  • FLETA 40 USER MAUAL

    1. General description 1-1. Components --------------------- 2 1-2. Operation & keeping condition 2. Installation 2-1. Safety ------------------------------------3 2-2. Location of Installation -----------------4 2-3. Check list --------------------------------5 2-4. Power Supply ---------------------------6 3. Operation 3-1. Feature ----------------------------------7 3-2. Structure 3-3. Rotor-------------------------------------8 3-4. Function --------------------------------11 3-5. Operating 4. Washing & Maintenance 4-1. Washing---------------------------------14 4-2. Maintenance ---------------------------16 5. Trouble shooting 5-1. Warning Lamp ----------------------------17 6. Rotor & Accessory 6-1. Rotor specification ----------------------18

  • 1. General Description

    FLETA 40 is Multipurpose Centrifuge, this manual is for a starter, which offers the information of trouble shooting, maintenance, precautionary measure and usage. Operator must read this manual for the successful handling of every function and this manual should be placed at the easy accessible location. All instructions described on this manual is for safe operation, therefore You must read in advance to the actual operation. 1-1. Components

    Item Q’nty

    Main-body 1 Power cable 1 User Manual 1 Hexagonal T wrench (5mm) 1 Packing check list 1) Check thoroughly the status of the packing upon the arrival. 2) Immediately notify the detail in the case of the damage 3) The contact channel is on the packing and the user manual

    1-2 The condition of keeping & operation -Operation Room temp 5~35℃, max relative humidity 30~50%, Air pressure 500~1,000 hpa -Keeping The ambient temp -10~+40℃, max humidity 10~90% Air pressure 500~1.060 hpa

  • 2. Installation 2-1. Safety Centrifuge containing the high speed rotating part is dangerous. Follow the instruction described in this manual to avoid breakage, trouble, injury. 1) Centrifuge must be placed the horizontally flat level, In the case of tilted

    shaft of rotating big vibration occurs. 2) Check the voltage before connecting power, the improper volt may cause the

    damage. 3) Use only the rotor, parts and accessories supplied by the maker, which is

    not responsible for any damage caused by improper parts not recommended by the maker.

    4) Ascertain the material property completely and pre-arrange safety measure in the case of handling pathogenic, toxic, radioactive material.

    5) As Centrifuge is contaminated by pathogenic, toxic, radioactive material, contaminant is to be cleared and ventilated and the isolation is needed.

    6) Volatile and explosive material should not be treated by Centrifuge. 7) Don’t operate over the approved maximum rpm of rotor. 8) Don’t diminish and stop the rotating rotor with hand. 9) Rotor must be operated after symmetrical balance work of weight 10) Rotor must be fixed to the rotating shaft exactly and lid also fixed completely. If not,

    the lid may open during operation. 11) Repairing and maintenance not mentioned on this manual must be

    handled by the technician with the proper curriculum (in this case the contaminant is to be cleared)

    12) In order to keep the best condition and operation of long term the chamber of rotor must be kept dry.

    13) The chemical corrosion of rotor contacting strong acid, alkaline agent of Cesium, silver, chlorine base should be avoided carefully.

  • 2-2. Location of placement To be installed on the rigid and flat level; The rotation of heavy rotor in the long period on the inclined level may cause the deformation of rotating shaft. Smooth air ventilation; Centrifuge needs 30cm of vacant space of front & rear and right & left. An airway should not be covered by the another instrument or fabric, avoid the place of heavy dust. Constant temp. & humidity; The sensitive electronic controller is affected by ambient temp. and humidity. Avoid direct sunray and heater and keep the constant temp. & humidity. No erosive gas; Avoid the place of erosive gas. Contacting sulfurous acid/ chlorine gas erodes Rotor & shaft and damage metal parts. Leveling; Shaft should be vertical exactly and Centrifuge is to be placed horizontally with flatness measuring device.

  • 2-3. Check list Don’t open door manually during rotating rotor, don’t use emergency door open device except the emergent case. Rotating speed of rotor should not exceed the allowed max speed. The rotor is designed to endure only with the allowed influencing power. If RCF exceeds the allowed tensile strength, the rotor shall break or be deformed. Circuit breaker; Lightning or over voltage activates circuit breaker, cut off fuse and power supply to protect main body. Door lock device; Door sensor lets rotor stop in the case of open door and Centrifuge doesn’t operate at the status of door open. Auto door lock device doesn’t allow door open during operation without manual opening of door. Abnormal vibration; As rotating rotor vibrates seriously over the limited standard off balance and Accordingly motor shakes, the relevant sensor detects the abnormality and the rotation stops according to the pre-arranged deceleration interval. This safety device avoid the unexpected danger & damage during operater’s absence with the continuous operation of Centrifuge.

