6025 ASTM 35B
Pump housing Cast iron GG 25 0.6025 ASTM 35B
Neck ring Bronze
Impeller Cast iron GG 25 0.6025 ASTM 35B
Shaft Stainless steel 1.4104 AISI 430F
Bearings Heavy-duty prelubricated ball bearings
Screws Stainless steel 1.4301 AISI 304
Oil Shell Ondina 15, non-toxic
Performance curves
AP51TM0
0 6
774
479
9
0 10 20 30 40 50 60 70 Q [m³/h]
0
1
2
3
4
[kW]P1
0
2
4
P1[hp]
34.3 35.3
23.3
22.315.3
14.313.1
09.309.1
0 10 20 30 40 50 60 70 Q [m³/h]
0
4
8
12
16
20
24
28
[m]H
0 5 10 15 20 Q [l/s]
0
80
160
240
p [kPa] AP51.65.
60 HzISO 2548 Annex B
34.3
35.3
23.3
22.3
15.3
14.3
13.1
09.3
09.1
33
34
Technical data
AP51Elbow is an accessory.
TM0
1 25
64
209
8
S
E
C
D
B
A
Pump type VoltageP1
[kW]P2
[kW]n
[min-1]In
[A]Cos ϕ
Dimensions [mm]Weight
[kg]A B C D E S
AP51.65.09.1 1 x 230 V 1.2 0.9 3450 5.4 0.97 6.0 465 350 124 65 198 R 2½ 27 - 28
AP51.65.09.A1 1 x 230 V 1.2 0.9 3450 5.4 0.97 6.0 465 350 124 65 198 R 2½ 27 - 28
AP51.65.09.3 3 x 230 V 1.2 0.9 3450 4.0 0.79 6.0 465 350 124 65 198 R 2½ 26
AP51.65.09.3 3 x 380 V 1.2 0.9 3450 2.3 0.79 6.0 465 350 124 65 198 R 2½ 26
AP51.65.09.3 3 x 460 V 1.2 0.9 3450 1.9 0.79 6.0 465 350 124 65 198 R 2½ 26
AP51.65.13.1 1 x 230 V 1.8 1.3 3450 7.8 0.97 6.0 465 350 124 65 198 R 2½ 28 - 29
AP51.65.13.A1 1 x 230 V 1.8 1.3 3450 7.8 0.97 6.0 465 350 124 65 198 R 2½ 28 - 29
AP51.65.14.3 3 x 230 V 1.8 1.4 3450 5.6 0.83 6.0 465 350 124 65 198 R 2½ 27
AP51.65.14.3 3 x 380 V 1.8 1.4 3450 3.3 0.83 6.0 465 350 124 65 198 R 2½ 27
AP51.65.14.3 3 x 460 V 1.8 1.4 3450 2.7 0.83 6.0 465 350 124 65 198 R 2½ 27
AP51.65.15.3 3 x 230 V 1.8 1.4 3450 5.6 0.84 6.0 465 350 124 65 198 R 2½ 27
AP51.65.15.3 3 x 380 V 1.8 1.4 3450 3.3 0.84 6.0 465 350 124 65 198 R 2½ 27
AP51.65.15.3 3 x 460 V 1.8 1.4 3450 2.7 0.84 6.0 465 350 124 65 198 R 2½ 27
AP51.65.22.3 3 x 230 V 2.8 2.2 3450 8.4 0.88 6.0 518 368 101 50 185 R 2½ 45
AP51.65.22.3 3 x 380 V 2.8 2.2 3450 4.8 0.88 6.0 518 368 101 50 185 R 2½ 45
AP51.65.22.3 3 x 460 V 2.8 2.2 3450 4.0 0.88 6.0 518 368 101 50 185 R 2½ 45
AP51.65.23.3 3 x 230 V 2.8 2.3 3450 8.4 0.88 6.0 518 368 101 50 185 R 2½ 45
AP51.65.23.3 3 x 380 V 2.8 2.3 3450 4.8 0.88 6.0 518 368 101 50 185 R 2½ 45
AP51.65.23.3 3 x 460 V 2.8 2.3 3450 4.0 0.88 6.0 518 368 101 50 185 R 2½ 45
AP51.65.34.3 3 x 230 V 4.0 3.4 3450 12.5 0.84 6.0 518 368 101 50 185 R 2½ 45
AP51.65.34.3 3 x 380 V 4.0 3.4 3450 6.7 0.84 6.0 518 368 101 50 185 R 2½ 45
AP51.65.34.3 3 x 460 V 4.0 3.4 3450 6.0 0.84 6.0 518 368 101 50 185 R 2½ 45
AP51.65.35.3 3 x 230 V 4.0 3.5 3450 12.5 0.84 6.0 518 368 101 50 185 R 2½ 45
AP51.65.35.3 3 x 380 V 4.0 3.5 3450 6.7 0.84 6.0 518 368 101 50 185 R 2½ 45
AP51.65.35.3 3 x 380 V 4.0 3.5 3450 6.0 0.84 6.0 518 368 101 50 185 R 2½ 45
Istart
In---------
Technical data
AP51AP51 installations
One-pump installation on auto-coupling
Two-pump installation on auto-coupling
TM0
1 25
65
209
8
‹
‹‹
‹
‹
‹
‹ ‹
‹
‹
‹ ‹‹
‹‹
‹
‹
‹‹
‹
‹
‹
‹
‹‹
‹‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹‹
‹
‹
‹‹
‹
‹
‹
‹
‹
‹
‹‹
‹
‹
‹
‹
‹
‹
‹ ‹‹
‹‹
‹
‹‹
‹‹‹‹
‹
‹
‹
‹
‹
‹‹
‹‹
‹‹
‹
‹
‹
‹
‹
‹‹
‹
‹‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹‹
‹‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹‹
‹
‹
‹‹
‹
‹
‹
‹
‹‹
‹
‹
‹
‹‹‹
‹
‹‹
‹ ‹
‹‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹ ‹
‹‹‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹ ‹‹
‹‹
‹
‹ ‹‹
‹ ‹
‹
‹
‹
‹
‹
‹
K
G
H
L
N O
F
C
A
U
V
J
S
TM0
1 25
66
20
98
‹‹
‹
‹
‹
‹
‹
‹‹
‹‹
‹
‹
‹‹
‹
‹
‹
‹
‹‹
‹‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹ ‹
‹ ‹‹
‹
‹
‹
‹
‹
‹
‹
‹‹
‹‹
‹
‹
‹
‹
‹
‹
‹
‹‹
‹
‹ ‹
‹
‹
‹
‹
‹
‹
‹
‹ ‹
‹
‹
‹
‹
‹
‹
RP P
MM
I
B
D
Pump type A B C D E F G H I J K L M N O P S T U V
AP51.65.09.1 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.09.A1 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.09.3 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.13.1 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.13.A1 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.14.3 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.15.3 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.22.3 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.23.3 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.34.3 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.35.3 ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
Pump type A B C D E F G H I J K L M N O P R S T U V
AP51.65.09.1 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.09.A1 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.09.3 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.13.1 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.13.A1 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.14.3 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.15.3 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.22.3 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.23.3 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.34.3 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.35.3 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
35
36
Technical data
AP51 VortexAP51 with Vortex impeller
The pumps are used for pumping wastewater, sludge-containing water, considerable quantities of surfacewater and ground water in places such as
• holiday homes,
• public buildings,
• factories,
• garages,
• underground car parks and
• car wash areas.
If permitted by local laws or regulations, the AP51 Vortexpumps can be used for the pumping of sewage fromsingle and multi-family houses.
Pump and stator housingThe pump housing and the stator housing are made ofcast iron.
The stator housing of AP51.65.14V and AP51.65.15V is dry,i.e. not oil-filled.
The stator housing of AP51.65.23V, AP51.65.34V,AP51.65.35V and AP51.65.36V is oil-filled.
All AP51 pumps are fitted with casted legs for free-standing installation.
DischargeAll AP51 pumps have a horizontal R 2½ discharge port forthreaded connection.
Shaft and bearingsThe shaft is made of chromium steel and rotates inmaintenance-free prelubricated ball bearings.
The lower bearing of AP51.65.23V, AP51.65.34V andAP51.65.36V comprises a double row of ball bearings.
All AP51 pumps are fitted with casted legs for free-standing installation.
ImpellerThe impeller is a vortex impeller in cast iron GG 25 witha free passage of 51 mm in the pump housing. Cast ironis chosen as it is resistant towards mechanically wearingparticles.
Shaft sealAP51.65.14, Combination of mechanical bellows AP51.65.15: seal and lip seal. The primary shaft
seal is made of silicon carbide/siliconcarbide. The secondary shaft seal is alip seal. The chamber between theshaft seals is oil-filled.
AP51.65.23, Two mechanical bellows seals and a AP51.65.34, lip seal. AP51.65.35, The primary and the secondary shaft AP51.65.36: seals are made of silicon carbide/
silicon carbide. The chamber betweenthe primary and the secondary shaftseals is oil-filled. Between the lowerball bearing and the stator housingthere is a lip seal.
Motor cableStandard pumps 10 m: H07RNF.
Materials
Control boxFurther information about control box, float switch, andlevel controller, see page 40.
