MATERIALS OF CONSTRUCTION
1. NORMAL WEIGHT CONCRETEGENERAL STRUCTURAL CONCRETE f'c = 3,500 psi
2. REINFORCING STEEL - ASTM A615 GRADE 60 Fy = 60 ksiWELDED WIRE REINFORCEMENT - ASTM A1064 Fy = 70 ksi
3. STRUCTURAL STEELANGLES - ASTM A36 Fy = 36 ksiPLATES - ASTM A36 Fy = 36 ksiWELDING ELECTRODES - E70XX LOW HYDROGENGENERAL CONSTRUCTION NOTES
1. STRUCTURAL DRAWINGS SHOULD NOT BE SCALED. PRINTED DIMENSIONS HAVE PRECEDENCE OVER SCALED DRAWINGS AND LARGE SCALE OVER SMALL.
2. EXISTING BUILDING INFORMATION TAKEN FROM THE FOLLOWING ORIGINAL DESIGN DOCUMENTS: NEIGHBORHOOD RECREATION FACILITY FOR THE CITY OF HOPEWELL, 12 DECEMBER 1978.
3. ALL DRAWINGS AND SPECIFICATIONS ARE CONSIDERED TO BE A PART OF THE CONTRACT DOCUMENTS.
4. THE GC SHALL VISIT THE SITE AND GET FAMILIAR WITH EXISTING CONDITIONS, CHECK AND VERIFY EXISTING DIMENSIONS AND TAKE ADDITIONAL MEASUREMENTS AS NEEDED. NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN ACTUAL CONDITIONS AND INDICATED CONDITIONS. MODIFICATION OF DETAILS OF CONSTRUCTION SHALL NOT BE MADE WITHOUT WRITTEN APPROVAL OF THE ENGINEER.
5. GC SHALL PROVIDE AND BE RESPONSIBLE FOR THE PROTECTION AND REPAIR OF ADJACENT EXISTING SURFACES AND AREAS WHICH MAY BE DAMAGED BY NEW WORK.
6. TYPICAL DETAILS SHALL APPLY IN GENERAL CONSTRUCTION UNLESS SPECIFICALLY DETAILED. WHERE NO DETAILS ARE GIVEN, CONSTRUCTION SHALL BE AS SHOWN FOR SIMILAR WORK.
7. THE GC SHALL BE RESPONSIBLE FOR ADEQUATE DESIGN AND CONSTRUCTION OF ALL FORMS, SHORING AND TEMPORARY BRACING. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE AND SAFETY OF WORKERS DURING CONSTRUCTION.
A. DO NOT PLACE CONSTRUCTION MATERIALS OR OTHER CONSTRUCTION LOADS ON THE STRUCTURE SUCH THAT THE LOADS PLACED EXCEED THE CAPACITY OF THE STRUCTURE.
B. PROVIDE TEMPORARY BRACING AND SHORING TO PROVIDE STABILITY AND RESIST ALL LOADS TO WHICH THE PARTIALLY REPAIRED STRUCTURE MAY BE SUBJECTED. ADEQUACY OF TEMPORARY BRACING AND SHORING FOR THIS PURPOSE IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
CONCRETE AND REINFORCING
1. LOCATION OF CONSTRUCTION JOINTS OR POUR JOINTS SHALL BE AS INDICATED ON APPROVED SHOP DRAWINGS.
2. ALL CONCRETE SHALL BE VIBRATED DURING PLACEMENT.
3. NO STAKES, STEEL OR WOOD, SHALL BE PERMITTED IN ANY CONCRETE POUR. SUSPEND FORMS FROM ABOVE GRADE.
4. ANCHOR RODS, DOWELS, REINFORCING STEEL, INSERTS, ETC, SHALL BE SECURELY TIED IN PLACE PRIOR TO POURING CONCRETE. CONCRETE BLOCKS ONLY SHALL BE USED TO SUPPORT REINFORCING OFF GRADE.
5. ALL REINFORCEMENT SHALL BE DETAILED, FABRICATED AND PLACED IN ACCORDANCE WITH ACI 315.
6. REINFORCING BAR DOWELS, REINFORCING BARS, THREADED RODS, BOLTS, ETC WHICH ARE INDICATED AS ADHESIVE ANCHOR OR ADHESIVE DOWELS INTO CONCRETE SHALL BE ACCOMPLISHED USING HILTI HIT HY-200 (ICC ESR 3187) OR AN APPROVED EQUAL. INSTALL IN ACCORDANCE WITH MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS. ADHESIVE ANCHORS AND DOWELS SHALL BE INSTALLED BY ACI CERTIFIED INSTALLERS.
STRUCTURAL STEEL
1. ALL WELDERS MUST BE AWS CERTIFIED AND QUALIFIED IN THE PROCESS USED.
2. WELD LENGTHS CALLED FOR ON THE PLANS ARE THE NET EFFECTIVE LENGTH REQUIRED. WHERE FILLET WELD SYMBOL IS GIVEN WITHOUT INDICATION OF SIZE, USE 3/16" MINIMUM SIZE.
3. E70XX ELECTRODES SHALL BE USED FOR ALL WELDING. THE WELDING OF E7018 OVER E70TG-K2 IS NOT ALLOWED. THE MIXING OF ANY OTHER PROCESSES AND WIRES MUST BE SUBMITTED TO THE STRUCTURAL ENGINEER OF RECORD FOR APPROVAL. THE USE OF E70-T4 IS NOT ALLOWED. IN GROOVE WELDS, FCAW FILLER METAL WIRE SHALL BE LIMITED TO 5/64" DIAMETER. SMAW WELDING ELECTRODES SHALL BE LIMITED TO 5/32" DIAMETER.
4. ALL SHOP AND FIELD WELDS SHALL BE PREQUALIFIED WELDS.
5. A WELDING PROCEDURE SPECIFICATION (WPS) PER AWS D1.1 SHALL BE DEVELOPED BY THE FABRICATOR/ERECTOR AND APPROVED BY THE STRUCTURAL ENGINEER OR THEIR DESIGNEE. THE WPS SHALL INCLUDE THE WELDING PARAMETERS RECOMMENDED BY THE ELECTRODE MANUFACTURER. THE WPS MUST BE SUBMITTED AND APPROVED BEFORE ANY WELDING MAY BEGIN. ALLOW A MINIMUM OF FOUR WEEKS FOR THE REVIEW PROCESS.
