fremap osram sylvania catalog

22
OSRAM SYLVANIA—Air Heaters 131 Portsmouth Avenue, Exeter, NH 03833 USA Tel. 603-772-4331 Fax 603-772-1072 www.sylvaniaheaters.com

Upload: fremap-industries-s-a

Post on 12-Nov-2014

1.002 views

Category:

Documents


3 download

DESCRIPTION

General catalog with the all air heaters

TRANSCRIPT

Page 1: Fremap Osram Sylvania Catalog

OSRAM SYLVANIA—Air Heaters 131 Portsmouth Avenue, Exeter, NH 03833 USA Tel. 603-772-4331 Fax 603-772-1072 www.sylvaniaheaters.com

Page 2: Fremap Osram Sylvania Catalog

WARNING: OSRAM SYLVANIA Air/Inert Gas Heaters should be used to heat air or an inert gas only. Use with explosive gases or in an explosive ambient can result in an explosive event, possibly leading to a serious accident or injury.

Aerospace:• Combustion/flow simulation

Packaging:• High speed poly-coated

paperboard sealing• High speed heat shrink

installations• Forming• Curing adhesives• Sterilizing bottles or cartons

Automotive• Hot air bonding of body

panels• Curing adhesives• Vacuum forming• Simulation of engine exhaust• Fuel Cell testing

Plastics/Rubber:• Salt removal from rubber

extrusions• Bending and forming of

plastics• De-flashing of molded parts

Textiles:• Welding plastic or vinyl

fabrics• Heat treating specialty

fabrics

Semiconductor and Electronics:• Air knife in wave solder

machines• Soldering/desoldering

PC boards, lead frames, capacitors

• Wafer and PC board drying• Heat shrinking wire

insulation• Preheating process gases

Sterilization:• Pharmaceuticals• Medical/surgical hardware• Packaging materials

Paper/Printing• Speed drying coated paper• Adhesive activation• Ink drying

Page 3: Fremap Osram Sylvania Catalog

1

OSRAM SYLVANIA—Air Heaters 131 Portsmouth Avenue, Exeter, NH 03833 USA Tel. 603-772-4331 Fax 603-772-1072

Max Max Product Features kW Air Temp Air Press Use with Page °F (°C) PSI (Bar) Blower?

Basic heater with quartz insulator tube. Ideal for

“spot” heating applications.

Compact size. Built in “K” thermocouple allows for

precise ±1 degree control.

Triple-pass exchanger housing improves

efficiency and safety.

Serpentine element in high-pressure pipe for

critical processes.

All-purpose heater with two built-in “K” thermocouples

for precise control and overtemp protection.

All-purpose heater with two built-in “K” thermocouples

for precise control and overtemp protection.

Heavy-duty flanged heater for high-pressure and flow applications. “K” thermo-couples measure phase

temperatures and provide overtemp protection.

Series I, II, III

Hot Air Tool

Serpentine II, VI

Threaded Inline

SureHeat® JET

SureHeat® MAX

Flanged Inline

0.6 – 2.4 1 phase

1.5 – 3.5 1 phase

2.0 – 8.0 1 phase

1.6 – 18.0 1/3 phase

3.0 – 8.0 1 phase

6.0 – 36.0 1/3 phase

36.0–192.0 3 phase

1600 (871)

1400 (760)

1500 (815)

1400 (760)

1400 (760)

1400 (760)

1400 (760)

7 (0.5)

60 (4)

25 (1.7)

150 (10)

60 (4)

60 (4)

150 (10)

No

No

No

No

Yes

Yes

Yes

With air temperatures controllable to 1400°F ±1°, SYLVANIA Air Heaters are your solution for many critical applications. Whether you are sealing, melting, drying, sterilizing, bonding, or soldering, SYLVANIA Air Heaters with our patented Serpentine coil give you the control, precision, and long life you need for greater productivity.