TM0
1 71
74 4
09
9
TM0
1 26
17 2
09
8
Description Materials DIN W.-Nr. AISI
Stator housing Cast iron GG 25 0.6025 ASTM 35B
Pump housing Cast iron GG 25 0.6025 ASTM 35B
Neck ring Bronze
Impeller Cast iron GG 25 0.6025 ASTM 35B
Shaft Stainless steel 1.4104 AISI 430F
Bearings Heavy-duty prelubricated ball bearings
Screws Stainless steel 1.4301 AISI 304
Oil Shell Ondina 15, non-toxic
Performance curves
AP51 VortexTM0
0 6
776
479
9
0 5 10 15 20 25 30 35 40 45 Q [m³/h]0.00.51.01.52.02.53.03.54.0
[kW]P 1
0
1
2
3
4
5
P 1[hp]
AP51.65.36.3.VAP51.65.35.3.V AP51.65.34.3.V
AP51.65.23.3.V
AP51.65.15.3.VAP51.65.14.3.V AP51.65.14.1.V
0 5 10 15 20 25 30 35 40 45 Q [m³/h]0
2
4
6
8
10
12
14
16
18
20
22
24
[m]H
0 1 2 3 4 5 6 7 8 9 10 11 12 13 Q [l/s]
0
20
40
60
80
100
120
140
160
180
200
220
240
p [kPa]
AP5160 Hz
ISO 2548 Annex B
AP51.65.36.3.V
AP51.65.35.3.VAP51.65.34.3.V
AP51.65.23.3.VAP51.65.15.3.VAP51.65.14.3.VAP51.65.14.1.V
37
38
Technical data
AP51 VortexElbow is an accessory.
TM0
1 25
64
209
8
S
E
C
D
B
A
Pump type VoltageP1
[kW]P2
[kW]n
[min-1]In
[A]Cos ϕ
Dimensions [mm]Weight
[kg]A B C D E S
AP51.65.14.1.V 1 x 230 V 1.8 1.4 3450 8.0 0.99 6.0 465 350 124 65 198 R 2½ 27
AP51.65.14.A1.V 1 x 230 V 1.8 1.4 3450 8.0 0.99 6.0 465 350 124 65 198 R 2½ 27
AP51.65.14.3.V 3 x 230 V 1.8 1.4 3450 5.6 0.84 6.0 465 350 124 65 198 R 2½ 27
AP51.65.14.3.V 3 x 380 V 1.8 1.4 3450 3.3 0.84 6.0 465 350 124 65 198 R 2½ 27
AP51.65.14.3.V 3 x 460 V 1.8 1.4 3450 2.7 0.84 6.0 465 350 124 65 198 R 2½ 27
AP51.65.15.3.V 3 x 230 V 1.8 1.4 1750 5.4 0.70 6.0 518 368 101 50 187 R 2½ 27
AP51.65.15.3.V 3 x 380 V 1.8 1.4 1750 3.2 0.70 6.0 518 368 101 50 187 R 2½ 27
AP51.65.15.3.V 3 x 460 V 1.8 1.4 1750 2.6 0.70 6.0 518 368 101 50 187 R 2½ 27
AP51.65.23.3.V 3 x 230 V 2.8 2.3 3450 8.4 0.88 6.0 518 368 101 50 185 R 2½ 40
AP51.65.23.3.V 3 x 380 V 2.8 2.3 3450 4.8 0.88 6.0 518 368 101 50 185 R 2½ 40
AP51.65.23.3.V 3 x 460 V 2.8 2.3 3450 4.0 0.88 6.0 518 368 101 50 185 R 2½ 40
AP51.65.34.3.V 3 x 230 V 4.0 3.4 3450 12.5 0.84 6.0 555 368 101 50 185 R 2½ 45
AP51.65.34.3.V 3 x 380 V 4.0 3.4 3450 6.7 0.84 6.0 555 368 101 50 185 R 2½ 45
AP51.65.34.3.V 3 x 460 V 4.0 3.4 3450 6.0 0.84 6.0 555 368 101 50 185 R 2½ 45
AP51.65.35.3.V 3 x 230 V 4.0 3.5 3450 12.5 0.84 6.0 555 368 101 50 185 R 2½ 45
AP51.65.35.3.V 3 x 380 V 4.0 3.5 3450 6.7 0.84 6.0 555 368 101 50 185 R 2½ 45
AP51.65.35.3.V 3 x 460 V 4.0 3.5 3450 6.0 0.84 6.0 555 368 101 50 185 R 2½ 45
AP51.65.36.3.V 3 x 230 V 4.0 3.6 3450 12.5 0.84 6.0 555 368 101 50 185 R 2½ 45
AP51.65.36.3.V 3 x 380 V 4.0 3.6 3450 6.7 0.84 6.0 555 368 101 50 185 R 2½ 45
AP51.65.36.3.V 3 x 460 V 4.0 3.6 3450 6.0 0.84 6.0 555 368 101 50 185 R 2½ 45
Istart
In---------
Technical data
AP51 VortexAP51 installations
One-pump installation on auto-coupling
Two-pump installation on auto-coupling
TM0
1 25
65
209
8
‹
‹‹
‹
‹
‹
‹ ‹
‹
‹
‹ ‹‹
‹‹
‹
‹
‹‹
‹
‹
‹
‹
‹‹
‹‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹‹
‹
‹
‹‹
‹
‹
‹
‹
‹
‹
‹‹
‹
‹
‹
‹
‹
‹
‹ ‹‹
‹‹
‹
‹‹
‹‹‹‹
‹
‹
‹
‹
‹
‹‹
‹‹
‹‹
‹
‹
‹
‹
‹
‹‹
‹
‹‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹‹
‹‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹‹
‹
‹
‹‹
‹
‹
‹
‹
‹‹
‹
‹
‹
‹‹‹
‹
‹‹
‹ ‹
‹‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹ ‹
‹‹‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹ ‹‹
‹‹
‹
‹ ‹‹
‹ ‹
‹
‹
‹
‹
‹
‹
K
G
H
L
N O
F
C
A
U
V
J
S
TM0
1 25
66
20
98
‹‹
‹
‹
‹
‹
‹
‹‹
‹‹
‹
‹
‹‹
‹
‹
‹
‹
‹‹
‹‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹
‹ ‹
‹ ‹‹
‹
‹
‹
‹
‹
‹
‹
‹‹
‹‹
‹
‹
‹
‹
‹
‹
‹
‹‹
‹
‹ ‹
‹
‹
‹
‹
‹
‹
‹
‹ ‹
‹
‹
‹
‹
‹
‹
RP P
MM
I
B
D
Pump type A B C D E F G H I J K L M N O P S T U V
AP51.65.14.1.V ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.14.A1.V ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.14.3.V ø600 ø600 284 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.15.3.V ø600 ø600 300 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.23.3.V ø600 ø600 300 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.34.3.V ø600 ø600 300 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.35.3.V ø600 ø600 300 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
AP51.65.36.3.V ø600 ø600 300 300 70 60 82 68 180 85 150 410 220 350 650 500 DN 65 1" 140 240
Pump type A B C D E F G H I J K L M N O P R S T U V
AP51.65.14.1.V 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.14.A1.V 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.14.3.V 600 975 284 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.15.3.V 600 975 300 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.23.3.V 600 975 300 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.34.3.V 600 975 300 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.35.3.V 600 975 300 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
AP51.65.36.3.V 600 975 300 297 70 60 82 68 180 85 150 410 220 375 875 435 380 DN 65 1" 140 240
39
40
Technical data Control box
Control box
Variants
The AP pump range comprises versions with or withoutcontrol box and float switch, versions designed forsingle-phase or three-phase power supply versions.
All types are designed for voltage tolerances of ±10%.
Pumps with control box and float switch
Some AP pumps can be supplied with a float switch forautomatic start/stop of the pump. The float switch cableshould be fastened to the retainer on the pump handle.
The difference in level between start and stop may beadjusted by adjusting the free length of cable betweenthe float switch and the retainer.Large difference in level: Long cable.Small difference in level: Short cable.The float switch is connected directly to the control boxthrough a 10 metres long cable.
The mains cable between the pump and the control boxis 10 metres long. The mains cable of the control box isan 0.8 metres long free cable end.
The control box includes a motor starter, and for single-phase pumps also an operating capacitor. The pumpsrequire no further motor protection.
An alarm signal can be given in case of a too high levelby means of a separate float switch connected to analarm. The high-level alarm switch and the alarm areavailable as accessories.
Further information about control boxes for a specificpump type, see "Product range", page 49.
Pumps with control box without float switch for manual on/off operation
The mains cable between the pump and the control- boxis 10 metres long. The mains cable of the control box isan 0.8 metres long free cable end.
The control box includes a motor starter and an oper-ating capacitor but no relays for float switch.
Pumps without control box.
Pumps without control box must be connected to aseparate motor starter. The motor starter is available asan accessory.
Single-phase pumps must also be connected to a capac-itor.
Level controller
A level controller and switches are available as optionalextras for the control, monitoring and protection ofthree-phase 60 Hz AP pumps. Level controller LC isdesigned for one-pump operation, and LCD for two-pump operation.
The level controller incorporates motor starter, contac-tors and light-emitting diodes (LC/LCD) for indication ofoperating condition.
Pump with control box and float switch.
Pumps with control box without float switch for manualon/off operation.
Two pumps with level controller LCD.