  • 2-4. Electrical requirements Ascertain the rated voltage on the label of Centrifuge. Unclear power supply of using should be checked again with the local electric power supplier or our A/S center. Warning ; Centrifuge must connect to ground. -Centrifuge contains plug with earth pin which can be inserted into the grounded receptacle. Using receptacle without earth must be replaced to grounded receptacle, during this work user must be careful not to get electric shock with the assistance of electrician. Avoid the receptacle without grounding. -In the case of error the emergency switch is located at the exit door side or outside of laboratory, a remote area from Centrifuge to cut off power supply.

    -The safety distance 30 cm from Centrifuge must be kept and any breakable unit is moved away according to IEC61010-2-020 regulation. Electric safety ° The power cord offered with Centrifuge is used only. ° Connect power supply. ° Don’t use the extended power code. Checking out grounded receptacle is to be done by electrician.

    ° Failure of earth work may cause the electric shock. ° Another instrument should not step on the power code. ° Ventilation hole should not be covered by any material. ° Switch off power supply, pull off power code from receptacle, contact A/S center in the

    below cases. -Abnormal noise or smell -Worn out or damaged power code - Cut off wall mounted circuit breaker, fuse, another safety devices - Spilt over liquid or water on Centrifuge - Damaged part

  • 3. Checking Opeaon 3-1. Feature

    3-2. Structure ① Door; to protect the internal chamber and erupting rotor ② Locking hook ③ Peeping hole; to check rpm by the digital speed meter ④ Chamber ⑤ Door packing; ⑥ Rotor ⑦ Control board ⑧ On/off switch ⑨ Emergency door open device; manually open door on power failure, etc.

  • 2) Internal structure of chamber ① Chamber; to protect erupting rotor ② Motor cover; intruding foreign substance into motor ③ Motor shaft

    Don’t grab the edge side of door to avoid any possible injury. Put hands on the door cover and press and check the complete closing to Operate

  • 3-3 Rotor

    - Wipe the motor shaft and hole of rotor with fabric before installation

    - As tighten rotor with motor shaft, temp. of rotor & motor should be 10~30℃

    - Put rotor on the motor shaft tighten clockwise with hexagonal wrench In the case of release screw wrench to the counter direction

    1) Weight loading on rotor - Put tubes symmetrically on rotor, only recommended tubes are workable.

    - The weight difference between sample tubes must be minimized to diminish noise and extend durability

    - Locate tubes of same type for the stability of Centrifuge -

    * Use only rotor/tube/adapter recommended by the manufacturer * Check the proper tube-rack insert and smooth motion * Don’t use the eroded motor of visibly mechanical failure 2) Tube arrangement

    Same volume of sample must be put in tubes after precise measuring and arrange the symmetrical insert to rotor. In the case of difference per each symmetrically arranged samples heavy vibration occurs, which may damage the shaft. Despite the same q’nty of tubes the location of tubes may be dissymmetrical. Adapters’ tube location facing each other also must be checked the proper location. In the case of dissymmetrical location caused by the variation of tube q’nty newly added tube may make the equilibrium. Use a scale to minimize the weight difference of sample tubes.

    In the case of spin down lean tubes’ lids against the edge of rotor and

  • Ascertain the sameness of tubes and close the rotor lid. This instruction must be applicable for using tubes provided by the kit manufacturer.

    Swing bucket rotor

    Check the internal cleanness of bucket and wipe out the foreign material with dry fabric. In the case of two buckets check the hanging status on rotor and do swing test manually. Rotor must be inserted with the symmetrical location of adapter, plate, tubes. In the case of different weight of sample of symmetrically located the heavy vibration by unbalance rotation may result in the damage of rotor & shaft.

  • Safety label

    Danger & alarm

    Danger of electric shock

    Warning! The dissymmetrical placement of rotor causes injury Check rotor connection, rotor closing tubes’ location carefully before start -Place tubes of same type symmetrically

    -Use the adequate tubes with adapter -Use always homogeneous tube (same Weight, material property, dendity,

    Volume)

    Warning

    Loads must be located symmetrically shock

    Warning Don’t impact during rotation. ,

  • 3-4. Function check Test maximum speed of rotor. Check whether Centrifuge works at the door opened situation and door may open during operation. 3-5. Operation detail 1) Control panel description

  • 2) Save and call program

    3) Call/input program

    4) Input RPM/RCF

    5) Input Time

    6) Short Run mode

  • 7) Simulation Set value of simulation; SL50-4(No.1), 4,000 RPM, 3 min is set in PROG No.3.

  • 4. Wash & Maintenance

    Emergency open Activate the emergency door open device manually in the case of power failure.

    1) Off power switch, await till rotor stops.

    2) Insert 5mm T wrench into the hole on the right flank side and turn clockwise to open door.