SCOPE OF WORK
THE PROJECT SCOPE OF WORK INCLUDES, BUT NOT LIMITED TO, THE FOLLOWING:
1. RELOCATION OF ANY EXISTING FACILITY EQUIPMENT AND MECHANICAL, ELECTRICAL, PLUMBING (MEP) ELEMENTS ADJACENT TO CORRODING STRUCTURAL STEEL COLUMNS, AS REQUIRED, TO COMPLETE REPAIR WORK.
2. REMOVAL OF SLAB ON GRADE AROUND CORRODING STRUCTURAL STEEL COLUMNS TO COMPLETE REPAIR WORK.
3. REPAIR OF CORRODING STRUCTURAL STEEL COLUMNS.4. PLACEMENT OF ANY NEW CONCRETE SLABS ON GRADE, AND APPLY COATINGS PER
SPECIFICATIONS
SEQUENCING OF WORK
COLUMNS INDICATED TO REQUIRE REINFORCEMENT AND COATING:1. COORDINATE REMOVAL OF EXISTING PIPING SERVING EXISTING BASEBOARD HEATERS TO THE
EXTENT SHOWN ON SHEET S-4. ONCE WORK BY OTHER TRADES IS COMPLETED, REPLACE REMOVED PIPING AND FITTINGS WITH NEW. MATERIAL TYPE AND METHOD OF CONNECTION TO MATCH EXISTING.
2. PRIOR TO REMOVAL OF PIPING, CONFIRM SYSTEM HAS BEEN PROPERLY DRAINED DOWN.3. INSTALL TEMPORARY SHORING IF DEEMED NECESSARY BY THE GC. SHORING DESIGN AND
CONSTRUCTION IS THE SOLE RESPONSIBILITY OF THE GC.4. DEMOLISH POOL DECK SLAB ON GRADE AROUND STEEL COLUMNS. EXPOSE COLUMNS TO THE
TOP OF BASEPLATE. REMOVE ALL DELETERIOUS MATERIALS AROUND THE STEEL.5. REMOVE EXISTING SURFACE COATING, CORROSION AND MISCELLANEOUS ATTACHMENTS FROM
STEEL COLUMNS TO A MINIMUM HEIGHT OF 18" ABOVE FINISHED FLOOR. PREPARE SIDES OF COLUMN EXPOSED TO POOL DECK EXTENDING TO THE BASEPLATE ACCORDING TO SPECIFICATIONS .
6. WELD NEW STEEL REINFORCEMENT TO COLUMNS. 7. COAT STEEL WITH PAINT AS INDICATED ON THE SPECIFICATIONS..8. BACKFILL AND COMPACT SUBGRADE. INFILL WITH NEW SLAB ON GRADE.9. APPLY PAINT SYSTEM TO CONCRETE FLOOR PER SPECIFICATIONS.10. RECONNECT PIPING SERVING BASEBOARD HEATERS. REFILL THE SYSTEM UTILIZING EXISTING
VENTS TO PROPERLY PURGE AIR FROM SYSTEM. CONFIRM WITH FACILITY THAT HEATING FLUID IS WATER ONLY; IF GLYCOL IS REQUIRED, CHARGE SYSTEM AS NEEDED TO ATTAIN PROPER CONCENTRATION OR COORDINATE THIS TASK WITH FACILITY-APPROVED VENDOR.
11. REINSTALL FRONT PIPE COVERS USING STAINLESS STEEL SCREWS AND PLASTIC SPACERS.
COLUMNS INDICATED TO REQUIRE COATING ONLY:1. COORDINATE REMOVAL OF EXISTING PIPING SERVING EXISTING BASEBOARD HEATERS TO THE
EXTENT SHOWN ON SHEET S-4. ONCE WORK BY OTHER TRADES IS COMPLETED, REPLACE REMOVED PIPING AND FITTINGS WITH NEW. MATERIAL TYPE AND METHOD OF CONNECTION TO MATCH EXISTING.
2. PRIOR TO REMOVAL OF PIPING, CONFIRM SYSTEM HAS BEEN PROPERLY DRAINED DOWN.3. REMOVE EXISTING SURFACE COATING, CORROSION AND MISCELLANEOUS ATTACHMENTS FROM
STEEL COLUMNS TO A MINIMUM HEIGHT OF 18" ABOVE THE FINISHED FLOOR. PREPARE SIDES OF COLUMN EXPOSED TO POOL DECK ACCORDING TO SPECIFICATIONS .
4. WHERE STEP 1 REVEALS ANY THROUGH-THICKNESS COLUMN DAMAGE, NOTIFY OWNER AND STRUCTURAL ENGINEER.
5. COAT STEEL WITH PAINT AS INDICATED ON THE SPECIFICATIONS.6. RECONNECT PIPING SERVING BASEBOARD HEATERS. REFILL THE SYSTEM UTILIZING EXISTING
VENTS TO PROPERLY PURGE AIR FROM SYSTEM. CONFIRM WITH FACILITY THAT HEATING FLUID IS WATER ONLY; IF GLYCOL IS REQUIRED, CHARGE SYSTEM AS NEEDED TO ATTAIN PROPER CONCENTRATION OR COORDINATE THIS TASK WITH FACILITY-APPROVED VENDOR.
7. REINSTALL FRONT PIPE COVERS USING STAINLESS STEEL SCREWS AND PLASTIC SPACERS.
APPLICABLE CODES AND STANDARDS
1. 2018 VIRGINIA EXISTING BUILDING CODE (VEBC)2. 2018 VIRGINIA CONSTRUCTION CODE (VCC)3. AMERICAN CONCRETE INSTITUTE (ACI): BUILDING CODE REQUIREMENTS
FOR STRUCTURAL CONCRETE (ACI 318-14)4. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC): SPECIFICATION
FOR STRUCTURAL STEEL BUILDINGS (AISC 360-16) AND STEEL CONSTRUCTION MANUAL, 15TH EDITION.
5. AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE): MINIMUM DESIGN LOADS AND ASSOCIATED CRITERIA FOR BUILDINGS AND OTHER STRUCTURES (ASCE 7-16)
6. ASTM MATERIAL STANDARDS NOTED7. AMERICAN WELDING SOCIETY (AWS): STRUCTURAL WELDING CODE - STEEL
(D1.1-2015)
DESIGN LOADS
1. DEAD LOADACTUAL WEIGHT OF MATERIALS USED AND THE FOLLOWING ALLOWANCES:CEILINGS, LIGHTING, MEP 10 psfALLOWANCE FOR ROOFING SYSTEM 20 psf
2. LIVE LOADSLAB ON GRADE 150 psf
3. ROOF LIVE LOADROOF 20 psf
4. SNOW LOAD DATASNOW LOAD 20 psf
5. WIND DESIGN DATAULTIMATE DESIGN WIND SPEED, Vult 113 mphNOMINAL DESIGN WIND SPEED, Vasd 88 mphRISK CATEGORY IIWIND EXPOSURE CATEGORY CINTERNAL PRESSURE COEFFICIENT ±0.18EXISTING BUILDING: DAMAGE TO THE EXISTING STRUCTURAL COLUMNS DUE TO CORROSION IS DEEMED TO BE LESS THAN SUBSTANTIAL STRUCTURAL DAMAGE IN ACCORDANCE WITH VEBC. NO UPGRADE TO THE EXISTING LATERAL FORCE RESISTING SYSTEM IS REQUIRED.
6. EARTHQUAKE DESIGN DATARISK CATEGORY IISEISMIC IMPORTANCE FACTOR, Ie 1.0SITE CLASS DDESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS
Sds 0.18 gSd1 0.08 g
SEISMIC DESIGN CATEGORY BEXISTING BUILDING: DAMAGE TO THE EXISTING STRUCTURAL COLUMNS DUE TO CORROSION IS DEEMED TO BE LESS THAN SUBSTANTIAL STRUCTURAL DAMAGE IN ACCORDANCE WITH VEBC. NO UPGRADE TO THE EXISTING LATERAL FORCE RESISTING SYSTEM IS REQUIRED.
ISSUE DESCRIPTION
FILENAME
SCALE
SHEET
PROJECT NUMBER
BRIAN MELI
COMMUNITY CENTER POOLSTRUCTURAL COLUMN REPAIRS
FINAL DESIGN (100%)
$D
GN
$
DATE
DESIGN PROJECT MANAGER
As indicated
TITLE SHEET
S-1
10311347
CONSTRUCTION MANAGER
CITY ENGINEER
DIRECTOR, RECREATION AND PARKS
DATE
DATE
DATE
APPROVED BY THE CITY OF HOPEWELL
ENGINEER: HDR ENGINEERING INC. OF VIENNA, VA.PRIMARY: BRIAN MELI, PE PHONE: (571) 363-9346EMAIL: [email protected]
CONTACTS
FINAL DESIGN
COMMUNITY CENTER POOL
STRUCTURAL COLUMN REPAIRS100 W. CITY POINT RD.
CITY OF HOPEWELL, VA 23860
GENERAL CONDITIONS
THE GENERAL CONTRACTOR (GC) SHALL PROVIDE ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, UTILITIES, INSURANCE, TRANSPORTATION, AND PAY FOR ALL REQUIRED TAXES, PERMITS, AND SERVICES REQUIRED TO COMPLETE THE ENTIRE SCOPE OF WORK, WHETHER TEMPORARY OR PERMANENT. ALL MATERIALS EXCEPT TEMPORARY FORMS ARE TO BE NEW, UNUSED AND OF THE SPECIFIED QUALITY. THE GC SHALL MAINTAIN THE PROJECT SITE IN A CLEAN AND ORDERLY FASHION. TOOLS AND EQUIPMENT SHALL BE SECURED, AND ALL DEBRIS SHALL BE REMOVED DAILY. THE GC SHALL MAINTAIN A VISITORS LOG. ALL VISITORS SHALL BE REQUIRED TO SIGN SUCH LOG. DATES AND TIMES OF ENTERING ANDEXITING THE SITE FOR ALL VISITORS SHALL BE NOTED. GC TO SECURE PROJECT SITE FROM UNAUTHORIZED ENTRY AT ALL TIMES. COORDINATE LOCATION OF BARRICADES OR TEMPORARY FENCING WITH OWNER.
CONSTRUCTION PROCEDURES
THE GC SHALL SUPERVISE AND DIRECT THE WORK, USING THE CONTRACTOR'S BEST SKILL AND ATTENTION. THE GC SHALL BE SOLELY RESPONSIBLE FOR AND HAVE CONTROL OVER CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF WORK UNDER THE CONTRACT, UNLESS CONTRACT DOCUMENTS GIVE OTHER SPECIFIC INSTRUCTIONS CONCERNING THESE MATTERS. ANY WORK THAT MUST BE REMOVED OR RELOCATED DUE TO LACK OF COORDINATION OF THE TRADES IS SOLELY THE GC'S RESPONSIBILITY. THE CONTRACTOR SHALL MAINTAIN A SECURE SITE THROUGHOUT THE CONSTRUCTION PROCESS.
GOVERNING AGENCIES
THE GC AND ALL OF THEIR FORCES SHALL COMPLY WITH ALL REGULATIONS BY ANY GOVERNING AGENCY WITH JURISDICTION OVER THE PROJECT OR PROJECT SITE.
TOXIC MATERIAL
IN THE EVENT THE GC ENCOUNTERS ON THE SITE MATERIAL REASONABLY BELIEVED TO BE ASBESTOS, POLYCHLORINATED BIPHENYL (PCB) OR OTHER TOXIC MATERIAL, WHICH HAS NOT BEEN RENDERED HARMLESS, THE CONTRACTOR SHALL IMMEDIATELY STOP WORK IN THE AREA AFFECTED, SEAL OFF THE PERIMETER, AND REPORT THE CONDITION TO THE OWNER AND ARCHITECT IN WRITING. NO NEW BUILDING MATERIAL SHALL CONTAIN ASBESTOS, POLYCHLORINATED BIPHENYL (PCB) OR OTHER TOXIC MATERIAL AS DEFINED BY STATE AND FEDERAL REGULATORY AGENCIES.