TM0
0 6
671
229
8TM
00
66
70 2
298
TM0
0 6
672
080
0
CU 212 2112
Technical data
AP80AP80The pumps are used for pumping sewage, wastewater,considerable quantities of surface water and groundwater in places such as
• municipal pump pits,
• public buildings,
• block of flats,
• factories and
• underground car-parks.
Pump and stator housingThe pump housing and the stator housing are made ofcast iron.
The stator housing is dry, i.e. not oil-filled.
DischargeAll AP80 pumps have a horizontal discharge port with aDN 100 DIN flange.
Shaft and bearingsThe shaft is made of stainless steel and rotates in main-tenance-free prelubricated ball bearings.The lower bearing is a double-row ball bearing.
ImpellerThe impeller is a single-channel cast iron impeller with aclearance of 80 mm. Cast iron is chosen as it is resistanttowards mechanically wearing particles.
The inlet side of the pump housing is fitted with areplaceable neck ring.
Level controllerFurther information about level controller, see page 40.
Shaft sealTwo mechanical bellows seals with silicon carbide/silicon carbide seal faces.
The chamber between the primary and the secondaryshaft seal is filled with
• AP80.100.15-65 1.7 litres
• AP80.100.74-107 3.0 litres
InstallationAll AP80 pumps are fitted with motors for direct-on-linestarting. AP80 pumps with motors for star-delta startingare available on request.
Motor cableStandard pumps 10 m: H07RNF
Materials
Cooling jacketOn request all AP80 pumps can be supplied with a stain-less steel cooling jacket.
Liquid temperature with cooling jacket: 0°C to +40°C.For short periods, max. one hour: Up to +60°C. Forperiods longer than one hour, external cooling isrequired.
The cooling jacket is available for internal as well asexternal cooling of the motor in both dry and submergedinstallations.
Internal cooling (standard) is achieved by leading part ofthe pumped liquid around the stator housing and backto the pump housing via internal channels.
For external cooling the cooling jacket is fitted withsockets for pipe connections.
The cooling jacket is required for cooling of the motor indry installations, and in submerged installations if thepump is not completely submerged during continuousoperation.
TM0
0 5
488
089
5
Description Materials DIN W.-Nr. AISI/ASTM
Stator housing Cast iron GG 25 0.6025 ASTM 35B
Pump housing Cast iron GG 25 0.6025 ASTM 35B
Neck ring Bronze
Impeller Cast iron GG 25 0.6025 ASTM 35B
Shaft Stainless steel 1.4104 AISI 430F
Bearings Heavy-duty prelubricated ball bearings
Screws Stainless steel 1.4301 AISI 304
Cooling jacket Stainless steel 1.4301 AISI 304
Oil Shell Ondina 15, non-toxic
41
42
Performance curves
AP80TM0
1 36
37 4
498
0 20 40 60 80 100 120 140 160 180 200 Q [m³/h]
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
H[m]
0 5 10 15 20 25 30 35 40 45 50 55 60 Q [l/s]
0
20
40
60
80
100
120
140
160
180
200
220
240
260
280
p[kPa] AP80.100
60 HzISO 2548 Annex B
AP80.100.15
AP80.100.21
AP80.100.27
AP80.100.35
AP80.100.47
AP80.100.65
AP80.100.74
AP80.100.87
AP80.100.107
0 20 40 60 80 100 120 140 160 180 200 Q [m³/h]
0
2
4
6
8
10
12
P1[kW]
0
2
4
6
8
10
12
14
16
P1[hp]
107
87
74
65
47
35
2721
15
Technical data
AP80DN 100/DN 100
DN 150/DN 100
TM0
1 42
54 5
09
8TM
01
470
1 0
799
DN100
DN100
ø15
X
W
200
1 1/2"
8760
415
240
240
2020
270
200
G
HV
U
Y
AP80.100.15-74
W
X
110100
2"
280
V
U
27545
0
2020
300
400
340
Y
H
G
ø15
DN100
DN150
AP80.100.15-74
TM0
1 42
58 5
09
8TM
01
470
2 0
799
DN100
DN100
ø15
X
W
200
1 1/2"
8760
415
240
240
2020
270
200
V
Y
H
GU
AP80.100.87-107
W
X
110100
2"
280
27545
0
2020
300
400
340
ø15
DN100
DN150
V
U
H
G
Y
AP80.100.87-107
43
44
Technical data
AP80Submerged free-standing installation
TM0
1 42
55 5
09
8
AP80.100.15-74
J
G
H
ø395 125
DN100
DN100
120
A
B
D
C
F
E
TM0
1 42
59 5
09
8
ø395 125
DN100
DN100
120
A
B
C
F
E
D
J
G
H
AP80.100.87-107
Technical data
AP80Dimensions for installation on auto-coupling DN 100
Dimensions for installation on auto-coupling DN 150
Dimensions for submerged free-standing installation
Pump typeDimensions [mm]
V W U G H X Y
AP80.100.15 147 347 852 307 147 589 767
AP80.100.21 147 347 852 307 147 589 767
AP80.100.27 147 347 852 307 147 589 767
AP80.100.35 147 347 852 307 147 589 767
AP80.100.47 147 347 922 307 147 589 767
AP80.100.65 122 377 927 363 165 643 871
AP80.100.74 122 377 927 363 165 643 871
AP80.100.87 122 377 1023 363 165 643 871
AP80.100.107 122 377 1083 363 165 643 871
Pump typeDimensions [mm]
V W U G H X Y
AP80.100.15 156 425 961 307 147 714 1027
AP80.100.21 156 425 961 307 147 714 1027
AP80.100.27 156 425 961 307 147 714 1027
AP80.100.35 156 425 961 307 147 714 1027
AP80.100.47 156 425 961 307 147 714 1027
AP80.100.65 156 425 961 363 165 714 1027
AP80.100.74 156 425 961 363 165 714 1027
AP80.100.87 156 425 1207 363 165 714 1027
AP80.100.107 156 425 1207 363 165 714 1027
Pump typeDimensions [mm]
A B D E F G H
AP80.100.15 705 830 218 355 200 307 147
AP80.100.21 705 830 218 355 200 307 147
AP80.100.27 705 830 218 355 200 307 147
AP80.100.35 705 830 218 355 200 307 147
AP80.100.47 775 900 218 355 200 307 147
AP80.100.65 805 930 244 459 280 363 165
AP80.100.74 805 930 244 459 280 363 165
AP80.100.87 901 1026 244 459 280 363 165
AP80.100.107 961 1086 244 459 280 363 165
45
46
Technical data
AP80Electrical data and weights
Pump type VoltageP1
[kW]P2
[kW]n
[min-1]In
[A]Cos ϕ Weights
[kg]
AP80.100.15 3 x 230 V 1.7 1.5 1750 6.2 0.87 1.3 95
AP80.100.15 3 x 380 V 1.7 1.5 1750 3.8 0.87 1.3 95
AP80.100.15 3 x 440 V 1.7 1.5 1750 3.2 0.87 1.3 95
AP80.100.15 3 x 460 V 1.7 1.5 1750 3.1 0.87 1.3 95
AP80.100.21 3 x 230 V 2.6 2.1 1750 7.8 0.87 4.0 95
AP80.100.21 3 x 380 V 2.6 2.1 1750 4.7 0.87 4.0 95
AP80.100.21 3 x 440 V 2.6 2.1 1750 4.1 0.87 4.0 95
AP80.100.21 3 x 460 V 2.6 2.1 1750 3.9 0.87 4.0 95
AP80.100.27 3 x 230 V 3.2 2.7 1750 9.2 0.86 6.0 99
AP80.100.27 3 x 380 V 3.2 2.7 1750 5.6 0.86 6.0 99
AP80.100.27 3 x 440 V 3.2 2.7 1750 4.8 0.86 6.0 99
AP80.100.27 3 x 460 V 3.2 2.7 1750 4.6 0.86 6.0 99
AP80.100.35 3 x 230 V 4.1 3.5 1750 12.0 0.87 5.0 100
AP80.100.35 3 x 380 V 4.1 3.5 1750 7.3 0.87 5.0 100
AP80.100.35 3 x 440 V 4.1 3.5 1750 6.3 0.87 5.0 100
AP80.100.35 3 x 460 V 4.1 3.5 1750 6.0 0.87 5.0 100
AP80.100.47 3 x 230 V 5.5 4.7 1750 16.0 0.87 5.5 124
AP80.100.47 3 x 380 V 5.5 4.7 1750 9.7 0.87 5.5 124
AP80.100.47 3 x 440 V 5.5 4.7 1750 8.4 0.87 5.5 124
AP80.100.47 3 x 460 V 5.5 4.7 1750 8.0 0.87 5.5 124
AP80.100.65 3 x 230 V 7.5 6.5 1750 22.0 0.87 5.0 126
AP80.100.65 3 x 380 V 7.5 6.5 1750 13.3 0.87 5.0 126
AP80.100.65 3 x 440 V 7.5 6.5 1750 11.5 0.87 5.0 126
AP80.100.65 3 x 460 V 7.5 6.5 1750 11.0 0.87 5.0 126
AP80.100.74 3 x 230 V 8.5 7.4 1750 24.6 0.87 5.0 126
AP80.100.74 3 x 380 V 8.5 7.4 1750 14.9 0.87 5.0 126
AP80.100.74 3 x 440 V 8.5 7.4 1750 12.9 0.87 5.0 126
AP80.100.74 3 x 460 V 8.5 7.4 1750 12.3 0.87 5.0 126
AP80.100.87 3 x 230 V 10.7 8.7 1750 29.0 0.88 5.0 196
AP80.100.87 3 x 380 V 10.7 8.7 1750 17.6 0.88 5.0 196
AP80.100.87 3 x 440 V 10.7 8.7 1750 16.0 0.88 5.0 196
AP80.100.87 3 x 460 V 10.7 8.7 1750 14.5 0.88 5.0 196
AP80.100.107 3 x 230 V 12.3 10.7 1750 37.0 0.82 7.0 223
AP80.100.107 3 x 380 V 12.3 10.7 1750 22.4 0.82 7.0 223
AP80.100.107 3 x 440 V 12.3 10.7 1750 19.3 0.82 7.0 223
AP80.100.107 3 x 460 V 12.3 10.7 1750 18.5 0.82 7.0 223
Istart
In---------
Technical data
APGAPG pumps
APG pumps are specifically designed for the pumping ofsewage from small villages and farms, and in areas ofdifficult topography, e.g. rocky terrain with large differ-ences in level.