    4-1. Cleaning 1) Exterior

    - Clean the surface with soft & dry fabric. In the case of heavy contamination wipe out with soft soapy cloth and use dry cloth to remove water.

    - Don’t use chemicals like alcohol, benzene, thinner which may damage Centrifuge. Use neutral detergent of sound quality.

    - Don’t make any scratch with hard & sharp material like metal brush and move cautiously to avoid rust.

    - Remove rust from humidity for long period with the netural detergent and wipe out with dry fabric.

  • 2) Interior - Remove and clean periodically frost of rotor & chamber for the efficient

    cooling.

    - Off power switch and remove frost with dry cloth - Clean the chamber with soaked sponge or cloth and dry completely after

    removing frost. 3) Shaft

    - Shaft must be kept clean, the unstable rotation by contaminant of shaft causes imbalance.

    - Take rotor out of shaft and clean with dry fabric to remove water after operation and keep dry.

    - Weight of rotor causes deformation of shaft, which must be separated and cleaned and kept upside down.

    - As rotor tightly sticks with shaft, don’t remove forcibly, only use the specialized rotor removing tool.

    4) Rotor ① Corrosion & surface treatment

    - Acid or basic agent causes damage. Imbalance of rotor weight by corrosion incurs heavy vibration & noise, eventually the physical damage.

    - Anti-corrosive rotor may be affected by humidity, salt content and impurity in air.

    - Rotor is resistant to neutral aqueous solution like carbonate, chromate, acetate and sulfide, but not to chloride agent. Also corrosion gets faster By increase of hydrogen ion content and eroded by sulfuric and phosphoric and faster in hydraulic acid.

    ② Maintenance

    - Cleaning; remove sample in tube with soft fabric soaked with warm water avoid scratch on the specially treated rotor surface.

    - Drying; dry narrow groove of rotor, more efficiently with hair-drier. - Keeping; Clean & dry place, separate lid of angle and keep upside down. ③ Sterilization of rotor Every rotor, lid, bucket adapter can be sterilized at 121℃ for 20 min.

  • 4-2. Maintenance 1) Check & clean rotor frequently 2) General check points

    Shaft & hub; Don’t separate hub and bent shaft, check abrasion. Motor bearing; Check noise and the smooth rotation Control board; Check bolt connection and functioning Power supply; Check whether connection is loosened. Rotor; Check crack, cleanness, abrasion.

    3) RPM Install rotor and set RPM, count the actual RPM with tachometer.

    4) Time Set 10 min and count the actual time with stop watch.

    5) Detecting Imbalance In the case of imbalanced rotor, check whether the lamp of imbalance is on with alarm sound.

    6) Door locking device Door should not open during operation.

    7) Disposal Centrifuge should not be scraped as the waste of house hold and only disposed according to the local environmental regulation.

  • 5. Trouble shooting 5-1. Warning Signal

  • 6-1 Rotor Specification

    Capacity Rotor Name

    Rotor No.

    Max. RPM

    Max. RCF

    Max. Radius(mm)

    Swing Rotor

    85 ml SL 85-4 1 4,000 3,088 172.6

    50 ml SL 50-6 2 4,000 3,088 172.6

    Angle Rotor

    15 ml AL15-12 3 4,000 2,547 142.4

    15 ml AL 15-24 4 4,000 2,789 155.9

  • NO.3

    Type : Max. RPM : Max. RCF : Radius : Dim. Ø/H :

    15(16) 15ml

    18 x 100 17 x 120

    Tube per Rotor 12 122,547 2,547

    142.4 142.4

    18x104.5 18x104.5

    - -

    - -

    18x125 18x125

    Fleta-40

    4,000

    2,547

    Angle Rotor ∠45°

    4,000 rpm

    2,547x g

    142.4 mm

    Ø285.9 x 88.9 mm

    AL15 - 12

    Tube Capacity (ml)Dimensions Øx L mm

    Tube Type

    Adapter - -

    Max.RCFradius (mm)boring Ø x L mmColor / Material

    Cat.NO.Max. length Ø x L

    Rotor for CentrifugesModel

    MAX. RPM

    MAX. RCF

  • NO.4

    Type : Max. RPM : Max. RCF : Radius : Dim. Ø/H :

    15(16) 15

    18 x 100 17 x 120

    Tube per Rotor 24 242,789 2,789

    155.8 155.8

    18x104.5 18x104.5

    - -

    18x125 18x125

    Fleta-40

    4,000

    2,789

    Angle Rotor ∠45°

    4,000 rpm

    2,789x g

    155.9mm

    Ø312.6 x 103.3 mm

    AL15 - 24

    Tube Capacity (ml)Dimensions Øx L mm

    Tube Type

    Adapter - -

    Max.RCFradius (mm)boring Ø x L mmColor / MaterialCat.NO.Max. length Ø x L

    Rotor for CentrifugesModel

    MAX. RPM

    MAX. RCF

  • NO.1

    Type : Swing Rotor ∠90° Max. RPM : 4,000 rpm Max. RCF : 3,088 x g Radius : 172.6 mm Dim. Ø/H : Ø230 x 29mm