4

6

8

10

12

14

16

Page 4: Fremap Osram Sylvania Catalog

Selecting an Air Heater

The energy (kW) requirement is calculated from the following formula:

SCFM = Air flow in Standard* Cubic Feet per MinuteTinlet = Inlet Air Temperature (°F) (typically 70°F)Texit = Desired Exit Air Temperature (°F)

Example: Heating 10 SCFM from ambient temperature (70°F) to 800°F:

kW = 10 SCFM x (800°F – 70°F) = 2.9 kW 2500

Conversion Formulas: (Liters per Minute)/28.3 = Cubic Feet per Minute°C = 5/9 (°F – 32)°F = 9/5°C + 32

*Please refer below for an explanation of Standard flowrate

Air Sourcespressure air for your air heating system. Blower size is based on the maximum amount of airflow (CFM or LPM) it can produce without any inlet or exit restrictions. When a heater or other restriction is attached to a blower, the maximum flow decreases. If the blower is severely restricted, the blower motor can overheat and fail.

When designing your heating system, you should try to minimize air restrictions, and select a blower sufficient to overcome the backpressure generated by the heater, flare, and associated piping. Because of their small size,

the Series, Hot Air Tool, and Serpentine II heaters should not be used with regenerative blowers.

Compressed AirCompressed air is commonly available in most factories. It is high-pressure regulated air (typically to 100psi), and often contains oil for lubricating pneumatic valves and equip-ment. You must filter this oil to prevent fouling and damage to OSRAM SYLVANIA’s electric air heater elements.

When measuring compressed air flow rates, be sure you are measuring Standard CFM

If used properly, heater life of 5000 hours or greater can be expected. To ensure long heater life and safe opera-tion, follow these guidelines. Also read and understand your heater Operating Manual before use. Failure to follow these guidelines can result in heater damage, failure, or personal injury.

Air SourcesIn general, compressed air, and air from regenerative blowers may be used to supply OSRAM SYLVANIA air heaters. Your air source should be clean and dry. Dirt, grease, oil, or oil vapors, or corrosive or reactive gases will damage an air heater. Also, use air or inert gas only. Do not use with volatile or combustible gases.

Regenerative BlowersRegenerative blowers are compact and inexpensive clean air sources. They can provide large amounts of low-

or Standard LPM units. The “Standard” means that the units are measured at standard temperature and pressure. Many flow meters are labeled SCFM, but this is incorrect at the higher pressures produced by compressed air. For accurate flow measurements, you must consult your flow meter manual for converting CFM to “Standard” CFM. In the diagram below, the flow meter reading (CFM) is converted to SCFM using a Dwyer ball-type flow meter conversion.

2

kW = SCFM x (Texit – Tinlet) 2500

Page 5: Fremap Osram Sylvania Catalog

For detailed operating instructions,

visit www.sylvaniaheaters.com

OSRAM SYLVANIA—Air Heaters 131 Portsmouth Avenue, Exeter, NH 03833 USA Tel. 603-772-4331 Fax 603-772-1072

Closed-Loop (Feedback) ControlA closed-loop heater control system uses a power control-ler, temperature controller, and thermocouple to provide a constant output temperature, regardless of changes in air-flow. The temperature controller also provides a convenient display of your process air temperature.

Power ControllerPhase angle fired SCR (Silicon Controlled Rectifier) power con-trols will provide the smoothest power regulation for OSRAM SYLVANIA Air Heaters.

Other power controls may be suitable, such as distributive zero cross SSR (Solid State Relays) or other fast-switching SSR’s, but you should contact OSRAM SYLVANIA for approval before use.

Temperature ControllerUse only digital temperature controls with type-K thermo-couple inputs. The temperature control output must match the input of the power control. (i.e. 4-20mA, or 0-10VDC).

A standard PID-type control with a wide proportional band setting will work best to mini-mize temperature overshoot.

PID parameters may be auto-tuned, but only at tem-peratures well below the maximum of the heater. If the temperature rises too high during auto-tune, turn power off immediately.

When using a Solid State Relay power control, the temperature controller cycle time should be set for 100ms or less.

A good control system is critical for long heater life. Before turning your control sys-tem on, you must have sufficient airflow through the heater before applying power. (Applies to heaters without SureHeat or Hot Air System over-temperature protection.) Only qualified individuals should install OSRAM SYLVANIA heat-ers and controls. Follow all applicable electrical codes and use proper wiring.

Open-Loop (Manual) ControlThis simple method of control uses a manually operated power controller to apply a fixed voltage to the heating element. Using this system, the operator manually adjusts the controller to change heater temperature. Note that if the airflow is suddenly interrupted, the element could fail. The open-loop controller is generally used with OSRAM SYLVANIA’s Series heaters.