A cutter system at the impeller inlet cuts destructiblesolids into small pieces so that the sewage can be ledaway through pipes of a relatively small diameter.
Due to the pressurized pumping system, the APG pumpsare especially efficient in areas where traditional gravitypumping systems cannot be used.
ApprovalsPA-I no. 3986.
Pump and stator housingThe pump housing and the stator housing are made ofcast iron.
The stator housing is dry, i.e. not oil-filled.
DischargeAll APG pumps have an externally threaded dischargeport: R 2.
Impeller and cutter systemThe impeller is a semi-open multivane cast iron im-peller.
The cutter system consists of a stationary ring with fourcutting edges and a rotating cutting head at the end ofthe pump shaft. The cutter system is made ofspecial,hardened high-alloy steel.
An adjustable cast iron wear plate is fitted at the inletside of the impeller.
Shaft and bearingsThe shaft is made of stainless steel and rotates in main-tenance-free prelubricated ball bearings.
The lower bearing comprises a double row of ball bear-ings.
Shaft seals
APG.50.11 - 12:
Combination of mechanical shaft seal and lip seal.
The primary shaft seal has silicon carbide/silicon carbideseal faces. The secondary shaft seal is a lip seal. Thechamber between the shaft seals is filled with 0.7 litre ofoil.
APG.50.18 - 33:
Two mechanical bellows seals.
The primary and the secondary shaft seals have siliconcarbide/silicon carbide seal faces. The chamber betweenthe primary and the secondary shaft seals is filled with1.2 litres of oil.
Motor cableStandard pumps 10 m: H07RNF.
Materials
TM0
1 71
82 4
09
9
TM0
0 3
576
519
3
Description Material DIN W.-Nr.AISI/ASTM
Stator housing Cast iron GG 25 0.6025 ASTM 35.B
Pump housing Cast iron GG 25 0.6025 ASTM 35.B
Wear plate Cast iron GG 25 0.6025 ASTM 35.B
Impeller Cast iron GG 25 0.6025 ASTM 35.B
Shaft Stainless steel 1.4104 AISI 430 F
Cutter system Hardened steel
Bearings Heavy-duty prelubricated ball bearings
Screws Stainless steel 1.4301 AISI 304
Oil Shell Ondina 15, non-toxic
47
48
Performance curves
APGTM0
0 7
216
159
9
0 2 4 6 8 10 12 14 16 18 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50
H[m]
0 1 2 3 4 5 Q [l/s]
0
100
200
300
400
500
p[kPa] APG
60 HzISO 2548 Annex B
APG.50.33.1APG.50.29.3APG.50.30.1
APG.50.18.1APG.50.19.3APG.50.11.3APG.50.12.1
0 2 4 6 8 10 12 14 16 18 Q [m³/h]
0
1
2
3
4
P1[kW]
0
2
4
6
P1[hp]
APG.50.33.1
APG.50.29.3
APG.50.30.1
APG.50.19.3 APG.50.18.1
APG.50.11.3
APG.50.12.1
Technical data
APGElbow and ring stand are accessories.
TM0
1 26
03
209
8
B
D C
E
A
S
Pump type VoltageP1
[kW]P2
[kW]n
[min]In
[A]Cos ϕ
Dimensions [mm]Weight *
[kg]A B C D E S
APG.50.11.3 3 x 230 V 1.5 1.1 3450 6.2 0.63 6.0 450 304 133 90 207 R 2 26
APG.50.11.3 3 x 380 V 1.5 1.1 3450 3.6 0.63 6.0 450 304 133 90 207 R 2 26
APG.50.11.3 3 x 460 V 1.5 1.1 3450 3.0 0.63 6.0 450 304 133 90 207 R 2 26
APG.50.12.1 1 x 230 V 1.5 1.2 3450 8.0 0.82 6.0 450 304 133 90 207 R 2 28 - 30
APG.50.12.A1 1 x 230 V 1.5 1.2 3450 8.0 0.82 6.0 450 304 133 90 207 R 2 28 - 30
APG.50.18.1 1 x 230 V 2.6 1.8 3450 12.0 0.94 6.0 620 408 191 150 265 R 2 36 - 37
APG.50.18.A1 1 x 230 V 2.6 1.8 3450 12.0 0.94 6.0 620 408 191 150 265 R 2 36 - 37
APG.50.19.3 3 x 230 V 2.6 1.9 3450 8.4 0.80 6.0 620 408 191 150 265 R 2 33
APG.50.19.3 3 x 380 V 2.6 1.9 3450 4.9 0.80 6.0 620 408 191 150 265 R 2 33
APG.50.19.3 3 x 460 V 2.6 1.9 3450 4.2 0.80 6.0 620 408 191 150 265 R 2 33
APG.50.29.3 3 x 230 V 3.7 2.9 3450 11.4 0.86 6.0 751 408 191 150 265 R 2 44
APG.50.29.3 3 x 380 V 3.7 2.9 3450 6.4 0.86 6.0 751 408 191 150 265 R 2 44
APG.50.29.3 3 x 460 V 3.7 2.9 3450 5.2 0.86 6.0 751 408 191 150 265 R 2 44
APG.50.30.1 1 x 230 V 3.7 3.0 3450 20.0 0.85 6.0 751 408 191 150 265 R 2 48 - 50
APG.50.30.A1 1 x 230 V 3.7 3.0 3450 20.0 0.85 6.0 751 408 191 150 265 R 2 48 - 50
APG.50.33.1 1 x 230 V 3.7 3.3 3450 20.0 0.80 6.0 751 408 191 150 265 R 2 48 - 50
APG.50.33.A1 1 x 230 V 3.7 3.3 3450 20.0 0.80 6.0 751 408 191 150 265 R 2 48 - 50
* Pump inclusive of cable.
Istart
In---------
49
50
Technical data
APGAPG installations
One-pump installation on auto-coupling
Two-pump installation on auto-coupling
TM0
1 26
06
20
98
•
•
•
•
••
•
••
•
•
•
•
•
•
•
•
• •
••
•
•
•
••
•
•
•
•
•
•
•
••
•
••
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
••
•
••
•
••
•
••
•
••
•
•
•
•
•
•
•
•
••
•
•
•
•
••
•
•
•
•
•
•
•
•
••
•
•
V
U
F
A
G
K
N
L
O
J
C
T
E
S
TM0
1 26
07
209
8
‹‹
‹
‹
‹
‹
‹
‹
‹‹
‹
‹ ‹
‹
‹
‹‹
‹
‹‹‹
‹
‹
‹‹
B
D
I
MM
P R P
Pump type A B C D E F G I J K L M N O P S T U V
APG.50.11.3 ø600 ø600 393 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300
APG.50.12.1 ø600 ø600 393 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300
APG.50.12.A1 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300
APG.50.18.1 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300
APG.50.18.A1 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300
APG.50.19.3 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300
APG.50.29.3 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300
APG.50.30.1 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300
APG.50.30.A1 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300
APG.50.33.1 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300
APG.50.33.A1 ø600 ø600 407 300 45 45 65 115 143 150 400 200 300 700 500 R 2 ½" 160 300
Pump type A B C D E F G I J K L M N O P R S T U V
APG.50.11.3 455 600 393 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300
APG.50.12.1 455 600 393 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300
APG.50.12.A1 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300
APG.50.18.1 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300
APG.50.18.A1 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300
APG.50.19.3 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300
APG.50.29.3 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300
APG.50.30.1 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300
APG.50.30.A1 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300
APG.50.33.1 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300
APG.50.33.A1 455 600 407 135 45 45 65 115 143 150 400 200 300 700 335 330 R 2 ½" 160 300
Accessories LC
107, LCD 107LC 107, LCD 107The LC 107 and LCD 107 pump controllers are designedfor level control, monitoring and protection of GrundfosKP, AP and APG pumping systems up to 23 A/11 kW (P1) per pump starting direct-on-line.
• LC 107 is a one-pump controller.
• LCD 107 is a two-pump controller.
LC 107 and LCD 107 are supplied as a complete controllerincorporating motor protection relay, bell-shaped levelpickups, pneumatic tubes and control unit.
Control is based on pneumatic signals which the LC 107 and LCD 107 receive via pneumatic tubes from 2 or3 level pickups positioned in a pump pit.