PROTECTION OF FLOOR SURFACES
GC SHALL PROVIDE ADEQUATE PROTECTION FOR ALL FINISHED FLOOR SURFACES, EXISTING OR NEW INCLUDING BUT NOT LIMITED TO, CERAMIC TILE, VINYL TILE, CONCRETE, ACRYLIC DECK COATING, ETC., THROUGHOUT THE CONSTRUCTION PERIOD. FOR WORK IN THE POOL AREA, THE GCSHALL ENSURE THAT NO DUST, DEBRIS, CHEMICALS, OR OTHER CONSTRUCTION RELATED SUBSTANCES OR MATERIALS ENTER THE POOL WATER OR THE POOL FILTRATION SYSTEM.
PROTECTION OF EXISTING TO REMAIN
THE GC SHALL PROVIDE PROTECTIVE COVERING FOR CARPET, FURNISHINGS, AND FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE CAUSED BY THEIR WORK OR ANY SUBCONTRACTOR.
SCHEDULING
THE GC SHALL MEET WITH THE OWNER'S AUTHORIZED REPRESENTATIVE WELL IN ADVANCE OF CONSTRUCTION COMMENCEMENT TO:A. SCHEDULE, SEQUENCE AND COORDINATE ALL WORKB. MAINTAIN EXITS AND EGRESS WIDTHS REQUIRED BY CODES DURING ALL PHASES OF CONSTRUCTION.
TRUE NORTH
HOPEWELL COMMUNITY CENTER
AUGUST 27, 2021
ISSUE DESCRIPTION
FILENAME
SCALE
SHEET
PROJECT NUMBER
BRIAN MELI
COMMUNITY CENTER POOLSTRUCTURAL COLUMN REPAIRS
FINAL DESIGN (100%)
$D
GN
$
DATE
DESIGN PROJECT MANAGER
SCHEDULE OF SPECIAL INSPECTIONSERVICES
S-2
10311347
AISC CERTIFICATION IS NOT CONSIDERED TO BE FABRICATOR APPROVAL PER SECTION 1704.2.5.1 UNLESS SPECIFICALLY APPROVED BY THEOWNER, IN LIEU OF, OR UNTIL SUCH APPROVAL IS GRANTED, SPECIAL INSPECTION PROVISIONS FOR STRUCTURAL STEEL SHALL BE CONSIDERED TOBE APPLICABLE TO THOSE COMPONENTS FABRICATED AND/OR ASSEMBLED IN THE FABRICATION SHOP.
TESTING AND INSPECTION REPORTS SHALL BE PREPARED FOR EACH INSPECTION ITEM ON A DAILY BASIS WHENEVER WORK IS PERFORMED ONTHAT ITEM. REPORTS SHALL BE DISTRIBUTED TO THE CONTRACTOR, OWNER'S CONSTRUCTION REPRESENTATIVE, BUILDING OFFICIAL (IFREQUESTED), AND ARCHITECT FOR THEIR REVIEW, COMMENT, AND ACTION, AS NEEDED.
THE FOLLOWING SCHEDULE CONTAINS A LIST OF SPECIAL INSPECTION ACTIVITIES RELATED TO THE QUALITY ASSURANCE PLAN REQUIRED BY THEBUILDING CODE (VCC CHAPTER 17) FOR THE FABRICATION, ERECTION AND CONSTRUCTION OF THE STRUCTURAL SYSTEMS AS GIVEN IN THESPECIFICATIONS AND DRAWINGS OF THE PROJECT. ALL INSPECTORS SHALL BE QUALIFIED BY TRAINING AND EXPERIENCE FOR THE REQUIREDINSPECTIONS AND TEST PROCEDURES. REFER TO VCC CHAPTER 17 "STRUCTURAL TESTS AND SPECIAL INSPECTIONS", FOR SPECIFIC TESTPROCEDURES.
QUALIFIED SPECIAL INSPECTORS SHALL BE EMPLOYED PER THE PROVISIONS OF THE CONSTRUCTION CONTRACT TO PERFORM INSPECTIONS INACCORDANCE WITH THE BUILDING CODE. INSPECTORS SHALL PERFORM ALL DUTIES AND RESPONSIBILITIES AS REQUIRED BY THE BUILDING CODE.
TESTING AND INSPECTION SERVICES
SIGNATURE DATE
OWNER NAME
SIGNATURE DATE 8/16/2021
PREPARED BY NAME DAVID LEECHUY
A FINAL REPORT OF SPECIAL INSPECTIONS DOCUMENTING COMPLETION OF THE SPECIFIED SPECIAL INSPECTIONS AND CORRECTION OF ANYDISCREPANCIES, DEFICIENCIES, AND CODE VIOLATIONS SHALL BE SUBMITTED AND APPROVED BY THE OWNER'S CONSTRUCTION REPRESENTATIVEAND THE DESIGN PROFESSIONALS OF RECORD PRIOR TO FINAL INSPECTION.
DISCREPANCIES FROM THE APPROVED PLANS, SPECIFICATIONS, SHOP DRAWINGS, OR DESIGN DIRECTIVES AND CODE VIOLATIONS OBSERVEDDURING THE CONDUCT OF SPECIAL INSPECTIONS SERVICES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FORCORRECTION, TO THE ATTENTION OF THE OWNER'S CONSTRUCTION REPRESENTATIVE, AND TO THE APPROPRIATE DESIGN PROFESSIONAL OFRECORD.
THE SPECIAL INSPECTIONS ENGINEER OF RECORD SHALL KEEP RECORDS OF SPECIFIED SPECIAL INSPECTIONS AND TESTING AND SHALL FURNISHCOPIES OF INSPECTION AND TESTING REPORTS TO THE OWNER'S CONSTRUCTION REPRESENTATIVE AND TO THE APPROPRIATE DESIGNPROFESSIONALS OF RECORD UPON REQUEST. DETAILED SUMMARIES OF ALL SPECIAL INSPECTION ACTIVITIES, FINDINGS, DEFICIENCIES, ANDDISCREPANCIES SHALL BE FURNISHED TO THE OWNER'S CONSTRUCTION REPRESENTATIVE AND TO THE APPROPRIATE DESIGN PROFESSIONALS OFRECORD AT INTERVALS NOT EXCEEDING 1 WEEK.
THIS STATEMENT OF SPECIAL INSPECTIONS IS PREPARED IN ACCORDANCE WITH SECTION 1704 OF THE 2018 VIRGINIA CONSTRUCTION CODE (VCC).IT INCLUDES A SCHEDULE OF SPECIAL INSPECTIONS APPLICABLE TO THIS PROJECT.