ThermocoupleUse only a fine-wire (.030” max wire dia.), exposed- junction, type-K thermocouple placed within 1” of the heater exit for accurate temperature readings. Other thermocouple styles, or varying the distance from the heater exit will result in temperature measurement errors and/or heater failure.

Controls

3

Page 6: Fremap Osram Sylvania Catalog

Specifications• Air temperatures to 1600˚F

(871˚C)

• Quartz outer tube housing.

• Nozzled (Style B) or open-ended (Style A) design

• High-temperature silicone rubber Rear Adapter/ Terminal Assembly

• Maximum air pressure 7 PSI (0.5 bar)

• Maximum inlet temperature 120˚F (49˚C)

• CE compliant

Performance

4

1600

1400

1200

1000

800

600

400

0

Air

Tem

per

atur

e ˚F

0 25 50 100 200 300 400 500 600Air Flow in SCFH

Series Heaters

0 11.75 23.5 47 94 142 189 236 283871

760

649

538

427

316

204

0

Air

Tem

per

atur

e ˚C

Air Flow in SLPM

Series ISeries IISeries III

Page 7: Fremap Osram Sylvania Catalog

For detailed operating instructions,

visit www.sylvaniaheaters.com

Mtg. ScrewNo. 3-48

Clamp

NutLockwasher

Terminal

1.37"

(34mm)

"A"OD "B"

"A"1.00" (2

5.4mm)

ID "C"

Style A Tube

Style B Tube

Adapter for nylon pressure tubing

OSRAM SYLVANIA—Air Heaters 131 Portsmouth Avenue, Exeter, NH 03833 USA Tel. 603-772-4331 Fax 603-772-1072

Part Number Tube Style Max. Watts Max. Volts Tube Length Tube O.D. Nozzle I.D. (Style B) “A” “B” “C”

Series I

010226 A 1050 180 6.88" .41" — (175mm) (10mm) —

014372 A 1000 130 7.75" .41" — (197mm) (10mm) —

014682 B 680 145 7.88" .41" .07" (200mm) (10mm) (2mm)

014683 B 650 105 8.75" .41" .07" (222mm) (10mm) (2mm)

Series II

016501 A 1125 130 3.88" .41" — (98mm) (10mm) —

016503 A 850 80 3.88" .41" — (98mm) (10mm) —

016502 B 600 95 4.88" .41" .07" (124mm) (10.4mm) (2mm)

016504 B 650 70 4.88" .41" .07" (124mm) (10mm) (2mm)

Series III

017558 A 2050 160 6.88" .59" — (175mm) (15mm) —

017575 B 1450 135 7.88" .59" .12" (200mm) ( 15mm) (3mm)

AccessoriesPart Number Description

057081 Open Loop (Manual) power controller 25A

Outer Shields — Open End

015509 For Series I 014372017853 For Series II

Outer Shields — Flared

037261 For Series I 010226, 014682

5

Products

Installation

Page 8: Fremap Osram Sylvania Catalog

Specifications• Air temperatures control-

lable to 1400˚F (760˚C)

• Built-in “K” type thermo- couple

• 1/4” hose barb air connection

• Maximum inlet temperature 120˚F (49˚C)

• Maximum air pressure 60 PSI (4Bar)

• Slotted exit for flare attachment

• 304 Stainless Steel body

• 3’ (914mm) power and thermocouple leads

• CE compliant

0 500 1000 1500

0 200 400 600800

650

500

350

1500

1300

1100

900

700

500

Tem

per

atur

e ˚F

Tem

per

atur

e ˚C

Air Flow in SCFH

Air Flow in SLPM

1500W / 120V2000W / 240V3500W / 240V

Hot Air ToolsPerformance

6 7

Page 9: Fremap Osram Sylvania Catalog

For detailed operating instructions,

visit www.sylvaniaheaters.com

OSRAM SYLVANIA—Air Heaters 131 Portsmouth Avenue, Exeter, NH 03833 USA Tel. 603-772-4331 Fax 603-772-1072

6 7

Installation

.81" (20.6mm) Dia.

8.88" (225.6mm)

Hose Barb

.74" (18.8mm)ID

.62" (15.8mm)

Electrical & TC Leads

.88" (22.4mm)Dia.