The LC 107 and LCD 107 enable:
• control of 1 or 2 pumps based on signals from bell-shaped level pickups,
• automatic pump changeover (even distribution of operating hours on both pumps),
• automatic test run during long periods of inactivity to prevent the shaft from seizing up,
• protection against water hammer as quick restart/simultaneous start is blocked and delayed,
• battery back-up in case of mains supply failure(accessory!),
• starting delay within the range from 0 to 255 sec. (random) after returning from battery operation to mains operation (resulting in an even mains load when several pumping stations are started up at the same time),
• selection of automatic alarm resetting,
• selection of automatic restarting,
• setting of stop delays matching the actual operating conditions,
• indication of liquid level,
• alarm indication of:– too high liquid level, which triggers a high-level
alarm,– overload (via motor protection relay),– overtemperature (via PTC resistance/thermal
switch in motor),– wrong phase sequence,– mains supply failure,– failing level pickup.
As standard, the LC 107 and LCD 107 have two alarmsignal outputs:
• common alarm,
• high-level alarm.
TM0
1 49
21 1
199
TM0
1 49
22 1
199
Settablestop delay Stop of pump
Start of pump
High-level alarm
Pump
LC 107
LCD 107
Pump 2
Pump 1
Settablestop delay
High-level alarmStart of second pump
Start of first pumpCommon stop
51
52
Accessories LLC
C 107, LCD 107 108, LCD 108
Technical dataVoltage tolerances
–15%/+10% of nominal voltage.
Mains frequency
50/60 Hz.
Ambient temperature
• During operation: –30°C to +50°C(must not be exposed to direct sunlight).
• In stock: –30°C to +60°C.
Enclosure class
IP 55.
Pneumatic tubes
• Maximum 20 m per tube(standard: pneumatic tube of 10 metres).
• Diameter: 10 mm.
• Material: PA 11.
Outputs for alarm devices
Max. 400 VAC / max. 2 A / min. 10 mA / AC 1.
LC 108, LCD 108The LC 108 pump controller is a one-pump controllerdesigned for level control, monitoring and protection ofpumps in wastewater, water supply and drainagesystems.
Up to 23 A/11 kW (P1) starting direct-on-line (DOL).Up to 72 A/30 kW (P1) starting star-delta (Y/D).
The LC 108 is supplied as a complete controller incorpo-rating motor protection relay and control unit.
The LC 108 enables:
• control of one pump based on signals from float switches, electrodes or flow switches,
• automatic test run (every 24 hours) during long peri-ods of inactivity to prevent the shaft from seizing up,
• protection against water hammer as quick restart is blocked and delayed (5 seconds),
• selection of automatic alarm resetting,
• selection of automatic restarting (after overtempera-ture),
• setting of stop delays matching the actual operating conditions,
• indication of liquid level,
• alarm indication of:
• - wrong phase sequence,
- inadmissibly high liquid level,
- overload (via motor protection relay),- overtemperature (via PTC resistance or thermal
switch in motor),- defective float switch, electrode or flow switch,
- dry running,
- mains supply failure (by installing a battery back-up which is available as an accessory).
As standard, the LC 108 controller incorporates a buzzerfor indication of alarm.
Furthermore, the controller has one alarm output forcommon alarm.
Applications
The LC 108 can be connected and set to operation/control in 7 different ways:
• systems with 2 float switches,
• systems with 3 float switches,
• systems with 4 float switches,
• systems with 2 electrodes,
• systems with 3 electrodes,
• systems for filling applications,
• systems for drainage applications.
Technical dataVoltage tolerances
–15%/+10% of nominal voltage.
Mains frequency
50/60 Hz.
Ambient temperature
• During operation: –30°C to +50°C(must not be exposed to direct sunlight).
• In stock: –30°C to +60°C.
Enclosure class
IP 55.
Outputs for alarm devices
Max. 400 VAC / max. 2 A / min. 10 mA / AC 1.
Supply system earthing
For TN systems and TT systems.
Rated insulation voltage, Ui
4 kV.
Rated impulse withstand voltage, Uimp
4 kV.
EMC (electromagnetic compatibility)
According to EN 50 081-1 and EN 50 082-2.
Accessories LC
108, LCD 108Level switchesThe AP pumps in combination with LC 108 or LCD 108 areavailable with level switches for automatic level control.Level switches supplied by Grundfos are of the non-mercury type.
LC 108 can be fitted with up to three level switches:
1. Min.: Stops the pump.2. Max.: Starts the pump.3. Alarm: Alarm (optional):
high water level or pump fault.
LCD 108 can be fitted with up to four level switches:
1. Min.: Stops both pumps.2. Max. 1: Starts one pump.3. Max. 2: Starts the other pump.4. Alarm: Alarm (optional):
high water level or pump fault.
The level switches are to be installed in the pit floatingon the pumped liquid.
The position of the level switches decides when LC 108 orLCD 108 starts and stops the AP pumps:
• When the level switch is pointing upwards, the level switch contact will be closed and the pump will start.
• When the level switch is pointing downwards, the the level switch contact will be opened and the pump will stop.
Dimensions
TM0
0 6
678
46
95
ON
OFFTM
01
90
07
030
3
TypeDimensions [mm]
H L B
LC 107, direct-on-lineLCD 107, direct-on-line
350 250 136
LC 108, direct-on-lineLCD 108, direct-on-line
350 250 136
LC 108, Star/delta 590 380 200
LCD 108, Star/delta 635 500 220
B
L
H
53
54
Accessories
AP, KPAccessories for AP, KP stainless steel pumps
Pos.Accessories Pump type
ProductnumberDescription KP
AP12.40
AP12.50
AP35
AP35B
AP50
AP50B
1 Bushing for pipe connection (PVC)Rp 1½/2 ! ! 96 02 38 31
Rp 2/2½ ! ! 96 02 38 32
2 Hose nipple (PVC)
Rp 1½/1½ ! ! 96 00 39 97
Rp 1½/2 ! ! 96 02 38 34
Rp 2/2 ! ! 96 02 38 35
Rp 2/2½ ! ! 96 02 38 36
3 10 m rubber hose incl. clamps (PVC)
1½" ! ! 96 02 38 37
2" ! ! ! ! 96 02 38 38
2½" ! ! 96 02 38 39
4 Connecting piece for rubber hoses (PVC)
RP 1½ ! ! 96 02 38 40
RP 2 ! ! ! ! 96 02 38 41
RP 2½ ! ! 96 02 38 42
5 Non-return valve (PVC)Ball type
Rp 1½ ! ! 96 02 38 43
Rp 2 ! ! ! ! 96 02 38 44
Rp 2½ # ! ! 96 00 20 03
6 Isolating valve (PVC)
Rp 1½ ! ! 96 02 38 46
Rp 2 ! ! ! ! 96 02 38 47
Rp 2½ ! ! 96 02 38 48
7 Hexagon nipple (PVC)
Rp 1½ ! ! 96 02 38 49
Rp 2 ! ! ! ! 96 02 38 50
Rp 2½ ! ! 96 02 38 51
8 Union (PVC)
Rp 1½ ! ! 96 02 38 52
Rp 2 ! ! ! ! 96 02 38 53
Rp 2½ ! ! 96 02 38 54
9 90° pipe bend (PVC)
Rp 1½ ! ! 96 02 38 55
Rp 2 ! ! ! ! 96 02 38 56
Rp 2½ ! ! 96 02 38 57
10Non-return valvefor location in the pump discharge (stainless steel)
Rp 1¼ ! 00 01 52 11
Rp 1½ ! ! 96 00 38 55
Auto-coupling Rp 2/Rp 2 ! ! 96 42 95 19
Hose couplingsScrewed couplings (polyamide)
G 1¼ x ø25 ! 00 ID 35 88
G 1¼ x ø32 ! 00 ID 35 89
G 1¼ x ø40 ! 00 ID 35 90
# Cast iron
TM0
0 5
924
189
5
TM0
0 5
925
18
95
TM0
1 87
08
070
0
3
2
3
4
7
9
8
1
5
7
6
7
1010
10
Accessories
APAccessories for cast iron AP pumpsAccessories Pump type
ProductnumberPos. Description AP30 AP51
AP51Vortex
AP80 APG
10 90° elbowR/Rp 2 ! 96 00 19 80
R/Rp 2½ ! ! 96 00 19 81
11 Coupling halfStorz coupling
Rp 2 2" hose ! ! 96 00 19 82
Rp 2½ - 2" hose ! ! 96 00 19 83
12Ring standEx. 90° elbow
DN 100/DN 100 - 4" hose ! 96 00 34 24
DN 150/DN 100 - 4" hose ! 96 00 38 35
R 2 (1.7/1.8/1.9/3.1 kW) ! 96 00 01 86
13 10 m rubber hoseincl. couplings
2" ! ! 96 00 19 87
14 90° elbowRp/Rp 2 ! ! 96 00 19 90
Rp/Rp 2½ ! ! 96 00 19 91
1590° elbow withflanges
DN 65, PN 10 96 00 36 16
DN 100, PN 10 ! 96 00 36 18
16 Hexagon nippleR/R 2 ! ! 96 00 19 93
R/R 2½ ! ! 96 00 19 94
17 Threaded flange
Rp 2 ! 96 00 44 51
Rp 2½ ! ! 96 00 19 96
Rp 4 ! 96 00 33 36
18 Bolts, nuts and gaskets
4 of each M16 x 65 mm DN 65
! ! 96 00 19 98
8 of each M16 x 65 mm DN 100
! 96 00 38 23
19 Gasket
DN 50 ! 96 00 54 68
DN 65 ! ! 96 00 20 00
DN 100 ! 96 00 33 31
20Discharge pipe with2 flanges , bolts, nuts and gasketsLength = 1 m
DN 65, PN 10 ! ! 96 00 36 10
DN 100, PN 10 ! 96 00 36 12
20aDischarge pipeextension (1 m)
DN 65, PN 10 ! ! 96 00 36 13
DN 100, PN 10 ! 96 00 36 15
21 Non-return valveCast iron ball-typevalve
Rp/Rp 2 ! ! 96 00 20 02
Rp/Rp 2½ ! ! 96 00 20 03
22 Isolating valveBrass
Rp/Rp 2 ! ! 96 00 20 05
Rp/Rp 2½ ! ! 96 00 20 06
23Non-return valveCast iron ball-type valve
DN 65 ! ! 96 00 20 08
DN 100 ! 96 00 20 85
24Isolating valveCast iron
DN 65 ! ! 96 00 20 10
DN 100 ! 96 00 20 12
25 Auto-couplingsystem complete
Rp 2/Rp 2 ! 96 00 01 78
Rp 2/Rp 2 with slant claw ! 96 00 33 41
Rp 2/Rp 2, hook-up ! ! 96 00 44 42
DN 65/Rp 2½ ! ! 96 00 01 80
DN 100/DN 100 ! 96 00 66 58
DN 150/DN 100 ! 96 00 66 59
26 Chain with shackle - galvanized(AP100 up to and including 17 kW)
10 m ! ! ! ! ! 96 00 20 13
6 m ! ! 96 00 36 33
3 m ! ! 96 00 36 34
27Collecting steel pipes for two pumps and 90° out-let, centre discharge flanges are welded. Pipes are painted.