REPRESENTATIVE NAME:
GENERAL CONTRACTOR NAME:
COMPANY
GEOTECHNICAL ENGINEER OF RECORD (GEOR) NAME: N/A LICENSE:
COMPANY HDR INC STATE OF VIRGINIA
STRUCTURAL ENGINEER OF RECORD (SEOR) NAME: GONZALO KOOSAU LICENSE: PE # 0402040675
COMPANY
ARCHITECT OF RECORD (AOR) NAME: N/A LICENSE:
BUILDING OWNER OR OWNER'S AGENT
PROJECT LOCATION 100 W. CITY POINT RD, HOPEWELL, VA 23860
STRUCTURE NAME COMMUNITY CENTER POOL
PROJECT NAME STRUCTURAL COLUMN REPAIRS
STATEMENT OF SPECIAL INSPECTIONS
INSPECT VAPOR RETARDER FORCONFORMANCE WITH MANUFACTURESWRITTEN INSTALLATION INSTRUCTIONS
● SEC 03 05 00
TESTING AND EVALUATION OF IN-PLACEDENSITY OF COMPACTED FILL AS WORKPROGRESSES
● VCC 1705.6ONE DENSITY TEST FOR EACH LIFT, DAYSOPERATION, OR 5000 SQ. FT. OF FILL AREA
VERIFY USE OF PROPER MATERIALS, ANDLIFT THICKNESSES DURING PLACEMENT ANDCOMPACTION OF COMPACTED FILL
● SEC 03 05 00 VCC 1705.6ONE DENSITY TEST FOR EACH LIFT, DAYSOPERATION, OR 5000 SQ. FT. OF FILL AREA
PERFORM CLASSIFICATION AND TESTING OFCONTROLLED FILL MATERIAL ● SEC 03 05 00 VCC 1705.6 TEST EACH SOURCE
VERIFY EXCAVATIONS ARE EXTENDED TOPROPER DEPTH AND HAVE REACHEDPROPER MATERIAL
● VCC 1705.6ALL FOOTING AND PILE CAP EXCAVATIONS SHALL BEOBSERVED AND APPROVED PRIOR TO CONCRETEPLACEMENT
EARTHWORK, SHALLOW FOUNDATIONS AND SOIL
CONDUCT WEEKLY VISUAL OBSERVATIONSOF THE STRUCTURAL SYSTEMS FORGENERAL CONFORMANCE TO THECONSTRUCTION DOCUMENTS AND PREPAREWEEKLY REPORTS OF OBSERVATIONSDESCRIBING WORK PROGRESS ANDNON-CONFORMING ITEMS
● VCC 1704.2.4
GENERAL
CONTINUOUS PERIODIC SECTION REFERENCE
INSPECTION ITEM REQUIRED FREQUENCY SPECIFICATI... CODE REMARKS
SCHEDULE OF SPECIAL INSPECTION SERVICES
EACH PASS MEETS QUALITY REQUIREMENTS ●
EACH PASS WITHIN PROFILE LIMITATIONS ●
INTERPASS AND FINAL CLEANING ●
WELDING TECHNIQUES
AISC 360 TABLEN5.4-2
AWS D1.1
PROPER POSITION (F, V, H, OH) ●
INTERPASS TEMPERATURE MAINTAINED ●
PREHEAT APPLIED ●
SHIELDING GAS TYPE/FLOW RATE ●
SELECTED WELDING MATERIALS ●
TRAVEL SPEED ●
SETTINGS ON WELDING EQUIPMENT ●
WPS FOLLOWED
ENVIRONMENTAL CONDITIONS (WIND SPEEDWITHIN LIMITS, PRECIPITATION & TEMPERATURE) ●
NO WELDING OVER CRACKED TACK WELDS ●
CONTROL AND HANDLING OF WELDINGCONSUMABLES (PACKAGING, EXPOSURE CONTROL) ●
USE OF QUALIFIED WELDERS ●
AISC 360 TABLEN5.4-2
AWS D1.1
WELDERS MUST BE CERTIFIED UNDER AWSQUALIFICATION PROCEDURES
INSPECTION TASKS DURING WELDING
TACKING (TACK WELD QUALITY ANDLOCATION) ●
CLEANLINESS (CONDITION OF STEELSURFACES) ●
DIMENSIONS (ALIGNMENT, GAPS AT ROOT) ●
FIT UP OF FILLET WELDS
CONFIGURATION AND FINISH OF ACCESS HOLES ●
BACKING TYPE AND FIT (IF APPLICABLE) ●
TACKING (TACK WELD QUALITY ANDLOCATION) ●
CLEANLINESS (CONDITION OF STEELSURFACES) ●
DIMENSIONS (ALIGNMENT, ROOT OPENING,ROOT FACE, BEVEL) ●
JOINT PREPARATION ●
FIT UP OF GROOVE WELDS (INCLUDING JOINTGEOMETRY)
WELDER IDENTIFICATION SYSTEM ●FABRICATOR OR ERECTOR SHALLMAINTAIN A SYSTEM BY WHICH A WELDERWHO HAS WELDED A JOINT OR MEMBERCAN BE IDENTIFIED.
MATERIAL IDENTIFICATION (TYPE/GRADE) ●
MANUFACTURER'S CERTIFICATIONS FORWELDING CONSUMABLES AVAILABLE ●
INCLUDES ELECTRODES, FLUXES ANDSHIELDING GASES. DEMAND CRITICALWELDS SHALL HAVE FILLER MATERIALSTHAT MEET NOTCH TOUGHNESSREQUIREMENTS.