    15(16) 50

    18x99.3 28.8 x 106.7

    1 1

    4 4

    18 x 93.5 30x93.5

    White White

    - -

    18 x 145 30x145

    SL85 - 4

    Tube Capacity (ml) 85Dimensions Øx L mm 38 x 106

    Tube Type

    Adapter

    Tube per Adapter -Tube per Rotor 4Max.RCF 3,088radius (mm) / rpm 172.6 / 4,000boring Ø x L mm 38.5x93.5Color / Material -Cat.NO. -

    Rotor for Centrifuges Fleta-40P

    Max. length Ø x L 38.5x145

  • Part List> Hanil Science Industrial Product_FLETA-40

    Item Name SPEC. Quantity Note

    1 Main Case 448.5x531x215 1

    2 Door Assembly 416.7x427.8x35 1

    3 Door Packing Φ440x39 1

    4 Motor Cover Φ150x35 1

    5 Hexagon Bolt M5x20 4

    6 Round headed Bolt(+) M3x15 3

    7 Botton Plate 436.3x519.1x212 1

    8 Cross recess Bolt(+) M4x15 9

    9 Cross recess Bolt(+) M5x15 4

    ABS

    N/A

    Silicone

    ABS

    SUS304

    SUS304

    SPCC

    SUS304

    SUS304

  • 10 Main Board 165x113 1N/A

    11 Support Fixture M3xL7 4Bs

    12 Round headed Bolt(+) M3x5 4Steel

    13 Round headed Bolt(+) M3x10 3Steel

    Part List> Hanil Science Industrial Product_FLETA-40

    Item Name SPEC. Quantity Note

    1 Main Case 448.5x531x215 1

    2 Door Assembly 416.7x427.8x35 1

    3 Door Packing Φ440x39 1

    4 Motor Cover Φ150x35 1

    5 Hexagon Bolt M5x20 4

    6 Round headed Bolt(+) M3x15 3

    7 Botton Plate 436.3x519.1x212 1

    8 Cross recess Bolt(+) M4x15 9

    9 Cross recess Bolt(+) M5x15 4

    ABS

    N/A

    Silicone

    ABS

    SUS304

    SUS304

    SPCC

    SUS304

    SUS304

  • Part List> Hanil Science Industrial Product_FLETA-40

    Item Name SPEC. Quantity Note

    1 Door Plate 405x417x25 1

    2 Hinge 33 x 38.8 x 38 2

    3 Hinge Spring(Left) 선경:Φ2.5 내경:?12 1

    4 Hinge Spring(Right) 선경:Φ2.5 내경:?12 1

    5 Hinge Bushing Φ11.9x33 2

    6 Flat Washer M8 2

    7 Spring Washer M8 2

    8 Hexagon Nut M8 2

    9 Hexagon Bolt M8x75 2

    SPCC

    AL6063

    SWP

    ABS

    Bs

    SUS304

    SUS304

    SUS304

    SUS304

    10 Spring Bushing Φ11x24 2Bs

    11 Lock Loop 50x26x43xt4.0 2SUS304

    12 Hexagon Nut M4 6SUS304

  • Part List> Hanil Science Industrial Product_FLETA-40

    Item Name SPEC. Quantity Note

    1 Bottom Plate 436.3x519.1x212 1

    2 Latch 268x36.5x52.8xt3.0 1

    3 DC Geared Motor KGF-3429B(24VDC) 1

    4 Spur Gear Φ33.6x14 1

    5 Emergency Bushing Φ15x54 1

    6 Latch Bolt Φ13x27.5 2

    7 Micro Bar Switch SS-J5GL-P 3

    8 Hexagon Nut M5 2

    9 Round headed Bolt(+) M3x10 6

    SPCC

    SPCC

    N/A

    AL2024

    SUM22

    SM45C

    N/A

    SUS304

    SUS304

    10 Flat headed Bolt(+) M4x8 4SUS304

    11 Headless Bolt 50x26x43xt4.0 4SUS304

    12 Flat Washer M4 2SUS304

    1:100

  • ABS

    N/A

    PC

    Steel

    Part List> Hanil Science Industrial Product_FLETA-40

    Item Name SPEC. Quantity Note

    1 Main Case 448.5x531x215 1

    2 Display Board 233x70 1

    3 Membrane 292.4x82.7 1

    4 Round headed Bolt(+) M3x6 8