3 x DN 65 ! ! 96 00 36 19
DN 65/65/80 ! ! 96 00 36 20
3 x DN 100 ! 96 00 36 23
28 BasestandDry pit standfor vertical installation incl. 90° suction elbow
DN 100/DN 100 ! 96 00 36 25
29 Cable protection 5 m x 1" ! ! ! ! 96 00 20 84
55
56
Accessories
AP30
Float switch without mercury 1 switch with 10 m cable ! ! ! ! ! 96 00 33 32
Float switch with 20 m cable ! ! ! ! ! 96 00 36 95
Bracket for level switch ! ! ! ! 96 00 33 38
Standard float switch without mercuryWith 10 m cable, counter weightand bracket
1 pump without alarm(2 switches)
! ! ! ! ! 62 50 00 13
1 pump with alarm(3 switches)
! ! ! ! ! 62 50 00 14
2 pumps without alarm(3 switches)
! ! ! ! ! 62 50 00 14
2 pumps with alarm(4 switches)
! ! ! ! ! 62 50 00 15
31 Signal lamp 1 x 230 V Outdoor mounting ! ! ! ! ! 62 50 00 20
32 Acoustic signal (horn) 1 x 230VOutdoor mounting ! ! ! ! ! 62 50 00 21
Indoor mounting ! ! ! ! ! 62 50 00 22
33Discharge pipe with 90° bend and two flanges.For 1 pump.
DN 65, L = 1300 mm ! ! 96 00 38 42
DN 80, L = 1300 mm 96 00 38 43
DN 100, L = 1300 mm ! 96 00 38 44
DN 150, L = 1300 mm ! 96 00 38 45
DN 150, L = 1600 mm ! 96 00 39 79
34Collecting steel pipes for two pumps.Sideways discharge
DN 65, L = 1920 mm ! ! 96 00 38 46
DN 80, L = 1920 mm 96 00 38 47
DN 100, L = 1920 mm ! 96 00 38 48
DN 150, L = 1920 mm ! 96 00 38 49
DN 150, L = 2220 mm ! 96 00 39 80
Accessories Pump typeProductnumberPos. Description AP30 AP51
AP51Vortex
AP80 APG
Accessories
APLevel controllers and accessories
Accessories for controllers
Description
Op
erat
ing
cu
rren
tp
er p
um
p [
A]
Mai
ns
swit
ch
req
uir
ed [
A]
Gru
nd
fos
Pro
du
ct n
o.*
Gru
nd
fos
pro
du
ct n
o.in
clu
din
g h
ou
r co
un
ter*
Gru
nd
fos
pro
du
ct n
o.
incl
ud
ing
sta
rt c
ou
nte
r*
Gru
nd
fos
pro
du
ct n
o.
incl
ud
ing
co
mb
ined
ho
ur
and
sta
rt c
ou
nte
r*
TM0
1 88
74 0
800
LC 107 level controller for 1 pump1 x 230 V, direct-on-line starting
1 - 2.9 25 96 00 24 641.6 - 5.0 25 96 00 24 653.7 - 12.0 25 96 00 24 66
LC 107 level controller for 1 pump3 x 400 V, direct-on-line starting
1 - 2.9 25 96 00 24 671.6 - 5.0 25 96 00 24 683.7 - 12.0 25 96 00 24 6912.0 - 23.0 40 96 00 24 70
TM0
1 88
75 0
800
LCD 107 level controller for 2 pumps1 x 230 V, direct-on-line starting
1 - 2.9 25 96 00 24 711.6 - 5.0 25 96 00 24 723.7 - 12.0 25 96 00 24 73
LCD 107 level controller for 2 pumps3 x 400 V, direct-on-line starting
1 - 2.9 25 96 00 24 741.6 - 5.0 25 96 00 24 753.7 - 12.0 25 96 00 24 7612.0 - 23.0 40 96 00 24 77
TM0
1 88
73 0
800
LC 108 level controller for 1 pump1 x 230 V, direct-on-line starting
1 - 2.9 25 96 43 39 56 96 43 39 57 96 43 39 58 96 43 39 591.6 - 5.0 25 96 43 39 61 96 43 39 60 96 43 39 62 96 43 39 633.7 - 12.0 25 96 43 39 64 96 43 39 65 96 43 39 66 96 43 39 6712.0 - 23.0 40 96 43 39 71 96 43 39 72 96 43 39 73 96 43 39 74
LC 108 level controller for 1 pump3 x 230 V, direct-on-line starting
1 - 2.9 25 96 43 39 75 96 43 39 76 96 43 39 77 96 43 39 781.6 - 5.0 25 96 43 39 79 96 43 39 80 96 43 39 81 96 43 39 823.7 - 12.0 25 96 43 39 83 96 43 39 84 96 43 39 85 96 43 39 8612.0 - 23.0 40 96 43 39 87 96 43 39 88 96 43 39 89 96 43 39 90
LC 108 level controller for 1 pump3 x 400 V, direct-on-line starting
1 - 2.9 25 96 43 39 91 96 43 39 92 96 43 39 93 96 43 39 941.6 - 5.0 25 96 43 39 95 96 43 39 96 96 43 39 97 96 43 39 983.7 - 12.0 25 96 43 39 99 96 43 40 00 96 43 40 01 96 43 40 0212.0 - 23.0 40 96 43 40 03 96 43 40 04 96 43 40 05 96 43 40 06
LC 108 level controller for 1 pump3 x 400 V, star-delta starting
6.4 - 20.0 25 96 43 79 2820.8 - 30.0 40 96 43 79 5020.8 - 59.0 80 96 43 79 7024.2 - 72.0 96 43 79 90
TM0
1 88
76 0
800
LCD 108 level controller for2 pumps3 x 230 V, direct-on-line starting
1 - 2.9 25 96 43 40 23 96 43 40 24 96 43 40 25 96 43 40 261.6 - 5.0 25 96 43 40 27 96 43 40 28 96 43 40 29 96 43 40 303.7 - 12.0 25 96 43 40 31 96 43 40 32 96 43 40 33 96 43 40 3412.0 - 23.0 40 96 43 40 35 96 43 40 36 96 43 40 37 96 43 40 38
LCD 108 level controller for2 pumps3 x 400 V, direct-on-line starting
1 - 2.9 25 96 43 40 39 96 43 40 40 96 43 40 41 96 43 40 421.6 - 5.0 25 96 43 40 43 96 43 40 44 96 43 40 45 96 43 40 463.7 - 12.0 40 96 43 40 47 96 43 40 48 96 43 40 49 96 43 40 5012.0 - 23.0 60 96 43 40 51 96 43 40 52 96 43 40 53 96 43 40 54
LCD 108 level controller for2 pumps3 x 400 V, star-delta starting
6.4 - 20.0 25 96 43 80 3220.8 - 30.0 40 96 43 80 5220.8 - 59.0 80 96 43 80 7224.2 - 72.0 96 43 80 92
*Includes Instruction and operating manual in English. Other languages are available on request.
Description Grundfos product no.