2.19"(55.6mm)

.06"x 2.5" Opening(1.52mm x 63.5mm)

FLARE

1.25"(31.7mm)

.12" Opening(3.05mm)

NOZZLE

Accessories

Part Max. Max. Max. Min. Number Watts Volts Amps Flow SCFH (SLPM)

068462 1500W 120 13 30 (14)

068463 2000W 240 9 70 (33)

068464 3500W 240 15 90 (43)

Products

Part Number Description

068472 Flare (includes clamp) .06" x 2.5" (1.52mm x 63.5mm) opening

057081 Open Loop (manual) Power Control, 25A, 240V, 1

066823 Closed Loop Power Control, 30A, 240V, 4–20mA (used with 070429)

070429 Digital Temperature Control, 1/16 DIN (used with 066823), 4–20mA

Page 10: Fremap Osram Sylvania Catalog

Specifications

• Air temperatures controllable to 1500˚F (815˚C)

• Serpentine II to 3.6kW

• Serpentine VI to 8.0kW

• Triple Pass Heat Exchanger uses incoming air to cool outer shell

• Maximum air pressure 25 PSI (1.7 bar)

• Replaceable element assemblies

• CE compliant

Tem

per

atu

re ˚

F

Serpentine II Maximum Performance

Tem

per

atu

re ˚

C

Air Flow in SCFH

1600

1400

1200

1000

800

600

400

200

00 200 400 600 800 1000 1200

871

760

649

538

427

316

204

93.4

0

0 94 189 283 378 472 566Air Flow in SLPM

2 kW2.8 kW3.6 kW3.6 kW (Two-stage)

Tem

per

atu

re ˚

F

Serpentine VI Maximum Performance

Tem

per

atu

re ˚

C

Air Flow in SCFH

1600

1400

1200

1000

800

600

400

200

00 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400

871

760

649

538

427

316

204

93.4

0

0 94 189 283 378 472 566 661 755 850 944 1045 1133Air Flow in SLPM

5 kW6 kW6 kW (Two-stage)8 kW

8 9

Performance

Page 11: Fremap Osram Sylvania Catalog

For detailed operating instructions,

visit www.sylvaniaheaters.com

OSRAM SYLVANIA—Air Heaters 131 Portsmouth Avenue, Exeter, NH 03833 USA Tel. 603-772-4331 Fax 603-772-1072

8 9

Element

Housing Assemblies

Part Serpentine “A” “B” “C” “D” “E” Number Type

029763 ll 1.6" 9.0" 10.0" 0.7" 3/8" NPT (40mm) (229mm) (254mm) (18mm)

057088 Vl 2.1" 11.9" 12.9" 1.4" 3/4" NPT (54mm) (302mm) (327mm) (35mm)

“A”

“B”

Installation

12" (304.8mm)Leads

“B”“C”

“A” Dia.

“D” Dia.

“E” NPT

Air Inlet

Serpentine II Elements used with housing 029763

Part Max. Max. Max. Length “A” O.D. “B” Number Watts Volts Amps

029765 2kW 240 8.3 8.20" (208mm) 0.63" (16mm)

029766 2.8kW 240 11.7 8.20" (208mm) 0.63" (16mm)

029767 3.6kW 240 15 8.20" (208mm) 0.63" (16mm)

060418 3.6kW (Two-stage) 240 15 8.63" (219mm) 0.63" (16mm)

Serpentine VI Elements used with housing 057088

Part Max. Max. Max. Length “A” O.D. “B” Number Watts Volts Amps

040291 5kW 240 20.8 10.88" (276mm) 1.25" (32mm)

040292 6kW 240 25 10.88" (276mm) 1.25" (32mm)

061429 6kW (Two-stage) 240 25 10.88" (276mm) 1.25" (32mm)

056548 8kW 240 33.3 10.88" (276mm) 1.25" (32mm)

Accessories

Part Number Description

039739 Serp II base adaptor assembly

042339 Serp VI base adaptor assembly

029485 Serp II TC holder (includes TC)

040299 Serp VI TC holder (includes TC)

039272 “K” type thermocouple probe, 3/16" (4.8mm) O.D.