WELDING PROCEDURE SPECIFICATIONS (WPS)AVAILABLE ●
AISC 360 TABLEN5.4-1
AWS D1.1
INSPECTION TASKS PRIOR TO WELDING
VERIFY MATERIALS CONFORM TO ASTM STANDARDSSPECIFIED IN THE CONSTRUCTION DOCUMENTS ● SEC 05 12 00
VCC 1706.1AISC 360 N5.2
VERIFY CORRECT STRUCTURAL STEEL MATERIALDELIVERED TO JOB SITE. ● SEC 05 12 00 AISC 360 N5.2
VISIT FABRICATION SHOP TO OBSERVE FABRICATIONPROCEDURES. ● VCC 1705.2
ONLY ONE INSPECTION IS REQUIREDUNLESS ON-SITE EVENTS INDICATEFURTHER INSPECTIONS ARE NECESSARY
STRUCTURAL STEEL
PERFORM OBSERVE SECTION REFERENCE
INSPECTION ITEM REQUIRED FREQUENCY SPECIFICATION CODE REMARKS
SCHEDULE OF SPECIAL INSPECTION SERVICES
DOCUMENT ACCEPTANCE OR REJECTION OFEACH WELDED JOINT OR MEMBER ●
PLACEMENT OF REINFORCING OR CONTOURINGFILLET WELDS (IF REQUIRED) ● DOCUMENT ALL ACTIVITIES OF STEEL SFRS
REPAIR ACTIVITIES ● DOCUMENT ALL ACTIVITIES OF STEEL SFRS
BACKING REMOVED, WELD TABS REMOVED ANDFINISHED, AND FILLET WELDS ADDED (IF REQUIRED) ● DOCUMENT ALL ACTIVITIES OF STEEL SFRS
K-AREA ●WHEN WELDING DOUBLER PLATES, CONTINUITY PLATES ORSTIFFENERS IN THE K-AREA, VISUALLY INSPECT WEB K-AREA FORCRACKS WITHIN 3 INCHES OF WELD
ARC STRIKES ●CRACKS OR BLEMISHES CAUSED BY ARC STRIKES SHALL BEGROUND TO A SMOOTH CONTOUR AND CHECKED TO ENSURESOUNDNESS
POROSITY ●
UNDERCUT ●
WELD SIZE ●
WELD PROFILE ●
CRATER CROSS SECTION ●
WELD - BASE METAL FUSION ●
CRACK PROHIBITION ●
WELD MEET VISUAL ACCEPTANCE CRITERIAVISUALLY INSPECT ALL WELDS WITHIN THE ALLOWABLE TIME OFINSPECTION. DOCUMENT ALL ACTIVITIES OF STEEL SFRS
SIZE, LENGTH AND LOCATION OF WELDS ● PROVIDE CONTINUOUS INSPECTION ON ALL WELDS
WELDS CLEANED ●
AISC 360 TABLEN5.4-3
AWS D1.1
WELDED JOINTS SHALL NOT BE PAINTED OR COVERED UNTIL AFTERWELDING IS COMPLETED AND WELD ACCEPTED
INSPECTION TASKS AFTER WELDING
STRUCTURAL STEEL
PERFORM OBSERVE SECTION REFERENCE
INSPECTION ITEM REQUIRED FREQUENCY SPECIFICATION CODE REMARKS
SCHEDULE OF SPECIAL INSPECTION SERVICES
OBSERVE PROPER CURING TEMPERATURE ANDTECHNIQUES ●
ACI 318Ch 26.5.3, 26.5.4,
26.5.5IBC 1705.3
OBSERVE CONCRETE PLACEMENT ●ACI 318
Ch 26.5.2IBC 1705.3
MAINTAIN A SPREADSHEET SHOWING DATE,SEQUENTIAL ORDER OF STRENGTH TEST RESULTS,AND INDICATE RUNNING AVERAGE
●ACI 318
Ch 26.11.2(d),26.11.2(e)
PERFORM CONCRETE STRENGTH TESTING ●ASTM C172ASTM C31
ACI 318 Ch 26.4,26.5.3, 26.12IBC 1705.3
SAMPLE CONCRETE SPECIMENS PRIOR TOPLACEMENT FOR STRENGTH TESTS TO BEPERFORMED IN LAB. A MINIMUM OF FIVE (5)CYLINDERS SHALL BE MADE. TEST TWO AT 7 DAYSAND TWO AT 28 DAYS. THE 5TH CYLINDER SHALL BEHELD IN RESERVE
●ASTM C172ASTM C31
ACI 318 Ch 26.4,26.5.3, 26.12IBC 1705.3
ADDITIONAL CYLINDERS SHALL BE MADE AS NEEDEDFOR EARLY FORM REMOVAL, TWO 6X12 OR THREE 4X8CYLINDERS ARE REQUIRED FOR AN ACCEPTABLE TEST.SINGLE CYLINDER TEST IS INADEQUATE FOR STRENGTHEVALUATION PURPOSES
SAMPLE FRESH CONCRETE PRIOR TO PLACEMENT.MEASURE SLUMP, AIR CONTENT, AND TEMPERATUREDURING CONCRETE DELIVERY.
●ASTM C172ASTM C31
ACI 318 Ch 26.4,26.5.3, 26.12IBC 1705.3
ADDITIONAL CYLINDERS SHALL BE MADE AS NEEDEDFOR EARLY FORM REMOVAL, TWO 6X12 OR THREE 4X8CYLINDERS ARE REQUIRED FOR AN ACCEPTABLE TEST.SINGLE CYLINDER TEST IS INADEQUATE FOR STRENGTHEVALUATION PURPOSES
VERIFY USE OF CORRECT CONCRETE MIX DESIGNAND REVIEW DELIVERY TICKETS ● ACI 318
Ch 26.4
INSPECT POST-INSTALLED ANCHORS INSTALLEDHORIZONTALLY OR UPWARD. VERIFY PLACEMENTLOCATION AND INSTALLATION PROCEDURES.
●ACI 318
Ch 17.8.2, 26.7.1,26.7.2
IBC 1705.3
OBSERVE AND VERIFY PLACEMENT OF OTHEREMBEDMENTS CAST IN CONCRETE PRIOR TOCONCRETE PLACEMENT
● ACI 318Ch 26.8
VISUAL INSPECTION OF ALL EMBEDMENTS
OBSERVE AND VERIFY PLACEMENT OF ANCHORS,BOLTS, AND RODS CAST IN CONCRETE PRIOR TOCONCRETE PLACEMENT
●ACI 318
Ch 17.8.2, 26.7.1IBC 1705.3
VISUAL INSPECTION OF ALL BOLTS
VERIFY CORRECT MATERIAL USED, INCLUDING THEUSE OF A706 IN WELDED SPLICES, IF ANY ●
AWS D1.4ACI 318 Ch 26.6.4
IBC 1705.3
INSPECT REINFORCING STEEL PRIOR TO CLOSING OFTHE FORMS AND ARRIVAL OF CONCRETE TO THEJOBSITE. VERIFY PLACEMENT.