Battery back-up 96 00 25 20Flashing beacon for external alarm indication 62 50 00 20Alarm horn for external alarm indication (outdoor installation) 62 50 00 21Alarm horn for external alarm indication (indoor installation) 62 50 00 22Hour counter [230 V] 96 00 25 14Hour counter [400 V] 96 00 25 15Start counter [230 V] 96 00 25 16Start counter [400 V] 96 00 25 17Combined hour and start counter [230 V] 96 00 25 18Combined hour and start counter [400 V] 96 00 25 1925 [A] external mains switch for supply cable 96 00 25 1140 [A] external mains switch for supply cable 96 00 25 1280 [A] external mains switch for supply cable 96 00 25 13LC-Ex4 96 44 03 00
57
58
Accessories
APFree-standing installation or portable
Installation on auto-coupling
Vertical dry installation (D)
Installation on auto-coupling
TM0
1 25
42 2
09
8TM
01
2543
20
98
AP30AP51AP51 VortexAP80APG
12
10
11
13
AP30AP51AP51 VortexAPG
17
18
14
25
26
16
22
25
25
19
21
R2/DN65
TM0
1 0
749
139
8TM
00
56
16 1
398
28
24
23
20
15
15
24
AP80
19
24
25
26
17
23
25
25
18
20
15
DN80/DN100/DN150/DN200/DN250/DN300/
AP80
Accessories
AP, APGLevel controllers and accessories Pipe dimensions
s
s
TM0
0 3
618
079
4TM
01
69
82 3
99
9TM
01
7286
429
9TM
01
7187
40
99
2929
30
31
32
TM0
1 0
753
219
7
Dimensions DN 1 DN 2 A B C Prod. no.
3 x DN 65, PN 10 65 65 140 140 380 96 00 36 19
DN 65/ 65/ 80, PN 10 65 80 140 235 380 96 00 36 20
3 x DN 100, PN 10 100 100 205 205 611 96 00 36 23
TM0
1 0
898
149
8
Dimensions A Prod. no.
2 x DN 65, PN 10 1300 96 00 38 42
2 x DN 100, PN 10 1300 96 00 38 44
2 x DN 150, PN 10 for 1.5 m pit 1300 96 00 38 45
2 x DN 150, PN 10 for 2.0 m pit 1300 96 00 38 79
TM0
1 0
899
379
7
Dimensions A B C Prod. no.
3 x DN 65, PN 10 620 1300 1920 96 00 38 46
3 x DN 100, PN 10 620 1300 1920 96 00 38 48
3 x DN 150, PN 10 for 2.0 m pit 620 1300 1920 96 00 38 49
3 x DN 150, PN 10 for 2.5 m pit 620 1600 2220 96 00 39 80
C A
B
DN1DN22727
C A
DN 1
DN 2
B
37
A
33
A
38
BAC
34
A B
C
59
60
Product range
KPKP 150
KP 250
KP 350
Pump type Voltage Float switchVertical
level switch3 m cable 5 m cable 10 m cable With plug Plug type
Dischargeconnection
Product no.
KP 150 1 x 100 V ! ! Japan Rp 1¼ 01 1B B1 00
KP 150 1 x 100 V ! ! ! Japan Rp 1¼ 01 1B B7 00
KP 150 1 x 115 V ! 10 ft ! USA NPT 1¼ 01 1D C0 01
KP 150 1 x 115 V ! 25 ft ! USA NPT 1¼ 01 1D C2 01
Pump type Voltage Float switchVertical
level switch3 m cable 5 m cable 10 m cable With plug Plug type
Dischargeconnection
Product no.
KP 250 1 x 100 V ! ! Japan Rp 1¼ 01 2B B1 00
KP 250 1 x 100 V ! ! ! Japan Rp 1¼ 01 2B B7 00
KP 250 1 x 115 V 10 ft ! USA NPT 1¼ 01 2D C0 01
KP 250 1 x 115 V 25 ft ! USA NPT 1¼ 01 2D C2 01
KP 250 1 x 220 V ! ! Rp 1¼ 01 2G 66 00
KP 250 1 x 220 V ! ! Rp 1¼ 01 2G 64 00
KP 250 1 x 220 V ! ! Rp 1¼ 01 2G 68 00
KP 250 1 x 220 V ! ! Rp 1¼ 01 2G 69 00
KP 250 3 x 200 V ! Rp 1¼ 01 2F 61 00
Pump type Voltage Float switchVertical
level switch3 m cable 5 m cable 10 m cable With plug Plug type
Dischargeconnection
Product no.
KP 350 1 x 100 V ! ! Japan Rp 1¼ 01 3B B1 00
KP 350 1 x 100 V ! ! ! Japan Rp 1¼ 01 3B B7 00
KP 350 1 x 115 V 10 ft ! USA NPT 1¼ 01 3D C0 01
KP 350 1 x 115 V 25 ft ! USA NPT 1¼ 01 3D C2 01
KP 350 1 x 220 V ! ! Rp 1¼ 01 3G 66 00
KP 350 1 x 220 V ! ! Rp 1¼ 01 3G 64 00
KP 350 1 x 220 V ! ! Rp 1¼ 01 3G 68 00
KP 350 1 x 220 V ! ! Rp 1¼ 01 3G 69 00
KP 350 3 x 200 V ! Rp 1¼ 01 3F 61 00
Product range
AP12, AP30AP12
AP30
Pump type VoltageControl boxwith 0.8 m
supply cableLevel switch 10 m cable 3 m cable Product no.
AP12.40.04.A1 1 x 220 - 230 V ! 96 02 39 21
AP12.40.04.A1 1 x 220 - 230 V ! ! 96 02 39 22
AP12.40.04.1 1 x 220 - 230 V ! 96 02 39 23
AP12.40.04.3 3 x 380 - 440 V ! 96 01 10 29
AP12.40.04.A3 3 x 380 - 440 V ! ! ! 96 01 10 42
AP12.40.04.3 3 x 200 - 220 V ! 96 01 10 27
AP12.40.04.A3 3 x 200 - 220 V ! ! ! 96 01 10 40
AP12.40.06.A1 1 x 220 - 230 V ! ! 96 01 06 54
AP12.40.06.1 1 x 220 - 230 V ! 96 01 06 59
AP12.40.06.3 3 x 380 - 440 V ! 96 00 17 76
AP12.40.06.A3 3 x 380 - 440 V ! ! ! 96 01 09 38
AP12.40.06.3 3 x 200 - 220 V ! 96 01 08 95
AP12.40.06.A3 3 x 200 - 220 V ! ! ! 96 01 09 37
AP12.40.08.A1 1 x 220 - 230 V ! ! 96 01 06 60
AP12.40.08.1 1 x 220 - 230 V ! 96 01 06 65
AP12.40.08.3 3 x 380 - 440 V ! 96 01 06 41
AP12.40.08.A3 3 x 380 - 440 V ! ! ! 96 01 09 41
AP12.40.08.3 3 x 200 - 220 V ! 96 01 08 96
AP12.40.08.A3 3 x 200 - 220 V ! ! ! 96 01 09 40
AP12.50.11.A1 1 x 220 - 230 V ! ! 96 01 06 78
AP12.50.11.1 1 x 220 - 230 V ! 96 01 06 82
AP12.50.11.3 3 x 380 - 440 V ! 96 01 06 42
AP12.50.11.A3 3 x 380 - 440 V ! ! ! 96 01 09 44
AP12.50.11.3 3 x 200 - 220 V ! 96 01 08 97
AP12.50.11.A3 3 x 200 - 220 V ! ! ! 96 01 09 43
Pump type VoltageControl boxwith 0.8 m
supply cableLevel switch 10 m cable Product no.
AP30.50.09.1.V 1 x 230 V ! ! 96 00 34 68
AP30.50.09.A1.V 1 x 230 V ! ! ! 96 00 34 69
AP30.50.09.3.V 3 x 230 V ! 96 00 34 70
AP30.50.09.3.V 3 x 380 V ! 96 00 34 71
AP30.50.09.3.V 3 x 460 V ! 96 00 34 72
AP30.50.13.1.V 1 x 230 V ! ! 96 00 34 73
AP30.50.13.A1.V 1 x 230 V ! ! ! 96 00 34 74
AP30.50.14.3.V 3 x 230 V ! 96 00 34 75
AP30.50.09.3.V 3 x 380 V ! 96 00 34 76
AP30.50.09.3.V 3 x 460 V ! 96 00 34 77
61
62
Product range AP35, AP35B
, AP50, AP50BAP35
AP35B
AP50
AP50B
Pump type VoltageControl boxwith 0.8 m
supply cableLevel switch 10 m cable 3 m cable Product no.
AP35.40.06.A1.V 1 x 220 - 230 V ! ! 96 01 06 66
AP35.40.06.1.V 1 x 220 - 230 V ! 96 01 06 71
AP35.40.06.3.V 3 x 380 - 440 V ! 96 01 06 43
AP35.40.06.A3.V 3 x 380 - 440 V ! ! ! 96 01 09 47
AP35.40.06.3.V 3 x 200 - 220 V ! 96 01 08 98
AP35.40.06.A3.V 3 x 200 - 220 V ! ! ! 96 01 09 46
AP35.40.08.A1.V 1 x 220 - 230 V ! ! 96 01 06 72
AP35.40.08.1.V 1 x 220 - 230 V ! 96 01 06 77
AP35.40.08.3.V 3 x 380 - 440 V ! 96 01 06 44
AP35.40.08.A3.V 3 x 380 - 440 V ! ! ! 96 01 09 50
AP35.40.08.3.V 3 x 200 - 220 V ! 96 01 08 99
AP35.40.08.A3.V 3 x 200 - 220 V ! ! ! 96 01 09 49
Pump type Voltage Float switch 10 m cable 5 m cable With plug Product no.