066823 Closed loop power control, 240V, 30A, 4–20mA

057081 Open loop (manual) power control, 240V, 25A

070429 Digital temperature controller, 1/16 DIN, 4–20mA

Products

Housing Assembly

Page 12: Fremap Osram Sylvania Catalog

Specifications• Air temperatures to 1400˚F

(760˚C)

• For applications requiring high pressure air

• Both ends threaded 3/8", 1/2", 1-1/4", and 2-1/2" NPT

• 304 Stainless Steel housing

• CE compliant

Style A

• Should be used whenever an absolute leak-proof system (up to 150 PSI) is required

• Two high temperature power feedthroughs

• Maximum inlet temperature 900˚F (482˚C)

Style B

• Maximum air pressure 150 PSI, but will have slight air leakage through power wire strands

• 12" (305mm) flexible power wires

• Maximum inlet temperatures 200°F (93˚C)

Tem

per

atu

re ˚

F

Inline Heaters Maximum Performance

Tem

per

atu

re ˚

C

Air Flow in SCFH

1600

1400

1200

1000

800

600

400

200

00 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 3000 4000 5000 6000 7000 8000

871

760

649

538

427

316

204

93.4

0

0 94 189 283 378 472 566 661 755 850 944 1045 1133 1416 1888 2360 2832 3304 3776Air Flow in SLPM

Sepentine VI Maximum Performance

1.6 kW 4.0 kW 6.0 kW18.0 kW

Performance

10 11

Page 13: Fremap Osram Sylvania Catalog

For detailed operating instructions,

visit www.sylvaniaheaters.com

OSRAM SYLVANIA—Air Heaters 131 Portsmouth Avenue, Exeter, NH 03833 USA Tel. 603-772-4331 Fax 603-772-1072

10 11

Heater Size (NPT) Max. Watts Max. Volts Max. Amps Part No., Style A Part No., Style B

3/8" 1.6kW 170 9.4 038821 038822

1/2" 4.0kW 220 18.2 038823 038824

1-1/4" 6.0kW 220 27.3 038825 038826

2-1/2" 18.0kW 240 75.0 (1 ) /44.0 (3 ) N/A 063007

0.84" (21mm)

9.0"(229mm)

1.0"(25mm)

4.3"(109mm)

#10–322-Places

STYLE A

.5" NPTMale

.5" NPTMale

11.3"(287mm)

1.7"(43mm)

1.0"(25mm)

5.0"(127mm)

#10–322-Places

STYLE A

1.25" NPTMale

1.25" NPTMale

10.75"(273mm)

0.7" (17mm)

1.0"(25mm)

4.3"(109mm)

.87" Dia.(22mm)

#10–322-Places

STYLE A

.375" NPTMale

.375" NPTFemale

60˚(typ)STYLE B

.5" NPTFemale

0.84" (21mm)9.5"

(241mm)

2.0"(51mm)1.2" Dia.(30mm)

(2) #14 AWGWire 12" Long(305mm)

1.13"(29mm)

.5" NPTMale

STYLE B

.5" NPTMale

0.7" (17mm)10.6"

(270mm)3/8 NPTFemale

1.3"(33mm)0.95" Dia.(24mm)

(2) #16 AWGWire 12" Long(305mm)

.95"(24mm)

3/8 NPTMale

STYLE B

3/8 NPTMale

#10 AWGWire 12" Long(305mm)

1.8"(46mm)

12.2"(310mm)

1.25" NPTFemale

1.2"(30mm)

2.0"(51mm)

.5" NPTMale

STYLE B

1.25" NPTMale

1.7"(43mm)

12.2"(310mm)

STYLE B

2.1"(54mm)

3/8" THREADED INLINES

1/2" THREADED INLINES

1-1/4" THREADED INLINES

2-1/2" THREADED INLINE

Installation

AccessoriesPart Number Description

057081 Open loop (manual) power control, 240V, 25A

066823 Closed loop power control, 240V, 30A

070429 Temperature controller — 1⁄16 DIN, 4–20mA

039272 “K” Type Thermocouple Probe

Products

Page 14: Fremap Osram Sylvania Catalog

Specifications

• Air temp controllable to 1400°F (760°C) ±1°

• Power 3.0kW - 8.0kW 240V~ 1

• Two internal “K” TC sensors for control and safety: o S1 measures inlet temp. o S2 measures exit temp.

• Rapid heat-up and cool-down.

• Maximum air pressure 60 PSI (4 Bar)

• CE, UL compliant

• ‘Ceramic-only’ design for food packaging applications.

• Max inlet temp 200°F (93°C)

• Use SureHeat JET CONTROL (purchased separately) for easy installation.