● SEC 03 05 00
ACI 318Ch 20, 25.2, 25.3,
26.6.1, 26.6.2, 26.6.3IBC 1705.3
CONCRETE AND REINFORCING STEEL
CONTINUOUS PERIODIC SECTION REFERENCE
INSPECTION ITEM REQUIRED FREQUENCY SPECIFICATION CODE REMARKS
SCHEDULE OF SPECIAL INSPECTION SERVICES
G
22
F D C B A
33
44
66
8
1111
14
1515
1616
HJ
13
10
7
16' -
0"
16' -
0"
24' -
0"
18' -
3"
18' -
3"
18' -
3"
18' -
3"
8' -
0"
16' -
0"
16' -
0"
24' -
0"
8' -
3"
23' -
1"
5' -
2"
16' -
10"
19' -
8"
8' -
0"
22' - 0" 22' - 0" 22' - 0" 22' - 0" 22' - 0"
1' - 2"
EXIST. SWIMMING POOL
COLUMN
EX. HSS8X8X1/2
COLUM
N
EX. HSS8X
8X1/
2
COLUM
N
EX. HSS8X
8X1/
2
COLUM
N
EX. HSS8X
8X1/
2
COLUMN
EX. HSS8X8X1/4
COLUMN
EX. HSS8X8X1/4
COLUMN
EX. HSS8X8X1/4
COLUMN
EX. HSS8X8X1/4
COLUMN
EX. HSS8X8X1/4
COLUMN
EX. HSS8X8X1/2
COLUMN
EX. HSS8X8X1/2
COLUMN
EX. HSS8X8X1/2
COLUMN
EX. HSS8X8X1/4
COLUMN
EX. HSS8X8X1/4
COLUMN
EX. HSS8X8X1/4
FINISHED FLOOR EL. = 50'-6"
TRANSLUCENT WALL PANEL
EXIST. GLASS DOOR WITH
TRANSLUCENT WALL PANEL
EXIST. GLASS DOOR WITH
DOOR
EXISTING
EXIST. ALUMINUM GLASS STOREFRONT
DO
OR
EX
IST
ING
DO
OR
EX
IST
ING
9' -
4"
5' -
2"
DOOR
EXISTING
DO
OR
EX
IST
ING
ST
OR
EF
RO
NT
EX
IST
ING
1
5
6789
10
11
12
13
14 15 4 3
2
2
S-3
TYP. EXISTING SLAB ON GRADE AT POOL DECK
EXISTING STEEL COLUMN
EXISTING CONCRETE PIER
EXISTING FOOTING
EXISTING EXTERIOR CMU WALL
8"
4"
GR
OU
T
1"
3
S-3
FINISHED FLOOR
0'-0"
EXISTING CONCRETE PIER
EXISTING 3/4" THK BASE PLATE WITH (4) 3/4" DIA. ANCHOR BOLTS
EXISTING STEEL COLUMN
CL
CL
ISSUE DESCRIPTION
FILENAME
SCALE
SHEET
PROJECT NUMBER
BRIAN MELI
COMMUNITY CENTER POOLSTRUCTURAL COLUMN REPAIRS
FINAL DESIGN (100%)
$D
GN
$
DATE
DESIGN PROJECT MANAGER
As indicated
COLUMN LOCATION PLAN
S-3
10311347
TRUE NORTH
NOTES:
1. FINISHED FLOOR ELEVATION = 0'-0" +/- ON PLAN UNLESS NOTED OTHERWISE. ELEVATION 0'-0" CORRESPONDS TO DATUM ELEVATION 50'-6".
2. EXISTING FLOOR SLAB IS 4" CONCRETE REINFORCED WITH 6X6XW10XW10 WELDED WIRE. REINFORCEMENT IS 1" CLEAR FROM TOP OF SLAB.
3. TOP OF EXISTING CONCRETE PIER ELEVATION = (-0'-8") UNLESS NOTED OTHERWISE.
4. DENOTES COLUMN NUMBER. SEE SHEET S-5 AND S-6 FOR PHOTOS OF COLUMN CORROSION AND DAMAGE.
EXIST. CONCRETE FOOTING
EXIST. STEEL COLUMN,SEE PLAN
SPREAD FOOTING WITH STEEL COLUMN
EXIST. CONCRETE PIER
1" = 1'-0" 2TYPICAL EXISTING COLUMN, PIER AND FOOTING DETAIL
1" = 1'-0" 3TYPICAL EXISTING BASE PLATE DETAIL
X
FINISHED FLOOR
CL
1' - 0" 1' - 0"
1' -
0"
EXISTING
COLUMN TO BE
REPAIRED
EXTENT OF SLAB
DEMOLITION
1-INCH CORES AT CORNER
PRIOR TO SAWCUT TO
PREVENT OVERCUTTING.
EXISTING
MASONRY WALL
TO REMAIN. DO
NOT DAMAGE.
CL
REBAR DOWELS INTO
EXISTING CONCRETE
NEW CONCRETE INFILL.
APPLY CONCRETE DECK
COATING
3/8 THK PREMOLDED
JOINT FILLER
REINFORCED STEEL
COLUMN. SEE
FOR MULTIPLE CASES.
6" 6"
8
S-4
1S-4
4
S-4
EXISTING STEEL COLUMN
EXISTING CONCRETE PIER
STEEL REINFORCEMENT. SEE
FOR MULTIPLE CASES.
3/16
NOTES:
1. STEEL REINFORCEMENT TO
COMPLETELY ENCLOSE DAMAGED AREA.
2. EXTEND REINFORCEMENT 6" MINIMUM
ABOVE PAST DAMAGED AREA, AND
BELOW TO TOP OF BASEPLATE. WELD
REINFORCEMENT TO SOUND COLUMN
METAL.
1
S-4
1S-4
FINISHED FLOOR
0'-0"
TOP OF COATING
1'-6"
NEW COATING REQUIRED, 3 SIDES
EXPOSED TO POOL DECK
EXIST. SLABNEW SLAB
7/S-4
3/8 THK PLATE FACE
REINFORCEMENT3/16
TYP
L ANGLE CORNER
REINFORCEMENT,
EACH CORNER
CL
L2X2X3/8 OR L3X3X3/8
CORNER REINFORCEMENT.