AP35B.50.06.1.V 1 x 220-230 V ! ! 96 00 45 69
AP35B.50.06.A1.V 1 x 220-230 V ! ! ! 96 00 45 68
AP35B.50.06.3.V 3 x 200-220 V ! 96 00 45 71
AP35B.50.08.1.V 1 x 220-230 V ! ! 96 00 45 81
AP35B.50.08.A1.V 1 x 220-230 V ! ! ! 96 00 45 80
AP35B.50.08.3.V 3 x 200-220 V ! 96 00 45 83
Pump type VoltageControl boxwith 0.8 m
supply cableLevel switch 10 m cable 3 m cable Product no.
AP50.50.08.A1.V 1 x 220 - 230 V ! ! 96 01 06 84
AP50.50.08.1.V 1 x 220 - 230 V ! 96 01 06 88
AP50.50.08.3.V 3 x 380 - 440 V ! 96 01 06 47
AP50.50.08.A3.V 3 x 380 - 440 V ! ! ! 96 01 09 53
AP50.50.08.3.V 3 x 200 - 220 V ! 96 01 09 00
AP50.50.08.A3.V 3 x 200 - 220 V ! ! ! 96 01 09 52
AP50.50.11.A1.V 1 x 220 - 230 V ! ! 96 01 06 90
AP50.50.11.1.V 1 x 220 - 230 V ! 96 01 06 94
AP50.50.11.3.V 3 x 380 - 440 V ! 96 01 06 45
AP50.50.11.A3.V 3 x 380 - 440 V ! ! ! 96 01 09 56
AP50.50.11.3.V 3 x 200 - 220 V ! 96 01 09 01
AP50.50.11.A3.V 3 x 200 - 220 V ! ! ! 96 01 09 55
Pump type Voltage Float switch 10 m cable 5 m cable With plug Product no.
AP50B.50.08.1.V 1 x 220-230 V ! ! 96 00 45 93
AP50B.50.08.A1.V 1 x 220-230 V ! ! ! 96 00 45 92
AP50B.50.08.3.V 3 x 200-220 V ! 96 00 45 95
AP50B.50.11.1.V 1 x 220-230 V ! ! 96 00 46 05
AP50B.50.11.A1.V 1 x 220-230 V ! ! ! 96 00 46 04
AP50B.50.11.3.V 3 x 200-220 V ! 96 00 46 07
AP50B.50.15.3.V 3 x 200-220 V ! 96 00 46 11
Product range AP51,
AP51 VortexAP51 with single-vane impeller
AP51 Vortex impeller
Pump type VoltageControl boxwith 0.8 m
supply cableLevel switch 10 m cable Product no.
AP51.65.09.1 1 x 230 V ! ! 96 00 34 93
AP51.65.09.A1 1 x 230 V ! ! ! 96 00 34 94
AP51.65.09.3 3 x 230 V ! 96 00 34 95
AP51.65.09.3 3 x 380 V ! 96 00 34 96
AP51.65.09.3 3 x 460 V ! 96 00 34 97
AP51.65.13.1 1 x 230 V ! ! 96 00 35 57
AP51.65.13.A1 1 x 230 V ! ! ! 96 00 35 58
AP51.65.14.3 3 x 230 V ! 96 00 35 59
AP51.65.14.3 3 x 380 V ! 96 00 35 60
AP51.65.14.3 3 x 460 V ! 96 00 35 61
AP51.65.15.3 3 x 230 V ! 96 00 35 62
AP51.65.15.3 3 x 380 V ! 96 00 35 63
AP51.65.15.3 3 x 460 V ! 96 00 35 64
AP51.65.22.3 3 x 230 - 380 V ! 96 00 35 65
AP51.65.22.3 3 x 460 V ! 96 00 35 66
AP51.65.23.3 3 x 230 - 380 V ! 96 00 35 67
AP51.65.23.3 3 x 460 V ! 96 00 35 68
AP51.65.34.3 3 x 230 - 380 V ! 96 00 35 71
AP51.65.34.3 3 x 460 V ! 96 00 35 72
AP51.65.35.3 3 x 230 - 380 V ! 96 00 35 69
AP51.65.35.3 3 x 460 V ! 96 00 35 70
Pump type VoltageControl boxwith 0.8 m
supply cableLevel switch 10 m cable Product no.
AP51.65.14.1.V 1 x 230 V ! ! 96 00 34 78
AP51.65.14.A1.V 1 x 230 V ! ! ! 96 00 34 79
AP51.65.14.3.V 3 x 230 V ! 96 00 34 80
AP51.65.14.3.V 3 x 380 V ! 96 00 34 81
AP51.65.14.3.V 3 x 460 V ! 96 00 34 82
AP51.65.15.3.V 3 x 230 - 380 V ! 96 00 34 83
AP51.65.15.3.V 3 x 460 V ! 96 00 34 84
AP51.65.23.3.V 3 x 230 - 380 V ! 96 00 34 85
AP51.65.23.3.V 3 x 460 V ! 96 00 34 86
AP51.65.34.3.V 3 x 230 - 380 V ! 96 00 34 87
AP51.65.34.3.V 3 x 460 V ! 96 00 34 88
AP51.65.35.3.V 3 x 230 - 380 V ! 96 00 34 89
AP51.65.35.3.V 3 x 460 V ! 96 00 34 90
AP51.65.36.3.V 3 x 230 - 380 V ! 96 00 34 91
AP51.65.36.3.V 3 x 460 V ! 96 00 34 92
63
64
Product range
AP80, APGAP80
APG
Pump type Voltage 10 m cable Product no.
AP80.100.15 3 x 230 V ! 96 00 45 00
AP80.100.15 3 x 380 V ! 96 00 45 01
AP80.100.15 3 x 400 V ! 96 00 45 02
AP80.100.15 3 x 460 V ! 96 00 45 03
AP.80.100.21 3 x 230 V ! 96 00 45 04
AP.80.100.21 3 x 380 V ! 96 00 45 05
AP.80.100.21 3 x 400 V ! 96 00 45 06
AP.80.100.21 3 x 460 V ! 96 00 45 07
AP80.100.27 3 x 230 V ! 96 00 45 08
AP80.100.27 3 x 380 V ! 96 00 45 09
AP80.100.27 3 x 400 V ! 96 00 45 10
AP80.100.27 3 x 460 V ! 96 00 45 11
AP80.100.35 3 x 230 V ! 96 00 45 12
AP80.100.35 3 x 380 V ! 96 00 45 13
AP80.100.35 3 x 400 V ! 96 00 45 14
AP80.100.35 3 x 460 V ! 96 00 45 15
AP80.100.47 3 x 230 V ! 96 00 45 16
AP80.100.47 3 x 380 V ! 96 00 45 17
AP80.100.47 3 x 400 V ! 96 00 45 18
AP80.100.47 3 x 460 V ! 96 00 45 19
AP80.100.65 3 x 230 V ! 96 00 45 20
AP80.100.65 3 x 380 V ! 96 00 45 21
AP80.100.65 3 x 400 V ! 96 00 45 22
AP80.100.65 3 x 460 V ! 96 00 45 23
AP80.100.74 3 x 230 V ! 96 00 45 24
AP80.100.74 3 x 380 V ! 96 00 45 25
AP80.100.74 3 x 400 V ! 96 00 45 26
AP80.100.74 3 x 460 V ! 96 00 45 27
AP80.100.87 3 x 230 V ! 96 00 45 28
AP80.100.87 3 x 380 V ! 96 00 45 29
AP80.100.87 3 x 400 V ! 96 00 45 30
AP80.100.87 3 x 460 V ! 96 00 45 31
AP80.100.107 3 x 230 V ! 96 00 45 32
AP80.100.107 3 x 380 V ! 96 00 45 33
AP80.100.107 3 x 400 V ! 96 00 45 34
AP80.100.107 3 x 460 V ! 96 00 45 35
Pump type VoltageControl box
with 0.8 m supply cableLevel switch 10 m cable Product no.
APG.50.12.1 1 x 230 V ! ! 96 00 35 16
APG.50.12.A1 1 x 230 V ! ! ! 96 00 35 17
APG.50.11.3 3 x 230 V ! 96 00 35 84
APG.50.11.3 3 x 380 V ! 96 00 35 85
APG.50.11.3 3 x 460 V ! 96 00 35 20
APG.50.18.1 1 x 230 V ! ! 96 00 35 21
APG.50.18.A1 1 x 230 V ! ! ! 96 00 35 22
APG.50.19.3 3 x 230 - 380 V ! 96 00 35 23
APG.50.19.3 3 x 460 V ! 96 00 35 24
APG.50.30.1 1 x 230 V ! ! 96 00 35 25
APG.50.30.A1 1 x 230 V ! ! ! 96 00 35 26
APG.50.29.3 3 x 230 - 380 V ! 96 00 35 27
APG.50.29.3 3 x 460 V ! 96 00 35 28
APG.50.33.1 1 x 230 V ! ! 96 00 35 29
APG.50.30.A1 1 x 230 V ! ! ! 96 00 35 30
65
66
67
www.grundfos.com
V7 11 82 80 03 03GBRepl. V7 11 82 80 09 00 Subject to alterations.
GRUNDFOS A/S . DK-8850 Bjerringbro . DenmarkTelephone: +45 87 50 14 00.
Being responsible is our foundationThinking ahead makes it possible
Innovation is the essence