12

Performance

Page 15: Fremap Osram Sylvania Catalog

For detailed operating instructions,

visit www.sylvaniaheaters.com

OSRAM SYLVANIA—Air Heaters 131 Portsmouth Avenue, Exeter, NH 03833 USA Tel. 603-772-4331 Fax 603-772-1072

Part Number Description Max Watts Max Volts Max Amps

074722 SureHeat JET CONTROL 8.0kW 240V~ 1 50/60 Hz 35

Accessories

Part Number Description Max Watts Max Volts Max Amps

074718 SureHeat JET 3.0kW Heater 3.0kW 240V~ 1 50/60 Hz 12.5

074719 SureHeat JET 8.0kW Heater 8.0kW 240V~ 1 50/60 Hz 33.3

Products

13

Installation

Wiring Notes:

• S1 and S2 sensors are “K” type thermocouples.

• S1 measures inlet air temperature.

• S2 measures exit air temperature.

• See Operating Manual for control settings.

Page 16: Fremap Osram Sylvania Catalog

Specifications• Air temp controllable to 1400°F (760°C) ±1°

• Power 6.0kW - 36.0kW 240/380/480V~ 1 /3

• Two internal “K” TC sensors for control and safety:

o S1 measures inlet temp.

o S2 measures exit temp.

• Rapid heat-up and cool-down.

• Maximum air pressure 60 PSI (4 Bar)

• CE, UL compliant

• ‘Ceramic-only’ design for food packaging applications.

• Max inlet air temp 200°F (93°C)

14

Performance

Page 17: Fremap Osram Sylvania Catalog

OSRAM SYLVANIA—Air Heaters 131 Portsmouth Avenue, Exeter, NH 03833 USA Tel. 603-772-4331 Fax 603-772-1072

15

Wiring Notes:• S1 and S2 sensors are "K" type thermocouples.• S1 measures inlet air temperature.• S2 measures exit air temperature.• See Operating Manual for control settings.

Installation Notes:• 18kW, 36kW heater is 16" (406.4mm) long.• 6kW, 10k W heater is 12" (304.8mm) long.• Difference is 4" (101.6mm) shorter nozzle tube.

For detailed operating instructions,

visit www.sylvaniaheaters.com

Part Number Description Max Max Volts Max Watts Amps

074723 SureHeat MAX 6.0kW Heater 6.0kW 240V~ 1 50/60 Hz 25.0

074724 SureHeat MAX 6.0kW Heater 6.0kW 240V~ 3 50/60 Hz 14.5

074725 SureHeat MAX 6.0kW Heater 6.0kW 380V~ 3 50/60 Hz 9.1

074726 SureHeat MAX 6.0kW Heater 6.0kW 480V~ 3 50/60 Hz 7.2

074727 SureHeat MAX 10.0kW Heater 10.0kW 240V~ 1 50/60 Hz 41.7

074728 SureHeat MAX 10.0kW Heater 10.0kW 240V~ 3 50/60 Hz 24.1

074729 SureHeat MAX 10.0kW Heater 10.0kW 380V~ 3 50/60 Hz 15.2

074731 SureHeat MAX 10.0kW Heater 10.0kW 480V~ 3 50/60 Hz 12.0

074732 SureHeat MAX 18.0kW Heater 18.0kW 240V~ 3 50/60 Hz 43.4

074733 SureHeat MAX 18.0kW Heater 18.0kW 380V~ 3 50/60 Hz 27.4

074734 SureHeat MAX 18.0kW Heater 18.0kW 480V~ 3 50/60 Hz 21.7

074735 SureHeat MAX 30.0kW Heater 30.0kW 380V~ 3 50/60 Hz 45.6

074736 SureHeat MAX 36.0kW Heater 36.0kW 480V~ 3 50/60 Hz 43.4

Products

Part Number Description

074829 1/16 DIN Digital temperature control (for S2)

074835 Thermal safety switch (for S1)

Accessories

15

Installation

OSRAM SYLVANIA—Air Heaters 131 Portsmouth Avenue, Exeter, NH 03833 USA Tel. 603-772-4331 Fax 603-772-1072

Page 18: Fremap Osram Sylvania Catalog

Exit

Air

Tem

pera

ture

˚F

Flanged Inline Heater Maximum Performance

Air Flow in SCFM

1600

1400

1200

1000

800

600

400

200

00 200 400 600 800 1000

Tem

pera

ture

˚C

871

760

649

538

427

316

204

93.4

36 kW 72 kW144 kW192 kW

Specifications

• Designed for high pressure, high flow applications

• Air/inert gas temperatures to 1400˚F (760˚C)