REINFORCE ONLY AT
CORNER WHERE DAMAGE
OCCURS.
3/16TYP
CASE A
CASE B
CASE C
DAMAGE, TYP.
DAMAGE, TYP.
DAMAGE, TYP.
3" 3"
2
S-4
2
S-4
2
S-4
SIM.
TYP.
SIM.
FACE PLATE
REINFORCEMENT
9
S-4
PREMOLDED JOINT FILLER
WITH SEALANT AS INDICATED
OR SPECIFIED, TYPICAL
EXIST SLAB
ON GRADE
NEW SLAB
INFILL
#3 ADHESIVE DOWELS.
SEE PLAN FOR LAYOUT
TYP
6"
VAPOR RETARDER COMPACTED GRANULAR FILL OVER
EXISTING SUBGRADE. COMPACT TO
95% MAXIMUM DRY DENSITY.
T/2
MA
TC
H E
XIS
TIN
G
T =
SLA
B T
HIC
KN
ES
S
EXIST CMU WALL
4
"
6X6XW2.1XW2.1
NOTES:
1. COLUMN REPAIR SCHEDULE IS BASED ON COLUMN CONDITIONS AT TIME OF
INVESTIGATION. SEE SHEET S-5 AND S-6.
2. SEE DETAIL AND WHERE REINFORCEMENT IS REQUIRED.
SEE DETAIL WHERE ONLY COATING IS REQUIRED.
3. AFTER PREPARING STEEL COLUMN PER SPECIFICATIONS, OBSERVE, INSPECT
AND VERIFY COLUMN CONDITIONS. ADDITIONAL REPAIR MAY BE REQUIRED
WHERE COLUMN CORROSION OR DAMAGE EXCEEDS THE CONDITIONS SHOWN
ON S-5 AND S-6. NOTIFY OWNER AND STRUCTURAL ENGINEER
4. REINFORCE ALL COLUMNS EXHIBITING THROUGH-THICKNESS DAMAGE.
5. SEE SHEET S-3 FOR COLUMN PLAN LOCATIONS.
1S-4
4S-4
5S-4
EXISTING STEEL COLUMN
EXISTING CONCRETE PIER
FINISHED FLOOR
0'-0"
TOP OF COATING
1'-6"
NEW COATING, 3 SIDES
EXPOSED TO POOL DECK
EXIST POOL DECK SLAB TO
REMAIN
COLUMN REINFORCEMENT. SEE
FOR MULTIPLE CASES.
COMPLETELY COVER DAMAGED AREA.
WELD ONLY TO SOUND COLUMN METAL.
EXISTING STEEL COLUMN
3/16
MIN6"
3/16
1S-4
DAMAGED AREA
EXIST. COLUMN
FRONT PIPE COVER ATTACHED
TO STEEL COLUMN. REPLACE
SCREWS CONNECTING TO THE
STEEL COLUMN WITH STAINLESS
STEEL SCREWS WITH PLASTIC
SPACERS BETWEEN THE STEEL
COLUMN AND PIPE COVER.
BASEBOARD HEATERS.
REMOVE COVER AND
PIPING AS REQUIRED TO
COMPLETE REPAIR WORK.
COORDINATE WITH SEQUENCING OF
WORK AS OUTLINED ON SHEET S-1.
3/16ANGLE TO HSS
PJP, PLATE TO ANGLE
PJP, PLATE TO ANGLE
BEVEL PLATE,
TYP.
GROUND SURFACE
SMOOTH, TYP.
ISSUE DESCRIPTION
FILENAME
SCALE
SHEET
PROJECT NUMBER
BRIAN MELI
COMMUNITY CENTER POOLSTRUCTURAL COLUMN REPAIRS
FINAL DESIGN (100%)
$D
GN
$
DATE
DESIGN PROJECT MANAGER
As indicated
SECTIONS AND DETAILS
S-4
10311347
1" = 1'-0" 6TYPICAL SLAB DEMOLITION - PLAN
1" = 1'-0" 7TYPICAL SLAB INFILL AROUND EXISTING COLUMN - PLAN
1" = 1'-0" 4TYPICAL SECTION - COLUMN REINFORCEMENT - SECTION
1 1/2" = 1'-0" 1TYPICAL COLUMN REINFORCEMENT - PLAN
15 HSS 8x8x1/2 NOT REQUIRED - REQUIRED
14 HSS 8x8x1/2 REQUIRED B REQUIRED
13 HSS 8x8x1/2 REQUIRED A REQUIRED
12 HSS 8x8x1/4 NOT REQUIRED - REQUIRED
11 HSS 8x8x1/4 REQUIRED B REQUIRED
10 HSS 8x8x1/4 REQUIRED C REQUIRED SLAB ALREADY DEMOLISHED FROM PREVIOUS INVESTIGATION
9 HSS 8x8x1/2 NOT REQUIRED - REQUIRED
8 HSS 8x8x1/2 REQUIRED B REQUIRED
7 HSS 8x8x1/2 NOT REQUIRED - REQUIRED
6 HSS 8x8x1/4 NOT REQUIRED - REQUIRED
5 HSS 8x8x1/4 NOT REQUIRED - REQUIRED
4 HSS 8x8x1/2 REQUIRED B REQUIRED SLAB ALREADY DEMOLISHED FROM PREVIOUS INVESTIGATION
3 HSS 8x8x1/4 NOT REQUIRED - REQUIRED
2 HSS 8x8x1/4 REQUIRED B REQUIRED
1 HSS 8x8x1/4 REQUIRED B REQUIRED SLAB ALREADY DEMOLISHED FROM PREVIOUS INVESTIGATION
NUMBER SIZE REINFORCEMENT REINFORCEMENT CASE COATING REMARKS
COLUMN REPAIR SCHEDULE
3/4" = 1'-0" 8TYPICAL - SLAB ON GRADE
1" = 1'-0" 5TYPICAL SECTION - COLUMNS REQUIRING COATING ONLY
1" = 1'-0" 2TYPICAL COLUMN REINFORCEMENT - ELEVATION
3" = 1'-0" 3TYPICAL EXISTING COLUMN
6" = 1'-0" 9COLUMN REINFORCEMENT - ENLARGED PLAN