• Uses SureHeat overtemperature protection system

• Up to 192kW in a compact 2' (610mm) long size

• Maximum air pressure 150 PSI (10 Bar)

• 304 Stainless Steel ASME welded 300 lb. flanged housing

• Maximum inlet temperature 900˚F (482˚C)

• Built-in “K” type thermocouple

Performance

16

Page 19: Fremap Osram Sylvania Catalog

For detailed operating instructions,

visit www.sylvaniaheaters.com

OSRAM SYLVANIA—Air Heaters 131 Portsmouth Avenue, Exeter, NH 03833 USA Tel. 603-772-4331 Fax 603-772-1072

Installation

Heater Part Max. Max. Max. Pipe I.D. Flange O.D. Bolt Circle Replacement SCRNumber* kW Volts Amps “I” “D” “C” Element Power Control # Holes/Dia. Part Number Part Number

073166 36.0 480 - 3Ø 45 4.0" (102mm) 10.0" (254mm) 8-.088”/7.88” 073167 072765

073377 72.0 480 - 3Ø 87 6.0" (152mm) 12.5" (318mm) 12-.088”/10.62” 073378 072764

073384 144.0 480 - 3Ø 175 8.0" (203mm) 15.0" (381mm) 12-1.00”/13.00” 073385 072763

073153 192.0 480 - 3Ø 235 8.0" (203mm) 15.0" (381mm) 12-1.00”/13.00” 073253 072762

*includes elementA complete functional system must have heater, SCR power control, over-temperature board, and digital temperature control.

17

Part Number Description

070429 1/16 DIN digital temperature control, 4–20 mA

073262 Over-temperature control board (required)

039272 Replacement “K” type thermocouple probe

Accessories

Products

Page 20: Fremap Osram Sylvania Catalog

A. Air Heater Energy Requirement

kW = SCFM x (Texit – Tinlet) / 2500

B. Temperature Conversions

°F = 9/5 (°C) + 32°C = 5/9 (°F – 32)

C. Air Flow Conversions

SCFM = SCFH / 60 = SLPM / 28.3SLPM = SCFH / 2.12SCMH = SCFH / 35.3SCFM = (Pounds of Air Per Minute) / (.080 lbs/ft3)

SCFM = Standard Cubic Feet per MinuteSCFH = Standard Cubic Feet per HourSLPM = Standard Liters per MinuteSCMH = Standard Cubic Meters per Hour

18 D. Single Phase Wiring

V = I x R (Volts = Amps x Ohms)I = W / V (Amps = Watts / Volts) W = V2/R (Watts = (Volts x Volts) / Ohms)

E. Three Phase Wiring

Delta Configuration

R = R1 = R2 = R3Wdelta = 3(VL

2)/RWdelta = 1.73 x VL x ILIP = IL/1.73VP = VL

Wye Configuration R = R1 = R2 = R3Wwye = (VL

2)/R = 3(VP2)/R

Wwye = 1.73 x VL x IPIP = ILVP = VL/1.73

Wye Configuration Delta Configuration

Page 21: Fremap Osram Sylvania Catalog

For detailed operating instructions,

visit www.sylvaniaheaters.com

OSRAM SYLVANIA—Air Heaters 131 Portsmouth Avenue, Exeter, NH 03833 USA Tel. 603-772-4331 Fax 603-772-1072

19

Page 22: Fremap Osram Sylvania Catalog

For orders and product information:

OSRAM SYLVANIA131 Portsmouth AvenueExeter, NH 03833 USATel. 800-258-8290In NH 603-772-4331Fax 603-772-1072www.sylvaniaheaters.com

OSRAM SYLVANIAHEADQUARTERS 100 Endicott StreetDanvers, MA 01923(978) 777-1900www.sylvania.com

© 2005 OSRAM SYLVANIA

PMC 007

The information and recommendations contained in this publication are based upon data collected by OSRAM SYLVANIA and believed to be correct. However, no guarantee or warranty of any kind, expressed or implied, is made with respect to the information contained herein, and OSRAM SYLVANIA assumes no responsibility for the results of the use of products and processes described herein. No statements or recommendations made herein are to be construed as inducements to infringe any relevant patent, now or hereafter in existence.